1. Set new ON or OFF time See To Set Programs To Override Automatic Operation Press MANUAL key to move indicator bar to the desired ON or OFF position Note Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO TROUBLESHOOTING Possible Cause s Symptom Blank Display Timer will not respond to programming Timer will not function as programmed Timer is ON at all times Discharged battery Defective timer Memory is full Timer is in ON mode Defective timer Defective relay Corrective Action cae ae a ee eS Connect to power source Serre r errr ee Replace timer pp aeuenateese Press to clear memory Timer is in MANUAL mode Press MANUAL key and move indicator bar over to AUTO oe Ae See eee See above pee ataane eae Replace timer err Cr TT eee Replace relay
2. Press DAY key to choose any of 15 different day combinations for the first ON time Note Days of the week having the same program should be copied by selecting the desired combination of days Press the HOUR key and then the MINUTE key to select the desired first ON time Press TIMER key once Display will show 1 OFF Repeat previous step to select the desired first OFF time Repeat the entire sequence to complete up to eight total ON OFF times as desired When programming is done press the CLOCK key then the MANUAL key repeatedly until the indicator bar is above the word AUTO To Review Program Press TIMER key repeatedly When done press CLOCK key to return to the time of day To Cancel Change Part of the Program Press TIMER key repeatedly until the particular ON or OFF time appears then repeatedly press the DAY key until Contact a qualified service technician In case this device is used to operate pool spa equipment DANGER To Reduce the Risk of Injury do not permit children to operate the Control Unit or use the Pool Spa unless they are closely supervised at all times test GROUND FAULT protection regularly If it fails to reset DO NOT USE THE POOL or SPA V7 ANTERMATIC Display Reset port to cancel all prior settings ON AUTO OFF Select Key Indicator LED ON when connected to power source and contacts are closed Function Keys the display shows
3. FIELD WIRING Model P7101ME 120 Volt NTERMATIC INSTALLATION Model P7102ME 240 Volt P7000 SERIES OPERATION amp TIME CONTROLS SERVICE MANUAL Installation Installation a x 5 a E E E 3 2 7 3 a 3 Model P7000ME Series Electronic Time Control Mechanisms a U D 4 lel ale IMPORTANT SAFETY INSTRUCTIONS els S ENE s sS When installing and operating this Product and other associated equipment basic safety precautions should always be followed 2 2 7 1 including the following Eare _ Note From 240V To 240V 1 This Control must be installed by a qualified electrician according to the National Electrical Code Including Article 680 and Sippy ee Ground Supply oad Local Electrical Codes USE COPPER CONDUCTORS ONLY If applicable install this Control not less than 5 feet from inside edge of pool or spa Do not exceed the maximum ratings of individual components wiring devices and current carrying capacity of conductors For grounding of the installation refer to Article 250 and 680 of the National Electrical Code This Control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly Always disconnect electricity at main panel before servicing this Control or the equipment connected to it THIS CONTROL IS NOT TO BE USED AS A POWER DISCONNECT READ FOLLOW AND SAVE THIS INSTRUCTION MANUAL GENERAL INFORMATION S 1 These electron
4. ic modular timers are designed to O control electric appliances and equipment on a 7 day schedule They can turn ON and OFF the connected load connections are not shown Model P7103ME 120 Volt Model P7103ME 240 Volt oOo O1 amp GC PO Installation Installation Black White Blue Yellow White Black Red Blue o S Ela Sala J gt up to eight times daily and repeat the daily program 15 i 2 S 2 ss different ways The timers are completely enclosed and Ld L o Lo when fully charged the internal battery will hold up the From 120V To 120V From To 240V Supply aa 120 240V aca memory for at least 100 hours Supply Model P7000ME series timer mechanisms are made to fit any Intermatic indoor or outdoor metal or plas tic enclosure and service panels They are intended to replace older mechanical timers and also can be installed in service panels as retrofits These timers are compatible WARRANTY with Intermatic s RC series remote controls lf within one 1 year from the date of installation this product fails due to a defect in material or workmanship Intermatic Incorporated will repair or replace it free of charge The warranty does not cover labor for removal or reinstallation and does not apply to a damage caused by accident abuse mishan dling or dropping b a unit which has been subject to unauthorized repair c units not used in accordance with directions d damages Model V
5. oltage Contacts _Rating HP 1 P7101ME 120 P7102ME 240 3 P7103ME 120 240 exceeding the cost of the product Some states do not allow a limitation of damages so the foregoing warranty may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty service is available if the defective product or its defective component is returned with proof of purchase and date of installation either a to the dealer from whom the unit was purchased or b by shipping prepaid to the Intermatic Service Center Intermatic All Models 20A Resistive 120 or 240V 10 A Tungsten 120V Incorporated Intermatic Plaza Spring Grove IL 60081 9698 Because of our commitment to continuing research and improvements Intermatic Incorporated reserves the right to make changes without notice in the specifications and material contained herein and shall not be responsible for any damages direct or consequential caused by reliance on the material presented INTERMATIC INCORPORATED SPRING GROVE IL 60081 9698 http 7 www intermatic com 15819898 A 1 SPECIFICATIONS Timer Microprocessor based 7 day clock Power Consumption SVA Battery Reserve 100 Hours minimum Minimum Interval 1 Minute of Programming Periods 8 ON 8 OFF Repeat Programs M T W Th F Sa Su different each day M T W Th F Sa Su same every day M T W Th F same on weekdays Sa Su same
6. on weekends M T W Th F Sa M W E T Th Sa Th F Sa INSTALLATION AND INTERNAL WIRING Make sure the intended load is within the capacity of the Timer see ratings on page 1 1 Select the proper location see Important Safety Instructions on page 1 for the proper enclosure of your choice and install it on a vertical surface or other support using hardware suitable for the purpose 2 Prepare the necessary conduit runs as required by the installation layout and pull in the specified conductors 3 Install timer mechanism in enclosure and follow wiring diagram on page 4 make wire connections as shown 4 Turn ON power and test installation using the MANUAL button on face of the Timer Replace wiring compartment cover make sure the installation is secure and raintight Red 5 Set Timer see Operating Instructions on page 3 mmm x lt ab a b E pS ofe sjLl CO ab ma CO ab gt CO gt 120V Timer Black White 120V Relay C 1 C 1 Black Red SETTING OPERATING INSTRUCTIONS Programming Instructions To Set or Change the Day and Time To clear entire memory press R key Hold down the CLOCK key while pressing either the DAY HOUR or MINUTE keys Continue pressing until the desired day or number is shown Then simply lift finger off the CLOCK key to set To Set Program ON OFF times Press TIMER key once to enter into program mode Display will show 1 ON