1. Bariatu Ranchi 834009 Jharkhand General Terms amp Conditions The terms and conditions mentioned in tender notice no 3422 dated 02 06 2015 2 The tender should be submitted in duplicate complete with specification literature leaflet along with catalogues etc leaving no room for back references 3 Bids are to be submitted in two parts viz A Technical Bid containing complete technical aspects including original EMD Affidavit etc except price bid amp B Price Bid containing price elements only 4 Technical Specification should be in the proforma format given below A Technical Specification Proforma Sl Name of equipment amp Tenderer s detail Remarks or any other No Required technical technical extra advantaves of specification as mentioned in specification of the the quoted model or tender form equipment for which attachments if any they are quoting B Tenderers Technical Details of turn key works i Civil Electrical Mechanical furnishing etc works to be done if any by the bidders under turnkey project SI Tenderer s detailed item list work list Quantity offered by the No tenderer ii Electrical works If any required under turnkey SI Tenderer s detailed item list work list Quantity offered by the No tenderer Note 1 All the electrical items including Air conditioning amp earthing wil
2. Tubing should be made up of good quality rubber heat resistant 10 Wiring of the equipment should be enclosed in case 11 It should have deconcentrator a bleeder device on the evaporation that constantly removes a part of the boiling water from it so that the cumulative concentration of non volatile impurities in the water is prevented c Consummable items xvii GP point xviii Endo irrigation solution HYPO i Cottan ii Gauge iii Disposable syringe iv Local anesthesia solution v Suture vi Base plate vii Modeling wax viii Type 1 and 2 Impression compound ix Composite ponding agent etch polising kit x Silver Amalgam xi GIC Type 1 2 9 xii Zinc oxide cement and Eugenol xiii Zinc Phosphate Cement xiv Articulating Paper xv Endo file xvi Protaper xix Root canal sealers xx Calcium hydroxide power amp paste xxi Dental plaster xxii Dental stone Page 52 of 55 xxiii Die Stone xxiv Endodontic post Impression compound XXV Zinc oxide eugenol paste xxvi Rubber Dam Pedo and Adult xxvii Perio splint fibre xxviii Plaque stainer Xxix Bone graft allo amp Xeno granules power blocks XXX GTR membrane resorbable amp non resorbable xxxi Tac pins kit xxxiii Local drug delivery xxXiV Abgel XXXV Orthodontic Brackets Bands wires Tubes for edgewise and begg XXXVi Lingual sheaths xxxvii Lingual Cleats xxxviii Lingual Buttons XXXiXx Orthodontic Elastics
3. XXXX E Chains XXXXi Open Coil and Close coil spring xxxii Titenium mesh 10 psc 209 Hand instruments 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Mouth mirror Probe Explorer Tweezers Bur box Spoon excavator small amp large Condenser Diamond carver Hollen back Cement carrier Ball burnisher Mixing spatula metal and plastic Plastic filling instrument Composite filling instruments Ivory retainer Toffle meir retainer and band Extraction forceps adult and pediatric Warwick jems elevator Coupland Apexo elevator Bone rongeurs Bone file Suture cutting scissor Sickle scaler William probe Probe CPITNAWHO niddle holder Surgical instrument tray Page 53 of 55 29 Surgical kidney tray 30 Instrument trolly Rubber bowl amp Spatula Matrix band amp retainer 32 Mylar strip 33 Wax spatula 34 Wax carver 35 Wax knife 36 Lacreon carver 37 Morter amp pestle 38 Impression tray all types i e dentulous edentulous plain perforated all sizes 39 Denture trimming burs 40 Carbide burs Diamond burs 42 Dental die stone 43 Makintosh sheath 210 B P INSTRUMENTS STAND MODEL ADJUSTABLE TYPE e Heavy duty stand e Reliable occurate calibrated e High quality component e Velcro cuff e Metallic silver coated e Acastors wheel 21
4. amp installation of Dental Chair and other dental equipments on turnkey basis in newly constructed Dental Institute building at RIMS Ranchi Jharkhand India Tenders will not be accepted by hand or any other agency A Important dates for Tenders 1 Pre bid meeting for discussion on On 12 06 2015 at 12 30 P M in RIMS administrative conference various technical issues hall All the intending bidders must attend the pre bid discussion meeting for clarification of their queries amp requirements of RIMS No claims will be considered after finalization of tender paper Bidders may visit rims website for sample tender papers for pre bid discussion 2 Date of issue of tender From 19 06 2015 to 17 07 2015 The intended bidders may documents purchase tender document on any working day upon payment of Rs 5000 Rupee Five Thousand only in cash to the RIMS Cashier or they may download the document from RIMS website and enclose the tender cost in form of DD in the name of Director RIMS Ranchi with their tender document 3 Last date of submission of sealed on 20 07 2015 till 04 30 P M At RIMS Ranchi tender documents Only by speed post Registered post 4 Opening of technical bid amp On 21 07 2015 at 12 30 P M in RIMS administrative conference discussion on technical issues hall in front of purchase committee All the bidders or their duly authorized representative must represent the tender op
5. o Dental x ray machine is used for taking Intra Oral Periapical and Occlusal X ray e Operational Requirements o High resolution RVG based on CCD CMOS technology e Technical Specifications o Based on DC current o Tube voltage selection 60 65 70 kVp o Tube current 6 mA 8 Ma o Focal spot 0 8 x 0 8 mm o Total filtration gt 2 mm Al Page 28 of 55 o Minimum range of exposure time range 0 02 to 3 2 secs o Manufactured with International Safety standards for radiation leakage o Electronic selection of exposure time radiation according to tooth number It should be possible to select exposure time manually System Configuration Accessories spares and consumables o X ray unit should be supplied with lead apron thyroid collar and gonadal sheath o Should be supplied with lead partition Power Supply o Power input to be 220 240VAC 50Hz fitted with Indian plug o Servo Voltage stabilizer of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz Standards Safety and Training o Should be FDA approved product o Manufacturer Supplier should have ISO certification for quality standards o Electrical safety for dental x ray unit conforms to standards for electrical safety IEC 60601 IS 13450 Documentation o User Technical Maintenance manuals to be supplied in English o List of important spare parts and accessories with their part number and costing o Log book with instructions for daily weekly m
6. 60601 IS 13450 7 Documentation 7 1 User Technical Maintenance manuals to be supplied in English 7 2 List of important spare parts and accessories with their part number and costing 7 3 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out 17 Automatic Developer 18 Lead apron Zero Lead 19 Lead Collar Zero Lead 20 Lead Gonadal Protector Zero Lead 21 Lead gloves Zero Lead 22 Diagnostic kit 23 Biopsy kit 24 X Ray Hanger Page 34 of 55 Dental Patho Lab Items 25 Microscope i Binoculor Microscope Coaxial coarse fine knobs Tension adjustment Fine focus knob graduated stage movement XY direction on rack and pinion Quadruple revolving nosepiece with right hand mechanical stage Blue filter Dust cover Mirror unit Immesion oil power cord Halogen lamp Bioncular observation tube inclination 45 Diopter adjustment on the left ii Pentahead Microscope Multiobservation system for 5 persons fixed low stage nose piece focus 15mm focus stroke with coarse adjustment limit stop toque adjustment for coarse adjustement knobs high sensitivity fine focusing knobe adjustment built in illumination for transmitted light light intensitivity manager switch high colour reproductivity LED light source built in condenser with swing 26 Centrifuge 27 Microt
7. Endomotor 14 Light Cure 15 Panoromic X ray 16 70mA 110 KV High Frequency X ray 17 Automatic Developer 18 Lead Apron 19 Lead Collar 20 Lead gonodal protector 21 Lead gloves 22 Diagnostic kit set 23 Biopsy kit set 24 X ray hanger 25 Microscope i Binocular Microscrope ii Pentahead Microscope Page 15 of 55 26 Centrifuge 27 Microtome 28 Wax bath 29 Wather bath 30 Knife sharpner 31 Hot plate 32 Speser knife 33 Mobile Dental Van with all accesosires amp equipment specification details on page 58 to 67 34 Public Adress system 35 Demonsttration model for training 36 Scaler 37 Restorative instrument kit for amalgam and composite 38 Exteraction forceps 39 Rubber dam kit 40 RCT instrument kit 41 Bleaching unit 42 Magnifying loops 43 Elevators 44 Surgical micromotor 45 Instruments for Bone plating amp other major surgery i Oscilating saw with all attachments 46 Rows Maxillary disimpaction foreceps pair 47 Hyton William forceps forward amp downward traction 48 Harrison mandible holding with speed lock 49 Asch Nasal septum foreceps 50 Walsham nasal septum 51 Bone and plate holding 52 Reduction bone holding 53 Chin segment 54 Max
8. Universal Plier Bird beak 9 Tweed recktangular arch 10 Forming 11 Lingual arch 12 Small Artery OF SO Oe Page 43 of 55 158 159 160 161 162 163 164 165 i ii ii iv v vi 13 Dela rosa arch forming Grooved 14 Posterior band remover with pad 15 Debonding plier 16 Pliar with pad 17 Lingual bracket debonding 18 Distal end cutter 19 Pin and ligature cutter 20 Light wire cutter 21 Nance loop forming pliar 22 Rose torquing 23 Rose torquing pliar 0 016 0 018 24 Double end key 25 Ligature director 26 Direct bond bracket holder 27 Bracket holding twizzer 28 Lingual wire placement 29 Taurette for labial rectangle Arch forming 30 Taurette for lingual rectangle arch forming 31 Band pusher 32 Tucker Pliar rack space for hanging atleast 10 pliars Blue torch Base former Typodont Typodent articulator Welder Hydro solder Surgical instrument kit Periodontal Surgery Periodontal Probes William Naber Periodontal Chisels a Fedi 1 and 2 combined b Ochsenbein 1 and 2 combined Periodontal Hoe a Ochsenbein 4 b Rhodes 36 37 Scalers Page 44 of 55 a Sickle b Morse c Springfield d Jackquette e Nevi f Goldman g Cumine vii Surgical Curettes a Gracey Curette series Regular Mini Five After five b Universal Barnhart Columbia Mccall Langer Hutchinson viii Kramer Pricha
9. against him supplier Principal c That the firm is not supplying the same item at lower rate quoted in the tender to any government organization or any other institute Technical specifications with catalogue amp YesorNo On Page No dimensions of equipment accessories amp details of turnkey works The bidders have to provide complete layout plan of the constructions amp electrical works if any required and to be done by the bidder within their offer for installation amp functioning of the complete system I T return certificate amp balance sheet of the YesorNo On Page No bidders for last three financial year having minimum turnover of Rs 1 00 00 000 Rupee One Crore only in any one year within last three years Bidders acceptance letter undertaking that they YesorNo On Page No shall provide five years comprehensive warranty amp then after five years comprehensive maintenance contract with all spares accessories amp labour charges for all the equipments 10 ISO CE BIS FDA certificate in the name of YesorNo On PageNo equipment manufacturing company It must be shown in the certificate that this certificate is for particular product Note 1 Sales tax form JVAT 504 G Road permit Entry tax etc of Govt of Jharkhand will not be issued by authority It will be responsibility of the bidders to arrange JVAT form 504 G o
10. any one year within last three years Bidders acceptance letter undertaking that they shall provide five years comprehensive warranty amp then after five years comprehensive maintenance contract with all spares accessories amp labour charges for all the equipments Other terms amp conditions of tender 1 2 11 12 Technical part should contain the documents amp request for proposal and all such details as mentioned in the term of reference or tender paper Financial part should contain the financial bid inclusive of equipment accessories all admissible turnkey works warranty guarantee C M C taxes etc Details with respect to terms and conditions amp list of items and submission of such proposal can be obtained from Term of Reference i e tender document paper amp on RIMS website www rimsranchi org If required by the technical committee all the tenderers have to organize practical demonstrations of the same model machine at their nearest installation site to the nominated technical team of RIMS Ranchi on tenderer s own cost before finalization of technical evaluation report The undersigned reserves the right to accept or reject in part or as a whole any of the proposal received without assigning any reason thereof Any legal matter related to this tender shall be under jurisdiction of Hon ble Jharkhand High Court Ranchi Before participating the bid the bidders may visit the site at RIMS Ranch
11. bar left and right Wards periosteal elevators Bristow elevators Fan shaped Cryer elevator Cryer x bar elevator with T handle left and right Warwick james elevator Straight left and right Rowe zygomatic elevator Kilner zygomatic elevator Howarth elevator Coupland elevator 2 2 5 and 3mm Molt elevator Septum elevator Page 40 of 55 92 Alveolar dissector 93 Farabeuf Rugine 94 Root tip elevator double ended 95 Zyggomatic bone awl 96 Mandibula awl 97 Gillies skin hook 98 Harrison bone hook 99 Poswillo malar hook 100 Bone cutting single action amp double action straight and curved 101 Bone nibblers 102 Doynes rib shear 103 Rib cutter 104 Rib raspatory left and right 105 Fine chiseal 4 6 8 10 12 mm 106 Fine osteotome different size 4 7 9 12 mm 107 Nasal septum osteotome with guard 2 4 7 9 12 mm 108 Fine gouge 4 6 8 10 12 mm 109 Tessier osteotome 2 3 5 7 10 14 16 mm 110 Ramus striper left and right 111 Pterigoid chiseal 112 Volkman bone scoop 113 Read curettes 114 Lucas curettes 0 1 2 3 115 Kilner dott mouth gag with 3 blades 116 Davis boyle mouth gag 117 Ferguson mouth gag 118 Heister jaw opener 119 Plate bending 120 Plate cutter 121 Wire cutter 122 Arch bar 123 Screw driver 124 Self holding 125 Drill bits 1 9x70mm 105mm 115 mm amp 1 5x50x5mm 7mm 9mm amp 1 5x70mm 115mm 126 Screw holding x action 127
12. bmp jpg tif etc Windows 7 compatible With direct CD burn option An integrated program for diagnosis and communication with the patient Implant Bleaching amp Crown simulation feature Intra oral camera 1 Description of Function 1 1 Intra oral camera is required for documenting video and still images of intra oral procedures 2 Operational Requirements 2 1 High resolution Intra Oral camera based on CCD technology 3 Technical Specifications 3 9 Should give true image not a mirror image Light source integrated into handpiece Sealed design and hygienic material for proper disinfection The image live freeze save functions should be initiated by the station foot control Ergonomical shape of handle True imaging angle of 530 approx Viewing orientation 900 approx Magnification minimum 40X Resolution minimum 470 lines 3 1 0 Focal range min 6mm to infinity 3 11 Light source four output halogen 32 000 LUX at 10 mm Page 30 of 55 3 12 It should be supplied along with Desktop computer 20 inch screen Intel Pentium Quad Core 500 GB HDD RAM 4 GB DVD RW latest genuine windows version software and color laserjet printer 4 Power Supply 5 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 5 Standards Safety and Training 5 1 Should be FDA CE approved product 5 2 Manufacturer Supplier should have ISO certification for quality standards 6 Documentation 7
13. carbide or diamond tools should have rotation speed of 5000 rom should have smooth finish 206 H P grinder with suction 207 Phantom Head Simulators with Work Stations a PHANTOM HEAD TABLE O Phantom head table 45L x 29 W x 34 H should have two work stations diagonally opposite to each other There should be adequate space for the working of two students simultaneously Table top should be made up of stainless steel and havetwo drawers O Each work statim should be fitted with 0 O Control box for attachment ofMicromotor 3 way syringe and Airrotor with transparent water tank tubing for air rotor and foot control with nut fittings One Air rotor super torque hand piece and 2 spare cartridges per air otor handpiece with inimum of 6 months warranty from original manufacturer Micromoto 20 000 40 000 rpm 1 no Contra angle handpiece with Etype attachment 1 no Three wayair water syringe 1 no 0 O Manual controls for adjusting speedforward reverse motion hand foot control on off function 1 3c b DENTAL OPERATING LIGHT O Dental Operating light should have variable intensities of lux from 5000 to 40 000 It should be LED reflected light with antiglare protection shield c PHANTOM HEAD Phantom Head with mannequin body and pneumatic piston for all movements like tilting and rotation high quality ball amp socket neck joint for all
14. elevator double ended 95 Zyggomatic bone awl 96 Mandibula awl 97 Gillies skin hook 98 Harrison bone hook 99 Poswillo malar hook 100 Bone cutting single action amp double action 101 Bone nibblers 102 Doynes rib shear 103 Rib cutter 104 Rib raspatory 105 Fine chiseal different size 106 Fine osteotome different size 107 Nasal septum osteotome with guard 108 Fine gouge 109 Tessier osteotome 110 Ramus striper 111 Pterigoid chiseal 112 Volkman bone scoop 113 Read curettes 114 Lucas curettes 115 Kilner dott mouth gag with 3 blades 116 Davis boyle mouth gag 117 Ferguson mouth gag 118 Heister jaw opener 119 Plate bending 120 Plate cutter 121 Wire cutter 122 Arch bar 123 Screw driver 124 Self holding 125 Drill bits Page 18 of 55 126 Screw holding x action 127 Plate bender for recon plate 128 Reconstruction plates of different sizes 129 Different sizes amp shape of plates 130 Different dia amp length of screws 131 Skin graft blade Humby s knife with container 132 Gigli saw handle 133 Fickling dental mallet 134 Tongue depressor 135 Suction canula 136 Different size box for plate screw amp drill bits instruments 137 Sponge holder 138 Artery foreceps different sizes 139 suture cutting 140 All
15. movements of the neck and TMJ with provision to even fix TMJ in open position Phantom Headwith excellent quality face mask which can be easily retracted totally closed oral cavity drain nipple for drainage of water and container for waste water collection of 3 to 5 litres 1 set of articulator upper and lower jaw set with elastic removablegingival with articulator 2 sets of 32 gnathologically contoured ivory teeth with screws p d WORKING STOOL Page 51 of 55 O Should be a five wheel surgical stool with pneumatic piston for height adjustment seat and 208 PRE CLINICAL PROSTHETICS LABORATORY a Laboratory work station with 4 work place high quality stainless steel Each unit has e ONE Drawer Air Blower Bunsen Burner Illuminated Tube Light Micromotor 35 000 RPM with heavy duty Lab handpiece b Distilled Water plant 1 Quartz distiller Demountable boiler 2 Panel box and stand to accommodate regulator and electrical supply clamps etc 3 Quality of distillate pyrogen free PH 6 9 7 0 High purity low conductivity 4 Distilled water should be heavy metal salts pyrogen and iron free 5 Specific Conductivity at 25 deg C less than 0 4 X 10 6S cm Glass material or Chemical inert material 6 Equipment should be thermal shock proof 7 Gas vent should be there to remove volatile impurities leaving the condensate free from gaseous impurities 8 Automatic low water cut off 9
16. with quick disconnect coupling and light cure unit to be attached to the same coupling One 3way syringe with removable tip for sterilization All the controls of the chair should be touch pad on doctor s and assistant s sides The design should be such that it can be simply cleaned and disinfected to reduce the possibility of cross infection Autoclavable pad should be provided on the Unit where the hand pieces are placed Should have to reservoirs of water and disinfectant with automatic pressurization Should have a non retraction valve to avoid the reflux of contaminated materials Automatic hand pieces selection through sensitive pneumatic valves Should have warm water syringe Integrated 17 inches LCD TFT Monitor should be provided for RVG gt Spittoon Water Unit Specifications Removable porcelain bowl cup filler and spittoon nozzles which can be cleaned easily Water should get ON in the spittoon automatically as soon as the patient gets up for spitting Adjustable Timer up to 15 seconds should be there to adjust timings of the water flow in the spittoon One 3 way syringe should be there on the assistant side Should have Hi Lo suctions with easy reach filters The high suction should be powered through a motorized unit Swivell spittoon should be provided gt Operating Light Specifications With luminosity of 20000 lux and 25000 lux with 620 degrees of rotation of light arm movements Should get ON and OFF with No touch system f
17. 1 ECG MACHINE 12 CHANNEL o Compact in size easy and direct operation portable Accurate pace pulse identification and automatic analysis function Four working modes Manual Auto Physical Examination Storage 12 Leads simultaneous waveforms display 800 X 480 graphic 7 inch color screen with Alphabet keyboard for Input 215mm 12 channel format recording 215mm 12 channel format recording Built in USB RS232 interface ECGNET software optional Adapt to 110 230V 50 60Hz AC power supply Advanced Freeze function O Built in rechargeable Li ion battery 250 patients information storage Extendable USB interface allows net transmission USB flash disk and USB rinter connected High accuracy thermal printing adapt to 215mm roll paper and 210 X 140mm Z fold paper 212 Retractor Set Complete Klapp Volkmann Kocher Langenbeck 213 X RAY ILLUMINATOR VIEW BOX SIX PANEL Page 54 of 55 214 215 216 SS metal housing Uniformly illuminated by white fluorescent lamps Plexiglas plate and roller pin for easy film holding Power supply 220 volt A C main supply switch on front side Each viewing plane can be switch on separately Revolving Stool HI VACUUM SUCTION MACHINE Anand s High Vacuum Suction Unit India s First ISI Marked Suction Apparatus Housing Spot Welded Oven baked cabinet Also available with Stainless Steel Body Capacity 700 mm Hg 10 regulable flutter free vacuum control knob 45
18. 1 User Technical Maintenance manuals to be supplied in English 7 2 List of important spare parts and accessories with their part number and costing 7 3 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out 9 Pulp tester e It should be capable to tests pulp vitality of an injured non injured tooth e It should have three Preset speed mode high mid low speed e It should be easy to operate It should have specifically designed for patient comfort e It should be Convenient to operate e It should have Maximum stimulus 80 e It should have automatic off function after three minutes e It should be operated through 9 Volt long life high output batteries 10 Glass bead sterilizer Portable easy to handle with avery low current consumption variable from 150 250 deg C and temperature within 25 to 30 minutes and maintain uniformly as long as it is on Instruments may be kept only for 10 to 30 seconds and will be ready for use With High quality glass for retaining the temperature Minimum Unit power consumption for day long work On reaching 250 deg C indicator light will be on and the Unit will be ready 11 Amalgamator e It should have Digital display for pre dosed capsules e t should provide more safety economy amp quality to the amalgam preparation e t should have Modern
19. 29 Technical bids amp Price bids should be kept sealed separately superscribing the envelope Technical Bid amp Price Bid and Tender Notice No amp Tenderers name with full address amp telephone numbers Page 10 of 55 30 31 32 33 34 35 36 37 38 39 The tenderers shall give a clear and guaranteed delivery period for completion of supply amp installation After stipulated period of supply amp installation the luqiidated damage charges penalty for late job completion on the bidder will be i After 07 days one week from stipulated date of complete 0 5 point five percent per week of total contract value uptoto 04 weeks ii After 04 weeks 1 One percent of contract value per week upto 08 weeks iii After 08 weeks 2 0 Two pecent of contractr value per week upto 12 weks iv After 12 weeks the security money amp EMD will be forfeited by RIMS and the bidder will be debarred black listed for further participations Tenderers are required to answer all the question mentioned in the schedule amp should return the same duly signed and filled along with form A The tendering firms shall note that the supplies will be made in accordance with the specification mentioned in the tender Nevertheless the purchaser shall be liable for price variation after final approval by purchase committee The tenderer has to mention clearly the quality specification names
20. AA battery Endomotor It should be Brushless Endomotor with latest technology Wide LCD Display and simple control panel design It must have torque control from 0 8 to 6 5 Nem It must have auto reverse auto reverse then forward and auto reverse off function with sound indicator It should be suitable for Endo procedure It should be light weight for easy endodontic access and design to minimize fatigue and fingertip stress It should have way power source Battery or AC cord It should have option for foot control It should be micro processor Controlled with digital display It should have Speed range from 100 rpm to 13000 rpm depending upon different gear head It should have min 9 program storage in it It should have a start and stop button on its hand piece It should be compatible with 1 1 4 1 10 1 16 1 20 1 contra angles reduction hand pieces It should come with 20 1 reduction hand piece It should have brushless motor with on off switch on the motor It should be compatible with all standard rotary files Light cure 70 80 watt light source 60 deg Angle Probe or light guide with 1 pistol grip handpiece eye protection shield power source of 230v 115v Wave Length 450 500nm A short beep sound set at 10 sec or 5 sec Internal voltage regulation Minimum one year warranty extra bulb to be provided Page 32 of 55 15 Panoromic X ray It should be simple amp compact design in size It should have 3 po
21. Ltrs min Pump Type Double rotary vane pump Jars Wide mouthed 2 x 2 Ltrs Polycarbonate with self sealing bungs and mechanical over flow safety device Tubing 10 mm ID x 2 mtr PVC Vacuum Gauge Bourden type 10 cm Dia 0 760 mm Hg calibration Power 230 V 50 Hz 4 0 5 Amps 430 watts 110 V on request Noise Level 50 dB A 3 Almost whispers Dimension amp Weight 50 x 38 x 70 cms 40 Kg ONLINE UPS 10KVA Director Rajendra Institute of Medical Sciences Ranchi Page 55 of 55
22. Plate bender for recon plate 128 Reconstruction plates of different sizes Titanium Short Medium Large Straight Angled Page 41 of 55 129 Different sizes amp shape of plates Bone Plates Titanium Short Medium Large Straight Angled 130 131 132 133 134 135 136 137 138 Different dia amp length of screws Titanium Skin graft blade Humby s knife with container Gigli saw handle Fickling dental mallet Tongue depressor Suction canula Different size box for plate screw amp drill bits instruments Sponge holder Artery forceps FORCEPS PEAN DELICATE STR amp CVD 14 5CM amp 17 CM HAEMOSTATIC FORCEPS PEAN STR amp CVD 18 5 CM amp 12 5 CM 139 140 141 142 143 144 145 146 147 148 149 150 151 e o o o o mt ol N 153 Suture cutting Allies tissue holding Towel clips Needle holders Tooth amp non tooth tissue holding Adson dissecting forceps Wire twister Wire cutter Mini plate cutter Recon plate cutter Emergency drug tray Oxygen cylinder with mask DISTRACTION OSTEOGENESIS INSTRUMENT SET COMPLETE Laser soft tissue amp hard tissue It should be Digitally Pulse based Laser with pulse rate upto 0 5 KHz It should be Class 4 dental lasers It should have Wavelength of 810 nm It should have Max Pulse power output not less than 10 W It should have Repetition rate between CW to 0 5 KHz Finger Butt
23. RAJENDRA INSTITUTE OF MEDICAL SCIENCES RANCHI Tender paper for Machine amp Equipments for newly constructed Dental Institute at RIMS Ranchi Tender Notice No 3422 dated 02 06 2015 Issued to M s Against money receipt number 2 00seeeees RIMS dated 5068 Cashier RIMS Ranchi Page 1 of 55 Tender for supply amp installation of Machine amp Equipment of Dental Institute RIMS Ranchi To M s Dear Sir Director Rajendra Institute of Medical Sciences Ranchi invites you to tender for supply amp installation of machine amp equipment for Dental Institute at RIMS Ranchi The conditions of contract which will govern any contract made are as under Any special conditions attached in tender will also be part of the conditions If you are in a position to quote for supply amp installation in accordance with requirements stated in tender notice amp tender form you must also furnish all the information called for along with your tender This tender is non transferable All legal matter in respect to this tender will be subject to jurisdiction of Hon ble Jharkhand High Court Ranchi The last date of submission of tender paper by registered posts speed post only is 20 07 2015 latest by 4 30 p m Yours faithfully Sd Director Rajendra Institute of Medical Sciences Ranchi Page 2 of 55 OFFICE OF THE DIRECTOR RAJENDRA INSTITUTE OF MEDICAL SCIENCES RANCHI
24. al imaging of both panoramic and cephalometric x rays 2 Operational Requirements 2 1 System with Panaromic as well as Cephalometric X Ray is required with all the accessories 2 2 Should cater to all types of patients including adult pediatrics standing sitting and wheel chair patients Page 33 of 55 3 Technical Specifications 3 1 Based on DC current 3 2 Focal spot is 0 4 0 5 mm according to IEC 336 1993 specifications 3 3 Inherent filtration 2 5mm Al equivalent 3 4 Tube voltage min range 60 kV to 80 kV 3 5 Tube current min range 5 mA to 10 mA 3 6 Exposure time Panoramic 10 15 secs Cephalometric 0 5 20 secs 3 7 Pixel size 96 99 um 3 8 Image resolution 5 9 Ip mm 4 System Configuration Accessories spares and consumables 4 1 Standard Intel Quad core desktop with original windows software 4 GB RAM 500 GB hard disk 20 inch TFT monitor DVD RW and suitable film printer 4 2 X ray unit should be supplied with lead apron thyroid collar and gonadal sheath 5 Power Supply 5 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 5 2 Five KV Servo Voltage stabilizer of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz 6 Standards Safety and Training 6 1 Should be FDA approved product 6 2 Manufacturer Supplier should have ISO certification for quality standards 6 3 Electrical safety for dental x ray unit conforms to standards for electrical safety IEC
25. ations 1 Removable porcelain bowl cup filler and spittoon nozzles which can be cleaned easily 2 Water should get ON in the spittoon automatically as soon as the patient gets up for spitting 3 Adjustable Timer up to 15 seconds should be there to adjust timings of the water flow in the spittoon 4 One 3 way syringe should be there on the assistant side 5 Should have Hi Lo suctions with easy reach filters The high suction should be powered through a motorized unit 6 Swivell spittoon should be provided 3 4 Operating Light Specifications 1 With luminosity of 20000 lux and 25000 lux with 620 degrees of rotation of light arm movements 2 Should get ON and OFF with No touch system for maintaining proper sterilization while working 3 Color temperature of the light should be around 5000 Angstroms 4 Light should allow Vertical Horizontal and Axial amp Diagonal Movements for proper Focusing 3 5 Oil Free Air Compressor Medical Grade 1 It should have Air moisture filter 2 It should have Non retraction valve 3 It should have Pressure gage 4 It should have Air tank capacity of 30 40 Lt Page 22 of 55 5 It should have Auto cut off switch 6 It should give medical grade Air which is absolutely oil free Technical Features 1200 1500 R P M 230 Voltages 50 Hz 3 6 LED Light Cure Unit Modular Light Cure Unit Specifications e Advances in the power output of light emitting diodes LEDS have allowed a LED light cur
26. clave should be equipped with a powerful vacuum pump to eject air pockets from the chamber at the beginning and at the end of cycle Pre vacuum and Post vacuum Water purification unit based on reverse osmosis principle should be supplied along with the autoclave and it should be possible to connect the water purification unit directly to autoclave for continuous supply of high quality demineralized water It should have minimum four sterilization programs and two test program Programs should be monitored by microprocessor Chamber volume 22 25 liters Loading can be min 4 Kg instrument 1 Kg textile It should be class B autoclave so that hollow bodied instruments handpieces and turbines can be fully autoclaved 4 Environmental factors 4 1 Shall meet IEC 60601 1 2 2001 Or Equivalent BIS or EN61010 1 2 General Requirements of Safety for Electromagnetic Compatibility or should comply with 89 366 EEC EMC directive 5 Power Supply 5 1 Power input to be 220 240VAC 50Hz fitted with Indian plug Page 27 of 55 5 2 Servo Voltage stabilizer of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz 6 Standards Safety and Training 6 1 Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 6 2 Should be FDA CE approved product 7 Documentation 7 1 User Technical Maintenance manuals to be supplied in English 7 2 List of important spares and accessories with their pa
27. cument from RIMS for JVAT custom clearance duty exemption waiver relief in this regard 3 i Whether manufacturer or authorized dealer Yes orNo_ On Page No ii If authorized dealer then write names of the YesorNo_ On Page No original manufacturers and enclose the authorizations issued to you e g a Authorization letter of M s Yes orNo_ On Page No b Authorization letter of M s and so on Yes orNo_ On Page No 4 Income Tax PAN No e g XYZA1234G also YesorNo On Page No mention clearly that PAN No of proprietor or PAN no of Company 5 Demand Draft No dated issued by YesorNo On Page No name of bank _ amount Rs E E AEE in favour of Director RIMS Ranchi Earnest money in form of Demand Draft issued by any nationalized bank only amounting Rs 2 00 000 Rupee two lakhs only in favour of Director Rajendra Institute of Medical Sciences Ranchi Page 8 of 55 Affidavits through first class magistrate Notary YesorNo_ On Page No Public mentioning that a Our company has not been black listed or convicted in the past by any Hospital Organization or by any Government Semi government organization P S Us C B 1 C C amp free from all kind of litigation allegations b That the fim has no vigilance case CBI FEMA CCI case pending
28. cure system in few chairs then its price may be deducted from the orders or payments to the bidders Page 23 of 55 1 b Dental chair Advanced gt Description of Function The dental chair and unit is required for dental examination and surgery gt Operational Requirements The complete unit with dental chair and hand pieces is required Complete unit with Micro motor Air Rotor Air motor Ultrasonic Scalar Micro motor 3000 to 40 000 rpm range and Motorized suction gt Technical Specifications Dental Chair Specifications Fully motorized hydraulically self adjusting Chair with lifting capacity of 200 kgs Corrosion free construction and durable scratch resistant epoxy paint finish Should have seamless ultra thin upholstery to facilitate easy cleaning disinfecting Double articulating headrest for comfortable support Should have flip head rest to be used on patients on wheelchairs Footswitch with multifunction It should provide all chair movements adjustable and Programmable position movement of return to zero and emergency stop The hand rests should be fully adjustable and should rotate out of the way of the patient when he steps off Dental Unit Specifications Should be attached to the chair with overhead delivery system to accommodate up to following 4 modules One Turbine connections with hand piece One air motor connection with air motor and hand pieces straight amp contra One fiber optic air rotor connection
29. d diagonal adjustment 3 LED light 5000 K cool light or similar high quality light Page 26 of 55 4 Three position intensity with high medium and composite settings 1 F Doctor s stool 1 2 3 4 Cast metal alloy base with five tile castors Two way adjustable lumbar support Integral Gas cylinder for height adjustment Height range between 400 700 mm 1 G Assistant s stool 1 2 3 4 PO 2 Cast metal alloy base with five tile castors Height adjustable torso support with height adjustable foot ring Integral Gas cylinder for height adjustment Height range between 500 800 mm Certification US FDA CE European approved ISO approved Manufacturer should have ISO certification for quality standards Electrical safety conforms to standards for electrical safety IES 60601 1 Pedo chair Pedochair with miniature contra angle handpiesc and with above specifications of basic dental chair 3 Autoclave 1 Description of Function 1 1 Autoclaves are required for sterilizing instruments in high temperature and high pressure steam 2 Operational Requirements 2 1 Autoclave should be table top and front loading with fully automatic microprocessor based control 3 Technical Specifications 3 1 3 2 3 3 3 4 3 5 3 6 3 7 The autoclave should provide sterilization at 121 C and 134 C for both wrapped and unwrapped tools and also a flash cycle for rapid sterilization The auto
30. der with soldering attachment Power Supply 220V 50 HZ Max Current 20 A Transformer Heating Protection Capacity Regulator Spot Welding 1 30 Braze Welding 1 9 Heat Treatment 1 9 Dimension of weldment 0 2mm 1 8mm Fuse 5 20mm 20A 177 Lab micromotor Speed upto 40 000 RPM Long working without any heat One spare carbon brush set Low heat generation suitable for long use It should have Forward amp Reverse direction selection It should have Hand amp Foot Operation It should have Extra torque for smooth working 178 Steam cleaner should have Water level Safety device Should have Indicator light should have Electrical Cut Out should be provided with Steam Gun outlet should have additional Dry Vapor via Fixed Nozzle should have Efficiently leans tour denture with complete safety should have pressure guage should have Foot control for Electro Valve Should have Water Level Indicator 179 Dental lathe should have 1 2 HP motor should have 2800 RPM standard accessories included Page 47 of 55 180 Spindle grinder should have rotaiotn speed of 17500 rpm should have Eagle Brand High speed Drilling bit should be provided with heavy duty suction should have capable of cutting and polishing for various sized metal resin or plastic work should have Integrated Drilling Bit should have High Rotation Speed should have Fast Cutting and Grinding should have Low Noise 181 Burnout furnace should have Ceramic Fibre i
31. design with rounded edges made of resistant material e t should have Easy access control panel easy visualization of all the functions of the equipment e t should have the perfect homogeneity amp consistency of the amalgam mixture which is ensured by the elliptic movements e It should have an amplitude of 25 mm amp a frequency of 400 oscillations per minute e Incase of accidental opening the movement is automatically interrupted e It should have microprocessor for high precision and continuous selection time setting mode from 0 to 30 seconds Page 31 of 55 12 14 Apex locater It should Locate and calibrate Apex Automatically It should be able to measures root canal length in dry and wet conditions It should have Audible signal and meter for indicating the position of the apical constriction and file distance from apex It should work on multi frequency measuring software technology It should have a canal length indicator bars sound volume control off low high It should contain large LCD display with information display canal length indicator bars sound volume off low high battery power indicator meter bar for the ratio technique adjustable apical line Rating DC 4 5 V Power Consumption 0 135 VA Size W 105x D 105x H 115mm It should have weight not more than 185 grm It should contain all accessories ie 1 probe cord 3 file holders 3 lip hook 1 canal length tester 1 extension cord 4 1 5 V A
32. dian Rs INR B Essential accessories supplied by the firm free of cost with main machine to run the machine smoothly Sl Name of Technical Quantity Remarks if any No accessories specification in details with manufacturer name Page 4 of 55 C Optional accessories if any for major equipments Sl Name of Detail Qty Unit Mention Price FOR No accessories technical price clearly the Destination specification in excise duty with with make amp India charges or installation model Rs any other charges charges training to sales tax etc staff on turn in Indian Rs key basis with all taxes D Essential consumables required to run the machine such as papers cartridges chemicals etc supplied by the firm free of cost with main machine to run the machine smoothly The bidders must mention clearly the item wise rates for consumables amp also they should mention that how much quantity of consumables they shall supply free of cost the time of installation for first time practical demonstration of the machine Sl Name of Technical Quantity Unit Rate Remarks if No consumables specification in any details with manufacturer name E Rate for essential civil electrical works amp furnitures for smooth running amp installation of the machine Tenderers have to give detai
33. enance manuals to be supplied in English 8 2 Certificate of calibration and inspection 8 3 List of important spare parts and accessories with their part number and costing 8 4 Log book with instruction for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out 37 Restorative instrument kit for amalgam and composite 38 Extraction foreceps Forceps should have precise anatomically designed beaks for a sure effective grip Forceps should have optimum rockwell hardness for unmatched tensile strength Forceps should have maximum lifetime warranty against defects in material and workmanship O Full Set of Forceps for extractions of all the teeth including the impacted tooth The Forceps should be US FDA European CE approved 39 Rubber dam Kit 40 RCT instrument kit 41 Bleachig unit It should be easy to adjust at any angel position It should have 6 piece high power LED e It should have 1 30 min adjustable timer It should have wide LED screen e Wavelength should be 420nm 490 nm It should have 3 intensities Max gt 6000 mW cm2 e Input power should be 100 240V AC 50 60 Hz 42 Magnifying loops e It should have the widest field of view and longest depth of focus Page 37 of 55 43 It should be excellent clear view and great optical capability to provide the operator with the o
34. ening for discussion amp queries of purchase committee Note 1 For details of tender terms conditions amp specification please visit RIMS website www rimsranchi org from 05 06 2015 for sample tender paper to attend the pre bid meeting 2 Final Tender paper will be uploaded on 19 06 2015 All the bidders have to submit their tender as per final tender paper 3 Before participating the meetings the bidders may physically visit the site and they may discuss with H O D Dental Surgery RIMS Ranchi regarding requirements or queries B In case of lack of any essential required documents the tenders will be rejected The list of essential required documents which must be submitted with technical bid of the bidders i Photocopy of JVAT Sales tax Registration certificate in Jharkhand State ii Photocopy of JVAT Sates tax clearance certificate of Jharkhand State valid at the time of opening of technical bid OR If the bidding agency is not registered under Jharkhand sales tax department then they must give an undertaking through notary affidavit that They will supply the equipment items at RIMS Ranchi after payment of JVAT Jharkhand Sales tax on their own amp they will make their own arrangements for custom clearance in case of imported equipments They shall not demand any document from RIMS for JVAT custom clearance duty exemption waiver relief in this regard iii Manufacturing certificate or original copy of aut
35. ff according to demand 20 L tank capacity with air output 60 70L min oo0o0o Compact and should have wheels for easy movement 191 Dewaxing unit should have Stainless steel body should have Electronic controlled temperature should have capacity to hold 8 10 flasks should have facility to change water easily should be capable of maintaining required temperature should work on 230 V AC mains 192 Curing unit 193 Pre heating furnace should have High Theral yield Page 49 of 55 should have Reduced energy consumption should have Modular electronic valve should have Protection against corrosion electrogalvanized steel should have Monobloc cast ceramic muffle should have 50 program 194 Microsurveyor Dimensions Length 100m m X width 80m m X Height 200 m m to Length 120m m X width 110m m X Height 250 m m Weight 350 gms To 500 gms should have compact design and portability should be useful for patient consultation and explanation of treatment Should have freely adjustable points and easily readable scale lines should come with all the attachments 195 Acryliser should have Stainless steel body should have Electronic controlled temperature should have capacity to hold 8 10 flasks should have facility to change water easily should be capable of maintaining required temperature should work on 230 V AC mains 196 Flask press 197 Hydraulic press Easy to use with sturdy Durable co
36. hine should have Higher Starting Torque Page 48 of 55 should have Closed Internal circuit cooling system should have Coolent level warning light should have Cover lock indicator should have Clear view of the alloy fusion process should have Touch button control panel should have Arm Positioning sensor should have Automatic weight balancing should have Automatic Coil Positioning Power consumption not more than 2000 w standard accessories included 188 Pindex system should have Porecision Laser Pinhole Drilling unit should have Accurate Drill Hole positioning system should have Easily adjusting working position for excellent result should have Zeiser type drill supplied 189 Circular saw should have Internal Suction system should have Dust Collector should have Halogen Lighting should have standard Model support should have 4800 rpm saw motor should have inbuilt electromagnet should have Dual Security 190 Pneumatic chisel Pneumatic chisel with compressor O Stainless steel body with automatic oil feeder and provision of controlling incision power by handpiece Air pressure maximum upto 5 6 bar O Air consumption 40 50 It min O Noise level should not exceed 78 dB A Should be provided with a compatible compressor having following features O 100 continuous operation possible Low noise levels between 50 60 dB A Moisture draining facility Compressor should have facility of automatic switch on and o
37. horization of original equipment manufacturer in the name of bidder for bidding on their behalf Photocopy or fax copy will not be valid iv I T PAN no of the bidder Page 13 of 55 V vi vii viii ix Earnest money in form of Demand Draft issued by any nationalized bank only amounting Rs 2 00 000 Rupees Two lakhs only in favour of Director Rajendra Institute of Medical Sciences Ranchi Affidavits through first class magistrate Notary Public mentioning that a Our company has not been black listed or convicted in the past by any Hospital Organization or by any Government Semi government organization P S Us C B 1 C C amp free from all kind of litigation allegations b That the firm has no vigilance case CBI FEMA CCI case pending against him supplier Principal c That the firm is not supplying the same item at lower rate quoted in the tender to any government organization or any other institute Technical specifications with catalogue amp dimensions of equipment accessories amp details of turnkey works The bidders have to provide complete layout plan of the constructions amp electrical works if any required and to be done by the bidder within their offer for installation amp functioning of the complete system I T return certificate amp balance sheet of the bidders for last three financial year having minimum turnover of Rs 1 00 00 000 Rupee One crore only in
38. i and may have discussion with the concerned faculty H O Ds regarding their requirements amp queries Price Bid of only those bidders will be considered who will qualify the technical documents parts as well as technical specification parts For major equipment the bidders have to quote separate sealed price for each amp every equipment so that price of only specific technically qualified items of the bidders may be opened No payment shall be made in advance whatever circumstances may be The bidding prices will be valid at least for two years or the next tender which ever is earlier If there will be government holiday on any last day of the above schedule the tender process will continue on the just next working day Sd Director Rajendra Institute of Medical Sciences Ranchi Page 14 of 55 List of Machine amp Equipments for Newly constructed Dental Institute at RIMS Ranchi for tender notice no 3422 dated 02 06 2015 S No Name of Equipments 1 Dental Chair Unit a Electrically operated basic dental Chair b Advance Dental Chair c Dental operatory unit Cuspider e Operating light f Doctor s Stool g Assitant s stool Pedo Chair Autoclave Ultrasonic Cleaner Needle Burner Intra Oral X ray RVG ON ail o F o rhy Intra Oral camera 9 Pulp tester 10 Glass bead sterilizer 11 Amalgameter 12 Apex locator 13
39. ication for quality standards Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 Provision for Remote Diagnostics through RS 232C serial interface or equivalent gt Documentation User Technical Maintenance manuals to be supplied in English Certificate of calibration and inspection List of Equipments available for providing calibration and routine Preventive Maintenance Support As per manufacturer documentation in service technical manual List of important spare parts and accessories with their part number and costing Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out Note Equipment with 5 years warranty and thereafter 5 years CMC will be taken for the purpose of price evaluation The above Equipments are to be supplied with Suitable Compatible Cabinet Furniture Steel Modular make for safe custody of the Equipment Should confirm to all international safety standards turnkey installation and with warranty CMC as indicated and which shall be considered for the evaluation of the price bids 1 c Dental Operatory unit 1 Should be over head delivery system with minimum 5 delivery ports for various handpieces scaler and 6 way syringe It should have at least 2 fiber optic delivery ports It should have one in built Piezon LED fiber optic Ultrasonic Scaler freq
40. ies tissue holding 141 Towel clips 142 needle holders 143 tooth amp non tooth tissue holding 144 Adson dissecting forceps 145 Wire twister 146 Wire cutter 147 Mini plate cutter 148 Recon plate cutter 149 Emergency drug tray 150 O cylinder with mask 151 Distractor Set 152 Laser Soft tissue amp Hard tissue 153 Surgical motor with plyrio dispenser 154 Ultrasonic Fixation Set 155 Angled Screw Driver Angulus Set 156 Level One Fixation Set 157 Set of pliars 158 Pliar rack Page 19 of 55 159 Blue torch 160 Bone former 161 Typodant 162 Typodent articulator 163 Welder 164 Hydro solder 165 Surgical instrument kit for Periodontal Surgery 166 Articulator semiadjustable 167 Extra oral intra oral tracer 168 Hot water sterilizer 169 Geyser 170 Distill water apparatus LAB EQUIPMENTS 171 Plaster dispenser 172 Madel trimmer with carborandum disc 173 Madel trimmer with diamond disc 174 Pressure molding machine 175 Vibrator 176 Welder with soldering attachment 177 Lab micromotor 178 Steam cleaner 179 Dental lathe 180 Spindle grinder 181 Burnout furnance 182 Proclean furnace 183 Sand blasting machine 184 Vaccume mixture 185 Curing pressure pot 186 Induction casting machine 187 Casting machine 188 Pindex system 189 C
41. illary bone graft holding 55 Mandible bone graft holding 56 TMJ spreading foreceps 57 Czerney retractor 58 Double hook skin retractor 59 Mcindoe retractor Page 16 of 55 60 Rayne mandibulr retractor 61 Davis double ended retractor 62 Chin retractor 63 Forked ramus retractor 64 Channel retractor 65 Kilner retractor 66 Haejeck cheek retractor 67 Kilner nasal retractor 68 Kilner skin retractor double ended 69 Farabeuf retractor 70 Malleable copper retractor 71 Austin tissue retractor 72 Smith spreader retractor 73 Right angle Lengenback retractor small medium big 74 Condylar neck retractor 75 Brown lingual flap retractor 76 Volkman retractor 77 Rowe orbital floor retractor 78 Mcdonald dissector 79 Periosteal elevators 80 Dental elevators x bar 81 Wards periosteal elevators 82 Bristow elevators Fan shaped 83 Cryer elevator 84 Cryer x bar elevator with T handle pair 85 Warwick james elevator St Rt Lt 86 Rowe zygomatic elevator 87 Kilner zygomatic elevator 88 Howarth elevator 89 Coupland elevator 90 Molt elevator 91 Septum elevator 92 Alveolar dissector Page 17 of 55 93 Farabeuf Rugine 94 Root tip
42. illating Saw Should cut in a right angle Should have Maximum speed of 20000 cpm Maintenance free D C brush less motor Snap lock assembly and disassembly of all attachments Sterilizable through steam ETO and Flash papo Page 38 of 55 ii Micro Sagittal Saw Should cut in same horizontal plane a Should have Maximum speed of 25000 cpm b Maintenance free D C brush less motor c Snap lock assembly and disassembly of all attachments d Sterilizable through steam ETO and Flash Connecting cord a Should be 10ft long 3 8 diameter flexible electrical connecting cord b Dot to Dot type push pull connectors at both ends c Autoclavable a Electric Controller It should have a Should have touch screen display control for incorporating multifunction into systems b Should have interactive icons represents system components and functions c Outputs should represent in digital figures d Weight should be under 5 kg Supply 220 240V only 50 60Hz e Should be able to identify different hand pieces with display on console f Should have function of controlling brightness contrast and alarm volumes on the console g Torque sensing feedback capability h Should be programmable as per surgeon preference b Footswitch It should have a Should have fully programmable footswitch as user need b User should be able to control following functions via footswitch Forward Reverse Oscillation Switch over to high l
43. ing unit LCU with an 8 mm diameter light guide tip to achieve a similar depth of cure ina camphorquinone photo initiated composite as a halogen LCU e Blue LEDs can be used as photo detectors and may be of future use in dental radiometers e When assessing the output from an LCU it is not only important to know the spectrum and irradiance but also whether the emission is pulsed or continuous 3 7 Foot Control Single foot control for all instruments with variable speed control 3 8 Dental Stool Stable with 5 castor base with load stabilizing gas spring Backrest tilt should be adjustable 2 Nos One for Dental surgeon and one for Assistant 4 System Configuration Accessories spares and consumables 4 1 System as specified 4 2 All consumables required for installation and standardization of system to be given free of cost 5 Environmental factors 5 1 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 5 2 The unit shall be capable of operating continuously in ambient temperature of 10 40 deg C and relative humidity of 15 90 5 3 Complete installation of the system including water input and drainage system has to be installed 6 Power Supply 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 6 2 Voltage corrector stabilizer of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz 7 Standards Safety a
44. ions 3 1 Based on piezoelectric technology 3 2 Having torque tool for tightening of the tip 3 3 High power turbo mode and low power mode 3 4 Should have LED light in scaler handpiece 3 5 Automatic smart power feedback control 3 6 Minimum vibration frequency of 28 36 KHZ and 3 7 Ten tips for scaler one endodontic kit and one set of perio curette tips 3 8 Foot pedal 3 9 Separate control for water and tip vibration 3 10 Should be supplied with two autoclavable hand pieces 3 11 It should have self contained tank of 300 ml capacity 4 System Configuration Accessories spares and consumables 4 1 System as specified 5 Environmental factors Page 36 of 55 5 1 The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 5 2 The unit shall be capable of operating in ambient temperature of 20 30 deg C and relative humidity of less than 70 6 Power Supply 6 1 Power input to be 220 240VAC 50Hz fitted with Indian plug 6 2 Servo Voltage stabilizer of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz 7 Standards Safety and Training 7 1 Should comply with Medical Device class II type BF in conformity to the requisites of Directive 93 842 CEE for the SCALER unit 7 2 Should be FDA CE approved product 7 3 Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 8 Documentation 8 1 User Technical Maint
45. irular saw 190 Pneumatic chisel Page 20 of 55 191 Dewaxing unit 192 Curing unit 193 Pre heating furnace 194 Microsurveyor 195 Acryliser 196 Flask press 197 Hydraulic press 198 Mechnical press 199 Deflasking unit 200 Duplicator 201 Electrolyting polishing unit 202 Wax heater 203 Wax carver 204 Milling machine 205 Palatal trimmer 206 H P grinder with suction 207 Phantom head simulators with work station 208 Preclinical prosthetic laboratory 209 Hand instruments 210 B P Insturment 211 ECG machine 12 channel 212 Retractor Set 213 X ray view box 214 Revolving stool 215 Suction machine 216 Online UPS 10 KVA Page 21 of 55 1 Dental chair Basic amp advanced 1 a Basic Dental Chair Dental Chair and Unit 1 Description of Function 1 1 The dental chair and unit is required for dental examination and surgery 2 Operational Requirements 2 1 The complete unit with dental chair and hand pieces is required 2 2 Complete unit with Micro motor Air Rotor Air motor Ultrasonic Scalar Micro motor 3000 to 40 000 rpm range and Motorized suction 3 Technical Specifications 3 1 Dental Chair Specifications 1 Fully motorized hydraulically self adjusting Chair with lifting capacity of 200 kgs 2 Corrosion free construction and durable scratch resistan
46. l have to be supplied amp installed by the tenderer Page 3 of 55 iii Furnitures works If any required to run the machines under turnkey Sl Tenderer s item list Quantity offered by the No tenderer 1 Before quoting the tender amp before participating in the meeting the tenderers must have to visit the sites amp they have to discuss with authority for location amp confirmation of site 2 Before finalization of the tender if needed by technical committee the tenderers have to arrange on site practical demonstration of their quoted machines major equipment to the members of technical committee on any of their pre installed sites on tenderer s own cost 3 All the essential civil electrical plumbing air compressor furniture etc works other than existing is are to be done by the bidders for smooth amp uninterrupted installation amp functioning of the equipment Hence the bidders have to quote their bids accordingly Full signature of the tenderer with seal Designation 2s cssc2sdiveeeeusicce Dated rciecciccesiasaseeies Price Bid Proforma Price of every item must be in separate sealed envelops A Sl Technical Unit Price Mention clearly Price FOR destination No specification of in Indian the excise duty with installation the main machine Rs charges or any charges training to other charges staff Doctors on turn sales tax etc in key basis with all taxes In
47. l specifications of the relevant accessories which they will supply along with the main equipment free of cost in their price bid The price should be inclusive packing carriage amp installation cost The total cost of each equipments should be quoted in figures and words The price quoted should be valid for at least one year from the date of opening of tender The intending tenderers should produce the copy of manufacturing registration certificate In case of authorization original authorization certificate issued by the manufacturer in the name of Director RIMS Ranchi The authorization must be valid at the time of tender opening The tenderer must enclose registration certificate of Jharkhand Sales tax JVAT along with update respective clearance certificate or If the bidding agency is not registered under Jharkhand Sales tax department then they must give an undertaking through notary affidavit that They will supply amp install the equipment items at fixed destination after payment of JVAT Jharkhand Sales tax on their own amp they will make their own arrangements for customs clearance in case of imported equipments They shall not demand any document from Director RIMS for clearance or duty exemption waiver relief in this regard of submission of security money Rs 10 of the order value The tenderer should furnish the warranty guarantee period of the complete system The tender without EMD will be ignored straightway Incomp
48. lete tender will be summarily rejected Page 6 of 55 17 The EMD will be refunded in full to the unsuccessful tenderers after finalization of tender and in case of successful tender the EMD will be refunded only after expiry of warranty guarantee period 18 The full EMD shall be forfeited in case of backing out of the offer after acceptance 19 The successful tenderer have to supply the items in accordance with the specification as finalized and approved by the purchase committee Full signature of the tenderer With seal and date Designation 20 Contractor Form A Telegraph Address 2 2 s2020 ciee de eine delete vetetiwi ie ateeene adie aa Telephone No 0 0 00eeee ees Telex NO 2 sdsncxtieteeieeseonie gouged Fax NO eoon neies From Full name and address of the tenderer To The Director Rajendra Institute of Medical Sciences Ranchi Sir 1 We hereby offer to supply the stores detailed in the schedule here to such position thereof as you may specify in the supply order at the price given in the said schedule and agree to hold the order offer open till it is opened I We shall be bound by communication of acceptance within the prescribed time 2 We have understood the instructions to tenderers and terms conditions of contract for contract concluded by Director RIMS as contained in schedule amp tender notice We have thoroughly examined specification drawing or pattern quoted i
49. lowing information should be given in the offer by tenderers a Complete configuration of the main equipments b Relevant must accessories should be supplied with the equipment if it is required for running the complete system Optional accessories if any Any particular make consumable chemical to be used for functioning of the equipment If there will be provision of specific or locked consumable then the overage consumption quantity of consumables will be compared during price evaluation 25 Liquidated damages shall be levid for delay in supplies as per Governing Rules 26 Guarantee For Equipments All quotees firms shall confirm guarantee of the complete equipments for 5 years of trouble free working from real date of handover installation amp functioning They will undertake repairs if needed within 03 days of intimation They shall also indicate in their technical bids how many precautionary physical check up would be carried out by them during guarantee period 27 The successful tenderer shall have to submit security deposit equal to 10 of the value of the contract in form of Bank guarantee pledged to Director RIMS Ranchi 28 Tenders Quotations are to be submitted in duplicate Number of pages leaflets pamphlets catalogue drawings etc should be tied separately and marked original duplicate However the tender inquiry document issued by RIMS should be attached with original copy of tender quotation
50. ls of civil including furnitures amp electrical works to be done for smooth running of machine FAS cebotbcduatentosends det in words No words RS sosser peaini i paianed ionu dai with five years comprehensive guarantee warranty with all accessories spares manpower amp turnkey maintenance works Price of Comprehensive maintenance contract with all spares after expiry of guarantee period for five years Year C M C Rate in Indian Rs per year 1 Year 2 4 Year 3 Year 4 Year 5 Year Note 1 Price of C M C for five years will also be considered during price comparative evaluation Page 5 of 55 10 11 12 14 15 16 2 Warranty as well as CMC will cover inclusive of all spares accessories amp turnkey works and it will also cover i X ray amp C T tubes amp high tension cables ii Helium replacement iii Any kind of motor iv Plastic amp glass parts v All kind of sensors vi All kind of coils magnets probes transducers cuffs paddles cables chart recorders patient circuits tube bulbs electrodes humidifiers sensors cassettes printers amp images UPS including the replacement of batteries Air conditioners fuses transformers monitors cameras stabilizers furnitures aprons badges radiation accessories software amp Hardware chambers phantoms amp other accessories if any will be supplied amp installed by the bidders witho
51. ment 12ft x 2 ft gt It should have one in built Peizon LED fibre optic ultrasonic scaler frequency 28 36 KHz with 4 scaler tips and one set of periocurette tips gt Foot Control Single foot control for all chair movements and control for airmotor airroter ultrasonic scale Two intensity cold light halogen light rotable in 2 axis Should be supplied with 4 spare bulbs Should have LED based X ray viewer Should have LED based O P G viewer 17 inch Monitor original from the company should be provided for RVG System Configuration Accessories spares and consumables gt System as specified All consumables required for installation and standardization of system to be given free of cost gt Environmental factors The unit shall be capable of being stored continuously in ambient temperature of 0 50deg C and relative humidity of 15 90 The unit shall be capable of operating continuously in ambient temperature of 10 40 deg C and relative humidity of 15 90 Complete installation of the system including water input and drainage system has to be installed gt Power Supply Power input to be 220 240VAC 50Hz fitted with Indian plug Voltage corrector stabilizer of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz gt Standards Safety and Training Complete system should be FDA CE UL or BIS approved product Page 25 of 55 Manufacturer should have ISO certif
52. n the schedule here to and am are fully aware of the nature of the stores required 3 The following pages have been enclosed to and from part of this tender s technical bid Yours faithfully Signature of tenderer Page 7 of 55 21 All documents duly completed signed and sealed should be enclosed with tender offer failing which quotation will be treated as incomplete Technical compliance report duly filled and signed with seal of the bidder The bidders must fill all the rows columns of this compliance report This report will be inspected amp evaluated by purchase committee and accordingly documents will be verified on the concerned page numbers SI Enclosures required Have you If yes then on page No enclosed it no of this bid write clearly Yes or No 1 Photocopy of JVAT Sales tax Registration YesorNo Page No certificate in Jnarkhand State 2 Photocopy of JVAT Sates tax clearance certificate of Jharkhand State valid at the time of opening of technical bid OR Yes orNo_ Page No If the bidding agency is not registered under Jharkhand sales tax department then they must give an undertaking through notary affidavit that They will supply the equipment items at RIMS Ranchi after payment of JVAT Jharkhand Sales tax on their own amp they will make their own arrangements for custom clearance in case of imported equipments They shall not demand any do
53. nd Training 7 1 Complete system should be FDA approved product 7 2 Manufacturer should have ISO certification for quality standards 7 3 Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 7 4 Provision for Remote Diagnostics through RS 232C serial interface or equivalent 8 Documentation 8 1 User Technical Maintenance manuals to be supplied in English 8 2 Certificate of calibration and inspection 8 3 List of Equipments available for providing calibration and routine Preventive Maintenance Support As per manufacturer documentation in service technical manual 8 4 List of important spare parts and accessories with their part number and costing 8 5 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out User Technical Maintenance manuals to be supplied in English Certificate of calibration and inspection List of important spare parts handpieces and accessories with their part number and costing Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt outfect Note The bidders have also to quote the separate rates for i Scaler amp ii Light cure system in such a manner that if the institute does not require the scaler or light
54. ng with autoclavable sterilisable containers trays which meets international standards and approved for steam sterilisation procedures to EN 285 2006 A1 2008 and validated HCTP ISO 17665 part 1 2006 The sterilization containers should offer superior filtration efficiency of more than 99 and its preferable to have an indicator to show whether the instruments inside are sterile or unsterile e Sterilization container and instruments should be preferably of the same parent company The following Implants must be quoted with 20 nos each PINS Resorbable 2 1 x4 MM cc ccc PINS Resorbable 2 1 x5 MM RESORBABLE PLATE STRAIGHT 4 HOLE MEDIUNM RESORBABLE L PLATE LEFT 6 H LONG 4 RESORBABLE L PLATE RIGHT 6 H LONG 5 RESORBABLE ORBITAL PLATE 8 HOLE 000000e RESORBABLE PLATE STRAIGHT 8 HOLE RESORBABLE PLATE STRAIGHT 22 HOLEG RESORBABLE MESH PLATE 0 6 26X26MM 155 Angled Screw Driver Angulus Set with Complete accessories 156 Level One Fixation Set 1 0 1 5 2 0 complete set with all additional accessories 157 Set of pliars Orthodontics heat treated tips precise joint alignment smooth action in hand FDA approved SS contains 10 or more of chromium provide more resistence to corriosion 10 yr warranty 1 Weingart plier Hoe plier straight Loop forming plier Young loop bending plier Reynolds band countering Adams
55. nstruction Can accommodate up to three flasks Pressure of 400bar The oleo dynamic circuit is absolutely leak proof and no maintenance is required 198 Mechanical press 199 Deflasking unit Robust high performance chiesel operated by compressed air for universal use in the laboratory High frequency chisel to deflask dentures and disinvest casting Avoid micro cracks formed by unconventional methods of plaster removal High quality compress air control Filter Lubricator regulator unit in built in circuit Provided with 3 Tips 200 Duplicator should have Heating Homogenity Eliminating Overheating Risks should have 2 Possible Compounding Procedures Continous Intermittent should have 10 programs should have Rotaiton Speed 30 Ltr min should have Capacity of 6 kg Weight not more then 20 kg 201 Electrolyting polishing unit Application for non oxidizing dental alloys Provide surface with bright glossy and durable lusture 202 Wax heater 203 Wax carver Page 50 of 55 204 Milling machine should have Double Joint arm to support any Micro Motor should have Double Joint arm to support any Micro Motor should have Complete with Model Holder base should have Lifting device should have Stainless steel working plan should be suitable to carry out milling poerations should have Air option should have Revolving Light option 205 Palatal trimmer should have capable for Inside and Outside surfaces of plaster should have
56. nsulated should have made with Thick Mild Steel Sheet should have Heating eleent made of Kanthal wire should have Maximum Temperature of 1200 C should have Digital Display cum controller 182 Porcelean furnace should have 250 programme furnace should have Motorized Pressing system should have Pressing process under continuous vacuum should have 9 9 programmable pressing levels should have Single or Multi Points injection should have Possibility to press in large sized rings up to 8 cm of diameter should have 50 pressing programs 183 Sand blasting machine should have Two tanks for Micro amp Macro blasting should have Pressure Gauge should have Pneumatic Foot Control should have Air Filter should have inbuilt Water Air Filtering System should have Complete Elimination of Dust 184 Vacuume mixture should be capable for Bubble Free mixing of Investments and Stones under Vacuum should have internal suction should have Digital Timer for setting mixing time should have Accurate and constant vacuum mixing 185 Curing pressure pot 186 Induction Casting machine Should have Higher starting torque Closed circuit cooling system Coolent leveling warning light Cover lock indicator clear view to allow fusion process touch button control panel timed end of cycle shutdown of the cooling pump Auto stand by function when idle for 5 min Standard accessories included Power supply 230v 50 60 v 2500w 187 Casting mac
57. of companies for consumables like films amp others to be used in the machines for optimum quality results The tenderer has to assure in written about the local availability of consumables in their tender If the supplier having been called upon by the purchaser to furnish security deposit S D failed to furnish the same within the period provided it shall be lawful for the purchaser to forfeit the E M D and to cancel the contract The purchaser shall be entitled and it shall be lawful on his part to forfeit the amount of security deposit in whole or in part in the event of any default failure or neglect on the part of the supplier in the fulfillment of performance in all respect of the contract under references or any other contract with the purchaser or any part thereof to the satisfaction of the purchaser The security deposit shall remain in full force and effect during the period that would be taken for satisfactory performance and fullfitment of in all respects of the contract i e since final acceptance of the goods equipments or any other by the consignee and be valid upto guarantee period of the equipments to be purchased After complete installation of the equipment the supplier shall inform the technical committee or the concerned authority in writing for inspection amp functioning of the equipments If the inspecting officer finds that pre inspection of the consignment is not as required then the consignment is liable for rejec
58. ome 28 Wax bath 29 Water bath 30 Knife sharpner 31 Hot plate 32 Spenser knife 33 Mobile Dental van with accessories and equipments Sandwich panel body fibraction specifications including General Box body specification Electrical fittings specification Water system specification Equipment details OV GN E Miscellaneous A General Box body specification Sandwich panel body specification Interior body specification Floor specifications Roof specification Interior Partition wall specification Cabinet specification Doors amp windows specification a ES a Oe a Countertops specification Page 35 of 55 B Electrical Fittings Specification a Generator b c d lt Air Conditioning Exterior amp Internior Lighting pl jp ym ga Se Na TC Stabilizer amp Voltmeter with adepuate earthing C Water system specifications a Drinking water storage system b Waste water from Dental Units Collection System Specification D Equipments Details a Dental Chair b Micromotor c Contra Angle Hand Piece d Straight Hand Piece Scalar d e 34 Public address system 35 Demonstration model assorted model to impart training and education 36 Scaler 1 Description of Function 1 1 Dental Scaler is required for removing the supragingival and subgingival calculus 2 Operational Requirements 2 1 Microprocessor based system 3 Technical Specificat
59. on control with optional foot controlled It should have two working modes i e continuous or pulse Fibre core should be of 200 amp 400 microns Laser emission Alert should be Audible and Visible Sign Aiming beam should be 635mm Imw controllable Laser delivery should be with through stripped fibers It should be supplied with 03 safety goggles Surgical motor With physio dispenser Page 42 of 55 Extremely light amp compact with low vibration amp powerful brushless micro motor e Non sterilizable motor speed range without contra angle 400 to 30 000 RPM Non sterilizable motor speed range with a 20 1 contra angle 20 to 1 500 RPM Non sterilizable motor torque with a 20 1 contra angle up to 54N cm e 5no s program can be stored amp auto stop facility is available amp 4no s different flow rate is available max 100ml min e Easy to use large amp visible front panel e Multifunction progressive type foot switch For sterile work the micro motor amp the cord should be inserted in the sterile protection e Supply voltage 220V 50Hz 60Hz Equipment classification Class II B type 154 Ultrasonic Fixation for Resorbable with Complete Set e The instruments quoted should be of high quality and ASTM F899 or of equivalent standard specifications for the material used e Should be European CE USFDA certified and must enclose the certificate e All the instruments should be quoted alo
60. onthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out RVG It should be based on advanced Hybrid latest CMOS Technology It should have tapered sensor edges to maximize the patient comfort amp for human oral structure It should have Ergonomic design targets form amp function to ensure the optimal environment of comfort amp functionality It should have minimum 1 million exposure life It should have Pixel Pitch not more than 0 035mm It should have Dynamic Range Grey scale not more than 4096 It should have Active Pixel Array Minimum 24 01x33 04mm It should have dimension W L Minimum 29 2x38 7 mm Page 29 of 55 8 It should have Superior image quality with reduced scan time with low x ray dose or radiation Sensor Case Aluminium case makes perfect ground amp protect CMOS sensor from mechanical amp electrical shocks It should have flexible cable which is bend resistent It should have minimum cable length of 3 meter Sensor thickness should not be more than 5mm It should have Plug in type USB 2 0 PC Interface guarantees the user convenience and simple interaction It should have integrated software program for diagnosis communication and patient database tool password protected with following features user friendly software Easy to learn amp convenient to use All kind of image formats supported
61. or maintaining proper sterilization while working Color temperature of the light should be around 5000 Angstroms Light should allow Vertical Horizontal and Axial amp Diagonal Movements for proper Focusing Page 24 of 55 gt Oil Free Air Compressor Medical Grade It should have Air moisture filter It should have Non retraction valve It should have Pressure gage It should have Air tank capacity of 30 40 Lt It should have Auto cut off switch It should give medical grade Air which is absolutely oil free gt Technical Features 1200 1500 R P M 230 Voltages 50 Hz gt LED Light Cure Unit Modular Light Cure Unit Specifications Advances in the power output of light emitting diodes LEDS have allowed a LED light curing unit LCU with an 8 mm diameter light guide tip to achieve a similar depth of cure ina camphorquinone photo initiated composite as a halogen LCU Blue LEDs can be used as photo detectors and may be of future use in dental radiometers When assessing the output from an LCU it is not only important to know the spectrum and irradiance but also whether the emission is pulsed or continuous gt Foot Control Single foot control for all instruments with variable speed control gt Dental Stool Stable with 5 castor base with load stabilizing gas spring Backrest tilt should be adjustable 2 Nos One for Dental surgeon and one for Assistant gt Modular Furnitures with sink and tap as per the site require
62. ow speed Increase or decrease speed increase decrease water flow rate 2200p c Cutting Accessories a Should have blades for oscillating Sagittal amp reciprocating saw All the systems should be US FDA approved 46 47 48 49 50 51 52 53 54 Rows Maxillary disimpaction foreceps left and right Hyton William forceps forward amp downward traction Harrison mandible holding with speed lock Asch Nasal septum foreceps Walsham nasal septum Bone and plate holding Reduction bone holding Chin segment Maxillary bone graft holding Page 39 of 55 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 Mandible bone graft holding TMJ spreading foreceps Czerney retractor Double hook skin retractor Mcindoe retractor Rayne mandibulr retractor Davis double ended retractor Chin retractor Forked ramus retractor Channel retractor Kilner retractor Haejeck cheek retractor Kilner nasal retractor Kilner skin retractor double ended Farabeuf retractor Malleable copper retractor Austin tissue retractor Smith spreader retractor Right angle Lengenback retractor small medium and large Condylar neck retractor Brown lingual flap retractor left and right Volkman retractor Rowe orbital floor retractor Mcdonald dissector Periosteal elevators Dental elevators x
63. ptimal magnification while providing extended field of view It should have a flip up facility It should have a Magnification of 2 5X It should have Working distance 420mm R It should have 90mm Depth of view R It should have 100mm Field of View R It should have Weight not more than 42g It should have Frames made up of Ni alloy Elevators Should be crafted from Immunity Steel and heat treated to provide optimal sharpness and durability Full Set of Dental Elevators for extractions of all the teeth including the impacted tooth US FDA Eurupian CE approved Surgical micromotor Speed upto 35 000to 40 000 RPM Long working without any heat One spare carbon brush set Low heat generation suitable for long use Smooth bearing for low noise and durability It should have Forward amp Reverse direction selection It should have Hand amp Foot Operation Surgical micro motor unit with facility of saline irrigation It should have Extra torque for smooth working One autoclavable Surgical micro motor straight hand piece one FDA CE approved Instruments for Bone plating amp other major surgery Oscilating saw with all attachments Specification for micro saw Micro Reciprocating Saw a Should cut in a Perpendicular Line b Should have Maximum speed of 14000 cpm c Maintenance free D C brush less motor d Snap lock assembly and disassembly of all attachments e Sterilizable through steam ETO and Flash Micro Osc
64. r any other documents related to sales tax entry tax on their own If any of the above enclosures are of more than one page then in the page number columns write clearly on page no to page no Without filling the compliance report the offer will be rejected directly at the time of technical evaluation Page 9 of 55 4 All the bidders have to provide soft copy of their technical specifications same as they have submitted in hard copy of technical bid in PEN drive also PEN drive must be submitted by all the bidders at the time of opening of technical bid in front of purchase committee Certificate of Compliance e ls ae ds Cot eee eee on behalf of M s Name of firm company eE aa E EE EE DAA tahini Miers ns sol Ustad aca teialaics do hereby confirm that have verified the above compliance report it is duly filled Our technical bid consists of total No of pages EET NWOT Se ariga r a a a aea Signature of the Bidder with date amp seal of the firm company 22 Please enclose photocopies of your complete registration certificate with DGS amp D NSIC DGQA if any as applicable which should be valid on the date of tender opening 23 Price bid of technically acceptable offers would only be opened for which either the respective firm would be invited through telephone fax or the same may be opened with display in the notice board in case telephone message can not be passed on 24 The fol
65. rd 1 2 Hirschfeld 3 7 Hirschfeld 5 11 a b c d Hirschfeld 9 10 SS a TS a ix Orban 10 11 a Orban 12 13 b Sugarman 1 2 c Sugarman 3 4 d Schluger 9 10 x Furcation Curettes 1 2 3 4 5 xi Periodontal Knives a Goldman Fox 11 b Kirkland 15 16 c Orban 1 2 xii Scalpel Blade Handles xiii Periosteal Elevators a Molt 9 b Woodson 1 Modified xiv Micro Surgery Tunnel Surgery Instruments a Papilla Retractor 1 b Papilla Retractor 2 c Papilla Retractor 3 d Papilla Retractor 4 xv Castroviejo Scissors xvi Castroviejo Needle Holder xvii Retractors xviii Tissue Forceps a Adson b Adson Brown xix Corn Suture Pliers Page 45 of 55 xx Scissors a Iris b Straight blades c Curved blades d Suture e Sullivan xxi Needle Holders xxii Sinus Lift Curettes Fig 1 2 3 4 5 xxiii Bone Condenser xxiv Bone Files xxv Periotome handle and working tip all sizes 166 Articulator semiadjustable 167 Extra oral intra oral tracer 168 Hot water sterilizer Hot amp Cold water sterilizer electrically operated double tanks each with 45 ltrs hr capacity The chamber should be of stainless steel The unit should be with low water protection and Automatic Pressur cut off device Special arrangement for cooling of sterile water to required temperature With Boiler having safety valve water filter Steam release valve pressure gauge Dial
66. rt number and costing 7 3 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out 4 Ultrasonic cleaner It should have lengthened tank suitable for long dental instruments e It should have stronger transducer to get better cleaning effect It should have digital timer for choosing different time of cleaning e It should have circuit protector amp radiator fan to protect every parts in good condition after long working time It should have Ultrasonic frequency 42 000 Hz It should have stainless steel tank e It should have tank capacity of 10 Liter It should have tap system to evacuate water from the tank e Elegant fibreglass casing for hygienic and rust free equipment with mesh bucket e should be efficient enough to remove the dirt and debris from the crevices of instruments 5 Needle burner with syringe cutter It is table top elegant look and capable of providing 1300 C within a fraction of a second to melt the entire metalic portion of the needle It has a high speed Motor with high speed HSS long lasting cutter Motor is having auto start as soon as you introduce the syringe and slide It can cut the syringe within a fraction of a second Waste Container Tray is large enough to hold at least 150 200 cut plastic syringes 6 Intra oral x ray e Description of Function
67. sitioning beams for accurate positioning It should have Hybrid CMOS sensor technology It should have 2 separate sensors for panoramic amp cephlometric It should have collimator Automaticlly moved by moter It should have voltage 50 90kv It should have current 4 10 mAmp It should have Focal spot 0 5 x 0 5 mm It should have Grey Scale 14 Bit It should have Pixel pitch 100 It should have Rotating unit scan angle 220 Degree It should have Patient positioning Standing wheel chair accessible It should have different capture mode Panoramic Programs 16 Standard Panoramic program Normal Narrow Wide High Resolution program Child Program Segments left right front TMJ Programs Lateral PA Sinus Programs Lateral Sinus Special Programs Orthogonal Bitewing left right incisor Ceplomatric Lateral PA AP SMV Water View and Carpus It should haveScan time Normal less than 11 sec high resolution 14 sec Pana 13 sec Ceph It should have Image Magnification 1 30 1 panaramic 1 14 1 cephalometric It should have High Frequency generator High Voltage DC Constant potential microprocessor controlled It should be supplied with Compatible computer system Inkjet printer and UPS It should have ISO CE certification It should be AERB approved 70mA 110KV high frequency x ray machine 40KHz with spring balanced mobile stand 1 Description of Function 1 1 This equipment enables digit
68. stributions Quantity i Operation instructions With each equipment 2 sets each ii Wiring diagram Inspecting authority 2 sets Concerned authority iii Maintenance service manual Inspecting authority 2 sets iv Spare parts lists indicating cost Concerned authority 2 sets d The tenderers should quote the latest models Quotations for out dated models of equipments will not be entertained 41 Price bids and technical bids should be separately sealed covers duly superscribed Both the bids should be in duplicate Both these sealed bids should be put in another main envelope duly sealed amp mentioning following informations Tender notice no 3422 dated 02 06 2015 for the department of Dental Institute RIMS Date amp time of opening 21 07 2015 at 12 30 P M Director Rajendra Institute of Medical Sciences Ranchi Signature of Tenderer Name in block letters Capacity in which tenderer is signed Address in full Dated Seal Page 12 of 55 OFFICE OF THE DIRECTOR RAJENDRA INSTITUTE OF MEDICAL SCIENCES RANCHI amp 834009 JHARKHAND Tender Notice No 3422 RIMS Ranchi Dated 02 06 2015 NOTICE INVITING TENDER Due to unavoidable circumstances the previous tender notice no 1008 dated 22 02 2014 is being cancelled and new sealed offers are invited in two bid system Technical amp Price bid by Speed post Registered post only from original equipment manufacturer or authorized dealer for Supply
69. t epoxy paint finish 3 Should have seamless ultra thin upholstery to facilitate easy cleaning disinfecting 4 Double articulating headrest for comfortable support Should have flip head rest to be used on patients on wheelchairs 5 Footswitch with multifunction It should provide all chair movements adjustable and Programmable position movement of return to zero and emergency stop 6 The hand rests should be fully adjustable and should rotate out of the way of the patient when he steps off 3 2 Dental Unit Specifications 1 Should be attached to the chair with overhead underhead delivery system to accommodate up to following 4 modules a One Turbine connections with hand piece b One air motor connection with air motor and hand pieces straight amp contra c One fiber optic air rotor connection with quick disconnect coupling and light cure unit to be attached to the same coupling d One 3 way syringe with removable tip for sterilization e All the controls of the chair should be touch pad on doctor s and assistant s sides 2 The design should be such that it can be simply cleaned and disinfected to reduce the possibility of cross infection Autoclavable pad should be provided on the Unit where the hand pieces are placed 3 Should have to reservoirs of water and disinfectant with automatic pressurization 4 Should have a non retraction valve to avoid the reflux of contaminated materials 3 3 Spittoon Water Unit Specific
70. thermometer etc 169 Geyser 170 Distill water apparatus LAB EQUIPMENTS 171 Plaster dispenser should have Electric controlled unit should have On Off control Switch should have provision for Wall Mounted should have plaster quality at steady rate should have Capacity of 10 kgs 172 Madel trimmer with carborandum disc should have 1400 rpm motor should have solenoid valve adjusting the quantity of water should have bakelite disc is reversible should work on 230V AC mains 173 Madel trimmer with diamond disc should have 1400 rom motor should have solenoid valve adjusting the quantity of water should have Diamond coated disc should work on 230V AC mains 174 Pressure moldings machine Page 46 of 55 It should be equipped with heat insulating material and devices It should have a timer to prevent overheating of heater It should have fuse to prevent overload It should have noise filter Power Supply 110 or 220 V 50 60 Hz Heater Output 550 W Motor Output 1250 W It should have a CE certification It should be supplied with 100 sheets for fabrication of appliance It should be able to fabricate Splint ortho retainer Surgical implant stent Temporary crown amp bridge form Bleaching fluoride tray and Night mouth guard 175 Vibrators should have capacity of 3 4 casting cylinder should have removable Rubber Plate for Easy Cleaning should have controller for variable vibrational frequencies 176 Wel
71. tion Contractor Seller hereby declare that the goods stores articles sold supplied installed to the purchaser under this contract shall be of the best quality and workmanship and new in all respects and shall be strictly in accordance with the specification amp particulars mentioned in the contract The contractor seller hereby guarantees that the said goods articles would continue to confirm to the description and quality aforesaid for a period of Five years from the date of final installation a Warranty to the effect that before joining out of production for the spare parts they will give in adequate advance notice to the purchaser of the equipment so that the later may undertake the balance of the life time requirements b Warranty to the effect that they will make available the blue prints of drawings of the spares if amp when required in connection with the main equipment Page 11 of 55 40 The following clauses are required to be confirmed a Free routine servicing at least 2 visits of their engineers at site in one year will be carried out by the firm till guarantee period b The firms will make available full engineer support package ESP including essential maintenance and recommended spares for maintenance of the equipment for further 05 years after the guarantee period c _ The following set of documents in respect of the equipments are also required to be supplied by the firm Literature Di
72. uency 28 36 KHz with 4 scaler tips and one set of perio curette tips The over head delivery system should have balanced flax arms with pneumatic bracket The handpiece control block should flow through water design to eliminate stagnant water Built in antiretraction valves and flush valve system for infection control Autoclavable quick disconnect water syringe Micromotor with speed range of 300 40000 RPM in standard mode with cutting power in the range between 50 70 watts The micromotor should have an endodontic mode 0 The assistant side shoud have high suction low vacum suction light cure system and 3 way syringe 11 X Ray viewer LED Based 12 It should be supplied with following handpieces all CE certified Genuine instruments a Fibre optic Air rotor nos 1 scratch resistant Titanium Body b Fibre optic Micromotor straight nos 1 scratch resistant Titanium Body c Fibre optic Micromotor contra angle miniature nos 1 scratch resistant Titanium Body d Scaler Handpiece with Standard tips ONDARE WMP O 1 D Cuspidor Saliva ejector Autoclavable High volume evacuator Autoclavable syringe High quality stain proof vitreous China bowl removable with adjustable cup fill and bowl rinse timers 5 Clean water bottle system EOM 1 E Operating Light 1 With luminosity of 20000 lux and 25000 lux with maximum degrees of rotation of light arm movements 2 Light Head with axial movements Horizontal Vertical Axial an
73. ut charging any extra cost under warranty amp C M C 3 For Dental Chair and its compatible accessories i the price will be compared on the whole basis i e the price comparative will be prepared by including all the compatible accessories amp accordingly compared Preference will be given to the bidders who have experience of installing minimum of 25 dental chairs at a time in more than 5 Government institutions ii The bidders have to provide a central compressed air system arrangements for running functioning of the installed dental chairs A central compressed air system room will be provided by the institute in the institute building all the equipments amp accessories to run the compressed air system with attachment to dental chair have to be provided by the bidders on turnkey basis iii The bidders have to confirm the names manufacturing quality quantity with their make for hand pieces straight contra angled which they will provide supply free of cost with the dental chair Also they have to provide seperate rates of the hand pieces Full signature of the tenderer with seal Sd Director Ea A E Rajendra Institute of Medical Sciences Name Ranchi in capital letters Designation List amp specifications of equipments Separate list is enclosed herewith this tender documents All the bidders have to get it confirmed at the time of purchase of tender documents The bidders have to mention clearly the names and technica