Home

How To Install Your Gas Dryer

image

Contents

1. IMPORTANT Read and save these instructions IMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical and gas inspector s use How To Install Your Gas Dryer This dryer is set to operate on Natural Gas Before you start make sure that you have the following e New metal exhaust duct Do Not use plastic duct If you are using an existing duct system remove any lint buildup see Panel B Exhaust requirements All the tools you will need and parts needed to connect gas supply to dryer see Panel A The proper gas supply see Panel A A grounded 120 volt 60 Hz AC only 15 or 20 ampere fused electrical circuit see Panel B Electrical requirements e Proper location see Panel A and back cover Way Part No 3395332 Rev B nN as Q Q O Q y cC Q ret _ nw 1 1q SDS Before you start Check location where dryer will be installed Proper installation Is your responsibility The dryer must not be installed or stored in an area where it will be exposed to water and or weather Make sure you have everything necessary for correct installation Proper gas and electric supply connections should be available 42 3 8 Protection from the weather ai Proper operation of dryer cycles requires temperatures
2. e Do Not touch any electrical switch Do Not use any phone in your building Clear the room building or area of all occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Never install dryer up against draperies or curtains or on carpet Keep any and all items from falling or collecting behind the dryer Installation and service must be performed by a qualified installer service agency or the gas supplier 4 WARNING Fire Hazard if you Install the dryer In a garage car port or areas near vehicles where fumes from gasoline or other flammable materials may be present the vapors may be heavier than alr and remain near floor Piace dryer a minimum of 18 Inches above floor Check with your bullding Inspector regarding requirements for this Installation Failure to follow these Instructions could result In fire or explosion D m Provide a rigid gas supply line to the dryer location When rigid pipe is used it should be 1 2 inch IPS When acceptable to the gas supplier and local codes 3 8 inch approved tubing may be used for lengths under 20 feet For lengths over 20 feet larger tubing should be used Pipe joint compounds resistant to the action of L P gas must be used shutoff valve open position to dryer rigid supply line E m The supply line shall be equipped with
3. above 45 F or the dryer may not shut off wnen automatic cycles are used Four inch metal exhaust duct is required Support The floor must be able to support dryer weight of 175 pounds Dryer Door Clearances Location must be large enough to fully open dryer door See back cover of Installation Instructions or label on dryer rear panel for recessed and closet requirements 16 1 4 Pe 13 3 4 Da Full Width Hamper Door Extra Large Hamper Door shown above Mobile Home Installation This appliance Is sultable for mobile home Installations The Installation of the dryer must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 For mobile home use this appliance MUST be fastened to the floor and MUST be exhausted to the outside Order Mobile Home Installation Kit No 346765 from your dealer Kit includes the necessary fastening hardware and detailed installation instructions Metal exhaust system hardware is also available through your dealer This installation must conform with American National Standard National Fuel Gas Code ANSI 2223 1 latest edition and all local codes and ordinances Tools and materials needed for installation metal exhaust duct A as suppiy connection for 4 f hi 8 male pipe thread a ae on y i Sed adjustable level Sy er wrenc
4. a shutoff valve This valve should be located in the same room as the dryer and should be ina location that allows the valve to be opened and closed easily Do not block access to shutoff valve F If the dryer is installed in a confined area such as a bedroom bathroom or closet provision must be made for enough air for combustion and ventilation Check governing codes and ordinances Also check recessed and closet installation instructions section or label on dryer rear panel for detailed instructions G E If local codes permit it is recommended that new flexible metal tubing design certified by the American Gas Association be used for connecting the appliance to the rigid gas supply line The gas pipe which extends through the lower rear of the appliance has 3 8 Inch male pipe thread red cap re E If rigid pipe is used as a gas supply line a combination of pipe fittings must be used to obtain an in line connection to the dryer I E Make sure that lower edges of the cabinet plus the back and bottom sldes of the dryer are free of obstructions to permit adequate clearance of air openings for combustion air See Recessed and closet Installation instructions on the back cover for minimum spacing requirements J E For ease of installation operating and servicing if ever needed adequate space should be provided around the dryer K A 1 8 inch NPT plugged tapping accessible for test gauge connectio
5. a diamond marking That s how far the leg is supposed to go into the hole Start to screw the legs into the holes by hand Use a wrench or 1 socket wrench to finish tuming the legs until you reach the diamond mark 4 CAUTION Floor Damage Slide dryer onto cardboard or hardboard before moving across floor Fallure to do so may cause damage fo floor covering 7 a Now stand the dryer up Slide dryer onto cardboard or hardboard Panel C 18 Numbers correspond to steps eS 8 m Move the dryer close to its final location but leave enough room to connect exhaust duct and gas supply Remove cardboard or hardboard To make sure the dryer is level take a carpenter s level and place it on the top of the dryer first side to side then front to back If the dryer is not level adjust the legs of the dryer up or down The dryer must be level to prevent noise and to provide good drying performance red cap 9 m Remove the red cap from the gas pipe Move the dryer Into its final position 1 O m Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for gas connections If flexible metal tubing Is used be certain there are no kinks shutoff valve open position to dryer rigid gas supply line 1 1 g Tum the shutoff valve in the gas supply line to the open position A WARNING Fire Hazard Do Not use an open flame to test for leaks from gas
6. connections Checking for leaks with a flame may result In a fire or explosion 1 2 E Use a brush and liquid detergent to test all external gas connections for leaks Bubbles around connections will indicate a leak If a leak appears shut off gas valve controls and tighten connections Then check connections again Rn N ait At 1 3 m Connect exhaust duct to exhaust hood and dryer See Exhaust requirements Panel B Use the straightest path possible to avoid 90 tums Use duct tape fo seal all joints in the exhaust system Use caulking compound to seal exterior wall opening around exhaust hood 1 4 Check that all legs are properly installed and that dryer Is level 1 5 m Check to make sure you have all the tools you started with see Panel A 1 6 Plug the power supply cord into the grounded Ee outlet 1 T mw Carefully slide dryer into its final location Check to be sure legs were properly installed and dryer is level 1 8 Read the Use and Care Guide to fully understand your new dryer Use a full heat cycle not the air cycle for at least five minutes to remove air from the gas supply line Open the dryer door You should feel heat inside the dryer If you do not feel heat shut off the dryer for five minutes Check that the gas supply line shutoff valve is in open position Repeat the five minute test timer contro knob To get the most efficient use f
7. This dryer is equipped for use with NATURAL GAS It is design certified by A G A for L P Propane or butane gases with appropriate conversion No attempt shall be made to convert the appliance from the gas specified on the serial rating plate for use with a different gas without consulting the serving gas supplier Conversion must be done by a qualified service techniclan Gas conversion kit part numbers are listed on the gas valve burner base Cc m The design of this dryer has been certified by the American Gas Association for use at altitudes up to 10 000 feet above sea level at the B T U rating indicated on the model serial plate Burner input adjustments are not required when the dryer is operated up to this elevation When installed above 10 000 feet a four percent 4 reduction of the burner B T U rating shown on the model serial plate is required for each 1 000 foot increase in elevation For assistance when converting to other gas types and or installing above 10 000 feet elevation contact your local service company and parts packages 4 WARNING Fire Hazard For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Do Not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do Not try to light any appliance
8. avoid sagging and kinking that may result in reduced air flow The exhaust outiet is located at the bottom rear of the dryer The exhaust duct can be routed up down left right or straight out of the back of the dryer General space requirements can be found in Recessed and closet installation instructions on the back cover Use the straightest path you can where possible to avoid 90 turns The maximum length of the exhaust system depends upon the type of duct used number of elbows and type of exhaust hood The maximum length for both rigid and flexible duct is shown in chart A 4 foie NUMBER OF EXHAUST HOOD TYPE 90 TURNS A B c LENGTH OF 4 DIA RIGID METAL DUCT MAXIMUM LENGTH OF 4 DIA FLEXIBLE METAL DUCT The maximum length using a 2 x 6 rectangular duct with 2 elbows and a 2 1 2 TYPE C exhaust hood is 8 ft For exhaust systems not covered by the exhaust length chart see Service Manual Part No 603197 available from your local parts distributor Service check The back pressure in any exhaust system used must not exceed 0 6 inches of water column measured with an inclined manometer at the point that the exhaust duct connects the dryer An exhaust hood should cap the exhaust duct to prevent exhausted air from returning into dryer The outlet of the hood must be at least 12 inches from the ground or anything else that may be in 12 min the pat
9. cessed front view Part No 3395332 Rev B 1994 Whirlpool Corporation Benton Harbor Michigan 49022 If dryer does not operate properly Before calling for service check to be sure that A Electrical supply is connected B The house fuse has not blown or circuit breaker has not tripped C Door is closed D Controls are set in a running or ON position E Start button has been pushed firmly F Gas supply line shutoff valve is open When moving the dryer Disconnect the power supply cord and tape securely to dryer e Shut off the gas supply valve controls in the gas supply line Disconnect gas pipe fittings from dryer and cap the gas supply line Tape the drum to the front panel Tape the dryer door lint screen lid and end of dryer gas pipe e Tum leveling legs all the way in Before installing your dryer in your new home check with your gas supplier or dealer to see that your dryer is equipped with the correct burner for the particular type of gas in your new home Bumer Information may be found on the rating plate in the door well of the dryer If you need assistance Check your Use and Care Guide for a toll free number to call or call the dealer from whom you purchased this appliance The dealer is listed in the Yellow Pages of your phone directory under Appliances Household Major Service and Repatr When you call you will need the dryer model number and seria
10. crewdriver between cabinet front and lower access panel 3 inches in from each side Push down on retainer clips and pull lower access panel forward The lower access panel is hinged at the gas lower bottom uron panel 3 Close lower access panel Gas shutoff valve open and closed position gas shutoff valve in closed or off position Optional shutoff valve gt gas shutoff valve in rear of dryer open or on position Panel B Electrical requirements WARNING Electrical Shock Hazard Electrical ground Is required on this appliance Do Not modify the power supply cord plug If It does not fit the outlet have a proper outlet Installed by a qualified electrician Do Not have a fuse In the neutral or grounding circuit A fuse In the neutral or grounding circuit could result In an electrical shock Do Not use an extension cord with this appilance e Check with a qualified electrician If you are In doubt as to whether the appliance Is properly grounded Fallure to follow these Instructions could result In serious Injury or death It codes permit and a separate grounding wire Is used It ls recommended that a qualified electrician determine that the grounding path Is adequate A 120 volt 60 Hz AC only 15 or 20 ampere fused electrical supply is required Time delay fuse or cir
11. cuit breaker is recommended It is recommended that a separate circuit serving only this appliance be provided Recommended grounding method For your personal safety this appliance must be grounded This appliance is equipped with a power supply cord having a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged Into a mating 3 prong grounding type wall receptacle grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly 3 prong grounding grounded type wall receptacle 3 prong wali 3 pron receptacle grounding installed bya Plug qualified electrician N grounding prong power supply cord Exhaust requirements 4 WARNING Fire Health Hazard Do Not use non metal flexible duct Do Not use metal duct smaller than four Inches In diameter e Do Not Use exhaust hoods with magnetic latches e Check that exhaust system Is not longer than specified Exhaust systems longer than specified will Accumulate lint Shorten the life of the dryer Reduce performance resulting In longer drying times and Increased energy usage Fallure to follow specifications may result In a flre Do Not exhaust dryer Into a chimney furnace cold alr duct attic or crawl s
12. h TSS flat blade utility N screwdriver knife N pipe wrench 1 socket wrench duct tape Gas supply requirements OBSERVE ALL GOVERNING CODES AND ORDINANCES 4 WARNING Firo Hazard This dryer must be connected to a regulated gas supply Failure to do so could cause high pressure gas release resulting In a fire or explosion Have the L P gas checked by a qualifled person before Installing the dryer The L P gas supply must not exceed a pressure of 13 water column New flexible tubing should be used Reusing old flexible tubing might result In possible leaks or fire hazard Fallure to follow these instructions may result In fire or explosion Panel A Important Observe all governing codes and ordinances Check code requirements Some codes limit or do not permit installation of clothes dryers In garages closets mobile homes or sleeping quarters Contact your local building inspector Open dryer and remove literature gas burner inlet pipe connection at rear of dryer Level floor 1 inch maximum floor slope under entire dryer 14 1 4 ia cable Mini Hamper Side Swing Door Door A Check that dryer Is equipped with the correct bumer for the particular type of gas in the home Bumer information will be found on the serial rating plate In door well of the appliance If this information does not agree with the type of gas avallable see your dealer B m
13. h of the exhaust 4 Inch outlet hood Is preferred However a 2 1 2 inch outlet may be used with short systems only A 2 1 2 inch outlet can result in longer drying times than other hood types For permanent Installation a stationary exhaust system Is required For mobile home Installation the dryer must have an outside exhaust if you exhaust the dryer through the floor and the area under your mobile home is enclosed the exhaust system must terminate outside the enclosed area Extension beyond the enclosure will prevent lint and moisture buildup under the mobile home Now start With dryer in laundry area 1 m If your dryer has tape at front corners remove tape 2 m Open dryer and remove the literature and parts packages If your dryer has tape on the door remove tape open door and remove the rast of the tape from dryer drum Remove drying rack if your dryer has one Remove all parts from the plastic packages Make sure you have four leveling legs le 3 If your dryer drum was taped move drum counterclockwise to make sure all tape was removed Wipe the interior of the drum thoroughly with a damp cloth to remove any dust before using the dryer 4 m Take two of the comer pleces from the carton and place them on the floor In back of the dryer 5 m Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners 6 m With one of the legs in hand check the ridges for
14. l number Both numbers are on the serial rating plate located in the door well behind dryer door and on front of opening Printed on recycled paper 10 post consumer waste 50 recovered materials Printed in U S A
15. n must be installed immediately upstream of the gas supply connection to the dryer The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system L m If service is required determine the type of front panel your dryer has and follow those instructions 4 WARNING Electrical Shock Hazard Disconnect from electrical supply before removing access panel Do not operate dryer without access panei securely In place Fallure to follow these instructions could result In electrical shock or death One piece front panel wiring diagram location The dryer gas shutoff valve is located behind the one piece front panel The wiring diagram is located inside the console These Items should be accessed only by a qualified service technician gas shutoff valve one piece front panel 1 Disconnect electrical supply 1 2 Remove lint screen and set aside 3 Remove two screws from lint screen area 4 Grasp front cabinet top corners and pull forward and up top is hinged at rear 5 Remove two screws from front panel flanges Lift front panel off lower clips 6 Remove door switch wires if necessary and set front panel aside 7 Reassemble in reverse order Note The door switch wires must not touch the drum Lower access panel wiring diagram location 1 Disconnect electrical supply 2 Insert flat blade s
16. pace or any other duct used for venting e Clean the exhaust system every other year e Do Not install flexible duct In enclosed walls cellings or floors Accumulated iint could be fuel for a fire or cause molsture damage Exhaust the dryer outside to prevent exposure to substances In the gas fuels and combustion which may be harmful to your health The molsture and lint Indoors may cause Lint to gather Inside and around the dryer and be a fuel for fire Molsture damage to woodwork furniture palnt wallpaper carpet etc Housecleaning problems and possible health problems Fallure to follow these instructions could result In fire damage property damage personal Injury or health problems If using existing exhaust system clean lint from entire longth of exhaust system Make sure exhaust hood Is not plugged with lint Replace plastic exhaust duct with rigid metal or flexible metal duct Use duct tape to seal all joints Four Inch rigid metal Dener pipe is preferred Plan installation to use the good fewest number of elbows and turns Metal flexible duct should be fully extended and supported when the dryer is in final position DO NOT KINK OR CRUSH THE DUCT The metal flexible duct must be completely open to allow adequate exhaust alr to flow Allow as much room as possible when using elbows or making runs Bend duct gradually to avoid kinking Remove excess flexible duct to
17. rom your new dryer read your Use and Care Guide Keep Installation Instructions and Guide close to dryer for easy reference Recessed and closet installation instructions TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE FROM ACCUMULATING TO MAINTAIN DRYING EFFICIENCY AND TO PREVENT EXPOSURE TO POSSIBLE HEALTH HAZARDS THIS MACHINE A WARNING Flre Health Hazard Exhaust the dryer to the outside to prevent MUST BE PINAUSTED OU DOO exposure to substances In the gas fuels cone appliance spacings should be and combustion by products which may be harmful to your health e If dryer is Installed In a closet the dryer MUST be exhausted outside Failure to do so may result in a fire or health hazard Detailed space requirements can be found on the label located on the back panel of dryer NOTE No other fuel burning appliance may be Installed In the same closet The following installation spacings and door air openings for the dryer are possible when installed and exhausted as noted Spacing as indicated is in inches and is minimum allowable For ease of installation and service additional spacing should be considered Closet door Closet installation o side view Additional clearances for wall door and floor moldings may be required Opening is minimum for closet door Louvered door with fed equivalent air openings is acceptable Additional space is needed when external exhaust elbow is used Re

Download Pdf Manuals

image

Related Search

Related Contents

Samsung Galaxy S3 Наръчник за потребителя  CARGA 166 - SR110103 - DIVISÃO 1 LIGHT  DV11G/DV11J  じゃがいも 中ー 個20。g程度 トッピング (適宜お好みにて) 粉砂糖  "user manual"  HandPunch® GT-400  Frigidaire FRS12PYS1 Product Specifications Sheet  Samsung 삼성 선풍기  Nuovo Progetto italiano 1 IWB Software USER`S MANUAL  Hewlett Packard Enterprise Ultrium 800 GB  