Home

tdi turbotwin - Ignition Service & Supply

image

Contents

1. There is a natural gas vent port in the turbine housing that is plugged for compressed air use This vent is used to remove any natural gas that could leak past the primary turbine shaft seal Remove this 3 8 NPT plug and install a line to carry gas away from the starter area WARNING Do not connect the turbine housing vent line to the turbine exhaust line Exhaust gas can pressurize the housing 3 5 PIPING SYSTEM Only type approved metallic hose assemblies are approved in permanently pressurized compressed air lines of starters Non metallic hose assemblies are allowed only in case the piping system will be emptied after the starting procedure Publication T1 702 Rev 1 Issued January 22 2001 Pipe unions must be type approved by GL Downstream of the pressure regulator a pressure relief valve is to be provided 3 6 BACKLASH Backlash is the free play between the mesh of two gears Figure 15 shows the backlash between two gears Maintaining the proper gear backlash setting allows the gears to mesh smoothly Proper backlash and alignment allows smooth engagement disengagement of the pinion gear and loads the tooth face surfaces evenly producing longer gear life The correct backlash setting for 6 8 diametral pitch gearing used on larger engines is as follows 015 inch 025 inch Minimum backlash Maximum backlash To check the backlash the pinion will need to be rolled out onto the end of the drive prior t
2. 1 1 DESCRIPTION All models feature three basic subassemblies a unique two stage turbine motor section a planetary gearbox section and an inertia drive assembly The two stage motor section features greater stall torque than a single stage turbine plus aerodynamic speed control Page 2 This aerodynamic speed control helps protect the TURBOTWIN starter from damage caused by starter motor over speed The T100 TURBOTWINS employ a 7 5 1 or 9 1 ratio planetary gearbox This low gear ratio allows the turbine motor to spin at low speeds for long bearing life typical 3000 rpm pinion speed the turbine is cruising at a low 22500 rpm 7 5 1 ratio Reliability and part commonality are designed into all TURBOTWINS A simple and reliable inertia drive delivers the torque to the pinion The pinion is thrown out to engage the engine s ring gear by the turbine motor s acceleration Lighter weight rotating parts used in the TURBOTWIN provide low inertia and even softer engagement In the event of over pressure the friction clutch used in every TURBOTWIN protects ring gear teeth from static torque overloads In addition an inertia engaged starter eliminates the need for complex pre engagement control plumbing and is easier to install and maintain than pre engaged type starters Compressed air or natural gas is used to power T100 TURBOTWIN air starters through the inlet port The air or gas is expanded through the first nozzle or stat
3. line length must be kept to a minimum TDI recommends that hose or flex couplings are installed to eliminate possible leakage caused by strain on the supply line Normally an air strainer is not required However in dirty environments use of a 40 mesh Y strainer is recommended The T100 TURBOTWIN series is highly tolerant of dirt in the air line however starter life can be increased with the use of an air strainer TDI TURBOTWIN rrom TECH DEVELOPMENT INC A pressure regulator is required when the air supply pressure is great enough to exceed the starter operating pressure at the inlet port and or the maximum torque A manual ball valve may be used to admit drive air gas to the starter The manual valve should be located in a safe position away from the engine A preferred valve is pilot operated which can be pneumatically or electrically actuated The valve should be located close to or even on the starter inlet for best performance Pneumatic or electrical control lines may be routed virtually anywhere for the customer s preferred operating station This type of valve actuates from a fully closed to a fully open position very rapidly TDI offers a variety of relay valves such as P N RLVA 25683 001 2 01 which is a 1 1 2 port pneumatically actuated valve The supply line should be dry fitted for proper alignment location prior to final assembly All pipe threaded joints should be sealed with Loctite Pipe Thread Sea
4. 0 27791 3 624 3 621 PILOT 92 05 91 97 PILOT DIMENSIONAL DATA TDI TURBOTWIN T100 B Page 10 Publication T1 702 Rev 1 Issued January 22 2001 4 91 124 71 2 NPT INLET 4 22 107 19 3 8 GAS VENT PORT OPPOSITE SIDE 1 4 NPT PRESSURE CHECK PORT 10 53 267 46 6 SCREWS FOR 60 INCREMENTS OF ANGULAR POSITION EXHAUST SCREEEN GUARD lt 2 28175 FOR AIR ONLY OTHER EXHAUST OPTIONS EXHAUST CLOSURE PLATE 1100 27068 3 NPT MALE 90 ELBOW P N 7100 27900 MUFFLER SHORT P N 1100 27075 MUFFLER LONG P N 7100 27074 4 STRAIGHT PIPE FITTING P N 7100 27791 10 24 260 10 gt 6 76 171 70 ome MAX i L TDI TURBOTWIN TECH DEVELOPMENT INC 10 39 263 91 STANDARD MESH 1 25 31 75 6 SCREWS FOR 60 INCREMENTS STANDARD OF ANGULAR POSITION MESH 88 22 35 SHOWN STANDARD MESH 6413 104 90 FLYWHEEL 5 999 5 995 PILOT 0152 375 152 273 PILOT 720 182 88 7 40 187 965 10 76 273 30 LUNG MESH 125 lt 31 75 LONG MESH LH CCW ROTATION RH CW ROTATION P cu 3X 687 17 450 HOLES 25 6 35 OFFSET LN 40 10 165 81 20 57 DIMENSIONAL DATA TDI TURBOTWIN T100 D T100D MOUNTING FLANGE Publication T1 702 Rev 1 Issued January 22 2001 11 TDI TURBOTWIN rrom TECH DEVELOPMENT INC 3 8 NPT GAS VENT PORT 19055 XI 6 76 6171 70 1 4 PRESSURE CHECK PORT 18 45 62 SCREWS FOR 30 INCREM
5. 1 PILOT 692 05 91 97 gt PILOT R 2 39 60 7D 13 TDI TURBOTWIN rrom TECH DEVELOPMENT INC T112 B T112 D Performance Curve TORQUE 12 Nozzles Compressed Air 7 5 1 RATIO POWER Nm LB FT HP KW 476 350 100 74 6 Inlet Pressure SCFM Nm3 h 150 psig 1360 2312 120 psig 1090 1853 90 psig 860 1462 60 psig 610 1037 408 300 15 20 25 30 Pinion Speed rpm 100 T121 B T121 D Performance Curve 21 Nozzles Compressed Air 7 5 1 RATIO POWER HP KW TORQUE 100 74 6 Inlet Pressure SCFM Nm3 h 90 psig 1560 2652 60 psig 1070 2140 30 psig 620 1054 E 1000 1500 d 2500 3000 hes 4000 s 5000 5500 Pinion Speed rpm Page 14 Publication T1 702 Rev 1 Issued January 22 2001 TDI TURBOTWIN rrom TECH DEVELOPMENT INC T106 F Performance Curve TORQUE 6 Nozzles Compressed Air 7 5 1 RATIO 238 175 me Inlet Pressure SCFM Nm3 h 2 150 psig 680 1156 Maxim E orgu 120 psig 550 935 ED ae 90 psig 430 60psig 310 527 136 100 IISA Zeen E i CMSs 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 Pinion Speed rpm T112 F Performance Curve Nm LB FT 12 Nozzles Compressed Air 7 5 1 RATIO 238 175 Maximum Tprque Inlet Pressure SCFM S smitted by Dri 90 psig 860 60 psig 610 30 psig 370 204 150 170 125 136 100 Vos NV TI CTT 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 Pinion Speed rp
6. ENTS OF ANGULAR POSITION eo c8 EXHAUST SCREEEN GUARD 2 28175 FOR AIR ONLY SHOWN OTHER EXHAUST OPTIONS EXHAUST CLOSURE PLATE 7100 27068 LH CCW gt ROTATION 3 NPT MALE 90 ELBOW P N T100 27900 MUFFLER SHORT P N 7100 27075 MUFFLER LONG P N T100 27074 4 STRAIGHT PIPE FITTING P N 7100 27791 SAE 3 MOUNTING FLANGE DIMENSIONAL DATA TDI TURBOTWIN T100 F 2 06 52 32 Page 12 175 1905 FLYWHEEL RH CV ROTATION 3 624 3 621 PILOT 092 05 91 972 PILOT Publication T1 702 Rev 1 Issued January 22 2001 TDI TURBOTWIN rrom TECH DEVELOPMENT INC 3 8 NPT GAS VENT PORT NEN 96 243 8 66 76 6171 70 2 NPT INLET 19 3 490 22 MAX OPEN POSITION 1 4 NPT 6 SCREWS FOR 30 INCREMENTS PRESSURE CHECK PORT OF ANGULAR POSITION 18 7 475 00 CLDASED POSITION ecu 10 3 26L6 547 131 322 18 4575 60 SCREWS 60 INCREMENTS OF ANGULAR POSITION 2 0 lt 5 82 EXHAUST CLOSURE PLATE 2 27271 FOR AIR ONLY SHOWN OTHER EXHAUST OPTIONS EXHAUST SCREEEN GUARD 2 28175 FOR AIR ONLY 3 MALE 90 ELBOW P N 1100 27900 MUFFLER SHORT P N 1100 27075 MUFFLER LONG P N 7100 27074 4 STRAIGHT PIPE FITTING P N 1109 27791 LH CCW ROTATION SAE 3 MOUNTING FLANGE 40 10 16 81 20 575 DIMENSIONAL DATA TDI TURBOTWIN T100 P 2 06 52 38 Publication T1 702 Rev 1 Issued January 22 2001 449 114 05 ENGINE FLYWHEEL s RH CW ROTATION 93 624 3 62
7. OTWIN models are turbine driven starters with an inertially engaged starter drive Depending on the starter model and engine installation the TURBOTWIN starters have applications ranging from 1200 CID 20 Liters on diesel engines and up to 15000 CID 250 Liters on gas engines The TURBOTWIN models are suited to operate within a wide range of inlet pressures and ambient temperatures The engine size and parasitic loading will determine the exact minimum pressure that will assure reliable starting The T100 TURBOTWIN starters are designed for operation with compressed air or natural gas materials used are compatible with sour natural gas and marine environments Small amounts of foreign matter or liquid in the air stream will not adversely affect TURBOTWIN starters As with all other TDI starters no lubrication is required in the air supply Please review the rest of this manual before installing the T100 TURBOTWIN series air starter WARNINGS CAUTIONS AND NOTES Certain types of information are highlighted in this manual for your attention WARNING used where injury to personnel or damage to the equipment is likely CAUTION used where there is the possibility of damage to the equipment NOTE used to point out special interest information NOTE Throughout this manual the term air is used to designate the starter drive medium Unless other wise stated air means either compressed air or natural gas
8. SS Publication T1 702 Rev 1 TECH DEVELOPMENT INC SEHR INSTALLATION AND MANUAL MODELS T100 B T100 D T100 F T100 P TURBOTWIN Engine Air Starters AN 95 414 From Tech Development Inc 6800 Poe Ave eDayton OH 45414 Tel 937 898 9600 eFax 937 898 8431 Publication T1 702 Rev 1 Issued January 22 2001 SECTION mmh Cono 7 0 TDI TURBOTWIN rrom TECH DEVELOPMENT INC TABLE OF CONTENTS SUBJECT GENERAL INFORMATION DESCRIPTION PRODUCT IDENTIFICATION PERFORMANCE ORIENTATION OF THE STARTER GENERAL INSTALLING THE STARTER SUPPLY LINE INSTALLATION NLET PRESSURE PORT EXHAUST PIPING NATURAL GAS INSTALLATION PIPING SYSTEM BACKLASH STARTER OPERATION BASIC OPERATION AUTOMATED START PANEL PREVENTIVE MAINTENANCE TROUBLE SHOOTING GUIDE TURBOTWIN WARRANTY LIST OF FIGURES 1 TURBOTWIN PART NUMBER LISTING 2 MODEL T112B T121B INSTALLATION DRAWING 3 MODEL T106F T112F INSTALLATION DRAWING 4 MODEL T112D T121D INSTALLATION DRAWING 5 MODEL T112D T121D INSTALLATION DRAWING PAGE Om PEP RWW Ww STD MESH TDI TURBOTWIN rrom TECH DEVELOPMENT INC 1 0 GENERAL INFORMATION This manual provides instructions for the installation and operation of the TDI T100 TURBOTWIN Starters Series B D F P If there are questions not answered in this manual please contact your TDI TURBOTWIN distributor or dealer for assistance The T100 TURB
9. aks Check the 1 4 NPT pipe plug or a pressure gauge transducer that may be connected to the pressure port on the starter inlet WARNING Do not operate the TDI TURBOTWIN starter with air pressure greater than the pressure rating on the nameplate This pressure is measured at the starter inlet while the starter is running The maximum operating pressure limit is the inlet pressure measured at the starter s inlet pressure check port In order to check the starter 1 4 pipe tap connection is provided in the inlet housing to attach a pressure gauge transducer The maximum pressure assumes an open exhaust standard turbine exhaust guard The standard exhaust guard causes no back pressure The static non flowing supply pressure will always be higher than the operating dynamic pressure The maximum pressure limit proof pressure that the TDI TURBOTWIN starter housings may be subjected to is 600 PSIG 42 BAR System pressure that exceeds the maximum operating limit must use a pressure reducing device to ensure that the operating pressure limit to the TDI TURBOTWIN starter is maintained System static pressure that exceeds the 600 PSIG 42 BAR limit must in addition to pressure reducer devices incorporate a pressure relief valve set below 600 PSIG 42 BAR in the supply air line NOTE For maximum life of the starter pinion and for the protection of the engine ring gear limit the operating pressure to that n
10. ay be attempted after the engine and the starter has come to rest CAUTION Do not engage the starter while the engine is running The drive air pressure is the primary starter control parameter It is important especially on new installations to measure this pressure during several engine starts The secondary parameter is the starter pinion speed This speed is usually measured by knowledge of the engine starting speed and the starter cranking ratio The cranking ratio is the number of ring gear teeth divided by the number of pinion teeth The starter pinion speed is then found by multiplying the engine speed by the cranking ratio The pinion speed is usually 2000 3500 rpm at typical engine starting speed 4 2 AUTOMATED START PANEL The starter drive pressure measured at the starter inlet must be set noted above for maximum life of the starter pinion and for the protection of the engine ring gear limit the operating pressure to that necessary to start the engine at its most difficult starting conditions The speed control parameter will then need to be set Engine starting speed along with the cranking ratio number can be used to determine starter pinion speed The pinion speed is usually 2000 3500 rpm for a typical engine starting speed Once the start sequence has begun the air is admitted to the starter The starter begins to accelerate the engine Once the firing speed of the engine is reached the automated s
11. d of one year from date of purchase by such user The warranty period shall begin on the actual delivery date to the original user or twelve 12 months from the date of shipment from TDI whichever comes first The conditions of this warranty are a TDI is notified within this period by return of such product to TDI or its authorized distributor or dealer transportation prepaid by user b such product has been installed according to TDI s specifications c such product has not been misused abused or improperly maintained by user d the defect is not the result of normal wear and tear and e such starter product has not been repaired with parts not manufactured or authorized by TDI and TDI installation and repair procedures as outlined in the appropriate manual were properly followed Tech Development Inc shall at its option either repair or replace without charge any such starter product found by TDI s examination to be defective or by mutual agreement refund the user s purchase price in exchange for such starter product Repairs or replacements are warranted for the remainder of the original warranty period Tech Development Inc makes no other warranty and IMPLIED WARRANTIES INCLUDING ANY WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED This warranty constitutes the entire obligation of Tech Development Inc relating to the sale and use of such product and TDI s maximum liability is limited to
12. e transducer may be Page 4 installed at the pressure check port and electrical lines routed to a digital display at the operator s station This pressure port is invaluable in diagnosing air starter and or installation problems 3 3 EXHAUST PIPING The turbine exhaust may be plumbed away from the starter area All starters using natural gas must be piped according to industry codes and local regulations The performance of a turbine starter will be decreased because of back pressure when smaller than recommended exhaust piping is installed If back pressure hampers starter performance compensation can be made by increasing the supply pressure Consult your TDI distributor for advice Exhaust piping should be routed downward to help prevent any accumulation of condensation in the starter motor If the overhung section of the starter is not otherwise supported TDI recommends supporting the exhaust piping with a suitable bracket s Exhaust piping should be routed downward to help prevent any accumulation of condensate in the starter motor 3 4 NATURAL GAS INSTALLATION The installation of the starter using natural gas is similar to the air installation except all fittings piping valves and regulators must be compatible with natural gas Proper control of natural gas is a major consideration when used in the starter system All starters using natural gas must pipe the exhaust according to industry codes and local regulations
13. ecessary to start the engine at its most difficult starting conditions All appropriate local pressure codes and pressure limitations on other system components must be adhered to and supersede the guidelines given in this manual Consult your TDI distributor if you have exhaust plumbing that creates back pressure and reduces starter performance You may be able to increase the supply pressure to restore the lost power Follow the engine manufacturer s instructions for starting the engine 4 1 BASIC OPERATION TDI TURBOTWIN rrom TECH DEVELOPMENT INC The basic operation of the starter is as follows Pressurized air or natural is admitted to the starter by opening of the manual or relay valve The air expands through the turbine which produces shaft rotation and torque The acceleration of the drive assembly causes the pinion to advance and engage the ring gear of the engine The starter motor torque causes the engine to accelerate This acceleration causes the pinion to be disengaged from the ring gear The fuel and ignition systems now fire the engine Closing the relay valve stops the starter The operator may decrease starter life by the continual operation of the starter after the engine has started Upon a successful engine start turn the air off to the starter immediately Minimizing the time the starter is operating unloaded i e the engine is running will maximize starter life If a start is aborted a restart m
14. et supply piping too small B Supply piping must be a minimum of 1 5 diameter Pressure regulator orifice too C Increase orifice size or replace pressure regulator small D Inlet supply line valve ball D Install larger valve gate relay plug too small E In line lubricator installed in E Remove lubricator supply line F Y Strainer in supply line F Clean strainer clogged G Excessive back pressure G Clean exhaust piping or increase size to at least the exhaust restricted minimum diameter recommended H Damaged turbine nozzle H Replace turbine nozzle Broken started drive 1 Repair or replace starter drive J Wrong rotation starter J Replace with starter or proper rotation K Wrong size starter K Check the Application Guide for the correct starter 4 Engine cranks too A Inlet air pressure too high A Decrease air pressure in 10 PSIG 0 6 BAR quickly increments OR If there is a manual shut off valve in the supply line partially close it OR Install a restriction orifice in the inlet supply line B Wrong size starter B Check the Application Guide for the correct starter Publication T1 702 Rev 1 Issued January 22 2001 TDI TURBOTWIN rrom TECH DEVELOPMENT INC 7 0 WARRANTY TDI TURBOTWIN ENGINE STARTER WARRANTY Tech Development Inc TDI warrants to the original user of the TDI TurboTwin Model T30 Series air starters to be free from defects in material and workmanship for a perio
15. lant TDI P N 9 94085 or equivalent for leak tight joints prior to final assembly Be sure to tighten all joints to proper torque after final assembly CAUTION In cold weather climates care should be taken while designing your installation to prevent condensation from developing in the starter system In systems with a regulator valve or relay valve there is the possibility of freeze ups A tee connection with a quick disconnect can be added to the inlet This will allow an external air source to be used to accomplish a blow start if the system freezes Once the engine has been started the other system components may be thawed CAUTION On new installations it is strongly recommended to blow out the supply line with air to remove possible dirt and welding slag prior to final connection to the TURBOTWIN starter Be sure to secure the free end of the supply line prior to blowing out the line 3 2 INLET PRESSURE PORT A 1 4 NPT port is located on the air inlet This port may be used to check the supply pressure at the starter when the starter is operating Remove the 1 4 NPT pipe plug and save for later use Install a 1 4 minimum size tubing to the port Route the tubing away from the starter to a safe location away from the engine Install a pressure gauge on the tubing This pressure monitoring line gauge may be permanently installed Use Loctite Pipe Thread Sealant or equivalent Alternately a pressur
16. ld be installed with the inlet in a position between horizontal and straight down Any condensation will be restricted to the air lines and not in the starter WARNING Do not operate this starter unless it is properly connected to an engine 3 1 SUPPLY LINE INSTALLATION WARNING Be sure to either bleed the pressurized air reservoir and or safety the system such as closing all valves prior to installing starter supply line The T100 TURBOTWIN series air starters come standard with a 2 NPT female pipe thread for the inlet connection port The supply line consists of the line from the air source a pressure regulator when necessary a manual or relay valve and the connection to the starter inlet Hard piping may be used but a section of flexible tubing should be installed at the starter to prevent leaks due to engine vibration Care must be taken to ensure that all inlet supply line piping is no less than 1 5 and all components used are capable of passing the required air flow NOTE Valves with a Cv of 40 or higher are recommended If the supply line must be longer than 20 feet the inlet supply line piping should be increased to 2 in diameter to ensure proper performance by your TURBOTWIN Because turbine starters such as the T100 TURBOTWIN series are sensitive to flow restrictions care must be taken to use uniform hose or tubing and fittings for connection of the supply line Tees elbows and
17. m Publication T1 702 Rev 1 Issued January 22 2001 TDI TURBOTWIN rrom TECH DEVELOPMENT INC Page 16 TORQUE T109 P Performance Curve Nm LB FT 9 Nozzles Compressed Air 9 0 1 RATIO 476 350 Inlet Pressure SCFM Nm3 h 408 300 150 psig 1050 ur 340 250 272 200 204 150 136 100 68 50 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 Pinion Speed rpm Publication T1 702 Rev 1 Issued January 22 2001
18. o starter installation This can be accomplished by using a hex drive wrench to rotate the turbine end of the starter while holding the pinion from rotating The pinion will simply walk to the end of the shaft An access hole to reach the turbine screw is provided in the turbine exhaust guard The starter must then be installed on the engine Checking backlash can be accomplished using a dial indicator or a simple blade type feeler gauge Because ring gears are not usually perfectly round it is necessary to Pressure Angie Pitch 2 Circle Figure 2 Checking Backlash check backlash at several six or more points around the circumference of the ring gear Average the highs and lows to allow a setting that is in the range cited above Setting the correct backlash may involve shimming and or moving the starter bracket s An adjustable starter bracket design will simplify this procedure Always re check the backlash after a ring gear replacement Liberally grease the starter s drive teeth with chassis lube and then mount the TURBOTWIN starter on the engine Tighten all mounting hardware as appropriate Make sure to use Loctite Threadlocker 290 or equivalent on the starter Publication T1 702 Rev 1 Issued January 22 2001 TDI TURBOTWIN rrom TECH DEVELOPMENT INC mounting bolts Torque the three 5 8 screws to 100 Ib ft 4 0 STARTER OPERATION Prior to operation check that all connections are tight and free from le
19. ors The high velocity gas impinges on the first stage rotor to yield torque to the gearbox The gas is further expanded through the second stage stators which impart additional torque to the second stage rotor 1 2 PRODUCT IDENTIFICATION The starter nameplate which is attached to the turbine housing contains the following information model number serial number part number direction of rotation and the maximum rated operating pressure The directions of rotation are either right hand or left hand rotation as shown in Figure 1 Right Hand rotation is defined as clockwise rotation as viewed from the pinion end of the starter and Left Hand rotation is counter clockwise rotation viewed from the pinion end of the starter The maximum operating pressure is also stamped on the nameplate This pressure is measured at the check port on the starter inlet with the starter in operation CAUTION Exceeding the maximum pressure shown on the nameplate may result in drive failure damage to the starter or damage to the engine The housing proof pressure is 600 psig and is also shown on the nameplate This means the turbine housing will not burst when subjected to a static pressure of 600 psig Publication T1 702 Rev 1 Issued January 22 2001 NS LEFT HAND ROTATION RIGHT HAND ROTATION Figure 1 Direction of Rotation viewed from Pinion End 1 3 PERFORMANCE Graphs of the performance curves feature pinion torq
20. t bearings for freedom of rotation without excessive play between races If bearings are damaged replace them with genuine TDI parts Refer to TDI Service Manual for part numbers 5 1 3 Place a small amount of chassis lube on the starter s pinion teeth 5 2 Every Three 3 Months Follow the six 6 month procedures if there is severe starter loading or extended duration crank cycles Also perform these procedures every three 3 months when starter is used for motoring the engine for maintenance or valve adjustments Motoring Crank Cycle 10 60 seconds Extended Crank Cycle 60 seconds or longer starter use only genuine TDI replacement parts The component part numbers are found in the Illustrated Parts Breakdown Publication T1 702 Rev 1 Issued January 22 2001 TDI TURBOTWIN rrom TECH DEVELOPMENT INC 6 0 TROUBLESHOOTING CHART TROUBLE PROBABLE CAUSE SOLUTION 1 Starter does not A Relay valve not fully open A Repair or replace relay valve 2 Nozzle blockage B Remove blockage or obstruction from nozzles 2 Starter does not A Broken turbine rotor A Replace all damaged parts run normal air flow B Brok trai B Repai ira from exhaust Broken gear train Repair or replace geartrain C Damaged starter drive C Repair or replace starter drive 3 Reduced Starter A Inlet air pressure too low A Increase air pressure in 10 PSIG 0 6 BAR output power increments DO NOT EXCEED OPERATING LIMIT B Inl
21. tart panel may deliver fuel to the engine The engine will begin to accelerate under its own power The starter should be dropped out of the sequence at a rpm higher than the firing speed but less than the engine idle Page 6 speed The automated start panel should monitor engine speed to determine air on and air off Do not simply use time as a control parameter Avoiding excessive operation of the starter after the engine is firing will maximize the starter life 5 0 PREVENTIVE MAINTENANCE The TDI TURBOTWIN starters provide distinct advantages of size and efficiency as compared to electric motor vane type or other turbine type starters It is important to properly install the starter to receive full benefit of these advantages Repair technicians or service organizations without turbine starter experience should not attempt to repair this machine until they receive factory approved training from TDI or its representatives Proper operation and repair of your TDI TURBOTWIN starter will assure continued reliable and superior performance for many years 5 1 Every Six 6 Months Perform the following procedures at six 6 months intervals if the normal cranking cycle is 0 10 seconds 5 1 1 Check the amount and condition of grease in the planetary gearbox If gearbox requires re greasing only use TDI grease Approximately one 1 pint of grease is needed to repack the gearbox 5 1 2 Check the turbine bearing and carrier outpu
22. the purchase price of such product at the date of purchase In no event shall TDI be liable for incidental indirect consequential or special damages of any nature arising from the sale or use of such engine starter product Page 8 Publication T1 702 Rev 1 Issued January 22 2001 TDI TURBOTWIN rrom TECH DEVELOPMENT INC USE 1 1 2 MIN HOSE OR PIPE TDI TURBOVALVE P N RLVA 25683 001 01 1 1 2 NPT IN OUT PORT NOTE FOR BEST RESULTS MOUNT THE RELAY VALVE AS CLOSE TO THE STARTER AS POSSIBLE 2 NPT STARTER INLET 4 CONTROL LINE 1 4 MANUAL CONTROL VALVE 52 93504 CAUTION THE TOTAL CONTROL LINE LENGTH FROM THE STARTER CONTROL VALVE PORT TO THE TURBOVALVE APP PORT IS NOT TO EXCEED 10 FEET FROM USE HIGH FLOW SOLENOID VALVE TDI TuRBOTwIN POWER 0 52 21981 24VDC 120 60 110 50 source 52 21981 002 12VDC 100 M e MM 5 Typical Single Starter Installation Publication T1 702 Rev 1 Issued January 22 2001 9 TDI TURBOTWIN rrom TECH DEVELOPMENT INC 66 76 6171 70 6 SCREWS FOR 30 INCREMENTS OF ANGULAR POSITION 1 4 PRESSURE CHECK PORT 6 SCREWS FOR 60 INCREMENTS OF ANGULAR POSITION EXHAUST SCREEEN GUARD 2 28175 FOR AIR ONLY SHOWN OTHER EXHAUST OPTIONS EXHAUST CLOSURE PLATE 1100 27068 LH CCW ROTATION RH CV ROTATION 3 MALE 90 ELBOW P N T100 27900 MUFFLER SHORT P N T100 27075 MUFFLER LONG P N 100 27074 4 STRAIGHT PIPE FITTING P N 710
23. ue versus pinion speed rpm at constant drive air pressures and shaft horsepower versus pinion speed at constant drive air pressures Pinion speed is shown on the horizontal axis The pinion torque is shown along the left edge vertical axis The shaft horsepower is shown along the right edge vertical axis Air consumption rates are given for the various drive pressure lines These performance curves feature air as the drive gas and have open exhaust standard exhaust guard which have no back pressure 2 0 ORIENTATION OF THE STARTER 2 1 GENERAL If the factory orientation of the starters pinion housing assembly in relation to the inlet port does not fit your engine installation these components can easily be re oriented All TURBOTWINS have the capability to rotate the inlet port relative to the drive opening for the optimum inlet port location The number of different positions is 6 to 12 depending on model 3 0 INSTALLING THE STARTER A turbine air starter does not require lubrication in the supply air Therefore if a vane type starter motor is being replaced TDI recommends that all lubrication devices and lines removed to minimize flow restrictions Publication T1 702 Rev 1 Issued January 22 2001 TDI TURBOTWIN rrom TECH DEVELOPMENT INC WARNING If a fuel pulse lubricator has previously been installed in the system disconnect and plug the line to eliminate spraying diesel fuel on the engine The starter shou