Home

TRIPLE OUTPUT POWER SUPPLY HP MODEL E3630A

image

Contents

1. 10 47 63 Hz Input OE9 100 Vac 10 47 63 Hz Input 910 One additional operating and service manual shipped with the power supply ACCESSORY The accessory listed below may be ordered from your local Hewlett Packard Sales Office either with the power supply or separately Refer to the list at the rear of the manual for address HP Part No 5063 9767 Description Rack Kit for mounting one or two 3 1 2 high supplies in a standard 19 rack The rack mount kit is needed for rack mounting of the E3630A power supply DESCRIPTION This constant voltage current limiting triple output power sup ply combines two 0 to 20V tracking outputs rated at 0 5 amps with an additional single output that is rated at 0 to 6 volts and 2 5 amps The 20V and 20V tracking outputs can also be used in series as a single 0 to 40V 0 5 amp output Connections to the supply s output and to chassis ground are made to binding posts on the front panel The supply s three outputs share a common output terminal which is isolated from chassis ground so that any one output terminal can be grounded All outputs are protected against overload and short circuit damage The 20V outputs are protected by circuits that limit the output current to 110 of its nominal maximum The over load protection circuit for the 6V output has a current fold back characteristic that reduces the output current as an overload increases until only 1 amp flows through a short cir
2. cord plug appropriate for the user s location Notify the near est HP Sales and Service Office if the appropriate power cord is not included with the supply ___ 20 6mm 3 567in 269 2 mm 10591 in A IM 3184 mm 2 534 in Figure 1 Outline Diagram OPERATING INSTRUCTIONS INTRODUCTION The following steps describe the use of the front panel con trols and indicators illustrated in Figure 2 and serve as a brief check that the supply is operational Follow this checkout pro cedure or the more detailed performance test of service infor mation section when the instrument is received and before it is connected to any load equipment A HEWLETT ESGBOA D W 25A 0 20V 0 5A STA PACKARD TRIPLE OUTPUT DC POWER SUPPLY Figure 2 Front Panel Controls and Indicators CAUTION Before applying power to the supply check the label on the heat sink to make certain that the supply s line voltage option agrees with the line voltage to be used If the option does not correspond to your line voltage refer to paragraph LINE VOLTAGE OPTION CONVERSION in the service section before applying power TURN ON CHECKOUT PROCEDURE a Connect line cord to power source and turn LINE switch on b Push 6V METER
3. cuit The 6V output current limit depends on the output termi nal voltage and varies linearly between 2 75 amps at 6 volts and 1 amp at zero volts All controls digital meter and output terminals are located on the front panel One voltage control sets the 0 to 6V and another sets the voltages of the O to 20V and 0 to 20V outputs simul taneously These dual tracking outputs are made more versatile by providing a tracking ratio control in addition to the usual volt age control With the tracking ratio control turned fully clockwise to its fixed position the dual outputs have a fixed 1 1 tracking ratio As the 20V voltage control is adjusted the voltage of the negative supply tracks the positive output within 1 Turning the tracking ratio control away from its fully clockwise position switches the dual tracking outputs into a variable tracking ratio mode In this mode the voltage of the negative output can be set lower than that of the positive output The tracking ratio control allows the negative supply s output to be set to any value between a maximum that is within 5 of the positive supply s output and a minimum that is less than 0 5 volts Once a ratio is established by the tracking ratio control the ratio of the positive output voltage to the negative output voltage remains constant as the 20V voltage control varies the O to 20V output over its range The front panel also contains a line switch three overload indicators
4. factory regulation at the load Each pair of connecting wires should be as short as possible and twisted or shielded to reduce noise pick up If a shield is used connect one end to the supply ground terminal and leave the other end unconnected If load considerations require locating output power distribu tion terminals at a distance from the power supply then the power supply output terminals should be connected to the remote distribution terminals by a pair of twisted or shielded wires and each load should be connected to the remote distri bution terminals separately Parallel Operation Two or more supplies can be connected in parallel to obtain a total output current greater than that available from one sup ply The total output current is the sum of the output currents of the individual supplies The output voltage controls of one power supply should be set to the desired output voltage and the other supply set for a slightly larger output voltage The supply set to the lower output voltage will act as a constant voltage source while the supply set to the higher output will act as a current limited source dropping its output voltage until it equals that of the other supply The constant voltage source will deliver only that fraction of its rated output current 1 8 necessary to fulfill the total current demand Series Operation Series operation of two or more power supplies can be accomplished up to the output isolation r
5. ON CONTRACT TORT OR ANY OTHER LEGAL THEORY ASSISTANCE The above statements apply only to the standard product warranty Warranty options extended support contacts product maintenance agreements and customer assistance agreements are also available Contact your nearest Hewlett Packard Sales and Service office for further information on HP s full line of Support Programs Manual Update The information in this manual update is provided to correct manual errors and to adapt the manual to instruments containing changes after the manual print date Manual Identification This update is used with the Operating and Service Manual of the E3630A Triple Output Lab Bench DC Power supply Manual Part Number 5959 5329 Manual Print Date August 1999 Edition 6 For Instruments with Serial Numbers gt KR71810198 Change 1 On page 1 5 change the Meter Accuracy Specification at the Table 1 as follows From 0 5 of full scale 2 counts at 25 C 5 C To 0 5 of output 2 counts at 25 C 5 C Copyright Hewlett Packard Company 1999 Printed in Korea August 1999 E0899 E3630 90092
6. cedures OPERATION This power supply can be operated individually or in parallel or series with another supply see Parallel and Series Opera tion paragraphs All output terminals are isolated from ground The 20V and 6V outputs use a single common out put terminal This common COM terminal or any one of the other output terminals may be grounded to the chassis at the front panel ground terminal 07 in Figure 2 or all outputs may be left floating Loads can be connected separately between each of the 0 to 20V output terminals and the COM terminal or between the 20V and the 20V terminals for a 0 to 40V output Each output voltage or current can be quickly selected for monitoring with the push button meter switches To moni 1 7 tor the 0 to 40V output voltage add the voltmeter readings of the 20V and 20V output and use either the 20V or the 20V meter to measure the current Tracking Ratio Control With the Tracking Ratio control in the Fixed position the volt age of the 20V supply tracks that of the 20V supply within 1 for convenience in varying the symmetrical voltages needed by operational amplifiers and other circuits using bal anced positive and negative inputs Turn the Tracking Ratio control counter clockwise out of the Fixed position to set the voltage of the 20V supply lower than that of the 20V supply The negative supply can be set from a minimum of less than 0 5 volts to a maximum within 5 of the
7. for 6V output 20V output and 20V output a voltmeter and an ammeter and three push button meter switches The push buttons select one of the supply s three outputs for display The voltmeter and ammeter always moni tor any one supply simultaneously In addition to the standard 115 Vac 10 47 to 63 Hz input two other line voltage options Table 1 AC INPUT Standard 115 Vac 10 47 63 Hz 115 VA 84 W OE9 100 Vac 10 47 63 Hz 115 VA 84 W OE3 230 Vac 10 47 63 Hz 115 VA 84 W DC OUTPUT and OVERLOAD PROTECTION 0 to 20 V Outputs Maximum rated output current is 0 5 A Short circuit output current is 0 55 A 5 and a fixed cur rent limit circuit limits the output of each supply to this maxi mum at any output voltage setting Unbalanced loads within current rating are permitted Q to 6 V Output Maximum rated output current is 2 5 A at 6 V The maximum available output current decreases with the output voltage setting A current foldback circuit limits the output to 2 75 A 5 at 6 volts and with decreasing voltage reduces the current limit linearly to 1 A 15 at zero volts short circuited TRACKING ACCURACY The 20 V and 20 V outputs track within 1 with the TRACKING ratio control in the Fixed position In variable tracking ratio mode the negative tracking output can be adjusted from less than 0 5 V to within 5 of the setting of the positive output LOAD REGULATION All Outputs Less than 0 01 plus 2
8. mV for a full load to no load change in output current LINE REGULATION All Outputs Less than 0 01 plus 2 mV for any line volt age change within rating PARD Ripple and Noise Less than 0 35 mV rms 1 5 mV p p 20 Hz 20 MHz Common Mode Current CMI Less than 1 uA for all outputs 20 Hz 20 MHz All Outputs are available for nominal inputs of 100 and 230 Vac The sup ply is furnished with a detachable 3 wire grounding type line cord The ac line fuse is in an extractor type fuseholder on the rear heat sink LINE FUSE The line fuse is located by the ac line receptacle Check the rating of the line fuse and replace it with the correct fuse if necessary as indicated below These are slow blow fuses Line Voltage Fuse HP Part No 100 115 Vac 1 6A 2110 0918 230 Vac 1 0A 2110 0599 SPECIFICATIONS Table 1 lists detailed specifications for the power supply Specifications 1 5 OPERATING TEMPERATURE RANGE 0 to 40 C for full rated output At higher temperatures out put current is derated linearly to 50 at 55 C maximum temperature TEMPERATURE COEFFICIENT All Outputs Less than 0 02 plus 1 mV voltage change per C over the operating range from 0 to 40 C after 30 minutes warm up STABILITY OUTPUT DRIFT All Outputs Less than 0 1 plus 5 mV dc to 20 Hz dur ing 8 hours at constant line load and ambient after an initial warm up time of 30 minutes LOAD TRANSIENT RESPONSE TIME All Outputs Less th
9. 1 8 REVERSE VOLTAGE PROTECTION 0cocccoccocccc cette aaa aaa 1 8 GENERAL INFORMATION INTRODUCTION This section contains general information concerning the E3630A triple output power supply Included are safety con siderations safety and EMC requirements instrument and manual identification option and accessory information instrument description and specifications SAFETY CONSIDERATIONS This product is a Safety Class instrument which means that itis provided with a protective earth ground terminal This ter minal must be connected to an ac source that has a 3 wire ground receptacle Review the instrument rear panel and this manual for safety markings and instructions before operating the instrument Refer to the Safety Summary page at the beginning of this manual for a summary of general safety information Specific safety information is located at the appropriate places in this manual SAFETY AND EMC REQUIREMENTS This power supply is designed to comply with the following safety and EMC Electromagnetic Compatibility require ments m IEC 1010 1 1990 EN 61010 1993 Safety Require ments for Electrical Equipment for Measurement Control and Laboratory Use m CSA C22 2 No 231 Safety Requirements for Electrical and Electronic Measuring and Test Equipment m UL 1244 Electrical and Electronic Measuring and Testing Equipment M EMC Directive 89 336 EEC Council Directive entitled Approximation of the Laws of the Member S
10. 20V supply s output Once this is done the 20V voltage control still controls both outputs and maintains a constant ratio between their voltages Overload Protection Circuits 20 Volt Current Limit The 20V and 20V outputs are indi vidually protected against overload or short circuit damage by separate current limit circuits to limit the output current to 0 55 A 5 This is 110 of the maximum rated output If a sin gle load is connected between the 20V and 20V outputs the circuit set for the lesser current limit will limit the output No deterioration of supply performance occurs if the output current remains below the current limit setting 6V Current Foldback The overload and short circuit pro tection circuit for the 6V output reduces the output current limit as the output terminal voltage decreases The operating region of the 6V output is enclosed by heavy lines in Figure 4 The maximum rated output current is 2 5 A and the current limit is factory adjusted to operate at 2 75 A 5 when the output is 6 volts At lower output voltages the circuit reduces the maximum obtainable output current linearly until 1 A 15 flows when the output is shorted The short circuit cur rent can not be adjusted NOTE During the actual operation of the 20V and 6V outputs if a load change causes the current limit to be exceeded the OL LED is lighted If overload conditions occur the 20V supplies will protect the l
11. It calls attention to an operating procedure or the like which if not correctly per formed or adhered to could result in damage to or destruction of part or all of the product Do not proceed beyond CAUTION sign until the indicated condi tions are fully understood and met CAUTION The NOTE sign denotes important infor mation It calls attention to a procedure practice condition or the like which is essential to highlight DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT Because of the danger of introducing additional hazards do not install substitute parts or perform any unauthorized modi fication to the instrument Return the instrument to a Hewlett Packard Sales and Service Office for service and repair to ensure that safety features are maintained Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel 1 2 Table of Contents SAFETY SUMMARY iiaa a A a ay ate ete a 1 2 GENERAL INFORMATION 0020 cece eee eee 1 4 INTRODUCTION ico ori a ee a Se ee ee eee ia 1 4 SAFETY CONSIDERATIONS ean ra na cern A ee patie beth pak pee 1 4 SAFETY AND EMC REQUIREMENTS oocococcoccc eee eee teens 1 4 INSTRUMENT AND MANUAL IDENTIFICATION 0 0000 00 cece eee eee eee 1 4 OPTIONS e wenn A 0 ey EY da ee ey BAD de Gy ev evel wwe ne a E a 1 4 AGCESSORY EAA a e Pane tabi betel a ZNAC BO SRM toot a 1 4 DESCRIPTI
12. ON ue nii ee ee ee ee ee a dA GAJA 1 4 UNE FUSE Sii a he AA abe Sule EE Babs Gale tok W AS 1 5 SPECIFICATIONS see 63 reiteriai ee A eee ee eee FA 1 5 INSTALLATION ea ale eae eee Dee eee ceri We eee ete ead 1 6 INITIAL INSPECTION ji a son Set ee hed ke elie en val Bae gala ee Re 1 6 Mechanical Check lt b tee ee ee Se i ee A 1 6 Electrical Check pce as keel oda Mechel bee aa 1 6 INSTALLATION DATA s s ae eee a a Ped ee ee ee ee A O 1 6 Location and Gooling e sg A WOP ane en ate WA ETA 1 6 Outline Diagram auauaaaaaaaeaaaaaeaaaana nana cana iii 1 6 Rack Mountindu cd on T OG A A dde a cdo eN e A 1 6 INPUT POWER REQUIREMENTS o0ccccoccoccocc ttt eee eee 1 6 Power Gable a hoe Mee ee ees ELU oo EE betes BOO eet 1 6 OPERATING INSTRUCTIONS 0 0 eens 1 6 INTRODUCTION ocaso te erie i Seine eid aig oye yin A ti Pi 1 6 TURN ON CHECKOUT PROCEDURE s psi primigeni ea tete aaa aaa aaa 1 7 OPERATION 20 bo 0 do da i nd ba aie Lied a ues e a kN 6 1 7 Tracking Ratio Control iius aeris ss ast aian a le aa Mal ld 1 7 Overload Protection Circuits 0 0 2 2 teens 1 7 Operation Beyond Rated Output 02 eee eens 1 7 Connecting Load ea ee oe ee ads Meee de kee el ie 1 8 Parallel Operation a AA A 1 8 Series Operation 0 6 A A A A WE 1 8 LOAD CONSIDERATIONS muane eee eee 1 8 PULSELOADINO iii ria a A REE 1 8 REVERSE CURRENT LOADING s oo uy reS nE aaa aaa aaa teens 1 8 OUTPUECAPACITANCES 2 A a
13. Us HEWLETT PACKARD TRIPLE OUTPUT POWER SUPPLY HP MODEL E3630A OPERATING MANUAL FOR INSTRUMENTS WITH SERIAL NUMBERS KR85014528 AND ABOVE For instruments with Serial Numbers above KR85014528 a change page may be included Manual Part No 5959 5329 August 1999 Edition 6 SAFETY SUMMARY The following general safety precautions must be observed during all phases of operation service and repair of this instrument Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the instrument Hewlett Packard Company assumes no liability for the customer s failure to comply with these requirements BEFORE APPLYING POWER Verify that the product is set to match the available line volt age and that the correct fuse is installed GROUND THE INSTRUMENT This product is a Safety Class instrument provided with a protective earth terminal To minimize shock hazard the instrument chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power cable with the third wire firmly connected to an electrical ground safety ground at the power outlet Any interruption of the protective grounding conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal injury If the instrument is to
14. an 50 usec for output recovery to within 15 mV of nominal output voltage following a load change from full load to half load or vice versa OUTPUT VOLTAGE OVERSHOOT All Outputs During turn on or turn off of ac power output plus overshoot will not exceed 1 V if the out put control is set for less than 1 V If the con trol is set for 1 V or higher there is no overshoot METER ACCURACY 0 5 of output 2 counts at 25 C 5 C METER RESOLUTION All Output Voltage DIMENSIONS 212 3 mmW x 88 1 mmH x 269 2 mmD 8 354 inW x 3 469 inH x 10 591 inD 10mV Current 10 mA WEIGHT 3 8 kg 8 4 lbs net 5 1 kg 11 3 lbs shipping INSTALLATION INITIAL INSPECTION Before shipment this instrument was inspected and found to be free of mechanical and electrical defects As soon as the instrument is unpacked inspect for any damage that may have occurred in transit Save all packing materials until the inspection is completed lf damage is found a claim should be filed with the carrier The Hewlett Packard Sales and Ser vice office should be notified as soon as possible Mechanical Check This check should confirm that there are no broken knobs or connectors that the cabinet and panel surfaces are free of dents and scratches and that the meter is not scratched or cracked Electrical Check Perform the TURN ON CHECKOUT PROCEDURE in the fol lowing paragraph to confirm that the supply is operational Alternately check the supply m
15. ating of any one sup ply to obtain a higher voltage than that available from a single supply Series connected supplies can be operated with one load across both supplies or with a separate load for each supply The power supply has a reverse polarity diode con nected across the output terminals so that if operated in series with other supplies damage will not occur if the load is short circuited or if one supply is turned on separately from its series partners When this connection is used the output volt age is the sum of the voltages of the individual supplies Each of the individual supplies must be adjusted in order to obtain the total output voltage LOAD CONSIDERATIONS This section provides information on operating your supply with various types of loads connected to its output PULSE LOADING The power supply will automatically cross over from constant voltage to current limit operation in response to an increase in the output current over the preset limit Although the preset limit may be set higher than the average output current high peak currents as occur in pulse loading may exceed the preset current limit and cause crossover to occur and degrade performance REVERSE CURRENT LOADING An active load connected to the supply may actually deliver a reverse current to the supply during a portion of its operating cycle An external source can not be allowed to pump current into the supply without risking loss of regulation an
16. be energized via an external autotransformer for voltage reduc tion be certain that the autotransformer common terminal is connected to the neutral earthed pole of the ac power lines supply mains DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Do not operate the instrument in the presence of flammable gases or fumes KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not remove instrument covers Component replacement and internal adjustments must be made by qualified service personnel Do not replace compo nents with power cable connected Under certain conditions dangerous voltages may exist even with the power cable removed To avoid injuries always disconnect power dis charge circuits and remove external voltage sources before touching components DO NOT SERVICE OR ADJUST ALONE Do not attempt internal service or adjustment unless another person capable of rendering first aid and resuscitation is present SAFETY SYMBOLS Instruction manual symbol the product will be marked with this symbol when it is necessary for the user to refer to the instruction manual Indicate earth ground terminal The WARNING sign denotes a hazard It calls attention to a procedure practice or the like which if not correctly per formed or adhered to could result inper sonal injury Do not proceed beyond a WARNING sign until the indicated con ditions are fully understood and met WARNING The CAUTION sign denotes a hazard
17. d possible damage to the output capacitor of the supply To avoid these effects it is necessary to preload the supply with a dummy load resistor so that the supply delivers current through the entire operating cycle of the load devices OUTPUT CAPACITANCE An internal capacitor across the output terminals of the supply helps to supply high current pulses of short duration during constant voltage operation Any capacitance added exter nally will improve the pulse current capability but will decrease the load protection provided by the current limiting circuit A high current pulse may damage load components before the average output current is large enough to cause the current limiting circuit to operate REVERSE VOLTAGE PROTECTION A diode is connected across the output terminals with reverse polarity This diode protects the output electrolytic capacitors and the series regulator transistors from the effects of a reverse voltage applied across the output terminals Since series regulator transistors can not withstand reverse voltage either diodes are also connected across them When operat ing supplies in parallel these diodes protect an unenergized supply that is in parallel with an energized supply ACTIVE LOAD DEVICE CURRENT FLOW DURING ty CURRENT FLOW DURING tR DO A Figure 4 Reverse Current Loading Solution 1 9 DECLARATION OF CONFORMITY according to ISO IEC Guide 22 and EN 45014 Manufactu
18. formerly National Bureau of Standards to the extent allowed by that organization s calibration facility and to the calibration facilities of other International Standards Organization members WARRANTY This Hewlett Packard hardware product is warranted against defects in material and workmanship for a period of three years from date of delivery HP software and firmware products which are designated by HP for use with a hardware product and when properly installed on that hardware product are warranted not to fail to execute their programming instructions due to defects in material and workmanship for a period of 90 days from date of delivery During the warranty period either HP or Hewlett Packard Company will at its option either repair or replace products which prove to be defective HP does not war rant that operation the software firmware or hardware shall be uninterrupted or error free For warranty service with the exception of warranty options this product must be returned to a service facility designated by HP Return to Englewood Colorado Service Center for repair in United States 1 800 258 5165 Customer shall prepay ship ping charges by and shall pay all duty and taxes for products returned to HP for warranty service Except for the products returned to Customer from another country HP shall pay for return of products to Customer Warranty services outside the country of initial purchase are included in HP s product price on
19. ly if Customer pays HP interna tional prices defined as destination local currency price or U S or Geneva Export price If HP is unable within a reasonable time to repair or replace any product to condition as warranted the Customer shall be entitled to a refund of the purchase price upon return of the product to HP The warranty period begins on the date of delivery or on the date of installation if installed by HP LIMITATION OF WARRANTY The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Customer Cus tomer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifica tions for the product or improper site preparation and maintenance TO THE EXTENT ALLOWED BY LOCAL LAW NO OTHER WARRANTY IS EXPRESSED OR IMPLIED AND HP SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE For consumer transactions in Australia and New Zealand The warranty terms contained in this statement except to the extent lawfully permitted do not exclude restrict or modify and are in addition to the mandatory rights applicable to the sale of this product to you EXCLUSIVE REMEDIES TO THE EXTENT ALLOWED BY LOCAL LAW THE REMEDIES PROVIDED HEREIN ARE THE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES HP SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSE QUENTIAL DAMAGES WHETHER BASED
20. oad by limiting the current to 0 55 A and the 6V supply will protect the load by reducing both voltage and current simultaneously along the foldback locus as shown in Figure 4 The 20V and 6V supplies are self restoring that is when the overload is removed or corrected the output voltage is automatically restored to the previously set value Operation Beyond Rated Output The supply may be able to provide voltages and currents greater than its rated maximum outputs if the line voltage is at or above its nominal value Operation can be extended up to 5 over the rated output without damage to the supply but performance can not be guaranteed to meet specifications in CURRENT MAY NARY 15 FROM UNIT TO UNIT NOTE THE LONER END POINT OF THE CURRENT LIMIT LING ISNOT ADJUSTABLE THE UPPER ENO POINT IS SET AT THE FACTORY FOR 2754 t 5 BETWEEN ITS ENO POINTS THE ACTUAL CURRENT UMIT IS A STRAKGHT UNE FUNCTION Figure 3 Current Limit Characteristic of the 6V Supply this region If the line voltage is maintained in the upper end of the input voltage range however the supply probably will operate within its specifications Connecting Load Each load should be connected to the power supply output terminals using separate pairs of connecting wires This will minimize mutual coupling effects between loads and takes full advantage of the low output impedance of the supply Load wires must be of adequately heavy gauge to maintain satis
21. ore fully using the PERFOR MANCE TEST in the service information section INSTALLATION DATA The instrument is shipped ready for bench operation Before applying power to the supply please read the INPUT POWER REQUIREMENTS paragraph Location and Cooling This instrument is air cooled Sufficient space should be allowed so that a free flow of cooling air can reach the sides and rear of the instrument when it is in operation It should be used in an area where the ambient temperature does not exceed 40 C Outline Diagram Figure 1 illustrates the outline shape and dimensions of the supply Rack Mounting This supply may be rack mounted in a standard 19 inch rack panel either by itself or alongside a similar unit Please see the ACCESSORY page 1 4 for available rack mounting accessory The rack mounting kit includes complete installa tion instructions INPUT POWER REQUIREMENTS Depending on the line voltage option ordered the supply is ready to be operated from one of the power sources listed in Table 1 A label on the rear heat sink shows the nominal input voltage set for the supply at the factory Power Cable To protect operating personnel the supply should be grounded This supply is equipped with a three conductor power cable The third conductor is the ground conductor and when the cable is plugged into an appropriate receptacle the supply is grounded The power supply is equipped at the factory with a power
22. rer s Name Hewlett Packard Company Korea Instrument Operation Manufacturer s Address 345 15 Kasan dong Kumchon ku Seoul 153 023 Korea declares the product Product Name Dual Output DC Power Supply Model Number HP E3630A Product Options All Options conforms to the following Product Specifications Safety IEC 1010 1 1990 EN 61010 1 1993 EMC CISPR 11 1990 EN 55011 1991 Group 1 Class A IEC 801 2 1991 EN 50082 1 1992 4 kV CD 8 kV AD IEC 801 3 1984 EN 50082 1 1992 3 Vim IEC 801 4 1988 EN 50082 1 1992 1 kV Power Lines 0 5 kV Signal Lines Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC inclusive 93 68 EEC and carries the CE mark accordingly The product was tested in a typical configuration with Hewlett Packard Test Systems Seoul Korea May 10 1996 Young Sook Lee Quality Manager European Contact Your local Hewlett Packard Sales and Service Office or Hewlett Packard GmbH Department ZQ Standards Europe Herrenberger Stra e 130 D 71034 B bligen FAX 49 7031 143143 Us HEWLETT PACKARD CERTIFICATION Hewlett Packard HP Company certifies that this product met its published specifications at time of shipment from the fac tory Hewlett Packard further certifies that ts calibration measurements are traceable to the United States National Institute of Standards and Technology
23. switch and with no load con nected vary 6V VOLTAGE control over its range and check that the voltmeter responds to the control setting and the ammeter indicates zero c Set the 6V VOLTAGE control to 6 volts and short the 6V output terminal gt to COM common terminal 5 with an insulated test lead The ammeter should indicate a short circuit output current of approximately 1 0 A Remove the short from the output terminals d Push the 20V METER switch and turn Tracking Ratio control fully clockwise to the Fixed position With no load connected vary 20V VOLTAGE control over its range and check that the voltmeter responds to the control setting and the ammeter indi cates zero e Set the 20V VOLTAGE control to 20 volts and short the 20V output terminal 0 to the COM terminal with an insulated test lead The ammeter should indicate a short circuit output current of 0 55 A 5 Remove the short from the output terminals f Repeat steps d and e for 20 V output g Adjust the 20V output to 20 volts Then push 20V METER switch and check the effect of the Tracking Ratio control on the voltage of the 20V output The 20V output should be adjustable from less than 0 5 volts to a maximum of 19 to 21 volts If this brief checkout procedure or later use of the supply reveals a possible malfunction see the service information section for detailed test troubleshooting and adjustment pro
24. tates relating to Electromagnetic Compatibility m EN 55011 1991 Group 1 Class B CISPR 11 1990 Lim its and Methods of Radio Interference Characteristics of Industrial Scientific and Medical ISM Radio Fre quency Equipment EN 50082 1 1992 IEC 801 2 1991 Electrostatic Discharge Require ments IEC 801 3 1984 Radiated Electromagnetic Field Requirements IEC 801 4 1988 Electrical Fast Transient Burst Requirements INSTRUMENT AND MANUAL IDENTIFICATION A serial number identifies your power supply The serial num ber encodes the country of manufacture the week of the lat est significant design change and a unique sequential number The letter KR designates Korea as the country of manufacture the first one digit indicates the year 3 1993 4 1994 and so forth and the second two digits indicate the week The remaining digits of the serial number are a unique five digit number assigned sequentially If the serial number on your supply does not agree with those on the title page of the manual a yellow Change Sheet is supplied with the manual to explain the difference 1 4 between your instrument and the instrument described by this manual The Change Sheet may also contain information for correcting errors in the manual OPTIONS Options OE3 and OE9 determine which line voltage is selected at the factory The standard unit is configured for 115 Vac 10 47 63 Hz input Option No Description OE3 230 Vac