2. List Node Controller names Active and Configured Use a different name for a new Node Controller AddANC ERROR invalid device network device Configuration error List Node Controller names Active and Configured Use a different name for a new Node Controller Reset Node Controllers lt name gt bad ANC name Configuration error List Node Controller names Active and Configured Use a different name for a new Node Controller Reset Node Controllers lt name gt no redundant ANC on line Configuration error List Node Controller names Active and Configured Use a different name for a new Node Controller Reset Node Controllers lt name gt no ANC matched Configuration error List Node Controller names Active and Configured Use a different name for a new Node Controller Reset Node Controllers lt name gt no CNC by this name Configuration error List Node Controller names Active and Configured Use a different name for a new Node Controller Reset Node Controllers lt name gt switch did not occur for unknown reason Configuration error List Node Controller names Active and Configured Use a different name for a new Node Controller Reset Node Controllers SyncANCmsgWindow WARNING window is zero Extremely busy communications bus Node Controllers cycling on and offline If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or
3. NETEDESTRCTFAIL Backup MCPU config destruct failed When attempting to create a new configuration during integration of backup MCPU removal of the old backup MCPU configuration failed Restart the backup MCPU and try again Also try re sending new configuration from PC NETEMEZLOST System lost mezzanine MCPU has lost communication with a mezzanine The system will switchover to redundant hardware if present replace mezzanine if indicated If switchover fails reset MCPU NETEDESTRCTTMO Backup MCPU config destruct timed out When attempting to create a new configuration during integration of backup MCPU removal of the old backup MCPU configuration failed Restart the backup MCPU and try again Also try re sending new configuration from PC NETECANTINTEGRT Unable to integrate MCPUs The system failed to synchronize the state of the primary and backup MCPUs The backup MCPU board will be integrated with the primary ie config transfer etc if the following criteria are met Force integration flag is True default is False Primary MCPU integration flag is TRUE Default is True backup MCPU integration flag is TRUE Default is True Primary boot ROM version date is the same as the secondary boot ROM version date Primary application version date is the same as the secondary application version date Primary console spec console ini is the same as the secondary console spec Primary slip spec slip ini only used with SMS V64x
4. Versi software on that Node Controller ersion gt Get Used alone to view date and time settings gt h Help Used alone to view general system help Used preceding h anc specific commands to view information about that command specifically inuse Inuse Used to list TieLine usage information ls inuse tl krtr Kaleidoscope Used alone or as a modifier following Is list to view the ls krtr or pr or Kadenza number limit names and order of assignment of Kaleidoscope krtr KISS VISS Router or Kadenza interfaces Used as a modifier following pr print and followed by the specific interface name to view input assignments within that interface lm save default lm save severity 1m severity Limit Save Default Limit Save Severity Limit Severity Saves the current exception severity limit for exception display as the default used after system initialization See Diagnostic Messages later in this section Saves the current exception severity limit for exception display as the system default used during system initialization See Diagnostic Messages later in this section Used alone to list current exception severity limit for exception display Used followed by severity level name off or default to set level disable system or set default See Diagnostic Messages later in this section lm save default lm save severity view setting lm severity set limit to Error lm severity error logou
5. the system will attempt to load the new file signaling an alert only when memory is actually used up and thereby increasing any system downtime involved in loading the new configuration See Recovery Procedure When Flash Memory is Overfilled in Section 4 prog Command In addition to the information in Table 5 1 on page 5 6 the following applies to the prog command For example control panel device type would be cp control panel subtype might be bps button per source ucp universal control panel mb8 multibus 8 umd1 2 or 3 under monitor displays 129 cubicle or studio panel or 130 machine control only You can list programs by entering Is prog ALL of the same type devices connected to the MCPU will be programmed with each use of this command This command may be used in software upgrades FileName The name of the hexadecimal hex file to be downloaded It MUST be in Motorola hex format Any valid path may be specified If none is the default path is FMO The quotation marks should be used The parser may have difficulty with periods and paths DeviceType The name of the device type to be programmed Default names are cp or panel and nc If the name of the device to be programmed is not recognized the numeric value must be used Entering the program command without this argument will display the list of valid type names a dummy filename may be entered Device Subtype The name of the device subtype to be programmed
6. If the name of the device type to be programmed is not recognized the numeric value must be used Entering the program command without this argument will display the list of valid type names a filename and device type must be entered If the device type is nc node controller the subtype need not be entered it defaults to subtype 0 The subtype is required for control panels Note All command line parse errors are reported and the usage syntax is displayed For any error in the device type or subtype argument a context sensitive list of valid tokens are also displayed Other errors such as missing or wrong format file are reported and the command is aborted Progress reports are displayed during programming The system diagnostic prompt will not be re displayed until programming is complete Once programming is started for any device there is a 15 second time out for programming messages This means that if the device fails during programming and does not respond you will have to wait up to 15 seconds for a response slot Command In addition to the information in Table 5 1 on page 5 6 the following applies to the slot command The slot command may also be used to download a file into a specified Mezzanine board SMS7000 gt slot slot mez mez mezname gsc asy file Where slot is the number of the CIF frame slot mez is the number of the Mezzanine board to be affected mezname is the Mezzanine board name gsc means the Mezzanine bo
7. 64 systems is the same as the secondary slip spec Primary MCPU mezzanine IDs is the same as the secondary MCPU mezzanine IDs If the above criteria is not met the exception NETECANTINTEGRT will be created when the primary MCPU attempts to integrate the backup MCPU The following system diagnostic commands are provided to override this policy integration lt on off gt This command turns on or off True False the MCPU integration flag If either MCPU integration flag is False the MCPUs will not be integrated This setting is temporary and defaults to True after a reset fintegration lt on off gt This command turns on or off True False the force integration flag on the primary MCPU Additionally it attempts to start an integration process If this flag is True integration will take place regardless of any other above criteria This setting is temporary and defaults to False after a reset The configurations stored in Flash or RAM are not a criteria for integration NETEUNKNWNORGNET Bad originating network The system software found a bad value for a network address The system is in an unusual state Check too see if the system was unusually busy for some reason are devices getting deleted and added back are there lots s of takes 100 s You may want to try to switch to any redundant hardware to see if the problem occurs again If the problems continues reset the MCPU Check software and hardware revisions Reload indicated
8. Commands and Queries Table 5 1 Diagnostic Terminal Commands Command Meaning Usage SMS7000 gt acc Alarm Statistics Used alone to clear all alarm relays and statistics Also see acc Clear arc alarm Alarm Used alone to list configured alarms Used as a modifier ls alarm following Is list to list each alarm and details about its configuration ahora Asynchronous Used as a modifier following Is list to Active Mezzanine ls amezi Mezzanine Networks with a brief summary of their configuration anc Active Node Used alone or preceded by Is list to list Active Node ls anc Controller Controller modules in the system Used with rename rename and renamebyaddr rename by address to rename Active Node Controller modules arc Alarm Clear Used alone to clear all alarm relays Also see acc arc art Alarm Test Used alone to test alarm relays After the test the alarms are a t cleared statistics remain unchanged ae Alarm Status Used alone to list configured alarms number of occurrences 5 and assignment Major Minor Proc assign Assign Used with Destination and Source names to assign a Source assign DestName to a Destination This is not a Take operation but rather an SrcName implementation of an Assignment System if it has been configured using the GUI An assignment system allows specified sources to be assigned to a destination or destinations Thereafter the source can be connected to the destination onl
9. ame and a specific confp PanelName Panel control panel template name to download that template to that PanelTemplate panel The echop Echo Panel command does the opposite connect Connect Used followed by ANC index input output and slice to connect the input and output referenced Allows a Take by specifying E EE Physical Matrix input and output numbers rather than source Slice P and destination names cp Control Panel Used as a modifier following the Is list command to list the pr cp PanelName number of panels used the current limit and control panel type and name Used as a modifier following the pr print command and followed by a specific control panel name to list control panel address and name deassign Deassign Used followed by a specific destination name followed by a deassign specific source name to remove the source from assignment to DstName SrcName that destination See Assign dev Device Used alone or as a modifier after Is list to list number of 1s dev devices maximum configured limit and device names dxs Destination Used alone or as a modifier following Is list to list destination pr dxs Exclusion Sets exclusion sets by number Used as a modifier following pr ExcSetName print and followed by a specific destination exclusion set name to list destinations in that set echop Echo Panel Used followed by a specific control panel name followed by a echop PanelName specific control panel template name to copy the
10. ard is a Global Serial Channel Mezzanine or asy means the Mezzanine board is an Asynchronous Mezzanine and file is the optional name of the executable file to download If the file name is left off a default file name is used or if parameters have been previously defined for the mezzanine the previously defined file name is used SMS7000 gt slot slot mez mez mezname gsc asy csos bin May also be used to remove parameter definitions for a mezzanine SMS7000 gt slot slot mez mez rm Where slot is the number of the CIF frame slot mez is the number of the Mezzanine board to be affected rm removes the definitions The Series 7000 Control Frame contains ten module slots numbered 1 through 10 The redundant pair of MCPUs reside in slots 9 and 10 the other eight slots are used for Communications Interface CIF modules Each odd even slot pair i e 1 amp 2 3 amp 4 5 amp 6 7 amp 8 are used to contain redundant pairs primary and secondary of CIF modules to provide fault tolerance Each CIF can support up to four mezzanine boards Global Serial Channel or Asynchronous Mezzanines of various communications functionality Both CIF modules in a pair must be configured with identical mezzanine hardware Mezzanines on a CIF module are numbered from 1 through 4 according to their physical position See the Installation Manual Each mezzanine when initialized corresponds to a network and is assigned a network address The mezzanine
11. ch will not affect system performance Diagnostic messages are posted to one of two message queues A High Priority queue and a Low Priority queue The High Priority messages are printed before other system task processing the Low Priority messages are printed after other system task processing Each message is given one of five severity levels Informational Warning Error Severe Fatal The Severity Level may be defined so that only errors of a certain severity or greater are printed to the terminal while errors of lesser significance are ignored The default system Severity Level is Error Exception During system initialization Severity Level is set to Info rmational and then assumes the defined level once the configuration file is read For example if Severity Level is set to Informational all error messages will be printed If Severity Level is set to Error only Error Severe Fatal and Other messages will be printed Organization Messages are generated by several different software tasks within the Series 7000 system The format of messages generated by different tasks do not necessarily match each other Messages documented in this section are organized according to message severity level if a message does not specify severity level it is grouped as other Organization is Informational Warning Error Severe Fatal Other General Message Format The general format of a message printed to the terminal is lt q
12. control panel TemplateName configuration to the specified template Configure Panel confp does the opposite kst Keypad Sets Used alone or as a modifier following Is list to list the number pr kst limit order or assignment and names of keypad sets Used as KpdSetName a modifier following pr print and followed by a specific keypad set name to list that keypad assignment set prot Protect Used as a modifier following pr print to display protects by prot DstName destination and level Used as a modifier preceding a specific LvlName s destination name followed by a specific level name to protect the specified destination Also see the unprot command rename Rename Used as a modifier preceding cp control panel or nc node randame cp controller followed by the specific old name followed by the OldName NewName specific new name to rename a device renamebya Rename by Used as a modifier preceding a device network address renamebyaddr ddr Address followed by a specific new name to rename that device Use Is 19 6 NewName dev list devices to obtain network and address Remove leading zeros from the network and address sre Source Used alone or as a modifier following Is list to list sources by pr src SrcName level Used as a modifier following pr print and followed by a specific source name to list a specific source and associated virtual matrices sst Suffix Sets Used as a modifier following Is list to list panel suf
13. dicated software if available Check to see if system configuration matches hardware If both configuration and hardware appear OK try resetting devices or reseating the boards associated with the problem NETEDEVADDRINUSE Device address conflict The system software found a value for a network that was already in use The system is in an unusual state Check too see if the system was unusually busy for some reason are devices getting deleted and added back are there lots s of takes 100 s You may want to try to switch to any redundant hardware to see if the problem occurs again If the problems continues reset the MCPU Check software and hardware revisions Reload indicated software if available Check to see if system configuration matches hardware Reload indicated software if available NETEINVLDSTATE Incorrect coprocessor state A coprocessor mezzanine did not change to the state is was told to go Check to see if the system was unusually busy for some reason are devices getting deleted and added back Are there lots of takes 100s You may want to try to switch to a redundant CIF to see if the problem occurs again If the problems continues reset the CIF Check software and hardware revisions Check system configuration matches hardware NETESTATECHNGTMO Coprocessor state change timeout A coprocessor tried to change it s state e g backup primary idle etc Check to see if the system was unusually busy for some reason are dev
14. dundancy type slot mezzanine position csg Client Server Used alone to list Client Server Panel groups Used as a list all Group modifier following Is list to list Client Server Panel groups by groups 1s csg number Used as a modifier following pr print and preceding ae KA TOA a Client Server Panel group name to list information about ELN g that group specifically diaglog Diagnostic Log pr diaglog Used as a modifier after the pr print command to list the Series 7000 Diagnostic Log diagnose Diagnose N A N A Command Meaning Usage SMS7000 gt dirtly Direct Tally Used alone to list names of Tally Modules with direct tally ls dirtly assignments Used as a modifier after Is list to list names and addresses of Tally Modules with direct tally assignments dmacount DMA Count Used as a modifier after clr to clear DMA counts which are clr dmacount listed in the system status SS display dmtx Data Matrix Used alone or as a modifier after Is list to list number limit pr dmtx MtxName names and order of assignment of Data Matrices Used as a modifier after pr print and followed by a specific data matrix name to list the forward and reverse levels drtst Dual Used for debugging the monitor board dual reference sensing drtst all Reference reset or no value stop test changes print changes note Test this is not implemented yet all print all once forceauto force auto mode off turns off code in NC dia
15. ecified task ls anc pr lvl LvlName ls mez ls mezconfig monitor DstName monitorcon PMName PMOutput netevent off on On Used as a modifier following bs Broadcast Status Task ds Destination Status Task log netevent Net Event Task poll Polling Task sc Spit Connect Task or spit Spit Task to activate the specified task netevent on pm pr Physical Matrices Print Used alone or as a modifier following Is list to list the number limit name configuration and assignment order of Physical Matrices Used as a modifier following pr print and followed by a specific physical matrix name to display a map of the active crosspoints for that matrix Used as a modifier preceding many item types anc active node controller cnc configured node controller etc to display information about that item type pr pm PMName pr cnc prog Program Used as a modifier preceding fileName deviceType and deviceSubtype if needed to program application code into the flash memory of certain devices Additional information see prog Command on page 5 10 prog FileName cp bps Pxg rdstassig n read Reboot room Programmable X Y Groups Read Destination Assignment Read Reboot Room Used to list PXY panel groups Used followed by a file name to read in destination assignments from a specified file Used as a modifier followed by a configuration file na
16. eck the network connections replace the mezzanine if indicated If this occurs on the IPCB inter processor comm bus network check the backup MCPU NETECANTGETBUF Unable to get message buffer Printed if the get buffer function detects and error when attempting to reserve a buffer for a coprocessor message Probably the result of a busy interface usually a temporary condition Take no action unless the error continuously occurs If it continues check the network connections replace the mezzanine if indicated NETECANTQUEMSG Unable to queue message Printed if the get buffer function detects an error when attempting to reserve a buffer for a coprocessor message Probably the result of a busy interface usually a temporary condition Take no action unless the error continuously occurs If it continues check the network connections replace the mezzanine if indicated Severe Messages NETMBF Can t get message buffer Printed if the get buffer function detects an error when attempting to reserve a buffer for a coprocessor message Probably the result of a busy network interface i e all buffers temporarily in use Take no action unless the error continuously occurs indicating a possibly faulty interface If the error continues check network connections replace the Mezzanine if indicated NETWRK lt var text gt net lt n gt for Control Message lt var text gt Printed from a common control message function which sends control
17. ed or system is affected reset and or rename Node Controllers If problem continues reset MCPU ANCHealthUpdate WARNING couldn t switch to backup Configuration memory or other system problem If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset and or rename Node Controllers If problem continues reset MCPU ANCHealthUpdate WARNING node control backup state mismatch Configuration memory or other system problem If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset and or rename Node Controllers If problem continues reset MCPU ANCHealthCheck WARNING no health response from NC lt name gt Configuration memory or other system problem Node controller off line If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset and or rename Node Controllers If problem continues reset MCPU ANCHealthCheck WARNING couldn t switch to backup Configuration memory or other system problem Node controller off line If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset and or rename Node Controllers If problem c
18. fix sets pr sst Used as a modifier following pr print and followed by a SfxSetName specific suffix set name to display that suffix set t Used as a modifier preceding a destination name followed bya t DstName source name and optionally a level name to take the SrcName Lv1lName specified source to the specified destination on the specified level If no level is specified the take will be of all levels associated with the source unprotove Unprotect Used as a modifier preceding a specific destination name unprotoverride rride Override followed by a level name to unprotect the specified destination DstName LvlName on the specified level overriding other factors Diagnostic Messages When the Series 7000 operating system detects an error it generates both a diagnostic code and a more verbose explanation of the error Error codes are abbreviated explanations of errors suitable for control panel display Codes are visible to the panel which caused them to be generated and to any other panel in active control of the same destination as the panel which caused the error Control panel error codes are defined in the Series 7000 User Manual Pertinent diagnostic explanations are sent by the Series 7000 MCPU to the terminal connected at the Diagnostic Interface Viewing Diagnostic Messages Diagnostic messages are displayed on the diagnostic terminal as they are sent by the system MCPU Most diagnostic messages reflect occurrences whi
19. gs sends values to registers 2 3 4 5 on monitor ex diags 2 3 4 5 dst Destinations Used alone to list names of all destinations Used as a modifier following Is list to list destinations by level name Used as a modifier following pr print to list destinations by virtual matrix pr dst a e ooo oo 22 2 a ee Le dstassign Destination Used alone or as a modifier following Is list to list destination pr dstassign Assignments assignments by number Used as a modifier following pr print dstname to list destination assignments in greater detail dststat Destination Used followed by a Destination name and optional specified dststat dstname Status level to print status of a Destination exception Exception Used as a modifier following Is list clr clear or set to list clr exception clear or set exception objects excl Exclusions Used alone or as a modifier following Is list to list exclusions pr excl DstName sources excluded from selection on particular destinations by number Used as a modifier following pr print and followed by a specific destination name to see exclusions for that destination ext External Used as a modifier following Is list to list active external ls ext Devices devices communicating over the 7000 buses automation systems other routers etc i 2 oo oni Used alone or as a modifier preceding an Active Node ae Controller index number to retrieve the version number of the Controller
20. gt lt s gt lt taskname gt lt module or exception name gt lt text gt Where lt gt indicates the message was printed from the Diagnostic Message Logging system lt q gt is L for Low Priority or H for High Priority lt s gt is I W E S or F to indicate Severity Level not always reported lt taskname gt is the name of the task from which the message was posted lt module gt is a prefix indicating the source code file which posted the message lt text gt is the specific message text For example SLE smsApp NETCFG Mezzanine type doesn t match configuration The example message was from the Low Priority queue and of Error Severity Level The posting task was smsApp the posting module was NETCFG The text indicates that the mezzanine board type read from coproc cfg did not match the mezzanine type that was read from hardware For example an Asynchronous Mezzanine configuration was sent to a Global Serial Channel Mezzanine board Setting Severity Limit for Error Reporting To view the current Severity Limit enter SMS7000 gt lm severity To set the Severity Limit which will be in effect after the configuration is read in enter SMS7000 gt 1m severity level Where level can be info informational warn warning error severe fatal off disables error reporting default system default is error Changing the Default Severity Limit To change the default Severity Limit enter SMS7000 gt lm save severity T
21. he current Severity Level will be saved as the system default used during system initialization To save the current Severity Level as the default message severity level used after initialization enter SMS7000 gt 1m save default Example Messages The following message examples can be printed from the Diagnostic Message Logging system The messages appear in the format as shown in General Message Format page 5 15 All Informational messages start with LI lt task name gt Warning messages start with LW lt task name gt etc Informational Messages NETMBF Can t free message buffer Printed if the get buffer function used by most system processes to reserve a message buffer detects an error when attempting to reserve a buffer for a coprocessor message Probably the result of a busy network interface i e all buffers temporarily in use Take no action unless the error continuously occurs indicating a possibly faulty interface If the error continues check network connections replace the Mezzanine if indicated NETALR Network alarm received A significant event occurred for a network e g a network was deleted a switchover occurred etc Check the hardware associated with the network try resetting devices or reseating boards causing the problem If problem persists attempt a switchover to a redundant board if available Final action if necessary is an MCPU system reset NETALR Alarm server socket queue rece
22. hutdown and start up sequences This same function waits for a response from the coprocessor and if the response state from the coprocessor does not match the expected state this message is printed Could be a busy coprocessor Take no action unless the message repeatedly occurs In which case it is probably the result of a failed coprocessor Replace the failed Mezzanine REDEMCPUKILLSELF This MCPU is killing itself This message appears when the MCPU is rebooted or switchmcpu is done No action is needed REDE2PRIMRYMCPU Found 2 primary MCPUs The primary MCPU found the state of the backup to be primary as well Take no action unless condition persists Remove or restart backup NETECANTINSDRYV Unable to install driver Driver could not be found by network Call Customer Service SMSECANTFIND Fatal error while searching for item Hardware or software is not running properly Attempt a switchover to redundant module if available Otherwise reset MCPU Call Customer Service SMSECANTINIMOD Fatal error while initializing module Hardware or software is not running properly Attempt a switchover to redundant module if available Otherwise reset MCPU Call Customer Service SMSECANTSPNTSK Fatal error while spawning a task System software is not running properly Attempt a switchover if redundant MCPU is available Otherwise reset MCPU Call Customer Service SMSECANTCREQUE Fatal error while creating message queue System sof
23. ices getting deleted and added back Are there lots of takes 100s You may want to try to switch to a redundant CIF to see if the problem occurs again If the problems continues reset the CIF Check software and hardware revisions Check system configuration matches hardware NETECANTSHUTNET Unable to shutdown network The system is in an unusual state Check to see if the system was unusually busy for some reason are devices getting deleted and added back Are there lots of takes 100s You may want to try to switch to a redundant CIF to see if the problem occurs again If the problems continues reset the CIF Check software and hardware revisions Check to see if system configuration matches hardware NETECANTRECVMSG Unable to receive message Printed if the receive buffer function detects an error when attempting to reserve a buffer for a coprocessor message Probably the result of a busy interface usually a temporary condition Take no action unless the error continuously occurs If it continues check the network connections replace the mezzanine if indicated If this occurs on the IPCB inter processor comm bus network check the backup MCPU NETECANTSENDMSG Unable to send message Printed if the get buffer function detects an error when attempting to reserve a buffer for a coprocessor message Probably the result of a busy interface usually a temporary condition Take no action unless the error continuously occurs If it continues ch
24. ive error The text portion of this message is a program error Call Customer Service NETEOK Success Successful result Warning Messages REDEMCPUMODECHNG MCPU opMode has changed The backup MCPU has changed to another state i e backup primary synchronized etc Take no action unless message repeats continually Replace backup MCPU if indicated NETEMEZFOUND System found mezzanine MCPU has restored communication with a mezzanine No action required NETEIOBLOCKED I O blocked The system could not send a message to get network events if any This is more a warning that the system may be busy Take no action unless the problem continues if it does try to determine any unusual activity in the system that might cause many messages to be sent Try to reduce this system activity The most likely cause is a disconnected communication cable or a device is not working which is connected to an AMEZI board NETETALLYNAME Tally network configured wrong The Tally system does not match the configuration Check the configuration to make sure it matches the hardware associated with the network If both configuration and hardware appear OK try resetting devices or reseating the boards associated with the problem The most likely cause is a tally mezzanine is configured as a standard GSC mezzanine Error Messages CSTESENDCFGTMO system configuration send timed out The system tried to send configuration data to backup MCPU and could no
25. me to read the configuration file in Flash memory of the currently active MCPU into the RAM memory of that same MCPU The system operates using the configuration in RAM Also see the wecommand This command will completely erase the existing configuration in RAM Be sure this is the intent before exercising this command Reboots the Series 7000 Control System Used alone System will reboot This command will reboot your Series 7000 Control System Be sure this is the intent before exercising this command Used alone or as a modifier following Is list to list rooms Used as a modifier following pr print and followed by a specific room name to list information about that room ls pxg rdstassign filename read c cl Reboot pr room RoomName roomassig n rte Room Assign Real Time Clock Used as a modifier following pr print and followed by a specific room name to list room assignments Used alone to display current real time clock information pr roomassign RoomName rtc Status Used as a modifier preceding a specific destination name to display source assigned to that destination status and protect chop downstream and downstream chop status s DestName Command Meaning Usage SMS7000 gt slot Slot Used as a modifier followed by a slot number 1 10 to slot Slot determine what mezzanine cards are present on the CIF switch module in that slot Used a
26. messages to a coprocessor during the shutdown and start up sequences if a message buffer has not been reserved or if the expected change state response was not received from the target coprocessor The lt var text gt depends upon failure and message type This could be a busy coprocessor Take no action unless the message repeatedly occurs in which case it is probably the result of a failed coprocessor Replace the failed Mezzanine NETWCH Unknown message type from network May have release mismatch Check release revision numbers for software using ver all command Also check hardware revisions if any If message occurs repeatedly attempt to reset the device causing the error message NETWCH Event status from invalid network An unusual state for the system has occurred hardware or software problem If message occurs repeatedly attempt to reset the device causing the error message NETWCH Event status from network unknown network type An unusual state for the system has occurred hardware or software problem If message occurs repeatedly attempt to reset the device causing the error message CBDEUNKNOWNNETERR Unknown network error System software received a network initialization error it could not interpret Check the hardware associated with the network If the hardware appears OK try resetting devices or reseating the boards associated with the problem Check release versions of hardware and software CBDEUNKNOWNNETTYPE U
27. name assigned through the GUI is also assigned to the network The network the devices with which the Mezzanine communicates and the mezzanine itself uses the same name as that assigned to the mezzanine for purposes of easy identification in system commands and messages st Command In addition to the information in Table 5 1 on page 5 6 the following applies to the st command Where mm month of year 01 through 12 dd day of month 01 through 31 yyyy digits of year hh hour of day 24 hour clock 01 through 24 valid mm minutes past hour 01 through 59 ss seconds past minute 01 through 59 ver Command In addition to the information in Table 5 1 on page 5 6 the following applies to the ver command sms primary MCPU application net active networks cp control panels cpos control panel operating system EEPROM nbx node controller operating system EEPROM nc node controller application If a specific item i e control panel name is used following one of the above the software version for only that specific item will be reported Diagnostic Terminal GUI Commands Table 5 2 contains Diagnostic Commands that are usually handled by using the GUI The only time that these commands should be used is if the GUI cannot connect to the router Table 5 2 Diagnostic Terminal GUI Commands Command Meaning Usage SMS7000 gt confp Configure Used followed by a specific control panel n
28. nknown network type for mezzanine The mezzanine and configuration do not match each other The hardware is likely at fault The mezzanine hardware type code is not recognized Also check the configuration make sure it matches the hardware associated with the network If both configuration and hardware appear OK try resetting devices or reseating the boards associated with the problem CBDETOOMANYNETWORKS Too many networks created Message occurs if too many networks are detected Check the system configuration limits Re send the configuration Check cabling isolate network if problem continues switch to redundant hardware if present SMSEBADPROGPATH Error in program path The specified path to a file was not correct or the file does not exist in the path Call Customer Service Fatal Messages NETWCH Heartbeat timeout on network lt n gt Printed if a coprocessor mezzanine hardware fails to increment its heartbeat time counter in a timely manner The coprocessor is expected to increment the timer a minimum of once per second The coprocessor mezzanine network will shut down if this error occurs If redundant CIF and mezzanine backups are available the system will switch to them automatically Replace the faulty Mezzanine board NETWRK Network state lt state gt net lt n gt not correct for Control Message lt state gt Printed from a common control message function which sends control messages to a coprocessor during the s
29. ontinues reset MCPU Error cncinfo prec null Configuration memory or other system problem Node controller off line If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset and or rename Node Controllers If problem continues reset MCPU mtPrintPMs ERROR bogus pmindex lt physical matrix index gt Configuration memory or other system problem Node controller off line If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset and or rename Node Controllers If problem continues reset MCPU Event Logging If the function is enabled the Diagnostic Interface terminal will maintain an event log The event log is a First In First Out buffer that can hold up to 255 event messages The log is user configurable to record events ranging from the addition of a device to Takes Protects alarms and more Enabling or Disabling Event Logging To enable the event log can be overridden by log set commands below SMS7000 gt log on To set event logging to be automatically enabled after a reset or restart SMS7000 gt log set on To set event logging so that it must be manually enabled after a reset or restart SMS7000 gt log set off To shut off the event logging task can be overridden by log set commands SMS7000 gt log off
30. or as a modifier following Is list to list Tieline ls tltype tlydst Tally Used alone or as a modifier following Is list to list tally pr tlydst Destinations destinations Used as a modifier following pr print and DstName followed by a specific tally destination name to list information about only that destination tlymod Tally Module Used alone or as a modifier following Is list to list Tally pr tlymod Modules Used as a modifier following pr print and followed TallyModName by a specific tally module name to list information about only that tally module tlysre Tally Source Used alone or as a modifier following Is list to list tally pr tlysre sources Used as a modifier following pr print followed by a SrcName specific tally source name to list information about only that tally source tms Timed Salvos Used alone or as a modifier following Is list to list Timed pr tms Salvos Used as a modifier following pr print and followed by TSalvoName a specific timed salvo name to list information about only that timed salvo tpl Template Used alone or as a modifier following Is list to list control panel pr tpl templates Used as a modifier following pr print and followed TemplateName by a specific template name to list information about only that template ver Version Used alone to display MCPU application version Used as a ver cp modifier preceding allto display all reportable software versions Used as a modifier preceding one of
31. s a modifier followed by a slot number 1 10 and switch to initiate a manual switchover of primary and redundant CIF modules in the slot pair Additional information see slot Command on page 5 11 st Set Used alone to examine system date and time Used as a st 11 24 1994 08 modifier preceding date and time to set system date andtime 56 37 Date Time format mm dd yyyy hh mm ss Additional information see st Command on page 5 12 svo Salvo Used as a modifier following Is list to list salvos Used as a pr svo modifier following pr print and followed by a specific salvo SalvoName name to list information about that salvo SVps Salvo Used to list Is all salvo permission sets by number or display 1 Permission all permitted salvos in a specified set by typing pr po SYPS OT PE 75 A vps Setname Sets svpsfollowed by the specific set name in quotes switch Switch Used as a modifier following pg slot to switch active CIF ina PS 1 switch redundant pair of CIFs switchanc Switch Active Used as a modifier preceding a configured node controller 3 Node name to copy the configured node controller data into the rake rear ee ncName Controller specified active node controller switchmep Switch Active Used alone to switch control from one MCPU to the other in a switchmepu u MCPU Fault Resistant Unit pair primary and backup MCPUs tl Tie Lines Used alone or as a modifier following Is list to list Tielines ls tl or ls inuse tl tltype TieLine Type et
32. several topics to display the software version of that particular item For additional information see ver Command on page 5 12 Used alone or as a modifier following Is list to list Virtual vm Virtual Matrix Matri ls vm atrices we Write Used as a modifier preceding a file name to copy the we c cl Configuration configuration in RAM on the active MCPU to Flash memory on that same MCPU The file name c clshould be used Additional information see wc Command on page 5 10 waatuseis Write Used followed by a file name to write destination assignments wdstassign o Destination to a specified file filename Assignment Additional Command Information wc Command In addition to the information in Table 5 1 on page 5 6 the following applies to the wc command The configuration MCPU Flash system file name c cl is used when the MCPU is cold started The file c cl no other file name will work is copied from Flash memory to RAM when cold started before the file is executed Only the configuration file loaded into RAM is used for active system operation The Flash file system can contain other configurations named differently from c cl but only c cl will be copied in the event of a cold start The read command can be used to copy these other files to RAM if you wish to use them If there are multiple files in Flash it is possible to use up Flash memory and have inadequate room remaining when attempting to store a new configuration If so
33. software if available Check to see if system configuration matches hardware NETEUNKNWNNET Invalid network The system software found a bad value for a network address The system is in an unusual state Check too see if the system was unusually busy for some reason are devices getting deleted and added back are there lots s of takes 100 s You may want to try to switch to any redundant hardware to see if the problem occurs again If the problems continues reset the MCPU Check software and hardware revisions Reload indicated software if available Check to see if system configuration matches hardware NETEUNKNWNSOC Bad socket number A device sent a message that the MCPU could not interpret Could be a bad device cable or software release mismatch Check the device that created the problem Check cables and hardware associated with the device that created the problem Check software and hardware revisions Reload indicated software if available Check system configuration matches hardware If both configuration and hardware appear OK try resetting devices or reseating the boards associated with the problem NETERCVBADSOCMSG Received bad socket message A device sent a message that the MCPU could not interpret Could be a bad device cable or software release mismatch Check the device that created the problem Check cables and hardware associated with the device that created the problem Check software and hardware revisions Reload in
34. system is affected reset MCPU ResetANCmsgWindowFrAddr WARNING can t reset window Extremely busy communications bus Node Controllers going on and offline If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset MCPU SyncANCmsgWindowFrAddr WARNING can t sync window Extremely busy communications bus Node Controllers going on and offline If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset MCPU CreditANCmsgWindow WARNING can t credit window Extremely busy communications bus Node Controllers going on and offline If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset MCPU ANCHealthUpdate WARNING no device record Configuration memory or other system problem If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generated or system is affected reset and or rename Node Controllers If problem continues reset MCPU ANCHealthUpdate WARNING no node control record Configuration memory or other system problem If message is only occasional and system does not appear to be affected negatively ignore it If message is continuously generat
35. t Command Log Out Meaning If using TelNet from a PC or workstation use logout to log out of the Diagnostic Interface Usage logout SMS7000 gt 1s lvl mez mezconfig monitor monitorco n off List Level Mezzanine Mezzanine Configuration Monitor Monitor Connection Off Used preceding many topics to list pertinent information Enter h Is for a list of topics which work with the list command Used alone or as a modifier following Is list to list levels and associated virtual matrices Used as a modifier following pr print and followed by a specific level name to view information about that level Used as a modifier following Is list to list mezzanine board slot location ID and type Used as a modifier following Is list to list mezzanine board slot location ID type and configuration information Used preceding a destination name to take it to the monitor output A control panel configured to control the monitor crosspoints should be used for this function Used followed by a Physical Matrix name followed by a Physical Matrix output number to take it to the monitor output A control panel configured to control the monitor crosspoints should be used for this function Used as a modifier following bs Broadcast Status Task ds Destination Status Task log netevent Net Event Task poll Polling Task sc Spit Connect Task or spit Spit Task to deactivate the sp
36. t do it for some reason Check the backup MCPU and the hardware associated with it If the hardware appears OK try resetting devices or reseating the boards associated with the problem CSTECANTSENDCFG can t send system configuration The system tried to send configuration data to backup MCPU and could not do it for some reason Check the backup MCPU and the hardware associated with it If the hardware appears OK try resetting devices or reseating the boards associated with the problem CSTECANTRECVCFG can t receive system configuration Backup MCPU was unsuccessful in receiving the configuration Check the hardware associated with the backup MCPU If the hardware appears OK try resetting devices or reseating the boards associated with the problem CBDEMEZTYPMISMTCH Mezzanine type mismatch with configuration System is coproc configuration doe not match hardware Check the system configuration Check the configuration make sure it matches the hardware associated with the mezzanine If both configuration and hardware appear OK try resetting devices or reseating the boards associated with the problem CBDENOHEARTBEAT Mezzanine heartbeat failed Heartbeat counter in the mezzanine has failed to increment Attempt switchover to redundant hardware if present replace mezzanine if indicated If switchover fails reset CIF REDEUNKNOWNRMCPUST Unknown remote MCPU state System is confused about state of redundant MCPU Restart backup MCPU
37. tware is not running properly Attempt a switchover if redundant MCPU is available Otherwise reset MCPU Call Customer Service SMSECANTCREQUE Fatal error while creating message queue System software is not running properly Attempt a switchover if redundant MCPU is available Otherwise reset MCPU Call Customer Service SMSECANTCRESEM Fatal error while creating semaphore System software is not running properly Attempt a switchover if redundant MCPU is available Otherwise reset MCPU Call Customer Service Other Messages NETCFG Syntax error after slot number Something other than mez switch or end of line was detected after the slot or pg command Printed from the coproc cfg file while parsing the slot or pg command This file contains the Communications Interface CIF and Mezzanine board parameters Re enter the command or query which produced the error InitANCConfig ERROR creating semaphores Configuration memory or other system problem Reset Node Controller Reset MCPU InitNCConfigServer ERROR Couldn t create message queue Configuration memory or other system problem Reset Node Controller Reset MCPU AttachANC s ERROR CNC lt name gt already in use Configuration error Node Controller name already in use List Node Controller names Active and Configured Use a different name for a new Node Controller AttachCNC ANC lt name gt already in use Configuration error Node Controller name already in use
38. y if it is on the assignment list Assignment can be used as a condition of tally if so flagged when configuring the Tally System using the GUI btn Button Used as a modifier following the pr print command and pr btn followed by a specific control panel template name to display TemplateName the Keypad Set name specific prefixes assigned to buttons display arrangement matches panel button arrangement Suffix Set and specific suffixes assigned camezi Configured Used alone to get a count of Amezis configured Amezi limit ls camezi Amezis Used as a modifier following Is list to view Amezi configurations chopint Chop Interval Used alone to examine the current chop interval see the chopint 10 chop description preceding or followed by a numeric modifier from 0 through 16 specifying the interval in seconds An interval of 0 zero would disable the chopping function clrtlfeed Pe Used to clear tielines used by a destination clrtife dtodst todst g y a dstname destination clearallp Clear All Used alone to clear all protects in the system clearallprotects rotects Protects cnc Configured Used by itself or preceded by Is list displays the configured 1s cnc Node node controllers used the limit the number and name of Controller each and reference channel and status information coproc Coprocessor Used to show the coprocessors in the system Is coproc ls coproc provides the coprocessors and their configuration information I F type re