Programming Insert: 5600SE Upflow - Archive (41675)

image

Contents

1. 4 5 6 Depress the Extra Cycle Button The next 2 4 displays viewed are part of a series of option settings used to program the Regeneration Cycle Up to 4 steps can be programmed Each display is used to set the duration time in minutes or tenths of minutes Metric of that specific step in a regeneration cycle A step will turn on for the regeneration cycle step being programmed Regeneration steps are skipped by setting the display to 0 and regeneration ended by setting the step after the last active step to OFF as shown below and on the next page Examples Regeneration Cycle Step 1 8 minutes 8 Regeneration Cycle Step 3 skipped 3 620 Page 3 Printed in U S A MODEL 5600SE Upflow V2 0 Master Programming Mode Cont d 6 Regeneration Cycle Step Programming 1 2 3 4 5 6 Cont d Examples Regeneration Cycle Step 4 cancelled 40F F Regeneration Cycle Step 4 8 5 minutes 4 8 5 Metric Format Depress the Extra Cycle Button once per display to advance through Regeneration Cycle Step Programming The 5600SE control has a separate brine tank fill cycle Your desired salt setting must be calculated using the blue 25 gpm or black 5 gpm rate of refill in gpm times your timer setting Then using one gallon of fresh water dissolving approximately 3 Ibs of salt calculate your refill time Example lbs salt 3 B L FC Size refill time in minutes 10 Ibs salt 3 2
2. 5 13 3 minute refill The Set UP and DOWN Buttons will adjust these values 7 Flow Meter Size F Depress the Extra Cycle Button The next display is used to set the flowmeter size This option setting is identified by the letter F in the first digit In this display set the proper amount of pulses generated by the flow meter for each gallon or liter of water flow This setting will not be viewed with Timeclock Regeneration Type selected Examples F133 3 4 Turbine Flow Meter US Format F3 5 3 4 Turbine Flow Meter Metric Format The Set UP and DOWN Buttons will adjust this value 8 Valve Type 0 Depress the Extra Cycle Button This display is used to set the type of valve used with the control This option setting is identified by the letter o in the first digit There are two possible selections with 1 being the required setting Examples 5600SE Valve Operation o 2 Option Not Typically Used The Set UP and DOWN Buttons will adjust this value 9 Line Frequency LF Depress the Extra Cycle Button This display is used to set the frequency of the power applied to the control When properly set all timekeeping functions will remain accurate This option setting is identified by the letter o in the first digit There are two possible selections Examples LF50 50Hz Line Frequency Operation L F 60O 60Hz Line Frequency Operation The Set UP and DOWN Buttons will adjust this value E
3. MODEL 5600SE Upflow V2 0 Master Programming Mode Flow Chart Note 1 SetTimeofDay Display to 12 01 P M 2 Push and hold both the Set Up and Down Buttons for 5 Seconds 3 Push Extra Cycle Button once per display until all displays are viewed and normal operation is resumed 4 Option setting displays may be changed as required by pushing either the Set Up or Down Button 5 Depending on current valve programming certain displays will not be able to be viewed or set DF047 0 oe Printed in U S A With Time of Day Display set to 12 01 P M Push and hold both the Set Up and Set Down Buttons for 5 seconds US Metric Display Format Example US Display Format U 1 Regeneration Type Example Metered Delayed Regeneration 7 3 Treated Water Capacity Example 1 000 Gallons 1000 Regeneration Time Example Regenerate as needed at 2 00 A M 2 00 Regeneration Day Override Example Regenerate at a minimum frequency of 3 days A 3 Regeneration Cycle Step 1 Example 10 minute step time 1 10 Regeneration Cycle Step 2 Example 60 minute step time 2 60 Regeneration Cycle Step 3 Example 10 minute step time 3 10 Regeneration Cycle Step 4 Example 12 minute step time 4 12 Regeneration Cycle Step 5 Example Step 5 Cancelled SOFF Flow Meter Size Example 5600SE 3 4 Turbine Flow Meter F133 Valve Type Example 5600SE Valve o 1 L
4. ery 700 gallons liters or m 700 The Set UP and DOWN Buttons will adjust this value 4 Regeneration Time No display Code Depress the Extra Cycle Button The next display viewed is the option setting for Regeneration Time It is identified by a non flashing colon between two sets of numbers Set the desired time of day that a regeneration may occur if required This display will not be viewed with Meter Immediate Regeneration Type set Example 2 o clock A M regeneration time 2 00 A M Indicator Dot On The Set UP and DOWN Buttons will adjust this value 5 Regeneration Day Override A Depress the Extra Cycle Button This display is used to set the maximum amount of time in days the unit can be in service without a regeneration This option setting is identified by the letter A in the first digit With Meter Immediate Regeneration Type selected regeneration will begin at the same point in time some amount of days ago when the last regeneration cycle was initiated With Timeclock or Meter Delayed Regeneration Types selected regeneration begins at the set Regeneration Time An OFF setting will cancel this feature with all regeneration types except Timeclock Regeneration were it must be used Examples Override every 7 days A 7 Cancel setting AOFF Meter Immediate or Delayed Regeneration Types Only The Set UP and DOWN Buttons will adjust this value 6 Regeneration Cycle Step Programming 1 2 3
5. ine Frequency Example 60Hz Line Frequency LF60 Master Programming Mode is exited Normal Operation is resumed Page 1 MODEL 5600SE Upflow V2 0 Master Programming Mode Service Program e U niiz Program Indicator Set Up Button Extra Cycle Button Set Down Button Regeneration Display Step 1 Brine Rinse Step 3 Rapid Rinse Step 4 Brine Refill Step 2 Backwash Entering Master Programming Mode With Time of Day Display set to 1201 PM push and hold for 5 seconds both the Set Up and Down Buttons The Program Indicator will turn on to signal that this mode is entered In this mode all possible option settings may be viewed 1 US Metric Display Format U Depress the Extra Cycle Button This display is used to set the desired display format This option setting is identified by the letter U in the first digit There are two possible settings US Format uses gallons for volume with a 12 hour timekeeping format Regeneration timing in minutes Example U I Metric Format uses liters for volume with a 24 hour timekeeping format Regeneration timing in tenths of minutes Example U 2 Cubic Meter Format uses m for volume with a 24 hour timekeeping format Regeneration timing in tenths of minutes Example U 4 The Set UP and DOWN Buttons will adjust this value Regeneration Type 7 Depress the Extra Cycle Button This display is used to set the Regeneration Ty
6. pe This option setting is identified by the number 7 in the first digit There are 3 possible settings Timeclock Delayed The control will determine that regeneration is required when the set Regeneration Time has been reached The Regeneration Day Override setting will determine which days a regeneration cycle will be initiated Example 7 Meter Immediate The control will determine that regeneration is required when the available volume of softened water drops to or below zero Regeneration to begin immediately Example 7 2 Page 2 Printed in U S A MODEL 5600SE Upflow V2 0 Master Programming Mode Cont d 2 Regeneration Type 7 Cont d Meter Delayed The control will determine that a regeneration is required when the available volume of softened water drops to or below zero Regeneration is to begin immediately at the set Regeneration Time Example 7 3 The Set UP and DOWN Buttons will adjust this value 3 Treated Water Capacity No Display Code Depress the Extra Cycle Button This display is used to set the amount of treated water gallons liters that can be produced by the unit before a regeneration cycle is required With Meter Delayed Regeneration Type set it will be up to the programmer to determine a reserve capacity and subtract that value from the calculated full capacity of the unit This display will not be viewed with Timeclock Regeneration Type set Example Regenerate ev
7. xiting This Option Setting Level Push the Extra Cycle Button once per display until all have been viewed The Program Mode will be exited and normal operation resumed Resetting Permanent Programming Memory Push and hold the Set Up and Down Buttons for 25 seconds or until the Time Of Day Display resets to 12 00 P M All option settings will then reset to default values Control programming will then have to be reset as necessary Page 4 P N 41675 Rev A Printed in U S A