Home

Tektronix TBS1000B Series Datasheet

image

Contents

1. Horizontal zoom Horizontally expand or compress a live or stopped waveform 1 Bandwidth is 20 MHz at 2 mV div www tektronix com 5 Datasheet Input Output ports USB interface GPIB interface Data storage Nonvolatile storage Reference waveform display Waveform storage without USB flash drive Maximum USB flash drive size Waveform storage with USB flash drive Setups without USB flash drive Setups with USB flash drive Screen images with USB flash drive Save All with USB flash drive Acquisition system Acquisition modes Peak Detect Sample Average Single Sequence Roll Trigger system External trigger input Trigger modes Trigger types Edge Rising Falling Video Pulse Width or Glitch Trigger source Trigger view Trigger signal frequency readout 6 www tektronix com USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all PictBridge compatible printers Optional 2 5K point reference waveforms 2 5K point 64 GB 96 or more reference waveforms per 8 MB 10 front panel setups 4000 or more front panel setups per 8 MB 128 or more screen images per 8 MB the number of images depends on file format selected 12 or more Save All operations per 8 MB A single Save All operation creates 3 to 9 files setup image plus one file for each displayed waveform High frequency and random glitch capture Capture
2. PWM pulse train if set to lt mode and the limit is set to a relatively small number Edge Trigger mode Counts all pulses of enough magnitude 2 channel www tektronix com 7 Datasheet Display system Interpolation Waveform styles Persistence Format Physical characteristics Dimensions Shipping dimensions Weight RM2000B rackmount Environmental Temperature Operating Nonoperating Humidity Operating and nonoperating Altitude Operating and nonoperating Regulatory Electromagnetic compatibility Safety 8 www tektronix com Sin x x Dots vectors Off 1s 2 s 5s infinite YT and XY mm in Height 158 0 6 22 Width 326 3 12 85 Depth 124 2 4 89 mm in Height 266 7 10 5 Width 476 2 18 75 Depth 228 6 9 0 kg Ib Instrument only 2 0 4 3 with accessories 2 2 4 9 mm in Width 482 6 19 0 Height 177 8 7 0 Depth 108 0 4 25 0 to 50 C 40 to 71 C Up to 85 RH at or below 40 C Up to 45 RH up to 50 C Up to 3 000 m 9 843 ft Meets Directive 2004 108 EC EN 61326 2 1 Class A Australian EMC Framework UL61010 1 2004 CSA22 2 No 61010 1 2004 EN61010 1 2001 IEC61010 1 2001 Ordering information Models TBS1052B TBS1072B TBS1102B TBS1152B TBS1202B Language options Opt L1 Opt L2 Opt L3 Opt L4 Opt L5 Opt L6 Opt L7 Opt L8 Opt L9 Opt L10 Power plug
3. Phase Pos Pulse Cnt Neg Pulse Cnt Rise Edge Cn Fall Edge Cn Pos Duty Neg Duty Amplitude Cycle Mean Cursor Mean Burst Width Pos Overshoot Neg Overshoot Area Cycle Area High Low Delay RR Delay RF Delay FR Delay FF Add Subtract Multiply FFT Windows Hanning Flat Top Rectangular 2048 sample points Two channel models CH1 CH2 CH2 CH1 CH1 CH2 CH1 x CH2 Single button automatic setup of all channels for vertical horizontal and trigger systems with undo Autoset Single Cycle Multicycle Rising or Falling Edge Single Cycle Multicycle FFT Spectrum Field All Odd or Even Line All or Selectable Line Number Automatically adjust vertical and or horizontal oscilloscope settings when probe is moved from point to point or when the signal exhibits large changes 6 digits 51 parts per million including all frequency reference errors and 1 count errors AC coupled 10 Hz minimum to rated bandwidth Pulse width or edge selected trigger source Frequency counter measures selected trigger source at all times in pulse width and edge mode including when the oscilloscope acquisition is halted due to changes in run status or acquisition of a single shot event has completed The frequency counter does not measure pulses that do not qualify as legitimate trigger events Pulse Width mode Counts pulses of enough magnitude inside the 250 ms measurement window that qualify as triggerable events e g all narrow pulses in a
4. front panel enables you to save your instrument settings screenshots and waveform data onto a USB memory device This port also supports the built in Data Logging feature which enables you to set up the oscilloscope to save user specified triggered waveforms to a USB device for up to 24 hours You can also select the Infinite option for continuous waveform monitoring In the infinite mode you can save your triggered waveforms to an external USB memory device without a duration limitation until the memory device is full The oscilloscope will then guide you to insert another USB memory device to continue saving waveforms a u Siop M Pos 0 000s DataLoggir DataLogging On Off Ji Source Ch1 E Duration 30 min Select Folder Back Nov 19 2013 14 53 Please wait Data logging enables automatic saving of triggered waveforms Designed to make your work easy The TBS1000B series oscilloscopes are designed with the ease of use and familiar operation you have come to expect from Tektronix Intuitive operation The intuitive user interface with dedicated per channel vertical controls auto setup and auto ranging makes these instruments easy to use reducing learning time and increasing efficiency www tektronix com 3 Datasheet Help when you need it where you need it Performance you can count on The built in Help menu provides you with important information about yo
5. passive probe for TBS1152B TBS1202B Power cord Please specify plug option NIM NIST Traceable certificate of calibration Printed documentation Installation and safety manual English Japanese and Simplified Chinese CD with customer documentation Customer documentation including detailed user manuals English French German Italian Japanese Korean Portuguese Russian Simplified Chinese Spanish Traditional Chinese 5 year warranty Covers labor and parts for defects in materials and workmanship for 5 years excluding probes and accessories probes and accessories are not covered by the oscilloscope warranty and service offerings refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms Recommended accessories Accessory Description TEK USB 488 GPIB to USB converter AC2100 Soft carrying case for instrument HCTEK4321 Hard plastic carrying case for instrument requires AC2100 RM20008 Rackmount Kit 077 0444 xx Programmer manual English only 077 0772 xx Service manual English only 174 4401 xx USB host to device cable 3 ft long Recommended probes Probe Description TPP0051 10X passive probe 50 MHz bandwidth TPP0101 10X passive probe 100 MHz bandwidth TPP0201 10X passive probe 200 MHz bandwidth P2220 1X 10X passive probe 200 MHz bandwidth P6101
6. 010 Luxembourg 41 52 675 3777 Mexico Central South America amp Caribbean 52 55 56 04 50 90 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 00800 2255 4835 Norway 800 16098 People s Republic of China 400 820 5835 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia amp CIS 7 495 6647564 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2255 4835 Switzerland 00800 2255 4835 Taiwan 886 2 2722 9622 United Kingdom amp Ireland 00800 2255 4835 USA 1 800 833 9200 European toll free number If not accessible call 41 52 675 3777 Updated 10 April 2013 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and EX price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies Sy 10 Mar 2014 3GW 30004 1 www tektronix com Tektronix S
7. B 1X passive probe 15 MHz 300 V RMS CAT II rating P6015A 1000X high voltage passive probe 75 MHz P5100A 100X high voltage passive probe 500 MHz P52000A 0 MHz 50X 500X high voltage differential probe tts P6021A 15 A 60 MHz AC current probe P6022 6 A 120 MHz AC current probe A621 2000 A 5 to 50 kHz AC current probe A622 100 A 100 kHz AC DC current probe BNC TCP303 TCPA300 150 A 15 MHz AC DC current probe amplifier TCP305A TCPA300 50 A 50 MHz AC DC current probe amplifier 10 www tektronix com TBS1000B Digital Storage Oscilloscopes Probe Description TCP312A TCPA300 30 A 100 MHz AC DC current probe amplifier TCP404XL TCPA400 500 A 2 MHz AC DC current probe amplifier Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar PIB Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats IEEE 488 www tektronix com 11 Datasheet ASEAN Australasia 65 6356 3900 Austria 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 00800 2255 4835 Brazil 55 11 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 00800 2255 4835 Germany 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835 Japan 81 3 6714 3
8. Tektronix Digital Storage Oscilloscopes TBS1000B Series Datasheet The TBS1000B Digital Storage Oscilloscope Series provides you with affordable performance in a compact design Packed with standard features including USB connectivity 34 automated measurements limit testing data logging frequency counter TrendPlot and a context sensitive help menu the TBS1000B Series oscilloscopes helps you get more done in less time Key performance specifications 200MHz 150 MHz 100 MHz 70 MHz and 50 MHz bandwidth models 2 channel models Up to 2 GS s sample rate on all channels 2 5k point record length on all channels Advanced triggers including pulse and line selectable video triggers Key features 7 inch WVGA 800X480 Active TFT Color Display 34 automated measurements Dual window FFT simultaneously monitors both the time and frequency domains Built in waveform limit and TrendPlot testing Dual channel frequency counter Zoom Function Automated extended data logging feature Autoset and auto ranging functions Built in context sensitive help Multiple language user interface Small footprint and lightweight Only 4 9 in 124 mm deep and 4 4 lb 2 kg Connectivity USB 2 0 host port on the front panel for quick and easy data storage USB 2 0 device port on rear panel for easy connection to a PC Seeing signal details To properly analyze signals you need t
9. _max1 1 23 DelayFR Source2 CH1 2 TP2 Scale_min1 1 23 PK PK TP2 Min 1 2345KHz Max 1 2345KHz Avg 1 2345KHz 2 ERY 4 00us 0 000000s TP2 Scale 1kHz Total 00 10 26 Oct 29 10 21 22 To find intermittent faults the TrendPlot function can monitor measurements for long periods of time Often only Pass Fail data is needed to determine if a signal is good This can be accomplished easily with the TBS1000B Limit Test feature The oscilloscope can be set up to automatically monitor a source signals and output Pass or Fail results by evaluating whether the acquired waveform falls within predefined boundaries The TBS1000B Limit Test feature allows users to create templates based on one or two independent reference waveforms providing more flexibility when creating masks for complex signals If a failure is detected a series of specific actions can be triggered which include stopping waveform acquisition halting Limit Test functions saving a screen image of the failed waveform or any combination of the above Source Ch1 Compare To Ref A Run Stop Test Run Stop Template Setup more page 1 of 2 TENS Ca Nov 19 2013 14 44 o usb0 1914 The Limit Test feature provides a quick Pass Fail comparison between any triggered input signal and a user defined template TBS1000B Digital Storage Oscilloscopes Flexible data transfer The USB host port on the
10. ckly and reliably calculate important signal characteristics such as frequency rise time or overshoot 2 www tektronix com Please wait Nov 19 2013 11 14 Quickly perform an FFT with a dedicated front panel button For accurate frequency measurements the TBS1000B also comes with built in dual channel frequency counters Independent control of each counter s trigger level provides an easy way to monitor two different signal frequencies simultaneously Tek E Tria d Ch1 On Off Ch2 On Off Ch1 Trigger 880 0mV C RTE Ch2 Trigger D 03945MHz 2 000 SST D 2 00V M 1 00ms Please wait Nov 19 2013 11 17 Dual channel 6 digit frequency counters come standard with all TBS1000 models Extensive monitoring and analysis tools Intermittent faults can be hard to evaluate simply because they do not repeat often making them difficult to capture The TrendPlot function helps find those faults by plotting measurement values over long periods of time Select the measurement to capture on either or both channels and then set up the oscilloscope to continuously monitor those measurements plot the data on the display and simultaneously save the information to a USB thumb drive Depending on the oscilloscope setting you ll be able to capture data for minutes hours or even days the only limitation is the size of the thumb drive Tek TrendPlot Run Stop Source1 CH1 D Typet Scale
11. o make sure that you can see them in enough detail The TBS1000B comes standard with a 7 inch high resolution TFT display for a clear view of all of your signals and critical on screen information The instrument is further enhanced by a user interface inspired by the award winning Tektronix MSO DPO series of instruments The interface is easy to use provides quick access to all of the oscilloscope functions and includes a high resolution Pan amp Zoom feature enabling you to see even more signal details of up to 10 times normal resolution M Pos 0 000s JOM1 00ms sh 42 62V__ 1 00745kHz Nov 20 2013 13 19 The zoom function shows details in an event of up to 10X the normal view www tektronix com 1 Datasheet Digital precision for accurate measurements With up to 200 MHz bandwidth 2 GS s maximum sample rate and 3 vertical measurement accuracy the TBS1000B allows you to see the details of your signals With the Tektronix proprietary sampling technology there are no compromises you will get the stated real time sampling rate on all channels all the time with at least of 10X oversampling The sampling performance is not reduced when changing horizontal settings or when using multiple channels enabling you to see the true characteristics of your signals H Trig d M Pos a Co M 50 0ns J cm1 7 320mv__ 10 0kHz_ Measure Period Gating Frequency On Off Pk Pk Minimum Ch1 Maxim
12. options Opt A0 Opt A1 Opt A2 Opt A3 Opt A5 Opt A6 Opt A10 Opt A11 Opt A12 Opt A99 Service options Opt D1 50 MHz 2 Ch 1 GS s TFT DSO 70 MHz 2 Ch 1 GS s TFT DSO 100 MHz 2 Ch 2 GS s TFT DSO 150 MHz 2 Ch 2 GS s TFT DSO 200 MHz 2 Ch 2 GS s TFT DSO French overlay Italian overlay German overlay Spanish overlay Japanese overlay Portuguese overlay Simplified Chinese overlay Traditional Chinese overlay Korean overlay Russian overlay North America power plug 115 V 60 Hz Universal Euro power plug 220 V 50 Hz United Kingdom power plug 240 V 50 Hz Australia power plug 240 V 50 Hz Switzerland power plug 220 V 50 Hz Japan power plug 100 V 110 120 V 60 Hz China power plug 50 Hz India power plug 50 Hz Brazil power plug 60 Hz No power cord Calibration Data Report TBS1000B Digital Storage Oscilloscopes Probes and accessories are not covered by the oscilloscope warranty and Service Offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms www tektronix com 9 Datasheet Probe option TBS1XX2B P2220 Standard accessories Replaces standard probes with P2220 probes 200 MHz passive voltage probes with 1x 10x attenuation Accessory Description Passive probes one per channel TPP0051 50MHz passive probe for TBS1052B TPP0101 100 MHz passive probe for TBS1072B TBS1102B TPP0201 200 MHz
13. s glitches as narrow as 12 ns typical at all time base settings from 5 us div to 50 s div Sample data only Waveform averaged selectable 4 16 64 128 Use the Single Sequence button to capture a single triggered acquisition sequence At acquisition time base settings of gt 100 ms div Included on all models Auto Normal Single Sequence Conventional level driven trigger Positive or negative slope on any channel Coupling selections AC DC Noise Reject HF Reject LF Reject Trigger on all lines or individual lines odd even or all fields from composite video or broadcast standards NTSC PAL SECAM Trigger on a pulse width less than greater than equal to or not equal to a selectable time limit ranging from 33 ns to 10 s Two channel models CH1 CH2 Ext Ext 5 AC Line Displays trigger signal while Trigger View button is depressed Provides a frequency readout of the trigger source Waveform measurements Cursors Types Measurements Automatic measurements Waveform math Arithmetic Math functions FFT Sources Autoset Autoset menu Square wave Sine wave Video NTSC PAL SECAM Autorange Frequency counter Resolution Accuracy typical Frequency range Frequency counter signal source Channels TBS1000B Digital Storage Oscilloscopes Amplitude Time AT 1 AT AV Period Frequency Pos Width Neg Width Rise Time Fall Time Maximum Minimum Peak Peak Mean RMS Cycle RMS Cursor RMS
14. um l Rising Time Falling Time ena Pos Pulse Cnt Neg Pulse Cnt Math Falling Edge Cnt Rising Edge Cnt Mean SnapShot C JC CTE It Use multipurpose knob to select measurement t Nov 19 2013 16 20 Quickly analyze signals with the standard 34 automated measurements A dedicated front panel button provides quick access to the FFT function that is capable of showing both frequency and time domain waveforms simultaneously which provides a convenient way to see the relationship between signals and the FFT results E Tria d Pos 62 50kHz Nov 19 2013 15 57 See all the details other oscilloscopes might miss with Tektronix proprietary digital real time sampling Critical tools for troubleshooting your device The TBS1000B oscilloscope comes standard with a variety of advanced triggers used to debug today s complex circuitry Flexible options for utilizing rising or falling edges pulse widths and video trigger set ups enable users to quickly isolate their signals of interest Tek u Tria d Type Pulse Source Ch1 Pulse Width 4 73ms more page 1 of 2 aoo CPST cmn 272v__1 00733kHz Nov 20 2013 16 46 The pulse trigger function can easily capture critical events Once signals are captured the TBS1000B offers advanced math and measurement capabilities making it easy to evaluate signal quality Users can add subtract and multiply waveforms or use any one of 34 automated measurements to qui
15. ur In addition to industry leading service and support every TBS1000B series oscilloscope s features and functions Help is provided in the same oscilloscope comes backed with a 5 year warranty as standard languages as the user interface Automatic Measurements The context sensitive help system provides important information specific to the task you are working on 4 www tektronix com Specifications All specifications apply to all models unless noted otherwise Model overview TBS1000B Digital Storage Oscilloscopes TBS1052B TBS1072B TBS1102B TBS1152B TBS1202B Bandwidth 50 MHz 70 MHz 100 MHz 150 MHz 200 MHz Channels 2 2 2 2 2 Sample rate on each channel 1 0 GS s 1 0 GS s 2 0 GS s 2 0 GS s 2 0 GS s Record length 2 5k points at all time bases Vertical system Analog channels Vertical resolution 8 bits Input sensitivity range 2 mV to 5 V div on all models with calibrated fine adjustment DC gain accuracy 3 from 10 mV div to 5 V div Maximum input voltage 300 Vams CAT Il derated at 20 dB decade above 100 kHz to 13 Vp p AC at 3 MHz and above Offset range 2 mV to 200 mV div 1 8 V gt 200 mV to 5 V div 45 V Bandwidth limit 20 MHz Input coupling AC DC GND Input impedance 1 MQ in parallel with 20 pF Vertical zoom Vertically expand or compress a live or stopped waveform Horizontal system Analog channels Time base range 2 5 ns to 50 s div Time base accuracy 50 ppm

Download Pdf Manuals

image

Related Search

Related Contents

  A-1 - Newport Corporation  水平多関節ロボットIXシリーズ 卓上型アーム長500/600/700/800用 IX  取扱説明書ダウンロード  M-crew for HAR-LH500 (Version 2.6J)  

Copyright © All rights reserved.
Failed to retrieve file