Model E1065 Indicator User`s Manual - Avery Weigh
Contents
1. Software mV Display Button port 4 Port 2 version test test and revision Pass Fail Pass Fail Figure 8 User Menu 1 Access the User menu by pressing and holding the ZERO key for 3 5 seconds PASS_ is displayed cancel 2 Key in the User menu password 111 and press F1 B FAH O TEST is displayed ESCAPE J ENTER 3 Press the PRINT key Choose the first digit using ABOUT is displayed Press the PRINT key then the UNITS key to the UP or DOWN keys Use view the part number and revision level for the software found in the LEFT and RIGHT keys to your indicator advance or backspace through the entry Press SELECT key to return to ABOUT 4 Press the UNITS key ADC is displayed This is the mV V output of the connected analog scale 5 Press the PRINT key The mV V value is displayed This value should increase as weight is applied to the scale Model E1065 Indicator User s Manual 25 10 11 12 13 14 15 16 17 18 19 26 Press the SELECT key ADC is displayed Press the UNITS key DISP is displayed This is the display test item Press the PRINT key to perform a dynamic test of the display All parts of the display flash Press the ZERO key to stop the test The display flashes a couple more times and then DISP is shown Press the UNITS key BUTTON is displayed This is the button test item Press the PRINT key to perform a button
2. gross weight display 1st press Net annunciator lights and net weight is displayed 2nd press Tare annunciator lights and tare weight is displayed 3rd press Display toggles between HI and the upper weight tolerance in the current unit of measure This will always be one division 4th press Display toggles between LO and the lower weight tolerance in the current unit of measure This will always be one division 5th press Display returns to gross weighing mode Model E1065 Indicator User s Manual Performing a Checkweighment in Sample Mode Using Cutoffs in Check weigher Application Standard Cutoffs Choose the first digit using the UP or DOWN keys Use the LEFT and RIGHT keys to advance or backspace through the entry B FAO he Ges CG3 u Wis z5 il ESCAPE ENTER Target Cutoffs 1 2 With your target weight set as described above place your item on the scale If the weight is correct 0 is displayed and the TARGET annuncia tor lights If the weight varies from the target value upper or lower segments may be lit and the weight will show a plus or minus weight reading for the deviation from the target weight Repeat step 1 for all products of this weight If enabled you can use the cutoff trips function while in the checkweigher application Cutoffs are enabled in a password protected menu See the Ser vice Manual for instructions Follow these steps to set up to three outputs 1 Nolo A
3. tings on the indicator and PLC Status and reboot the indicator Accumulator Lights when an accumulation occurs and while in the Green The network connec Count count and peak applications tion has been established i Custom Unit Lights when a custom unit of measure is active Amber The network is ready for a connection but no con KG Lights when kilograms is the active unit of measure nection has been established LB Lights when pounds is the active unit of measure Checkweigher Lights when checkweighing application is active Model E1065 Indicator User s Manual 7 Numeric Entry Procedure Press the ZERO key to termi nate a value entry and leave the previous value if any active Some keys have alternate functions when you need to enter numbers See Figure 4 n 0 E n I ZERO PRINT UNITS 3 ESCAPE gt ENTER Figure 4 Alternate key functions In screens where numeric entry is possible choose the first digit using the UP or DOWN keys Use the LEFT and RIGHT keys to advance or back space through the entry Press the F1 key to accept an entry Below is an example Example To key in the number 507 Repeatedly press the UP SELECT or DOWN PRINT key until 5 appears on the display Press the RIGHT UNITS key once to move cursor one space to the right Repeatedly press the UP SELECT or DOWN PRINT key until 0 appears on the display Press the RIGHT UNITS key once to move cursor one space to the
4. Information about displaying this information 20 Model E1065 Indicator User s Manual Dribble Sampling Choose the first digit using the UP or DOWN keys Use the LEFT and RIGHT keys to advance or backspace through the entry amp FO TARE SELECT ZERO PRINT UNITS ESCAPE J ENTER i Displaying Count Information 3 In gross weight mode press the F1 key A numeric value is displayed This is the current sample size Accept the current sample size by pressing F1 OR Enter a new sample size see note at left and press F1 Zeroin is briefly displayed This shows the indicator is zeroing itself Add is then displayed Place the correct sample size on the scale and press the F1 key Busy is briefly displayed followed by one of two possible outcomes a Ifthe sample met the minimum sample requirements and stable the display will show the correct number of parts on the scale and the green annunciator is lit b Ifthe sample size was not large enough or the weight was unstable Abort is displayed and the display returns to gross weight mode Repeat steps 1 3 using a larger sample size Place the parts on the scale to be counted You can accumulate the counts and track the number of transactions by pressing the PRINT key while in count mode See Displaying Count Information below about displaying this information If the piece weight of the item being counted is known you can manually enter the pi
5. With the indicator powered up in normal checkweighing mode press and hold the F1 key until OP7 is displayed Press the PRINT key The current value for OP1 is displayed Press F1 to accept this value OR Key in a value and press the F1 key OP7 is displayed Scroll through all three outputs by using the left and right arrow keys Repeat steps 2 and 3 for each output Press ESC key to exit the cutoffs setup As you apply weight to the scale output one will activate below its set point and deactivate above its setpoint The same is true for the other two setpoints Each output s annunciator will light on the display when the cutoff trip value is reached If cutoffs are configured for Target mode in the Supervisor menu cutoffs will follow the limits and accept values This means there is no additional con figuration required Model E1065 Indicator User s Manual 19 This section applies if your indicator has the counting application active Counting Applications are activated through a password protected menu See the Service Manual for instructions There are two types of sampling bulk and dribble These are selected in a password protected menu See the Service Manual for instructions Bulk sampling In this sampling method you place the specified number of items on the scale all at once in bulk and the scale automatically starts to calculate piece weight and then shows the count Dribble sampling I
6. and ESD protection Options e Analog output Pulse input e Remote I O e ControlNet e TIU3 e Rack mount kit Desk stand kit Operating applications e General weighing with accumulation Batching Counting Checkweighing Peak measurement Remote display Operating temperature e 14 to 104 F 10 to 40 C e 40 to 140 F 40 to 60 C non legal e Up to 95 non condensing humidity Enclosure e Composite IP 54 when panel mounted Dimensions e 10 5 W x 8 H x 7 75 D without mounting bracket e 10 5 W x 11 H x 8 25 D with mounting bracket Weight e 4 5 lb 2 kg Agencies e NTEP CC 04 031 Class III IIIL 10 000 divisions e OIML Cert R76 1992 GBI 04 10 Class III 10 000 divisions e Canadian Weights and Measures pending e UL CUL e CSA e CE marked om MIN fan f E et ON RSN T 4 Model E1065 Indicator User s Manual Introduction About This Manual Unpacking and Setup Attention Always plug the Model E1065 into an easily accessible grounded outlet of the appropri ate voltage Never use the unit without an appropriate earth ground connection Any computer based sys tem should have a separate grounded power circuit We recommend one for the Model E1065 The Model E 1065 is an easy to use uncomplicated indicator for weighing with the built in capability to provide network controls and share data via Eth erNet PROFIBUS and DeviceNet It is ideal for tank weighing applications prov
7. 1 is displayed 2 Press the PRINT key to change the amount of ingredient 1 to batch A numerical value is displayed 3 Scroll in a new value and press F1 or press F1 to accept the value that is shown The UNITS and TARE keys allow you to access all 8 ingredi ents 4 When finished press the ZERO key to escape from this menu Save will be displayed 5 To save the changes you made press F1 To exit without saving press the ZERO key The batch type batch mode and ingredient basis cannot be changed through this shortcut See the Service Manual for instructions on creating a recipe Model E1065 Indicator User s Manual Auto Batching by Weight Each ingredient may have a built in delay time between deactivation of one ingredient and activation of the next Following is an example of batching for a recipe set as follows Batch type Constant Batch mode Automatic Basis Weight With the indicator powered up and the scale empty zero the scale by pressing the ZERO key 0 is displayed Press the F1 key The OP1 annunciator lights and output 1 is activated Add weight to the scale When the weight reaches the setpoint for ingredient 1 OP1 an nunciator light goes out OP2 annunciator lights and output 2 activates See note at left Add weight to the scale When the weight reaches the setpoint for ingredient 2 OP2 an nunciator light goes out OP3 annunciator lights and output 3 activates See note
8. at left Add weight to the scale When the weight reaches the setpoint for ingredient 3 OP3 an nunciator light goes out and output 3 deactivates Empty the scale and repeat steps 1 5 for the next batch Model E1065 Indicator User s Manual 15 Manual Batching by Percentage Choose the first digit using the UP or DOWN keys Use the LEFT and RIGHT keys to advance or backspace through the entry eacouno GS Ges C3 Gi CS lt lt ESCAPE J ms ENTER 16 Following is an example of batching for a recipe set as follows gt Batch type Percentage Batch mode Manual Basis Weight With the indicator powered up and the scale empty zero the scale by pressing the ZERO key 0 is displayed Press the F1 key The OP1 annunciator lights and output 1 is activated Press the F1 key to accept the batch size OR Key in a new batch size see note at left and press the F1 key The OP1 annunciator lights and output 1 is activated Add weight to the scale When the weight reaches the percentage of the batch size set in the recipe for ingredient 1 OP1 annunciator light goes out Wait for the delay to elapse and then press the F1 key OP2 annunciator lights and output 2 activates Add weight to the scale When the weight reaches the percentage of the batch size set in the recipe for ingredient 2 OP2 annunciator light goes out Press the F1 key OP3 annunciator lights and output 3 acti
9. Avery Weigh Tronix P TT Model E1065 Indicator man User s Manual UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CANADA This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique que edict par le minist re de2s Communications du Canada EUROPEAN COUNTRIES WARNING This is a Class A product In a domestic environment this product may cause radio interference in which the user may be required to take adequate measures Caution Risk of electrical shock
10. Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS ATTENTION IL Y A DANGER D EXPLOSION S IL Y A REMPLACEMENT INCORRECT DE LA BATTERIE REMPLACER UNIQUEMENT AVEC UNE BATTERIE DU MEME TYPE OU D UN TYPE EQUIVALENT RECOMMANDE PAR LE CONSTRUCTEUR METTRE AU REBUT LES BATTERIES USAGEES CONFORMEMENT AUX INSTRUCTIONS DU FABRICANT CAUTION THE EQUIPMENT IS INTENDED ONLY FOR INSTALLATION IN A RESTRICTED ACCESS LOCATION Avery Weigh Tronix reserves the right to change specifications at any time 07 19 06 E1065_U P65 PN 43033 0019C e1 Table of Contents SPEdlcdli ocio ai 4 INFORUCHOMN cai iii 5 About tnis Maniliiae ea 5 Unpacking and Setup siicccsscesecssnasecssrcasacesansandnses sadszsaasnadsnneanatace iii 5 Front Pane lasien e eran 6 oe 6 ANNUNCIO iaia iaia 7 Numeri Entry PVCS CAN eater 8 MENU ModE csser E EE E EE AEE EEE 9 Indicator Operations sssrin R E EEEE 10 Gross WeighiN gesais a E a SMMC eee ae 10 TMS INGE Weighiihg sescca ienicerii OE 10 Acummulator WEeIghing iii iz 11 Using Cutoffs in the Accumulator Application nenene 12 BaleMRWVBIGRINGrcicr i ariani ira 13 Auto Batching pYWelighk osrsna n idee 14 Manual Batching by
11. E1065 Indicator User s Manual The accumulator is memory that collects individual weighments gross and Accummulator net and stores the totals These totals can be recalled at any time The Weighing number of weighments included in the totals can be displayed and all infor TE mation can be reviewed and deleted The Accumulator application To use the accumulator power up the unit and follow these steps comes as the default active ap plication in the E1065 1 Empty the scale and press ZERO key to zero the display 0 is displayed 2 Place item on the scale Weight is displayed You can use tare net weighing with the accumulator applica tion The accumulator stores both gross and net totals for A circle annunciator lights briefly on the right side of the display to later recall show the weight was accumulated 3 Press the F1 or PRINT key to add weight to the accumulator Pressing the PRINT key also prints the default print format 4 Remove weight from the scale Weight must return to zero before an other accumulation can be recorded 5 Repeat 2 through 4 for each weighment you want to accumulate 6 To review the accumulator total and the number of weighments remove all weight from the scale and press the SELECT key repeatedly You must remove all weight from the scale to scroll through ist press Net weight displayed the items listed at right With iii Tare weight displayed weight on the scale rep
12. Percentage n 16 Chechecighiind salealena aa 17 Limits Mode Entering Upper and Lower Limits 18 Sample Mode Using Product to Set Target Weight 18 Performing a Checkweighment trenne 18 Using Cutoffs in Checkweigher Application n 19 COLMI iaia 20 B lk Sampling PR eee EI AIA 20 Dribble SAM Ng ciccia 21 Displaying Count Infoimialioli ana 21 Using Cutoffs in the Counting Application 22 Peak Weighihig serirriceirer ieoi enra E E OE E 23 Using CUIO S airina a a arie 23 COMPING AION Sa ii 24 Error NS Ay sla 24 Indicator DIAGNOSUCS riali 25 Testing Indicator FUNGHONS sssini anea aE 25 IMPORTANT SISLISISLISLILIA This equipment must be routinely checked for proper operation and calibration I Application and usage will determine the frequency of calibration required for safe operation AS ISISISIIEAILA Model E1065 Indicator User s Manual 3 Specifications Power requirements e 85 265 Volts AC 0 3Amp maximum e 50 60 Hz Excitation e 5 volts DC e Supports up to eight 350 ohm weight sensors Analog signal input range e 60 mV Analog signal sensitivity e 0 2 pV V divisions minimum e 1 0 pV V divisions recommended Calibration 2 to 5 points stored Operational keys e Seven keys Tare Select Zero Print Units F1 On Off Operational annunciators e Center of Zero Motion Gross Net Tar
13. anual 9 Indicator Operations Gross Weighing To change unit of measure press the UNITS key Tare Net Weighing To clear a tare weight remove all weight from the scale and press the TARE key 10 The E1065 comes equipped with several weighing applications e Accumulator weighing default setting e Batch weighing e Checkweighing e Counting e Peak weighing These different applications are activated using a password protected Service menu See the Service Manual for instructions on changing applica tions The accumulator application comes as the default application You can do gross weighments tare net weighments and accumulator functions Below are instructions for each To perform gross weighing power up the unit and follow these steps 1 Empty the scale and press ZERO key to zero the display 0 is displayed 2 Place item to be weighed on the scale Weight is displayed To perform a net weighment power up the unit and follow these steps 1 Empty the scale and press ZERO key to zero the display 0 is displayed 2 Place item to be tared on the scale Weight is displayed 3 Press the TARE key 0 is displayed and the NET annunciator lights 4 Place material to be weighed on the scale Net weight of material is displayed 5 Repeatedly press the SELECT key to scroll through gross tare and net modes Remove the weight from the scale and press TARE to return to gross mode Model
14. e switch to turn the indicator on 5 The indicator powers up in normal operation mode Model E1065 Indicator User s Manual 5 Front Panel The front panel shown in Figure 2 consists of the keys and display Keys Never press a key with any thing but your finger Dam age to the overlay may result if sharp or rough objects are used Avery Weigh Tronix Ft TARE SELECT ZERO PRINT UNITS Figure 2 E1065 front panel There are seven keys on the front panel Their functions are listed below ZERO a Ey Fe 3 B Bg n 2 Z T S E Press the TARE key to perform a tare function Also acts as a left arrow key when in the User menu Press the SELECT key to toggle between Gross Net Tare Count Gross Accumulator Net Accumulator Transaction Coun ter Piece Weight and Peak Dependent on the current applica tion Also acts as an up arrow key when in the User menu Press the ZERO key to zero the display Also acts as an Escape key when in the User menu Press the PRINT key to send information to a peripheral device through the Comm port Also acts as a down arrow key when in the User menu Press the UNITS key to scroll through the available units of measure while in normal operating mode Also acts as a right arrow key when in the User menu Press the F1 key to select application specific choices Also acts as an ENTER key in the User menu Press and hold to ac cess the cutoffs
15. e e Under Target Over e Units of measure LB KG Print OP1 OP2 OP3 Pt Tare Display e Six digit seven segment 0 8 inch high LED Display rate e Selectable 1 2 5 10 Analog to digital conversion rate e 100 times per second Unit of measure e Pounds kilograms custom Capacity selections e 999 999 with decimal located from zero to five places Incremental selections e Multiples and sub multiples of 1 2 5 Programmable selections e Zero range motion detection automatic zero tracking five point linearization Time and date RAM e Battery backed up real time clock and RAM stan dard Internal resolution e 53 687 100 counts per mV V per second Harmonizer digital filtering e Fully programmable to ignore noise and vibration Standard inputs e Three logic level inputs for Zero Print Tare Units F1 Start and Stop DeviceNet gt gt EtherNet IP gt ODVA Ethernet IP and DeviceNet are trademarks of ODVA PROFIBUS is a registered trademark of PROFIBUS International Standard outputs e 10 100 Ethernet Modbus TCP TCP IP SMTP DHCP Ethernet IP e PROFIBUS DP e DeviceNet e Two serial ports e RS 232 422 485 SensorComm one e RS 232 or 20mA current loop e Three cutoff outputs Serial Command Inputs Outputs e Programmable serial response to ASCII character input e SMA protocol Broadcast Self diagnostics e Display keys inputs outputs serial port A to D converter Circuitry protection e RFI EMI
16. e F1 key OP7 is displayed Scroll through all three outputs by using the left and right arrow keys Repeat steps 2 and 3 for each output Press ZERO key to exit the cutoffs setup NO as As you apply weight to the scale output one will activate below its set point and deactivate above its setpoint The same is true for the other two setpoints Each output s annunciator will light on the display when the cutoff trip value is reached Model E1065 Indicator User s Manual This section applies if your indicator has the Peak application active Peak Weighing Only the highest stable weight applied to the scale is displayed in the Peak application when the peak weight value is selected to be displayed Peak weight is designated by the green peak LED annunciator See illustration at left As a reminder that you are in peak mode a green annunciator is lit to the right of the weight display 1 Add weight to the scale Weight is displayed 2 Remove weight Peak weight is displayed 3 To clear the peak value be sure scale is empty and press the F1 key 0 is displayed 4 Repeat steps 1 3 5 Press the SELECT key to cycle through Gross Tare Net and Peak Using Cutoffs If enabled you can use the cutoff trips function while in the peak applica tion Cutoffs are enabled in a password protected menu See the Service Manual for instructions Follow these steps to set up to three outputs Choose the
17. e F1 key to accept the value 4 Place item s on the scale and the display will show if the weight is over under or acceptable based on the limits you have set You can repeatedly press the SELECT key to view the following from the gross weight display 1st press Net annunciator lights and net weight is displayed 2nd press Tare annunciator lights and tare weight is displayed 3rd press Display toggles between HI and the upper weight tolerance in the current unit of measure 4th press Display toggles between LO and the lower weight tolerance in the current unit of measure 5th press Display returns to gross weighing mode 1 With your target weight set as described above place your item on the scale If the weight is within the upper and lower tolerances you set the TARGET annunciator lights If not the upper or lower segments will be lit 2 Repeat step 1 for all products of this weight Follow these steps to setup and use the checkweigher in sample mode 1 Zero the empty scale then place a sample of the correct weight on the scale Weight is displayed 2 Press the F1 key The weight is captured the display reads 0 net weight and your indicator is ready to use as a checkweigher The target weight will be the same as your sample item and the target will stay lit when ever an item s weight is within 1 division of the target weight You can repeatedly press the SELECT key to view the following from the
18. eatedly 3rd press Display toggles between showing ACCUM and pressing the SELECT key will gross total of all weighments 4th press Display toggles between showing ACCUM and net total of all weighments 5th press Display toggles between showing TOTAL and num ber of weighments 6th press Display returns to gross weigh mode only show the gross net and tare values You need the supervisor s password to clear the accumulator See the Service Manual for instructions Model E1065 Indicator User s Manual 11 Using Cutoffs in the Accumulator Application Choose the first digit using the UP or DOWN keys Use the LEFT and RIGHT keys to advance or backspace through the entry oD T ad 0 el F1 TARE S ZERO Q iat 4 ESCAPE J gt ENTER 12 If enabled you can use the cutoff trips function while in the accumulator application Cutoffs are enabled in a password protected menu See the Ser vice Manual for instructions Follow these steps to set up to three cutoffs 1 With the indicator powered up press and hold the F1 key until OP1 is displayed 2 Press the PRINT key The current value for OP1 is displayed 3 Press F1 to accept this value OR Key in a value using the numeric entry procedure see note at left and press the F1 key OP1 is displayed gt Scroll through all three outputs by using the TARE or UNITS key 5 Repeat steps 2 and 3 for each output 6 Press ZERO key SAVE is disp
19. ece weight by keying in the weight with the keypad and pressing and holding the F1 key You can scroll through the following information by using the SELECT key From count display press SELECT The word Piece and the piece weight toggle on the display press SELECT The word Cnttot and count total toggle on the display press SELECT The word Total and the total number of count transac tions toggle on the display press SELECT Gross annunciator lights and the gross weight is dis played press SELECT Net annunciator lights and the net weight is displayed press SELECT Tare annunciator lights and the tare weight is displayed press SELECT The counts display is shown again Model E1065 Indicator User s Manual 21 Using Cutoffs in the Counting Application Choose the first digit using the UP or DOWN keys Use the LEFT and RIGHT keys to advance or backspace through the entry 850800 TARE SELECT ZERO PRINT UNITS 22 If enabled you can use the cutoff trips function while in the counting appli cation Cutoffs are enabled in a password protected menu See the Service Manual for instructions Follow these steps to set up to three outputs 1 With the indicator powered up press and hold the F1 key until OP7 is displayed 2 Press the PRINT key The current value for OP1 is displayed 3 Press F1 to accept this value or ZERO to abort OR Key in a value see note at left and press th
20. first digit using 1 With the indicator powered up press and hold the F1 key until the UP or DOWN keys Use OP1 is displayed the LEFT and RIGHT keys to advance or backspace through 2 Pressthe PRINTkey the entry er The current value for OP1 is displayed on Q E Faf lol Press F1 to accept this value or ZERO to abort ee E Eo to OR i li Key in a value see note at left and press the F1 key ROSE eee ee OPI is displayed wo Scroll through all three outputs by using the left and right arrow keys Repeat steps 2 and 3 for each output Press ZERO key to exit the cutoffs setup NO as Press F1 to save the changes or ZERO to abort the changes The unit returns to checkweigher mode with the saved outputs active 8 As you apply weight to the scale output one will activate below its set point and deactivate above its setpoint The same is true for the other two setpoints Each output s annunciator will light on the display when the cutoff trip value is reached 9 As weight is removed the displayed weight will remain unchanged due to being in peak mode but the OP annunciators will go out as each cutoff is reached Model E1065 Indicator User s Manual 23 Communications The default serial port parame ters are 9600 baud 8 databits no parity and 1 stop bit Stop bits for the serial com munication are preset to 1 stop bit This is not configu rable The E1065 provides an RS 232 output f
21. iding process control interface and data management These same fea tures are also available when used with applications using bench scales and floor scales The display includes a multi colored multi segmented fan graph for fast visual awareness for checkweighing Also the indicator can perform counting functions peak weight functions and act as a remote display In addition to connecting to network interfaces the Model E 1065 can con nect to printers remote display computers and one SensorComm There are three setpoint control outputs and it can accommodate three foot switch inputs for Zero Print Tare Units F1 Start and Stop Major sections of this manual are headed by titles in a black bar like Intro duction above Subheadings appear in the left column Instructions and text appear on the right side of the page Occasionally notes tips and special instructions appear in the left column Unpack your indicator and check for any shipping damage If shipping dam age is found save all packing materials and contact the shipping company immediately 1 Use the included material and install the indicator into an IP54 enclo sure 2 Connect all necessary cables to the appropriate connector on the back of the indicator See Figure 1 The function of each connector and pinout is clearly marked Figure 1 Connection panel on the E1065 3 Plug the power transformer into an appropriate wall outlet 4 Press and release th
22. igure 6 Limits mode Sample Mode Place a correct weight product on the scale and press the F1 key The indicator will use this weight to run the display Upper and lower limits will automatically be 1 division above and below the target weight respectively Figure 7 shows how the graphic display works in Sam ple mode Each graduation is equal to 1 scale division The TARGET light stays lit if weight is 1 division of the target weight TARGET In ttl Ud Each graduation 1 division Figure 7 Sample mode Directions for using each mode follows Model E1065 Indicator User s Manual 17 Limits Mode Entering Uppe and Lower Limits Choose the first digit using the UP or DOWN keys Use the LEFT and RIGHT keys to advance or backspace through the entry a AHO ES Gia GI Gov is ESCAPE gt ENTER l You can repeatedly press the SELECT key to view the items listed in the Sample and Limits modes on this page Performing a Checkweighment in Limits Mode Sample Mode Using Product to Set Target Weight 18 Follow these steps to setup and use the checkweigher in limits mode 1 Empty the scale press the ZERO key to zero the display then press the F1 key Hi is displayed 2 Key in the upper weight limit using the numeric entry procedure Press the F1 key to accept the value or ESC to skip LO is displayed 3 Keyin the lower weight limit using the numeric entry procedure Press th
23. layed 7 Press F1 to save the changes or ZERO to abort the changes The unit returns to normal operation mode with the saved outputs active 8 As you apply weight to the scale output one will activate below its set point and deactivate above its setpoint The same is true for the other two setpoints Each output s annunciator will light on the display when the cutoff trip value is reached Model E1065 Indicator User s Manual _ _ e a __TTTyw zs lt This section applies if your indicator has the batching application active Batch Weighing d A The batching application has a recipe with up to eight ingredients In the recipe the following items are set Batch type can be by weight percentage or gross Each explained below Weight Batches are all the same size and the weight of each ingredient is predetermined by the recipe Percentage Batch size is chosen by the operator and each ingredi ent is determined by the percentage set in the recipe Gross Each ingredient runs until the gross weight on the scale reaches the value that was set regardless of the weight on the scale when the batch was started After a batch has been started it can be aborted by pressing Batching mode can be Manual Automatic Filling or Continuous the F1 key Manual If the recipe is set up for manual mode you press the F1 key to start the batch and you need to press the F1 When in Manual Mode you key each time a setpoint i
24. n this sampling method you can count out the specified number of items onto the scale and when you are ready press the F1 key and the scale starts to calculate piece weight and then shows the count Each method is described below Bulk Sampling 1 In gross weight mode press the F1 key A numeric value is displayed This is the current sample size 2 Accept the current sample size by pressing F1 Choose the first digit using OR the UP or DOWN keys Use Enter a new sample size see note at left and press F1 the LEFT and RIGHT keys to Zeroin is briefly displayed This shows the indicator is zeroing advance or backspace through itself Add is then displayed the entry Sha E 3 Place the correct sample size on the scale all at the same time P i B O If the sample meets the minimum sample requirements Busy is Co ESCAPE J pr ms briefly displayed followed by one of two possible outcomes a Ifthe weight is stable the display will show the correct number of parts on the scale and the green annuciator is lit The display is showing counts b Ifthe sample was unstable Abort is displayed and the display when the green annunciator on returns to gross weight mode Repeat steps 1 3 using a larger the right of the display is lit sample size 4 Place the parts on the scale to be counted 5 You can accumulate the counts and track the number of transactions by pressing the PRINT key while in count mode See Displaying Count
25. or data transmission to a peripheral device Refer to the Service Manual for RS 232 interface connections If your indicator has a peripheral device connected from the gross net weighing mode press the PRINT key to transmit the selected output s The PRINT annunciator will illuminate while data is transmitted and the data configured to be printed will be output to the printer Print Format 1 for general weighing application G 1234 56 Ilb lt CR gt lt LF gt T 34 56 Ib lt CR gt lt LF gt N 1200 00 Ib lt CR gt lt LF gt Print Format 1 for counting application Count 12230 Print Format 1 for peak application 12230 Ib lt CR gt Error Messages 24 The following are displays you may see if problems occur or if invalid opera tions are attempted with your indicator Display Description Over range weight Under range weight Hn E The unit cannot perform a function GERI E I Displayed while a key is pressed when attempting to IL O modify a sealed selection without edit privileges Model E1065 Indicator User s Manual Indicator Diagnostics The user menu lets you test various functions of the indicator The user Testing Indicator menu is shown in Figure 8 Instructions for using the menu are found below Functions Normal Operation Mode Press and hold ZERO for 3 5 seconds RISAdO TARE SELECT rA 0 PRINT UNITS ESCAPE J m ENTER Scroll in 111 and press F1 Serial
26. right Repeatedly press the UP SELECT or DOWN PRINT key until 7 appears on the display Press the F1 key to enter the value Model E1065 Indicator User s Manual Menu Mode User menu password is 111 You must key in the password within 10 seconds or the dis play returns to normal opera tion mode Choose the first digit using the UP or DOWN keys Use the LEFT and RIGHT keys to advance or backspace through the entry 850800 TARE SELECT ZERO PRINT UNITS The E1065 has a User menu you use to do the following e See software information e Perform a display test e Perform a button test e Perform a serial port test e Audit the number of configurations and calibrations performed 1 Access the User menu by pressing and holding the ZERO key for 3 5 seconds Release the key when PASS_ is displayed 2 Use the arrow keys to scroll in the User menu password 111 and press F1 See note at left Figure 5 shows a flowchart of the User menu items Use the keys shown in the box in Figure 5 to navigate through the menu and choose the items you want Normal Operation Mode Press and hold ZERO for 3 5 seconds Scroll in 111 and press F1 Software mV V Display Button Port 1 Port 2 version test test and revision Pass Fail Pass Fail Figure 5 User menu flowchart Specific instructions on the User menu appear in the section Indicator Diag nostics later in the manual Model E1065 Indicator User s M
27. rt each batch The Basis of each ingredient can be weight time or pulse counts Weight If an ingredient basis is weight the output activates at the appropriate time and deactivates when the weight set in the recipe is reached Time If an ingredient basis is time the output activates for the time set in the recipe and then deactivates Counts If an ingredient basis is counts from a pulse counter the output activates for the value based on pulse count units set in the recipe and then deactivates Model E1065 Indicator User s Manual 13 14 In filling mode the process can be changed by changing the value s of the cutoffs Follow these steps to set up the three outputs 1 With the indicator powered up press and hold the F1 key until OP7 is displayed 2 Press the PRINT key The current value for OP1 is displayed 3 Press F1 to accept this value or ZERO to abort or key in a value see note at left and press the F1 key OP7 is displayed Scroll through all three outputs by using the left and right arrow keys Repeat steps 2 and 3 for each output Press ZERO key to exit the cutoffs setup Press F1 to save the changes or ZERO to abort the changes Nodo A In automatic or manual mode a recipe must be setup The recipe values are set in a password protected menu However a shortcut can be used to change the amount of each ingredient To access this shortcut menu 1 Press and hold the F1 key until ingr
28. s reached to activate the next must press F1 during ingredient ingredient output See important note at left filling to abort the operation If you press F1 during a config ured delay time the key press is ignored An F1 press after the delay time will start the next Filling In FILL mode any recipe that has been setup is ignored ingredient The filling process is run based on the values set for the cutoffs In order to complete the filling process at least one cutoff must be enabled Automatic If the recipe is set up for automatic mode you press the F1 key to start the batch and each output is activated and deactivated automatically by the indicator Pulse count requires optional Press the F1 key to start the filling process naire 1 a If cutoff 1 is enabled and the net weight on the scale is below the value of the cutoff cutoff 1 will come on b If cutoff 2 is enabled and the net weight on the scale is below the value of the cutoff cutoff 2 will come on c If cutoff 3 is enabled and the net weight on the scale is below the value of the cutoff cutoff 3 will come on 2 Each cutoff will remain on until its cutoff value is met 3 Press the F1 key again to restart the filling process Continuous Continuous batching mode This mode is very close to the Auto mode but in continuous mode another batch is started immediately after the previous batch has fin ished In auto mode the user must press the F1 key to sta
29. test Each key you press will be reflected on the display screen to confirm the button is functioning correctly The ZERO key is excluded from this test It is used to stop the testing and return to the menu item Press ZERO key to stop the button test BUTTON is displayed Press the UNITS key SERIAL is displayed This is the serial test item Press the PRINT key to access the serial test PORTI is displayed If you jumper the transmit and receive lines on the serial port and press the PRINT key the display should show PASS If there is a problem the display will show FAIL Press the SELECT key after checking the port function PORT71 is displayed Press the UNITS key PORT 2 is displayed Repeat the test from step 14 to check the port Press the SELECT key twice to exit the serial test SERIAL is displayed Press the SELECT key TEST is displayed Press the UNITS key AUDIT is displayed Model E1065 Indicator User s Manual 20 21 22 23 24 25 26 Th Press the PRINT key CFG is displayed This stands for the configuration audit counter Press the PRINT key to see the number of times the configuration has been altered on this indicator Press the SELECT key CFG is displayed Press the UNITS key CAL is displayed This stands for the calibration audit counter Press the PRINT key The number of times the indicator has been calibrated is dis played Press
30. the ZERO key twice The display returns to normal operation mode is completes the User menu Model E1065 Indicator User s Manual 27 28 Model E1065 Indicator User s Manual Model E1065 Indicator User s Manual 29 30 Model E1065 Indicator User s Manual Weigh Bar is a registered trademark of Avery Weigh Tronix and may be registered in certain jurisdictions All brands and product names used within this document are trademarks or registered trademarks of their respective holders Avery Weigh Tronix LS Avery Weigh Tronix USA 1000 Armstrong Dr Fairmont MN 56031 USA Telephone 507 238 4461 Facsimile 507 238 4195 e mail industrial weigh tronix com www wtxweb com Avery Weigh Tronix UK Foundry Lane Smethwick West Midlands England B66 2LP Tel 44 870 90 34343 Fax 44 121 224 8183 Email info awtxglobal com Web site www averyweigh tronix com Avery Weigh Tronix Canada ULC 217 Brunswick Boulevard Pointe Claire QC H9R 4R7 Canada Telephone 514 695 0380 Toll free 800 561 9461 Facsimile 514 695 6820 www weigh tronix ca
31. trips menu Press and release the ON OFF key to turn the unit on Press and hold the key until the unit turns off Model E1065 Indicator User s Manual There are several annunciators around the edge of the display Figure 3 Annunciators explains each one Checkweighing graph Custom Unit Kilogram Motion Pound Gross weight Center of zero outhut 3 Accumulator Net weight Output 2 Count or Peak Weight Tare weight Output 1 H twaikar Preset Tare Print SensorComm status Figure 3 Annunciators Bottom LED color Center of Zero Lights when weight on the scale is within the zero range Chosen as SCOM or Network in Motion Lights during scale motion Goes out when scale is configuration Can t be both stable SCOM Gross Lights when gross Welgni i displayed Red a cell has been ghosted Net Lights when net weight is displayed Check the ghost log Tare Lights when tare weight is displayed Green a sensorcomm error Print Lights when print format sent through serial port has occurred Check the error log OP 1 Lights when output one is activated Off Scale is function OP 2 Lights when output two is activated ing normally OP 3 Lights when output three is activated Network 1 or 2 PT Lights when preset tare is active Red A network error has oc Network amp This is configurable to light to show status of the Net curred Check the network set SensorComm work 1 Network 2 or SensorComm See note at left
32. vates Add weight to the scale When the weight reaches the percentage of the batch size set in the recipe for ingredient 3 OP3 annunciator light goes out and output 3 deactivates Empty the scale and repeat steps 1 8 for the next batch Model E1065 Indicator User s Manual Checkweighing The smallest upper limit seg ment of the fan graph shown in Figure 6 will be lit when in the checkweighing mode as a reminder that this application is active The graph is based off of net weight so if a tare is active only the net weight is considered for checkweighing If there is no tare gross weight is used as the basis for the graph This section applies if your indicator has the checkweighing application ac tive Applications are activated through a password protected menu See the Service Manual for instructions Checkweighing allows a quick visual check of the acceptability or unaccept ability of an item s weight You set your target weight in one of two ways It depends on how your indi cator is configured The choice is made in the password protected Supervi sor menu which is explained in the Service Manual Your unit will be configured with limits mode or sample mode Each are explained below Limits Mode Enter the upper and lower limits for the item and the indicator will use those values to run the display See Figure 6 Lower limit YL Tee ll Md Each graduation 1 division Upper limit F