Home

Infiniium Oscilloscopes Application Software

image

Contents

1. E Infinitum Upgrade and Recovery Guide For detailed upgrade and recovery instructions find the section of this document that pertains to your particular model number If your model number is not printed on your scope s front panel it should be printed near the serial number on the rear panel Upgrade and recovery software is available free of charge at http software cos agilent com Infiniium Except where otherwise noted this software is not available for download and the media must be physically delivered to you Upgrade software will update the oscilloscope application leaving the operating system and user files intact Recovery software will erase all data on the hard drive and install a fresh disk image A system recovery is a good first step in troubleshooting any problem that you believe might be software related Quick links For models 54810A 54815A 54820A 54825A 54835A 54845A 54846A For models 54845B and 54846B For models 54830B 54830D 54831B 54831D 54832B 54832D 54833A 54833D For models 54853A 54854A and 54855A For models 54810A 54815A 54820A 54825A 54835A 54845A and 54846A Some of these units will require hardware upgrades before a system recovery or certain software upgrades are possible For pricing and availability of any required parts please visit http www parts agilent com or call Agilent Parts Ordering at 877 447 7278 To determine your scope s upgradeability Locate the t
2. center repair Alternatively some customers have been successful using third party external CD ROM drives The preferred method of recovery is via installation of the LS 120 upgrade kit listed above If your scope has this drive order the 3 5 Recovery for VIN 25 Media LS 120 A second method is to replace the hard drive with a drive that has the operating system and software preinstalled Since hard drive part numbers tend to change with time contact Agilent Parts for the most recent part number Consult your scope s service manual for detailed hard drive replacement instructions Service manuals are available for download at http www cos agilent com manuals scopes html A third method is to have the Agilent service center perform the recovery Contact the service center at 800 829 4444 to schedule this repair choose the repair and calibration option in the phone menu A fee will be assessed for units that are no longer under warranty Some customers have been successful performing system recoveries with external CD ROM drives from companies such as MicroSolutions These drives connect to the scope s parallel port Since this method of recovery is unsupported by Agilent customers are responsible for all configuration of the external drive For the recovery to be possible you will need to mount the external drive and boot the scope from a floppy disk the drive s manufacturer may be able to provide this disk for you At th
3. that you also upgrade your scope s system RAM to 64 MB Software revisions A 04 00 and higher will not run reliably with less than 64 MB memory The memory upgrade requires two 32 MB 72 pin DRAM SIMM chips You can order these chips from Agilent buy quantity 2 of part number 1818 7682 or from a third party vendor Many customers have been successful using RAM chips from various memory manufacturers Important note Your motherboard s memory must be installed in pairs Do not install single memory chips This additional RAM will allow advanced features such as WebEnable to run reliably But because of the slower processors in these machines performance and responsiveness will not be as good as that of the newer faster machines For complete instructions on installing the two 32 MB SIMMs and making appropriate adjustments to the BIOS please refer to Service Note 54810A 06 at http literature agilent com litweb pdf 548 10A 06 pdf System recovery Officially there are three methods of recovery available to customers LS 120 recovery hard drive replacement and service center repair Alternatively some customers have been successful using third party external CD ROM drives The preferred method of recovery is via installation of the LS 120 upgrade kit listed above If your scope has this drive order the 3 5 Recovery VIN 025 Media LS 120 Note that a VIN 020 version is not available since the great majority of these scopes do not ha
4. D save contents to floppy ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec bootdisk CD_boot zip A 04 30 Upgrade files burn contents to CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_3 4_3_upg zip A 04 50 Upgrade files burn contents to CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_5 4_5_upg zip For models 54845B and 54846B Since these newer models have integrated CD ROM drives upgrades and recoveries are very straightforward System recovery Order the most recent revision of Recovery CD that is available Software upgrade Order the most recent revision of the Upgrade LS 120 that is available For models 54830B 54830D 54831B 54831D 54832B 54832D 54833A 54833D These models were originally released with the Windows 98 operating system Newer units and upgraded older units run Windows XP Your scope s operating system will determine which upgrade or recovery CDs are appropriate for it To determine your operating system click Help About Infinitum and look in the SYSTEM CONFIGURATION section System recovery Windows 98 Order the most recent revision of Recovery CD that is available Software upgrade Windows 98 Order the most recent revision of the Upgrade CD that is available revision A 02 30 as of this writing Note that no further software updates are planned for Windows 98 users To take advantage of software updates to revision A 03 00 or hi
5. MB RAM you can upgrade the software to the most recent revision A 04 50 as of this writing Order the appropriate Upgrade disk s available on LS 120 media or download this software from the locations listed below If you choose to download the software you will need to transfer all the files in each ZIP file to a blank LS 120 disk Then perform the upgrade in the usual manner click Utilities Upgrade Software Note that the A 04 50 LS 120 upgrade is a partial upgrade that does not contain the WebEnable software To use the WebEnable feature you must upgrade to A 04 30 before using the A 04 50 upgrade A 04 30 Upgrade ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_3 4_3_upg zip A 04 50 Upgrade ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_5 4_5_upg zip 6 If your scope does not have an LS 120 drive but you do have a working external CD ROM drive as mentioned in System recovery above it is possible to upgrade to revision A 04 00 or higher To do this you must first upgrade your scope s system RAM to 64 MB as described above To upgrade your non LS 120 scope to A 04 xx you will need the A 04 xx upgrade software on CD and the appropriate boot disk on a 3 5 floppy You may contact Agilent technical support for copies of these disks or download the files at the locations given below The boot disk supports the MicroSolutions model 167550 Backpack CD ROM drive You may need to modify th
6. ain the WebEnable software To use the WebEnable feature you must upgrade to A 04 30 before using the A 04 50 upgrade Boot disk for A 04 xx upgrade from CD save contents to floppy ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec bootdisk CD_boot zip A 04 30 Upgrade files burn contents to CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_3 4_3_upg zip A 04 50 Upgrade files burn contents to CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_5 4_5_upg zip 4 If the VIN number is 020 When your scope shipped from the factory it did not have the LS 120 120 MB floppy drive Officially this drive is required to upgrade the scope to revision A 04 00 or higher The drive also makes it possible to perform a system recovery from LS 120 media You can easily identify the LS 120 drive by the gold icon in the center of the drive door LS 120 drives also have an electronic not mechanical eject button If your scope has a standard floppy drive you should consider upgrading to the LS 120 drive This drive will allow you to easily perform upgrades and system recoveries that are officially supported To upgrade your scope you will need to purchase the E2633 68703 upgrade kit The kit includes the LS 120 drive all necessary hardware for mounting and connecting the drive and an LS 120 disk containing the most recent revision of software If you upgrade to the LS 120 drive we highly recommend
7. at case you will need to recover from CDs Software upgrade Windows XP Order the most recent revision of the Upgrade CD that is available We also highly recommend that you visit Microsoft s Windows Update page and install all available Critical Updates and Service Packs for Windows XP Check the site periodically for new updates or subscribe to Automatic Updates when prompted We do not recommend that you install updates from the Windows XP or Driver Updates categories To get started with Windows Update open Internet Explorer and click Tools Windows Update For models 54853A 54854A 54855A System recovery If your scope originally shipped with software revision A 03 10 or higher no recovery CD is necessary A hidden partition on your hard drive contains the recovery system To perform a system recovery follow these steps 1 With the keyboard and mouse connected turn on the scope 2 When the Agilent Technologies splash screen appears hold down one of the Ctrl keys 3 When the Recovery screen appears release the Ctrl key 4 Select Recover System from the Boot Menu and press Enter 5 Follow the on screen instructions If your scope originally shipped with software revision A 03 00 or A 03 01 order the most recent revision of the Recovery CD that is available 10 If you are not sure which of the above cases applies to your scope the easiest way to tell is to attempt to recover from the hidden partition
8. by following steps 1 5 above If the hidden partition does not exist the recovery console will not load and the scope will boot to Windows In that case you will need to recover from CDs Software upgrade Order the most recent revision of the Upgrade CD that is available We also highly recommend that you visit Microsoft s Windows Update page and install all available Critical Updates and Service Packs for Windows XP Check the site periodically for new updates or subscribe to Automatic Updates when prompted We do not recommend that you install updates from the Windows XP or Driver Updates categories To get started with Windows Update open Internet Explorer and click Tools Windows Update By internet phone or fax get assistance with all your test amp measurement needs Online assistance http www agilent com find assist Phone or Fax United States Europe Latin America tel 800 452 4844 tel 31 20 547 2323 tel 305 269 7500 fax 31 20 547 2390 fax 305 269 7599 Canada tel 877 894 4414 Japan Taiwan fax 905 282 6495 tel 81 426 56 7832 tel 0800 047 866 fax 81 426 56 7840 fax 0800 286 331 China tel 800 810 0189 Korea Other Asia Pacific Countries fax 800 820 2816 tel 82 2 2004 5004 tel 65 6375 8100 fax 82 2 2004 5115 fax 65 6836 0252 Email tm_asia agilent com 5 Agilent Email Updates www agilent com find emailupdates Get the latest information
9. e DOS prompt you must be able to navigate to the drive and see the drive s contents with the dir command If you can successfully get to this point you should be able to perform a recovery with a special A 03 50 recovery CD You may download the CD image at the location given below or contact Agilent technical support for a copy of this CD The following recovery software is available for download This is an SO CD ROM image file You will need to use CD burning software such as Nero or Easy CD Creator to create the CD from this file Do not simply copy the file onto the CD as this will not work A 03 50 Recovery CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 3_5 3_5_rec iso 3 Software upgrade If your scope does not have the LS 120 drive order the latest Upgrade disk that is available on 3 5 Floppy media revision A 03 72 as of this writing Versions A 04 00 and higher are not offered on standard 3 5 floppies Alternatively you may download the A 03 72 upgrade at the following location You will need ten blank floppy disks labeled 1 through 10 When you execute the file it will create ten folders one for each disk Copy the contents of each folder to the corresponding disk and then perform the upgrade in the usual manner click Utilities Upgrade Software ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 3_72 3_72_upg exe If you have upgraded your scope to an LS 120 drive you can upgrade the s
10. e files for compatibility with your drive Note that the A 04 50 LS 120 upgrade is a partial upgrade that does not contain the WebEnable software To use the WebEnable feature you must upgrade to A 04 30 before using the A 04 50 upgrade Boot disk for A 04 xx upgrade from CD save contents to floppy ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec bootdisk CD_boot zip A 04 30 Upgrade files burn contents to CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_3 4_3_upg zip A 04 50 Upgrade files burn contents to CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_5 4_5_upg zip If the VIN number is 015 or does not exist Your scope is among the oldest Infinitum units When your scope shipped from the factory it did not have the LS 120 120 MB floppy drive You can easily identify the LS 120 drive by the gold icon in the center of the drive door LS 120 drives also have an electronic not mechanical eject button Your scope should not have an LS 120 drive and we recommend that you do not attempt to install one Your scope s BIOS will not recognize the drive and we have no means of updating the BIOS System recovery Officially there are two methods of recovery available to customers hard drive replacement and service center repair Alternatively some customers have been successful using third party external CD ROM drives One method of recovery is to replace the hard dri
11. for a copy of this CD The following recovery software is available for download This is an SO CD ROM image file You will need to use CD burning software such as Nero or Easy CD Creator to create the CD from this file Do not simply copy the file onto the CD as this will not work A 03 50 Recovery CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 3_5 3_5_rec iso Software upgrade As shipped from the factory these scopes have a maximum of 16 MB RAM which is inadequate for running the most recent revision of software If your scope s hardware is unmodified and you do not wish to modify it order the latest Upgrade disk that is available on 3 5 Floppy media revision A 03 72 as of this writing Versions A 04 00 and higher will not run reliably on these machines and are not offered on standard 3 5 floppies Alternatively you may download the A 03 72 upgrade at the following location You will need ten blank floppy disks labeled 1 through 10 When you execute the file it will create ten folders one for each disk Copy the contents of each folder to the corresponding disk and then perform the upgrade in the usual manner click Utilities Upgrade Software ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 3_72 3_72_upg exe If you have an external CD ROM drive as mentioned in System recovery above it is possible to upgrade to revision A 04 00 or higher To do this you must first upgrade your scope s sys
12. gher we strongly recommend that you purchase our N5383A Infinitum Performance Upgrade Kit This kit upgrades your scope to Windows XP Pro increases system RAM from 256 MB to 512 MB and allows you to run Windows applications inside the scope System recovery Windows XP If your scope originally shipped with Windows XP no recovery CD is necessary A hidden partition on your hard drive contains the recovery system To perform a system recovery follow these steps 1 With the keyboard and mouse connected turn on the scope When the Agilent Technologies splash screen appears hold down one of the Ctrl keys 3 When the Recovery screen appears release the Ctrl key 4 Select Recover System from the Boot Menu and press Enter 5 Follow the on screen instructions If your scope originally shipped with Windows 98 and was upgraded to Windows XP your N5383A upgrade CD package is your recovery set To perform a recovery simply install the Windows XP upgrade as per the original instructions Under our agreement with Microsoft we are generally not able to send customers free replacement CDs If you have lost your CDs contact Agilent technical support If you are not sure which of the above cases applies to your scope the easiest way to tell is to attempt to recover from the hidden partition by following steps 1 5 above If the hidden partition does not exist the recovery console will not load and the scope will boot to Windows In th
13. hree digit VIN number and serial number on the rear panel of the scope Then see the section below that applies to your unit Note that some older units do not have a VIN number Quick links If the VIN number is 030 031 032 or 033 If the VIN number is 025 and the serial number prefix is US3919 or greater If the VIN number is 025 and the serial number prefix is less than US3919 If the VIN number is 020 If the VIN number is 015 or does not exist If the VIN number is 030 031 032 or 033 Your scope has a hardware configuration that allows easy upgrading to the most recent revision of software version A 04 50 as of this writing You can also easily perform a system recovery on this scope Important note If your scope s VIN is 030 031 or 032 please see Service Note 54845A 07A Correct Intermittent Lockups Caused By the Motherboard etc These units should be upgraded to VIN 033 via motherboard replacement EE Agilent Technologies System recovery Order the most recent revision of Recovery disk available on LS 120 media version A 04 30 as of this writing Do not attempt to use the 3 5 Recovery disks as the newer motherboard in these scopes requires the newer disk image Software upgrade Order the most recent revision of the Upgrade disk available on LS 120 media or download this software from the locations listed below If you choose to download the software you will need to transfer all the file
14. oftware to the most recent revision A 04 50 as of this writing Order the appropriate Upgrade disk s available on LS 120 media or download this software from the locations listed below If you choose to download the software you will need to transfer all the files in each ZIP file to a blank LS 120 disk Then perform the upgrade in the usual manner click Utilities Upgrade Software Note that the A 04 50 LS 120 upgrade is a partial upgrade that does not contain the WebEnable software To use the WebEnable feature you must upgrade to A 04 30 before using the A 04 50 upgrade A 04 30 Upgrade ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_3 4_3_upg zip A 04 50 Upgrade ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_5 4_5_upg zip If your scope does not have an LS 120 drive but you do have a working external CD ROM drive as mentioned in System recovery above it is possible to upgrade to revision A 04 00 or higher To upgrade your non LS 120 scope to A 04 xx you will need the A 04 xx upgrade software on CD and the appropriate boot disk on a 3 5 floppy You may contact Agilent technical support for copies of these disks or download the files at the locations given below The boot disk supports the MicroSolutions model 167550 Backpack CD ROM drive You may need to modify the files for compatibility with your drive Note that the A 04 50 LS 120 upgrade is a partial upgrade that does not cont
15. on the products and applications you select Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 2004 Printed in USA August 1 2004 11
16. s in each ZIP file to a blank LS 120 disk Then perform the upgrade in the usual manner click Utilities Upgrade Software Note that the A 04 50 LS 120 upgrade is a partial upgrade that does not contain the WebEnable software To use the WebEnable feature you must upgrade to A 04 30 before using the A 04 50 upgrade A 04 30 Upgrade ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_3 4_3_upg zip A 04 50 Upgrade ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_5 4_5_upg zip If the VIN number is 025 and the serial number prefix is US3919 or greater Your scope has a hardware configuration that allows easy upgrading to the most recent revision of software version A 04 50 as of this writing You can also easily perform a system recovery on this scope System recovery Order 3 5 Recovery VIN 025 Media LS 120 Do not attempt to use the 4 30 Recovery disks as the older motherboard in these scopes requires the older disk image Once you have recovered to A 03 50 you can safely upgrade to the latest revision A 04 50 as of this writing Software upgrade Order the most recent revision of the Upgrade disk available on LS 120 media or download this software from the locations listed below If you choose to download the software you will need to transfer all the files in each ZIP file to a blank LS 120 disk Then perform the upgrade in the usual manner click Utilities Upgrade Software Note
17. tem RAM to 64 MB which requires two 32 MB 72 pin DRAM SIMM chips You can order these chips from Agilent buy quantity 2 of part number 1818 7682 or from a third party vendor Many customers have been successful using RAM chips from various memory manufacturers Important note Your motherboard s memory must be installed in pairs Do not install single memory chips This additional RAM will allow advanced features such as WebEnable to run reliably But because of the slower processors in these machines performance and responsiveness will not be as good as that of the newer faster machines For complete instructions on installing the two 32 MB SIMMs and making appropriate adjustments to the BIOS please refer to Service Note 54810A 06 at http literature agilent com litweb pdf 548 10A 06 pdf To upgrade your non LS 120 scope to A 04 xx you will need the A 04 xx upgrade software on CD and the appropriate boot disk on a 3 5 floppy You may contact Agilent technical support for copies of these disks or download the files at the locations given below The 8 boot disk supports the MicroSolutions model 167550 Backpack CD ROM drive You may need to modify the files for compatibility with your drive Note that the A 04 50 LS 120 upgrade is a partial upgrade that does not contain the WebEnable software To use the WebEnable feature you must upgrade to A 04 30 before using the A 04 50 upgrade Boot disk for A 04 xx upgrade from C
18. th a special A 03 50 recovery CD You may download the CD image at the location given below or contact Agilent technical support for a copy of this CD The following recovery software is available for download This is an ISO CD ROM image file You will need to use CD burning software such as Nero or Easy CD Creator to create the CD from this file Do not simply copy the file onto the CD as this will not work A 03 50 Recovery CD ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 3_5 3_5_rec iso Software upgrade As shipped from the factory these scopes have a maximum of 16 MB RAM which is inadequate for running the most recent revision of software If your scope s hardware is unmodified and you do not wish to modify it order the latest Upgrade disk that is available on 3 5 Floppy media revision A 03 72 as of this writing Versions A 04 00 and higher will not run reliably on these machines and are not offered on standard 3 5 floppies Alternatively you may download the A 03 72 upgrade at the following location You will need ten blank floppy disks labeled 1 through 10 When you execute the file it will create ten folders one for each disk Copy the contents of each folder to the corresponding disk and then perform the upgrade in the usual manner click Utilities Upgrade Software ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 3_72 3_72_upg exe If you have upgraded your scope to an LS 120 drive and 64
19. that the A 04 50 LS 120 upgrade is a partial upgrade that does not contain the WebEnable software To use the WebEnable feature you must upgrade to A 04 30 before using the A 04 50 upgrade A 04 30 Upgrade ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_3 4_3_upg zip 2 A 04 50 Upgrade ftp ftp agilent com pub callpub 1 ddt scope 548xx Upg_Rec 4_5 4_5_upg zip If the VIN number is 025 and the serial number prefix is less than US3919 When your scope shipped from the factory it did not have the LS 120 120 MB floppy drive Officially this drive is required to upgrade the scope to revision A 04 00 or higher The drive also makes it possible to perform a system recovery from LS 120 media You can easily identify the LS 120 drive by the gold icon in the center of the drive door LS 120 drives also have an electronic not mechanical eject button If your scope has a standard floppy drive you should consider upgrading to the LS 120 drive This drive will allow you to easily perform upgrades and system recoveries that are officially supported To upgrade your scope you will need to purchase the E2633 68703 upgrade kit The kit includes the LS 120 drive all necessary hardware for mounting and connecting the drive and an LS 120 disk containing the most recent revision of software System recovery Officially there are three methods of recovery available to customers LS 120 recovery hard drive replacement and service
20. ve the LS 120 drive The VIN 025 Recovery is the correct version for your VIN 020 scope A second method is to replace the hard drive with a drive that has the operating system and software preinstalled Since hard drive part numbers tend to change with time contact Agilent Parts for the most recent part number Consult your scope s service manual for detailed hard drive replacement instructions Service manuals are available for download at http www cos agilent com manuals scopes html A third method is to have the Agilent service center perform the recovery Contact the service center at 800 829 4444 to schedule this repair choose the repair and calibration option in the phone menu A fee will be assessed for units that are no longer under warranty Some customers have been successful performing system recoveries with external CD ROM drives from companies such as MicroSolutions These drives connect to the scope s parallel port Since this method of recovery is unsupported by Agilent customers are responsible for all configuration of the external drive For the recovery to be possible you will need to mount the external drive and boot the scope from a floppy disk the drive s manufacturer may be able to provide this disk for you At the DOS prompt you must be able to navigate to the drive and see the drive s contents with the dir command If you can successfully get to this point you should be able to perform a recovery wi
21. ve with a drive that has the operating system and software preinstalled Since hard drive part numbers tend to change with time contact Agilent Parts for the most recent part number Consult your scope s service manual for detailed hard drive replacement instructions Service manuals are available for download at http www cos agilent com manuals scopes html A second method is to have the Agilent service center perform the recovery Contact the service center at 800 829 4444 to schedule this repair choose the repair and calibration option in the phone menu A fee will be assessed for units that are no longer under warranty Some customers have been successful performing system recoveries with external CD ROM drives from companies such as MicroSolutions These drives connect to the scope s parallel port Since this method of recovery is unsupported by Agilent customers are responsible for all configuration of the external drive 7 For the recovery to be possible you will need to mount the external drive and boot the scope from a floppy disk the drive s manufacturer may be able to provide this disk for you At the DOS prompt you must be able to navigate to the drive and see the drive s contents with the dir command If you can successfully get to this point you should be able to perform a recovery with a special A 03 50 recovery CD You may download the CD image at the location given below or contact Agilent technical support