1. The RPS9 can be operated as a free standing unit without requiring any special cooling arrangement but should not be accidentally or deliberately covered in any way Always stand the unit on a firm flat surface well away from any soft furnishings such as carpets or curtains Rack Mounting The RPS9 is designed as a 19 inch rack mount unit and will occupy 2U 3 5 inches of rack space An important consideration when rack mounting the unit is the need for natural convection of air flow over the whole unit Good ventilation below the unit in the floor or back of the rack will ensure a path for continuous air flow Other equipment in the rack which is known not to produce a significant amount of heat should be mounted below the unit Equipment which also relies on good air flow within the rack i e most power amplifiers and other power supplies should be given due consideration and some space should be provided between such units and between the RPS9 unit Forced convection by means of a fan tray may be desirable in this situation Location As with any power supply that contains a mains voltage transformer it is recommended that the RPS9 is physically separated from other equipment particularly that which carries low level audio signals to avoid any possible hum pick up For this reason the unit is provided with a long 3m output cable to enable it to be positioned away from the mixing console For the same reason when rack mounting it is
2. USER GUIDE PUBLICATION AP0334 LIMITED ONE YEAR WARRANTY This product has been manufactured in the UK by ALLEN amp HEATH and is warranted to be free from defects in materials or workmanship for a period of one year from the date of purchase by the original owner To ensure the high level of performance and reliability for which this equipment has been designed and manufactured please read the User Guide before use In the event of a failure notify and return the defective unit to ALLEN amp HEATH or its authorised agent as soon as possible for repair under warranty subject to the following conditions CONDITIONS OF WARRANTY 1 The product has been installed and operated in accordance with the instructions in the installation instructions in the User Guide 2 The product has not been subject to misuse either intended or accidental neglect or alteration other than as described in the installation instructions in the User Guide or approved by ALLEN amp HEATH 3 Any necessary adjustment alteration or repair has been made by ALLEN amp HEATH or it s authorised agent 4 The defective unit is to be returned carriage prepaid to ALLEN amp HEATH or it s authorised agent with proof of purchase 5 Units to be returned should be packed to avoid transit damage These terms of warranty apply to UK sales In other territories the terms may vary according to legal requirements Allen amp Heath Agent ALLEN amp HEATH Kernick
3. SHOULD BE UNDERTAKEN ONLY AFTER DISCONNECTING THE MAINS SUPPLY LEAD FROM THE POWER SUPPLY UNIT The RPS9 power supply unit requires no internal maintenance or regular servicing If the RPS9 requires servicing or repair then refer to the service manual for the power supply or contact your Allen amp Heath dealer
4. at the output of the power supply unit RPSY O ABWERSUPPLY RPS9 power supplv to mains electricitv T IMPORTANT Please read this manual carefully before connecting your This product complies with the European Electromagnetic Compatibility directives 89 336 EEC amp 92 31 EEC and the European Low Voltage directive 73 23 EEC amp 93 68 EEC Warning to the User Installer Service Engineer Allen amp Heath warns that any unauthorised changes or modifications to the RPS9 unit may invalidate the legal compliance of the unit and could void the user s authority to operate the equipment Precautions and Safety instructions General Precautions Avoid storing or using the RPS9 in conditions of excessive heat or cold or in positions where it is likely to be subjected to vibration dust or moisture Do not use any liquids to clean the exterior of the unit A soft dry cloth or brush is ideal SOLVENTS MAY CAUSE DAMAGE TO PAINT OR PLASTIC PARTS Handling and Transport The RPS9 is supplied in a specially designed cardboard box If it is necessary to move the unit any distance after installation it is recommended that this carton is used to protect it Be sure to disconnect all cabling before moving If the RPS9 is to be moved regularly e g touring it is recommended that it is installed in a foam lined case At all times avoid applying excessive force to any switches or connectors Installation of the RPS9 Free Standing
5. preferable to avoid locating the unit adjacent to signal processing equipment Earthing Finally some consideration should be given to the earthing arrangement of the system at the centre of which is the console and the RPS9 The console chassis is earthed to mains earth via the power supply When rack mounting the RPS9 care should be taken to avoid any possible ground loops in the system which would introduce audible hum to otherwise clean audio signals Ground loops may occur where signal processing equipment patched to the console has its signal earth connected to the equipment chassis A ground loop is formed if the chassis of the signal processing equipment and the RPS9 chassis are in electrical contact through the fixing rails they share in the rack The RPS9 includes a ground lift switch on the rear panel This isolates the audio OV from the chassis earth Operation of this switch may alleviate hum caused by a ground loop Note that this will not disconnect the console chassis from mains earth which must remain connected at all times Using the RPS9 ALWAYS MAKE SURE THAT THE POWER SUPPLY HAS BEEN SET TO THE SAME AC MAINS VOLTAGE AS PROVIDED FROM THE MAINS SOCKET OUTLET Always switch the power supply off before connecting or disconnecting the console power cable removing or installing modules and servicing In the event of an electrical storm or large mains voltage fluctuations immediately switch off the power supply and d
6. Industrial Estate Penryn Cornwall England TR10 9LU www allen heath com Tel 01326 372070 Fax 01326 377097 H A division of Harman International Industries Ltd copyright 1999 ALLEN amp HEATH All rights reserved Publication AP0334 Issue 3 IMcB 9 8 99 Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor ALLEN amp HEATH shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual No part of this manual may be reproduced stored in a retrieval system or transmitted in any form or by means electronic electrical mechanical optical chemical including photocopying and recording for any purpose without the express written permission of ALLEN amp HEATH It is recommended that all maintenance and service on the product should be carried out by ALLEN amp HEATH or its authorised agents ALLEN amp HEATH cannot accept any liability whatsoever for any loss or damage caused by service maintenance or repair by unauthorised personnel RPS9 Power Supply INTRODUCING THE RPS9 The RPS9 is a linear power supply which like other linear supplies produces DC voltages by rectifying smoothing and regulating AC voltages from the secondary windings of a mains transformer Allen amp Heath mixing consoles employ a number of DC voltage supply levels in their operation and these are provided
7. LTS 2 5A Max 16 VOLTS 2 5A Max 48 VOLTS 100mA Max DC Output Socket Pin Connections Pinl 16 Volts Pin2 AUDIO 0V Pin3 CHASSIS 0V Pin4 16 Volts Pin5 48 Volts Overall Dimensions Front Panel Chassis Maximum External 19 inch 2U 482mm x 88mm Height 78mm including feet 3 07 inches Width 400mm _ 15 75 inches Depth 130mm _ 5 12 inches Weight 5Kg 11 pounds Servicing THIS UNIT CONTAINS NO USER SERVICEABLE PARTS REFER ALL SERVICING TO A QUALIFIED SERVICE ENGINEER THROUGH THE APPROPRIATE ALLEN amp HEATH DEALER Initial operational tests on the power supply can be carried out by switching the unit ON and checking the front panel LED indicator is illuminated If the LED indicator is not illuminated check the fuses are intact in the mains plug where fitted and the unit fuseholder on the rear panel THIS OPERATION SHOULD ONLY BE CARRIED OUT BY A TECHNICALL Y COMPETENT PERSONNEL If the front panel LED indicator is illuminated but the console appears not to have any power then it may be necessary to check the voltages present on the output connector Refer to the Technical Specification section in this manual for the DC output voltage levels Any fault condition with the exception of simple fuse failures will require access to the internal assemblies of the power supply Servicing Components ALL SERVICE AND REPAIR WORK MUST ONLY BE CARRIED BY TECHNICALLY COMPETENT PERSONNEL REPLACEMENT OF ANY COMPONENTS
8. isconnect from the mains supply During normal operation some heat is generated This is dissipated by the rear heatsink and chassis ventilation DO NOT COVER THE UNIT DURING OPERATION THIS UNIT CONTAINS NO USER SERVICEABLE PARTS REFER ALL SERVICING TO A QUALIFIED ENGINEER THROUGH THE APPROPRIATE DEALER NETWORK Mains Voltage Setting SPECIAL ATTENTION SHOULD BE GIVEN TO THE FOLLOWING INFORMATION The RPS9 is capable of operating over a wide range of AC mains input voltages by means of a mains voltage selector It is important to check that the RPS9 has the correct voltage setting as marked on the rear panel of the power supply Confirm that the voltage setting matches the local AC mains supply in your area DO NOT CHANGE THE AC MAINS VOLTAGE SETTING WITHOUT FIRST DISCONNECTING THE MAINS LEAD FROM THE AC MAINS SOCKET To alter the setting of the AC mains WAC MAINS IN input voltage lever out the fuseholder with a suitable tool Pull the fuse carrier assembly clear of the unit and rotate it Check the arrow indicates the correct AC mains until the required voltage aligns with the arrow Push the fuse carrier back into place Check the correct fuse is fitted for the selected mains input voltage voltage setting for your local AC mains supply Set the voltage selector to 100 V for ac mains input voltages between 100 115 V ac 120 V for ac mains input voltages between 115 125 V ac 220 V for ac mains inp
9. ut voltages between 210 230 V ac 230 V for ac mains input voltages between 230 264 V ac DO NOT ATTEMPT TO USE THE POWER SUPPLY IF IT IS SET TO A DIFFERENT AC MAINS INPUT VOLTAGE TO THE LOCAL AC MAINS SUPPLY IN YOUR AREA DO NOT USE DC MAINS INPUT VOLTAGES The power supply is provided with an IEC type mains connector and a moulded mains plug Check that this is suitable for connection to the wall socket outlet Replacing Mains Fuse The AC mains fuse is located on the rear of the RPS9 unit next to the AC mains connector In the event of a mains surge or under rated fuse value the mains input fuse will rupture Switch off the power supply and remove the mains lead plug from the AC MAINS IN socket on the rear of the unit Check the fuse and replace if necessary Check also the AC mains input voltage setting is correct for the mains supply in your area before switching the unit on again TO AVOID THE RISK OF FIRE REPLACE FUSE WITH THE CORRECT TYPE ONLY AS INDICATED ON THE UNIT In the event of repeated failure of the mains fuse consult the local dealer from where the unit was purchased AC MAINS VOLTAGE SETTING FUSE RATING 220 230 VAC T 1A 250V 100 120 VAC T 3 15A 250V Technical Specification Mains Input Voltage Settings 230 220 120 100 VAC 47 63 Hz Power consumption max 150W Mains Fuse Rating 100 120 V Use T 3 15A 250V 20mm 220 240 V Use T 1A 250V 20mm Outputs DC Voltage Rail Output Current 16 VO