CENTURY PUMP ASSEMBLIES
Contents
1. are included in 0115 010300 AX140 Hardware Kit BINK MODELS CX2006 amp CX2017HC CENTURY PUMP ASSEMBLIES BITIKS MODELS 2006 amp CX2017HC CENTURY PUMP ASSEMBLIES ITEM PART TY TY PART arses ar 3 RATWAHR BET 3 zw 3 3 4 93704 HEX HEAD CAP sem 4 s 0 41 RAWAHR 2 1 T REAR caTabs PUMP BRACKET AA B s 001950 Carauvsr un assema ra 1 wmm W 71927 STUO 0 0 0 0 0 2 2 12 237176 HEXHEADCAPSREW 3 3 13 101 9430 RRONTCATADSTPUMPBRAGET ER AX85SD 8 FRX20HC BARE PUMP ASSEMBLY 1 CRX2017HC AX140SD amp FRX20HC BARE PUMP ASSEMBLY a 15 203071 1 ALENHEADCAPSCREW f a 4 16 72237 DMNPPE 3 1 j 17 dw 3 18 287205 NYLOKHEXNUT 8 J 8 Jj 2 WALL MOUNTING PATTERN CENTURY PUMP DIMENSIONS WARRANTY This product is covered by Binks 1 Year Limited Warranty Binks Sales and Service www binks com BITIKS U S A Canada Customer Service Toll Free Customer Service 195 Internationale Blvd Pl support Glendale Heights IL 60139 630 237 5000 Toll Free Fax 888 246 5732 3 13 77 2940R 1 Revisions Trademark updates P8 Updated contact information 2013 Binks All rights res
2. BIfIKS CENTURY PUMP ASSEMBLIES MODELS CX2006HC 6 5 1 CX2017HC 17 1 CX2006HC CX2017HC Do O TS Air consumption 20 cycles min and 116 psi 5 2 SCFM 147 LPM 17 6 SCFM 498 LPM 8 bar air inlet pressure Maximum fluid pressure 750 psi 52 bar 1970 psi 136 bar Displacement per cycle 4 3 oz 127 cc 4 3 oz 127 cc 160 F 71 160 F 71 C 3 8 BSP P 3 8 BSP F T 1 1 4 NPT M amp 1 1 4 NPT M amp Fluid inlet connection 1 NPT F 1 NPT F Fluid outlet connection 1 2 NPT NPS M 1 2 NPT NPS M Replaces Part Part Sheet Sheet 77 2940R 77 2940R 1 BITIKS In this part sheet the words WARNING CAUTION and NOTE are used to emphasize important safety information as follows A WARNING A CAUTION Hazards or unsafe practices which could Hazards or unsafe practices which could Important installation operation or result in severe personal injury death or result in minor personal injury product maintenance information substantial property damage or property damage A WARNING Read the following warnings before using this equipment READ THE MANUAL Before operating finishing equipment read and understand all safety operation and maintenance information provided in the operation manual PLURAL COMPONENT MATERIALS HAZARD Because of the vast number of chemicals that could be used and their varying chemical reactions the buyer and user of this equipment must determ
3. T PARTS The pump is designed to use authorized parts only When using this pump with parts that do not comply with the minimum specifications and safety devices of Binks the user assumes all risks and liabilities WARNING EXCESSIVE AIR PRESSURE Can cause personal injury pump dam age or property damage Do not exceed maximum inlet air pressure as stated on motor model plate BINK MODELS CRX2006 amp CRX2017HC CENTURY BARE PUMP ASSEMBLIES BITIKS MODELS CRX2006 amp CRX2017HC CENTURY BARE PUMP ASSEMBLIES ITEM QTY QTY PART PARE HESS E CRX2006HC CRX2017HC SHEET ea E E 4 oas fa s posu axraoso AX1405D AIR MOTOR ASSEMBLY 1 772988 ES nn a 7 sse 1 1 s oris o10001 v socket Hea 3 s emsowwa a sockermea 19 3 n ww 3 m ww spur couar seve 1 5 zs 1 1 a ors mororooo 15 aes oD ADAPTER 1 1 1 1 wu 1on sa20 Pume RoD aD abater 1 1 1 101 9439 O 1 1 19 20 6872 sockeTHeaD capscrew 4 39 orsa ADAPTER PLATE 1 1 Y Parts are included in 0115 010213 AX85 Hardware Kit amp Parts
4. erved Printed in U S A
5. ine all facts relating to the materials used including any of the potential hazards involved NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment WEAR SAFETY GLASSES Failure to wear safety glasses with side shields could result in serious eye injury or blindness DE ENERGIZE DEPRESSURIZE DISCONNECT AND LOCK OUT ALL POWER SOURCES DURING MAINTENANCE Failure to De energize disconnect and lock out all power supplies before performing equipment maintenance could cause serious injury or death FIRE AND EXPLOSION HAZARD Improper equipment grounding poor ventilation open flame or sparks can cause hazardous conditions and result in fire or explosion and serious injury PINCH POINT HAZARD Moving parts can crush and cut Pinch points are basically any areas where there are moving parts OPERATOR TRAINING All personnel must be trained before operating finishing equipment EQUIPMENT MISUSE HAZARD KNOW WHERE AND HOW TO SHUT OFF THE Equipment misuse can cause the equipment to EQUIPMENT IN CASE OF AN EMERGENCY rupture malfunction or start unexpectedly and result in serious injury aG PRESSURE RELIEF PROCEDURE Always follow the pressure relief procedure in the equipment instruction manual KEEP EQUIPMENT GUARDS IN PLACE Do not operate the equipment if the safety devices have been removed HIGH PRESSURE CONSIDERATION PROP 65 WARNING High pressu
6. re can cause serious injury Relieve all CA PROP pressure before servicing Spray from the spray gun hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PROVIDE THIS INFORMATION TO THE OPERATOR OF THE EQUIPMENT FOR FURTHER SAFETY INFORMATION REGARDING BINKS AND DEVILBISS EQUIPMENT SEE THE GENERAL EQUIPMENT SAFETY BOOKLET 77 5300 N BIMKS HIGH PRESSURE CAN CAUSE SERIOUS INJURY IF EQUIPMENT IS INSTALLED OR USED INCORRECTLY READ UNDERSTAND AND OBSERVE ALL WARNINGS AND INSTRUCTIONS IN THIS MANUAL INSTALL OPERATE OR SERVICE THIS EQUIPMENT ONLY AFTER ALL INSTRUCTIONS ARE CLEARLY UNDERSTOOD It is the responsibility of the employer to place this information into the hands of the operator WARNING Hazards or unsafe practices which could result in severe personal injury death or substantial property damage AVOID STATIC SPARKING 1 Use Binks NO WIRE conductive hose in all airless spraying operations Be sure the gun and hose have continuity 2 Make sure the pump is grounded NEVER operate the unit when it 1s on a non grounded platform 3 When flushing or cleaning with a combustible solvent always use an open metallic container for receiving the waste solvent Ground
7. the solvent receptacle 4 ALWAYS remove spray tip when flushing the system Operate the pump at the lowest possible pressure Open Metallic Conductive Hose Waste Solvent To Airless Pump Container gt Grounded Bonding Wire Gun To Solvent Container 44 CAUTION Hazards or unsafe practices which could result in minor personal injury product or property damage GENERAL WARNINGS 1 NEVER leave a pressurized sprayer unattended 2 Periodically inspect all hoses for leaks and or abrasions and tighten all connections before use DO NOT ATTEMPT TO REPAIR a defective hose REPLACE it with another conductive hose 3 ALWAYS relieve pressure in the system by turning bypass valve to BYPASS or triggering spray gun before disassembly of any component parts CAUTION Never store de ionized distilled reverse osmosis or any pure grade of water in the pump These fluids may cause corrosion BINKS is not responsible for misapplica tion of pumps Consult your BINKS repre sentative for application assistance NOTE Important installation operation or maintenance information Be sure that all fluids solvents and fillers to be used are chemically and physically compatible with wetted parts in the pump Consult your BINKS representative for pump materials of constructions and compatibility infor mation Consult the fluid manufacture for information regarding the fluids to be used REPLACEMEN