Wax pencil Pro directions for use GB

image

Contents

1. First in Dentistry SPLY WAXPENCIL PRO Owner amp Operator s Manual Model No Voltage Frequency 9995337 120V 50 60 Hz 9995338 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safee a 2 Technical Date ee 3 Installation Instructions nennen 4 General Operation eee eeeeeeeeeeeesteeeeetteeees 5 Maintenance meri 6 Troubleshooting cmiicccccconcccccnnnccnnnncono 7 Product Service cccccnncccccnnccncnnoncninnno 8 Declaration of Conformity oooocoiocccionccionccinnnono 9 Warrany sstvapscudatadentaarandeeendaes Back DENSPLY CERAMCO SAFETY FOR PROFESSIONAL USE ONLY Please read these operating instructions carefully before installing or operating this equipment Use indoors only Never operate the unit in close proximity to combustible materials or place materials on top of the unit The unit must be electrically grounded to a three wire electrical outlet or receptacle Unit must be placed in a position that allows the power cord to be easily disconnected from the wall or inlet socket Do not attempt to maintain the unit until you have read and understood this operation manual Do not touch the heater or tip when operating Use pliers to change tips when hot Do not splash the handpieces or control box with water or liquids Keep combustible material away from the pencil Disconnect the line cord before attempting to service the unit Do no
2. or at DENTSPLY Ceramco s option replacing those products included within the warranty which are returned to DENTSPLY Ceramco within the applicable warranty period with shipping charges prepaid and which are determined by DENTSPLY Ceramco to be defective This warranty shall not apply to any product which has been subject to misuse negligence or accident or misapplied or modified or repaired by unauthorized persons or improperly installed INSPECTION Buyer shall inspect the product upon receipt The buyer shall notify DENTSPLY Ceramco in writing of any claims of defects in material and workmanship within thirty days after the buyer discovers or should have discovered the facts upon which such a claim is based Failure of the buyer to give written notice of such a claim within this time period shall be deemed to be a waiver of such claim DISCLAIMER The provisions here in stated DENTSPLY Ceramco sole obligation and exclude all other remedies or warranties expressed or implied including those related to MERCHANTABILITY and FITNESS FOR A PARTICULAR PURPOSE LIMITATION OF LIABILITY Under no circumstances shall DENTSPLY Ceramco be liable to the buyer for any incidental consequential or special damages losses or expenses LIMITATION OF ACTIONS The buyer must initiate any action with respect to claims under the warranty described in the first paragraph within one year after the cause of action has accrued Corporate and Sales Offic
3. 95351 Tip 14 3 pk 11 14 INSTALLATION INSTRUCTIONS Shipping damage should be reported to the carrier as soon as detected UNPACKING Save the box and other packing material for future use in transporting the unit Open the box Carefully unpack and remove the WAX PENCIL PRO from its shipping carton Remove packaging supports Remove plastic bag INSTALLATION The WAX PENCIL PRO shipping carton contains the following One dual power controller with power cord Owner amp operator s manual Two pencils Two side mount pencil holders One free standing pencil tip holder 8 assorted tips one each of tip 2 6 7 8 11 14 and two of 3 WARNING Never operate the Unit in close proximity to combustible materials or place materials on top of the unit Do not use extension cords with this equipment Do not position the unit in a way that blocks access to the power cord inlet socket or the wall outlet A GENERAL OPERATION FUNCTION DESCRIPTIONS Attach the side mount pencil holders by removing the lower front side screw and attach as shown below On Indicator Pencil Tip Temperature Adjust Knob A Pencil Connector A On Off Control A Pencil Connector B Pencil Tip Temperature Adjust Knob B Pencil Holders with Pencils On Off Control B PENCIL TIP HOLDER all FUNCTION OPERATION Connect the power cord to a power circuit Connect the two pencils to its conn
4. e DENTSPLY Austenal DENTSPLY International 570 West College Avenue York PA 17404 0872 USA PH 800 621 0341 FAX 717 849 4712 EU Rep DeguDent GmbH Rodenbacher Chaussee 4 D 63457 Hanau Germany Phone 49 6181 59 57 59 Fax 49 6181 59 59 62 Product Service Office DENTSPLY Ceramco DENTSPLY International 13553 Calimesa Blvd Yucaipa CA 92399 USA PH 909 795 2461 FAX 909 795 5268 equipmentrepair ca dentsply com DENTSPLY Canada 161 Vinyl Ct Woodbridge Ontario LAL 4A3 905 851 5374 PC 9363102 0704 Rev G O 2007 DENTSPLY Ceramco All Rights Reserved Printed in USA
5. ectors and place in holder Push the ON OFF switch for one or both pencils To adjust the pencil temperature turn knob for the desired tip temperature Clockwise increases the temperature MAINTENANCE WARNING This equipment contains dangerous voltages Maintenance and repair work should only be performed by an authorized service technician of DENTSPLY Ceramco To keep the equipment in good working order you should follow the guidelines below Examine the equipment regularly for mechanical damage Do not use solvents or liquid cleaners on the control panel CLEANING Clean the unit at least once a week Clean exterior surfaces with a soft damp cloth using a mild detergent and water DO NOT IMMERSE IN WATER TROUBLESHOOTING Service of this equipment should be done only by qualified personnel Failure to comply may result in personnel injury and or property damage Problem Cause Solution No power to unit Power switch No power Blown fuse Place switch in ON position Check line voltage Check and replace fuse 25 Amp Pencil tip temperature to low Corroded pencil tip Clean pencil holder tip REPLACEMENT PARTS See Accessories in the Technical Data Section PRODUCT SERVICE WARNING This equipment is designed with safety features to protect the operator and must not be modified in any form Only qualified individuals should re
6. pair this piece of equipment Failure to observe these precautions may result in burns or electrical shock Three methods of product service are available Telephone assistance available at the number listed below Return the unit for servicing using the instructions below Call DENTSPLY at the phone number below and obtain a service manual for a nominal fee BEFORE RETURNING THE UNIT Call DENTSPLY for an RMA Return Material Authorization number This is used to track and identify your unit Equipment received without this number may not be identifiable Equipment damaged in shipment as a result of improper packing may not be paid by the carrier DENTSPLY will not be responsible for damages resulting from improper packing Ship prepaid to DENTSPLY Ceramco RMA Number 13553 Calimesa Blvd Yucaipa CA 92399 1203 USA equipmentrepair ca dentsply com Phone 909 795 2461 Fax 909 795 5268 DECLARATION OF CONFORMITY DENSPLY CERAMCO 13553 Calimesa Blvd Yucaipa CA 92399 USA DENTSPLY Ceramco certifies that the following product Name WAXPENCIL PRO Serial Number yyww xxx Where x is a number from 0 9 Conforms with the basic requirements of the following EC guidelines Low Voltage Directive 73 23 EEC with 1 Modification 93 68 EEC EMC Directive 89 336 EEC Electromagnetic Compatibility with 1 Modification 92 31 EEC 2 Modification 93 68 EEC ROHS Directive 2002 95 EC Regulation of Hazardou
7. s Substances Lead Mercury Cadmium Hexavalent Chromium Polybrominated Biphenyls PPBs or Polybrominated Diphenyl Ethers PBDEs The regulated hazardous substances have been eliminated or controlled to the specified concentrations of 0 1 for materials listed above except for Cadmium which is specified at 0 01 WEEE Directive 2002 96 EC Waste from Electrical and Electronic Equipment reuse recycling recovery and disposal The WEEE Directive on electrical and electronic waste disposal and recycling is implemented through our EU representative listed below The following Harmonized Standards were applied EN 61010 2001 Safety IEC 61010 1 2001 Safety IEC 61010 2 010 2003 Safety EN 61326 1998 EMC not agency tested no switching devices DENTSPLY Ceramco s quality system meets these requirements ISO 13485 2003 Quality EU Rep DeguDent GmbH Rodenbacher Chaussee 4 D 63457 Hanau Germany Phone 49 6181 59 57 59 Fax 49 6181 59 59 62 Ql Pak Er zer Electronic Project Engineer Plant Manager Johh H Holbeck Date 1 31 2007 chanical Project Engineer WARRANTY WARRANTY Except with respect to those components parts and uses which are hereinafter described DENTSPLY Ceramco warrants this unit to be free from defects in material and workmanship for a period of 180 days from the date of sale DENTSPLY Ceramco s liability under this warranty is limited solely to repairing
8. t use solvents or liquid cleaners on the control panel If the unit is not operated in the manner as specified in this manual the protection provided by the unit may be impaired N CAUTION RISK OF DANGER BURN HAZARD IS PRESENT PENCIL TIPS MAY BE HOT SYMBOL TABLE mu Alternating current Courant alternatif On Supply Marche alimentation O Off Supply Arr t alimentation AN Caution Hot Surface Attention surface chaude D Protective Conductor Terminal Borne de masse ch ssis Caution Risk of Danger Attention risque de DANGER TECHNICAL DATA ELECTRICAL RATINGS Model Number Volts Frequency Watts 9995337 120V 50 60Hz 15W 9995338 230V 50 60Hz 15W DIMENSIONS Length 5 Width 2 5 Height 5 PENCIL VOLTAGE 6V ac Max SYSTEM SHIPPING WEIGHT 1 5 Kg 3 4 Lbs TEMPERATURE CONTROL RANGE 100 C to 200 C 212 F to 392 F OPERATING TEMPERATURE 5 C to 40 C 41 F to 104 F FUSE Mains 0 25 Amps 230V 5 x 20mm FEATURES Dual pencil electric wax spatula with individual controls Small foot print durable metal cabinet Cool touch pencils with pencil trays 8 assorted interchangeable tips ACCESSORIES Part Number Description 9995482 Control Box 120V 9995485 Control Box 230V 9995483 Pencil Black 9995484 Pencil White 9995344 Tip 7 3 pk 9995345 Tip 6 3 pk 9995346 Tip 8 3 pk 9995347 Tip 2 3 pk 9995348 Tip 3 3 pk 2 3 9995349 Tip 11 3 pk 99