1. 9mm Curing Cap and anchor light on occlusal or bonding o surface For temporary bonding snap on 3mm Curing Cap Tacking Tip at the end of the Lens Module and apply pressure at the center of crown veneer for best contact Tack for 1 to 2 seconds then remove excess adhesives before final bonding For veneer bonding and molar cavity treatment snap on 13mm curing cap and place light in direct contact Cleaning and Disinfecting Clean and disinfect Handpiece and Charging Stand with a soft cloth or tissue damped with cleaning solution including Cavicide Lysol lsopropyl or Ethyl alcohol and equivalent Ay Do not spray soak or autoclave Use Q tips to clean lens and electrical contacts by slightly damping the tip do not soak with Isopropyl alcohol Safeguard Handpiece opening area metal keypad charging Plug and lens against liquid and sharp objects as this may cause electrical short circuit permanent optical damage or malfunction Optional Add ons FUSION is the most versatile LED light system that allows users to implement multiple functionalities from its advanced modular base kit In addition to Standard LED Light Head that comes with the kit wavelengths from 420 490nm optional add on functions can be achieved with Violet Light Head providing violet light 390 430 nm for a oral lesion cancer screening b curing of lower wavelength initiator adhesives e g TPO and c composite visualization removal Oral scr
2. DentLight Setting New Standards through Innovation x Q 8 FUSION INSTRUCTIONS FOR USE LED Curing Light System Rev 3 Powered by Patented Focus Beam Technology Product Information Description and Indications for Use Fusion Curing light System Rev 3 is a high power curing light device for polymerization of light cured materials by dental professionals It cures the wavelength range of 420 490 nm with the option to go down to 390nm These operating instructions provide recommendations and guidelines for the intended use of the light Please read carefully System Components gas oe FUSION Curing Light System consists A of Handpiece Charging Stand Curing iii ER Caps Power Adapter Light Shield ame os oie Barrier Sleeves Stand Stick Pad and Instructions for Use apes Quantity Description omen Main Control LCD Curing Caps 3mm 9mm 13mm each Power Adapter Light shield Barrier Sleeves 1 pack of 100 Stand Stick Pad Instructions for Use Battery Assembly l MOUSE Barrier Sleeves Country Blade Power Adapter Charging Stand i Plug Receptor DC Power Plu 3 Stand Stick Pad Product Safety Warnings and Cautions KJ Prior to installation and activation of the light please read these instructions carefully and follow safety procedures as well as the specific safety comments and recommendations presented throughout the instruction
3. N OFF Key anytime to stop POWER MODE High Power Half Power Metal Keypad MODE Digital Ti oa peas BATTERY BARS tataa Press POWER Key during count down Built in Self Protection ON OFF CHARGE h INDICATOR MENU FUSION has built in self protection on overheats and low battery Low battery is indicated with low Battery Bars one or no bars Low battery triggers one beep warning before self protection shutdown Light then goes to sleep mode Overheating is indicated with a flashing Thermometer Symbol and an audible warning beep Light shuts off when Overheat is triggered Replace battery Thermometer Curing Recommendation Symbol For specific resin sealants and bonding materials perform a timed curing test outside the mouth using a 3mm washer or hardness disk Cure from the top for the recommended time and reverse the disk Using a sharp instrument compare the hardness of the disk to the hardness of the composite it should feel exactly the same if well cured For general guidance use recommended curing times below For reduced heat or shrinkage use Half Power Mode while doubling the recommended curing times below Recommended Cure Times seconds High Power Mode Manufacturer Ivoclar Dentsply Resin Brand Filtek Supreme Plus TPH3 Color Shade A3E C 6D A3 A2 A3 DY 5 5 10 10 Final layer XRV Herculite Times Battery Care Keep FUSION charged at all times when
4. eening enables early LED Light Head 420 490nm Wavelength Violet Light Head 390 430nm transillumination best used with Tacking Exam tip for detection of dental caries cracks and location of root canal Product Specification Type of information Specifications cancer detection using fluorescence generated from tissue and viewed through Fluorescence Viewer that comes with FUSION to DOE starter kit Make sure to position the light 1 3 White Light Head 5000 6500K Light Intensity LED Light Head High Power Mode 2700 Half Power Mode 2700 peak 1300 average inch distance away from tissue in exam White Light Head offering an exam probe light that outputs super high power O 20 Violet Light Head 1000 at light tip mW cm2 or lux White Light Head High Power Mode 110 000 lux with Exam Tip Power Adapter Input 100 240V 50 60Hz Output 5V DC Battery performance Total light exposure time 35 45 minutes High Power 90 minutes full recharging time Operation Continuous operation patient application curing duty cycle 10 sec High Power Mode 20sec Half Power Mode ON 1minute OFF exam place 1inch away from soft tissue 60sec Pulse Power Mode ON 1 minute OFF Shutoff Timer auto shutoff User shut off anytime by pressing ON OFF Key Low battery auto shutoff Overheat auto shutoff Self protection shutoff is accompanied by warning backlight and audible beep as well as flashing THERMOMETER o
5. nge or high speed vacuum tip 3 Adjust to Half Power Mode 4 Adjust curing distance Battery will not 1 Broken pins in Charging Stand 1 Bypass replace or service Charging Stand charge 2 Electronic defect in Battery 2 Replace or service Battery Assembly Reorder and Optional Item Codes PN Description CL PN Description _ 7500080 08X FUSION Curing Light Kit X color code 7500060X LED Light Head X color code 7500082 Barrier Sleeves 100 pack 7500060U Violet Light Head 7500081 Curing Caps 9mm 50 pack 7500060W White Light Head 7500081B Curing Caps 13mm 50 pack 7500093 Lens Module Focus 7500092 Light Shield 7700012 FUSION DOE Kit X blank Silver B Blue P Pink G Gold Y US EU AU Australia DentLight Inc pas 1825 Summit Ave 210 Plano TX 75074 US Tel 800 763 6901 Outside US 1 972 889 8857 www dentlight com FUSION is a trademark owned by DentLight 2013 DentLight C Emergo Group Molenstraat 15 ENERGO EUROPE 2513 BH The Hague Netherlands Tel 31 0 70 345 8570 Fax 31 0 70 346 7299 Made in U S A 8 2013 v3 0
6. not in use Connect DC Power Plug to Plug Receptor on the Charging Base Place Handpiece onto Charging Stand Secure Charging Stand on a table counter with Stand Stick Pad for ease of L operation Alternatively connect DC Power Plug directly to CY Or 530 the back end of Handpiece to charge and power on the l unit DC Power Plug FUSION ee Mu Charge Indicator lights green while charging and turns off when fully charged Battery Bar displays three full bars when the battery is fully charged In normal operation Battery Bar drops from three to two bars while running and returns to full bar upon completion of a cycle Techniques Lens Module Flat Edge Lens Module Use disposable barrier sleeves and curing caps to protect lenses from liquid and composite damages Replace lens module immediately if it a has cured resin b is scratched or cloudy Align and lock flat edge of Lens Tool optional accessary to flat edge of Lens Module Turn Lens Tool counter clockwise and unscrew Lens Module Clean mounting thread Replace damaged lens with a new Lens Module by reversing the step Barrier Sleeves Slide sleeve into Handpiece Twist body relative to sleeve for tight fit Light Shield Slide in Light Shield from the LED Light Head to the Handpiece in a proper position for best access Tacking Ti Tip Size Tip and beam size can be adjusted by selecting the proper size Curing Caps For sP small cavity treatment snap on
7. or Licensed Dental Professional Use Only Operations Assemble Handpiece Upon receiving your FUSION remove all components from the package and examine them If damage is apparent please contact your authorized DentLight distributor from whom your light was purchased OL IOO Pl SON ee i Attach the Battery Assembly to the Main Control by screwing the Battery Assembly clockwise into the Main Control A short beep upon connection indicates that the light is battery powered and the LCD display should automatically power on Adjust the 360 swivel LED Light Head to a comfortable curing position and ensure good connection with the Main Control Light is now ready for use Operation and Setting FUSION uses advanced Metal Keypad and LCD interface ON OFF Key starts and stops the light MENU M Key sets the operation Time POWER Key sets the Power Mode FUSION defaults in High Power Mode Press M Key to select a Digital Timer Press POWER Key during countdown to change power to Half Power Mode and vice versa Press and hold Power Key to go to sleep mode High Power Mode allows the fastest curing with plasma like energy dosage Half Power Mode maintains the peak power and generates the minimum heat by lowering the average power in half with a 50 50 on and off duty cycle Built in settings are shown in the table below After starting Digital Timer counts down and the light makes an audible beep every 5 seconds Press O
8. pare parts and accessories than from the manufacturer such as incorrect power adapter Other acts which are not the faults of DentLight For service call 1 800 763 6901 in US to obtain RMA number Fill out RMA form online carriage paid and return as instructed in the RMA form to DentLight In case of a warranty claim the complete apparatus must be returned Alternatively contact your dealer for service handling and return Troubleshooting Guide Error Indication Possible Solutions Light will not 1 LCD is blank turn on 2 Buzzing noise when charging Light does not stay on for desired time 1 One or no Battery Bars 2 Bad connection or contacts Light generates too much heat Patient feeling discomfort 1 Press and hold Power Key 2 Charge Battery Assembly directly alone disconnect from Main Control and a bypass Charging Stand LUVAN i m overnight DC Power Plug Handpiece is overheated LED Light Direct an air stream from an air syringe or high speed Head gets hot vacuun tip to the light tip or wait for cool down 1 Key is not working Contact manufacturer or your local dealer for service 2 Timer counts down but no light 1 Charge Handpiece directly bypass Charging Stand for 1 hour 2 Check connection pins to make sure that they are not damaged If problems persist contact your dealer or Manufacturer for Service 1 Cure 10 seconds per layer 2 Direct an air stream from an air syri
9. r BATTERY BAR symbols EMC Compliance IEC 60601 1 2 Protection from Electric shock Type BF Protection from ingress of liquids IPXO Operating environment Ambient temperature 50F to 86F 10 C to 30 C Relative humidity 10 80 non condensing Atmospheric pressure 0 5 atm to 1 0 atm 500hPa 1060hPa Storage environment Ambient temperature 14F to 104F 10 C to 40 C Relative humidity 10 80 non condensing Atmospheric pressure 0 5 atm to 1 0 atm 500hPa 1060hPa Measured absolute irradiance using calibrated optical spectrometer Limited Two Year WARRANTY Register your FUSION curing light at htto www dentlight com DentLight Inc extends a two year warranty against defects in material and workmanship to the original purchaser of this product from an Authorized dealer except the Battery Assembly and Charging Stand one year warranty This warranty is valid providing factory inspection indicates that any such defect was developed during normal and proper use DentLight shall under no circumstances be liable for incidental special consequential damages and damage from misuse including the following expressed or implied Improper operation accident or neglect misuse or abuse such as physical damage dents scratches etc Liquid water rain extreme humidity ultrasonic autoclaving Tampering improper repairs or modifications that have not been carried out by a certified Service Center Use of other s
10. s for use The manufacturer accepts no liability for any damage resulting from the improper use of this unit and or any purpose other than those covered by these instructions 1 A CAUTION FUSION produces high intensity light Prolonged exposure to the skin oral mucosa or pulp can result in irritation or injury Do not place light in direct contact with unprotected gingival oral mucous membrane or skin Do not place light directly on the same tooth segment for more than 10 seconds in High Power Mode If long exposure cannot be avoided direct a stream of air over the tooth surface from an air syringe or high speed vacuum tip adjust to Half Power Mode or adjust curing distance 2 A CAUTION Do not look directly at light emitted from the device Do not use FUSION without suitable eye protection for the operator assistant and patient Use Light Shield Protective Goggle and or Curing Cap Exposure must be restricted to the area of the oral cavity in which the clinical treatment is intended 3 A CAUTION FUSION must be used with Single Use barrier sleeves to avoid cross contamination Replace barrier sleeve after each patient treatment is completed This sleeve also prevents composite material from adhering to the surface of the lens and degrading the curing performance 4 Products marked Single Use on the labeling are intended for single use only Discard properly after each use 5 DO NOT operate the unit in the proximit
11. y of flammable mixtures FUSION is not suitable for uses in the presence of a flammable anesthetic mixture with air or nitrous oxide Use in well ventilated area 6 Keep solvents flammable liquids and sources of intense heat away from FUSION as they may damage internal and external parts the seals or the buttons on the control panel 7 DO NOT autoclave or immerse unit in any kind of ultrasonic bath disinfectant cleaning solution or any kind of liquid Do not spray liquids directly onto the light and prevent liquids from entering FUSION open area such like Keypad Charging Stand and its connectors as this may damage or short circuit the device and can cause potential hazard for operator and or patient Glossary of Symbols A number of symbols are used on the device accessories and throughout this manual it is important that the user operator of FUSION understand the meaning of each symbol to avoid possible injury to the operator or and patient Please read before using this device Symbol is used to alert you to potential personal injuries and hazard Understand all safety messages that follow this symbol to avoid injury to the operator and or patient A Type BF Applied Medical Equipment Waste Electrical and Electronics Equipment WEEE odo Manufacturer European Authorized Representative oM Date of Manufacturing Single Use Only g Temperature Limitation Atmospheric Pressure Limitation Humidity Limitation Keep Dry F

Download Pdf Manuals

image

Related Search

Related Contents

平成25年度模擬授業(出前授業)科目一覧 (教育学部)  Kondator 440-W618 mice  Télécharger la transcription de l`interview  manuale di istruzioni all'utilizzatore installazione – uso  commelle 10  Manuel d`utilisation Réveil parlant 1 alarme (réf. 311060)  AIR CONDITIONER (SPLIT TYPE)  BoConcept Monte L001 Assembly Instruction  Sistema de som subaquátivo  