1. dial is turning Dead clock motor Clock motor gears do not rotate Filter Pump will not start when temp is below 32 F Wrong voltage cycle Loose clock motor connections Loose tripper Bent dial Defective motor Welded contacts Two ON trippers on dial No OFF tripper on dial Defective mechanism Defective clock motor open coil due to lightning or surge Loose clock motor connections Wrong voltage Defective thermostat Defective relay Faulty wiring Power outage Change clock motor Check connections Check change tripper Check change mechanism Change clock motor Change mechanism Change tripper Change tripper Change mechanism Change clock motor Check connections Change clock motor Replace thermostat Replace relay Check wiring Install stand by power Filter Control Cleaner Control WIRING Time Switc Time Switch DIAGRAM m NOTE Ground connections are not shown and vary with installation Team Block l ll To Filter To 240 V To Cleaner Relay Pump Breaker Pump gr wall ty Equipment Ground mme O00000000000 5 WARRANTY WIRED PUMPS If within one 1 year from the date of installation this product fails due to a defect in material or workmanship Intermatic 3 Incorporated will repair or replace it free of charge ALTERNATE WIRING FOR TWO INDEPENDENTLY The warranty does not cover labor for removal or reinstallation gt and
2. Booster Pump The trippers of this Time Switch should be set so that the operation of the Cleaner Pump falls within the operation of the a Filter Pump To avoid equipment damage the two Time Switches are interlocked and the Cleaner Pump would not operate unless the Filter Pump is already operating THE FREEZE PROTECTION THERMOSTAT is located in the lower left side of the enclosure and turns ON the Filter Pump when the air temperature where the Control Panel is located drops below the temperature set by the dial between 32 F and 45 F IMPORTANT SAFETY INSTRUCTIONS When installing and operating this electrical control and other associated equipment basic safety precautions should always be followed including the following Read and follow all instructions This Control must be installed by a qualified electrician according to National and Local Electrical Codes Install this Control not less than 5 feet of inside edge of pool USE COPPER CONDUCTORS ONLY Do not exceed the maximum ratings of individual components wiring devices and current carrying capacity of conductors For grounding and bonding this Control and the installation refer to section 680 of the National Electrical Code The Control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly INSTALLATION 1 Select the proper location for the Control Panel and prepare the necessary co
3. 3 O Q D 12 850 Figure 1 OPERATION TO SET FILTER TIME SWITCH follow instructions on the right The length of the daily filtration neating cycle depends on many variables such as size shape and geographic location of the pool water chemistry type of pool equipment usage and season of year If not sure contact your local pool service professional for advice TO SET CLEANER TIME SWITCH follow instructions on the right NOTE This Control is factory wired to prevent equipment damage by allowing the Cleaner Pump to operate only when the Filter Pump is already operating This requires that the Cleaner Time Switch settings ON and OFF times must be within the operating hours of the Filter Pump For example If the Filter Pump is set to operate from 8 am to 2 pm daily the Cleaner Pump Time Switch should be set to operate no longer than 8 30 am to 1 30 pm TO SET THERMOSTAT turn dial pointing to desired temperature marked on the plate between 32 F and 45 F Again many variables must be considered before selecting the turn ON temperature of the Filter Pump and your local pool service professional is the best source
4. does not apply to a damage caused by accident abuse amp mishandling or dropping b a unit which has been subject to unauthorized repair c units not used in accordance with lt 3 directions d damages exceeding the cost of the product Some states do not allow a limitation of damages so the 3 foregoing warranty may not apply to you This warranty gives 3 you specific legal rights and you may also have other rights which vary from state to state This warranty service is available if the defective product or ss its defective component is returned with proof of purchase and date of installation either a to the dealer from whom the unit was purchased or b by shipping prepaid to Intermatic 3 Incorporated Intermatic Plaza Spring Grove Il 60081 9698 A amp FA ONEI ENTE OORO ONTE OTETI ENTE EEEE AE AE ETETE ISEE Se CLINI INICIO INOS NIN INI INI NIN INI DIINO INI NIN INCISIONS NIN IN INI N INI NIN IN IDI NIN IOS Because of our commitment to continuing research and improvements Intermatic Incorporated reserves the right to make changes without notice in the specifications and material contained herein and shall not be responsible for any damages direct or consequential caused by reliance on the material presented INTERMATIC INCORPORATED SPRING GROVE IL 60081 9698 158PF12441 4
5. ch and Cleaner Pump leads to terminals 2 and 4 of Cleaner Pump leads to terminals 2 and 4 of Cleaner Pump Time Switch Connect the grounding leads of each pump to the Equipment Grounding Terminal at the bottom of the enclosure If the Control Panel is installed in location where it is exposed to direct sun most of the day extend 8 inches of the copper capillary tube of the thermostat into an open ended plastic or metal conduit about 10 inches long installed at bottom of the enclosure Handle least 18 AWG wiring with insulation rated 300 Volt or higher Place heater ON OFF switch on heater to ON see Figure 2 Some heaters may require a special connecting harness contact heater manufacturer for details additional wiring devices inside the enclosure first remove rectangular knock out s in dead front Next remove hex head screws in back of a Turn the thermostat dial to its lowest setting and place crushed ice in plastic bag inside capillary coil of Thermostat b Turn ON power to Control Panel wait 20 seconds then slowly turn thermostat dial counter clockwise until Filter Pump starts Using the manual lever on Cleaner Time Switch turn ON OFF the Cleaner Pump Turn OFF power to Control Panel remove ice check wiring tighten terminal screws if necessary reinstall time switch insulators and front plate Turn ON power to Control Panel and set time Switches and the Thermostat see OPERATION instructions on page
6. nduit run s required by the installation layout Remove the four 10 hex head screws from the back of enclosure and install stand offs in place of screws Attach wiring device to stand offs Stand offs are not furnished Order 21T156A for a set of four 4 stand offs and mounting hardware 10 If external bonding is required install bonding lug s on oe SAGE MACH MOUDURY GrACKelS 1G bottom of enclosure 156T11047A may be ordered and bond installation according to code requirements 3 Hang enclosure on a flat vertical surface or other support using hardware suitable for the purpose 11 TEST INSTALLATION capillary tube with care m 8 If required by the heater manufacturer install fireman l r O switch kit 156T4042A not furnished on Time Switch eee Plate and make the fireman switch connections Use at E See a Properly terminate conduits To install PRESSURE PLATE Y at both ends and pull in the iS TERMINAL SCREW conductors as specified by gH MAKE SURE INSULATION the installation layout L CL EARS PRESSURE PLATE Follow wiring diagram on page 4 of this Manual connect LINE1 and LINE 2 OF THE 240 Volt supply conductors from a 20 Amp circuit breaker either in the main panel or in this subpanel to TB1 terminal block see insert above for proper connection and the grounding conductor to the Equipment Grounding Terminal Connect Filter Pump leads to terminals 2 and 4 of Filter Pump Time Swit
7. of information The Thermostat is factory set to turn OFF the Filter Pump when the ambient temperature rises 5 F above its set point THE FIREMAN SWITCH Heater Protection Mechanism if installed is factory set and shuts OFF the heater 20 minutes before the Time Switch turns OFF the filter pump The Fireman Switch requires no setting or service TIME SWITCH OPERATING INSTRUCTIONS 1 TO SET ON AND OFF TIMES Hold TRIPPERS against edge of CLOCK DIAL pointing to time AM or we PM when ON and OFF operations Ag are desired Tighten tripper screws 2 TO SET TIME OF DAY Pull CLOCK DIAL outward Turn in either direction and align the exact time of day on the CLOCK DIAL the time now when switch is being put into operation to the POINTER DO NOT MOVE POINTER TO OPERATE SWITCH MANUALLY Move MANUAL LEVER below CLOCK DIAL left or right as indicated by arrows This will not affect next operation FOR MORE THAN ONE DAILY ON OFF OPERATION Place additional tripper pairs on CLOCK DIAL order 1561T1978A IN CASE OF POWER FAILURE reset CLOCK DIAL to proper time of day See step 2 above ow ON 7 TRIPPER HEATER WARNING Do not disconnect high limit or pressure switches Figure 2 TROUBLESHOOTING SYMPTOM CAUSE S 1 Time Switch will not keep Frequent power outages CORRECTIVE ACTION Reset dial time dial is turning Time Switch Dial stops at ON or OFF tripper Load is ON at all times
8. pi FREEZE SENTRY INSTALLATION il y NTERMATIC By YNTeERMarTic OPERATION amp FREEZE PROTECTION FOR POOLS AND SPAS SERVICE MANUAL MODEL PF1202T TWO CIRCUIT POOL EQUIPMENT CONTROL WITH FREEZE PROTECTION IN RAINPROOF ENCLOSURE ELECTRICAL RATING 3 HP MAX 240 VOLT 60 HZ SUITABLE FOR POOL SPA EQUIPMENT CONTROL DANGER To Reduce the Risk of Injury do not permit children to operate the Control Unit or use the Pool Spa unless they are closely supervised at all times test GROUND FAULT protection regularly If it fails to reset DO NOT USE THE POOL or SPA Contact a qualified service technician always disconnect electricity before servicing this control or the equipment s connected to it THIS CONTROL IS NOT TO BE USED AS A POWER DISCONNECT READ FOLLOW amp SAVE THIS INSTRUCTION MANUAL GENERAL INFORMATION This Pool Equipment Control is designed to automatically operate the Filter Pump Cleaner Pump and also to provide freeze protection for the pool equipment Nevertheless this product is not intended to be a substitute for insulation coverings or maintenance THE FILTER PUMP TIME SWITCH is located in the upper left side of the enclosure and operates the Filter Pump as set by the trippers on the yellow dial on a 24 hour schedule For setting the schedule refer to page 3 of this Manual THE CLEANER PUMP TIME SWITCH is located in the upper right side of the enclosure and operates the Cleaner Pump