Contents
1. 1 bit R 1 001 Status feedback of the cooling feature output Control input to switch position of 6 WAY VALVE outputs To switch position send telegram with number of desired valve position 1 position closed 2 position backwash 3 position recirculate 4 position waste 5 position filter 6 position rinse Actual position will be send via status feedback object 10 2 10 LVLO 6 Way Valve Control Input control EIS5 2 Byte w Le Display actual position of 6 WAY VALVE output Telegram with position is send on change and cyclically every 600s Position values 1 position closed 10 2 11 LVLO 6 Way Valve Status Feedback display of value EIS5 2 Byte R Le 2 position backwash 3 position recirculate 4 position waste 5 position filter 6 position rinse Control actual pool mode To switch mode send telegram with number of desired mode 1 in use 10 2 12 LVLO Pool Mode Control Input control EIS5 2 Byte Ww za 2 closed 3 winter NOTE service mode can be controlled only from device LCD panel Display current pool mode via status feedback value Telegram with current mode number is send to bus on change and cyclically every 600s 10 2 13 LVLO Pool Mode Control Output display of value EIS5 2 Byte R 7 1 pool in use 2 pool closed 3 pool winter mode 4 pool service mode Actuator to control 3 WAY VALVE output Toggle current output state open closed when pulse
2. Redox Output mV display of value EIS5 2 Byte R 9 020 Value is send to bus on change or cyclically based on parameter 10 2 15 Display actual CLF Free chlorine value in mg l ppm 10 0 14 LVLO Current Actual Free Chlorine Output mg l display of value EIS5 2 Byte R 9 Floating value is send to bus on change or cyclically based on parameter 10 2 15 LVLO Current External System Temperature i 10 0 15 Output C display of value EIS5 2 Byte R 9 001 Display actual temperature of external heating cooling system Floating value C is cyclically send to bus ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www Ivl0 eu www lvl0 eu KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 7 of 13 LVLO ULTIMATE POOL CONTROLLER BY SA 4 1 2 LVL KNX INTEGRATION MANUAL 10 1 x Communication objects for Dashboard section Ree Data Point Name Data Point Type Description LVLO Service Required Status Feedback Summarized status feedback object to display if service 10 1 0 1 Required oe display of status 1 bit 1 001 intervention on pool is required Telegram is send TAEA ai cyclically to bus every 600s Summarized status feedback object to display service code in case of service is required on pool Telegram A i with code is send to
3. bus cyclically every 600s Code 10 1 1 oo Area Status Feedback 0 OK display of value EIS5 2 Byte 77 explanation gig 1 water quality long term OK ERR 2 technology OK ERR 4 service intervals OK ERR Summarized status feedback object to display exact service code in case of Circuit breakers failure Telegram wata with code is send to bus cyclically every 600s Code 10 1 2 Eri Breakers status Feedback 05O display of value EIS5 2 Byte ris explanation a 1 dosing breaker failure OK ERR 2 filtration breaker failure OK ERR 4 additional technology breaker failure OK ERR Summarized status feedback object to display exact service code in case of water treatment issues Telegram with code is send to bus cyclically every 600s Code explanation 10 1 3 LVLO Water Treatment Status Feedback display of value EIS5 2 Byte yA 1 pH OK ERR 2 ORP CLF OK ERR 4 chemical stocks OK ERR 8 electrodes OK ERR Display actual status of outputs for DOSING PUMPS 1 4 FILTRATION 3 WAY VALVE and MAKE UP WATER VALVE Summarized status telegram is send to bus on change and cyclically every 600s Code explanation 1 filtration pump ACTIVE INACTIVE 10 1 4__ LVLO Pump and Valves Status Feedback display of value EIS9 2 Byte 16 2 dosing pump 1 ACTIVE INACTIVE 4 dosing pump 2 ACTIVE INACTIVE 8 dosing pump 3 ACTIVE INACTIVE 16 dosing pump 4 ACTIVE INACTIVE 32 heating valve OPEN CLOSE 64 make up w
4. 0 1 19 LVLO Salt Chlorine Generator Status Feedback display of status 1 bit 1 005 Status yA display SALT GENERATOR output state elegram is send cyclically to the bus every 600s 4 1 3 Group Address 10 2 x Communication objects for Settings and Service section Data Point Name Data Point Type Description Actuator to control FILTRATION output Toggle SADI 5 current output state when pulse edge telegram 0 1 10 2 0 LVLO Filtration Pump Control Send 1 0 control pulse edge 1 0 1 bit 1 001 will be received on this input Status feedback will be send when output changes state 10 2 1 eae 7 non Pump Status Feedback display of status 1 bit 1 001 Status feedback of FILTRATION output Actuator to control filter cleanup backwash process Detailed backwash process can be set via service menu 10 2 2 ilter Cleanup Control Send 1 0 control pulse edge 1 0 1 bit 1 001 of the LVL mobile app To initiate start backwash pulse edge telegram 0 1 need to be send to this input Status feedback will be send when the process is running 10 2 3 oe ter Cleanup Status Feedback 1 On display of status 1 bit 1 001 Status feedback of the filter cleanup backwash process R m Control water temperature set point from KNX 10 2 4 LVLO Water Temperature Setpoint Input C control EIS5 2 Byte 9 001 Floating value C will adjust desired water temperature A A Display actual water tempera
5. 15 015 from bus low 1 1222 1 1222 LVLO 10 17 LVLO Buffer Tank Water Level Status Feedback 6 Write 77 2 byte unsigned value 05 DC 29 2015 02 08 11 56 15 131 from bus low 11 222 11222 LULO 10 1 73 LVLO Water Treatment Status Feedback 6 Write 7 2 byte unsigned value 01 F4 30 2015 02 08 11 56 15 322 from bus Low 1 1 222 11 vo 10 1 0 LVLO Service Required Status Feedback 1 Required 0 0K Write 1 005 alarm 01 Alarm 31 2015 02 08 11 56 15 527 from bus low 11222 1 1222 LVLO 10 19 LVLO Sensors Status Feedback 6 Write 8 2 byte signed vale 0190 32 2015 02 08 11 56 15 733 from bus low 1 1222 1 1222 LVLO 10 1 11 LVLO pH Electrode Service in Day Status Feedback 6 Write 14 4 byte float value 000000000 33 2015 02 08 11 56 32 935 from bus low 1 1 222 1 1222 LWLO 10 0 15 UVLO Current External System Temperature Output C 6 Write 9 001 temperature C 0000 0 C 34 2015 02 08 11 56 32 981 from bus Low 1 1 222 1 1 222 LVLO 10 0 12 LVLO Current Actual pH Output 6 Write 9 2 byte float value 03 64 668 35 2015 02 08 11 56 33 140 from bus low 1 1222 1 1222 LVLO 10 0 13 LVLO Current Actual Redox Output mV 6 Write 9 020 voltage mv 25 86 233 92 mv 36 2015 02 08 11 56 33 249 from bus low 19 222 1 1222 LVLO 10 0 14 UVLO Current Actual Free Chlorine Output mg l 6 Write 9 2 byte float value 0005 0 05 37 2015 02 08 11 57 06 119 from bus low 1 1 222 1 1222 LVLO 10 00 LVLO Water Temperature Output C 6 Write 9 001 temperature C OF OF 31 C 38 2015 0
6. 2 08 11 57 06 823 from bus low 11222 1 1222 LVLO 10 07 LVLO Poot Cover Status Feedback 1 Open OxClosed 6 Wie 1 tbat 00 39 2015 02 08 11 57 13 774 from bus low 11222 1 1222 LVLO 10 1 11 LVLO pH Electrode Service in Day Status Feedback 6 Write 14 4 byte float value 0000000010 officeisacontrolcom 1 1 25 Current project LVLO Message count 39 ISA s r o 2014 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www Ivl0 eu www lvl0 eu KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 10 of 13 LVLO KNX LVL KNX INTEGRATION MANUAL KNX ULTIMATE POOL CONTROLLER BY SA 4 2 1 4 2 2 4 2 3 1 bit output control To trigger LVL 1 bit output via KNX bus a toggle from 1 to 0 need to be send to the bus Example bus communication to control the output 10 0 3 Write 1 bit 1 send 1 to bus 10 0 3 Write 1 bit 0 send 0 to bus 10 0 4 Receive 1 bit 1 receive ON status of the output 10 0 3 Write 1 bit 1 send 1 to bus 10 0 3 Write 1 bit 0 send 0 to bus 10 0 4 Receive 1 bit 0 receive OFF status of the output 2 byte write and display value Change pool mode telegram with status feedback Print Replay Telegrams 8 2015 02 08 12 10 56 388 from bus Low 1 1 222 1 1 222 LVLO 10 2 13 LVLO Pool Mode Control Output 6 Write 7 2 byte unsigned value 00 C8 2 byte display status Display water temperatur
7. Adthorized Si udov t Zlaty Executive director ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www lvl0 eu www lvl0 eu KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 12 of 13 ISA INNOVATIVE SOLUTIONS ATELIER ISA s r o Pluhova 14 900 28 Ivanka pri Dunaji Slovak Republic http www lvl0 eu isa isacontrol com Phone numbers Slovakia global 421 2 3819 9150 France 0805 080 060 0977 550 060 Germany 0800 723 509 0 Spain 900 838 880 518 880 060
8. LVLO ULTIMATE POOL CONTROLLER BY ISA LVL KNX INTEGRATION MANUAL PLUG amp POOL www lvl0 eu LVLO KRX LVL KNX INTEGRATION MANUAL KNX ULTIMATE POOL CONTROLLER BY SA Contents 1 Safety information 4 1 1 Safety instructions 4 1 2 Information for electrically skilled persons 4 2 Overview 5 KNX Konnex and LVL 5 3 1 Electrical connection 6 3 2 Configuration 6 3 3 KNX network address 6 4 Engineering with ETS 7 4 1 KNX Group Addresses 7 4 1 1 10 0 x Communication objects for Home screen and statistics section 8 4 1 2 10 1 x Communication objects for Dashboard section 8 4 1 3 10 2 x Communication objects for Settings and Service section 9 4 2 Example communication 10 4 2 1 1 bit output control 11 4 2 2 2 byte write and display value 11 4 2 3 2 byte display status 11 EC Declaration of Conformity 12 6 Notes 13 ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www lvl0 eu www lvl0 eu PLUG amp POOL KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 2 of 13 LVLO KRR LVL KNX INTEGRATION MANUAL KNX ULTIMATE POOL CONTROLLER BY SA 1 1 1 1 2 Safety information Safety instruction Electrical equipment may only be installed and fitted by electrically skilled persons The country specific regulations and the valid guidelines must be followed Failure to observe the instructions
9. R output Pool cover 10 0 6 LVLO Pool Cover Control Close Send 1 0 control pulse edge 1 0 1 bit Ww 1 001 will close when pulse edge 0 1 telegram will be received on this input Status feedback of POOL COVER output is send to display of status 1 bit R 1 001 bus when the output change state Feedback is send cyclically to bus every 600s 0 Pool Cover Status Feedback 1 Open 10 0 7 losed Actuator to control AUX1 output Toggle current output status when pulse edge telegram 0 1 will be received on this input Status feedback will be send when output changes state 10 0 8 LVLO AUX1 Control Send 1 0 control pulse edge 1 0 1 bit WwW 1 001 10 0 9 LVLO AUX1 Status Feedback 1 On 0 Off display of status 1 bit R 1 001 Status feedback of AUX1 output Actuator to control AUX2 output Toggle current output status when pulse edge telegram 0 1 will be received on this input Status feedback will be send when output changes state 10 0 10 LVLO AUX2 Control Send 1 0 control pulse edge 1 0 1 bit WwW 1 001 10 0 11 LVLO AUX2 Status Feedback 1 On 0 Off display of status 1 bit R 1 001 Status feedback of AUX2 output Display actual pH value 10 0 12 LVLO Current Actual pH Output display of value EIS5 2 Byte R 9 Floating value is send to bus on change or cyclically based on parameter 10 2 15 Display actual Redox ORP value in mV 2000 2000 10 0 13 LVLO Current Actual
10. ater OPEN CLOSE Status to display issue with filling valve If max Make LVLO Buffer Tank Max Make Up Time Status i 4 up water safety time is reached alarm telegram is 103 Feedback 1 ERR 0 0K display of status TBI 1005 triggered Telegram is send cyclically to the bus every 600s Actuator to reset confirm Max Make up time issue When pulse edge 0 1 telegram will be received on LVLO Buffer Tank Max Make Up Time Reset A this input make up water valve will be again enabled 10 1 6 Send 1 0 control pulse edge 1 0 pols 1001 after reaching max Make up time set by LVL mobile application Counter of make up water duration will be reset to 0 Display actual water level in buffer tank based on setting in LVL mobile application H1 is on top of the tank H4 represent the lowest level Telegram with code A is send to bus cyclically every 600s Exact status codes 10 1 7 LVLO Buffer Tank Water Level Status Feedback display of value EIS5 2 Byte 7 1 buffer tank actual utilization H1 2 buffer tank actual utilization H2 4 buffer tank actual utilization H3 8 buffer tank actual utilization H4 Display safety messages when processing water in buffer tank Telegram with code is send to bus cyclically 3 every 600s Message codes 10 1 8 LVLO Buffer Tank Safety Status Feedback display of value EIS9 2 Byte 8 1 dry run protection ACTIVE INACTIVE 2 forced pumping ACTIVE INACTIVE 4 make up water ACTIVE INACTIVE S
11. e 1 1 222 1 1 222 LVLO Pool Controller KNX Serial BAOS 820 870 10 0 0 LVLO Water Temperature Output C 6 Write 9 001 temperature C OD F5 305 ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www lvl0 eu www lvl0 eu PLUG amp POO KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 11 of 13 LVLO KNX LVL KNX INTEGRATION MANUAL KNX ULTIMATE POOL CONTROLLER BY SA 1 EC Declaration of Conformity EC Declaration of Conformity ISA s r o Tolst ho 9 811 06 Bratislava Slovakia Declare with full responsibility that the product LVL Controller LVL Dosing Pumps L x U x wW Oo z x L iva wW N q 9 i j ia w oO Are confortable with resolutions of directives Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Electrical Equipment Directive 2006 95 EC CE Marking Directive 93 68 EEC And with the following norms EN 61439 3 2012 EN IEC 60947 5 IEC 60947 4 1 EN 60730 1 EN 61000 4 5 2006 IEC 60529 EN IEC 61008 1 EN 61095 2009 IEC 61000 3 12 EN 61000 3 3 2008 60947 4 1 IEC 60439 EN 61000 3 3 2008 EN 60730 6 2 2005 EN 61000 4 2 2009 EN 300 328 V1 7 1 2006 10 EN 61000 4 3 2006 A1 2008 A2 2008 A2 2010 EN 60730 6 3 2007 EN 6100 4 4 2004 A1 2010 Bratislava 15 10 2014 lt CC LLI
12. e EIS9 4 Byte 14 calibration replacement set via LVL mobile app Telegram with value cyclically send to bus every 600s ay Display days until next service on Free chlorine electrode 10 1 13 S ASA Service in Day Status display of value EIS9 4 Byte 14 calibration replacement set via LVL mobile app elegram with value cyclically send to bus every 600s ae Display hours until UV Lamp replacement set via LVLO 10 1 14 staring Service ln Moursistatus display of value EIS9 4 Byte 14 mobile app elegram with value cyclically send to bus every 600s VLO Ozone Generator Service in Day Status Display days until next service on ozone generator set 10 1 15 Feedback y display of value EIS9 4 Byte 14 via LVL mobile app elegram with value cyclically send to bus every 600s A KUA Display days until next service of salt chlorine generator 10 1 16 ieee ig lal Gen Servicsin Day Status display of value EIS9 4 Byte 14 set via LVL mobile app elegram with value cyclically send to bus every 600s Display days until next service on filtration unit filter 10 1 17 LVLO Filtration Service in Day Status Feedback display of value EIS9 4 Byte 14 set via LVL mobile app elegram with value cyclically send to bus every 600s VO Heat Pump Service in Day Status Display days until next service on heat pump or heat 10 1 18 Feedback p y display of value EIS9 4 Byte 14 exchanger set via LVL mobile app elegram with value cyclically send to bus every 600s 1
13. edge 10 2 14 LVLO Heating Valve Control Send 1 0 control pulse edge 1 0 1 bit 1 001 telegram 0 1 will be received on this input Use this input to control heating valve from master heating system Control interval for sending measured values control of value EIS5 2 Byte w 7 005 temperatures CLF pH ORP to bus Applies only to sensors LVLO Minimum Sensors Sending Interval 10 2 15 out s 4 2 Example communication Group Address E Data point type Raw up to 6 bit Value 0 Send cychcally Delay time sec 0 Recewed value Tne Service Flags Prio Sourceadde Source Destaddr Dest Rout Type DPT Linio 22 2015 02 08 11 56 14 040 from bus low 1 1222 1 1222 LVLO 10 1 17 LVLO Filtration Service in Day Status Feedback 6 Write 14 4 byte flost value 00000000 0 24 2015 02 08 11 56 14 278 from bus Low 1 1 222 1 1222 LVLO 10 2 11 LVLO 6 Way Valve Status Feedback 6 Write 7 2 byte unsigned value 01 F4 25 2015 02 08 11 56 14 378 from bus low 1122 14222 LVLO 10 2 5 LVLO Water Temperature Setpoint Output 6 Write 9001 temperature NC OE SE 326 C 26 2015 02 08 11 56 14 605 from bus low 11222 1 1222 LVLO 10 27 LVLO Water Temperature Setpoint Hysteresis Output C 6 Write 9 001 temperature C 0096 1 5 C 27 2015 02 08 11 56 14 811 from bus low 11222 1 1222 LVO 10 2 13 LVLO Poo Mode Control Output 6 Write 77 2 byte unsigned valve 00 64 28 2015 02 08 11 56
14. further 15 lines can branch off from each main line A network consisting of main lines and lines requires area and line couplers If no area and line couplers are used the network is restricted to one line Permissible bus topologies are tree line and star topologies These topologies can be mixed as required However ring topologies are not allowed The tree topology has advantages over other topologies in cases where a large network has to be created The bus cable comprises two twisted conductors CE red and CE black CE CE Unshielded bus cables are permitted for the KNX bus in conjunction with LVL device However shielded bus cables are recommended if high interference is anticipated The KNX bus uses CSMA CA CSMA Carrier Sense Multiple Access CA Collision Avoidance to access the bus With this method of access every bus user has equal data transmission rights There is no communication master in contrast to the master slave principle The data is exchanged directly peer to peer between bus users ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www lvl0 eu www lvl0 eu PLUG amp POOL KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 4 of 13 LVLO KNX LVL KNX INTEGRATION MANUAL KNX ULTIMATE POOL CONTROLLER BY SA 3 1 Electrical connection To enable KNX on LVL connect a Tw
15. he LVL device can communicate also in S Mode You can download ETS files from www vl0 eu download 4 ElGroup Addresses Middle Group Name pP Dynamic Folders 0 LVLO Home screen 4 1 LVLO Dashboard 2 LVLO Service and Settings 10 1 LVLO Dashboard 10 2 LVLO Service and Settings NOTE Pay special attention to the following design when engineering with ETS e Fixed group addresses are defined in the KNX standard for all system functions e Group address are set in the LVL bus devices before they leave the factory e Main group 10 middle group 0 is used for LVL application Home screen functions Contains all major functions and information s to operate pool equipment like light cover auxiliaries and read measured values of water quality and temperature e Main group 10 middle group 1 is used for LVL application Dashboard features Contains all major information s about condition of pool and pool equipment Current state of circuit breakers sensors buffer tank etc e Main group 10 middle group 2 is used for LVL application Setting functions Contains all major functions to control filtration heating cooling details about current LVL and pool conditions Status of circuit breakers pump and valves status sensor alerts etc ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www I
16. isted Pair cable which fulfils the KNX requirements e g YCYM 2x2x0 8 or J Y St Y 2x2x0 8 in TP1 design to the KNX bus connector When installing a standard cable the following conditions apply aor plus Red wire GND Black wire For detailed specification refer to SERVICE MANUAL KNX NOTE Insulated wire cores of sheathed mains cables and KNX TP1 bus cables may be installed next to each other without any clearance space A minimum clearance space of 4 mm must be observed between the insulated wire cores of KNX TP1 bus cables and those of sheathed mains cables Alternatively the wire cores must be provided with an equivalent insulation such as a spacer or insulation sleeving DIN VDE 0110 1 Basic insulation This also applies to wire cores of other cables that are not part of SELV PELV circuits e Terminating resistor is not required 3 2 Configuration This application offers a wide range of setting options in order to execute numerous functions with a KNX pushbutton and controlled KNX devices like touch panels etc Or use pool functions in KNX scenes You will find an overview of all the functions parameters and the related adjustable values in the Group addresses parameters and settings section All 1 bit writable communication objects need to be triggered by 1 bit pulse edge function send telegram 1 following by 0 If pulse edge 1 0 is detected at the input communication object the output reacts to
17. it immediately by changing current state and by sending a status telegram 3 3 KNX network address The network address for a full scale KNX network consists of the area line and device address It reflects the exact position of a bus device in the overall network and is unique within the network NOTE The LVL Ultimate Pool Controller bus device Add Devices t New Dynamic is factory set with the KNX defined individual r EA Devices address 1 1 222 and can be changed only via ISA remote support Please make sure this address is Dynamic Folders not used in KNX network 11 222 LVLO Pool Controller KNX Serial BAOS ETS software used for LVL is present by KNX Bus Access and Object Server in ETS ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www lvl0 eu www lvl0 eu PLUG amp POOL KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 5 of 13 LVLO KNX LVL KNX INTEGRATION MANUAL KNX ULTIMATE POOL CONTROLLER BY SA 4 Engineering with ETS 4 1 KNX Group Addresses Communication between devices in an installation is carried out via group addresses The group addresses are already assigned to the group objects When using the ETS engineering tool e g in systems with third party devices the ETS project database of LVL device must be imported into ETS Selected data points of t
18. may cause damage to the device and result in fire and other hazards Do not connect any external voltage to the inputs Doing so may damage the device s Information for electrically skilled person DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before working on the device disconnect the power supply and cover up live parts in the working environment Safety clearance must be guaranteed in accordance with IEC 60664 1 There must be at least 4 mm between the individual cores of the 230 V supply cable and the KNX line ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www Ivl0 eu www lvl0 eu PLUG amp POOL KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 3 of 13 LVLO ot LVL KNX INTEGRATION MANUAL KNX ULTIMATE POOL CONTROLLER BY SA 2 Overview You can use these instructions to integrate LVL to an existing KNX network and to create visualization of pool equipped with this device LVL communication objects are divided into three groups This division is based on LVL mobile application concept NOTE Group addresses are managed by the manufacturer No of group addresses and associations is 52 WARNING This document does not provide guidance for device commissioning It is necessary to perform complete setup of LVL to ensure that LVL contr
19. oller will work as expected 3 KNX and LVL This document contains specific information applicable to the European Tool Set ETS only S mode communications are not dealt with here The KNX Association has its headquarters in Brussels and is an organization or association of manufacturers which maintains the KNX standard and develops it further The KNX Association supports the trend towards the smart home in which the various building services including lighting heating security systems and other all communicate on the same network Building control technology as provided by KNX is a specialized form of automated process control dedicated to the needs of home and building applications One premise for KNX is to furnish a radically decentralized distributed approach hence the term network The KNX bus enables the LVL to communicate with each other i e to exchange process values and system data in LTE mode LTE Logical Tag Extended LTE mode LTE Logical Tag Extended is characterized by the assignment of zone addresses logical tags to create communications bindings for the exchange of process values Device with the same zone address exchange process values with each other one zone address being capable of transmitting the values of many data points The KNX bus used with LVL is referred to as KNX TP1 A full scale KNX network is a three level structure consisting of one area line from which 15 main lines branch off A
20. ture set point value 10 2 5 LVLO Water Temperature Setpoint Output display of value EIS5 2 Byte 9 001 Floating value C is cyclically send to bus every 600s Floating value C Control hysteresis of the 2 step A A heating cooling controller for water temperature 10 2 6 Saal Setpoint Hysteresis control EIS5 2 Byte 9 001 rom KNX Setting rule Small hysteresis leads to small P uctuations but frequent switching Large hysteresis eads to big fluctuations but infrequent switching LVLO Water Temperature Setpoint Hysteresis K Display actual set point hysteresis temperature weir Output C display of value EISS 2 Byte 2001 Floating value C is cyclically send to bus every 600s ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www Ivl0 eu KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 9 of 13 wwwvw lvi0 eu V LO NX LVL KNX INTEGRATION MANUAL KNX ULTIMATE POOL CONTROLLER BY SA Data Point Name Data Point Type Description Actuator to enable disable water cooling feature Toggle current output status when pulse edge telegram 0 1 will be received on this input Status feedback will be send when output changes state 10 2 8 LVLO Cooling Enable Control Send 1 0 control pulse edge 1 0 1 bit Ww 1 001 LVLO Cooling Status Feedback 0 Dis 10 2 9 sbled 1 Enabled display of status
21. ummarized status feedback object to display sensors status feedback messages Telegram with code is send to bus cyclically every 600s Code explanation A 1 water temperature sensor OK ERR 10 1 9 LVLO Sensors Status Feedback display of value EIS5 2 Byte 8 2 outside temperature sensor OK ERR 4 ext system temperature sensor OK ERR 8 pH electrode OK ERR 16 ORP electrode OK ERR ISA s r o 2015 All rights reserved We reserve the right to change the specification without prior notification Always check for new version of this document www Ivl0 eu KNX integration manual 1 0 Feb 2015 LMO0003 1 0EN 8 of 13 wwwvw lvi0 eu LVLO ULTIMATE POOL CONTROLLER BY SA LVL KNX INTEGRATION MANUAL Data Point Name Data Point Type Description Display days until next regular service set via LVLO 10 1 10 LVLO Regular Service in Day Status Feedback display of value EIS9 4 Byte 14 mobile app Telegram with value cyclically send to bus every 600s pi Display days until next service on pH electrode 10 1 11 se A Sa Sefvicein Day status display of value EIS9 4 Byte 14 calibration replacement set via LVL mobile app Telegram with value cyclically send to bus every 600s ae Display days until next service on Redox electrode 10 1 12 ses aa Flectrode setvice In Day Status display of valu
22. vl0 eu www lvl0 eu PLUG amp POOL KNX integration manual 1 0 Feb 2015 LM0003 1 0EN 6 of 13 LV LO LVL KNX INTEGRATION MANUAL ULTIMATE POOL CONTROLLER BY SA 4 1 1 10 0 x Communication objects for Home screen and statistics section Data Point Name Data Point Type Description Display actual water temperature 10 0 0 LVLO Water Temperature Output C display of value EIS5 2 Byte R 9 001 Floating value C cyclically send to bus Control outside temperature from KNX Floating value C 10 0 1 LVLO Outside temperature Input C control EIS5 2 Byte Ww 9 001 NOTE Setting via LVL mobile app must Settings gt Service gt HEATING gt outside temperature source is set to KNX option Display actual outside temperature 10 0 2 LVLO Outside Temperature Output C display of value EIS5 2 Byte R 9 001 Floating value C cyclically send to bus Actuator to control LIGHT output Toggle current 10 0 3 LVLO Light Control Send 1 0 control pulse edge 1 0 1 bit Ww 1 001 Eee al oe E TA YA _ when output changes state 10 0 4 LVLO Light Status Feedback 1 On 0 Off display of status 1 bit R 1 001 Status feedback of LIGHT output Actuator to control POOL COVER output Pool cover 10 0 5 LVLO Pool Cover Control Open Send 1 0 control pulse edge 1 0 1 bit Ww 1 001 will open when pulse edge 0 1 telegram will be received on this input Actuator to control POOL COVE