Home
TR3301 Operation and Service Manual
Contents
1. ii Vending operation The seguence of vending operating is illustrated as below Insert a coin Product available Dispense tissue automatically Reject coin without beep Pick up tissue from the collector Reject coin with beep Over Note 1 When the machine is setting into the fact that multi coins are for only one pack of product please tell the customer that the machine will not return the coin to him even if he doesn t want to buy the product after inserting one coin and one pack of product will be dispensed out until the customer inserts enough coins 2 When the coin whose size is more than the specified one is inserted into the coin validator it will be jammed and please press the coin return button to get back the coin TR3301 Tissue Vending Machine Ei Maintenance This machine is operated by battery So the maintenance of the machine will focus on the battery because itis critical for the functionality of the machine Every time when adding tissues or collecting coins the machine should be checked by doing a few purchasing operations Another task should be done is the battery checking A low battery will cause the machine works un properly I Check battery The battery checking function has been integrated in the machine for convenient maintenance To check whether the battery low occurs the only task to do is pressing the battery test button on the control panel If the voltage is too low the LED ind
2. TR3301 Tissue Vending Machine User Manual Panda Vending Limited www pandavending com TR3301 Tissue Vending Machine E Preface Welcome to use our vending machine Before you install and operate this machine please read the manual carefully In order to make good use of superior performance of the machine we strongly recommend you install and maintain it strictly following the instruction of the manual And keep this manual for your future reference If you have any guestion about operation or service feel free to contact us TR3301 Tissue Vending Machine Contents Preface lt lt lt senvsesenaesasneanasnasnannaenannsa naer aasa sead DR DE RE RR RR ER DR RE RE RR RE Ee 1 Appearance and components EE EE 0270 2 Installation and operation sees see ete EE EE EE eee EE EE RE EER testes 3 Troubleshooting 9 Technical 11 TR3301 Tissue Vending Machine Im Appearance and components Ad panel Tissue storage columns Coin acceptor Coin storage Control PCB Under the cover Door lock Sellout sensor Motor Product collector Battery Dispensing mechanism Goods Pressing Board Front View Inside View at Battery low LED indicator Battery test button Power switch Counter Control Panel Note there is possibly the difference bet
3. er of the validating sensor Sample coin installed After the installation of the sample coin finished the coin acceptor should be tested with the true coins repetitiously Each time one piece of product will come out after inserting two pieces of 1 coins If the motor can act after inserting the coin each time it means that the sample coin has been installed properly and this machine is ready to use During the test if you find the coin acceptor always refuses the coins pls change another coin as a sample one TR3301 Tissue Vending Machine It is normal that a valid coin cannot be accepted occasionally But it indicates the sample coin is not installed properly if the coins are refused freguently In this situation adjust the sample coin s position appropriately to make sure it is on the central area of the sensor with its bottom clipping in the groove If it still doesn t work well try to change the pose of the sample coin push it on the left side closely or make its top leaning to the right side of the coin clipping groove of the sensor near the spring as the illustration followed Usually it is better to push the sample coin on left side for thick coins and leaning to the right side would be better for thin coins ae Coin validating sensor Coin validating sensor Coin sample 4 4 Sample of thick coin Sample of thin coin Front view Side view II Operating the machine Before using the machine please check whethe
4. icator beside the button will keep lighting when the button being pressed it means the battery should be recharged If LED just flashes once or keeps dark when the button is pressed down it means the voltage is normal Notes a Technical parameters Capacity 12V 1 2AH Voltage when full 13 2V Voltage when receiving a recharging prompt from the system 12 5V Voltage when the system cannot start lt 12 2V b Please use the charger equipped by the machine manufacturer or the similar one to recharge the battery When it is full you have to powder off the charger to avoid over recharge the battery c Please recharge the battery before using the machine or when talking it out to use from the stock because the stored battery often discharges automatically d The battery should stand rightly not upside down or on the side e Ifthe system cannot start please check whether the battery works normally ll Recharge battery The machine uses a 12V rechargeable storage battery So a charger that is specially designed for 12V storage battery should be used to recharge the battery The chargers with three phases recharging control are strongly recommended for assuring the recharging safety and battery lifetime This kind of charger products can be found easily from the market TR3301 Tissue Vending Machine z Troubleshooting Some additional information useful for the troubleshooting is given firstly for your reference in follovving pictures Set
5. ix nuts on the rear of the door Unload the transparent Ad pressing plate Put on the ad Paper and use the plate to tightly press the Ad paper on the front surface of the door Fasten the six bolts back Size of Ad paper 520mm long and 270mm wide TR3301 Tissue Vending Machine Installation holes on the back v Battery installation Note When leaving the factory the anode and cathode of the battery will not be connected Before installing the battery it must be recharged and checked whether it can work very well Cathod Anode Battery Position Bottom right corner inside the machine case Caution If the battery was not installed on right position and connected wrongly it could cause leaking that is dangerous and harmful to the machine and human vi TR3301 Tissue Vending Machine Sample Coin Installation This machine uses a comparative coin detector so a real coin that is the same as the coins you want the machine to accept must be installed on the coin detector before using When installing sample coin pull the sample coin holder upward and put the sample coin into the slot carefully Refer to the following illustration f Pull the sample coin holder upward The position of sample coin Installing sample coin Coin validating SENSOT a i E al Kd m E sdi Sample coin Should be on the cent
6. r all the parts are included and there are two keys three pieces of pressing boards except the whole machine The setting switch1 2 3 and 4 on PCB board are showed as the right picture When switch 1 is set to ON position it means during making a transaction one coin is for one pack when switch 2 is set to ON position it means two coins are for one pack the rest switch 3 and 4 are deduced by analogy i Add goods Each column in this machine is designed in a definite specification given by customers when ordering Please add the tissues with same size as which you gave us when you ordering the machine Adding wrong size of the tissues could cause unnecessary troubles To add tissues please remove the pressing boards in each column first then stack new tissue packs into the columns Be sure that the stack level of each column should be almost the same because the tissues in each column will be dispensed by turns The pressing boards should be put on the top of tissues in each column after the TR3301 Tissue Vending Machine tissues has been loaded in the columns Make sure the pressing board with long handle should be put on the column at right end lt is important for sellout detection Please refer to the following illustration pressing board with long handle for sellout detection Note In order to avoid the unnecessary trouble don t put some rugged damaged pack or worn tissue in the column
7. ting Svvitch ou EG hk Ie m fi ul f Ea Power Battery low indicator Motor Counter JE Motor Battery test sensor button Motor control sensor f Coin acceptor Corn in sensor Sellout sensor Motor assembly Connectors on PCB Coin in sensor Coin acceptor assembly 10 TR3301 Tissue Vending Machine Note Be sure dont put your hands tools or other things into the dispensing mechanism to avoid hurting you or damaging the machine 1 Battery plugs un plugged Put on the plugs Replace the battery with new 2 Battery is empty one or recharge the battery No response after turning on 3 Sellout sensor is wrong Replace the sensor 4 Connectors on the control PCB Firmly put the connectors on are loosed the right positions 5 PCB is wrong Replace PCB with new one Replace the motor with a new 1 The motor is wrong one 2 The connector on the PCB for Put on the connector firmly motor loosed l Replace the sensor with a new Dispensing mechanism 3 Motor control sensor is wrong one 4 Motor control sensor on wrong Adjust the sensor position and position or loosed fix it firmly 5 Battery low Recharge the battery 6 PCB is wrong Replace PCB with new one 1 Coin slot is jammed Get rid of the rarity 2 The connector on the PCB for l Put on the connector firmly coin acceptor loosed o l Replace the sensor with a new Coin accep
8. tor doesn t 3 Coin in sensor is wrong one work properly 4 Coin in sensor on wrong Adjust the sensor position position Replace the coin acceptor with 5 Coin acceptor is wrong new one 11 TR3301 Tissue Vending Machine N Technical Specifications H x 438mm W x 185mm Weight 20KG Ambient temperature _ 0 40 C 10 85 and humidity Pack dispensing speed Less than 3 seconds 6 decimal digits Thank you for your choosing our products again 2006 E BIZ2CHINA LIMITED All rights reserved 12
9. ween the pictures and the practres and the real machine and the appearance is as per the real machine please TR3301 Tissue Vending Machine N Installation and operation Note In order to use this machine safely ensure its good operation and better being maintained be sure to carefully read and strictly follow the manual before the installation and use of this machine Installation 0 LI LI LI LLL Caution The machine should be installed firmly on solid wall The machine shouldn t be installed in the wet or dusty area The machine should be installed near the lamp house so that it can be used at night Tools 8 materials needed Electrical drill with a drilling bit diameter 12mm for drilling holes on the wall Four bulgy screws M8 or similar size Sleeve wrench suitable for M8 nuts or similar size nuts Cross screvvdriver Mount the machine Choose a vvall vvith flat surface vvhich can bear the vveight of the machine Drill four holes on the wall at an appropriate height the height should be suitable for easy operating of the machine distances betvveen the holes refer to the picture follovved on next page Insert bulgy screws into the holes Put the machine on the buloy screvvs through the holes on the back of the metal case of the machine Put on the gaskets and nuts then fasten the nuts of the bulgy screvvs Check whether the machine has been mounted firmly Ad Paper installation Remove s