Home

5965-4792E

image

Contents

1. 100 M Frequency Hz Typical permittivity er Measurement accuracy thickness 1 mm tan Error Ea 10M 100 M Frequency Hz Typical loss tangent tan 6 Measurement accuracy thickness 1 mm AMAA NG NG TANGA ES log E4991B with 16453A Description The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991B It employs the parallel plate method which sandwiches the material between two electrodes to form a capacitor E4991B measures the capacitance created from the fixture and option E4991B 002 firmware calculates the relative complex permittivity Adjustment to insure parallel electrodes is required when using the 16451B This adjustment is not required with 16453A because the fixture has a flexible electrode that adjusts automatically to the material surface Applicable instruments E4991B with Opt E4991B 002 Frequency 1 MHz to 1 GHz Maximum voltage 42 V peak max AC DC Operating temperature 55 to 200 C When Option E4991B 007 temperature characteristic test kit is used with E4991B the operating temperature range is between 55 C and 150 C Material size Furnished accessories Description P N Qty Fixture holder 16453 01213 i Load
2. 23 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Material continued 16451B Dielectric test fixture continued Applicable instruments E4980A AL E4981A E4990A Frequency DC to 30 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C Material size Guarded electrode Cf Electrode A fa 0 2 56 p Test material Unguarded electrode Electrode A Electrode B t 40 to 56 Note signifies diameter Dimensions are in millimeters Electrodes for contacting electrode method Rigid Metal Electrode Material size for electrode A Equipped with Electrodes A and B for flat and smooth materials GO EZ Jj g5 0 13 Test material sto 10 to 56 Note signifies diameter Dimensions are in millimeters Material size for electrode B Electrode type Diameter of MUT Thickness of MUT Diameter of electrode Max frequency A 40mm 56mm t lt 10 mm 38 mm 30 MHz B 10 mm 56 mm t lt 10 mm 5mm 30 MHz Guarded electrode Guarded thin film electrode Guard electrod Note signifies diameter Dimensions are in millimeters Unguarded thin film electrode Unguarded electrod Electrode C Electrode D Electrodes for contacting electrode method Thin Film Material size for electrode C Electrode Equipped with Electrodes C and D for rough or extremely thin materials ae 28 Test material T
3. 16196A Parallel electrode SMD test fixture ou eee on 16196B Parallel electrode SMD test fixture ou eee 37 16196C Parallel electrode SMD test fixture woe 39 16196D Parallel electrode SMD test fixture ee 41 16197A Bottom electrode SMD test fixture 43 16198A Bottom electrode SMD test fixture ou 46 DC Bias ACCESSOMIGS cecccccccccccceesseeseeceeseeeennreeeceeeesenntaveeeeeeeeentanees 48 16200B external DC bias adapter orrrnrnonnnnnonnnrororrrrrrnrrnnnnnnr 48 EEE SE 49 16453A Delectric material test fIXxture rmmrrrrrrrrrrrerrvvrrrrrvnrn 49 16454A magnetic material test fixture rrrrrrrrornnrnrrrrrrrvvvnnn 50 Other ACcCessorleS mmmmmmmmmmmmmmmrrrrrrrrrr 52 16190B Performance test kit oo eee eeecccaeeeccueeecueeecutesaeeeeaeeeeeaeess 52 16380A Standard capacitor Selsins aei ikainiai Fe 163800 Standard capacitor SeLunuuassammeimim mreemmsjesivjin 54 42030A Four Terminal pair standard resistor Set rrrrrrrrrrrrrrrrrrnnn 65 FEO IEA OSH terminati EEE 56 42091A Short EINA LON xasasssacccsaccctancensacenecctnavtteanasagaasossansnzpeo decease 56 0 2 EEE A A AEE 57 Keysight Web Resources cccescsesestesssssccsecessseterscaessneraresarssarsaaesntens 60 Introduction When a device under test DUT is measured a test fixture must be used to connect the instrument to the DUT A test fixture Is an interface specifically designed to connect the instrument and the contact tips of t
4. 315 g Additional error For detailed information refer to the measurement instrument s specifications 16048D Test leads Terminal connector 4 Terminal Pair BNC Cable length approx 1 89 m from connector to cable tip Cable tip BNC male Weight approx 460 g Additional error For detailed information refer to the measurement instrument s specifications Description The test leads extend the measurement port with a 4 Terminal Pair configuration It is provided with a BNC female connector board to allow the attachment of user fabricated test fixtures Applicable instruments E4980A AL E4981A Frequency DC to 30 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C Furnished accessories Description P N Qty Terminal board with BNC f x4 16032 60071 1 Operating manual 16089 90001 i Compensation and measurement Cable length compensation is recommended before measurement Set the instrument s cable length compensation function to I m Description The test leads extend the measurement port with a 4 Terminal Pair configuration It is provided with a BNC female connector board to allow the attach ment of user fabricated test fixtures Applicable instruments E4980A AL E4981A Frequency DC to 30 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C Furnished accessories Description P N Qty Terminal board with BNC f x4 16032 60071 Operating man
5. Compensation and measurement Open and short compensations are recommended before measurement For open compensation do not connect the Kelvin clips to any thing Short compensation is performed by holding a shorting plate with the Kelvin clips After performing open and short compensations the DUT is held with the Kelvin clips 16089B Medium Kelvin clip leads Description This test fixture makes it possible to measure odd shaped components that cannot be measured with conventional fixtures It is equipped with two insulated Kelvin clips Applicable instruments E4980A AL E4981A E4990A Frequency 5 Hz to 100 kHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C DUT size See figure below Terminal connector 4 Terminal Pair BNC DUT connection 4 Terminal Cable length approx 0 94 m from connector to clip s tip Weight approx 300 g Additional error The additional error is neg ligible when compared to the instrument s Furnished accessories accuracy Description P N Qty Operating and service manual 16089 90020 i Compensation and measurement Open and short compensations are recommended before measurement For open compensation do not connect the Kelvin clips to anything Short compensation is performed by connecting the Kelvin clips together After performing open and short compensations the DUT is held with the Kelvin clips A 16 Keysight Accessories Catalog for Impedance M
6. 16048E Four meter test leads BNC E4980A AL 16048G One meter test leads BNC 120 MHz E4990A 16048H Two meter test leads BNC 120 MHz E4990A 16065A Ext Voltage bias with safety cover E4980A AL E4981A E4990A lt 200 vdo 16065C External bias adapter lt 40 vdc E4981A E4980AL 16089A B C Kelvin clip leads E4980A AL E4981A E4990A 16092A RF spring clip axial radial and SMD E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 w Opt 005 16201A 16190B Performance test kit E4982A E4990A 120 E4991B 16192A Parallel electrode SMD test fixture E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 w Opt 005 16201A 16194A High temperature component test fixture refer to 16192A 16196A B C D Parallel electrode SMD test fixture refer to 16192A 16197A Bottom electrode SMD test fixture refer to 16192A 16198A Bottom electrode SMD test fixture E4982A E4991B E5061B 3L3 3L4 3L5 w Opt 005 16201A 16200B External DC bias adapter E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 w Opt 005 16201A 16334A SMD chip tweezers E4980A AL E4981A E4990A 16380A C Standards set E4980A AL E4981A E4990A 16380C C Standards set E4980A AL E4981A E4990A 16451B Dielectric material test fixture E4980A AL E4981A E4990A 16452A Liquid test fixture E4980A AL E4990A 16453A Dielectric material test fixture E4991B w Option 002 16454A Magnetic material test fixture E4990A 42942A E4991B w Option 002 42030A Four Terminal pair
7. Guide PCA 0402 100 micrometer 16198AU 202 0201 Short bar 5 piece set 16198AU 110 0402 Short bar 5 piece set 16198AU 210 Weight 50 g 16198AU 520 Weight 100 g 16198AU 521 Weight 200 g 16198AU 522 Carrying case Torque driver 16198AU 530 16198AU 531 Pusher unit 16198AU 540 DUT cover ass y 16198AU 544 Connector APC3 5 16198AU 545 48 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm DC Bias Accessories 16200B external DC bias adapter Terminal connector 7 mm DC BIAS input connector BNC f Voltage monitor connector BNC f Dimensions approx 170 W x 70 H x 130 D mm Weight approx 900 g Se 0000 OE 60 0000 ae GY ea08 D Connection example Description This test fixture is designed to measure a DUT with DC bias By connecting an external DC current source to the 16200B it can supply a bias current across the DUT of up to 5 Adc through a 7 mm port Applicable instruments E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Option E4990A 120 is required Frequency I MHz to I GHz DC bias Up to 5A 40 V Input Operating temperature 0 to 55 C Applicable fixtures 16192A 16194A 16196A B C D 16197A 16092A Furnished accessories Description P N Qty Operation and service manual 13200 90011 i 16200B 001 Shorting device set Size P N Qty 0 6 x 0 3 x 0 3 mm 16197 29001 2 1 x 0 5 x 0 5 mm 16191 29005
8. Impedance probe Printed circuit board In circult measurement 21 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair DC Bias Accessories 16065A 200 Vdc external voltage bias fixture Description This test fixture makes it possible to measure a DUT with up to 200 V DC bias The same modules of 16047A can be used to allow measurements of axial radial lead components Applicable instruments E4980A AL E4981A E4990A Frequency 50 Hz to 2 MHz Maximum DC bias 200 V DC max 15 V peak AC max Blocking capacitor of 5 6 uF is connected in with the Hc terminal Operating temperature 0 to 55 C er DUT Size See the 16047A figure with module sizes Furnished accessories Ne good Terminal connector 4 Terminal Pair BNC DUT connection 4 Terminal Description P N Qty External bias input connector High Voltage BNC f Module for axial lead 16061 70022 Dimensions approx 180 W x 120 H x 200 D mm Module for radial lead mounting on fixture 16061 70021 i Cable length approx 40 cm Ge EE DOTEN Weight approx 1500 g odule for short radial lea 65 Shorting bar 16047 00640 Operating and service manual 16065 90011 i Compensation and measurement Open short and load compensations are recom gt EG mended before measurement Short compensation is performed by shorting the contacts of the test fixture with a shorting plate as described for the 16047A
9. short and load compensations in combination with the electrical length compensation the DUT is inserted into the test fixture The following figures show how measurement is performed Electrode O Press anser IO a Adjust the ground plate and move the arm c Leaded device d Leaded device DUT measurement SHORT LOAD compensation Placing the device 34 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196A Parallel electrode SMD test fixture Terminal connector 7 mm DUT connection 2 Terminal Electrical length 26 2 mm Dimensions approx 140 W x 48 H x 78 D mm Weight approx 250 g Additional error Type of error Proportional error Open repeatability Short repeatability f frequency GHz E4982A with 16196A Impedance 1 0 x f 5 40 xf US 30 125 x f mQ Fixture cap eo DUT insertion hole Insulator Fixture overview QT lens Description This test fixture is designed for impedance evaluations of parallel electrode SMDs It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements The applicable SMD size code is 0603 inch 1608 mm Applicable instrument E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Option E4990A 120 is required Frequency DC to 3 GHz Maximum voltage 42 V peak max
10. 17 Ni 29 Insulator Alumina AL 0 O ring Viton Fluro rubber Test fixture overview Low electrode spacer 0 OS Cs Thickness 1 3 mm Shorting plate ee High electrode Cross section Short compensation E4980A 4285A Drain liquid must be capped Method of connection Compensation and measurement Short compensation is recommended in combination with the cable length compensation before measurement First set the instrument s cable length compensation function to 1 m Then short compensation is performed by using the furnished shorting plate Open compensation is not performed but its values are used in the dielectric constant equation as shown below Ar w CoRp a Correction coefficient Relative dielectric constant Cp Liquid capacitance measurement data Co Air capacitance measurement data or open compensation data Rp Equivalent parallel resistance measurement data w Angular frequency w 2mf The following figures below show how compensation and measurement is performed 2 To prevent bubbles from entering pour the liquid into the inlet of the fixture until it reaches the liquid level marked by the dotted line The liquid level where the electrode is completely full with liquid wit Ly x 1 Fasten the lid Pouring the liquid into the fixture Note The 16452A is not capable of measuring salt or ionic solutions or other liquids with bulk conductivity due to the el
11. DUT connection 2 Terminal Dimensions approx H 0 3 1 6mm 120 W x 50 H x 70 D mm Weight approx 200 g Additional error Furnished accessories Maximum voltage 42 V peak max AC DC Description This test fixture is designed for impedance evaluations of SMD The minimum SMD size that this fixture is adapted to evaluate is 0 6 L x 0 3 W mm Applicable instruments E4980A AL E4981A E4990A E5061B 3L3 3L4 3L5 Description P N Qty Type of error Impedance Case for 100 Q SMD resistance 1540 0692 1 Proportionalerror 0 5x 10M 1000 chip resistor 0699 2488 10 Open repeatability 5 500x 10 nS Operating manual 16034 90011 1 Short repeatablity 10 13 x f 10 mQ fMJ 2 Compensation and measurement Open and short compensations are recommended before measurement When measuring above 3 MHz load compensation is also performed LOW DC BIAS Short compensation Device holder top view DUT measurement Dimensions recommended Open compensation is performed by separating the high and the low electrodes from each other The separation size should be equivalent to the DUT s width Short compensation is performed placing the high and low electrodes in contact together Load compensation is performed by using the furnished 100 Q SMD chip resistor After performing open short and load compensations the DUT is inserted into the test fixture The following figures show how compensat
12. Description P N Qty Shorting plate 16092 08010 1 E O ring for liquid outlet 0905 1277 D Spacer 1 3 mm thickness 16452 00601 1 F Spacer 1 5 mm thickness 16452 00602 1 F Spacer 2 0 mm thickness 16452 00603 1 F Spacer 3 0 mm thickness 16452 00604 1 F EE Lid of liquid outlet 16452 24002 1 G Pe Ke am eK pel SMA BNC adapter 1250 1200 4 H Frequency Hz Waterproof cap for BNC connector 1252 5821 4 Carrying case 16452 60111 1 Error C Measurement Error of Instrument Operation and service manual 16452 90020 1 7 ai and service manual 16492 90020 Angle iron of stand body for fixture stand 16452 01201 2 Screw of stand body or fixture stand 0515 0914 4 G Screw for fixture stand 0515 0914 4 Stand foot 16452 00611 Electrode high and low NA 2 A B Requires the following interface cables to connect to a measurement instrument Select accordingly to the required temperature conditions Temperature Model or P N Cable length approx 0 to 55 C 16048A 0 94 m E 20 to 150 C 16048G for E4990A only 1m LCR meter with 16452A 20 to 150 C 16048H for E4990A only 2m Four BNC m to BNC m adapters P N 1250 0216 are needed to connect the 16048G H and 16452A 27 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Material continued 16452A Liquid dielectric test fixture continued Fixture materials Electrode Ni plated Cobal Fe 54 Co
13. Load compensation is performed by inserting a known standard device After performing High Voltage BNC f connector for external bias input open short and load compensations the DUT is connected to the test fixture BNC f connector for voltage monitor output Instrument a gojogaa 0 000 aAA 0000 En External DC bias source 16065A LCR meter with 16065A 16065C 40 Vdc external voltage bias adapter Description This adapter is designed to operate specifically with the E4981A and the E4980AL By connecting an external DC voltage source to this adapter a bias voltage of up to 40 V can be supplied to a DUT The DUT can be inserted by connecting any direct attachment 4 Terminal Pair test fixture to the adapter Applicable instruments E4981A and E4980AL Frequency 100 Hz to I MHz Maximum DC bias 42 V peak max AC DC Terminal connector 4 Terminal Pair BNC Blocking Capacitor of 100 UF is connected in series with the Hc terminal External bias input connector BNC f Operating temperature 0 to 55 C Dimensions approx 160 W x 50 H x 150 D mm Applicable fixtures 16034E G H 16047A E 16048A D 16089A B C Cable length approx 210 mm Furnished accessories Weight approx 450 FMS Description P N Qty Instrument Operating and service manual 16065 90020 i 2206 Compensation and measurement Open and short compensations are recom H mended before measurement Short compensation is performed
14. available at www keysight com find contactus Americas Canada Brazil Mexico United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries Europe amp Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 877 894 4414 55 11 3551 7910 001 800 254 2440 800 829 4444 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 421 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 65 6375 8100 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt 1 DE Opt 2 FR Opt 3 IT 0800 0260637 For other unlisted countries www keysight com find contactus BP 6 20 17 R tified IS anagement System www keysight com go quality Keysight Technologies Inc DEKRA Certified ISO 9001 2015 Quality Management System This information is subject to change without notice Keysight Technologies 2001 2017 Published in USA December 1 2017 5965 4792E www keysight com
15. configuration It is provided with a BNC male connector board to allow the attachment of user fabricated test fixtures Applicable instrument E4990A Frequency DC to 120 MHz Maximum voltage 42 V peak max AC DC Operating temperature 20 to 150 C Furnished accessories Description P N Qty Mounting plate NA Terminal connector 4 Terminal pair BNC Operating and service manual 16048 90050 Cable length approx 1 m Options Cable tip BNC female 16048G 001 Add BNC Bracket P N 16048 60003 Weight approx 460 g Additional error For detailed information refer to the operation manual or the specifications of E4990A Here the BNC Bracket refers to the terminal board with four BNC m connectors Compensation and measurement Adapter setup is recommended before measurement In the adapter setup menu select 4TP 1M Then use the 100 Q resistor furnished with the E4990A to perform phase compensation and load data measurement 1 Instrument side connection block 2 Connection block securing screw 3 Ground lead 4 DUT side connection block 5 Mounting plate Test fixture overview 16048H Test leads Description The test leads extend the measurement port with a 4 Terminal Pair configuration It is provided with a BNC male connector board to allow the attachment of user fabricated test fixtures Applicable instrument E4990A Frequency DC to 120 MHz Maximum voltage 42 V peak max AC DC Opera
16. plate After performing open and short compensations the DUT is connected to the test fixture The following figures show how compensation and measurement are performed Shorting bar terminal Guard terminal 1 Electrode 3 Fixture fastening screws 3 Fixture fastening screws 2 Electrode securing screws Test fixture overview Connecting a shorting plate Measuring 3 Terminal device 11 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair SMD 16034E Test fixture 16032 une oono a Terminal connector 4 Terminal Pair BNC DUT connection 2 Terminal Dimensions approx 128 W x 60 H x 71 D mm Weight approx 270 g Additional error Type of error Impedance Proportionalerror 1 5 x f 10 f MHz Put the DUT where it is touched by the end of the low electrode 1 Loosen the Knob 2 Push the end of the high electrode until it touches the DUT 3 Tighten the Knob 4 Pull the lever of the low electrode and remove the Description This test fixture is designed for impedance evaluations of SMD The minimum SMD size that this fixture is adapted to evaluate is 1 6 L x 0 8 W mm Applicable instruments E4980A AL E4981A E4990A E5061B 3L3 3L4 3L5 with Opt 005 Frequency DC to 40 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 C to 55 C DUT size See figure below L 0 1 8 0 mm W 0 5 10mm Vy
17. standard resistor set E4980A AL E4981A E4990A 42090A Open termination E4980A AL E4981A E4990A 42091A Short termination E4980A AL E4981A E4990A 42941A Impedance probe kit E4990A 42942A Four Terminal pair to 7 mm E4990A Option E4990A 120 is required Applicable measurement instrument s Page s 11 Z 15 16 29 52 30 31 32 33 34 42 43 45 46 47 48 99 04 22 25 26 2 49 50 51 09 56 56 20 Q 58 Keysight Accessories Catalog for Impedance Measurements Catalog Index continued Test fixture selection by SMD size Applicable SMD size code in mm EIA code in inch BEE SSESSSSESRR O A sty O OO N N CO CO N Maximum 222929222 Z xZ Q Minimum Maximum NG NSG NG SS SSS SSE SS NS NS NSG S Classi Testfixture Model Electrode usable EEE SN LxWxH fication type number type frequency S S 8 2 fH HS F FB mm mm SMD General 16034E Parallel 40 GHz eo 01 X0 5X0 5 8x 10X10 SMD General 16034G Parallel 120 MHz n 8 01x0 3x0 3 5x1 6x1 6 ATP SMD General 16034H Parallel 120 MHz ms n O1X06x06 5x15x3 SMD 16334A Parallel 15 MHz nm SeeNote L lt 10 Tweezers SMD Lead 16092A Parallel 500 MHz See Note 6 L lt 18 SMD General 16192A Parallel 2 GHZ n gt L20 SMD Lead 16194A Bottom 2 GHz n L gt 2 L lt 15 SMD Coaxial 16196A Parallel 3 GHz a 1608 size only RF SMD Coaxial 16196B Parallel 3 GHz x 1005 size onl
18. the DUT is complete remove the DUT from the fixture by using the furnished push ring Refer to the 16196A figures to see how compensation and measure ment is performed 39 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196C Parallel electrode SMD test fixture Terminal connector 7 mm DUT connection 2 Terminal Electrical length 27 1 mm Dimensions approx 140 W x 48 H x 78 D mm Weight approx 250 g Additional error Type of error Impedance Proportional error 1 0 x f Open repeatability 5 40 xf US Short repeatability 30 125 x f mQ f frequency GHz Description This test fixture is designed for impedance evaluations of parallel electrode SMDs It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements The applicable SMD size code is 0201 inch O603 mm Applicable instrument E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Option E4990A 120 is required Frequency DC to 3 GHz Maximum voltage 42 V peak max AC DC Operating temperature 55 to 85 C DUT size The applicable SMD size is 0201 inch O603 mm For details see the figure below DUT insertion hole diameter D DUT 0 6 0 03 mm Electrode Insulator assembly The 16196C is furnished with one insulator assembly See the table below for the dimensions of the insulator a
19. 10 Lower electrode 5 piece set for 16196C Compensation and measurement Open and short compensations are recommended in combination with the electrical length compensation before measurement The fixture s electrical length must be entered into the electrical length compensation function of the measurement instrument first Next open compensation is performed by placing the furnished open plate on top of the insulator assembly Short compensation is per formed by placing the furnished shorting plate on top of the insulator assembly After performing open and short compensations in combination with the electrical length compensation the DUT is inserted into the test fixture Once the measurement of the DUT is complete remove the DUT from the fixture by using the furnished push ring Refer to the 16196A figures to see how compensation and measurement is performed 41 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196D Parallel electrode SMD test fixture Terminal connector 7 mm DUt connection 2 Terminal Electrical length 27 3 mm Dimensions approx 140 W x 48 H x 78 D mm Weight approx 250 g Additional error Type of error Proportional error Open repeatability short repeatability f frequency GHz Impedance 1 077 P 5 40 xf US 30 125 x f mQ Description This test fixture is designed for impedance evaluations of parall
20. 16383A 1000 pF 16384A These Capacitors are primarily used for performance tests of Keysight s 4 Terminal Pair LCR meters and impedance analyzers Refer to the instrument s operation service manual 16383A 16384A 100 pF 1000 pF Qty aa 4 3 N 93 93 Operating note 16380 90011 54 Keysight Accessories Catalog for Impedance Measurements Catalog Other Accessories continued 16380C Standard capacitor set Terminal connector 4 Terminal Pair BNC Dimensions approx 142 W x 88 H x 112 D mm capacitors Weight approx 7 0 kg including case and 3 capacitors Description The 16380C is a standard capacitor set consisting of three precision capacitors 0 01 uF 16385A 0 1 uF 16386A and 1 uF 16387A These capacitors are primarily used for performance tests of Keysight s 4 Terminal Pair LCR meters and impedance analyzers Refer to the instrument s operation service manual for the method of using these standards Applicable instrument E4980A AL E4981A E4990A 16385A 16386A 16387A Capacitance 0 01 UF 0 1 UF 1 UF Nominal accuracy 0 10 0 10 0 10 Calibration stability lt 50 ppm year Dissipation factor lt 0 0004 lt 0 0005 lt 0 0007 Furnished accessories Description P N 16385A 0 01 uF N A 16386A 0 1 uF N A 16387A 1 uF N A BNC f f Adapters 1250 0080 Calibration report N A Carrying case 16380 85104 Operating note 16380 90221 Option 16380C 001 Add 10 uF standar
21. 16453 60021 Tweezers 8710 2081 i Carrying case 16453 60011 1 Operation and service manual 16453 90010 i Compensation and measurement Open short and load compensations are recommended before measurement Open compensation is performed by separating the high and the low electrodes from each other Short compensation is performed by connecting the high and low electrodes together Load compen sation is performed by using the furnished load material After performing open short and load compensations the material under test is inserted into the test fixture 50 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm Material continued 16454A magnetic material test fixture Description The 16454A is designed for accurate permeability measurements of toroidal shaped magnetic materials Since the construction of this fixture the need of 7 with no magnetic flux leakage winding a wire around the toroid is unnecessary The following figure shows the creates one turn around the toroid ility is calculated from it ex permeabi turn mechanism and how comp one Relative permeability Zm Measured impedance with toroidal core Terminal connector 7 mm Dimensions approx Large test fixture Small test fixture Weight approx Zsm Measured impedance with toroidal core Ho E4991A 4291B 4294A Permeability of free space Under Test Materi
22. 2 1 6 x 0 8 x 0 8 mm 16191 29006 2 2 0 x 1 2 x 0 8 mm 16191 29007 Z 3 2 x 1 6 x 0 8 mm 16191 29008 2 16200B 001 Load device set Size P N Qty 0 6 x 0 3 x 0 3 mm 0699 6926 d 1 x 0 5 x 0 5 mm 5182 0433 D 1 6 x 0 8 x 0 8 mm 5182 0434 5 2 0 x 1 2 x 0 8 mm 5182 0435 5 3 2 x 1 6 x 0 8 mm 5182 0436 D Options 16200B 001 Add Working std set Compensation and measurement When using the 4291B follow these instructions Perform open short load and low loss calibration at the 7 mm test port of the 4291B Connect the 16200B to the 7 mm test port and connect the test fixture onto the 16200B Open short and load compensations are recommended before measurement Use the short bars and 51 Q SMD resistors furnished with 16200B 001 to perform short and load compensation respectively When using other instruments follow these instructions Connect the 16200B to the 7 mm test port of the measurement instrument Perform open short load and low loss calibration at the 7 mm test port of the 16200B Then connect the test fixture onto the 16200B and perform open short and electrical length compensations in the usual manner 49 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm Material 16453A Delectric material test fixture Terminal connector 7 mm Dimensions approx 130 H x 50 W x 60 D mm Weight approx 600 g Measurement accuracy including the E4991B
23. 2942A Terminal adapter Applicable instrument E4990A SEG Frequency 20 Hz to 120 MHz Dm Maximum voltage 42 V peak max AC DC a Operating temperature Oto 40 C Furnished accessories Description P N Qty Carrying case 42942 60011 i Operation and service manual 42942 90020 i i Option E4990A 120 i ired Dimensions approx pugn is require 190 W x 55 H x 140 D mm Options Weight approx 800 g 42942A 700 Add 7 mm open short load set Description P N Qty Open termination 04191 85302 i Short termination 04191 85300 Load termination 04291 60043 i 06 Keysight Accessories Catalog for Impedance Measurements Catalog Accessories Catalog Applicable frequency ranges Frequency range 1 G Hz 2 G Hz 16047A 16047E 16034E 16034G H 16334A 16089A B C 16048A D 16048E 16048G H 42941A 16065A 16065C 16451B 16452A 16092A 16192A 16194A 16196A B C D 16197A 16198A 16200B 16453A 16454A 07 Keysight Accessories Catalog for Impedance Measurements Catalog Accessories Catalog Accessories organization This document is organized by measurement frequency and DUT to enable quick selection of an appropriate test fixture for a particular measurement application The following tables show the various categories in each primary group Up to 120 MHz Terminal configuration 4 Terminal pair Lead components SMD components Other components Port Cable extension D
24. 4 mm 18mm Dimensions approx 150 W x 70 H x 80 D mm lt gt gt 0 65 mm Weight approx 180 g Additional error See figure below Model 16092A Residual parameters 16092A R Furnished accessories Residual R mQ Stray conductance uS Description P N Qty 0 Shorting plate 16092 08010 Operating note 16092 90010 Compensation and measurement Open and short compensations are recommended in combination with the electrical length compensation before measurement The fixture s electrical length must be entered into the electrical length compensation function of the measurement instrument first When using the SMD module open compensation is performed by separating the high and the low electrodes from each other The separation should be equivalent in size to the DUT s width Short compensation is performed by usinf the furnished shorting plate When using the lead component module open compensation is performed by not having the module electrodes be connected to anything Short compensation is performed by using the furnished shorting plate After performing open and short compensations in combination with the electrical length compensation the DUT is inserted into the test fixture Inserting the leaded component 30 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD 16192A Parallel electrode SMD test fixture Terminal connector 7 mm DUT c
25. 4A magnetic material test fixture continued Furnished accessories EE Description P N Qty CE E EL ake Fixture holder 16454 00601 1 Tweezers 8710 2081 1 Screw hex recess 0515 1050 1 Holder A 16454 25002 1 Holder B 16454 25001 1 Holder C Without hole 16454 25004 1 E4991B with 16454A Holder D With hole 16454 25003 1 Holder case 1540 0622 1 Hex key for replacing fixtures 8710 1181 1 Carrying case 16454 60101 i Operation and service manual 16454 90020 Compensation and measurement Short compensation is required before measure ment Short compensation is performed by only inserting the MUT holder into the test fixture After performing short compensation the MUT is inserted into the fixture as shown below Short compensation Remove the cap of the fixture Place a MUT holder only in the fixture Replace the cap by screwing tightly Placing the MUT on the test fixture as follows Remove the cap of the fixture Place a MUT onto the MUT holder and insert it Replace the cap by screwing tightly into the fixture 52 Keysight Accessories Catalog for Impedance Measurements Catalog Other Accessories 16190B Performance test kit Terminal connector 7 mm Dimensions approx 350 W x 100 H x 270 D mm Weight approx 2 0 kg Description The 16190B is a performance test kit designed to verify the impedance measurement accuracy of LCR meters or impedance analyzers that ha
26. 5 16089A Large Kelvin clip leads verernnnnnrrraanrrrrernvvvnrnnnnnnrnnnnnn 15 16089B Medium Kelvin clip leads rrrrrrrrrrrrrrrrnrnonoroosnnnnnnnnnnn 15 GL EO oe EEE 16 Port Cable Extension mmrrrrvrrorerovvrrsrvrrnrerrnrersnrernrenrnrerrnrensrnnnnrnnn 17 16048A Test leads x ccrcocssacnscnasiananswawensradernseretaarcaehanehaaereewuncenwens 17 16048D Test leads SEE EE 17 16048E Test leads rrrrrrrrrrrrrrrrrnnrnnrnrrrrrrrrrrrrrnnnnnnnnnsssnsnnnnnnnnnn 18 TOA GE EE 19 TAT Test CAS JER 19 15 0 sects E A ge casero eee cee ee ae E 20 42941A Impedance probe Kit rrrrrnnnnnonrrrrrrrrnnnnnnnnnnnnnrrrnnnnnnnn 20 DC Bias Accessories c ccccccccccenscetsecscesseeceeeesseeeecssecseecesecseeensees 21 16065A 200 Vdc external voltage bias fixture occ 21 160650 40 Vdc external voltage bias adapter ee 21 CLC US EEE RE 7 1645 1B Dielectric test fixtU Civ isincnsicnaniocecanccantacnasecnasanassudothonhatt Za 16452A Liquid dielectric test fiXture mmerrrrrrrrrrrrrnnnnnnnnnrrrrnn 26 ii Keysight Accessories Catalog for Impedance Measurements Catalog Table of Contents continued i EE 28 Lead Components rmrrvornronnnvrrnronnronnronsvorsronsnnnnnrensvennvonsnnnnnnnrnnen 29 16092A Spring clip TIXTULE cc cccccccccceeeeeeeeeeeseeeeeeeeeeesseeees 29 Essens S E E EAEE 30 16192A Parallel electrode SMD test fixture wo ee 30 16194A High temperature component test fixture 0088 32
27. 5 to 85 C DUT size The applicable SMD size is 0402 inch 1005 mm For details see the figure below DUT insertion hole diameter DUT 1 0 0 1 mm 0 5 0 1mm i Electrode Insulator assembly The 16196B is furnished with three different insulator assemblies since any gaps between the DUT and the cylindrical insulator will result in improper positioning and subsequent measurement errors Select an insulator assembly that reduces the gap the most See the table below for dimensions of the insulator assemblies Hole diameter of insulator assembly mm SMD case size examples Length width height mm 161965 o 0 85 1 0x0 5x 0 5 o 0 75 10505035 amp 0 68 100500 Furnished accessories Description P N Qty Operation and service manual 16196 90040 i Insulator assembly 0 85 mm 16196 60212 Insulator assembly 0 75 mm 16196 60213 i Insulator assembly 0 68 mm 16196 60214 i Open plate 16196 29002 i Short plate 16196 29027 Push ring 16196 24004 Magnifying lens 16193 60002 1 Tweezers 8710 2081 1 Wrench 8710 0909 i Cleaning rod 5182 7586 Carrying case 16196 60250 1 Opt 16196B 710 only 38 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196B Parallel electrode SMD test fixture continued Options 16196B 710 Add the magnifying lens and tweezers To maintain adequate measurement performance keep the electrodes and the shor
28. 90A Open termination LALLA Description The 42090A is an open termination and is primarily used for performance tests of Keysight s 4 Terminal Pair LCR meters and impedance analyzers Refer to the instrument s operation service manual for the method of using this standard Applicable instrument E4980A AL E4981A E4990A Terminal connector 4 Terminal Pair BNC Dimensions approx 94 W x 31 H x 67 D mm Weight approx 120 g 42091A Short termination Lash AW kevsicnt 420914 Description The 42091A is a short termination and is primarily used for performance tests of Keysight s 4 Terminal Pair LCR meters and impedance analyzers Refer to the instrument s operation service manual for the method of using this standard Applicable Instrument E4980A AL E4981A E4990A Terminal connector 4 Terminal Pair BNC Dimensions approx 94 W x 31 H x 67 D mm Weight approx 120 g 57 Keysight Accessories Catalog for Impedance Measurements Catalog Index Model number Name 16034E SMD Chip test fixture E4980A AL E4981A E4990A E5061B 3L3 3L4 3L5 w Opt 005 16034G SMD Chip test fixture small refer to 16034E 16034H SMD Chip test fixture general refer to 16034E 16047A Axial and radial test fixture E4980A AL E4981A E4990A 16047E Axial and radial test fixture 120 MHz refer to 16034E 16048A One meter test leads BNC E4980A AL E4981A 16048D Two meter test leads BNC E4980A AL E4981A
29. 96 29030 16196 24004 16193 60002 8710 2081 8710 0909 5182 7586 16196 60450 Qty Insulator assembly amp 0 30 mm ea a ee Co ee OG en i ee Ve ees 42 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196D Parallel electrode SMD test fixture continued Options 16196D 710 Add the magnifying lens and tweezers To maintain adequate measurement performance keep the electrodes and the short plate in good condition Contaminants and abrasion on these parts considerably affect measurement results especially for low value measurements Periodic fixture cleaning and part replacement is recommended to avoid deterioration of measurement perfor mance The 16196x fixtures are designed with simplicity in mind so that an operator can easily replace parts Spare parts which are likely to be abraded are supplied with the 16196U Maintenance Kit 16196U Maintenance kit Opt 16196U 020 Upper electrode 5 piece set for 16196D Opt 16196U 400 Short plate for 01005 inch 0402 mm size 5 piece set for 16196D Opt 16196U 410 Lower electrode 5 piece set for 16196D Compensation and measurement First of all install the appropriate insulator as sembly into the fixture Then perform compensation Open and short compensations are recommended in combination with the electrical length compensation before measurement The fixture s electrical length mus
30. AC DC Operating temperature 55 to 85 C DUT size The applicable SMD size is 0603 inch 1608 mm For details see the figure below DUT insertion hole diameter DUT 1 6 0 15 mm Electrode Insulator assembly The 16196A is furnished with three different insulator assemblies since any gaps between the DUT and the cylindrical insulator will result in improper positioning and subsequent measurement errors Select an insulator assembly that reduces the gap the most See the table below for dimensions of the insulator assemblies Hole diameter of insulator SMD case size examples assembly mm Length width height mm 16196A Q 1 34 1 6 x 0 8 x 0 8 1 14 1 6 x 0 8 x 0 6 o 1 08 1 6 x 0 8 x 0 5 Furnished accessories Description P N Qty Operation and service manual 16196 90040 i Insulator assembly amp 1 34 mm 16196 60112 i Insulator assembly amp 1 14 mm 16196 60113 i Insulator assembly amp 1 08 mm 16196 60114 i Open plate 16196 29002 Short plate 16196 29026 i Push ring 16196 24004 Magnifying Lens 16193 60002 1 Tweezers 8710 2081 Wrench 8710 0909 Cleaning rod 5182 7586 i Carrying case 16196 60150 1 Opt 16196A 710 only 35 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196A Parallel electrode SMD test fixture continued Options 16196A 710 Add the magnifying lens and tweezers To maintain adequate measurement perfor
31. C bias accessories Material 16047A E 16034E G H 16334A 16089A B C 16048A D E G H 16065A C 16451B 16452A Up to 3 GHz Terminal configuration 7 mm connector Lead components SMD components DC bias accessories Material Other accessories Miscellaneous 16092A 16194A 16092A 16192A 16194A 16196A B C D 16197A 16198A 162008 16453A 16454A 16190B 16380A C 42030A 42090 1A 08 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Test fixtures 4 Terminal pair for impedance measurements up to 120 MHz Frequency range 10M 16047A 13 M 16047E 16034E 16034G H 16334A 16089A B C 16048A D 16048E 16048G H 42941A 16065A 16065C 16451B 16452A Applicable instrument Frequency Up to 120 MHz Up to 3 GHz range Terminal configuration 4 Terminal pair Terminal configuration 7 mm eG waa OG KOCIC ES S CCIC I SS O aada OG CY 6608 EG F o e EG oo Ege Measurement E4980A AL E4981A E4990A E4982A E4990A 42942A E4991B instruments E5061B 3L3 3L4 3L5 w Opt 005 16201A Option E4990A 120 Is required 09 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Lead Components 1604 A Test fixture Terminal connector 4 Terminal pair BNC DUT connection 4 Terminal Dimensions approx 124 W x 31 H x 62 D mm Weight approx 205 g Additional
32. Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16194A High temperature component test fixture continued Options 16194A 010 Add EIA EIAJ industrial standard sizedshorting bar set 16194A 701 Add general sized shorting bar set Compensation and measurement Before beginning the measurement the appropriate device holder for a SMD or lead component must be prepared with the text fixture The following figure shows how the device holder is exchanged to match the device type The next step is to perform open and short compensations in combination with the electrical length compensation When measuring above 500 MHz load compensation Device holder Remove the ground plate for SMD for leaded device When measuring SMD attach the knob on the device holder Select the device holder suitable for the device type Loosen its knob and insert into the arm Set the ground plate Exchanging the device holder is also recommended The fixture s electrical length must be entered into the electrical length compensation function of the measurement instrument first Then open com pensation is performed by separating the high and the low electrodes from each other The separation should be equivalent in size to the DUT s width Short compensation Is performed by using the option 16194A 010 701 shorting bar set Load compensation Is performed by using the furnished 50 Q SMD chip resistor After performing open
33. Keysight Technologies Accessories Catalog for Impedance Measurements Catalog KEYSIGHT TECHNOLOGIES i Keysight Accessories Catalog for Impedance Measurements Catalog Table of Contents 151446 01051010 EEE 01 1 What are Keysight Technologies accessorles wrrrrrrrvrrrrrrrrnnn 01 TEST en 01 3 The Benefits of Keysight accesSorles rrrrrrrannrrrasnnnnnnvvrvvnnnrvenn 02 4 ISO 9000 quality management rsrnrvrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrereernn 02 Tips for Selecting Appropriate ACCeSSOrleS mrmrrrrrrrrrrrrvrrrvrrrvrrrnnn 03 1 Selection by measurement APPLICATION rrrnnnnrsoooronnnrrnnnnnnnnnnnnnr 03 2 Compatibility with measurement INStrUuMEentS rrrrrrrrrrrrrrrrrrnn 03 3 Frequency DC bias and operating temperature humidity 04 4 DUT device under test GIMENSIONS ccccccceeccceccceeeeececceeeeeeeeees 04 D Open amp short repeatability and proportional error 04 FUMISNEN ESSO ES ssrin kakek ii 04 ML 05 Leese EEE 06 Applicable frequency ge 1 0 EE 06 Accessories organization nnnnrrrennnrrrannnnnnnnnnnnnrrrnnnnrssannnnnnrssnnnnrsvee 07 Up to 120 MHz 4 Terminal Pair ceesre 08 Fe 6 t A E EEE 09 NED E T 09 fe TED E 10 Pa 11 ee TeSt AG EE 11 EEE 12 EE MEG gt ER akihaha 18 16334A Tweezers contact test fixture mmmmerererrrrrrrronnnonnnnnnn 14 Other Components smrravernrennrornronovnrsnrosnvrnnrensvonnronsvnssnvesnvsnnvennrnn 1
34. L 0 1 8 0 mm Electrode Furnished accessories Description P N Qty Operating manual 16034 90041 i Compensation and measurement Open and short compensations are recommended before measurement Open compensation is performed by separating the high and low electrodes from each other The separation should be equivalent in size to the DUT s width Short compensation is performed by contacting the high and low electrodes together After performing open and short compensations the DUT is inserted into the test fixture The following figures show how compensation and measurement are performed 1 Loosen the Knob 2 Push the end of the high electrode until it touches the low electrode Ff VAM ed ML Open compensation 0 1 mm 8 0 mm NNN LL i 5 Lo es HIGH DC BIAS tom DC BIAS 1 16034E TEST FIXTURE Inserting a DUT DUT The distance between the high and low contact electrodes should the same as the DUT s width 1 Release lever and insert DUT 3 Tighten the Knob Device holder top view Measurement electrode side view Units mm Electrode dimensions 12 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair SMD continued 16034G Test fixture with Opt 005 Frequency DC to 120 MHz Operating temperature 0 to 55 C DUT size See figure below Terminal connector 4 Terminal Pair BNC L0 1 5 0mm W 0 3 1 6
35. OG 2mm Electrodes configuration and SMD size Compensation and measurement First of all select the appropriate device insertion hole If the device insertion hole is not positioned in the pressure arm s contact range reposition the device guide and the electrode plate Once this is prepared perform compensation Open and short compensations are recommended in combination with the electrical length compensation before measurement The fixture s electrical length must be entered into the electrical length compensation function of the measurement 45 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16197A Bottom electrode SMD test fixture continued instrument first Next open compensation is performed by not placing anything in the device insertion hole Short compensation is performed by placing the furnished shorting device in the device insertion hole After performing open and short compensations in combination with the electrical length compensation the DUT is inserted into the device insertion hole Once the measurement of the DUT is complete remove the DUT from the fixture The following figures show how compensation and measurement is performed Short bar Short condition DUT measurement Compensation and measurement 46 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD con
36. al Outer diameter of MUT Inner diameter of MUT Height of MUT H mm H mm 30 D x 35 24 D x 30 140g 1209 Large test fixture Small test fixture Permeability measurement method of 16454A Complex permeability is calculated from the inductance with and without the toroid When E4991B with option E4991B 002 is used as the measurement instrument direct readouts of complex permeability are possib Measurement accuracy typical In addition it Ge 002 is furnished with a small and a large fixture to adapt to a wide range of sizes Applicable instruments E4990A 42942A E4991B with Opt E4991B E4991B the operating temperature range is between 55 and 150 C The When Option E4991B 007 temperature characteristic test kit is used with temperature characteristic test kit is unavailable for the E4990A ul ER xO CTO ER ee oy ER N a ke SOD g or t S z n OL D a 4 O N OD ab Ades lt O O O 0 Srl a 3 Ioe p 5 5 2 amp a aS v ab FO o Q o Loa z LOO gt ui Frequency Hz ur Measurement accuracy Typical permeability oO Lr ik ak 1 small size Material size Frequency Hz a 3 Typical loss tangent tan 6 Measurement accuracy h In c b 10 51 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm Material continued 1645
37. by shorting the contacts of the test fixture that is in use After performing open and short compensations the DUT is connected to the test fixture Test fixture External DC 00 0000 g 90006 00100000 Oo ooocBe0 0000 E v bias source LCR meter with 16065C 22 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Material 16451B Dielectric test fixture Terminal connector 4 Terminal pair BNC Dimension approx See page 26 Cable length approx 0 8 m from connector to electrodes Weight approx 3700 g Measurement accuracy A em er accuracy gt tan 6 lt 0 1 dy Az 0 04 f2 m Eo ng A l ve rm 0 01 e Loss Tangent Accuracy A tan 6 tan amp lt 0 1 Ad Ea Eb d eck Ea 0 005 0 0004 f2E m 7 _ tan 6 AE rm Er 00 Em supplemental performance characteristics f measured frequency Hz f lt 30 MHz n measured permittivity tan 6 measured dissipation factor permittivity of air 8 854 x 10 4 F m d diameter of electrode A B t thickness of material mm Az Impedance measurement error of instrument Ad D measurement error of instrument The material is assumed to be ideally flat The above equation is applicable for electrodes A and B when using the contacting electrode method E4990A with 16451B Description The 16451B is used to evaluate
38. cated away from the measurement Instrument Probes Probes are helpful in measuring components which are already connected to PC boards or have one terminal grounded Adapters Adapters are used to adapt the dedicated circuits between the Instrument and the test fixtures The 42942A is a terminal conversion adapter that can convert a 4 Terminal Pair configuration to a 7 mm configuration The 16065C is an external DC bias adapter that can apply DC bias to the DUT from an external DC bias SOUrce Others Also available are DC bias accessories and performance test equipment 02 Keysight Accessories Catalog for Impedance Measurements Catalog Introduction continued 3 The Benefits of Keysight accessories Each accessory is designed to ensure highly accurate measurements without degrading the performance of the measurement instrument Minimum residual error preserves the accuracy of the measurement instruments Clearly defined error compensation allows easy calculation of error corrections Strict measurement specifications such as test frequencies and signal levels provide safe and accurate measurements This document introduces a group of Keysight accessories that are well suited for the following measure ment instruments LCR meters E4980A Precision LCR Meter 20 Hz to 2 MHz E4980AL Precision LCR Meter 20 Hz to 300 kHz 500 kHz 1 MHz E4982A LCR Meter 1 MHz to 300 M 500 M 1G 3 GHz Capacitance mete
39. compensation before measurement The fixture s electrical length must be entered into the electrical length compensation function of the measurement instrument first Then open compensation is performed by separating the high and the low electrodes from each other The separation should be equivalent in size to the DUT s width Short compensation is performed by using option 16192A 010 701 shorting bar set After performing open and short compensations in combination with the electri cal length compensation the DUT is inserted into the test fixture The following figures show how compensation and measurement is performed 32 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16194A High tempera ture component test fixture Terminal connector 7 mm DUT connection 2 Terminal Electrical length 50 mm Dimensions approx 150 W x 40 H x 80 D mm Weight approx 350 g Additional error SMD Type of error Impedance Proportional error 20 x f Open repeatability 80 250 x f US Short repeatability 0 2 2 5xf Q Leaded device Type of error Impedance Proportional error 20 x f Open repeatability 80 500 x f uS Short repeatability 0 44 12 5xf Q f GHz Description This test fixture is designed for measurin
40. d capacitor 16388A 16388A 10 uF 0 05 lt 0 0005 Qty A a a oa 55 Keysight Accessories Catalog for Impedance Measurements Catalog Other Accessories continued 42030A Four Terminal pair standard resistor set Description The 42030A is a standard resistor set consisting of nine precision resistor Standards which range from 1 mQ to 100 kQ These resistors are primarily used for performance tests of Keysight s 4 Terminal Pair LCR meters and impedance analyzers Refer to the instrument s operation service manual for the method of using these Standards Applicable instrument E4980A AL E4981A E4990A Model DC resistance 42031A 1mQ 0 2 42032A 10 mA 0 2 42033A 100 mO 0 2 42034A 10 0 2 Terminal connector 4 Terminal pair BNC 42035A 10 0 0 1 Dimensions approx 42036A 100 Q 0 1 94 W x 31 H x 67 D mm resistors 42037A 1 KQ 01 Weight approx 3 7 kg including case 42038A 10KO 01 and 9 resistors 42039A 100 kO 0 1 Furnished accessories Description P N Qty 42031A 1 mQ N A 42032A 10 mQ N A 42033A 100 mQ N A 1 42034A 1 0 N A 42035A 10 0 N A 42036A 100 Q N A 42037A 1 kQ N A 42038A 10 kQ N A 42039A 100 kQ N A 1 Calibration report N A Carrying case 42030 60100 i Operating and service manual 42030 90001 1 56 Keysight Accessories Catalog for Impedance Measurements Catalog Other Accessories continued 420
41. e The measurement instruments described In this guide are divided into the following three categories based on frequency Frequency Up to 120 MHz Up to 3 GHz range Terminal configuration 4 Terminal pair Terminal configuration 7 mm Measurement E4980A AL E4981A E4990A E4982A E4990A 42942A E4991B instruments E5061 B 3L3 3L4 3L5 w Opt 005 16201A Option E4990A 120 is required 04 Keysight Accessories Catalog for Impedance Measurements Catalog Tips for Selecting Appropriate Accessories continued 3 Frequency DC bias and operating temperature humidity each of the Keysight accessories has its own specific operating range Any measurement performed outside this range can Increase residual errors and can cause problems Be sure that your measurement environment fits the accessory s specific operating range In the case of humidity Keysight s accessories can operate at a relative humidity of 95 or less at 40 C These same requirements apply to most LCR Meters and Impedance Analyzers When the ambient temperature is not approximately 40 C use an accessory that has no condensation on its surface 4 DUT device under test dimensions The DUT can vary from chip components axial radial leads or ICs to general electrical materials Select a test fixture lead that is suitable for the shape and size of your components or materials 5 Open amp short repeatability and proportional error Since a test f
42. easurements Catalog Up to 120 MHz 4 Terminal Pair Other Components continued 160890 Kelvin IC clip leads Terminal connector 4 Terminal Pair BNC DUT connection 4 Terminal Cable length approx 1 3 m from connector to clip s tip Weight approx 300 g Additional error The additional error is negligible when compared to the instrument s accuracy Description This test fixture makes it possible to measure odd shaped components that cannot be measured with conventional fixtures It is equipped with two insulated Kelvin clips Applicable instruments E4980A AL E4981A E4990A Frequency 5 Hz to 100 kHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C DUT size See figure below Furnished accessories Description P N Qty Operating and service manual 16089 90020 Compensation and measurement Open and short compensations are recommended before measurement For open compensation do not connect the Kelvin clips to anything Short compensation is performed by connecting the Kelvin clips together After performing open and short compensations the DUT is held with the Kelvin clips 17 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Port Cable Extension 16048A Test leads Terminal connector 4 Terminal Pair BNC Cable length approx 0 94 m from connector to cable tip Cable tip BNC male Weight approx
43. ectrode polarization phenomenon Keysight is not responsible for any damage e g corrosion smear to the 16452A caused by the reaction between the liquid under test and the 16452A 28 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm Frequency range 16092A 16192A 16193A 16194A 16196A B C D 16197A 16198A 16200B 16453A 16454A Applicable instrument Frequency Up to 120 MHz range Terminal configuration 4 Terminal Pair Measurement E4980A AL E4981A E4990A instruments Up to 3 GHz Terminal configuration 7 mm aa ao MOOG ee PE OG e0 COCO ee E ECC OG EG Eee ER eo Gs E4982A E4990A 42942A E4991B E5061 B 3L3 3L4 3L5 w Opt 005 16201A Option E4990A 120 is required 29 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm Lead Components 16092A Spring clip fixture Description This test fixture is designed for impedance evaluation of both lead and SMD It is furnished with two modules that can be readily screwed onto the plate to measure either lead or SMD Applicable instrument E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Option E4990A 120 is required Frequency DC to 500 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C Terminal connector 7 mm DUT size See figure below DUT connection 2 Terminal Electrical length 3
44. el electrode SMDs It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements The applicable SMD size code is 01005 inch 0402 mm Applicable instrument E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Option E4990A 120 is required Frequency DC to 3 GHz Maximum voltage 42 V peak max AC DC Operating temperature 55 to 85 C DUT size The applicable SMD size is 01005 inch 0402 mm For details see the figure below DUT 0 4 0 02 mm 0 2 0 02 mm 011 to 0 22 mm Electrode DUT insertion hold diameter Insulator assembly The 16196D Is furnished with two different insulator assemblies since any gaps between the DUT and the cylindrical insulator will result in improper positioning and subsequent measurement errors Select an insulator assembly that reduces the gap the most See the table below for dimensions of the insulator assemblies Hole diameter of insulator assembly mm 16196D h 0 34 SMD case size examples Length width Height mm 0 4x0 2x 0 2 0 4 x 0 2 x 0 13 0 2 0 30 Furnished accessories Description Operation and service manual Insulator assembly amp 0 34 mm Open plate short plate Push ring Magnifying lens Tweezers Wrench Cleaning rod Carrying case 1 Opt 16196D 710 only 2 16196 15101 as replacement part number P N 16196 90040 16196 60412 16196 60414 16196 29002 161
45. error Type of error Impedance Proportional error 5 x 10 f MHz Description This test fixture is designed for impedance evaluation of axial radial lead type devices The 16047A employs Kelvin contacts which realize a wide impedance measurement range The contact tip can be changed according to the device shape Applicable instruments E4980A AL E4981A E4990A Frequency DC to 13 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C DUT size See figure with module sizes Radial lead Shor radial lead 73 37 5 2 5 E 2 ig 16047A 16047A Axial lead 24 gt A 16047A 16047A pr Unit mm 16047A module sizes Furnished accessories Description P N Qty Module for axial lead 16061 70022 2 Module for radial lead mounting on fixture 16061 70021 2 Module for short radial lead 16047 65001 2 Operating note 16047 90011 i Each module size for the 16047A Is shown above Option 16047A 701 Add Shorting plate P N 16047 00640 Compensation and measurement Select one of these modules suitable for the DUT s shape Open and short compensations are recommended before measurement Short compensation is performed by shorting the contacts of the test fixture with a shorting plate After performing open and short compensations the DUT is connected to the test fixture P N 16047 00640 Material Brass Ni dipped Thickness 1 0 mm Residual impedance 20nH 1mQ Shor
46. es In addition a variety of test leads are available to simplify remote testing and systems applications External test fixtures with safety covers are also available You will improve your measurement results with the proper test fixture More reliable and repeatable measurement Higher through put Fewer handling errors Tighter test limits Better measurement accuracy E4990A Option 010 020 030 050 E5061B Option 3L3 3L4 3L5 w 005 For additional product information and literature visit our Accessories Web site www keysight com find impedance accessory T z 5 lt lt lt lt mm oo Q 3 JESS Table 3 Test accessories fixtures 16034E SMD chip test fixture DC 40 MHz u 4 16034G SMD chip test fixture small DC 120 MHz u u 16034H SMD chip test fixture for Array type DC 120 MHz u 16047A Axial and radial test fixture DC 13 MHz o u 16047E Axial and radial test fixture DC 120 MHz u u 16048A One meter test leads BNC DC 30 MHz 8 16048D Two meter test leads BNC DC 30 MHz u 16048E Four meter test leads BNC DC 2 MHz 16048G One meter test leads BNC DC 120 MHz o 16048H Two meter test leads BNC DC 120 MHz u 16065A Ext voltage bias with safety cover lt 200 Vdc 50 Hz 2 MHz u u 16065C External bias adapter lt 40 Vdc 100 Hz 1 MHz o 16089A B C Kelvin clip leads 5 Hz 100 kHz u 4 16092A RF spring clip axial radial and SMD DC 500 MHz n a 16192A Parallel elec
47. g both axial radial leaded devices and SMD within the temperature range from 55 to 200 C when used with the E4991B 007 Temperature Characteristic Test Kit 55 to 150 C Applicable instrument E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Option E4990A 120 is required Frequency DC to 500 MHz with open and short compensation DC to 2 GHz with open and short and load compensation Maximum voltage 42 V peak max AC DC Operating temperature 55 to 200 C DUT size See figure below Electrodes 8 0 21mm lt 20 2 mm Furnished accessories Description P N Qty Wrench 8710 1181 Tweezers 8710 2081 i 5001 SMD resistor 0699 2829 10 Operation and service manual 16194 90030 i General sized Shorting device 16191 29001 i 1 x 1x 2 4 mm Shorting device 16191 29002 i 1 6 x 2 4 x 2 mm Shorting device 16191 29003 24X27 4X32 MT Shorting device 16191 29004 i 2 4 x 2 4 x 4 5 mm EIA EIAJ industrial standard sized Shorting device 16191 29005 1 x 0 5 x 0 5 mm Shorting device 16191 29006 i 1 6 x 0 8 x 0 8 mm Shorting device 16191 29007 i 2 0 x 1 2 x 0 8 mm Shoring device 16191 29008 i 3 2 x 1 6 x 0 8 mm Case for shorting devices 1540 0692 i Option Standard Standard Standard Standard 16192A 01 16192A 01 16192A 01 16192A 01 16192A 010 16192A 010 16192A 010 16192A 010 16192A 010 701 33 Keysight Accessories
48. h Opt 005 16201A Option E4990A 120 is required Frequency DC to 3 GHz Maximum voltage 42 V peak max AC DC Operating temperature 55 to 85 C DUT size See figure and table below Type of error Impedance Proportional error 1 0 x f Open repeatability 5 40 xf US Short repeatability 30 125 x f mQ f frequency GHz Pressure unit _ Electrode unit Test fixture overview Guide holder Electrodes Standard option SMD size code 3225 mm 1210 inch 3216 mm 1206 inch 2012 mm 0805 inch 1608 mm 0603 inch 1005 mm 0402 inch inch Option 16197A 001 SMD size code 0603 mm 0201 inch Furnished accessories Description Operation and service manual Device guide Electrode plate Cleaning rod Blank device guide Magnifying glass Tweezers Wrench Carrying case Applicable SMD size Lx W mm 3 22015 25015 s2 01516015 2 0 0 15 x 1 25 0 15 1 6 0 15 x 1 0 0 1 x 0 8 0 15 0 5 0 1 Applicable SMD size Lx W mm 0 6 0 03 x 0 3 0 03 P N 16197 90000 16197 25005 16197 00603 5182 7586 16197 25006 16193 60002 8710 2081 8710 0909 16197 60060 1 One is delivered attached to the test fixture 2 Delivered attached to the fixture H mm H gt 0 4 H gt 0 4 H gt 0 4 H gt 0 4 H gt 0 4 H mm H gt 0 25 Qty S 0O0O mT Nt Ite 44 Keysight Accessories Catalog for Impedance Measurements Ca
49. he DUT 1 What are Keysight Technologies accessories Keysight Technologies offers a variety of accessories suitable for many applications They are designed to make measurements simple and reliable For example a mechanically and electrically precise test fixture is required to measure the impedance of SMD components For this measurement Keysight offers dedicated SMD fixtures for impedance measurement instruments that minimize the measurement errors Also specially designed fixtures for other specific applications such as DC bias test dielectric material test and others are available Keysight accessories facilitate a shorter time to market with increased confidence by providing accurate and repeatable measurements 2 Types of accessories Keysight accessories can be divided into the following five categories Test fixtures A test fixture is used to hold the electronic components or materials physically and electrically for the measurements Keysight offers various kinds of 4 Terminal Pair test fixtures and 7 mm test fixtures Some of them connect directly to the measurement instrument while others require adapters Test leads Test leads are used to extend the measurement ports from the UNKNOWN terminals of the instrument to the DUT Using a flexible test lead a DUT that cannot be held with test fixtures can be measured regardless of its size or Shape The test leads can also be used as cable extensions when the test sample is lo
50. he gap width shall be i as small as practical oa 20 to 50 Note signifies diameter Dimensions are in millimeters Material size for electrode D Electrode type Diameter of MUT Thickness of MUT Diameter of electrode Max frequency C 96 mm t lt 10mm 9 90 mm 30 MHz D 20 mm 56 mm t lt 10 mm D 14mm 30 MHz diameter of applied thin film electrode 24 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Material continued 16451B Dielectric test fixture continued Furnished accessories Description P N Qty Test Fixture including Electrode A unguarded electrode and cover N A i Electrode B and cover 16451 60013 i Electrode C and cover 16451 60012 i Electrode D and cover 16451 60014 i Attachment for error compensation and cover 16451 60021 i Hex key for replacing electrodes 5188 4452 1 Carrying Case 16451 60001 Guarded Guard electrode Changeable _ pe 71 Ungarded electrode Note signifies diameter Dimensions are in millimeters Note Dimensions are in millimeters Dimensions of unguarded electrode Dimensions of fixture assembly A FIG gt 25 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Material continued 16451B Dielectric test fixture continued Compensation and measurement There are three measurement methods for the 16451B They are the Contacting Electrode Meth
51. ion and measurement are DC BIAS Contact pin locking screw Measurement electrode side view Units mm 13 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair SMD continued 16034H Test fixture Terminal connector 4 Terminal Pair BNC DUT connection 2 Terminal Dimensions approx 120 W x 50 H x 70 D mm Weight approx 200 g Additional error Type of error Proportional error Open repeatability short repeatablity f MHz Impedance 0 5 x f 10 5 500 x f 10 nS 10 13 x f 10 mQ Description This test fixture is designed for impedance evaluations of array type SMD The minimum SMD size that this fixture is adapted to evaluate is 1 6 L x 0 8 W mm Since the tip of the measurement electrodes are very thin and the device holder is extremely flat the device can be shifted and the measurement electrodes can contact the each element of the array type component Applicable instruments E4980A AL E4981A E4990A E5061B 3L3 3L4 3L5 with Opt 005 Frequency DC to 120 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C DUT size See figure below L 0 1 5 0 mm W lt 15 0m H 0 6 3 0mm Furnished accessories Description P N Qty Case for 100 Q SMD resistance 1540 0692 i 100 Q chip resistor 0699 2488 10 Operating manual 16034 90012 Compensation and measurement Open and short compe
52. ixture induces an additional error when measuring the total measurement error is the sum of the measurement instrument s measurement accuracy and the fixture s additional error Generally a test fixture s additional error consists of three terms open repeatability short repeatability and proportional error Open and short repeatability exhibit the error factors of the open and short residual impedances which affect the measurements of extremely high and low impedances respectively Propor tional error exhibits the error factor which is proportional to the value of the impedance being measured For more details on this subject please refer to the Appendix 6 Furnished accessories Each test fixture is shipped with a manual and various other accessories needed for measuring For example the 42941A impedance probe kit is furnished with a pin probe an adapter BNC SMA 3 spare pins a carrying case and an operation and service manual 05 Keysight Accessories Catalog for Impedance Measurements Catalog Tips for Selecting Appropriate Accessories continued 7 Terminal adapters Terminal Adapters convert the instruments terminal configuration into a 7 mm terminal configura tion This means that instruments that do not have a 7 mm terminal connector can use test fixtures with a 7 mm terminal connector The 42942A converts a 4 Terminal Pair configuration into a 7 mm terminal connector which can only be used with the E4990A 4
53. lculated from the measured capacitance in the following manner ta x Co er Relative permittivity Capacitance measurement data 8 854 x 10 14 F m t Average thickness of test material d Diameter of guarded electrode 26 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Material continued 16452A Liquid dielectric test fixture i Description This test fixture provides accurate dielectric constant and impedance measurements of liquid materials The 16452A employs the parallel plate method which sandwiches the liquid material between two electrodes to form a capacitor A LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixture Applicable instruments E4980A AL E4990A Frequency 20 Hz to 30 MHz Operating temperature 20 to 125 C Maximum voltage 30 Vrms Material capacity Required sample liquid capacity depends on the gap of the electrodes Gap of electrodes 0 3 mm 0 5 mm 1 mm 2 mm i i 0 0 0 0 Terininaleonnectors terminal ean Suk Air capacitance 34 4 DF 20 Z 20P lo 1090 S 5 0r 210 Dimensions approx 8 Sample liquid capacity 3 4 ml 3 8 ml 4 8 ml 6 8 ml 5 H x 85 W x 37 D mm Applicable frequency 20 Hz 30 MHz Weight approx 1400 g Measurement accuracy A B C Error A y F E 3 10 30 100 lerm Fixture error A Furnished accessories
54. mance keep the electrodes and the short plate in good condition Contaminants and abrasion on these parts considerably affect measurement results especially for low value measurements Periodic fixture cleaning and part replacement is recommended to avoid deterioration of measurement perfor mance The 16196x fixtures are designed with simplicity in mind so that an operator can easily replace parts Spare parts which are likely to be abraded are supplied with the 16196U Maintenance Kit 16196U Maintenance kit Opt 16196U 010 Upper electrode 5 piece set common to 16196A B C models Opt 16196U 100 Short plate for 0603 inch 1608 mm size 5 piece set for 16196A Opt 16196U 110 Lower electrode 5 piece set for 16196A Compensation and measurement First of all install the appropriate insulator as sembly into the fixture Then perform compensation Open and short compensations are recommended in combination with the electrical length compensation before measurement The fixture s electrical length must be entered into the electrical length compensation function of the measurement instrument first Next open compensation is performed by placing the furnished open plate on top of the insulator assembly Short compensation is performed by placing the furnished shorting plate on top of the insulator assembly After performing open and short compensations in combination with the electrical length compensation the DUT Is inserted into the
55. ng devices Magnifying lens Tweezers 16191 29008 1540 0692 16193 60002 8710 2081 16192A 010 16192A 010 701 16192A 710 16192A 710 31 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16192A Parallel electrode SMD test fixture continued Length positioning stage Device stage Length locking knob Magnifying lens Is set here Device holder Width positioning knob Width positioning stage Insertion clip Device scale Electrodes Device holder adjustment Test fixture overview a Place the shorting device DUT so that it contacts the electrode b Adjust the two knobs and the two device holders to hold the shorting device DUT c Tighten knob while pushing the lever d Release the lever to hold the shorting device DUT Perform short compensation or measure the DUT e Set the DUT on the test fixture just as you set the shorting device in the SHORT compensation f Push the black lever and remove the DUT Perform open compensation For more details please refer to 16192A operation manual Open short compensation Options 16192A 010 Add EIA EIAJ industrial standard sized shorting bar set 16192A 701 Add general sized shorting bar set 16192A 710 Add the magnifying lens and tweezers Compensation and measurement Open and short compensations are recommended in combination with the electrical length
56. nsations are recommended before measurement When measuring above 3 MHz load compensation is also recommended Open compensation is performed by separating the high and the low electrodes from each other The separation should be equivalent in size to the DUT s width Short compensation is performed by placing the high and low electrodes in contact together Load compensation is performed by using the furnished 100 Q SMD chip resistor After performing open short and load compensations the DUT is inserted into the test fixture Refer to the 16034G figures to see how compensation and meas urement are performed Device holder Measurement electrode top view side view Units mm Electrode dimensions 14 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair SMD continued 16334A Tweezers contact test fixture Terminal connector 4 Terminal Pair BNC DUT connection 2 Terminal Cable length approx 1 m from BNC connectors to the top of tweezers Weight approx 290 g Additional error Type of error Proportional error f MHz Impedance 2 x f 10 Description This test fixture is designed for impedance evaluations of SMD The minimum SMD size that this fixture is adapted to evaluate is 1 6 L x 0 8 W mm The tweezers contacts on this fixture makes It easy to hold the DUT Applicable instruments E4980A AL E4981A E4990A Frequency 5 Hz
57. od used with 16451B s rigid metal electrode without any electrodes on the material under test the Contacting Electrode Method used with thin film electrodes made on the material under test and the Non Contacting Electrode Air Gap method Select the suitable measurement method and the suitable electrode for the material under test according to the following table Summary of measurement method Measurement Contacting electrode method used with Contacting electrode method used Non contacting electrode method method rigid metal electrode with thin film electrode Accuracy Low gt High Operation simple gt Complex Applicable Thick solid and smooth materials Materials on which thin film can Thick and soft materials Rough materials be applied without changing its materials also characteristics Open and short compensations are recommended in combination with the cable length compensation before measurement When measuring above 5 MHz with the E4990A load compensation is also recommended First set the instrument s cable length compensation function to I m Then open and short compensation is performed by using the furnished electrode attachment Load compensation is performed by prepar ing a working standard After performing open short and load compensations the MUT is sandwiched by the parallel electrodes and the capacitance is measured Relative permittivity is ca
58. onnection 2 Terminal Electrical length 11 mm Dimensions approx 150 W x 70 H x 90 D mm Weight approx 400 g Additional error Type of error Impedance Proportional error 1 5 x f Open repeatability 2 30xf pS Short repeatability 30 250 x f mQ f GHz Description This test fixture is designed for impedance evaluations of parallel electrode SMD The minimum SMD size that this fixture is adapted to evaluate is 1 L mm Applicable instrument E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Option E4990A 120 is required Frequency DC to 2 GHz Maximum voltage 42 V peak max AC DC Operating temperature 55 to 85 C DUT size 1 mm to 20 mm length L 1 0 to 20 mm W 0 5 to 5 mm H 0 5 to 5 mm Electrodes Furnished accessories Description P N Qty Option Operation and service manual 16192 90040 i Standard General sized Shorting device 16191 29001 16192A 01 1 x 1x 2 4 mm Shorting device 16191 29002 i 16192A 01 1 6 x 2 4 x 2 mm Shorting device 16191 29003 16192A 701 2 4x 2 4 x 3 2 mm shorting device 16191 29004 i 16192A 701 2 4x 2 4 x 4 5 mm EIA EIAJ industrial standard sized Shorting device 16191 29005 i 16192A 010 1 x 0 5 x 0 5 mm Shorting device 16191 29006 i 16192A 010 1 6 x 0 8 x 0 8 mm Shorting device 16191 29007 16192A 010 2 0 x 1 2 x 0 8 mm Shoring device 3 2 x 1 6 x 0 8 mm Case for shorti
59. rs E4981A Capacitance Meter Impedance analyzers E4990A Impedance Analyzer 20 Hz to 10 20 30 50 120 MHz E4991B Impedance Analyzer I MHz to 500 MHz 1 GHz 3 GHz Network analyzer E5061B 3L3 3L4 3L5 LF RF Network Analyzer 5 Hz to 500 M 1 5 G 3 GHz 4 ISO 9000 quality management ISO 9000 is a set of international standards for quality management and quality assurance These standards were developed with the goal of documenting and implementing effective quality systems within companies ISO standards are consistent with Keysight s quality system in fact the standards within Keysight Technolo gies Quality Maturity System QMS exceed the intent of ISO 9000 03 Keysight Accessories Catalog for Impedance Measurements Catalog Tips for Selecting Appropriate Accessories The following topics comprise a helpful guideline for selecting an appropriate accessory for the measurement instrument to be used 1 Selection by measurement application Keysight accessories can be used in a wide variety of measurement applications These applications range from basic measurements such as impedance measurements for discrete devices to advanced measurements such as measurement of resistivities or dielectric constants 2 Compatibility with measurement instruments Test fixtures leads are compatible with the measurement instruments when they have the same type of terminal configuration and useable measurement frequency rang
60. ssembly Hole diameter of insulator SMD case size examples assembly mm Length width height mm 16196C o 0 48 OG 0 3 0 3 Furnished accessories Description P N Qty Operation and service manual 16196 90040 i Insulator Assembly amp 0 48 mm 16196 60312 i Open plate 16196 29002 i Short plate 16196 29028 i Push ring 16196 24004 Magnifying lens 16193 60002 1 Tweezers 8710 2081 1 Wrench 8710 0909 Cleaning rod 5182 7586 i Carrying case 16196 60350 1 Opt 16196C 710 only 40 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196C Parallel electrode SMD test fixture continued Options 16196C 710 Add the magnifying lens and tweezers To maintain adequate measurement performance keep the electrodes and the short plate in good condition Contaminants and abrasion on these parts considerably affect measurement results especially for low value measurements Periodic fixture cleaning and part replacement is recommended to avoid deterioration of measurement perfor mance The 16196 x fixtures are designed with simplicity in mind so that an operator can easily replace parts Spare parts which are likely to be abraded are supplied with the 16196U Maintenance Kit 16196U Maintenance kit Opt 16196U 010 Upper electrode 5 piece set common to 16196A B C models Opt 16196U 300 Short plate for 0201 inch O603 mm size 5 piece set for 16196C Opt 16196U 3
61. t plate in good condition Contaminants and abrasion on these parts considerably affect measurement results especially for low value measurements Periodic fixture cleaning and part replacement is recommended to avoid deterioration of measurement perfor mance The 16196x fixtures are designed with simplicity in mind so that an operator can easily replace parts Spare parts which are likely to be abraded are supplied with the 16196U Maintenance Kit 16196U Maintenance kit Opt 16196U 010 Upper electrode 5 piece set common to 16196A B C models Opt 16196U 200 Short plate for 0402 inch 1005 mm size 5 piece set for 16196B Opt 16196U 210 Lower electrode 5 piece set for 16196B Compensation and measurement First of all install the appropriate insulator as sembly into the fixture Then perform compensation Open and short compensations are recommended in combination with the electrical length compensation before measurement The fixture s electrical length must be entered into the electrical length compensation function of the measurement instrument first Next open compensation is performed by placing the furnished open plate on top of the insulator assembly Short compensation is performed by placing the furnished shorting plate on top of the insulator assembly After performing open and short compensations in combination with the electrical length compensation the DUT is inserted into the test fixture Once the measurement of
62. t be entered into the electrical length compensation function of the measurement instrument first Next open compensation is performed by placing the furnished open plate on top of the insulator assembly Short compensation is performed by placing the furnished shorting plate on top of the insulator assembly After performing open and short compensations in combination with the electrical length compensation the DUT is inserted into the test fixture Once the measurement of the DUT is complete remove the DUT from the fixture by using the furnished push ring Refer to the 16196A figures to see how compensation and measure ment is performed 43 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16197A Bottom electrode SMD test fixture Terminal connector 7 mm DUt connection 2 Terminal Electrical length 14 mm Dimensions approx 160 W x 70 H x 86 D mm Weight approx 300 g Additional error Description This test fixture is designed for impedance evaluations of bottom electrode SMDs It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements This test fixture supports various SMD sizes as small as 1005 mm 0402 inch and as large as 3225 mm 1210 inch Accommodation of the 0603 mm 0201 inch size is available with option 001 Applicable instrument E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 wit
63. talog Up to 3 GHz 7 mm SMD continued 16197A Bottom electrode SMD test fixture continued EIA EIAJ Size shorting bar set furnished Size P N Qty 1 x 0 5 x 0 5 mm 16191 29005 1 6 x 0 8 x 0 8 mm 16191 29006 2 0 x 1 2 x 0 8 mm 16191 29007 3 2 x 1 6 x 0 8 mm 16191 29008 Device Guide 16197 25007 1 Electrode Plate 16197 00604 i 16197A 001 Shorting bar Size P N Qty 0 6 x 0 3 x 0 3 mm 16197 29001 4 Options 16197A 001 Add 0603 mm 0201 inch Device guide set The 16197A s electrode spaces are 0 5 mm 1 mm 1 5 mm and 2 mm and the device guide matches these spaces with appropriate insertion holes for the applicable SMD The 0 2 mm electrode spacing is available with option 001 which includes a device guide with 0603 mm 0201inch insertion holes an electrode plate and 4 shorting devices Electrode plate outer electrode fo D J 0 Q Center electrode Standard 0603 mm 0201 inch size Standard 0603 mm 0201 inch size Option 16197A 001 Option 16197A 001 Device guide Device guide for Electrode plate Electrode plate for Shows the relative position of the SMD size Shows the relative positions of the SMD size and the DUT insertion holes and the electrode spacings SMD Size Spacings 0402 inch 1005 mm 0 5 mm 0603 inch 1608 mm 1mm 0805 inch 2012 mm 1 5mm 1206 inch 3216 mm 1210 inch 3225 mm 0201 inch 0603 mm 0 2mm Space between the center and outer electrodes
64. ter Contact board Guide PCA 0201 100 micrometer 0201 Short bar 5 piece set Weight 509 Weight 100 g Weight 200 g Standard set 0402 Contact board Guide PCA 0402 100 micrometer 0402 Short bar 5 piece set Weight 50 g Weight 100 g Weight 200 g 16198A 200 Note A standard set of either 0201 or 0402 can be ordered but not both If necessary the parts can be ordered individually H mm gt 0 11 gt 0 1 Qty a a oe a a M eS ee ee ry 47 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16198A Bottom electrode SMD test fixture continued Optional accessories P N Contact board Guide PCA 0201 70 micrometer 16198A 101 Contact board Guide PCA 0201 100 micrometer 16198A 102 Contact board Guide PCA 0402 100 micrometer 16198A 201 0201 Short bar 5 piece set 16198A 110 0402 Short bar 5 piece set 16198A 210 Weight 50 g 16198A 520 Weight 100 g 16198A 521 Weight 200 g 16198A 522 Carrying case 16198A 530 Torque driver 16198A 531 User manual English 16198A ABA User manual Japanese 16198A ABJ Retrofit service parts P N Contact board Guide PCA 0201 70 micrometer 16198AU 101 Contact board Guide PCA 0201 100 micrometer 16198AU 102 Contact board Guide PCA 0402 100 micrometer 16198AU 201 Contact board 8 piece set Guide PCA 0201 70 micrometer 16198AU 103 Contact board 8 piece set Guide PCA 0201 100 micrometer 16198AU 104 Contact board 8 piece set
65. test fixture Once the measurement of the DUT is complete remove the DUT from the fixture by using the furnished push ring The following figures show how compensation and measurement is performed 36 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196A Parallel electrode SMD test fixture continued Compensation and measurement Open compensation Short compensation DUT measurement Removing a DUT 37 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 3 GHz 7 mm SMD continued 16196B Parallel electrode SMD test fixture Terminal connector 7 mm DUT connection 2 Terminal Electrical length 26 9 mm Dimensions approx 140 W x 48 H x 78 D mm Weight approx 250 g Additional error Type of error Impedance Proportional error 1 0 x f Open repeatability 5 40xf US Short repeatability 30 125 x f mQ f frequency GHz Description This test fixture is designed for impedance evaluations of parallel electrode SMDs It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements The applicable SMD size code is 0402 inch 1005 mm Applicable instrument E4982A E4990A 42942A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Option E4990A 120 is required Frequency DC to 3 GHz Maximum voltage 42 V peak max AC DC Operating temperature 5
66. the dielectric constant of solid dielectric materials accurately and complies with ASTM D150 The 16451B employs the parallel plate method which sandwiches the material between two electrodes to form a capacitor LCR meter or an Impedance Analyzer is then used to measure the capacitance created from the fixture A measurement block diagram of the parallel plate method is shown below Guarded electrode Guarded electrode Lines of electric force Stray Unguard capacitance electrode Parallel plate method Notice the stray capacitance which is formed on the test material as shown in the figure above The guard electrode helps to eliminate the stray capacitance at the edge of the electrode Basic measurement accuracy including the E4990A Typical Permittivity r Measurement Accuracy Aer er T i ha NUT I 100 k 1M 10M 30M 10k 100 k 10M 30M Hz Frequency Hz E4990A Measurement settings 1 Osc level 500 mV 2 Meas Time 5 Precise 3 Adapter setup 1 m 4 Compensation Open short and load
67. ting plate 10 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Lead Components continued 1604 E Test fixture Description This test fixture is designed for impedance evaluation of lead type devices up to 120 MHz A guard terminal is available for three terminal devices and a shorting plate comes secured on this fixture Applicable instruments E4980A AL E4981A E4990A E5061B 3L3 3L4 3L5 with Opt 005 Frequency DC to 120 MHz Maximum voltage 42 V peak max AC DC Operating temperature 20 to 75 C Terminal connector 4 Terminal Pair BNC DUT size See figure below with 16047E s electrode size DUT connection 2 Terminal Dimensions approx Guard terminal 135 W x 40 H x 65 D mm Weight approx 200 g Additional error Type of error Impedance Proportionalerror 0 2 x f 10 f lt 15 MHz Top view Side view Proportionalerror 4x f 100 MR ne f gt 15 MHz Open repeatability 2 n 10 ux f 100 S Short repeatability 2 m 600 m x f 100 Q Furnished accessories f MHz Description P N Qty Angle right side 16047 01221 1 Angle left side 16047 01222 1 Screws 0515 1229 4 Shorting plate 16047 00621 i Operating and service manual 16047 90040 Compensation and measurement Open and short compensations are recommended before measurement Short compensation is performed by shorting the contacts of the test fixture with a shorting
68. ting temperature 20 to 150 C Furnished accessories Description P N Qty Mounting plate N Terminal connector 4 Terminal pair BNC OOO ee Operating and service manual 16048 90050 i Cable length approx 2 m Cable tip BNC female Options Weight approx 690 g 16048H 001 Add BNC Bracket P N 16048 60003 Additional error For detailed information Here the BNC Bracket refers to the terminal board with four BNC m connectors refer to the operation manual or the Compensation and measurement Adapter setup is recommended before measurement specifications of E4990A In the adapter setup menu select 4TP 2M Then use the 100 Q resistor furnished with the E4990A to perform phase compensation and load data measurement 20 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Probes 42941A Impedance probe kit Terminal connector 4 Terminal pair BNC Cable length approx 1 5 m Weight approx 2400 g Basic measurement accuracy 1 For detailed information refer to the operation manual or the specifications of E4990A 120 E4990A 120 with 42941A Open compensation Short compensation Description This impedance probe kit is designed for use with the E4990A 120 It provides the capability to perform in circuit measurements printed circuit patterns the input output impedance of circuits etc with better accuracy and wider impedance co
69. tinued 16198A Bottom electrode SMD test fixture Terminal connector 7 mm DUt connection 2 Terminal Dimensions approx 145 W x 80 D x 110 H mm Weight approx 870 g with weight of 300 g Additional error Error factor Formula Proportional error 1 2 x f Open repeatability 5 40xf uS Short repeatability 60 125xf mQ f frequency GHz Weight Contact board D Contact board DUT cover ee Bottom side of short bar Short bar marker 0201 0402 Contact board Description This test fixture is designed for impedance evaluations of bottom electrode SMDs It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements This test fixture supports two SMD sizes 0201 mm 008004 inch and 0402 mm 01005 inch Applicable instrument E4982A E4991B E5061B 3L3 3L4 3L5 with Opt 005 16201A Frequency DC to 3 GHz Maximum voltage 40 V peak max AC DC Operating temperature 55 to 85 C DUT size See figure and table below Electrodes Standard option Applicable SMD size SMD size code L mm W mm 0402 mm 01005 inch 0 38 to 0 42 0 02 0 18 to 0 22 0 02 0201 mm 008004 inch 0 2 to 0 25 0 013 0 1 to 0 125 0 013 Furnished Accessory Description P N Cleaning rod 5182 7586 Optional accessories Standard set P N Standard set 0201 16198A 100 Contact board Guide PCA 0201 70 microme
70. to 15 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C DUT size lt 10 mm width See figure below Electrodes Furnished accessories Description P N Qty Compensation block 16334 60001 i Operating note 16334 90000 i Compensation and measurement Open and short compensations are recommended before measurement Open and short compensations are performed by using the furnished compensation block After performing open and short compensations the DUT is sandwiched by the tweezers contacts and is measured 15 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Other Components 16089A Large Kelvin clip leads Description This test fixture makes it possible to measure odd shaped components that cannot be measured with conventional fixtures It is equipped with two insulated Kelvin clips Applicable instruments E4980A AL E4981A E4990A Frequency 5 Hz to 100 kHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C DUT size See figure below Terminal connector 4 Terminal Pair BNC DUT connection 4 Terminal Cable length approx 0 94 m from connector to clip s tip Weight approx 300 g Additional error The additional error is negligible when compared to the instru Description P N Qty ment s accuracy Operating and service manual 16089 90020 1 Approx 65 mm Furnished accessories
71. trode SMD test fixture DC 2 GHz nl a 2 16194A High temperature component test fixture DC 2 GHz nl a 2 16196A B C D Parallel electrode SMD test fixture DC 3 GHz al a n n 16197A Bottom electrode SMD test fixture DC 3 GHz al a 16198A Bottom electrode SMD test fixture DC 3 GHz a 16200B External DC bias adapter 1 MHz 1 GHz al a n 16201A N type to 7 mm terminal adapter 5 Hz to 3 GHz o 16334A SMD chip tweezers test fixture DC 15 MHz u u 16451B Dielectric material test fixture DC 30 MHz u u 16452A Liquid test fixture 20 Hz 30 MHz u 16453A Dielectric material test fixture 1 MHz 1 GHz at 16454A Magnetic material test fixture 1 kHz 1 GHz a at 42941A Impedance probe kit DC 120 MHz 42942A Four terminal pair to 7 mm adapter DC 120 MHz n Note Refer to the accessory descriptions for frequency and operational limits 1 3 5 mm M to 7 mm adapter is required 42942A is required Compatible when used in conjunction with 16201A E4991B 002 is required E4980AL only Ol ge tS 60 Keysight Accessories Catalog for Impedance Measurements Catalog Keysight Web Resources LCR Meters Impedance Analyzers www keysight com find impedance Accessories for Impedance Measurements www keysight com find impedance accessory RF and Microwave Test Accessories www keysight com find mta 61 Keysight Accessories Catalog for Impedance Measurements Catalog Evolving Since 1939 Our unique combination of hardware soft
72. ual 16048 90031 Compensation and measurement Cable length compensation is recommended before measurement Set the instrument s cable length compensation function to 2 m 18 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Port Cable Extension continued 16048E Test leads Terminal connector 4 Terminal Pair BNC Cable length approx 3 8 m from connector to cable tip Cable tip BNC male Weight approx 690 g Additional Error For detailed information refer to the measurement instrument s specifications Description The test leads extend the measurement port with a 4 Terminal Pair configuration It is provided with a BNC female connector board to allow the attachment of user fabricated test fixtures Applicable instruments E4980A AL Frequency DC to 2 MHz Maximum voltage 42 V peak max AC DC Operating temperature 0 to 55 C Furnished accessories Description P N Qty Terminal board with BNC f x4 16032 60071 1 Operating manual 16048 90041 i Compensation and measurement Cable length compensation is recommended before measurement Set the instrument s cable length compensation function to 4 m 19 Keysight Accessories Catalog for Impedance Measurements Catalog Up to 120 MHz 4 Terminal Pair Port Cable Extension continued 16048G Test leads Description The test leads extend the measurement port with a 4 Terminal Pair
73. ve a 7 mm measurement terminal Refer to the instrument s operation service manual for the method of using these standards Applicable instrument E4982A E4990A 42942A E4991B Option E4990A 120 is required Furnished accessories Description Airline 50 Q 7 mm 50 Q termination Short termination Carrying case Calibration report P N N A 1401 0123 N A N A N A 16190 25011 8710 1770 N A N A N A 16190 90020 Qty Cap Protection Open termination Cap termination protection Wrench 1 2 and 8 15 open end Floppy diskette for calibration data Operating note 53 Keysight Accessories Catalog for Impedance Measurements Catalog Other Accessories continued 16380A Standard capacitor set for the method of using these standards Applicable instrument E4980A AL E4981A E4990A 16381A 16382A Capacitance 1 pF 10 pF Nominal accuracy 0 10 Calibration stability lt 300 ppm year Terminal connector 4 Terminal Pair BNC MOUN 0 S S SS a a Dimensions approx 142 W x 88 H x 112 D mm Furnished accessories capacitors Weight approx 8 0 kg including case Description P N and 4 capacitors 16381A 1 pF N A 16382A 10 pF N A 16383A 100 pF N A 16384A 1000 pF N A BNC f f Adapters 1250 0080 Calibration report N A Carrying case 16380 85101 Description The 16380A is a standard capacitor set consisting of four precision capacitors 1 pF 16381A 10 pF 16382A 100 pF
74. verage from 20 Hz to 120 MHz DUTs can be connected by either using the pin probe the clip lead alligator clip adapter or the BNC adapter All probe adapter can be used from 20 Hz to 120 MHz The pin probe is best for in circuit board mounted compo nents The clip lead is for components too large for the pin probe The BNC adapter is used to connect circuits or networks equipped with BNC connectors Applicable instrument E4990A 120 Frequency 20 Hz to 120 MHz Maximum voltage 42 V peak max AC DC Operating temperature 20 to 75 C probe only Furnished accessories Description P N Qty Pin probe 42941 60002 Adapter BNC SMA 1250 2375 Spare pin Set 3 ea 42941 60004 1 3 5 mm SHORT 1250 2840 3 5 mm LOAD 0955 1105 Clip lead 8121 0003 Ground lead 04193 61679 i Carrying case 42941 60011 Operating and service manual 42941 90010 i Compensation and measurement Adapter setup and compensation Is required before measurement In the Adapter setup menu select PROBE 42941A Use the furnished 3 5 mm short and load standards The open condition can be created by not connecting the probe to anything Perform phase compensation short and load data measure ments For compensation open and short compensation is recommended Short compensation is performed by shorting the probe To short the probe it is recommended to use a shorting device with gold plated surfacing which provides stable contact resistance 42941A
75. ware services and people can help you reach your next breakthrough We are unlocking the future of technology From Hewlett Packard to Agilent to Keysight myKeysight KEYSIGHT SERVICES Accelerate Technology Adoption Lower costs myKeysight www keysight com find mykeysight A personalized view into the information most relevant to you www keysight com find emt_product_registration Register your products to get up to date product information and find warranty information Keysight Services www keysight com find service Keysight Services can help from acquisition to renewal across your instrument s lifecycle Our comprehensive service offerings one stop calibration repair asset management technology refresh consulting training and more helps you improve product quality and lower costs Keysight Assurance Plans www keysight com find AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification So you can rely on accurate measurements Keysight Channel Partners www keysight com find channelpartners Get the best of both worlds Keysight s measurement expertise and product breadth combined with channel partner convenience www keysight com find impedance accessory KEYSIGHT TECHNOLOGIES For more information on Keysight Technologies products applications or services please contact your local Keysight office The complete list is
76. y 7 mm SMD Coaxial 16196C Parallel 3 GHz 0603 size only SMD Coaxial 19196D Parallel 3 GHz a 0402 size only SMD General 16197A Bottom 3 GHz n u 1005 to 3225 sizes only SMD General 16197A 001 Bottom 3 GHz n n n u 0603 to 3225 sizes only SMD General 16198A Bottom 3 GHz u 0201 to 0402 sizes only Notes 1 LF 4TP denotes test fixtures for use with four terminal pair type LCR meters and LF impedance analyzers in low freugncy region lt 120 MHz 2 RF 7 mm denotes test fixtures for use with RF impedance measureemnt instruments which have 7 mm coaxial test port 3 Tweezers type test fixture with 1 meter test leads 4 Test fixture for measuring SMD and leaded components 5 Check marks in the table denote the application DUT sizes 6 Applicable to SMD components with thickness gt 0 65 mm Not suitable for smaller SMD than 1608 type 7 Minimum SMD size is not specified Not recommended for smaller than 1608 type because contact repeatability degrades with the reduction of device size Zs Ve HI I Parallel electrode Bottom electrode 59 Keysight Accessories Catalog for Impedance Measurements Catalog Index continued Accessories vs Instruments matrix Simplify and improve your measurements with Keysight s test accessories Selecting a test fixture is as important as selecting the right instrument Keysight offers a wide range of accessories for axial radial and SMD Chip devic

Download Pdf Manuals

image

Related Search

5965 4792E

Related Contents

  Inscripción de Estudiantes - Centro de Lenguas    取扱説明書  Sony CMT-NEZ7DAB Speaker System User Manual  CAMSET29 - FuturaShop  Fujitsu PRIMERGY RX2520 M1  Manuel d`utilisation Imprimante PA-223 - TAG  共 栄 社  Verti Seed 804  

Copyright © All rights reserved.
Failed to retrieve file