Home
Mixed Signal Oscilloscopes
Contents
1. Prey ce i White edges indicate additional information is available by acquiring at a higher sample rate 144 9 599 56 MHz The multiple transition detection hardware of the MSO2000B Series will show you a white edge on the display when the system detects multiple transitions This acts as a visual reminder that increasing the sample rate on the next acquisition will reveal higher frequency information than your previous settings could acquire The MSO2000B Series simplifies channel setup by allowing you to group digital waveforms and enter waveform labels by using a USB keyboard By simply placing digital waveforms next to each other they form a group Once a group is formed you can position all the channels contained in that group collectively This greatly reduces the normal setup time associated with positioning channels individually P6316 MSO probe This unique probe design offers two eight channel pods simplifying the process of connecting to the device under test When connecting to square pins the P6316 can connect directly to 8x2 square pin headers spaced on tenth inch centers When more attachment flexibility is required you can use the included flying lead sets and grabbers to clip onto surface mount devices or test points The P6316 offers outstanding electrical characteristics applying only 8 pF of capacitive loading with 101 kQ input impedance The P6316 MSO probe offers two eight chann
2. 1 O 0rns Fal EET He Output of DAC Signal Notice how FilterVu clearly shows the noise free steps of the DAC in the foreground trace yellow which has removed all frequencies above 5 5 kHz FilterVu also captures and displays high frequency glitches up to the full bandwidth of the oscilloscope in the background trace orange Serial triggering analysis optional On a serial bus a single signal often includes address control data and clock information This can make isolating events of interest difficult The MSO DPO2000B Series offers a robust set of tools for debugging serial buses with automatic trigger decode and search for I2C SPI CAN LIN and RS 232 422 485 UART Serial triggering Trigger on packet content such as start of packet specific addresses specific data content unique identifiers etc on popular serial interfaces such as IC SPI CAN LIN and RS 232 422 485 UART Addr A 50 Data 14 Data 16 jas 00c0usfaaddess Triggering on a specific data packet going across an 2 C bus The yellow waveform is clock and the blue waveform is data A bus waveform provides decoded packet content including Start Address Read Write Data and Stop Bus display Provides a higher level combined view of the individual signals clock data chip enable etc that make up your bus making it easy to identify where packets begin and end and identifying subpacket components such as address data identifier
3. 14 oz 3 6 kg Five year warranty Connectivity USB 2 0 host port on the front panel for quick and easy data storage USB 2 0 device port on rear panel for easy connection to a PC or direct printing to a PictBridge compatible printer Optional 10 100 Ethernet port for network connection and video out port to export the oscilloscope display to a monitor or projector Optional serial triggering and analysis Automated serial triggering decode and search options for IC SPI CAN LIN and RS 232 422 485 UART Feature rich tools for debugging mixed signal designs Simplify and speed up debugging your complex design with feature rich tools including Wave Inspector controls for rapid waveform navigation and automated serial and parallel bus analysis Comprehensive features speed every stage of debug The MSO DPO2000B Series offers a robust set of features to speed every Stage of debugging your design from quickly discovering an anomaly and capturing it to searching your waveform record for the event and analyzing its characteristics and your device s behavior Discover To debug a design problem first you must know it exists Every design engineer spends time looking for problems in their design a time consuming and frustrating task without the right debug tools The MSO DPO2000B Series offers complete visualization of signals providing fast insight into the real operation of your device A waveform capture rat
4. 500 MS s 2 ns resolution Maximum record length main all 1 M points channels Minimum detectible pulse width ns Channel to channel skew 2 ns typical www tektronix com 9 Datasheet Trigger system Trigger modes Trigger coupling Trigger holdoff range Trigger sensitivity typical Trigger level ranges Any input channel Aux Input external trigger Trigger types Edge Pulse Width Runt Logic Setup and Hold Rise Fall Time Video I2C optional SPI optional RS 232 422 485 UART optional CAN optional LIN optional Parallel available on MSO models only 10 www tektronix com Auto Normal and Single DC HF reject attenuates gt 85 kHz LF reject attenuates lt 65 kHz noise reject reduces sensitivity 20 ns to 8 s Trigger source Sensitivity Internal DC coupled 0 4 div from DC to 50 MHz 0 6 div gt 50 MHz to 100 MHz 0 8 div gt 100 MHz to 200 MHz External aux input 200 mV from DC to 100 MHz 1X attenuation 4 92 divisions from center of screen 6 25 V 1X attenuation 12 5 V 10X attenuation Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC HF reject LF reject and noise reject Trigger on width of positive or negative pulses that are gt lt or inside outside a specified period of time Trigger on a pulse that crosses one threshold but fails to cross a second threshold before cross
5. DB 15 female connector connect to show the oscilloscope display on an external monitor or projector requires DPO2CONN Auxiliary input Front panel BNC connector Input Impedance 1 MQ 2 Max input 300 Vays CAT II with peaks lt 450 V Probe compensator output voltage Front panel pins and frequency Amplitude 5V Frequency 1 kHz Kensington style lock Rear panel security slot connects to standard Kensington style lock Power source Power source voltage 100 to 240 V 10 Power source frequency 45 to 65 Hz 90 to 264 V 360 to 440 Hz 100 to 132 V Power consumption 80 W maximum Optional TekVPI external power supply Output voltage 12V Output current 5A Power consumption 50 W Physical characteristics Dimensions mm in Height 180 7 1 Width 377 14 9 Depth 134 9a Weight kg Ib Net 3 6 7 9 Shipping 6 2 13 7 Rackmount configuration 4U Cooling clearance 2 in 50 mm required on left side and rear of instrument 2 Required when total oscilloscope probe power usage exceeds 20 W 12 www tektronix com MSO DPO2000B Series Mixed Signal Oscilloscope EMC environment and safety Temperature Operating 0 C to 50 C 32 F to 122 F Nonoperating 40 C to 71 C 40 F to 160 F Humidity Operating High 30 C to 50 C 5 to 60 relative humidity Low 0 C to 30 C 5 to 95 relative humidity Nonoperating High 30 C to 55 C 5 to 60 relative humidity L
6. and packet decode tables with time stamp information Embedded Serial Triggering and Analysis Module Enables triggering on packet level information on I C and SPI buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Only two wire SPI support is available on two channel models Power cord and plug options Please specify power plug version when ordering Opt A0 Opt A1 Opt A2 Opt A3 Opt A5 Opt A6 Opt A10 Opt A11 Opt A12 Opt A99 Language options 4 Opt LO Opt L1 Opt L2 Opt L3 Opt L4 Opt L5 Opt L6 Opt L7 Opt L8 Opt L9 North America power plug 115 V 60 Hz Universal Euro power plug 220 V 50 Hz United Kingdom power plug 240 V 50 Hz Australia power plug 240 V 50 Hz Switzerland power plug 220 V 50 Hz Japan power plug 100 V 110 120 V 60 Hz China power plug 50 Hz India power plug 50 Hz Brazil power plug 60 Hz No power cord English manual French manual Italian manual German manual Spanish manual Japanese manual Portuguese manual Simplified Chinese manual Traditional Chinese manual Korean manual 3 User manuals PDF in 11 languages are available on the CD and for download from http www tektronix com manuals There are no printed user manuals 4 The English option includes a front panel label on the instrument The other language options includ
7. two channels at equal vertical scale MS02002B DPO2002B MSO2004B DPO2004B MS0O2012B DPO2012B MSO2014B DPO2014B MS02022B DPO2022B MSO2024B DPO2024B 2100 1 at lt 70 MHz 2100 1 at 100 MHz 100 1 at 200 MHz Volts div setting Offset range 1 MQ input 2 mV div to 200 mV div 1V gt 200 mV div to 5 V div 25V 1 Bandwidth is 20 MHz at 2 mV div all models 8 www tektronix com MSO DPO2000B Series Mixed Signal Oscilloscope Vertical system digital channels Input channels 16 digital D15 to DO Thresholds Threshold per set of 8 channels Threshold selections TTL CMOS ECL PECL User defined User defined threshold range 20V Threshold accuracy 100 mV 3 of threshold setting Maximum input voltage 40 V Input dynamic range 80 Vpk pk threshold setting dependent Minimum voltage swing 900 mV Input resistance 101 KQ Probe loading 8 pF Vertical resolution 1 bit Horizontal system analog channels Maximum duration of time 1 ms captured at highest sample rate all channels Time base range 200 MHz models 2ns to 100s 70 100 MHz models 4ns to 100s Time base delay time range 10 divisions to 5000 s Channel to channel deskew range 100 ns Time base accuracy 25 ppm over any 21 ms interval Horizontal system digital channels Maximum sample rate main When using any of channels D7 D0 When using any of channels D8 D15 1 GS s 1 ns resolution
8. 0 MHz 1 GS s 1M record length 2 16 channel mixed signal oscilloscope MSO2024B 200 MHz 1 GS s 1 M record length 4 16 channel mixed signal oscilloscope Standard accessories Probes TPP0200 200 MHz 10x passive probe one per analog channel for 100 and 200 MHz models TPP0100 100 MHz 10x passive probe one per analog channel for 70 MHz models P6316 MSO models only 16 channel logic probe and accessory kit one per instrument Accessories 063 4472 xx Documentation CD 016 2008 xx Accessory pouch 071 3078 xx Installation and safety manual Power cord OpenChoice Desktop software Calibration certificate documenting traceability to National Metrology Institute s and IS09001 quality system registration Warranty Five year warranty covering all parts and labor excluding probes 14 www tektronix com Application modules DPO2AUTO DPO2COMP DPO2EMBD Instrument options MSO DPO2000B Series Mixed Signal Oscilloscope Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN bus and LIN bus as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Computer Serial Triggering and Analysis Module Enables triggering on packet level information on RS 232 422 485 UART buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools
9. CRC etc www tektronix com 5 Datasheet Bus decoding Tired of having to visually inspect the waveform to count clocks determine if each bit is a 1 or a 0 combine bits into bytes and determine the hex value Let the oscilloscope do it for you Once you ve set up a bus the MSO DPO2000B Series will decode each packet on the bus and display the value in hex binary decimal LIN only or ASCII RS 232 422 485 UART only in the bus waveform Event table In addition to seeing decoded packet data on the bus waveform itself you can view all captured packets in a tabular view much like you would see in a software listing Packets are time stamped and listed consecutively with columns for each component Address Data etc Time Identifier DLE Data CAC Missing Ack W122 3344 5566 rro Abe FE 3823ms 1597EEB2 AEAFFFFTOZrQORBB 219000 saison geese oa 37 sms 18181815 F1F2 F3F4 FSFE FT oF 3B selects an event Event table showing decoded Identifier DLC DATA and CRC for every CAN packet in a long acquisition Search Serial triggering is very useful for isolating the event of interest but once you ve captured it and need to analyze the surrounding data what do you do In the past users had to manually scroll through the waveform counting and converting bits and looking for what caused the event With the MSO DPOQ2000B Series you can have the oscilloscope automatically search through the acquired data for u
10. Tektronix Mixed Signal Oscilloscopes MSO2000B Series DPO2000B Series Datasheet sOOOOLOLOO oS Je gt a fo Offering up to 200 MHz bandwidth and 1 GS s sample rate the MSO DPO2000B Mixed Signal Oscilloscope Series from Tektronix delivers advanced debug features at an entry level price Quickly find and diagnose problems in complex designs with up to 20 channels for analyzing analog and digital signals With a deep record length of 1 Mpoints standard on all channels the MSO DPO20008B lets you capture long windows of signal activity while maintaining fine timing resolution Key performance specifications 200 100 70 MHz bandwidth models 2 and 4 analog channel models 16 digital channels MSO series 1 GS s sample rate on all channels 1 megapoint record length on all channels 5 000 wfm s maximum waveform capture rate Suite of advanced triggers Key features Wave Inspector controls provide easy navigation and automated search of waveform data FilterVu variable low pass filter allows for removal of unwanted signal noise while still capturing high frequency events 29 automated measurements and FFT analysis for simplified waveform analysis TekVPI probe interface supports active differential and current probes for automatic scaling and units 7 in 180 mm wide screen TFT LCD color display Small footprint and lightweight only 5 3 in 134 mm deep and 7 lb
11. croll faster and changing direction is as simple as turning the control the other way M10 0us Zoom Factor 1 100 O08 Noise Filter Off Z 100ns Wave Inspector controls provide unprecedented efficiency in viewing navigating and analyzing waveform data Zip through your 1 Mpoint record by turning the outer pan control 1 Get from the beginning to end in seconds See something of interest and want to see more details Just turn the inner zoom control 2 MSO DPO2000B Series Mixed Signal Oscilloscope User marks Press the Set Mark front panel button to place one or more marks on the waveform Navigating between marks is as simple as pressing the Previous lt and Next buttons on the front panel Search marks The Search button allows you to automatically search through your long acquisition looking for user defined events All occurrences of the event are highlighted with search marks and are easily navigated to using the front panel Previous lt and Next buttons Search types include edge pulse width glitch runt logic setup and hold rise fall time parallel bus and I2C SPI CAN LIN and RS 232 422 485 UART packet content M10 0ms Zoom Factor S00 4 Noise Filter 01 Can Identifier Standard Hee tsa Ea or hey digit sets jts value 2 eee L I Lt ULI OU tL U Lo IL U JAH Dd H DGI H DEC HOC CRC Prd ess am 1564 ZESA tifie a Bus PRECA d 4 Data ie Sh ai Search step 1 You defi
12. dback system lets you move from one end of your record to the other in just seconds You can mark any location you may want to reference later for further investigation and automatically search the record using criteria that you define Wave Inspector will instantly search your entire record including analog digital and serial bus data Along the way it will automatically mark every occurrence of your defined event so you can quickly move between events To Previu air Py M10 0ms Zoom Factor 2907 Noise Filter Off Search events found 115 Search 2C decode showing results from a Wave Inspector search for Address value 50 Wave Inspector controls provide unprecedented efficiency in viewing and navigating waveform data Analyze Verifying that your prototype s performance matches simulations and meets the project s design goals requires analyzing its behavior Tasks can range from simple checks of rise times and pulse widths to sophisticated power loss analysis and investigation of noise sources The MSO DPO2000B Series offers a comprehensive set of integrated analysis tools including waveform and screen based cursors 29 automated measurements and FFT analysis Specialized application support for serial bus analysis is also available J Prev ff nis Filter OFF fons 000000 133337MH Analyze FFT analysis of a pulsed signal A comprehensive set of integrated analysis tools speeds verifica
13. e a front panel overlay www tektronix com 19 Datasheet Opt L10 Russian manual Opt L99 No manual Language options include translated front panel overlay for the selected language s Service options Opt D1 Calibration Data Report Recommended accessories Probes Tektronix offers over 100 different probes to meet your application needs For a comprehensive listing of available probes please visit www tektronix com probes ADA400A 100X 10X 1X 0 1X high gain differential amplifier P5100A 2 5 kV 500 MHz 100X high voltage passive probe TAP1500 1 5 GHz TekVPI active voltage probe TCP0020 50 MHz TekVPI 20 Ampere AC DC current probe TCP0030 120 MHz TekVPI 30 Ampere AC DC current probe TCP0150 20 MHz TekVPI 150 Ampere AC DC current probe TCP2020 50 MHz TekVPI 20 Ampere AC DC current probe TCPA300 400 Current measurement systems amplifier TCP305 DC to 50 MHz 50 Ampere current probe for use with TCPA300 TCP404XL DC to 2 MHz 500 Ampere current probe for use with TCPA400 TDP0500 500 MHz TekVPI differential voltage probe with 42 V differential input voltage 8 THDP0200 1 5 kV 200 MHz high voltage differential probe 8 THDP0100 6 kV 100 MHz high voltage differential probe TMDP0200 750 V 200 MHz high voltage differential probe 5 Requires TPA BNC adapter 6 Requires TekVPI external power adapter 119 7465 00 one per oscilloscope 7 Requires 50 Q feed through termination betwe
14. e of 5 000 waveforms per second enables you to see glitches and other infrequent transients quickly revealing the true nature of device faults A digital phosphor display with intensity grading shows the history of a signal s activity by intensifying areas of the signal that occur more frequently providing a visual display of just how often anomalies occur testforce www tektronix com 1 Datasheet Tek Sto p nein i i fat ons gagap 88 8855 Discover A waveform capture rate of 5 000 wfm s maximizes the probability of capturing elusive glitches and other infrequent events G m 18 4450H Capture Discovering a device fault is only the first step Next you must capture the event of interest to identify root cause The MSO DPO2000B Series provides a complete set of triggers including runt logic pulse width glitch setup hold violation serial packet and parallel data to help quickly find your event With up to a 1 Mpoint record length you can capture many events of interest even thousands of serial packets in a single acquisition for further analysis while maintaining high resolution to zoom in on fine signal details From triggering on specific packet content to automatic decode in multiple data formats the MSO DPO2000B Series provides integrated support for a broad range of serial buses IC SPI CAN LIN and RS 232 422 485 UART The ability to decode up to two serial and or para
15. el pods to simplify connecting to your device FilterVu variable low pass filter Tired of being limited to a 20 MHz bandwidth filter in your oscilloscope Simply turn on FilterVu and adjust the variable low pass noise filter Unlike other variable low pass filters FilterVu filters out the unwanted noise from your signal while still capturing glitches and other signal details up to the full bandwidth of the oscilloscope It does this by showing two waveforms a waveform that can be filtered foreground waveform and a glitch capture waveform background waveform The filtered waveform uses a variable low pass filter to block out noise yielding a cleaner waveform to more precisely locate signal edges and amplitude levels The result is improved confidence in you cursor measurements and cleaner documentation of important signal attributes When the noise filter is adjusted to the lowest available noise cutoff frequency no more than 1 of high frequency content that could cause the oscilloscope to alias will pass through the filter The glitch capture waveform shows signal details up to the full bandwidth of the oscilloscope The oscilloscope captures pulses as narrow as 5 ns using peak detect min max sampling protecting you from missing unexpected glitches or other high frequency events FilterVu is ideal for repetitive nonrepetitive and single shot events MSO DPO2000B Series Mixed Signal Oscilloscope S SOkH Moise Filteryu
16. en the oscilloscope input and the BNC cable 8 Probes terminate into 50 Q but oscilloscope will automatically adjust to account for 1 MQ input 16 www tektronix com MSO DPO2000B Series Mixed Signal Oscilloscope Accessories DPO2CONN Adds Ethernet 10 100Base T and video out port 077 0737 xx Service manual English only PDF only downloadable from www tektronix com manuals TPA BNC TekVPI to TekProbe BNC adapter TEK DPG TekVPI Deskew pulse generator signal source 067 1686 xx Power measurement deskew and calibration fixture 196 3508 xx Digital Probe Leadset 8 channels 119 7465 xx TekVPI external power supply power cord not included TEK USB 488 GPIB to USB adapter ACD2000 Soft transit case 200 5045 xx Front protective cover HCTEK4321 Hard transit case requires ACD2000 RMD2000 Rackmount kit Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar GPIB Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats IEEE 488 www tektronix com 17 Datasheet testforc For more information contact us at sales testforce com or call us toll free at 1 888 880 6804 www testforce com ASEAN Australasia 65 6356 3900 Austria 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 00800 2255 4835 Brazil 55 11 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics 41 52 675 3777 Central Europe am
17. ice marks trademarks or registered trademarks of their respective companies e i 19 Mar 2014 3GW 28413 2 www tektronix com Tektronix Pi
18. ing the first again Trigger when any logical pattern of channels goes false or stays true for specified period of time Any input can be used as a clock to look for the pattern on a clock edge Pattern AND OR NAND NOR specified for all input channels defined as High Low or Don t Care Trigger on violations of both setup time and hold time between clock and data present on any of the analog and digital input channels Trigger on pulse edge rates that are faster or slower than specified Slope may be positive negative or either Trigger on all lines odd even or all fields on NTSC PAL and SECAM video signals Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data or Address and Data on IC buses up to 3 4 Mb S Trigger on SS MOSI MISO or MOSI and MISO on SPI buses up to 10 0 Mb s Trigger on Tx Start Bit Rx Start Bit Tx End of Packet Rx End of Packet Tx Data Rx Data Tx Parity Error and Rx Parity Error up to 10 Mb s Trigger on Start of Frame Frame Type data remote error overload Identifier standard or extended Data Identifier and Data End of Frame Missing ACK or Bit Stuffing Error on CAN signals up to 1 Mb s Data can be further specified to trigger on lt lt gt 2 or a specific data value User adjustable sample point is set to 50 by default Trigger on Sync Identifier Data Identifier and Data Wakeup Frame Sleep Frame Errors such as Sync Parity or Checksum Er
19. llel buses simultaneously means you gain insight into system level problems quickly To further help troubleshoot system level interactions in complex embedded systems the MSO2000B Series offers 16 digital channels in addition to its analog channels Since the digital channels are fully integrated into the oscilloscope you can trigger across all input channels automatically time correlating all analog digital and serial signals Pfs prenu Trigger On lid Ts Start Bit Ax Start Bit AT He tk tt tt ta tn ip hn anana CA Ti End of Packet Aix End of Packet meer 4 00ms ADT Start Bit Made Mormal amp Holdott Type Source Bus Trigger On Bus WEDCRS 2525 Tx Start Bit Capture Triggering on a specific transmit data packet going across an RS 232 bus A complete set of triggers including triggers for specific serial packet content ensures you quickly capture your event of interest 2 www tektronix com Search Finding your event of interest in a long waveform record can be time consuming without the right search tools With today s record lengths pushing to a million data points locating your event can mean scrolling through thousands of screens of signal activity The MSO DPO2000B Series offers the industry s most comprehensive search and waveform navigation with its innovative Wave Inspector controls These controls speed panning and zooming through your record A unique force fee
20. ne what you would like to find Search events found 10 M 10 0ms Zoom Factor S00 r Moise Filter Off 514 4uU042H DGS H OGC H OGC CAC f744 20 005 545836kHz 74555 Search events found 10 Search step 2 Wave Inspector automatically searches through the record and marks each event with a hollow white triangle You can then use the Previous and Next buttons to jump from one event to the next www tektronix com 3 Datasheet Digital phosphor technology The MSO DPO2000B Series digital phosphor technology provides you with fast insight into the real operation of your device Its waveform capture rate of 5 000 wfm s gives you a high probability of quickly seeing the infrequent problems common in digital systems runt pulses glitches timing issues and more Waveforms are superimposed with one another and waveform points that occur more frequently are intensified This quickly highlights the events that over time occur more often or in the case of infrequent anomalies occur less often With the MSO DPO2000B Series you can choose infinite persistence or variable persistence determining how long the previous waveform acquisitions stay on screen This allows you to determine how often an anomaly is occurring Tek Co sSNisee Filter OF ae 10 45 54 Soon 4 oons a Mn Digital phosphor technology enables a 5 000 wfm s waveform capture rate and real time intensity grading on the MSO DPO2000B Series Mi
21. onitor or projector Compact form factor A compact portable form factor allows the MSO DPO2000B Series to be easily moved between labs and with a depth of just 5 3 inches 134 mm it saves you valuable space on your test bench MSO DPO2000B Series Mixed Signal Oscilloscope Extended analysis Acquiring data and measurements from the MSO DPQ2000B Series is as simple as connecting a USB cable from the oscilloscope to your PC Key software applications OpenChoice Desktop and Microsoft Excel and Word toolbars are included standard with each oscilloscope to enable fast and easy direct communication with your Windows PC For simple tasks the included OpenChoice Desktop enables fast and easy communication between the oscilloscope and your PC through USB GPIB or LAN for transferring settings waveforms and screen images MSO2024 OpenChoice Desktop ae a sens EEY A Preferences Select Instrument a MS0O2024 Noise Filter Off Get Screen 5 fz J UE The MSO DPO2000B Series compact form factor frees up valuable space on your bench m pen or desktop TekVPI probe interface aS CT Pe a Test Station 1 Tek MSO2024 DAC The TekVPI probe interface sets the standard for ease of use in probing Copy to Clipboard TekVPI probes feature status indicators and controls as well as a probe Modify Note Tektronix menu button right on the comp box itself This button brings up a probe menu on the oscilloscope display
22. ow 0 C to 30 C 5 to 95 relative humidity Altitude Operating 3 000 meters 9 843 feet Nonoperating 12 000 meters 39 370 feet Random vibration Operating 0 31 Grys from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total Nonoperating 2 46 Grys from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total Regulatory Electromagnetic compatibility EC Council Directive 2004 108 EC Safety UL61010 1 2004 CAN CSA C22 2 No 61010 1 2004 EN61010 1 2001 complies with the Low Voltage Directive 2004 108 EC for Product Safety www tektronix com 13 Datasheet Ordering information MSO DPO2000B family DPO2002B 70 MHz 1 GS s 1 M record length 2 channel digital phosphor oscilloscope DPO2004B 70 MHz 1 GS s 1 M record length 4 channel digital phosphor oscilloscope DPO2012B 100 MHz 1 GS s 1 M record length 2 channel digital phosphor oscilloscope DPO2014B 100 MHz 1 GS s 1 M record length 4 channel digital phosphor oscilloscope DPO2022B 200 MHz 1GS s 1 M record length 2 channel digital phosphor oscilloscope DPO2024B 200 MHz 1 GS s 1 M record length 4 channel digital phosphor oscilloscope MSO2002B 70 MHz 1 GS s 1 M record length 2 16 channel mixed signal oscilloscope MSO2004B 70 MHz 1 GS s 1M record length 4 16 channel mixed signal oscilloscope MSO2012B 100 MHz 1 GS s 1M record length 2 16 channel mixed signal oscilloscope MSO2014B 100 MHz 1GS s 1M record length 4 16 channel mixed signal oscilloscope MSO2022B 20
23. p Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 00800 2255 4835 Germany 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835 Japan 81 3 6714 3010 Luxembourg 41 52 675 3777 Mexico Central South America amp Caribbean 52 55 56 04 50 90 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 00800 2255 4835 Norway 800 16098 People s Republic of China 400 820 5835 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia amp CIS 7 495 6647564 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2255 4835 Switzerland 00800 2255 4835 Taiwan 886 2 2722 9622 United Kingdom amp Ireland 00800 2255 4835 USA 1 800 833 9200 European toll free number If not accessible call 41 52 675 3777 Updated 10 April 2013 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and ras price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the serv
24. rors Trigger on a parallel bus data value Acquisition system Acquisition Modes Sample Peak Detect Averaging Roll Waveform measurements Cursors Automatic measurements Gating Waveform math Arithmetic FFT Software OpenChoice Desktop IVI driver e Scope Web based remote control Display system Display type Display resolution Waveform styles Graticules Format Maximum waveform capture rate MSO DPO2000B Series Mixed Signal Oscilloscope Acquire sampled values Captures glitches as narrow as 3 5 ns at all sweep speeds From 2 to 512 waveforms included in average Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms div Waveform and Screen 29 of which up to four can be displayed on screen at any one time Measurements include Period Frequency Delay Rise Time Fall Time Positive Duty Cycle Negative Duty Cycle Positive Pulse Width Negative Pulse Width Burst Width Phase Positive Overshoot Negative Overshoot Peak to Peak Amplitude High Low Max Min Mean Cycle Mean RMS Cycle RMS Positive Pulse Count Negative Pulse Count Rising Edge Count Falling Edge Count Area and Cycle Area Isolate the specific occurrence within an acquisition to take measurements on using either the screen or waveform cursors Add subtract and multiply waveforms Spectral magnitude Set FFT Vertical Scale to Linear RMS or dBV RMS and FFT Window to Rectang
25. ser defined criteria including serial packet content Each occurrence is highlighted by a search mark Rapid navigation between marks is as simple as pressing the Previous lt and Next buttons on the front panel 6 www tektronix com Designed to make your work easier The MSO DPO20008B is designed to make your work easier The bright widescreen display shows a long time window Dedicated front panel controls simplify operation A USB host port on the front panel allows you to easily transfer screenshots instrument settings and waveform data to a memory st o OOOO OO Bright widescreen display The MSO DPO2000B Series features a 7 inch 180 mm widescreen TFT LCD display for seeing intricate signal details Dedicated front panel controls Per channel vertical controls provide simple and intuitive operation No longer do you need to share one set of vertical controls across all four channels Connectivity A USB host port on the front panel enables easy transfer of screenshots instrument settings and waveform data to a USB thumb drive The rear panel contains a USB device port for controlling the oscilloscope remotely from a PC or for connecting a USB keyboard The USB device port can also be used to print directly to a PictBridge compatible printer An optional 10 100 Ethernet port enables easy connection to networks and an optional Video Out port allows the oscilloscope display to be exported to an external m
26. tion of your design s performance D i Wave Inspector navigation and search A 1 M point record length represents thousands of screens of information The MSO DPO2000B Series enables you to search through it all and find your event in seconds with Wave Inspector the industry s best tool for navigation and search Wave Inspector offers the following innovative controls Zoom pan A dedicated two tier front panel control provides intuitive control of both zooming and panning The inner control adjusts the zoom factor or zoom scale turning it clockwise activates zoom and goes to progressively higher zoom factors while turning it counterclockwise results in lower zoom factors and eventually turning zoom off No longer do you need to navigate through multiple menus to adjust your zoom view The outer control pans the zoom box across the waveform to quickly get to the portion of waveform you are interested in The outer control also utilizes force feedback to determine how fast to pan on the waveform The farther you turn the outer control the faster the zoom box moves Pan direction is changed by simply turning the control the other way Play pause A dedicated play pause front panel button scrolls the waveform across the display automatically while you look for anomalies or an event of interest Playback speed and direction are controlled using the intuitive pan control Once again turning the control further makes the waveform s
27. ular Hamming Hanning or Blackman Harris Enables fast and easy communication between a Windows PC and your oscilloscope using USB or LAN Transfer and save settings waveforms measurements and screen images Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft NET and MATLAB Enables control of the oscilloscope over a network connection through a standard web browser Simply enter the IP address or network name of the oscilloscope and a web page will be served to the browser 7 inch 180 mm wide format liquid crystal TFT color display 480 horizontal x 234 vertical pixels WQVGA Vectors Dots Variable Persistence Infinite Persistence Full Grid Cross Hair Frame YT and XY Up to 5 000 wfm s www tektronix com 11 Datasheet Input output ports USB 2 0 high speed host port Supports USB mass storage devices printers and keyboards One port available on rear panel and one on front panel USB 2 0 high speed device port Rear panel connector allows for communication control of oscilloscope through USBTMC or GPIB with a TEK USB 488 and direct printing to all PictBridge compatible printers LAN port Ethernet RJ 45 connector supports 10 100BASE T requires DPO2CONN Video out port
28. with all relevant settings and controls for the probe TekVPI probes can be controlled remotely through USB GPIB OpenChoice Desktop software enables seamless connection between the oscilloscope or Ethernet enabling more versatile solutions in ATE environments ane yen TekVPI probe interface simplifies connecting your probes to the oscilloscope www tektronix com 7 Datasheet Specifications All specifications apply to all models unless noted otherwise Model overview MSO2002B and MSO2004B and MSO2012B and MSO2014B and MSO2022B and MSO2024B and DPO2002B DPO2004B DPO2012B DPO2014B DPO2022B DPO2024B Analog channels 2 4 2 4 2 4 Bandwidth 70 MHz 70 MHz 100 MHz 100 MHz 200 MHz 200 MHz Rise time 5 ns 5 ns 3 5 ns 3 5 ns 2 1 ns 2 1 ns Sample rate 1 GS s 1 GS s 1 GS s 1 GS s 1 GS s 1 GS s Record length 1 M points 1 M points 1 M points 1 M points 1 M points 1 M points Digital channels MSO models add 16 digital channels to the corresponding DPO model Vertical system analog channels Hardware bandwidth limits Input coupling Input impedance Input sensitivity range Vertical resolution Maximum input voltage 1 MQ DC gain accuracy with offset set to 0 V Channel to channel isolation Offset range 20 MHz AC DC GND 1 MQ 2 11 5 pF 2 pF 2 mV div to 5 V div 8 bits 300 VRMS with peaks lt 450 V 3 for 10 mV div to 5 V div 4 for 2 mV div to 5 mV div Any
29. xed signal design and analysis MSO series The MSO2000B Series Mixed Signal Oscilloscopes provide 16 digital channels These channels are tightly integrated into the oscilloscope s user interface simplifying operation and making it possible to solve mixed signal issues easily Te Prev Oo a o e The MSO Series provides 16 integrated digital channels enabling you to view and analyze time correlated analog and digital signals 4 www tektronix com Color coded digital waveform display The MSO2000B Series has redefined the way you view digital waveforms One common problem shared by both logic analyzers and mixed signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display The MSO2000B Series has color coded digital traces displaying ones in green and zeros in blue Dio Prevyu en Threshalds LDinital Channel be i Family Value oma o ELT Te TTL 144 ant gO UU UU a 25V E o es m 25VCMOS 125V i ue Apply Preset jannus oe eure aha Thresholds Pa Height ss on mee Labels 0 Fesolution 1 00ns With the color coded digital waveform display groups are created by simply placing digital channels together on the screen allowing the digital channels to be moved as a group You can set threshold values for each pod of eight channels enabling support for up to two different logic families
Download Pdf Manuals
Related Search
Related Contents
Fujitsu LIFEBOOK NH532 Pressione. - Atele Serv Ver ficha técnica PACSystems RX3i Ethernet NIU Plus, IC695NIU001 Olfa 720-0430 User's Manual KMK/JŻ IDE User's Manual 洗浄水量の切替方法 水たまり面が低下する場合の対応方法 Sur www.inrs.fr Copyright © All rights reserved.
Failed to retrieve file