Home

Lucent Operatory Ceiling mount Dental Light

image

Contents

1. 6037 Retainer Ring Small 18 56038 Spring 19 56039 Screw Cap Head Socket 20 56040 Screw End Cap 21 56041 Friction Screw n Cleaning and disinfecting guide Table 1 The Manufacturer makes no representation as to the disinfectant efficacy of these products We make no warranty expressed or implied that these disinfectants will not damage the surface finishes Damage and discoloration of the surface finishes are not covered under the warranty lodophor based disinfectants will cause yellow staining on many surfaces Regular washing with soap and water will minimize this staining lodophor neutralizers such as Promedyne are also available Unacceptable Disinfectants These disinfectants will harm the surface finishes of dental equipment and are not recommended Use of these products will void your warranty Chemical Composition Trade Names Strong Phenols Lysol Lysol 2 Lysol Phenol Alcohol Professional Coe Foam Coe combinations Spray Pump Vitaphene Omni I Sodium Hypochlorite Clorox Ajax Purex Household Bleach Alcohol Household Cleaners Conditionally Acceptable Disinfectants These disinfectants have been found to be the least harmful to the equipment surfaces by our test methods Chemical Composition Trade Names lodophors Biocide Aseptic IDC Wescodyne SD5 Promedyne lodo Five Mild Phenols Procide ES Asepti Steryl Aerosol Glutaraldehyde Sterall Spray Coldspor Phenol Spray
2. TPC Lucent Operatory Ceiling mount Dental Light lt P Operation and service manual TPC 851 S Lawson St City Of Industry CA 91748 P626 810 4337 Fax 626 810 4245 www tpedental com REV 1 1 13 TPC Table on Contents Page GENERAL INFORMATION 3 Installation 4 Overview of components 5 Operation instructions 6 Light head and vertical arm adjustment aD replacement of light bulb 8 Replacement Parts List 9 CLEANING amp DISINFECTING GUIDE 12 Warranty 13 TROUBLE SHOOTING GUIDE 14 Technical Assistance is available Monday through Friday 8 00 Am to 5 00 PM PST General Information Definitions of symbols Risk of electrical shock present Make sure power is disconnected before attempting this procedure Type B equipment against electrical shock Protected a Caution Failure to carefully follow the described procedure may result in damage to the equipment or operator Dangerous Voltage AC Alternating Current off OO Pie Protective earth Ground e Model L800 Lucent Dental Light Serial No L800 8675309 Input Veltage 120V 60Hz Current LA Warning RISK OF FIRE CLASS 1 Replace fuse as marked 1A Fuses Manufactured 7 2009 18525 E Gale Ave City Of Industry CA 91748 6 13 32 REF 4 9 32 REF 716 MOUNTING HOLES Operatory Light Installation Secure mounting plate to the ceiling using supplied LAG bolts Ro
3. h or low function works econdary windings on transformers are expired Replace transformer Light turns on and off then the light head is moved Mair power swit Short or open in power line form transformer Light head tension springs are Replace main pov itch Check each power line for short or open Then replace Light head drifts down loose Vertical arm tension spring Tighten light head spring nuts Vertical arm drifts up or down needs to be adjusted Light post is not level Adjust vertical arm tension Light drifts from left to right Level light post 14
4. he light handle to move the vertical arm Once the light is in the desired location I will stay in that positions until you move it back Light Head adjustment x If you experience a downward drift with your operatory light head please follow the following procedure below Remove the nut cover shown in the image below Tighten both retaining nuts on side of the light head See images below To tighten the nuts turn them clockwise Do not over tighten the nuts as damage may occur Tension Nut p Vertical Arm adjustment x If you experience a downward drift with your operatory lights vertical arm please follow the producer below Remove the end cap cover on the end of the vertical arm closest to the light head This requires a small Phillips screw driver Turn the nut located at the end of the light arm to adjust the tension Turn the nut clockwise to increase the tension Turn the nut counter clockwise to decrease the tension If your vertical light arm drifts down then you need to increase the tension If the vertical light arm drifts back up you need to decrease the tension Light Bulb Replacement Instructions 1 Locate the rear caver to the operatory light and remove the 4 Allen screws with a 3 32 Allen wrench 2 Locate the tension spring retainer Once you locate it press it in and rotate it counter clockwise These will UN lock the retaining spring that holds in the l
5. ight bulb 3 Remove the wire that connects the light bulb to the wiring harness the red wire Replace the light bulb with replacement light bulb part number P709 or similar Halogen lamp 12 Volts 55 Watts Replacement Parts List 2 gt we Si ttem_______Part____oo _______Number Description 1 56051 Yoke 2 56052 Support Yoke 3 56053 Handle Frame 4 56054 Socket Bushing 5 56055 Reflector 6 56056 Shield 7 56057 Rear Cover 8 56058 Tension Covers 9 56059 Light Bulb Tension Spring 10 P709 Light Bulb 11 56061 Light bulb Socket 12 56062 Reflector Holder Bushing 13 56063 Washer 14 56064 Rubber Grommet 15 56065 Large Washer 16 56066 Round Nut 17 56067 Deflector 18 56068 Cover Switch 19 56069 Power Switch 20 56070 Sensor PCB 21 56071 Screw 22 56072 Light Head Wire Harness 56003 56006 56007 56008 56009 56010 Light Bushing Rigid Arm Cover Transformer Transformer PCB Board Fuse Switch Screw X 4 Transformer Gover Screw Set Screw 10 F 12 20 m am a gt as ig a ie D E 16 1 56021 Cover Flex Arm 2 56022 Knuckle Rigid Arm 3 56023 Knuckle Head 4 56024 Spring Rod 5 56025 Extension Support 6 56026 Bushing 7 56027 Bezel 8 56028 Bushing 9 56029 Block Spring Tensioner 10 56030 Friction Block 1 56031 Tensioner Rod 12 56032 End Cap Cover 13 56033 Retainer Ring 14 56034 Long Pin 15 56035 Retainer Ring Small 16 56036 Short Pin 17 5
6. s Synergized Super Dis cide Cavicide Kleenaseptic Quat Phenol Water Sprays Top Cide Sporicidin Pump Spray Birex se 2 Warranty Information All of our products sold are guaranteed to be free trom detects in workmanship and materials for a 1 year from date of purchase unless otherwise stated TPC will repair or replace any defective part at no charge TPC will nat be responsible for labor charges or shipping charges to from the TPC facility This guarantee does not cover normal wear or stains on surface finish The guarantee does not cover damage resulting from improper installation misuse or accidents incurred in shipping and handling All claims against the freight carrier must be initiated at the time the damaged items are received The claim is the responsiblity of the customer We are improving our products on a continuous basis We reserve the right to make modifications without the need for prior notification and are not obliged to modify previously manufactured items Light bulbs are not covered under any type of warranty Only authorized service technicians should attempt to service TPC equipment Service performed by any unauthorized technician may result in a voided warranty 3 Troubleshooting Guide Problem Cause Solution Light does not illu No power to light Check power Light bulb has expired Replace light bulb Transformer is expired Replace transformer Only hig
7. ute power supply through the center of the mounting plate Install the leveling nuts between the mounting plate and ceiling flange if not already attached Route the wire through drop post and Install the light post into the ceiling flange and secure it with the provided roll pin Secure the light post to the ceiling flange by tightening the set screws Slide the flange cover and flange cover retaining ring up over the drop post and secure it in place Connect the incoming power lines to the 3 cord wire and secure it with wire nuts Install the light transformer housing to the drop post and attached it using only the supplied set Beer snam crews See diagram below for plate and flange installation Level Adjusting Nut MOUNTING PLATE Washer Nut LAG BOLT USE FOR LEVELING Operating Instructions X Move power switch to the left to set the light to high intensity Move the power switch back to the center position to turn it to the off position Mave the power switch to the right to right to turn it to low intensity X To adjust the position of the light place your hand on the light handle and move it to the desired location You can move the light head up and down and left and right When turning the light head left and right it will stop don t force any further movement of the light head as damage may occur x To bring the light closer to the patient or desired illuminated location pull down on t

Download Pdf Manuals

image

Related Search

Related Contents

testo 330 V3 (0632 3306, 0632 3307) · Analizzatore  Vogel's PFW 6830 flat panel wall mount  Jammin Pro Mic001  VAX 6000 Platform Service Manual  ポイラ一及び圧力容器の地震後の復帰指置につしゝて  OM, 122 HD45, 122 HD60, 2013-02, EN, FR, ES    分光センサ Amadeus SE-7183  91 Dodge Truck Diesel SM Supp  22-11-2010 Comunicado nº 19 - Manual de  

Copyright © All rights reserved.
Failed to retrieve file