Home
ADAM-5000 Series Manual.book
Contents
1. User Manual ADAM 6100El Series EtherNet IP 1 0 Modules AD ANTECH eAutomation Copyright The documentation and the software included with this product are copyrighted 2009 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Product Warranty 2 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advant
2. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel The power cord or plug is damaged Liquid has penetrated into the equipment The equipment has been exposed to moisture The equipment does not work well or you cannot get it to work according to the user s manual The equipment has been dropped and damaged The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS The sound pressure level at the operator s p
3. ADAM 6100El Series User Manual 2 2 Relay Modules 2 2 1 Overview The ADAM 6160EI is a relay module which supports EtherNet IP protocol It provides six Form C relay channels and is excellent for ON OFF control or low power switch ing applications in an EtherNet IP system ADAM 6160El 6 ch Relay Module Data Acquisition Modules ADAM 6160EI Figure 2 4 ADAM 6160El 2 2 2 Specifications Relay Channels 6 Form C Contact Rating AC 250V 5A DC 30V 5A Breakdown Voltage 500 VAC 50 60 Hz Mechanism 20 000 000 operations Relay on time 7 ms Relay off time 3 ms Contact Resistance 30 mQ max Insulation Resistance 1 GO at 500 Vic General Communication 10 100 Base T Ethernet Supports Protocol Ethernet IP Power Input Unregulated 10 30 Vpc Power Consumption 3 5 W 24 Vic Power Reversal Protection Operating Humidity 20 95 RH non condensing Storage Humidity 0 95 RH non condensing Operating Temperature 10 70 C ADAM 6100El Series User Manual 10 M Storage Temperature 20 80 C 11 ADAM 6100El Series User Manual ADAM 6100El Series User Manual 12
4. N C not used 6 RD Receive 7 N C not used 8 N C not used 1 3 2 2 500V Isolation Protection With triple isolation including power supply input output and Ethernet communica tion ADAM 6100El series ensures I O data to be controlled correctly and prevents devices from breaking down Communication Input Output 3 ADAM 6100El Series User Manual 1 3 3 Ethernet based Configuration Tool You can configure ADAM 6100EI module as Initial mode or Normal mode by the DIP switch in the side of each module Refer to figure below for how to configure it When ADAM 6100EI module is set as Initial mode you can use ADAM Net utility to config ure and test the module via Ethernet connection between PC and the module This can ensure the ADAM 6100EI module is set properly and is working correctly before connecting it to an EtherNet IP network When ADAM 6100EI module is set as Nor mal mode it can directly communicate with EtherNet IP master device such as Allen Bradley PLC by EtherNet IP protocol Normal Note The default mode is the utility mode ADAM 6100El Series User Manual 4 Chapter 2 Product Specifications 2 1 Digital I O Modules 2 1 1 Overview The ADAM 6150El ADAM 6151EI and ADAM 6156EI are a series of isolated digital I O modules which support the EtherNet IP protocol According to the channel number dif ference you can choose the best digital I O modules for your application M
5. Product name and serial number Description of your peripheral attachments Description of your software OS version application software etc A complete description of the problem The exact wording of any error messages Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components iii ADAM 6100El Series User Manual Safety Instructions 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Read these safety instructions carefully Keep this User Manual for later reference Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equip ment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS
6. ech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid
7. i ADAM 6150EI 8 ch isolated digital input and 7 ch isolated digital output module Mi ADAM 6151EI 16 ch isolated digital input module Mi ADAM 6156EI 16 ch isolated digital output module Figure 2 1 ADAM 6150El Figure 2 2 ADAM 6151El ADAM 6100El Series User Manual 6 Figure 2 3 ADAM 6156EI 2 1 2 Specifications Digital Input Channels ADAM 6150EI 8 ADAM 6151El 16 Dry Contact Logic level 0 Open Logic level 1 Close to Ground Wet Contact Logic level 0 0 3 Vic Logic level 1 10 30 Vic Input Impedance 10 kohm Transition Time 0 2 ms Digital Output Channels ADAM 6150El 7 ADAM 6156EI 16 Output Voltage Range 8 35 Vic Normal Output Current 100 mA per channel 7 ADAM 6100El Series User Manual General Communication 10 100 Base T Ethernet Supports Protocol EtherNet IP Power Input Unregulated 10 30 Vic Power Consumption 2 4 W 24 Vic Power Reversal Protection Operating Humidity 20 95 RH non condensing Storage Humidity 0 95 RH non condensing Operating Temperature 10 70 C Storage Temperature 20 80 C 2 1 3 Application Wiring Isolated Digital Input Dry Contact Dry Contact Isolated Digital Input Wet Contact Wet Contact 0 30Vpe DI COM ADAM 6100El Series User Manual 8 Isolated Digital Output ADAM 6150EI 10 MV Isolated Digital Output ADAM 6156EI 10 30Voc OTG 9
8. ll ADAM 6100El series mod ules can comply with it You can easily connect ADAM 6100EI modules to EtherNet IP masters like Allen Bradley PLC through EtherNet IP protocol ADAM 6100EI series module supports Initial mode and Normal mode EtherNet IP mode that you can set by the DIP switch on the side of ADAM module Refer to Section 1 3 3 for how to configure it When you configure the mode as Initial mode you can configure ADAM 6100EI module s IP address and related setting by Advantech APAX ADAM Net utility When you configure the mode as Normal mode ADAM 6100EI modules are ready to communicate with EtherNet IP master by EtherNet IP protocol System Architecture ADAM 6100El series modules can be daisy chained in an Ethernet network making it easier to deploy and helping improve scalability You can refer to the figure below to see how a daisy chain connection works in the network Figure 1 1 ADAM 6100El Daisy Chain Connections ADAM 6100El Series User Manual 2 1 3 Features 1 3 1 Daisy Chain Connection ADAM 6100EI module has built in Ethernet switches to allow daisy chain connections in an Ethernet network making it easier to deploy and helping improve scalability The two Ether net ports are fully compliant with IEEE 802 3u 10 100Mbpst through standard RJ 45 connectors 100m 100m 1 i Pin Assignment Description 1 TD Transmit 2 TD Transmit 3 RD Receive 4 N C not used 5
9. osition according to IEC 704 1 1982 is no more than 70 dB A DISCLAIMER This set of instructions is given according to IEC 704 1 Advantech disclaims all responsibility for the accuracy of any statements contained herein ADAM 6100El Series User Manual iv Chapter Chapter 1 Ni 2 1 2 2 Overview asrannvannnannnannnannnnnnnvannvnvnvnvnenen 1 Introduction siano 2 System Architecture eee eeceeeeeeeeeaeeeeeeeeaeeeeeeenaeeeeeeenaeeeeenenaaes 2 Figure 1 1 ADAM 6100EI Daisy Chain Connections 2 Featur s nnii iii iii 3 1 3 1 Daisy Chain Connection 3 1 3 2 2 500V Isolation Protection 3 1 3 3 Ethernet based Configuration Tool 4 Product Specifications d Digital O Modules 6 ZAM OVETVIEW iena da 6 Figure 2 1 ADAM 6150El 6 Figure 2 2 ADAM 6151El 6 Figure 2 3 ADAM 6156El nn 7 24 2 SPECINCAIONS rss res lia ira 7 2 1 3 Application Wiring 8 Relay Modules Sii A 10 2 2 1 E OVET EAV E 10 Figure 2 4 ADAM 6160El 10 2 2 2 Specifications 10 V ADAM 6100El Series User Manual ADAM 6100El Series User Manual vi Chapter 1 Overview 1 1 1 2 Introduction ADAM 6100El is a series of EtherNet IP remote I O modules EtherNet IP protocol is very popular in industrial automation applications and a
10. to your dealer Part No 2003610000 Edition 1 Printed in Taiwan May 2011 ADAM 6100El Series User Manual ii Declaration of Conformity CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring We recommend the use of shielded cables This kind of cable is available from Advantech Please contact your local supplier for ordering information FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance 1 Visit the Advantech web site at www advantech com support where you can find the latest information about the product 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call
Download Pdf Manuals
Related Search
Related Contents
対照表 - 奈良県 Hamilton Beach Commercial coffeemaker User's Manual YAP User`s Manual - Universidade do Porto 吹田市立武道館 指定管理者管理運営基準 平成27年7月1日 吹田市 Manuel de référence FB107 - Welcome to Emerson Process Management Documentation Appendix A - AutomationDirect GE BR Series Installation Guide User manual - Spy Cameras Copyright © All rights reserved.