1. 5 Use 1 Connect feeder of CH and HSW pump a yellow green conductor to earth terminal b blue conductor to N terminal c brown conductor to L terminal 2 After connecting the blower pumps and after installing all sensors turn the controller on After performing above actions the controller ensures a maintaining constant temperature of CH boiler set up by user b automatic start of pumps and blower c automatic shutdown of the blower and pumps after fuel use up d continuous readout of temperatures EIECIRONIS SP 24 Manual LOGIC 9 6 Error messages Error 0 Device failure Error 1 EEPROM memory failure Error 2 CH temperature sensor failure Error 3 HSW temperature sensor failure Error 5 Floor pump sensor failure Error 6 Too high CH temperature Error 8 Too high HSW temperature Error 9 No fuel T Fuse replacement To replace the fuse disconnect the feeder from the socket 8 1 2 Installation recommendations Controller installation should be entrusted to authorized person Controller should be placed in location disabling it becoming heated above 40 C Perform installation in accordance with par 5 Use Device should be installed and operated in accordance with rules of operating electrical devices Controller must not be exposed to water or to conditions causing steam condensation i e rapid changes of ambient temperature In cases of con
2. iClECIKONKCS MICROPROCESSOR TEMPERATURE CONTROLLER SERVICE MANUAL WARRANTY CARD 2 SP 24 Manual LOGIC 1 Front panel description Controller view with marked functions Turning on hold ENTER button for 2 sec LCD display Indicator lights Device control buttons Airflow start up indicator Central heating pump start up indicator Hot service water pump start up indicator Floor pump start up indicator Loader start up indicator A fuse EIECIRONIS SP 24 Manual LOGIC 3 2 Application Controller is equipped with innovative intelligent Logic control system This system consists in automatic adjustment of boiler power to current operating conditions All regulation process is based on measurement of central heating temperature Due to innovative solution enabling optimal fuel combustion in the boiler it has the effect of reduction of harmful oxides emission into the atmosphere With proper oxides aftercombustion and no overshoots boiler equipped with our device can use up to 30 less fuel than standard solutions 3 Controller operation To start up the controller hold ENTER button After controller start up main page with following information is displayed on LCD Central heating CH temperatures current and Oye Si Cr set up HSV 22 C Z 45C Hot service water HSW temperatures current and set From the main page you ha
3. causes saving set up parameter in FUEL TYPE menu i lECIRONKCS 8 SP 24 Manual LOGIC MAXIMUM POWER TEST function consists in MAX PONER TEST adjusting the amount of loaded fuel in relation to 215 4 3 maximum amount of loaded air forced to the furnace by the blower During test your task is to set up maximum fuel dose in a way that fuel feeding should be directly proportional to combustion At the moment of carrying out the test boiler operates with maximum power During test the controller monitors CH temperature In case of exceeding 80 C controller terminates the test and enters into operation mode Confirmation of parameter causes saving set up parameter in FUEL TYPE menu CAUTION Electronics company does not bear any responsibilities for improper 4 Technical data CH temperature adjustment range 35 C 80 C HSW temperature adjustment range 35 C 65 C HSW floor adjustment range 20 C 55 C Automatic blower adjustment Operation in ambient temperature 0 C 40 C Automatic saving of settings during supply voltage decay Relative air humidity 95 1 insulation class 7 A fuse Controller has got function preventing from premature freezing of installation in case oftemperature decrease below 6 C circulation pump starts up automatically Controller is equipped with secondary protection emergency thermostat which protects the boiler against overheating
4. sec which due to temporary loss of efficiency has to be regulated BLOWER START UP When you notice that the blower does not work 1 0 SEK correctly during start it cannot start you should increase start up time ROOM REGULATOR room regulator may be ROOM REGULATOR connected to the controller It controls CH circulation pump Two core cable is led out from room regulator that should be connected to jack REGULRTO input No external power sources should be connected to the device during installation of room regulator When function is turned on an arrow should appear on the display upper right area If room regulator is not connected to the device this function should not be turned on co EZ FLUE GAS TEMPERATURE option there is MAX FLUE GAS TEMP possibility of chimney sensor installation 250 C Function allows to set up maximum threshold of flue gas temperature WORM TEMPERATURE this unction protects WORM TEMPERATURE against fuel ignition in boiler basket When temperature of the worm increases above set up temperature loader will start giving the fuel for E MS 10 min in order not to allow the fuel to ignite in RURE boiler basket ELKINONKS N SP 24 Manual LOGIC ADJUSTING THE AMOUNT OF LOADED FUEL They are two tests test of minimum and maximum power Proper setting of those two parameters guarantees efficient operation of the boiler Test should be carried out for each fuel
5. arranty card on the day of giving out the equipment Warranty card which is not filled in or having any corrections or cross outs precludes exercising warranty rights 75 Information on utilization of electric and electronic devices This symbol placed on products or documentation attached to them informs that unserviceable electric or electronic devices must not be thrown away together with garbage Proper behaviour in case of necessity of utilization reuse or components recovery consists in handing over the device to specialized collection point where you shall not be charged Proper utilization of the device enables preservation of valuable resources and avoidance of negative effect to the health and environment Detailed information about the nearest collection point may be obtained from your local authorities EIECIRONIS LOOIC 11 EIECIRONIS Producent Zak ad Elektroniczny Electronics Tadeusz Wilgocki ul Moczyd o 10a 30 698 Krak w tel 012 650 47 90 fax 012 650 47 91 e mail biuroQelectronics net pl
6. hen service water temperature decreases to 48 C This function works in HSW priority and summer mode CH HSW PRIORITY 5 PRORITY HSW PRIORITY HSW pump starts up and works until achieves set up temperature When services water reaches set up temperature HSW pump turns off and CH pump turns on HSU PRORITS CH PRIORITY in this mode pumps start working PRORITY when boiler temperature reaches temperature set up in pump start up function CH pump works permanently and HSW pump turns on after reaching desired temperature In this mode HSW temperature cannot be higher than CH temperature FUEL TYPE function allows to select previously adjusted fuel i e different calorific value of fuel EL Controller is possible to adjust and save four various fuel configurations More information on adjusting loaded fuel in further part of the manual cz EIECIRONIS UT SP 24 Manual LOGIC FLOOR HEATING Controller is equipped with input supplying the floor pump and temperature sensor which is installed on recycle of floor installation Floor FLODR TEMP installation also requires installation of tee valve z 3506 on boiler output in order to limit temperature of installation supply This function ensures readout and maintaining constant temperature of floor installation Turning off the function is performed the same as for other pumps you should go below minimum temperature and t
7. hen two horizontal lines shall appear on the screen confirmation with ENTER button To start the function again set desired temperature and press the ENTER button FLUUR HEATING MANUFACTURER SETTINGS controller is MANUF SETTINGS equipped with programmed settings you may return to them at any time However you should remember that all personal settings will be lost ji NUF SETTINGS END OF WORK turns the controller off To turn END OF WORK it on again press and hold ENTER button END OF WORK 5 Controller has got hidden installation menu to get there press and hold a and w buttons for 3 seconds Changes of parameters in that menu should be made by qualified person Unauthorized changes of those parameters may cause controller misoperation INSTALLATION MENU TURN OFF TIME function is to set time whichis Mien GFF TINE measured when CH temperature does not increase and maintains 5 C below set temperature TURN OFF TIME 60 MIN EIECIRONIS 6 SP 24 Manual LOGIC MAINTENANCE PAUSE function enables setting maintenance PAUS up break time between blower and loader start u in maintenance mode en Ee PRUS 15 MAINTENANCE OPERATION function allows MAINTENANCE YORK setting up time of blower and loader operation in maintenance mode MAINTENANCE UORK 30 SEK BLOWER START UP this function consists in BLOWER START UP setting 100 power of blower with time parameter 1sec 15
8. troller misoperation first check a the fuse b connections stability and technical condition of cooperating devices that means the blower pumps Set the controller to manufacturer settings 6 Boiler should have check valves installed in cycles of CH and HSW pumps 7 Floor installation requires installation of tee valve on boiler output in order CAUTION Perform connecting blower and circulation pumps motors only after disconnection of the controller from 230V supply network 9 Electric parameters 1 Supply voltage 230 V 50 Hz 2 Power consumption no ratings 2 W 3 Output ratings blower 100 W loader 250 W pumps CH 100 W HSW 100 W floor 100 W ELKIONKCS 10 Warranty card LOGIC 10 Warranty card 1 Manufacturer guarantees good quality of equipment guarantee and post guarantee services 2 Manufacturer grants the guarantee of failure free controller operation for the period of 24 month from purchase date 3 Failures and damages revealed during warranty period shall be eliminated immediately free of charge within not longer than 14 days from the day of delivering the device for repair at manufacturer location Shipment costs are incurred by the customer When making a complaint failure description should be attached Warranty does not include damages arose due to improper operation by the user or modifications and repairs performed not by service centre 7 Seller is obliged to fill in the w
9. ve the access to several functions pressing 4 enters into central heating temperature adjusting mode you set up desired temperature with w and a When temperature decreases below 35 C and ENTER button is pressed central heating pump turns off Controller enters SUMMER MODE with only hot service water function However if w is pressed as first you enter into setting up hot service water temperature By pressing 4 and w you set up desired temperature When temperature decreases below 35 C and ENTER button is pressed hot service water pump turns off Caution If installation is not equipped wit hot service water pump you should turn off water heating function Pressing ENTER button confirms selected parameter and pressing EXIT button exits without saving previously made changes CH Temperature m L Blower power BLOWER POW 30 5 4 SP 24 Manual LOGIC FUNCTIONS MANUAL OPERATION function is to fire up the MANUAL OPERATION boiler it enables independent start up of controller BLOWER Pressing ENTER button turns on one of the outputs With 4 and w you change output to be turned on or off Pressing EXIT returns to set up menu HSW hysteresis that function is to set up service water hysteresis it consists in delaying HSW pump start up by set up number of degrees i e hystheresis 2 set up temperature 50 C pump enia 515 KE HOU inher 5 shall start up w
10. you intend to use fuel change requires carrying out new test Change of minimum power of the blower will cause change of minimum power for each fuel 1 2 3 4 Improper adjustment of the fuel may result in retort loader damage MIN BLOWER POWER function is to set up AIN BLOYER PON minimum fan power Fan should be set up to work at minimum power However you should remember that fans lose their factory parameters i BLOWER POU as a result of use and soil In that situation you a should increase minimal airflow power CAUTION change of this parameter requires new adjustment of amount of loaded fuel test of minimum power for each fuel type 1 2 3 4 FUEL 1 Adjustment of amount of loaded fuel F MAX BLOWER POWER this function is to limit MAX BLOWER POUN maximum airflow power Maximum power should 99 be limited when used fuel pellet oat is too light and is blown around in combustion chamber due to huge fan power FUEL LOAD this function is for quick correction FUEL LOAD of amount of loaded fuel for minimum an 4 4 356 maximum power MINIMUM POWER TEST function consists in MIN POVER TEST adjusting the amount of loaded fuel in relation to 2 5 minimum amount of loaded air forced to the furnace by the blower During test your task is to set up fuel dose in a way that fuel feeding shoul be directly proportional to combustion Recommended time of minimum power test is 4 to 5 hrs Confirmation of parameter