1. 6 Press TIMER Timer On indicator light will flash Display will show remaining hours before the air conditioner will turn on 7 Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours 8 After 5 seconds Timer On indicator light will remain on Display will show the current room temperature To clear Timer delay program NOTE Air conditioner can be either on or off 1 Press TIMER once after it has been programmed Display will show remaining time 2 While the display is showing the remaining time press TIMER again Timer Off indicator light will turn on To see or change the remaining time in hours 1 Press TIMER once after it has been programmed Display will show remaining time EE Haier Domestic Air Conditioner Haier ESA08 and Functions 2 While the display is showing the remaining time press the up or down TEMP TIME button to increase or decrease the time 3 After 5 seconds the display will show the current room temperature Using the Remote Control NOTE Remote control may differ in appearance ON OFF S CH Move E SPEED ZEE EA TEMP TIME TEMP TIME Haier NOTE One CR2025 battery included powers the remote control Replace battery after 6 months of use or when the remote control starts to lose power Power Press ON OFF to turn on the air conditioner ON OFF Mode Press MODE to choose Fan Cool Energy Saver
2. Approved by Wang Xi Bo Domestic Air Conditioner
3. Press SPEED to select High Med or Low fan speed Because the fan does not circulate the room air continuously less energy is used but the room air is not circulated as often m Dehum Dries the room The air conditioner automatically selects the temperature Fan runs on Low speed only NOTE Dehum mode should not be used to cool the room MODE CC ran ENERGY Ce beEnum NOTE After 5 seconds display will show the current room temperature Fan Speed NOTE In Dehum mode the Speed button will not operate 1 Press FAN SPEED until you see the indicator light glow for the desired setting 2 Choose High Med or Low m High for maximum cooling m Med for normal cooling m Low for minimum cooling SPEED Low NOTE After 5 seconds the display will show the current room temperature Temperature m Pressthe TEMP TIME up arrow button to raise the temperature Each time you press or hold the TEMP TIME up arrow button the temperature will go up 1 F until it reaches 86 F 30 C NOTE After 5 seconds the display will show the current room temperature UE Haier Domestic Air Conditioner Haie ESA08 J PartdandFunctions A TEMP TIME m Press the TEMP TIME down arrow button to lower the temperature Each time you press or hold the TEMP TIME down arrow button the temperature will go down 1 F until it reaches 61 F 16 C NOTE After 5 seconds the display will
4. 3 3 1 e e 1 fT e c CH 1 1 E E E 2i ET EZ Ut pa pa S E E 2 a e t gt gni 3 3 E E amp 4 4 10070 As M oot T Real E E X 5 E E 2 H bo B T T 1 T T T Tx 12 wien LMS 9MS SMS A EMS TMS IMS 8A lux AON dads WANIL An HAIL dWRl 1904 DRLOSISSINE anto anyo SS 12 TID y X01 GE d AS 21 Domestic Air Conditioner Haier ircuit Diagram ESA408J Haier 0SCT A 8 Ost 1 8 OINO OOVFZ68 VS ACI 0SCT A 8 O tI 8 6NO JOVFEC68 VS ACI OSCT A 8 Ost I 8 8NO OOVFEC68 VS ACI LAM 12 08 1 ED owvrami6evscAzil 1 l d d Ir T ATI e 12209 LU S080 31 6 4 YHX gza CH i 01 I AO0S InZ v SI N ENO TE 6 022 ou m ATI ATI TH 3L eme geg TI AS ER TNI 24 LE 6080 1 S IET 0 5 E END COVAOTT de B Ae
5. Timer to turn on the air conditioner changing the previous settings 1 Turn on the air conditioner 2 Adjust the mode to Fan Cool Energy Saver or Dehum 3 For Fan Cool or Energy Saver mode adjust the fan speed to High Med or Low NOTE In Dehum mode the Speed button will not operate 4 Adjust the temperature between 61 F and 86 F 16 C and 30 C NOTE In Fan mode the temperature cannot be set 5 Wait 3 seconds before turning off the air conditioner 6 Press TIMER Timer On indicator light on the air conditioner control panel will flash Display will show remaining hours before the air conditioner will turn on 7 Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours 8 After 5 seconds Timer On indicator light on the air conditioner control panel will remain on Display will show the current room temperature To clear Timer delay program conditioner can be either on or off 1 Press TIMER once after it has been programmed Display on the air conditioner control panel will show remaining time 2 While the display is showing the remaining time press TIMER again Timer Off indicator light will turn on To see or change the remaining time in hours 1 Press TIMER once after it has been programmed Display on the air conditioner control panel will show remaining time 2 While the display is showing the remaining time press the TEMP TIME up or down arrow button
6. drill bit to drill a starter hole through the holes in the side bracket and windowsill 6 Using two 32 screws attach the side bracket to the windowsill ll NN 7 Repeat for side bracket installation on the left hand side of the air conditioner Attach Side Curtains to Window 1 Pull the left hand curtain out until it fits into the window channel 2 Use drill bit to drill a starter hole through the top hole in the side curtain and into the window sash 3 Insert one of the 732 screws through the top hole of the lefthand curtain and into the window sash 4 Repeat for the right hand curtain 5 Use a8 drill bit to drill a starter hole through the bottom hole in the side curtain and into the window frame 6 Insert one of the 732 screws through the bottom hole of the left hand curtain and into the window frame Repeat for the right hand curtain __ N Haier Domestic Air Conditioner Haier ESA408J Installation and Accessory Parts Top View Bottom View Complete Installation 1 Insert the foam seal behind the top of the lower window sash and against the glass of the upper window A Top of lower window sash B Foam seal 2 Place the window lock bracket as shown Use 8 drill bit to drill a starter hole through the hole
7. in the window lock bracket and into the upper window 3 Attach the window lock bracket to the upper window with 32 screw to secure the window in place 4 Plug into a grounded 3 prong outlet 5 Press RESET on the power supply cord See Electrical Requirements Haiet Domestic Air Conditioner Haier ESA408J Installation and Accessory Parts Parts Check that all parts are included in parts package CR2025 55 battery SC TIMER vn Haier H 1 Top channel ESA408J ESA408J L 3 B Foam seal ESA408J T 3 C Side brackets 2 3732 screws 9 D Window lock bracket G Side curtains 2 732 screws H Side curtain frames 2 1 Remote control Tools Phillips head screwdriver Flat blade screwdriver Scissors Level Socket wrench and sockets Tape measure Cordless drill and 1 8 bit Pencil Pliers Adjustable wrench 13 Haier Domestic Air Conditioner Haier ESA408J Partd and Functions 6 Partd and Functions Mode 1 Press MODE until you see the indicator light glow for the desired setting 2 Choose Fan Cool Energy Saver or Dehum wm Fan Only the fan runs Press SPEED to select High Med or Low fan speed The display shows the current room temperature m Cool Cools the room Press SPEED to select High Med or Low fan speed Press the TEMP TIME up or down arrow button to adjust the temperature Energy Saver Fan runs only when cooling is needed
8. or Dehum m MODE m se 9 gt 9 Speed Press SPEED to choose High Med or Low ES SPEED Temperature Press the TEMP TIME up arrow button to raise the temperature Each time you press or hold the TEMP TIME up arrow button the temperature will go up 1 F until it reaches 86 F 30 C TEMP TIME Press the TEMP TIME down arrow button to lower the temperature Each time you press or hold the TEMP TIME down arrow button the temperature will go down 1 F until it reaches 61 F 16 C TEMP TIME 16 Haiee 00 Domestic Air Conditioner Haie ESMO 3 J PartdandFunctions Timer To set the Timer for a 1 hour to 24 hour delay before the air conditioner is turned off the air conditioner must be On 1 Press TIMER Timer On indicator light on the air conditioner control panel will flash en TIMER NE 2 Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours 3 After 5 seconds Timer On indicator light on the air condition control panel will remain on To set Timer to turn on the air conditioner keeping previous settings 1 Turn on the air conditioner 2 Press TIMER Timer On indicator light on the air conditioner control panel will flash 3 Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours 4 After 5 seconds Timer On indicator light on the air conditioner control panel will remain on To set
9. show the current room temperature Timer Delay To set the Timer for a 1 hour to 24 hour delay until the air conditioner turns off the air conditioner must be On 1 Press TIMER Timer On indicator light will flash Display will show remaining hours before the air conditioner will turn off TIMER on 2 Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours 3 After 5 seconds Timer On indicator light will remain on Display will show the current room temperature To set the Timer to turn on the air conditioner keeping previous settings 1 Turn on the air conditioner 2 Press TIMER Timer On indicator light will flash Display will show remaining hours before the air conditioner will turn on 3 Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours 4 After 5 seconds Timer On indicator light will remain on Display will show the current room temperature To set the Timer to turn on the air conditioner changing the previous settings 1 Turn on the air conditioner Adjust the mode to Fan Cool Energy Saver or Dehum For Fan Cool or Energy Saver mode adjust the fan speed to High Med or Low em NOTE In Dehum mode the Speed button will not operate Adjust the temperature between 61 F and 86 F 16 C and 30 C NOTE In Fan mode the temperature cannot be set 5 Wait 3 seconds before turning off the air conditioner
10. with a properiy grounded outlet Do not under any circumstances cut or remove the third ground prong from the power cord Adapter Plug We strongly advise against using an adapter plug Haiet Domestic Air Conditioner ESA408J Warning and Cautions This air conditioner is designed for use in a double hung window While installing unit be sure to tilt air conditioner 5 degrees outward to have the water drip outside the house Install the unit on the north side as that is normally the shaded side This will enhance the operation of your unit The window has to be strong for installation Extra brackets and or support may be required depending on your window Brackets and supports not included in all models Measure the window before installing If the window is too big for the unit you may require professional installation Use the correct electric voltage and proper ampere for the unit to run effectively Only let a certified electrician modify your electrical outlet Use a dedicated line for the operation of your air conditioner to avoid the possibility of an electrical surge Energy Saving Guide Haier When installing your air conditioner make sure to seal all areas where there is a possibility of air leakage The airflow should not be blocked either inside by curtains drapes or furniture or outside by shrubs or bushes Do not needlessly use electrical light or other appliances that produce h
11. 20 D 21 0 Wiring DIAG e 23 Haiet Domestic Air Conditioner Haief ESA408J Illumination and introduction 1 Product Code Illumination and Series introduction 1 Model identification ESA 1 C D A Abbreviation of Energy Star B The type of refrigerant 4 RA10A C Nominal cooling capacity BTU h with the first two numbers based on one thousand unit D Design code Examples ESA408J It represents remote control window air conditioner Cooling capacity is 8000BTU h and the refrigerant is RA10A 2 Standard situation conditions No Opdralina condition Indoor air state outdoor air state DB C WB C DB C 1 Nominal cooling 26 7 19 4 35 23 9 Haiee i Domestic Air Conditioner Haief ESA408J Specification 2 Specification Item Unit ESA408J Cooling capacity BTU h 8000 Heating capacity BTU h Power supply 1PH 115V 60HZ Power input W 740 Cooling Running current A 6 7 EER BTU h W 10 8 Power input W Heating Running current A BTU h W Indoor side dB A 63 Outdoor side dB A 67 Height inches 12 7 16 Net dimensions Width inches 18 1 2 Depth inches 14 Height inches 15 deed Width inches 20 1 4 Depth inches 17 3 4 Net kg 22 Mech Gross kg 24 Type Rotary Compressor Model 39A171A Running cap For comp 35uF 250V Pressure Hi Pressure Psig 500 Low Pressure Psig 240 R
12. 22 or Refrigerant Ge R410A OZ 20 1 Type Indoor unit centrifugal Fan Outdoor unit axial Fan Speed Indoor unit r min 1500 1300 1100 Air volume CFM 195 170 145 Moisture removal Pints hr 2 5 Haier Domestic Air Conditioner Haier ESA408J Safety and Precaution 3 Safety and Precaution A Haier WARNING Following these basic precautions will reduce the risk of fire electrical shock injury or death when using your air conditioner 1 Air conditioner must be connected to proper electrical outlet with the correct electrical supply 2 Proper grounding must be ensured to reduce the risk of shock and fire DO NOT CUT OR REMOVE THE GROUNDING PRONG If you do not have a three prong electric receptacle outlet in the wall have a certified electrician install the proper receptacle The wall receptacle MUST be properly grounded 3 DO not use if power cord is frayed or damage Also avoid using if there are cracks or abrasion damage along the length plug or connector 4 DO NOT USE AN ADAPTER OR AN EXTENSION CORD 5 When installing your air conditioner in a window make sure the window is strong enough to hold the weight of the air conditioner You also want to secure and correctly install your air conditioner property to prevent it from falling Extra brackets or support may be required depen
13. Haier SERVICE MANUAL Order No AC0911S007V0 Model No ESA408J CES a B GE n mn Feature Haier Top Discharge Airflow Pattern Modern Family look Design 3 Cool Settings 3 Fan Settings Easy to install Mounting Kit Easy Access Washable Filter Digital Time amp Temperature Display 24 Hour on off Timer A WARNIN This service information is designed for experienced repair technicians only and is not designed for use by the general public It does not contain warnings or cautions to advise non technical individuals of potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death 2009 Qingdao Haier Air Conditioner General corp Ltd All right reserved Unauthorized copying and distribution is a violation of law Haier Group Haier ESA408J Table of Contents Table of Contents 1 1 Product Code Illumination and Series introduction 1 SC SREL 2 Safety and uci mec 3 Warning AUN E 4 Installation and Accessory 6 e US UNC UN 2 2 14 Abnormity SEENEN 18 System Flow eri c
14. cessary change 10 NOT connect electrical power to the unit before installation 11 DO NOT use if power cord is worn out frayed or otherwise damaged Avoid using if here are cracks or abrasion damage along the length plug or connection 12 Be carefull of exposed sharp edges of the cabinet and sharp coils fins on the back of the unit that could cut and cause serious injury Haiet Domestic Air Conditioner Haier ESA408J Installation and Accessory Parts Window Installation Window opening measurements A Width B Height MODEL Dimension 408 A inch Min 25 63 5cm A inch Max 36 91 4cm B inch Max 13 2 8 34cm Prepare Air Conditioner for Installation Install Top Channel 1 Place the top channel on the top of the air conditioner lining up the holes in the top channel with the holes in the top of the air conditioner 2 Using four 32 screws attach the top channel to the air conditioner NOTE Your model may differ from the one shown AHO A 8 32 screws B Top channel Haiet Domestic Air Conditioner Haier ESA408J Installation and Accessory Parts Install Side Curtains NOTE Attach curtains to the air conditioner before placing the air conditioner in window 1 Place the tabbed side of the side curtain in the track on the rig
15. ding on your window 6 Do not black airflow inside or outside the air conditioner with blinds drapes protective covers shrubs or bushes 7 Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury 8 Be careful when lifting the air conditioner to install or remove the unit Always use two or more people for this 9 Always unplug the air conditioner before servicing it or moving it Domestic Air Conditioner Haier ESA408J Warning and Cautions 4 Warning and Cautions WARNINGS Following the safety messages is very important T These messages can save you from being injured or killed Warning symbols alert you to be careful and means Danger Always follow instructions to be safe and reduce chances of injury or death Warning and Danger signs will precde safety messages Electrical Safety Grou nding This room air conditioner must be grounded Grounding reduces the risk of electric shock by T providing an escape wire for the electric current The power cord has a grounding wire with a grounding plug Plug it into an outlet that is properly installed and grounded WARNING Improper use of the grounding plug can result in a risk of electric shock Call a qualified electrician if you don t understand the grounding instructions or if you are not sure A if the air conditioner is properly grounded If the wall outlet is not grounded please contact an electrician to have it replaced
16. eat Keep the blinds and drapes drawn on all other windows While cooking use an exhaust fan in the kitchen to remove the excess heat Always use the correct BTU size air conditioner to cool the room to attain optimum efficiency Domestic Air Conditioner Haier ESA408J Installation and Accessory Parts 5 Installation and Accessory Parts Check the following before you install your air conditioner 1 The units is free of all obstructions inside and outside the room e g drapes curtains Furniture plants shrubs trees other structures like building garage etc The air conditioner must have a clear unobstructed airflow through the condenser to remove heat 2 The window is strong enough to hold the weight of the air conditioner Extra brackets or supports may be needed depending on your windows Brackets or Supports not provided in all models 3 The windows sill and track are strong enough to hold the weight of the air conditioner 4 The wall is strong enough to hold the unit Extra brackets or supports may be needed depending on the wall Brackets or Supports not provided in all models 5 There is adequate and proper power supply near the air conditioner As DO NOT use adapter plugs 7 DO NOT use extension cords A 8 DO NOT cut or remove the ground prong 9 DO NOT modify the plug or the electrical wall outlet in any way If plug does not fit the electrical outlet have a certified electrician do the ne
17. hem away from the keystrokes on PCB 19 Haier Domestic Air Conditioner Haier ESA408J System Flow Chart 8 System Flow Chart Indoor Outdoor heat exchanger heat exchanger Compressor Capacillary tube Cooling o Haier Domestic Air Conditioner ircuit Diagram ESA408J Haier ircuit Diagram 9 C el N3AVS A A A A A Sh A ud d 5 ab laSEV CUHEWSCST op vast saat ra oo ES L 4 490 YAWIL NO NSAIL MOT dan HOIH 1000 ALt KOR osss ML 14 oss Bai AS JNCV8 XI i 914 29110070 Se DENTEN T WOSSEWANOD JI SCH r rra TH 5H TIN OSA 9 n Kos CON 09 WOO m 3898 EET I Wee SH ACC E VF 6080 J01 617 6080 X LT GO80 NZ 26 1 F GO8O NZ TF 6080 2 LY 6080 1 617 080 311 8080 1 e LEM on Be TOS CH H WW was d a a 3 a v a a AS m 3 3 e 3 3
18. ht hand side of the air conditioner cabinet A Tabbed side of side curtain B Lock edge side of side curtain 2 Slide the side curtain down the track until the curtain is aligned with the top and bottom of the air conditioner cabinet 3 Slide the side curtain frame into the top channel on the top of the air conditioner and the track on the bottom of the air conditioner DomesticAir Conditioner Haier ESA408J Installation and Accessory Parts 4 Slide the side curtain frame as close to the air conditioner as necessary to lock the side curtain to the frame 5 Repeat above steps for the left hand side curtain and frame Prepare Window for Installation 1 Measure the width of the window opening 2 Mark the center line on the inside windowsill A Width of window opening B Center
19. line Position Air Conditioner NOTES m Handle the air conditioner gently m Be sure your air conditioner does not fall out of the opening during installation or removal m The place where the power cord exits the air conditioner be no more than 4 ft 122 cm from a grounded outlet m Do not block the louvers in the front panel m Do not block the louvers on the outside of the air conditioner 1 Center the air conditioner in the window Lower the window sash behind the top channel to hold the cabinet in place NOTE Your model may differ from the one shown Haier Domestic Air Conditioner Haier ESA408J Installation and Accessory Parts JE A Side curtain against window channel B Window sash behind top channel C Bottom channel in behind windowsill 2 Loosen the screw on the right hand side of the air conditioner cabinet near the bottom 4 SS 2 z P 3 Slide the side bracket over the screw 4 Tighten the screw The side bracket should be resting on the windowsill E _ ee Haier Domestic Air Conditioner Haier ESA408J Installation and Accessory Parts 5 Use 8
20. tan AcHX edcH ASCInOO01 anto S anto 91 In0LF ES oa P ta ZootNI P va lasnd T L E Ei 12 CO va 0 1 8 0 1 8 IND Dl ZINO DE 9 Log T OSEAPIS ASLTANI O ome mE 22 Domestic Air Conditioner Haier Haier ESA408J Wiring diagram 10 Wiring diagram WIRING DIAGRAM Haier COMPRESSOR FAN M 5 TRANSFORMER MOTOR p VR M GR HEAT 2 PROTECTOR un BR PR CAPACITOR CAPACITOR B BUR R NLMH CN E 116 5 Lj tr COMPRESSOR 2 CN2 O J Lj a pa Ge 2 B NO RIBBED atio W RIBBED GR GRAY SR ORAN POWER SUPPLY BL BLUE R RED B BLACK W WHITE Y G YELLOW GREEN NOTE THE DOTTED PART MAY NOT BE USED Domestic Air Conditioner Haier ESA408J The end Sincere Forever Haier Group Haier Industrial Park No 1 Haier Road 266101 Qingdao China_ E mail hractech haier com Tel 86 532 87636960 Http www haier com Haier Edited by Guan Li li Hao Signed by Yao Hong Fang
21. to increase or decrease the time 3 After 5 seconds the display on the air conditioner control panel will show the current room temperature EE EE Haier Domestic Air Conditioner Haief ESA408J Abnormity Diagnose 7 Abnormity Diagnose 1 Sensor Diagnose 2 seconds after the sensors open circuit or short circuit the unit will turn off automatically and the LED wil show EO until the sensors resume Firstly check whether Terminal CN2 on Pull out the terminals on the indoor NO the indoor mainboard contact well or mainboard and reinsert them not YES Pull the sensor out of the mainboard 1 Measure the value of resistance between its two jumpers 2 Measure the temperature at the YES Replace with new sensor room temperature sensing head Check the specifications of the sensor to decide whether the sensor is damaged or not YES The Indoor PCB is broken Replace with new indoor PCB o B Haier Domestic Air Conditioner Haier ESA408J Abnormity Diagnose 2 Keystroke circuit error diagnose When power on for the first time the PCB will check the keystroke circuit if the sampling value is different with the theory value the LED will show whice means failed keystroke circuit The keyboard is locker and so invalid but the remote control is working normally Check whether the keystroke can t PCB is broken replace a new PCB get up with pressure Repair the keystrokes on electrical box to keep t