1. Frequency Frequency range 9 kHz to 3 GHz 9 kHz to 7 GHz 9 kHz to 13 6 GHz 9 kHz to 30 GHz 9 kHz to 40 GHz Frequency resolution 0 01 Hz Internal reference frequency nominal Aging per year 1x 10 Temperature drift 1x 1079 With option R amp S FSP B4 0CXO Aging per year 1x 107 Temperature drift 1x 10 External reference frequency 10 MHz Frequency display with marker or frequency counter arker resolution Span 500 ax deviation sweep time gt 3 x auto sweep time frequency x reference frequency 0 5 x span 10 x resolution bandwidth 2 last digit Frequency counter resolution 0 1 Hz to 10 kHz selectable Count accuracy S N gt 25 dB x frequency x reference frequency 42 last digit Frequency span 0 Hz 10 Hz to 3 GHz O Hz 10 Hz to 7 GHz 0 Hz 10 Hz to 13 6 GHz 0 Hz 10 Hz to 30 GHz 0 Hz 10 Hz to 40 GHz ax span deviation Spectral purity dBc 1 Hz SSB phase Carrier offset 0 1 rasa 50 Mo gt SD ee dans n ST 100 Hz lt 84 typ 90 1 kHz 100 typ 108 10 kHz lt 106 typ 113 100 kHz lt 110 typ 113 1 MHZ lt 120 typ 125 10 MHz typ 145 Residual FM f 500 MHz RBW 1 kHz typ 3 Hz sweep time 100 ms 1 After 30 days of operation Valid for span gt 100 kHz 2 R amp S FSP Spectrum Analyzer Typ
2. Temperatures e Operating temperature range 5 C to 40 C Permissible temperature range 5 C to 45 C Storage temperature range 40 C to 70 C Damp heat 40 C at 95 relative humidity EN 60068 2 30 Mechanical resistance d gt Vibration sinusoidal 5 Hz to 150 Hz max 2 g at 55 Hz 0 5 g from 55 Hz to 150 Hz meets EN60068 2 6 EN 60068 2 30 EN61010 1 MIL T 28800D class 5 Vibration random 10 Hz to 100 Hz acceleration 1 g rms Shock test 40 g shock spectrum meets MIL STD 810C and MIL T 28800D classes 3 and 5 Recommended calibration interval 2 years for operation with external reference 1 year with internal reference Power supply AC supply 100 V AC to 240 V AC 50 Hz to 400 Hz 3 1 A to 1 3 A class of protection to VDE411 Typical power consumption 70 VA 120 VA 150 VA Safety meets EN61010 1 UL3111 1 CSAC22 2 No 1010 1 RFI suppression meets EMC Directive of EU 89 336 EEC and German EMC law Test mark VDE GS CSA CSA NRTL C Dimensions in mm W x H x D 412 x 197 x 417 Weight 10 5 kg 11 3 kg 12 kg 1 2 RF attenuation 10 dB sweep time gt 1s 1 GHz See recommended extras for alternate connectors R amp S FSP Spectrum Analyzer 7 Specifications of options Tracking Generator R amp S FSP B9 Unless specified otherwise specifications not valid for frequency range from 3 x RBW to 3 x RBW howev
3. Thus importance was placed on maxi mum compatibility in order to minimize the necessity for changes Approx 175 commands in IEEE 488 2 format incl CF AT ST The most important commands in IEEE 488 1 format 85664 for exclusive use only Selectable presets Selectable trace format 8560E to 8565E 8566A B 8568A B and 8594E are supported The IEC IEEE bus commands in IEEE488 2 format can be used together with the R amp S FSP com mand set making it possible to enhance and complete available software by using the innovative instrument functions of the R amp S FSP such as list mode channel fil ters without having to redesign the test software for production Spectrum Analyzer R amp S FSP 11 Innovative solutions GSM EDGE measurements Application Firmware R amp S FS K5 allows the user to perform the most important GSM and EDGE transmitter measure ments at a keystroke Phase frequency error GSM Modulation accuracy EDGE includ ing 95 th percentile and origin offset suppression Power versus time Carrier power Modulation spectrum Transient spectrum Spurious emissions Error power der versus chip for 1xEV DO signal measured with RES FS K Type Designation and or application Aa v b g 2 SN Additionally required options in the R amp S FSP R amp S FS K4 Phase noise measurements Windows re UN h P A Z R amp S FS K5 Modulation and spect
4. 0 14 min within German wireline network rates may vary in other networks wireline and mobile and countries
5. 2 5 ms minimum sweep time in frequency domain 4 14s sweep time in time domain Up to 55 GPIB measurements s in frequency domain including trace transfer Up to 80 GPIB measurements s in time domain including trace transfer Fast ACP measurement routine in time domain Performance Total measurement uncertainty 0 5 dB Displayed average noise level 155 dBm 1 Hz Phase noise 113 dBc 1 Hz at 10 kHz Dynamic range of RMS detector 100 dB Synthesized frequency setting ROHDE amp SCHWARZ x e e 2 e e Pun a The standard in the medium class Features The Spectrum Analyzers R amp S FSP are outstanding for their innovative measure ments and a host of standard functions Instead of a wide choice of options the R amp S FSP offers as standard all the func tions and interfaces expected from a state of the art spectrum analyzer Largest colour display in its class Resolution bandwidths from 1 Hz to 10 MHz Highly selective digital filters and FFT Z Quasi peak detector and EMI bandwidths Z ACP and multicarrier ACP measurements Convenient documentation of results as a hardcopy or file in PC compatible formats Interfaces GPIB Centronics RS 232 C LAN option USB Automatic test routines for measuring TOI OBW phase noise and ACP R Split screen with separate settings and up to 3 traces per scree
6. BO 129 8394 02 Rugged Case carrying handle factory fitted R amp S FSP B1 1129 7998 02 no AM FM Audio Demodulator R amp S FSP B3 1129 6491 02 yes not with R amp S FSP B15 OCXO Reference Frequency R amp S FSP B4 1129 6740 02 yes TV Trigger RF Power Trigger R amp S FSP B6 1129 859 4 02 yes not with R amp S FSP B21 nternal Tracking Generator 9 kHz to 3 GHz I O modulator for all R amp S FSP models R amp S FSP BI 1129 6991 02 yes External Generator Control for all R amp S FSP models R amp S FSP B10 1129 7246 03 yes Pulse Calibrator for R amp S FSP R amp S FSP B15 1155 1006 02 yes not with R amp S FSP B3 required for R amp S FS K72 K73 LAN Interface 100BT for all R amp S FSP models with Windows XP 1164 4391 xx R amp S FSP B16 1129 8042 03 yes 10 R amp S FSP Spectrum Analyzer Order designation Type Order No Retrofittable Remarks Removable Flash Disk R amp S FSP B18 1163 0892 03 no Second Flash Disk for R amp S FSP B18 R amp S FSP B19 1163 1124 03 R amp S FSP B18 required Extended Environmental Specification R amp S FSP B20 1155 1606 06 no LO IF Ports for External Mixers R amp S FSP B21 1155 1758 03 yes not with R amp S FSP B6 only for R amp S FSP40 Electronic Attenuator 0 dB to 30 dB 5 dB steps integrated preamplifier for R amp S FSP B25 1129 7746 03 yes R amp S FSP3 and R amp S FSP7 Trigger Port for R amp S FSP for in
7. R amp S is a registered trademark of Rohde amp Schwarz GmbH amp Co KG Trade names are trademarks of the owners Printed in Germany Pe as PD 0758 1206 12 Spectrum Analyzer R amp S FSP Version 09 01 February 2005 Data without tolerance limits is not binding Subject to change The Spectrum Analyzers R amp S FSP Unparalleled range of functions Highest measurement speed Maximum precision With the R amp S FSP family the well known advantages of the Rohde amp Schwarz high end analyzers have been systematically integrated into the medium class analyzers The R amp S FSP sets the standard for the medium class regarding the vital criteria of functionality measurement speed and accuracy The use of innovative techniques such as a highly integrated front end and fully digital signal processing in the back end together with ASICs developed by Rohde amp Schwarz has resulted in a product that features top class specifications h reliability AXA edium class Function Option Highly selective digital filters from 10 Hz to 100 kHz Fast FFT filters from 1 Hz to 30 kHz Channel filter 100 Hz to 5 MHz OP detector amp EMI bandwidths 200 Hz 9 kHz 120 kHz 2 5 ms sweep time in frequency domain 1 us sweep time in time domain Time selective spectrum analysis with gating GPIB interface IEEE 488 2 USB interface RS 232 C serial interface 9 pin D sub VGA output 15 pin D sub PC compatible scree
8. and ACPR measurements on narrowband systems such as IS136 or PDC as well as on wideband systems such as IS95 or WCDMA Phase Noise Measurement Software R amp S FS K4 enhances the Spectrum Analyzer R amp S FSP to form a phase noise tester CCDF analysis The R amp S FSP is the first spectrum ana lyzer to offer statistical analysis of signals by means of the complementary cumula tive distribution function CCDF as stan dard and at an impressively high speed The R amp S FSP furnishes in only 250 ms the exact CCDF characteristic average and peak power as well as the crest fac tor covering 1 million measured values ACPR measurements Adjacent channel power ratio ACPR measurements which many mobile radio standards stipulate for components and devices are implemented in the R amp S FSP by means of automatic test rou tines All settings measurements and fil ters required for a selected standard are activated at a keystroke In addition to a large number of preprogrammed stan dards the channel width and channel spacing can be individually selected Owing to the excellent dynamic range lowest phase noise in its class and the RMS detector the R amp S FSP sets the standard in the medium class also for ACPR measurements Phase noise mea surement with the R amp S FSP CCDF of a WCDMA signal Center 2 225 GHz dB Mean Pwr 20 dB Complementary Cumulative Distra gt u tion F nction Samples 1000000 AC P
9. digital filters with a sweep time 2 5 times faster than comparable analog filters the R amp S FSP will also prove beneficial in the day to day tasks of product development Performance Modern communication systems should provide optimum spectral efficiency at high data rates For the 3rd generation of CDMA mobile radio systems currently under development this is achieved through functions such as among other things by high precision power control The R amp S FSP is the ideal partner in development and production featuring low uncertainty in level measurement as well as excellent RF characteristics 0 5 dB total measurement uncertainty allows higher tolerances for the DUT thus increasing production yield 0 07 dB linearity uncertainty 1 c is ideal for precise measurements for example of gain control and ACPR RMS detector with gt 100 dB dynamic range measures power fast and accu rately irrespective of the signal shape almost like a thermal power sensor The displayed average noise level of typ 7155 dBm 1 Hz is attained with out the use of preamplifiers and thus without any reduction in dynamic range Typ 145 dBc 1 Hz phase noise at 10 MHz offset offers optimum condi tions for ACPR measurements on WCDMA systems Resolution bandwidths of up to 100 kHz are fully digital and provide in addition to high selectivity an ideal basis for accurate adjacent channel power measu
10. 28 Output voltage high lt 1 4 V low 20 7 V Trigger port connector 25 pin sub D female Frequency range extension 20 Hz R amp S FSP B29 Frequency range 20 Hz to Taa Frequency response 9 kHz 1 dB Displayed average noise level 0 dB RF attenuation RBW 10 Hz VBW 1 Hz 20 averages trace average span 0 Hz termination 50 Q 20 Hz 58 dBm 100 Hz 15 dBm 1 kHz lt 85 dBm DC Power Supply R amp S FSP B30 Input voltage range 10 V to 28 V DC 25 A to 12 5 A Output voltage 120 V to 360 V DC 300 W Current consumption Vy 12 V R amp S FSP without options default settings R amp S FSP3 typ 6A R amp S FSP 30 typ 8A Operating temperature range 0 C to 50 C Storage temperature range 40 C to 70 C Dimensions in mm W x H x D 145 x 154 x 65 Weight 0 6 kg R amp S FSP Spectrum Analyzer 9 Battery Pack R amp S FSP B31 B32 NiMH battery pack with built in load control for all R amp S FSP and R amp S ESPI models with options R amp S FSP B1 and R amp S FSP B30 Input voltage of battery pack 10 V to 28 V DC Input voltage power supply battery charge 24 V DC max 3 A Output voltage Battery operation 13 2 V DC 200 Wh Bypass operation 10 V to 28 V DC 10 A Typical operating times R amp S F
11. 41096 30 Shape factor 60 dB 3 dB 100 kHz 5 1 Gaussian filters 300 kHz to 3 MHz 15 1 4 pole synchronously tuned filters 10 MHz TA Shape factor 60 dB 6 dB EMI bandwidths 5 1 Video bandwidths 1 Hz to 10 MHz in 1 3 sequence FFT filter N 4 Bandwidths 1 Hz to 30 kHz 3 dB in 1 3 sequence Bandwidth accuracy 596 nominal Shape factor 60 dB 3 dB 2 5 1 nominal Channel filter 100 200 300 500 Bandwidths 1 1 5 2 24 2 7 3 3 4 4 45 5 6 85 9 10 12 5 14 15 16 18 RRC 20 21 24 3 RRC 25 30 50 100 150 192 200 300 500 kHz 1 1 228 1 5 2 3 5 MHz 1 28 RRC 3 84 RRC 4 096 RRC Level TA Display range displayed average noise level to 30 dBm Maximum input level c Y DC voltage 50 V 0V DC voltage with R amp S FSP B29 0V RF attenuation 0 dB CW RF power 20 dBm Pulse spectral density 97 dByV 1 MHz RF attenuation 210 dB CW RF power 30 dBm Max pulse voltage 150 V 50V Max pulse energy 10 us 1 mWs 0 5 mWs 1 dB compression of input mixer 0 dB RF attenuation f gt 200 MHz 0 dBm nominal Intermodulation 3rd order intermodulation Intermodulation free dynamic range level 2 x 30 dBm Af gt 5 x RBW or 10 kHz whichever is larger 20 MHz to 200 MHz gt 70 dBc TOI
12. 6 PD 0757 6433 DC Block 10 kHz to 18 GHz type N R amp S FSE 74 1084 7443 02 GSM EDGE Application Firmware R amp S FS K5 PD 0757 6185 EC IEEE Bus Cable 1 m R amp S PCK 0292 2013 10 AM FM M Measurement Demodulator R amp S FS K7 PD 0757 6685 EC IEEE Bus Cable 2 m R amp S PCK 0292 2013 20 Bluetooth Application Firmware R amp S FS K8 PD 0757 7730 19 Rack Adapter not for R amp S FSP B1 R amp S ZZA478 1096 3248 00 Application Firmware for Noise Figure and Amplifier Measure PD 0758 0839 32 Soft Carrying Case grey R amp S ZZT473 1109 5048 00 ments R amp S FS K30 Printed operating manual German 1093 4820 1 Application Firmware for Phase Noise Measurements PD 0758 2631 32 Printed operating manual English 1093 4820 12 R amp S FS K40 Printed service manual German 1093 4820 8 WCDMA 3GPP Application Firmware R amp S FS K72 K73 K74 PD 0757 7246 Printed service manual English 1093 4820 82 TD SCDMA Test Application Firmware R amp S FS K76 K77 PD 0758 0880 32 Matching Pads 75 CDMA2000 Base Station Test Application Firmware PD 0758 1712 32 D m RRSSRAM 0358 5414 02 1xEV DO Base Station Test Application Firmware R amp S FS K82 K84 Series Resistor 25 0 R amp S RAZ 0358 5714 02 Mobile Station Test Application Firmware PD 0758 1729 32 SWR Bridge 5 MHz to 3 GHz R amp S ZRB2 0373 9017 52 R amp S9FS K83 R amp S9FS K85 SWR Bridge 40 kHz to 4 GHz R amp S ZRC 1039 9492 52 WLAN Application Firmware R amp S FSO K91 PD 0758 1435 12
13. B Linear level display 70 71 nV to 7 07 V in steps of 1 Units of level scale dBm dBmV dBuV dBpA dBpW log level display mV UV mA uA pW nW linear level display Max uncertainty of level measurement At 128 MHz 30 dBm RF attenuation 10 dB RBW 10 kHz ref level 20 dBm 0 2 dB o 0 07 dB R amp S FSP Spectrum Analyzer 5 Frequency response 50 kHz lt 0 5 1 0 dB 50 kHz to 3 GHz 0 5 dB o 0 17 dB 3 GHz to 7 GHz lt 2 dB o 0 7 dB 7 GHz to 13 6 GHz 2 5 dB 13 6 GHz to 30 GHz E E 3 dB 30 GHz to 40 GHz E i lt 4 dB Frequency response with option R amp S FS P B25 switched on preamplifier electronic attenuator 10 MHz to 3 GHz 1 dB o 0 33 dB 3 GHz to 7 GHz 2 dB o 0 7 dB Attenuator 0 2 dB o 0 07 dB Reference level switching 0 2 dB o 0 07 dB Display nonlinearity LOG LIN S N gt 16 dB RBW x100 kHz 0 dB to 70 dB 0 2 dB o 0 07 dB 10 dB to 90 dB 0 5 dB o 0 17 dB RBW 2300 kHz 0 dB to 50 dB 0 2 dB c 0 07 dB 50 dB to 70 dB 0 5 dB o 0 17 dB Bandwidth switching uncertainty ref to RBW 10 kHz 10 Hz to 100 kHz 0 1 dB o 0 03 dB 300 kHz to 10 MHz 0 2 dB o 0 07 dB 1Hzto 3 kHz FFT 0 2 dB o 0 03 dB Total measurement uncertai
14. B3 3 5 mm mini jack 6 R amp S FSP Spectrum Analyzer Output impedance 10 Q Open circuit voltage up to 1 5 V adjustable Inputs and outputs rear panel IF 20 4 MHz Zout BU Q BNC female Level RBW lt 30 kHz FFT 10 dBm at reference level mixer level gt 60 dBm RBW 2100 kHz 0 dBm at reference level mixer level 60 dBm Reference frequency Output BNC female Output frequency 10 MHz Level 0 dBm nominal Input 10 MHz Required level 0 dBm into 50 Q Others Power supply for noise source BNC female 0 V and 28 V switchable max 100 mA External trigger gate input BNC female gt 10 kO Trigger voltage 1 4 V TTL IEC IEEE bus remote control interface to IEC 625 2 IEEE 488 2 A Command set SGP 1997 0 Connector 24 pin Amphenol female Interface functions SH1 AHT T6 L4 SR1 RL1 PP1 DC1 DT1 CO Serial interface RS 232 C COM 9 pin sub D connector Printer interface parallel Centronics compatible Mouse connector PS 2 female Connector for ext monitor VGA General data 15 pin sub D connector C p A oO Display 21cm TFT colour display 8 4 Resolution 640 x 480 pixels VGA resolution Pixel failure rate 2x 10 Mass memory 1 44 MByte 3 disk drive built in hard disk Data storage 2500 instrument settings and traces
15. Bm 22 GHz to 30 GHz 115 dBm _ typ 123 dBm 13 6 GHz to 20 GHz 120 dBm typ 128 dBm 20 GHz to 30 GHz _ lt 120 dBm typ 128 dBm 30 GHz to 40 GHz lt 112 dBm typ 120 dBm Displayed average noise level with preamplifier on option R amp S FSP B25 10 MHz to 2 GHz lt 152 dBm 2 GHz to 7 GHz Immunity to interference lt 150 dBm a Image frequency gt 70 dB Intermediate frequency f lt 3 GHz gt 70 dB Spurious responses f gt 1 MHz without input signal 0 dB attenuation 103 dBm Other spurious with input signal mixer level 10 dBm Af gt 100 kHz f lt 7 GHz 70 dBc f lt 13 6 GHz 64 dBc f 30 GHz 56 dBc Level display Screen 501 x 400 pixels one diagram max two diagrams with independent settings Logarithmic level scale 10 dB to 200 dB in steps of 10 dB Linear level scale 1096 of reference level per level division 10 divisions Traces max 3 with two diagrams on screen max 3 per diagram Trace detector max peak min peak auto peak sample quasi peak average RMS Trace functions clear write max hold min hold average Number of test points 501 selectable in steps of approx factor 2 125 to 8001 Setting range of reference level Logarithmic level display 130 dBm to 30 dBm in steps of 0 1 d
16. High Power Attenuators 100 W R amp S FSP K90 3 6 10 20 30 dB R amp S RBU100 073 8495 XX R amp S FSx K92 K93 WiMAX Application Firmware PD 5213 8550 32 XX 03 06 10 20 30 High Power Attenuators 50 W 3 6 10 20 30 dB R amp S RBUSO 1073 8695 XX XX 03 06 10 20 30 For R amp S FSP30 Test Port Adapter 3 5 mm male T 1021 0529 00 Test Port Adapter N male 1021 0541 00 Microwave Measurement Cable and R amp S FS 715 1046 2002 02 Adapter Set For R amp S FSP40 Test Port Adapter K male gt 036 4802 00 Test Port Adapter N male 1036 4783 00 Test Port Adapter 2 4 mm female R amp S FSE Z5 088 1627 02 Connectors Probe power connector 3 pin 065 9480 00 Taken into account in device function RF INPUT 75 Q Product brochure see PD 0758 1206 12 and at www rohde schwarz com search term FSP ROHDE amp SCHWARZ www rohde schwarz com Europe Africa Middle East 491805124242 or 4989412913774 customersupport rohde schwarz com North America 1 888 TEST RSA 1 888 837 8772 customer support rsa rohde schwarz com Latin America 1 410 910 7988 customersupport la rohde schwarz com Asia Pacific 6565130488 customersupport asia rohde schwarz com R amp S is a registered trademark of Rohde amp Schwarz GmbH amp Co KG Trade names are trademarks of the owners gt Printed in Germany as PD 0758 1206 22 R amp S FSP Spectrum Analyzer Version 06 00 May 2008 Data without tolerance limits is not binding Subject to change
17. NORM 1MHz 3MHz 434us 0 200MHz 20dBm 10dB 0dB NORM 30kHz 100kHz 1ms 0 300MHz 20dBm 10dB 0dB NORM 30kHz 100kHz 1ms 0 Remote control of the R amp S FSP via IEC IEEE bus in list mode cuts down on measurement time List mode In the List mode the user only has to enter a few IEC IEEE bus commands to perform measurements on up to 100 fre quencies with different instrument set ups in each case A single command con figures the list and frequency band widths measurement time reference level and RF attenuation can be set inde pendently of each other The SENSE LIST POWER RESULT query for example simultaneously transfers all measurement results to the process con troller after the list has been processed This feature reduces the time required for transfer via the IEC IEEE bus In conjunc tion with the very high measurement speed of the R amp S FSP it also allows the generation of time saving test routines in production applications The optional Trigger Port R amp S FSP B28 allows idle times between the different settings to be minimized Electronic attenuator for high production throughput The optional Electronic Attenuator R amp S FSP B25 supplements the standard mechanical attenuator and provides a wear and tear free setting range of 30 dB in 5 dB steps The option does away with frequent switching of the mechanical attenuator as required for high through put in production and so increase
18. SP without options R amp S FSP3 2h R amp S FSP30 1 5h Charging time 5 hat 25 C Operating temperature range discharging 0 C to 50 C Operating temperature range charging 10 C to 40 C Storage temperature range lt 1 year 20 C to 35 C Storage temperature range lt 1 month 20 C to 55 C Dimensions W x H x D 400 mm x 134 mm x 42 mm Weight 3 7 kg AC adapter R amp S FSP B31 only Input voltage range 100 V to 240 V AC 10 Input frequency range 50 Hz to 60 Hz 5 Input power 140 VA Output voltage 24V Output current 3A Operating temperature range 0 C to 50 C Storage temperature range 20 C to 70 C Dimensions W x H x D 132 mm x 58 mm 30 mm Weight 0 3 kg Ordering information Order designation Type Order No Spectrum Analyzer 9 kHz to 3 GHz R amp S FSP3 1164 4391 03 Spectrum Analyzer 9 kHz to 7 GHz R amp S FSP7 1164 4391 07 Spectrum Analyzer 9 kHz to 13 6 GHz R amp S FSP 13 1164 4391 13 Spectrum Analyzer 9 kHz to 30 GHz R amp S FSP30 1164 4391 30 Spectrum Analyzer 9 kHz to 40 GHz R amp S FSP40 1164 4391 40 Accessories supplied Power cable compact manual CD ROM with operating manual and service manual R amp S FSP30 test port adapter with 3 5 mm female 1021 0512 00 and N female 1021 0535 00 connector R amp S FSP40 test port adapter with K female 1036 4790 00 and N female 1036 4777 00 connector Options Order designation Type Order No Retrofittable Remarks Options Delete Manuals R amp S FSP
19. Test Equipment Solutions Datasheet Test Equipment Solutions Ltd specialise in the second user sale rental and distribution of quality test amp measurement T amp M equipment We stock all major equipment types such as spectrum analyzers signal generators oscilloscopes power meters logic analysers etc from all the major suppliers such as Agilent Tektronix Anritsu and Rohde amp Schwarz We are focused at the professional end of the marketplace primarily working with customers for whom high performance quality and service are key whilst realising the cost savings that second user equipment offers As such we fully test amp refurbish equipment in our in house traceable Lab Items are supplied with manuals accessories and typically a full no quibble 2 year warranty Our staff have extensive backgrounds in T amp M totalling over 150 years of combined experience which enables us to deliver industry leading service and support We endeavour to be customer focused in every way right down to the detail such as offering free delivery on sales covering the cost of warranty returns BOTH ways plus supplying a loan unit if available and supplying a free business tool with every order As well as the headline benefit of cost saving second user offers shorter lead times higher reliability and multivendor solutions Rental of course is ideal for shorter term needs and offers fast delivery flexibility try before you buy zero capital expend
20. ainty of 0 5 dB the R amp S FSP undisputedly ranks at the top way ahead of other medium class analyzers Sweeps s Sweeps s Span 10 MHz Span 0 Hz Sweep time 2 5 ms sweep time 100 us Binary IEEE 754 format 55 80 Measurement speed on GPIB interface with transfer of trace data Settings DISPLAY OFF DEFAULT COUPLING SINGLE TRACE 501 POINTS 04 0 2 Linearity uncertainty in dB 0 6 60 70 80 g dB below reference leve Display linearity with lt 100 kHz resolution bandwidth measurement on 30 devices for production Spectrum Analyzer R amp S FSP 9 Innovative solutions Measurement routines TOI OBW The R amp S FSP offers fast routines for a multitude of typical measurement tasks which make result postprocessing super fluous by supplying the desired data directly Determination of TOI Z Occupied bandwidth OBW Burst power with peak average and RMS indication as well as standard deviation Modulation depth of AM signals Phase noise Bandwidth marker Of course these functions can also be used via the fast GPIB interface 10 Spectrum Analyzer R amp S FSP Measurement of TOI Measurement of burst power top Determination of OBW bottom Measurement of modulation depth of AM signal an SEE EE Tel I A WW NH o A Input command SENSE LIST POW 100MHz 0dBm 10dB 10dB
21. ce level 20 dBm RBW 30 kHz IF input front lt 1dB Inputs and outputs front LO output IF input SMA female 50 Q IF input SMA female 50 Q Electronic Attenuator R amp S FSP B25 only for R amp S FSP3 and R amp S FSP7 Frequency Frequency range 10 MHz to 7 GH RI Input attenuator range mechanical 0 dB to 75 dB in 5 dB steps Electronic attenuation range 0 dB to 30 dB in 5 dB steps Preamplifier 20 dB switchable Displayed average noise level with preamplifier on 0 dB RF attenuation RBW 10 Hz VBW 1 Hz 20 averages trace average span 0 Hz termination 50 Q 10 MHz to 2 GHz lt 152 dBm 2 GHz to 7 GHz lt 150 dBm Intermodulation with electronic attenuator on 3rd order intermodulation intermodulation free dynamic range level x 30 dBm Af gt 5 x RBW or 10 kHz whichever is larger 20 MHz to 200 MHz gt 74 dBc TOI gt 7 dBm 200 MHz to 3 GHz gt 80 dBc TOI gt 10 dBm 3 GHz to 7 GHz gt 84 dBc TOI gt 12 dBm Max deviation of level measurement 128 MHz 30 dBm RF attenuation 10 dB RBW 10 kHz ref level 20 dBm preamplifier on lt 0 2 dB o 0 07 dB Electronic attenuator lt 0 2 dB o 0 07 dB Frequency response with preamplifier electronic attenuator 10 MHz to 3 GHz 1 0 dB o 0 33 dB 3 GHz to 7 GHz 2 dB c 0 7 dB Trigger Port R amp S FSP B
22. dication of trigger conditions R amp S FSP B28 1162 9915 02 yes Frequency Range Extension 20 Hz for R amp S FSP3 7 R amp S FSP B29 1163 0663 07 no Frequency Range Extension 20 Hz for R amp S FSP 13 30 R amp S FSP B29 1163 0663 30 no Frequency Range Extension 20 Hz for R amp S FSP 40 R amp S FSP B29 1163 0663 40 no DC Power Supply for Spectrum Analyzers R amp S FSP R amp S FSP B30 1155 1158 02 yes Battery Pack for Spectrum Analyzers R amp S FSP R amp S FSP B31 1155 1258 02 yes R amp S FSP B1 and R amp S FSP B30 required Spare Battery Pack for Spectrum Analyzers R amp S FSP R amp S FSP B32 1155 1506 02 yes R amp S FSP B31 required Demodulation Hardware and Memory Extension R amp S FSP B70 1157 0559 02 yes required for R amp S FS K72 K73 R amp S FSP B15 required Software GSM EDGE Application Firmware Mobile R amp S FS K5 1141 1496 02 AM FM M Measurement Demodulator R amp S FS K7 1141 1796 02 Application Firmware for Bluetooth Measurements R amp S FS K8 1157 2568 02 Power Sensor Measurements R amp S FS K9 1157 3006 02 supports R amp S NRP Z11 Z21 with R amp S NRP Z4 USB con nector Application Firmware for Noise Figure and Gain Measurements R amp S FS K30 1300 6508 02 Preamplifier R amp S FSP B25 recommended Application Firmware for Phase Noise Measurements R amp S FS K40 1161 8138 02 3GPP BTS Node B FDD Application Fir
23. el deviation of lt 0 2 dB in the range 0 dB to 70 dB As they are implemented as ASIC functions their great precision is attained without any reduction in measurement speed The complementary cumula tive distribution function CCDF describes the probability of a signal power exceeding a specific usually the average power CCDF analysis is indis pensable for determining the optimal transmitting power for CDMA signals assuming that clipping over known short intervals is tolerable The R amp S FSP with its dedicated CCDF measurement routine furnishes 10 single values in only 250 ms thus enabling extremely accurate statistical analysis even of rarely occur ring signal peaks This analysis function which is becoming more and more important has been implemented for the first time in the Spectrum Analyzer R amp S FSP as a fast and cost effective solution based on ASICs The platform Excellent specifications such as those of the R amp S FSP require a high grade and service friendly platform All the modules are optimally shielded and easy to exchange and are accommodated in a lightweight but stable frame A powerful low noise fan in conjunction with low power consumption of 70 VA to 150 VA depending on model makes for high reli ability A 2 year calibration interval excluding the reference frequency is offered with the R amp S FSP Fit for the future Owing to its modular design
24. er at least not valid from 9 kHz to 9 kHz The specified level accuracy of the tracking generator is valid under the following conditions RF attenuation 2 20 dB and sweep time 22000 ms Frequency Frequency range 9 kHz to 3 GHz Frequency offset Setting range 150 MHz Resolution 1 Hz Spectral purity dBc 1 Hz SSB phase noise f 500 MHz carrier offset 100 kHz Normal mode typ 90 With FM modulation on typ 70 Level Level setting range 30 dBm to 0 dBm in steps of 0 1 dB Level setting range with AM 30 dBm to 6 dBm in steps of 0 1 dB Max deviation of output level 128 MHz 0 dBm 1 dB Frequency response Output level 0 dBm 100 kHz to 2 GHz 1 dB Output level 0 dBm to 25 dBm 9 kHz to 3 GHz 3 dB Dynamic range Attenuation RBW 1 kHz f gt 10 MHz typ 110 dB Spurious Harmonics output level 10 dBm typ 30 dBc Nonharmonics output level 0 dBm typ 30 dBc Modulation Modulation format external 1 0 AM FM FM DC PM ASK FSK AM f gt 10 MHz Modulation depth 0 to 99 Modulation frequency range 0 Hz to 1 MHz FM f gt 10 MHz Frequency deviation 0 Hz to 20 MHz Modulation frequency range 0 Hz to 100 kHz 1 0 modulation f gt 10 MHz 0 Hz to 30 MHz typ 1 dB Inputs and outputs front panel RF output N female 50 Q VSWR typ 2 1 Inputs and outpu
25. gt 5 dBm 200 MHz to 3 GHz gt 74 dBc TOI gt 7 dBm typ 10 dBm 3 GHz to 7 GHz gt 80 dBc TOI gt 10 dBm typ 15 dBm 7 GHz to 13 6 GHz gt 80 dBc TOI gt 10 dBm 13 6 GHz to 30 GHz _ gt 76 dBc TOI gt 8 dBm gt 80 dBc TOI gt 10 dBm 30 GHz to 40 GHz gt 80 dBc TOI gt 10 dBm With optional Electronic Attenuator R amp S FSP B25 switched on 20 MHz to 200 MHz gt 74 dBc TOI gt 7 dBm 200 MHz to 3 GHz gt 80 dBc TOI gt 10 dBm 3 GHz to 7 GHz gt 84 dBc TOI gt 12 dBm 4 R amp S FSP Spectrum Analyzer Second harmonic intercept point SHI lt 100 MHz typ 25 dBm 100 MHz to 1 5 GHz typ 35 dBm 1 5 GHz to 7 GHz typ 80 dBm 7 GHz to 13 6 GHz typ 80 dBm 13 6 GHz to 30 GHz typ 80 dBm 30 GHz to 40 GHz typ 80 dBm Displayed average noise level 0 dB RF attenuation RBW 10 Hz VBW 1 Hz 20 averages trace average span 0 Hz termination 50 Q Frequency 9 kHz 95 dBm 100 kHz 100 dBm 1 MHz 120 dBm typ 125 dBm 10 MHz to 1 GHz lt 142 dBm typ 145 dBm 140 dBm typ 145 dBm 1 GHz to 3 GHz lt 140 dBm typ 145 dBm 138 dBm typ 143 dBm 3 GHz to 7 GHz _ lt 138 dBm typ 143 dBm lt 135 dBm typ 140 dBm 7 GHz to 13 6 GHz 132 dBm typ 138 dBm 13 6 GHz to 22 GHz lt 120 dBm _ typ 128 d
26. ic bandwidth measurement with n dB down function Tolerance lines with PASS FAIL as sessment The R amp S FSP B6 option makes the Spectrum Analyzers R amp S FSP suitable for analog TV measurement applications and provides a settable RF level trigger for measurements on pulsed RF signals that are used in TDMA transmission systems 14 Spectrum Analyzer R amp S FSP through custom made options Complete measurement solutions Environmental compatibility Fast and easy disassembly Small number of materials Compatibility of materials Easy identification of substances through appropriate marking plastics Recycling of enclosure DESIGN WINNER Open for the PC world 1998 F PC compatible screenshots no E conversion software needed ML Windows printer support USB interface for connecting PC lt 2 peripherals LabWindows driver LabView driver SCPI compatible R amp S FSE FSIO compatible GPIB command set Customized training 4 Solution oriented consulting Application notes 2 year calibration cycle and much more ho guessing games Spectrum Analyzer R amp S FSP 15 Specifications in brief of the R amp S FSP family Frequency range 9 kHz to 3 GHz 9 kHz to 7 GHz 9 kHz to 13 GHz 9 kHz to 30 GHz 9 kHz to 40 GHz Spectral purity Residual FM typ 3 Hz Span gt 10 Hz 2 5 ms to 16000 s S
27. ical values for SSB phase noise reference to 1 Hz bandwidth Offset f 3 GHz fn 7 GHz fin 13 GHz f n 22 GHz fin 26 GHz fin 40 GHz 100 Hz 74 dBc 67 dBc 61 dBc 57 dBc 55 dBc 52 dBc 1kHz 100 dBc 94 dBc 88 dBc 84 dBc 82 dBc 79 dBc 10 kHz 108 dBc 104 dBc 98 dBc 94 dBc 92 dBc 91 dBc 100 kHz 108 dBc 106 dBc 100 dBc 96 dBc 94 dBc 92 dBc 1 MHz 118 dBc 118 dBc 112 dBc 108 dBc 106 dBc 102 dBc Typ SSB phase noise vs offset ieee i es fin in GHz 0 Bi SA mi N MS 1 T 7 a zd Eod S ag e E DUX mS H So NON e DT I ur S 30 SNI a e N Im gt 4 __ X I E ME TIN JN T e 100 E nn e Tr I i E B MD gt ANA XAN E 5 110 p 5 c r e 120 130 100 Hz 1 kHz 10 kHz 100 kHz 1MHz SSB phase noise in dBc 1 Hz Offset frequency Typ SSB phase no ise vs frequency 15 20 Frequency in GHz 25 30 40 R amp S FSP Spectrum Analyzer 3 Sweep time Span 210 Hz 2 5 ms to 16000 s Max deviation 1 Span 0 Hz 1 us to 16000 s Resolution 125 ns Resolution bandwidths Bandwidths 10 Hz to 10 MHz 3 dB in 1 3 sequence EMI bandwidths 200 Hz 9 kHz 120 kHz 6 dB Bandwidth accuracy 100 kHz 396 300 kHz to 3 MHz 1096 10 MHz
28. it re lower risk and off balance sheet accounting Both second user and rental improve the key business measure of Return On Capital Employed We are based near Heathrow Airport in the UK from where we supply test equipment worldwide Our facility incorporates Sales Support Admin Logistics and our own in house Lab All products supplied by Test Equipment Solutions include No quibble parts amp labour warranty we provide transport for UK mainland addresses Free loan equipment during warranty repair if available Full electrical mechanical and safety refurbishment in our in house Lab Certificate of Conformance calibration available on request Manuals and accessories required for normal operation Free insured delivery to your UK mainland address sales Support from our team of seasoned Test amp Measurement engineers 1509001 quality assurance Test equipment Solutions Ltd Unit 8 Elder Way Waterside Drive Langley Berkshire SL3 6EP T 44 0 1753 596000 F 44 0 1753 596001 Email info TestEquipmentHQ com Web www TestEquipmentHQ com Spectrum Analyzer R amp S FSP Features 21 cm TFT colour display 1Hzto 10 MHz RBW Z RMS detector for fast and reproducible measurements on digitally modulated signals Z Measurement routines for TOI ACPR OBW amplitude statistics multicarrier ACP EMI bandwidths and quasi peak detector The medium et ss standard Speed
29. lay switched off In the zero span mode 80 measurements s are possible This characteristic makes the R amp S FSP by far the fastest spectrum analyzer on the GPIB interface Valuable time can be saved in production boosting throughput enormously The R amp S FSP thus supports you in getting your products more cost effective on the market 0 2 dB maximum linearity uncertainty All modern mobile radio systems achieve high spectral efficiency through precise control of transmitter output power or other means The correct functioning of gain control which may be as much as 70 dB depending on the system is checked against the nominal value in a large number of individual measure ments Featuring a maximum linearity uncer tainty of only 0 2 dB and fast power mea surement routines especially for digitally modulated signals the R amp S FSP is the ideal choice wherever the reduction of the test time and the number of rejects is of primary importance 0 5 dB total measurement uncertainty Measurement uncertainty can be split into the part from the instrument and that introduced by the test setup With lower uncertainty of the spectrum analyzer greater tolerances can be allowed for the test setup If the lower uncertainty of the analyzeris utilized to allow for higher DUT tolerances the result will be a marked reduction of manufacturing rejects an advantage that pays off immediately With a total measurement uncert
30. mware R amp S FS K72 154 7000 02 R amp S FSP B15 and B70 required 3GPP UE FDD Application Firmware R amp S FS K73 154 7252 02 R amp S FSP B15 required R amp S FSP B70 recommended 3GPP HSDPA BTS Application Firmware R amp S FS K74 1300 7156 02 R amp S FS K72 required 3GPP TD SCDMA BTS Application Firmware R amp S FS K76 300 7291 02 3GPP TD SCDMA UE Application Firmware R amp S FS K77 300 8100 02 CDMA2000 IS 95 1xEV DV BTS FDD Application Firmware R amp S FS K82 157 2316 02 CDMA2000 1xEV DV MS Application Firmware R amp S FS K83 157 2416 02 CDMA2000 1xEV DO BTS Application Firmware R amp S FS K84 157 2851 02 CDMA2000 1xEV DO MS Application Firmware R amp S FS K85 300 6689 02 WLAN 802 11a TX Measurements Application Firmware R amp S FSP K90 300 6650 02 WiBro IEEE 802 16 OFDMA Measurements Application Firmware R amp S FSP K93 308 5500 02 The Bluetooth word mark and logos are owned by the Bluetooth SIG Inc and any use of such marks by Rohde amp Schwarz is under license CDMA2000 is a registered trademark of the Telecommunications Industry Association TIA USA R amp S FSP Spectrum Analyzer 11 Recommended extras Related data sheets Designation Type Order No Title Order No Headphones 0708 9010 00 TV Trigger RF Power Trigger R amp S FSP B
31. n Editable limit lines including PASS FAIL indication Fast measurements in the time do main minimum sweep time 1 us Gated sweep for measurements on TDMA signals 2 Spectrum Analyzer R amp S FSP In addition the R amp S FSP features the fol lowing unique attributes as standard Z RMS detector for fast and reproduc ible power measurements on digitally modulated signals in frequency and time domain Statistical measurement functions for determining crest factor and CCDF complementary cumulative distribu tion function Featuring such a wealth of functions the R amp S FSP offers state of the art spectrum analysis at an extremely attractive price performance ratio Speed Time is a finite resource so high mea surement speed is indispensable for com petitiveness and cost effective testing Here too the new R amp S FSP offers char acteristics that make it top of the class 4 Up to 55 measurements s on GPIB interface including trace transfer of 501 binary data 4 80 measurements s on GPIB interface in zero span mode including trace transfer of 501 binary data Minimum sweep time of 2 5 ms FSP SPECTRUM ANALYZER kHz 30 GHz 1 us time domain measurements 4 Unique fast ACP mode for high speed ACPR measurements in time domain using the standard compliant test filters List mode for fast selective power measurements With 100 measurements s in manual operation and
32. ndustry Association TIA USA Initial Carrier Frequency Tolerance 335 9 Hz 1 093 kHz Status PASSED nuer age 633 8 Hz Spectrum Analyzer R amp S FSP Measurement of initial carrier fre quency tolerance of Bluetooth signal with R amp S FS K8 Simultaneous power versus time measurement on eight slots of EDGE signal Code domain power measurement ver sus slot 13 Innovative solutions Scalar network analysis in wide dynamic range and at any frequency offset The optional Internal Tracking Generator R amp S FSP B9 up to 3 GHz and External Generator Control R amp S FSP B10 extend the R amp S FSP spectrum analyzers to sca lar network analyzer functionality The gain frequency response insertion and return loss are measured using a selec tive method in a wide dynamic range without any influence from the harmon ics or spurious of the generator The Inter nal Tracking Generator R amp S FSP B9 can be used in all R amp S FSP models and cov ers the frequency range from 9 kHz to 3 GHz A frequency offset of 150 MHz can be set for measurements on frequency converting modules The track ing generator can be broadband modu lated by an external I Q baseband signal The R amp S FSP B10 option uses comme the functionality of the internal tracking generator can be utilized Normalization with interpolation also for reflection measurements with open and short Automat
33. nshots on floppy disk or hard disk Measurement speed manually up to 100 measurements s Measurement speed GPIB up to 80 measurements s SCPI compatible GPIB command set R amp S FSE FSIQ compatible GPIB command set 856XA B compatible command set Fast ACP measurements in time domain CGDF measurement functions RMS detector with 100 dB dynamic range 2 year calibration interval Cabinet for portable use AM FM audio demodulator OCXO reference frequency TV trigger RF power trigger Tracking generator External generator control Pulse calibrator LAN interface Extended environmental specification LO IF ports for external mixers Electronic attenuator Trigger port Frequency range extension 20 Hz DC power supply Battery pack spare battery pack Demodulation hardware memory extension Except reference frequency Standard Option B3 B1 B3 B4 B6 B9 B10 B15 B16 B20 B21 B25 B28 B29 B30 1 B32 B70 R amp S ESP Spectrum Analyzer Data Sheet ROHDE amp SCHWARZ Version 06 00 May 2008 Specifications Specifications are valid under the following conditions 15 minutes warm up time at ambient temperature specified environmental conditions met calibration cycle adhered to and total calibration performed Data without tolerances typical values only Data designated nominal applies to design parameters and is not tested Data designated o xx dB is shown as standard deviation
34. nty 50 kHz to 3 GHz signal level 0 dB to 70 dB below reference level S N gt 16 dB RBW lt 100 kHz 95 96 confidence level 0 5 dB Trigger functions Trigger Span 210 Hz Trigger source free run video external IF level Trigger offset 125 ns to 100 s resolution 125 ns min or 1 of offset Span 0 Hz Trigger source free run video external IF level Trigger offset 3 125 ns to 100 s min resolution 125 ns dependent on sweep time Max deviation of trigger offset 125 ns 0 196 x delay time Gated sweep Trigger source external IF level video Gate delay 1 us to 100 s Gate length 125 ns to 100 s min resolution 125 ns or 1 of gate length Max deviation of gate length 125 ns 0 05 x gate length Inputs and outputs front panel RF input N female 50 Q test port system 50 Q test port system 50 O N female N female 3 5 mm female K female VSWR RF attenuation gt 0 dB f lt 3 GHz 1 5 1 f lt 7 GHz 20 1 f 13 GHz 25 1 f 30 GHz 3 0 1 f 40 GHz 3 0 1 Input attenuator 0 dB to 70 dB in 10 dB steps With option R amp S FSP B25 0 dB to 75 dB in 5 dB steps not available Probe power supply 15 V DC 12 6 V DC and ground max 150 mA Keyboard connector PS 2 female for MF2 keyboard AF output only with option R amp S FSP
35. pan O Hz zero stal Resolution bandwidths 10 Hz to 10 MHz FFT filter 1 Hz to 30 kHz channel filter EMI bandwidths Video bandwidths 0000000 Display range DANL up to 30 dBm 1 GHz typ 145 dBm typ 145 dBm 145 dBm typ 145 dBm typ 145 dBm MoH ty Bm yp 145 dBm typ 145 dBm 13 GHz 7138 dBm typ 138 dBm typ 138 dBm ZERER mn ae eon nm 40 GHz i typ 120 dBm Total measurement uncertainty f lt 3 GHz Certified Quality System Certified Environmental System ISO 9001 ISO 14001 DOS REG NO 1954 OM DOS REG NO 1954 UM Spectrum Analyzer R amp S FSP 16 Ordering information Order designation Type Order No Spectrum Analyzer 9 kHz to 7 GHz R amp S FSP7 1164 4391 07 Spectrum Analyzer 9 kHz to 30 GHz R amp S FSP 30 1164 4391 30 Accessories supplied Related data sheets TV Trigger RF Power Trigger R amp S FSP B6 1 PD 0757 6433 PD 0757 6185 GSM EDGE Application Firmware R amp S FS K5 for R amp S FSP Bluetooth Application Firmware R amp S FS K8 PD 0757 7730 WCDMA 3GPP Application Firmware R amp S FS K72 K73 PD 0757 7246 PD 0758 0916 22 Spectrum Analyzer R amp S FSP 17 ROHDE amp SCHWARZ www rohde schwarz com Europe Tel 49 1805 12 4242 e mail customersupport rsv rohde schwarz com North America Tel 1 410 910 7988 e mail customersupport rsa rohde schwarz com Asia Tel 65 68463710 e mail customer service rssg rohde schwarz com
36. rements owing to a maximum bandwidth deviation of 396 how even faster Spectrum Analyzer R amp S FSP 3 High end characteristics Rohde amp Schwarz ASICs Top class performance as offered by the R amp S FSP essentially depends on the extensive use of digital signal processing and large scale integration of compo nents For these demanding tasks Rohde amp Schwarz has developed ASICs tailored to the requirements of signal analysis Key functions such as RMS detection Digital IF filtering Logarithmation CCDF measurement are cast in silicon and are thus faster than conven tional solutions RMS detector The RMS detector a unique feature in all current Rohde amp Schwarz spectrum analyzers quickly yields stable and reproducible results even for complex sig nals such as CDMA By performing a very large number of linear single measure ments followed by power integration the detector avoids the measurement error inherent in conventional analyzers that arises from the averaging of the log video signal The RMS detector of the R amp S FSP measures all modern communi cation signals with unparalleled accuracy and speed 4 Spectrum Analyzer R amp S FSP Logarithmic amplifier The R amp S FSP comes equipped with digi tal resolution filters between 10 Hz and 100 kHz featuring high selectivity and very low bandwidth deviation The filters have an extremely low logarithmic lev
37. reprogrammed NONE standards for ACP NADL IS136 measurements TETRA PDC PHS CDPD CDMA IS9SA FWD CDMA IS95A REV CDMA IS9SC Class FWD CDMA IS9SC Class REV CDMA J STD S FWD CDMA J STD S REV CDMA IS9SC Class 1 FWD CDMA IS9SC Class 1 REV W CDMA 4 896 FWD W CDMA 4 096 REV W CDMA 3GPP FWD W CDMA SGPP REV CDMA 2000 DS CDMA 2888 H 4 CDMA 28808 MCS TD SCDMA for research amp development Spectrum Analyzer R amp S FSP 7 Innovative solutions High measurement speed w With 100 measurements s in manual wf ui operation a minimum sweep time of 2 5 ms and 1 Us zero span as standard 100000 the R amp S FSP is ideal for time critical applications The highly selective fast sweep digital filters featuring analog response allow measurements on pulsed signals as well as the use of the built in frequency counter 10000 Sweep time in ms 1 000 100 The R amp S FSP comes standard with dif v a w am 1000 Resolution bandwidth in Hz ferent filter types for digital resolution bandwidths up to 100 kHz such as Gauss ian filter raised root cosine RRC filter and steep sided channel filters Up to a resolution bandwidth of 30 kHz fast Fou rier transform FFT is available in addi tion In the analyzer FILTER TYPE mode the Gaussian NORMAL filters have
38. rum re GSM EDGE a nos signals R amp S FS K7 AM FM M measurement dem dula al applica R amp S FS K8 Bluetooth transmitter me Sg gt o A R8S FS K9 Power sensor mea e oS supports R amp S NRP Z11 Z21 722 723 724 e j Z51 Z55 Z91 with R amp S NRP Z4 USB adapter Modulation and code domain er meas with FEQ e J H R amp S FS K72 3GPP TS 24 141 on base Su Los R amp S FSP B15 and R amp S FSP B70 QN R amp S FSP B15 slot based measurements R amp S FS K73 ee m w MS C R amp S FSP B70 additionally required for frame ie R amp S FS K74 HSDPA extension for R amp S FS K72 S R amp S FS K76 Modulation and code domain power measurements on TD SCDMA base station signals R amp S FS K77 Modulation and code domain power measurements on TD SCDMA mobile station signals UE Modulation and code domain power measurements in accordance with CDMA2000 1xEV DV ers nes FSRA on base station signals also for measurements on IS95 cdma ne signals Modulation and code domain power measurements on CDMA2000 1xEV DV mobile station efg R amp S FS K83 Signals UB R amp S FS K84 Modulation and code domain power measurements on 1xEV DO base station signals R amp S FS K85 Modulation and code domain power measurements on 1xEV DO mobile station signals UE R amp S FSP K90 WLAN 802 11a Application Firmware Noise figure measurements application firmware functions similar to R amp S FS K3 but remo
39. s the availability and reliability of the measure ment equipment For example the limit of 10 switching operations which Istypical of mechanical attenuators already means a breakdown after approx 6 months at 1 5 switching operations s whereas the Electronic Attenuator R amp S FSP B25 can be switchedany number of times without impairing the specifications The integrated switchable 20 dB pream plifier allows high sensitivity measure ments in the useful frequency range from 10 MHz to 7000 MHz LAN interface With the aid of the optional LAN Interface R amp S FSP B16 the R amp S FSP can be con nected to common networks such as 100Base T so that functions such as file logging on network drives or documenta tion of measurement results via a net work printer are available In addition the R amp S FSP can be remote controlled via LAN which is especially easy with the WindowsXP Remote Desktop function This yields a clear speed advantage over the IEC IEEE bus in particular for the transmission of large data blocks Output FSP 28 3 30 6 38 1 859x 8566 compatible IEC IEEE bus command set In many applications existing test soft ware is to be used in automatic test sys tems alongside new devices For this rea son the R amp S FSP comes standard with an IEC IEEE bus command set that is compatible not only with the R amp S FSEx EST family but also with the spectrum analyzers of the 859x 8566 series
40. standing for its ultra low measurement uncertainty The total measurement uncertainty is less than 0 5 dB Due to this excellent value the use of power meters in routine lab applications very often becomes superfluous and may greater tolerances are possible for DUTs RMS detector The unique RMS detector measures mod ern noise like communication signals with optimal repeatability and stability As there are neither correction factors nor the typical errors caused by averaging of logarithmic trace data the correct aver age power is displayed with high stability for all signal types almost like in mea surements with a thermal power meter Noise figure measurements LE I I c E u xl Owing to its excellent display linearity the R amp S FSP is also ideal for noise figure mea surements The optional Noise Measure ment Software R amp S FS K30 enhances the R amp S FSP to form a noise measurement Noise figure measurement with Noise Measurement Software R amp S FS K30 system offering analyzer specific advan tages see data sheet PD 0758 0839 32 6 Spectrum Analyzer R amp S FSP Phase noise The low phase noise of the R amp S FSP makes it suitable for demanding mea surement tasks both in the vicinity of the carrier typ 113 dBc 1 Hz at 10 kHz and far from the carrier typ 125 dBc 1 Hz at 1 MHz The R amp S FSP is thus optimally equipped for performing spec tral analysis
41. te Preamplifier recommended e g R amp S FSP B25 F R amp S FS K30 controllable for R amp S FSP 3 7 12 Spectrum Analyzer R amp S FSP based measurements Bluetooth signal measure ments Enhanced measurement functionality in line with B uetooth RF Test Specifi cation B uetooth SIG Rev 0 91 Measurement functions Qutput power Adjacent channel power ACP Modulation characteristics Initial carrier frequency tolerance ICTF Carrier frequency drift Simultaneous display of traces and all numerical measurement results Automatic limit value monitoring Ideal for use in development and pro duction of Bluetooth modules Standard 8GPP modulation and code domain power measure ments Adds measurement functions in line with the 3GPP specifications for the FDD mode For BTS Node B signals Application Firmware R amp S FS K72 For CDMA2000 3GPP3 base station signals Application Firmware R amp S FS K82 K84 For UE signals Application Firmware R amp S FS K73 High measurement speed of 4 s measurement 4 Code domain power and CPICH power Code domain power and rho CDMA2000 3GPP2 EVM and PCDE Code domain power versus slot EVM code channel Spectrum emission mask BLUETOOTH is a trademark owned by Bluetooth SIG Inc USA and licensed to Rohde amp Schwarz CDMA2000 is a registered trademark of the Telecommuni cations I
42. the R amp S FSP is optimally equipped to handle all present and future tasks The design takes into account both hardware and firmware extensions to safeguard your investment far into the future Thus you can also rely on your R amp S FSP to meet all requirements that will arise in the years to come Ergonomics and design The R amp S FSP sets the ergonomic stan dard in this class of analyzers The 21 cm 8 4 colour display is the largest and most brilliant in its category Vertical and horizontal rows of softkeys allow even complex measurement tasks to be performed easily Parameters such as fre quency and amplitude are entered by means of dedicated hardkeys and unit keys U e P e VEN EN E 4 d aW d M X N N through innovative solutions Spectrum Analyzer R amp S FSP 5 Innovative solutions Optimum dynamic range ee Mum at 10 Hz RBW the R amp S FSP measures RT ra T N TETER REJIN even small signals accurately without ERN a EE L ER ES EN N using preamplifiers that reduce dynamic EE Satie ER ER IN range Together with the high intercept MP TL TAW TL A pn TT Tar Ta HER BRE DR ES BE point this yields an intermodulation free range of typ 100 dB yet another record H4 4 4 among medium class analyzers HAJE EN ER ER HET E BE BI aS Bad Ultra low measurement uncertainty In the vital frequency range below 3 GHz the R amp S FSP is out
43. the advantage of high sweep speed plus RO excellent resolution At high span RBW OH ratios measurements using FFT can be as M LSD aD wmm 3H pw m M LUE np mmm much as 300 times faster than measure ments with digital filters Comparison of sweep times for 200 kHz span using digital filters or FFT YAT T x ey eu NT ii L illl i Ali Att 20 dn r Center 2 Tx Channel Power 0 01 n Bandwidth Adjacent Channel Lower 6 duo Bandwidth Upper 56 gt Spacing Alternate Channel Lower 57 10 dBc Bandwidth Upper Bpacing Measurement of adjacent channel power in time domain FAST ACP 8 Spectrum Analyzer R amp S FSP Some mobile radio standards such as TETRA and 18136 require RRC filters for power measurement a type of filter already included in the R amp S FSP In addition the R amp S FSP provides channel filters for other analog and digital methods e g cdmaOne AM FM radio and ETS 300 113 Adjacent channel power due to switching can also be mea sured using the channel filters For the common mobile radio standards the R amp S FSP is equipped with test routines fast ACP that allow the adjacent chan nel power in the time domain to be deter mined which reduces measurement time and increases reproducibility 55 measurements per second on GPIB interface The high speed GPIB interface enables up to 55 measurements s including trace data transfer of 501 test points with the disp
44. ts rear panel TG AM IN Vinaxipp 1 V Zin 90 Q BNC female TG Q FM IN Vinaxipp 1 V Zin 90 Q BNC female External Generator Control R amp S FSP B10 Supported signal generators R amp S SME02 03 06 R amp S SMG R amp S SMGL R amp S SMGU R amp S SMH R amp S SMHU R amp S SMIQ02B 02E 03B 03E 04B 06B R amp S SML R amp S SMR20 27 30 40 60 R amp S SMP02 22 03 04 R amp S SMX R amp S SMY R amp S SMT 02 03 06 LAN Interface R amp S FSP B16 Connector rear panel RJ 45 Supported protocols 10Base T IEEE standard 10 Mbit s 802 3 100Base TX IEEE standard 100 Mbit s 802 3u Extended Environmental Specification R amp S FSP B20 Temperature range noncondensing Operating temperature range 0 C to 50 C Permissible temperature range 0 C to 55 C Mechanical resistance Vibration random 8 R amp S FSP Spectrum Analyzer 10 Hz to 300 Hz acceleration 1 9 g rms LO IF ports for external Mixers R amp S FSP B21 R amp S FSP40 only LO level Frequency range 7 GHz to 13 2 GHz Level 15 5 dBm 3 dB IF input IF frequency 404 4 MHz Full scale level 2 port mixer LO output IF input front 20 dBm Level deviation IF level 30 dBm reference level 20 dBm RBW 30 kHz lt 1dB LO output IF input front Full scale level 3 port mixer IF input front 20 dBm Level deviation IF level 30 dBm referen

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instrucciones SATHUNTER  ASUS Transformer Pad TF300T 32GB Blue  ⅯVⅭ-98Ⅾ - Parchem  Edifier Enterprises Canada R251 Speaker System User Manual  Fx,Fy,Fz,Mx,My,Mz  KitchenAid KHM7210WH Use and Care Manual  THE WYLE SCIENTIFIC MAINTENANCE AND SERVICE MANUAL  Mémoire Antonino Pereira Carlos  Help File (PDF: 583 KB)    