1. Suction Unit FAZZINI y Your Health is our aim F 3 1 Service Manual NOTE This manual is related to the following Equipment Suction Pump F 31 C C Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 1 of 12 Suction Unit m Health is our aim F _ 3 1 Service Manual All equipment and accessories should be in good working order prior to use It is the responsibility of each facility s engineering department to test equipments and routine basis to determine if the devices are functioning within specifications No device or accessory should be used if a malfunction is suspected The installation operation search for breakdowns and the repair of equipment must only be performed by trained personnel who have sufficient knowledge about the equipment spare parts and the information supplied CAUTIONS BEFORE STARTING TO INSPECT THE DEVICE MAKE SURE IT IS NOT CONNECTED TO THE ELECTRIC POWER SUPPLY NETWORK DO NOT USE THE APPLIANCE IN THE PRESENCE OF INFLAMMABLE AND OR EXPLOSIVE LIQUIDS GASES OR MIXTURES DO NOT LEAVE THE APPLIANCE EXPOSED TO ATMOSPHERIC AGENTS OR HEAT SOURCES USING THE APPLIANCE UNDER DIFFERENT CONDITIONS THAN THOSE SPECIFIED IN THIS HANDBOOK MAY PREJUDICE ITS SAFETY AND ITS TECHNICAL PARAMETERS DELIVERY AND UNCRATING OF UNIT Inspect equipment and shipping crate immediately upon receipt If any damage is apparent you should both report it to the trucki
2. 6 SuctioncatheterCH14 7 Mainswith 8 Vacuum regulator 9 Vacuum gauge Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 8 of 12 Suction Unit yw EP AAZAINI y y Your Health is our aim F _ 3 1 Service Manual General assembly F 31 xx 05 0006 Autoclavable 05 00062 Disposable N 05 0015 05 0055 Autoclavable set 05 00552 Disposable set a 05 0005 Autoclavable 05 00052 aub 1LT 05 0001 2LT 05 0002 217 0217 03 2507 SP 38 02 SP 20 00 N 09 000 SP 30 01 SP 03 00 Back case SP 42 08 SP 03 01 Onlv for suction pump with trolley Front case Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 9 of 12 Your Health is our aim F E 3 1 Service Manual Functional layout Suction Unit By razzriwi yy Main External plug 230V AC BLUE i BROWN External plug 12V DC 98 Yellow Green Ground G Control Board 00000 Pin Lighter Schema elettrico F 31 1 dwg Wiring External plug 230V BLUE m WN Motor t External plug 12V DX Battery Battery charger I on charoe Rocker switt h Yellow Green Brown Negative pole Control Boar Pin Lighter Schema elettrico F 31 1 dwg Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 10 of 12 Suction Unit By razzriwi F y Your Health is our aim F _ 3 1 Service Manual Pneumatic ci
3. VARIED WITH THE RELEVANT CONTROL ON THE FRONT PANEL OF THE APPLIANCE 8 AND CAN BE CHECKED ON THE APPLIANCE FRONT PANEL 9 VACUOMETER 9 1T IS RECOMMENDED TO CARRY OUT A FIRST ASPIRATION CYCLE WITH AT LEAST 500 ML OF WATER ONLY 10 THE ASPIRATED FLUID WILL FLOW IN THE RELEVANT JAR SHOULD THE AMOUNT OF FLUID EXCEED THE JAR S CAPACITY THE OVERFLOW VALVE WILL STOP ASPIRATION 11 IMMEDIATELY SWITCH OFF THE APPLIANCE BY SETTING THE ON OFF 7 SWITCH ON THE OFF POSITION Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 5 of 12 _ Suction Unit s Health is our aim F _ 3 1 Service Manual INDICATORS LED The suction unit F 31 XX is equipped with light indicators led signaling the battery use because using the appliance on a low battery may damage the appliance itself while continuously recharging it does not cause any damage It is recommended to always check the battery s recharge level LIGHT INDICATOR DESCRIPTION OF THE BATTERY LEVEL LED ON GREEN MAXIMUM CHARGE 2 LED ON YELLOW MEDIUM CHARGE 3 LED ON YELLOW LOW CHARGE 4 LED ON RED NEEDS RECHARGE 5 LED NEXT TO THE BATTERY S CHARGE WHEN THIS LED IS ON IT SHOWS THAT RECHARGE IS LEVEL INDICATORS RED UNDERWAY 1 1 2 3 4 5 ON C HARG F 100 95 MEDIUM NW NEEDS RECHARGE feeding ok Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 6 of 12 _ Suction Unit s Health is our aim F _ 3 1 Service Manual PERIODIC MAINTENANCE CHECK SUCT
4. ATE ON AN EXTERNAL 12 V BATTERY USING THE APPROPRIATE CABLE WITH CAR PLUG Battery change 1 Detach the connections A on the blue and brown wires 2 Unscrew the screws B 3 Raise the slab C 4 Replace the battery 5 Fix the slab C with the screws B 6 Connect the threads verifying the correspondence of the colors Blue on positive pole Brown on negative pole Service Manual F 31 doc Rev 2 12 APR 2006 Page 4 of 12 _ Suction Unit s Health is our aim F _ 3 1 Service Manual OPERATING The appliance is a portable SUCTION UNIT FOR EMERGENCY USE MINOR SURGERY AND aimed at freeing the airways from organic secretions OPERATIONAL TEMPERATURE BETWEEN 0 AND 50 RECOMMENDED RECHARGE TEMPERATURE BETWEEN 15 AND 30 OPERATIONAL HUMIDITY BETWEEN 20 AND 90 RU BEYOND 2500 METERS OF HEIGHT THE ASPIRATION FLOW MAY DECREASE THE FOLLOWING STEPS ARE POSSIBLE ONLY IF THE APPLIANCE IS COMPLETELY RECHARGED 1 TIGHTLY SCREW THE LID ON THE JAR TO GUARANTEE A PERFECT SEAL 2 CONNECT THE SHORT TUBE TO FILTER 1 ON THE ASPIRATION 2 VENT 3 CONNECT THE OTHER END OF THE TUBE TO THE VACUUM 3 VENT WITH THE FLOAT ON THE JAR S LID 4 CONNECT THE LONG TUBE 4 TO THE OTHER PATIENT 5 VENT ON THE JAR S LID VENT WITHOUT FLOAT 5 CONNECT THE OTHER END OF THE LONG TUBE 4 TO THE PROBE CONNECTOR 6 AND EVENTUALLY THE SUPPLIED PROBE 7 PRESS THE ON OFF SWITCH 7 8 ASPIRATION INTENSITY CAN BE
5. ION UNIT WAS DESIGNED TO KEEP MAINTENANCE TO A MINIMUM NEVERTHELESS IT IS NECESSARY TO CARRY OUT A DAILY CHECK BEFORE USING THE APPLIANCE BEFORE CARRYING OUT ANY CHECK DUE TO MALFUNCTIONING OR ANOMALIES CALL THE FAZZINI S R L TECHNICAL SERVICE OR PERSONNEL QUALIFIED BY FAZZINI S R L BATTERY CAN BE CHANGED ONLY BY TRAINED PEOPLE FAZZINI S R L DOES NOT OFFER ANY WARRANTY ON APPLIANCE THAT UPON INSPECTION BY THE TECHNICAL SERVICE SHOWS SIGNS OF TAMPERING THE OPERATOR MUST EXCLUSIVELY REPLACE THE SUPPLIED ACCESSORIES IF NECESSARY IN LINE WITH THE APPLIANCE S USE INTENSITY ASPIRATION TUBES SHOULD BE STERILIZED AFTER EACH USE IN CASE OF REPAIR THE USER SHOULD CALL FAZZINI S R L TRANSPORTATION COSTS MUST ALWAYS BE AGREED WITH FAZZINI S R L BEFORE SHIPPING FAILED PIECES SHOULD ANY FLUID LEAK IN THE APPLIANCE CALL THE TECHNICAL SERVICE OF FAZZINI S R L FOR MAINTENANCE DO NOT OPEN THE UNIT STORAGE THE SUCTION UNIT MUST BE STORED IN A DRY LOCATION PROTECTED FROM ATMOSPHERIC AGENTS STORAGE TEMPERATURE BETWEEN 10 AND 55 RELATIVE HUMIDITY BETWEEN 20 AND 80 Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 7 of 12 w FAZZINI F y Your Health is our aim Suction Unit F 31 Legenda F 31 xx Service Manual 1 Filter AT 2 Vacuumdrive 3 Jar drivetothefilter 4 Disposable tube to the patient 5 patient
6. RIAL HYDROPHOBIC FILTER DISPOSABLE Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 3 of 12 Suction Unit E AZZLNEI y y Your Health is our aim F 31 Service Manual BATTERY The units must be recharged when not in use The appliance can be recharged with the appropriate external cable or by placing the appliance on the relevant recharge stirrup BEFORE USING IT FOR THE FIRST TIME IT IS NECESSARY TO KEEP BATTERIES UNDER CHARGE FOR 24 HOURS NON STOP A battery that is constantly under charge lasts about 2 or 3 years After this period of time it is recommended to replace it If the appliance cannot be put under continuous recharge recharge it for 24 hours every 15 days When finished using it the device must always be recharged ATTENTION THE BATTERY MAY BE DAMAGED IF NOT RECHARGED AFTER USE The battery that is completely flat and is not immediately recharged after use must be replaced by the authorized technical assistance When recharging always make sure the warning light on the front panel is on 1 WHEN ON THE DEVICE S DISPLAY ONLY THE RED LED IS ON WHILE THE GREEN LED AND THE TWO YELLOW LED ARE OFF IT IS NECESSARY TO DISCONTINUE OPERATIONS AND RECHARGE THE DEVICE 2 TO CHARGE THE DEVICE KEEP TO THE FOLLOWING INSTRUCTIONS CONNECT THE 230 110V PLUG ON THE BACK OF THE DEVICE THE BLINKING LED SHALL TURN ON SET THE SWITCH ON CHARGE AND KEEP CHARGING FOR AT LEAST 12 HOURS THE DEVICE CAN OPER
7. e Solution The red light flashes in the on off charge positions The power cable is inserted in The red light normally flashes in order to signal the main feeeding the presence of the main feeding Situation Possible Cause Solution The red light is The power cable is off with SW in disconnected to the main the off positions feeeding The red light normally is off when the cable is disconnected to the main feeding Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 12 of 12
8. ng delivery person and contact the transportation company immediately Make notes of any damage on the Bill Of Lading Retain all shipping materials for inspection Any claims for damage must start at the receiving point Do not return goods without written authorization When submitting a claim for shipping damage request that the carrier inspect the shipping container and equipment Check packing slip carefully and make sure all materials have been received as indicated on the packing ticket n An educated qualified person has sufficient knowledge or experience to allow him to avoid the dangers presented by electricity whereas an informed trained person is sufficiently informed or works supervised by qualified persons so as to allow him to avoid the dangers presented by electricity e g operators or maintenance staff Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 2 of 12 Suction Unit y y Your Health is our aim F 3 1 Service Manual TECHNICAL SPECIFICATIONS LENGTH mm 450 WIDTH mm 150 HEIGHT mm 280 WEIGHT kg 4 00 POWER SUPPLY 12V or 110 230V 50 60 Hz MAX VACUUM bar 0 70 MAX FLOW WITH FILTER I mins 10 MAX FLOW DIRECT MEASUREMENT ON ASPIRATION VENT I mins 18 BATTERY code 05 0040 12V 3 3AH FUSES A 2x1 25 ACCESSORIES INCLUDED CODE N DESCRIPTION 05 0001 OR 05 0002 JAR 1000 ML OR 2000 ML 05 00552 SET OF TUBES 05 0010 ASPIRATION PROBE CH 14 DISPOSABLE 05 0016 ANTIBACTE
9. rcuit Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 11 of 12 Suction Unit y y Your Health is our aim F _ 3 1 Service Manual Troobleshooting Situation Possible Cause Solution Disconnected or loose cord Check connections and reconnect unit Faulty wall outlet Use another wall outlet Check the fuses inside SP 38 02 If fuses are damaged check the electrical insulation on the electrical apparatus Fuses are damaged In ON position check the presence of the light if no Tocker switen 13 damaged light is detected replace with a spare switch Equipment will not turn on Internal wiring connection are not Open the equipment and verify internal electrical wiring completed see functional layout Charge the battery for 12 hours and check see indicators paragraph With a multimeter check the voltage between the positive and negative pole if the voltage value is not around 10V dc replace the battery see battery paragraph Battery low or battery fault l Possible Cause li Solution l Vacuum regulator do not work properly Internal tubing are not properly connected Internal tubing are choked Turn the manifold SP 21 Open the equipment and verify internal tubing connection Open the equipment and verify internal tubing bends Open the equipment disconnect the tubing and check the pump Situation Possible Caus