Home

4 - Navair Inc.

image

Contents

1. This testing provides an accurate quantitatrve measurement of modulation quality and overall system performance Feature Benefits Dynamic Call Testing of Subscriber Radios Project 25 compatible FDMA Digital C4FM modulation and demodulation on trunked channels allows testing of radio registration process and ability to receive call alert indication These features also permit testing of trunked radio capabilities such as a transition to a traffic channel from a control channel quality of radio transmitted signal as well as voice quality The operator can verify both radio system compatibility and functionality without having to rely on an actual system for confirmation In addition precise radio performance and programming data ensure operation within appropriate system performance specifications Closed Cover Measurements Measurements can be made while a simulated live call is maintained with the radio under test This affords the user greater diagnostic capability to ensure proper radio operation with just a single RF connection to the radio Full Duplex Test of Base Station Repeaters Project 25 compatible FDMA digital C4FM modulation of 1011 Hz test pattern with simultaneous C4FM LSM demodulation of voice Performs average power level measurements under actual operating conditions with a Selectable averaging interval This feature allows the operator to monitor transmitter power levels under traffic conditions
2. You can verify both radio system compatibility and basic functionality without using valuable airtime for testing This feature also allows you to test in areas that are beyond the range of an actual system By obtaining precise measurements of radio performance data you can be sure that your system is operating with the proper margin This feature ensures compatibility with SMARTZONE system operation The simultaneous control channel allows you to redirect a radio to the traffic channel upon temporary loss of signal Testing all channels within a band also helps you ensure adequate performance margin This feature affords you greater diagnostic capability to ensure proper radio operation Closed Cover Measurements Transmitter power frequency and deviation are measured within the dynamic calling mode and displayed on the signaling screen all with a single RF connection to the radio Additional measurements can be made on other screens while the simulated live call is maintained Radio ID information is decoded in either hex or decimal format You can verify radio specification performance and programming quickly and easily without opening or removing the radio to activate a special test mode Dedicated Trunking Screens Conveniently accessed dedicated test screens can be set up as a start up default condition or a programmable test set up Dedicated Trunking test screens are windowed with RF and Modulation control scre
3. High Pass Filters 5 Hz 300 Hz 3 kHz 0 8 V peak per 10 AM modulation 100 ohms nominal TRUNKING OPTIONAL FEATURE Signaling Types Call Sequence Tests Trunking Test Parameter Entries Test Measurement Display Radio ID Decoding Smart Zone Test Support Frequency Bands Channel Plan Entry for VHF UHF SMARTNET SmartZone Type Type EP Il Type II ASTRO VSELP IMBE ASTRO testing in the Trunked mode is limited to functional verification of operation on a traffic channel More detailed testing of Data BER and Encryption are done in conventional mode through use of the ASTRO diagnostic options Dispatch Phone Interconnect Call Alert Failsoft Dependent on Test Selection Signaling Type Call Sequence System ID Size Code Connect Tone Frequency Band Control and Traffic Channel by frequency and channel number Call Sequence Status Indicator Radio ID Hex or Decimal Call Type RF Performance Data via exit to standard screens Type Fleet Sub fleet amp Unit ID Type Il Talk Group Unit ID Auto affiliation test 851 870 MHz 866 870 MHz Split Channel 935 941 MHz 850 860 MHz JSMR 403 522 MHz UHF 132 175 MHz VHF Separate transmitter and receiver start and end frequency for three blocks Independent channel spacing for each block 11 DIAGNOSTIC OPTIONS SPECIFICATIONS Cont Voice Testing EMBEDDED SIGNALING Encode Capability Encode Operator En
4. TONE SEQUENCE DECODE Modulation types PRIVATE LINE DIGITAL PRIVATE LINE Single Tone DTMF Two Tone Paging 5 6 Tone Paging International Select V 20 Tone General Sequence 3 from 300 Hz to 3 kHz 12 msec for tones greater than 30 msec and 300 Hz Frequency 10 MHz Aging rate 0 05 ppm yr Temperature stability 0 01ppm 0 to 50 C Frequency Accuracy Duration Accuracy TIME BASE INTERFACE PORTS Printer Remote Control Color Monitor RS 232 Bend rate up to 115 2 kbps Standard 15 pin VGA POWER amp ENVIRONMENT AC 100 to 130 VRMS or 200 to 260 VRMS 50 Hz to 440 Hz DC 11 to 16 VDC 10A Fused Battery Option 13 6 V 50 minutes typical Dimensions 8 5 high x 16 wide x 17 deep 21 6 cm x 40 7 cm wide x 43 2 cm excluding accessories battery pack and cover 28 5 Ibs base unit without cover options or accessories 0 C to 50 C operating 40 C to 85 C storage Weight Temperature 13 Model Nomenclature and Ordering Guide Base Models R2600D R2625C R2670B R2680B Standard Unit for general purpose 2 way testing Standard Unit configured for Project 25 Test Capability including DES OFB encryption Enhanced Standard Unit for ASTRO Project 25 SMARTNET SmartZone and or SECURENET test options MPT1327 1343 Equipped Communication System Analyzer Options Matrix Order as additional Line items with base Model Standard Options Description Tracking Generator
5. Australian Support Center Motorola Australia Pty Ltd 10 Wesley Court Tally Ho Business Park East Burwood VIC 3151 Australia Phone 61 3 9847 7725 Fax 61 3 9847 7755 GCE in its products and specifications at any time and without notice GENERAL DYNAMICS SATCOM Technologies 1915 Harrison Road Longview TX 75604 Hudson 5474 550 11 07 Telephone 903 295 1480 Fax 903 295 1479 Email cte gdsatcom com Please visit our web site at www gdsatcom com cte html to find the representative in your area All trademarks indicated as such herein are trademarks of General Dynamics Reg U S Pat amp Tm Off All other product or service names are the property of their respective owners 2007 General Dynamics All rights reserved General Dynamics reserves the right to make changes
6. If a high power transmitter should be keyed into the unit for any longer the LCD changes to read WARNING RF OVERLOAD thus warning the technician to un key This feature provides calibrated RF power measurements eliminating the need for a separate wattmeter The LCD also displays frequency error and modulation level readings simultaneously Programmable Test Memory Channel Presets The unit has 30 memory locations which can be used to store preset channel information Channels can readily be selected individually or automatically scanned over a user defined range Programmable Test Setups standard in R2670 optional in R2600 and R2625 You can easily program and store up to 15 of the most commonly used test configurations including all test conditions measurement display formats and levels These memory settings operate independently of the channel presets Channel Presets This feature allows quick access to frequently used channel location information to speed testing Scanning allows automatic monitoring and measurement of activity on channels of interest Programmable Test Setups standard in R2670 optional in R2600 and R2625 You can significantly reduce the number of key presses required to set up more commonly used test configurations greatly increasing your efficiency while promoting uniform test procedures You can also assign a custom name to the configuration for easy recall Standard System Featu
7. RVN5013B XTS3000 5000 RVN5016B ASTRO SPECTRA RVN5024B ASTRO SPECTRA PLUS RVN5025B ASTRO SPECTRA SPECTRA PLUS RVN5026B AUTO TEST SUITE RVN5027B includes RVN5016B amp RVN5026B Vertex Standard VX P820 920 202621 01 Z i AaTIIraQ a p L l N Ld u d k A i Feature Benefits ligh Performance Spectrum Analyzer The built in High Performance Spectrum Analyzer will display a window of RF spectrum anywhere within the 400 kHz to 1 GHz operating range of the unit The EXPAND softkey enlarges the display to fill the LCD and retains dispersion and center frequency control The High Performance Spectrum Analyzer adds Marker functions for more precise measurements of level and frequency both absolute and delta Included with the marker functions are additional dispersion selections up to 10 MHz per division plus the additional freeze peak hold and max hold features The ability to observe the spectrum display for detailed analysis through the use of multiple Markers provides a significant advantage The tuning knob retains control of the center frequency even in the EXPAND mode to perform fast sweeps or fine tuning This allows you to quickly locate and identify signal carriers erminated RF Wattmeter RF power anywhere in the operating range of 400 kHz to 1GHz is automatically measured by the Communications System Analyzer when tuned to that frequency The built in RF load dissipates up to 125 watts for one minute
8. are stored for easy retrieval Now even non technical personnel can fully test and align your radios freeing technicians to do actual repairs P25 conventional equipped R2670 Benefits Features e A typical radio alignment can be completed in less than 10 minutes e Program automatically reads the radio s parameters and configures the analyzer to significantly reduce operator intervention e Pass Fail indication reveals defective radios e Standard Windows interface makes AutoTest simple and intuitive to operate e No technical expertise required e All results are automatically saved to disk and can be viewed and printed at any time e Utilizes the R2670 or R2625 Communication Systems Analyzer for dependable performance e Alignments and performance tests are performed according to manufacturer s specifications e Allows consistent alignment from radio to radio Tests Alignments Performed Aliqnments e Reference Oscillator e Transmitter Deviation Balance e Transmitter Deviation Limit e Bit Error Rate BER e Reference Frequency e RF Output Power e Rated Audio e Distortion e SINAD Sensitivity e Noise Squelch e Voice Modulation External e Voice Modulation Internal Minimum Requirements for Communications System Analyzer R2670A B J LS e red option CM701 CM713 or CM801 CM813 V6 08 R2625A B C None V6 08 Ordering Information XTS3000 RVN5012B XTS5000
9. 12800 2 0 FELE a7 a7 a Pars G24 907500 2 86 2 05 78 38 Sub Aud Dev Fasa 51 012500 z 86 2 86 44 44 wudo Deviation Pass 860 012600 2 87 2 30 a7 46 Pare 86869 907500 2 04 2 07 40 40 Transmit Deviation Limit Aligneant Result Freq A Deviie kHs Mewioftpoet Oldzoftpoe l mi Overall Progress Pass B0G 012800 2 84 52 52 Model umber 2 P84 e a Pass lp OLZ500 2 05 Ft 52 Saint Al Clear Al Test Only Fass 8824 587509 z a4 53 53 Serial Number 170423 i Align ami Test E Pass 8851 012500 2 84 53 53 ZL f Poss B60 012800 88 3 Bl Adjusting RX Tune tid Softpot gt Automated Test and Alignment AutoTest and AutoTune perform all recommended factory alignment procedures and critical transmitter receiver performance tests in a fraction of the time it takes to perform manually oh _ w i J 7 i Tt Tt f f i l Fast accurate easy to use The AutoTest and AutoTune software applications takes the guesswork out of aligning your radios Simply connect the radio select the tests and or alignments you wish to perform from the menu and press Run The software automatically reads the radio s internal programming configures the analyzer and takes measurements as needed If required internal radio adjustments are then automatically performed to bring the radio into proper alignment All measurement results and initial final softpot settings
10. 5 10 19 694 CF Co NAC HS IC ioc 8 DUID s 3 Term LC 80 00 B9 ss 000 15 11 08 487 toO Tr NAC S woo ae MFID 00 RESERVED operation in conformance to the standard Gis ag performance the symbols that are sent and received are logged and can be saved and recalled for later analysis The Channel Logging PC application also provides a filter that allows the user to show only what is relevant to the task at hand Irii eee S50 Ble Gat Conga Dagis Hep BBM RRL CY Pack P E 29 17 oye 35 30 35 40 45 50 55 AD aS IO 75 ED m aor pea al 4 b EA p ha eli mi E E l 3 i j Auto Test Auto Tune For Digital P25 Equipped Radios ASTRO MTS2000 Radic Alignment Report GENERAL DYNAMICS a E gt ai antes Serial J26AAWJS47 Date Time 11 19 2009 13 00 Rado ake amp Model Bedel f HOFUCHIPWTEN Operator ID JES Hoteecton Feterence Oscillator Alignment Result Fereq HHs Error Ha Hevioftpon OldZofupat Fare 6863 3967500 Lio 63 103 Motorola X755000 Vertex Staigiai VA FEJO Paci Getera Cynaccs OM 200 faise Genera roms OM 200 Trancsrlter Transmit Deviation Balance Compensation Aligrmant SPSS SP SS SPS E STS SPSS SSP SP SSS Pes Sees Ferule Freq Mis Leber kHs Hibey kHe MaewSoftpet Oldtetepor Pass pis 012500 2 86 2 EJ 26 26 Pars G816 0
11. Communications System Analyzers The New R2600 Series including R2600 R2625 and R2670 soo000000 a O a a If you maintain repair calibrate or design radio the R2600 is designed to help you save time and work communications equipment the R2600 family of more efficiently This platform is available in three models Communications System Analyzers has a solution for each tailored to its own set of testing requirements you Rugged enough to withstand heavy field use GENERAL DYNAMICS SATCOM Technologies Features Benefits 1 Display Zone for presentation of test data and waveforms 2 RF Control Zone for selecting RF test conditions 3 Cursor Zone keys provide simple one button access to any zone 4 Tuning Knob for quick and easy changes of numeric entries Digital precision with an analog feel 5 Off the air antenna port for sensitive receiver measurements 6 Color LCD 7 VGA output port 8 High speed serial port for remote control operation and flash software update capability 9 User friendly soft touch keys for feature selection 10 Audio Control Zone for setting modulation conditions 11 Cursor position keys allow instant cursor movement within a zone 12 Memory recall for up to 30 channels including automatic scanning plus optional 15 user programmable test setups 13 One button access to special functions 14 Hard rubber bumpers on front and rear for maximum physical integrity 15 Rubberized kno
12. Number R2600 Encryption Options Select any combination Requires M711 CM712 or CM713 CM807 CM808 CM709 CM710 NA NA NA NA Accessories Supplied May also be ordered separately Oscilloscope Probe BNC to N Adapter DC Power Connection Kit Telescoping Antenna 90 Degree BNC for Antenna Microphone Signal Generator Termination 50 ohm Operators Manual on CD Power Cord Spare RF Fuses BNC RF T RF Detector Probe Additional Accessories Order Separately Canvas Carrying Case Hard Sided Transit Case w wheels Isolation Transformer for baseband output Isolation Transformer for baseband output RF Detector probe with 50 ohm termination Programmers Reference Manual Service Manual on CD RTL4011A 9884300A98 RPX4097A TSBN M55339 14 003 50 P26922A001 28 P29965H104 CCW353 GG6530277C002 31 2208 RLN4748A 1580357B77 202620 01 0180302E83 0180302E82 9880345B96 6880309E55 RLN5237A Portable Power Pack for R2600 Analyzers 6880386B72 R2625 R2670 Optional Optional NA Optional NA Optional NA Optional x 6880309J83 6880309F17 Notes Requires CM813 Requires CM711 Requires CM711 Requires CM711 Required for cable fault testing Required for cable fault testing Protects unit when used in the field Shipping Protection Isolate output signal from chassis ground Isolate input signal from chassi
13. RLN5069 Cable Fault RLN4306 Programmable Test Setup Memory RLN4485 IEEE 488 2 Remote Interface RLN4329 C Message Filter with 600 ohm load RLN4034 CCITT Filter with 600 ohm load RLN4361 Phase Mod Demod RLN4484 Analog Trunking Options Select Only One SMARTNET SmartZone RLN4498 SMARTNET SmartZone with ASTRO trunking RLN4497 Diagnostic Test Options Digital Hardware Module CM701 Enhanced Digital Hardware Module CM801 Part Number R2600 Optional Optional Optional Optional Optional Optional Optional NA NA NA NA Transmission Formats Select any combination Required for Advanced P25 Options Securenet CM711 NA ASTRO VSELP Vocoder CM712 NA Project 25 with DES OFB encryption CM813 NA Project 25 Trunking CM814 NA Advanced Project 25 Options Require CM813 Channel Logging EVM 14 CM815 CM816 Model Availability R2625 R2670 Notes Optional Standard Optional Standard Includes RF Detector Probe and T Optional Standard Optional Optional Optional Optional Optional Optional Optional Optional NA Optional NA Optional VSELP IMBE Compatible NA Optional Required for ASTRO VSELP Incl Optional NA Optional Requires CM701 or CM801 NA Optional Requires CM701 Standard Optional Requires CM801 Optional Optional Requires CM801 Requires CM813 May be ordered individually Requires CM813 May be ordered individually Hard Sided Transit Case with Wheels Description AES DES DES XL DVP XL DVI XL Part
14. bs The R2600 Series The industry proven test solution for APCO Project 25 Project 25 SMARTNET SmartZone ASTRO SECURENET and conventional two way radio The R2600 family of Communications System Analyzers performs tests normally associated with these instruments e RF Signal Generator e Sensitive Measurement Receiver e Spectrum Analyzer e Full Band Duplex Offset Generator e Frequency Counter e AC DC Voltmeter e 50 kHz Oscilloscope e RF Wattmeter e Signal Strength Meter e Frequency Error Meter e SINAD Meter e Distortion Meter e Sweep Generator e Audio Generator e Modulation Analyzer e Signaling Simulator e RF Scan Counter e High Performance Spectrum Analyzer with Markers Optional in R2600 amp R2625 standard in R2670 e Cable Fault Locator e Tracking Generator e Programmable Test Set Ups The R2600 family has a solution for your radio communication testing needs R2600 For Conventional Radio and Base Station Service If you service conventional two way systems the value packed R2600 is the product for you Because of its unique design the R2600 allows you to perform numerous complex functions with the same piece of equipment This one box design is especially useful in remote sites or where use of multiple pieces of heavy equipment is impractical or impossible R2625 Economical Project 25 Solution The most cost effective Project 25 test solution on the marke
15. creens can be set up as a This feature makes testing easier and more efficient It also provides start up default condition or as a programmable test set up Dedicated quantitative RF measurements to ensure proper system performance ASTRO SECURENET and PROJECT 25 test screens are windowed margin with RF and Modulation control screens to simultaneously display test results along with their test conditions While in ASTRO mode standard diagnostic test screens can be easily accessed SECURENET Available only in R2670 Feature Benefits Voice Mode System Testing Voice mode system testing provides SECURENET compatible modulation This feature allows verification of the proper operation and system and demodulation with vocoding Generate and monitor modes compatibility using actual encryption algorithms support functional voice testing in the encrypted mode using either test keys stored in the R2670 or customer selected keys provided by a separate DX key loader The R2670 also emulates an AX BX or CX key loader which can be used to download test keys to a compatible radio Bit Error Rate BER Testing BER can be measured using the built in V 52 test pattern generator This testing provides an accurate quantitative measurement of This standard non encrypted pattern can be used to either modulate modulation quality and overall system performance Loop back the Generator or inject into a radio or system under test via the testing is
16. e Distortion BNC Input Impedance RF RECEIVER FREQUENCY Range Resolution Accuracy Spurious Response 1 kHz tone PRIVATE LINE DIGITAL PRIVATE LINE Single Tone DTMF Two Tone Paging 5 6 Tone Paging International Select V 20 Tone General Sequence Tone Remote Control External inputs from both a supplied microphone and BNC input 5 Hz to 20 kHz 1 dB Programmable to 7 95 v peak 100 ohms nominal Not to exceed 1 THD 600 ohms nominal 400 kHz to 1 GHz 50 Hz Refer to Accuracy of Master Oscillator 40 dB typical SPECIFICATIONS SENSITIVITY Above 10 MHz Narrowband FM Wideband FM AM RF Scan FM DEVIATION MEASUREMENT Demod Range Accuracy Frequency Response Demodulated Output Level AM MODULATION MEASUREMENTS Demodulation Range Accuracy Frequency Response Demodulated Output Level Output Impedance RF Receiver Cont 2 0 uV for 10 dB EIA SINAD 10 uV for 10 dB EIA SINAD 10 uV for 10 dB EIA SINAD Monitor mode 20 MHz to 1 GHz unit will scan and find signals greater than 30 dBm Up to 5 kHz in Narrowband Up to 75 kHz in Wideband 5 plus peak residual FM Selectable per the following Low Pass Filters 300 Hz 3 kHz 20 kHz High Pass Filters 5 Hz 300 Hz 3 kHz 0 8 V peak per 1 kHz peak Deviation in Narrowband and per 10 kHz Deviation in Wideband 0 to 100 5 for levels below 80 Selectable per the following Low Pass Filters 300 Hz 3 kHz 20 kHz
17. ens to simultaneously display test results along with their test conditions A single system configuration screen for Type I systems provides non volatile storage of up to ten fleet maps ain sens atean 7 f a ee IEEE o zs _ This feature makes testing easier and more efficient It also provides quantitative RF measurements to ensure proper system performance Project 25 Conventional Standard in R2625 optional in R2670 not available in R2600 Voice Mode System Testing This feature provides Project 25 compatible FDMA Digital C4FM modulation and demodulation with vocoding and embedded data testing Generate and monitor modes support actual functional voice testing Within the voice mode embedded data can be encoded and decoded for either subscriber or fixed site radio equipment Benefits This feature allows you to verify operation and system compatibility under actual operating conditions for increased confidence of proper sys tem performance Bit Error Rate BER Testing BER testing can be performed on radios that support BER test capability The R2670 R2625 in Project 25 mode can generate RF transmissions modulated with either a 1011Hz tone test pattern or a calibration test pattern generates 5 BER for UUT BER measurement The units will compute a BER when a 1011 Hz tone test pattern is received Project 25 Trunking Optional in R2625 and R2670 not available in R2600
18. for both C4FM and LSM modulated signals while veri fying receipt and transmit of the C4FM modulated 1011 Hz test pattern Bit Error Rate BER Testing BER testing can be performed on base stations and repeaters which support BER test capability The R2670 and R2625 in Project 25 trunking mode can monitor RF transmissions modulated with a 1011BER test pattern This testing provides an accurate quantitatrve measurement of modulation quality and system performance fe ASTRO Available only in R2670 Feature Benefits Voice Mode System Testing This feature provides ASTRO compatible FDMA Digital C4FM This feature allows you to verify operation and system compatibility modulation and demodulation with vocoding and embedded data under actual operating conditions for increased confidence of proper testing Generate and monitor modes support actual functional voice system performance testing Within the voice mode embedded data can be encoded and decoded for either subscriber or fixed site radio equipment Bit Error Rate BER Testing BER testing can be performed on radios that support BER test This testing provides an accurate quantitative measurement of capability The R2670 in ASTRO mode can generate or monitor RF modulation quality and overall system performance The Duplex transmissions modulated with a V 52 BER test pattern mode supports loop back testing Dedicated Test Screens Conveniently accessed dedicated test s
19. hich allows the operator to quickly visualize the performance under test The Software also generates a histogram distribution of the EVM metrics providing another form of visual analysis of the transmitter s performance over time The CM816 EVM option can be used with any R2625C model analyzer or R2670B equipped with the CM801 enhanced digital hardware module and CM813 Project 25 option Channel Logging The CM815 P25 Channel Logging option provides P25 Common Air Interface data This includes Data Unit type and a breakdown of the various message and value fields as defined by the P25 standard Logging data is described with meaningful names i e an ALGID of 0x80 will be shown as Un encrypted Additionally message timing is provided with each sent and received message especially important when working with P25 Trunking For a lower level analysis of radio R26xx Channel Logging File Edit Logging ulss E ellul Q Conventional ISP HDU 15 10 19 584 C0 NAC 293 DEFAULT DUID 0 Header Data Unit 2 34 56 78 90 AB CD EF 00 encrypted ALGID 81 D 1234 undefined Default Talk Group DES encryption algorithm KI A TGID 0001 S 15 10 19 694 CS Conventional ISP LDU 1 NAC 93 DEFAULT DUID 5 Logical Link Data Unit 1 LE 80 00 7A 70 DF4 68 a ss 00 00 lita pja 15 10 19 694 CA Co NAC 293 DE DUID A Log 15 10 19 694 C Co LSD 1234 567 1
20. le vocoder for both generator and receiver provides functional voice testing capability via internal speaker and microphone accessory Scope display of voice waveform can also be selected Link Control Field LCF Presentation Address PA Key ID Network ID Busy Bits A default configuration can be selected or a detailed special screen can be accessed for customized programming A dedicated screen may be selected to display and decode the same data as described in the encode section The unit can also buffer 30 frames of data on a first in first out basis with the capability to selectively recall any of the stored frames to the screen Free running unframed V 52 pseudo random non encrypted sequence compatible with ASTRO test mode Measurement range from 0 to 20 bit errors DVP XL DES XL DVI XL For each of these algorithms the unit can accept customer keys from Motorola external key loaders DX Compatible ASTRO single key software encryption is also supported A single side connector is provided for key loading ASTRO Voice Frames containing both VSELP vocoded voice and embedded signaling or an unframed V 52 pseudo random non encrypted sequence ASTRO Voice Frames containing both VSELP vocoded voice and embedded signaling or an unframed V 52 pseudo random non encrypted sequence An unframed V 52 pseudo random non encrypted sequence SECURENET Optional Feature Voice Testing Encryption Capabilit
21. nd a standard silence test pattern Either Project 25 Standard Voice Frames containing IMBE vocoded voice and embedded signaling or a standard 1011 Hz tone test pattern Registration Call Alert Dispatch Voice WACN ID System ID WUID or UID WGID or GID RFSS ID Site ID IDEN_UP Test measurement display Call sequence status indicator Frequency Bands Generate Deviation Selection 12 Base Station Tests BER Capability WACN ID System ID UID GID WUID WGID 800MHz 851 00625MHz 876 59375MHz with a 45Mhz offset Channel plan 1 700MHz 762 00625MHz 787 59375MHz with a 30MHz offset Channel plan 2 UHF VHF User defined channel plan The channel plan range is 1 thru 16 This can also be used to define non standard 700MHz channel plans 0 00kHz 5 00kHz Full duplex modulation of 1011 Hz test pattern with simultaneous C4FM LSM demodulation of voice Also includes an averaging wattmeter with selectable period 09 sec to 4 32 sec and an accuracy of 15 Input range is from 5 watts to 125 watts peak Free running unframed V 52 pseudo random non encrypted sequence Measurement range from 0 to 20 bit errors ASTRO Optional Feature Voice Testing EMBEDDED SIGNALING Encode Capability Encode Operator Entry Decoding Operation BER Capability Encryption Capability Generate Capability Monitor Capability Duplex Capability ASTRO compatib
22. ne paging Select V and up to 20 sequential tones Decoding displays include tone frequencies and time durations of the individual tones The unit can also encode tone remote signaling The signaling capability of the unit reaches a broader range of service applications with its decode capability This gives you a more flexible test instrument which aids in servicing paging equipment and specialized signaling encoders as well as mobile portable and other radio products The signaling simulator can perform a full system check out faster with more accuracy than ever before General Purpose amp Modulation Oscilloscope The oscilloscope has a 50 kHz bandwidth for audio waveform analysis The display can be triggered over the full screen range to a fixed reference level Triggering in both automatic and normal modes is provided for synchronizing the horizontal timebase to the vertical input signal Internal or external inputs allow observation of both generated and monitored modulation signals Softkeys provide for an enlarged full screen display Recovered audio or internally produced audio can be displayed visually for deviation measurements Additionally detection of an asymmetric modulation or audio distortion can be achieved with waveform analysis With internal and external triggering and a freeze display single sweep this unit duplicates many features of more expensive scopes The markers allow detailed analysis to measure waveforms di
23. res continued Feature Benefits Relative Signal Strength Meter In addition to reading frequency error and modulation a digital readout relative signal strength meter has been included Sensitivity is specified to 100 dBm at the antenna port for FM signals and extends up to 125 watts at the RF I O port The LCD display will automatically convert to a terminating watts display as the level increases This feature in conjunction with an external antenna allows remote monitoring of distant transmitters to check for antenna transmission line or P A problems Many users also find this feature convenient in performing propagation studies to identify weak coverage areas RF Scan RF Counter Function RF Scan operates in the monitor mode and provides a function similar to a 1 GHz counter This feature automatically scans a user defined frequency range and locks on the applied signal Any RF carrier above 20 MHz can be located within 5 seconds and the reception displayed with digital readouts This feature allows convenient and immediate verification of the programming of a multi channel radio By automatically tuning the analyzer s receiver to the detected carrier immediate measurement data can be taken without having to enter new frequency data via the keyboard Duplex Full output level control from 130 dBm to 0 dBm over the entire range of the instrument is available from the RF I O port 130 dBm up to 50 dBm and
24. s ground Includes RS232 and IEEE 488 2 Portable Power Pack for R2600 Series Analyzers STANDARD CAPACITY PART 201915 01 Number of Battery Packs One Voltage 12 VDC Battery Capacity 10 Amp Hour Weight 5 75 Ib Approximate Run Time gt 1 Hour Dimensions inches 6x8 5x6 HIGH CAPACITY PART 201915 02 Number of Battery Packs Two Voltage 12 VDC Battery Capacity 20 Amp Hour Weight 9 5 Ib Approximate Run Time gt 2 Hours Dimensions inches 6x8 5x6 NA Option Not Available Accessory Included with model 15 R2600 Series Communications System Analyzers Service maintenance and technical support For support on General Dynamics test equipment contact United States Motorola Test Equipment Service Center 2216 Galvin Drive Elgin IL 60123 Phone 800 323 6967 Canada Navair Inc 6375 Dixie Road Mississauga Ontario Canada LST2E7 Phone 800 668 7440 Europe the Middle East and Africa Motorola Test Equipment Service Center Heinrich Hertz Strasse 1 65232 Taunusstein Neuhof Phone 49 6128 700 Asia and the Pacific Rim excluding Japan Motorola Electronics Pte Ltd Motorola Innovation Centre CGISS 7th Floor 12 Ang Mo Kio Street 64 Ang Mo Kio Industrial Park 3 Singapore 569088 Phone 65 6486 3256 Fax 65 6486 3257 Japan Nextec Japan Ltd Nextec High Tech Center 10 8 Mitsuzawanakamachi Yokohama City Kanagawa Protecture Japan Phone 81 45 410 2287 Australia and New Zealand
25. splayed on the LCD The EXPAND function provides an enlarged easy to interpret view of the signal for quick analysis Flash Upgradable Software High Speed serial port and flashable memory permit programming firmware updates from an external PC Quick and easy access to future software updates Cable Fault standard in R2670 optional in R2600 and R2625 Cable fault and length are RF measurement features which help the technician isolate cable defects Supported by on screen prompts and user selectable Help messages you can quickly set up and accurately determine the distance to a fault on a coaxial cable The distance to fault or cable length is computed and displayed in feet or metric units Cable fault locating techniques are mandatory for site servicing where visual inspection is not practical safe or effective in detecting hidden or cold flow damage The semi automatic operation of the cable faultfinder precludes the use of mathematical formulas and manual calculations maximizing your on site productivity RS 232 Serial Interface standard IEEE 488 2 Interface optional A full bi directional RS232 port is standard and includes the capability to respond to serial input command vocabulary and return measurement results as a serial output stream Included are user selectable baud rates up to 115 2 Kbps and start stop and parity bit selection In addition this dual function port can drive a serial printer to print out da
26. supported while operating in Duplex mode baseband output This BER pattern can then be recovered from the radio system either through the analyzer s receiver or from its baseband input to perform a closed loop BER test The BER test is also available in the unit s Duplex mode Project 25 ASTRO and SECURENET Common Features Available only in R2670 Feature Benefits Encryption Test Option Voice and embedded data encode and decode testing can also be done This feature allows verification of the proper operation and system in the encrypted mode using either test keys which are permanently compatibility using actual encryption algorithms stored in the R2670 or actual customer selected keys which can be loaded into the unit using a compatible key loader Baseband Audio Scope Display This display provides a clear graphic image of the audio baseband This feature provides greater assurance of proper system operation signal selectable at either the vocoder input in generate mode or the through its graphic display of voice or tone modulation vocoder output in monitor mode OPERATING DISPLAY MODES Cable Fault Locator AM FM Generate Audio Synthesizer Spectrum Analyzer Duplex Generator Sweep Generator Tracking Generator Cable Fault Locator Frequency Counter Digital Voltmeter Wattmeter Oscilloscope Signal Strength Meter SINAD Distortion Meter Frequency Error RF SIGNAL GENERATOR FREQUENCY Range Resolution Acc
27. t the R2625 is specifically configured for the needs of those servicing Project 25 along with conventional two way analog systems In addition to all of the test capabilities of the R2600 the R2625 comes standard with DES OFB Project 25 compatible Type III encryption The R2625 also contains Project 25 diagnostic test capability and can be optionally expanded to include the following e Tracking Generator e Cable Fault Testing e Programmable Test Set Up Memory e Project 25 compatible Type IHI AES Encryption e Project 25 Trunking R2670 Expandable Platform for Digital Trunked and Secure Testing In addition to having all the capabilities found in the R2600 the R2670 FDMA digital Communications System Analyzer is a special digital hardware platform that allows customized configuration to include multiple test capabilities in one convenient package R2670 OPTIONAL test capabilities e SMARTNET SmartZone Type I I EP II II e Project 25 Standard Conventional IMBE and Encrypted e ASTRO Conventional VSELP and Encrypted e R2680 MPT1327 1343 Test Solution Advanced Project 25 Test and Diagnostics Error Vector Magnitude The CM 816 Error Vector Magnitude EVM application provides a constellation diagram that gives a clear visual picture of how close the measured signal aligns with an ideal reference It works with C4FM CQPSK and LSM modulation types and includes a user definable tolerance setting w
28. ta and graphic displays The optional IEEE remote interface option contains the necessary hardware and software for IEEE 488 2 If you have large volume repetitive testing requirements this feature allows you to write your own programs to reduce test time costs Printed results can be used as part of the service shop s internal quality control system and can be used to demonstrate performance to the radio equipment user SMARTNET SmartZone Available on R2670 only Dynamic Call Testing of Subscriber Radios This feature tests Motorola compatible Type I Type II SmartZone and ASTRO IMBE VSELP trunked mobile and portable radio units under actual signaling conditions This is achieved by simulating the function of the trunked fixed end equipment The radio access control channel is provided to perform initial registration A thermometer style graphic indicator shows call progression as it directs the radio to a traffic channel for parametric measurements and voice testing Radio initiated or system initiated tests can be performed in either the phone interconnect or dispatch call modes Dynamic Call Testing allows you to test auto affiliation for SMARTZONE systems An additional RF synthesizer provides simultaneous control and traffic channels operator selectable over the entire band of allowable channels This option also allows you to exit from the main testing screen while a call is in process to access the other diagnostic screens
29. the generator port 80 dBm to 0 dBm Variable offsets from 0 to 999 995 MHz in 2 5 kHz steps are keypad selectable The duplex generator provides enhanced capability to service equipment such as repeaters and full duplex radios Full RF level control as well as full internal and external modulation capability allows receiver desensitization and transmitter tests to be performed simultaneously through one port if desired The wide offset range extends the functionality to include cross band repeater systems as well as enhanced receiver and transmitter troubleshooting capabilities Tracking Generator standard in R2670 optional in R2600 and R2625 The combining of the capabilities of the sweep generator and the spectrum analyzer into a Tracking Generator function allows the user to view the performance characteristics of many RF filter devices Display range is operator selectable from a 200 kHz window up to a 50 MHz window anywhere in the 400 kHz to 1GHz spectrum Diagnosis and adjustment of critical receiver front ends IFs helical filters cavities combiners and duplexers can be made in a few minutes quickly and easily with the flexibility of a tracking generator at your fingertips Signaling Simulator Encoder and Decoder The System Analyzer includes the capability of encoding and decoding PRIVATE LINE PL DIGITAL PRIVATE LINE DPL and single tone sequences as well as multi tone sequences including DTMF signals 5 6 to
30. try Decoding Operation BER Capability Encryption Capability Generate Capability Monitor Capability Call Sequence Tests Project 25 Trunking Test Parameter Entries Project 25 compatible IMBE vocoder for both generator and receiver provides functional voice testing capability via internal speaker and microphone accessory Scope display of voice waveform can also be selected Link Control Field LCF Low Speed Data LSD Key ID Network ID Status Symbol A default configuration can be selected or a detailed special screen can be accessed for customized programming A dedicated screen may be selected to display and decode the same data as described in the encode section The unit can also buffer 30 frames of data on a first in first out basis with the capability to selectively recall any of the stored frames to the screen Compute BER from received non encrypted 1011 Hz tone test pattern Generate non encrypted 1011 Hz tone test pattern or a calibration test pattern generates 4 977 BER for UUT BER calculation with Project 25 test mode AES DES OFB DVP XL DES XL DVI XL For each of these algorithms the unit can accept customer keys from Motorola external key loaders DX compatible A single side connector is provided for key loading Project 25 Standard Voice Frames containing both IMBE vocoded voice and embedded signaling a standard 1011 Hz tone test pattern a calibration test pattern a
31. unter Range Input Level Accuracy 400 kHz to 1 GHz 60 dB Automatically selected 6 kHz 100 kHz per division amp below 30 kHz 200 kHz per division amp above 50 to 95 dBm Freeze Max Hold Peak Hold Average Delta or Absolute Level and Frequency 400 KHz to 1 GHz 4 dB gt 3 MHz 100 dBm antenna port rating 400 KHz to 1 GHz 1 watt to 125 watts 50 ohms with maximum VSWR of 1 5 1 10 gt 3 MHz Over temperature alarms 400 kHz to 1 GHz 0 to 80 dBm Standing Wave Analysis Fault distance cable length Feet and meters 10 6 4 in 17 cm diagonal 0 to 50 kHz Selectable from the following 10 mV to 10v per division 5 of full scale all ranges Selectable 20 usec to 1 sec per division Automatic normal and single sweep Delta Voltage Delta Frequency Delta Period RMS DC plus AC of 50 Hz to 20 kHz 1 0 V 10 0 V 100 0 V full scale 1 full scale 1 least significant digit 1 0 V 10 0 V 70 0 V full scale 5 full scale 1 least significant digit 5 Hz to 500 kHz plus Auto Tune 5 Hz to 20 kHz 0 1 v RMS minimum input level See TIME BASE SPECIFICATIONS Cont Metering amp Measurement Cont SINAD DISTORTION METER Input Level SINAD Accuracy Distortion Range Distortion Accuracy 0 1 V to 10 V RMS 1 dB at 12 dB SINAD 1 to 20 0 5 of distortion or 10 of reading whichever is greater C Message Filter CCITT Filter w 600 ohm switchable load Optional
32. uracy Stabilization Time OUTPUT Range FM Range AM Accuracy DUPLEX GENERATOR Range Receiver Resolution Output Frequency Offset Accuracy SPECTRAL PURITY Spurious Harmonics FM MODULATION Deviation Accuracy Residual FM Frequency Range AM MODULATION Range Resolution Residual AM Frequency Range PHASE MODULATION Range Accuracy Resolution Frequency Range 400 kHz to 1 GHz 50 Hz Refer to Accuracy of Master Oscillator 1 Second 130 dBm to 0 dBm 130 dBm to 3 dBm 2 dB 80 dBm to 130 dBm RF 1 0 Port 4 dB gt 3 MHz all other levels and ports aus 400 kHz to 1 GHz 50 Hz 130 dBm to 0 dBm 0 MHz to 999 995 MHz in 2 5 kHz steps Same as Signal Generator 35 dBc within 20 MHz of selected carrier frequency Additional fixed spurs at an absolute level of lt 90 dBm at harmonic frequencies of 5 MHz These can affect level and modulation measurements when operated at low levels at or very near these specific frequencies 20 dBc 99 5 kHz 5 of setting 25 Hz 1 kHz NB 5 of setting 250 Hz 1 kHz WB 20 Hz max 300 Hz to 3 kHz 5 Hz to 20 kHz 0 to 90 1 of modulation 1 0 max 300 to 3 kHz 100 Hz to 10 kHz Optional 0 5 to 10 radians 8 at 1 kHz 1 radians 01 below 2 00 radians 300 to 3000 Hz AUDIO MODULATION SYNTHESIZER Modulation Types Mod Output Amplitude Flatness Mod Output Level Mod Output Impedance 1 kHz Ton
33. y End of Message Test BER Capability SECURENET compatible vocoder for both generator and receiver provides functional voice testing capability via internal speaker and microphone accessory Scope display of voice waveform can also be selected DVP XL DES DES XL DVI XL For each of these algorithms the unit can emulate an AX BX or CX type key loader to load test keys to a compatible radio It can accept actual keys from Motorola external key loaders A single side connector is provided for key loading The signaling tone that terminates a SECURENET transmission can be detected and displayed to the operator Free running unframed V 52 pseudo random non encrypted sequence Measurement range from 0 to 20 bit errors METERING amp MEASUREMENT SPECTRUM ANALYZER Frequency Range Dynamic Range Bandwidth Display Range Modes Markers SIGNAL STRENGTH INDICATOR Range Accuracy Sensitivity WATTMETER RF 1 0 PORT Frequency Range Measurement Range Input Impedance Accuracy Protection TRACKING GENERATOR Frequency Range Tracking Display Display Range CABLE FAULT Method Measure Reading Accuracy OSCILLOSCOPE Display Size Frequency Response Vertical Input Ranges Accuracy Sweep Ranges Trigger Markers DIGITAL VOLTMETER Meter Type Frequency Range DC Voltage Ranges Accuracy AC Voltage Ranges Accuracy FREQUENCY COUNTER Frequency Range Period Co

Download Pdf Manuals

image

Related Search

Related Contents

BN Series Countertop Bain-marie  スマート 電子 EE スイッチ付フル接地防水コンセント  halsey taylor owners manual manual del propietario halsey taylor  Erste Schritte mit AWS  IAN 88055  Delta 138283 Installation Guide  Califone 916 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file