Home

TLA5201

image

Contents

1. Setup and Hold Time Selection Range 16 ns range that may be shifted towards the setup region by 0 ns 8 8 ns 4 ns 12 4 ns or 8 ns 16 O ns Setup and hold Window All Channels 1 5 ns typical Minimum Clock Pulse Width 1 5 ns P6434 1 25 ns P6417 P6418 P6419 Demux Channel Selection Channels can be demultiplexed to other channels through user interface with 8 channel granularity Timing Acquisition Characteristics MagniVu Timing Resolution 125 ps 8 GHz storage rate adjustable to 250 ps 500 ps 1 ns and 2 ns MagniVu Timing Record Length 16 Kb per channel with adjustable trigger position Timing Resolution quarter half full channels 500 ps 1 ns 2 ns to 50 ms Timing Record Length quarter half full channels with timestamps and with or without transi tional storage 2 Mb 1 Mb 512 Kb 8 4 2 Mb 32 16 8 Mb per channel Timing Record Length with Glitch Storage Enabled Half of default main record length Channel to Channel Skew 1 ns 900 ps typical Minimum Recognizable Pulse Glitch Width single channel 1 ns P6417 P6418 P6419 1 25 ns P6434 Minimum Detectable Setup Hold Violation 250 ps Minimum Recognizable Multi channel Trigger Event Sample period channel to channel skew 2 Logic Analyzers www tektronix com logic_analyzers Trigger Characteristics Independent Trigger States 16 Maximum Independent If then Clauses
2. 063 3881 xx TLA5000 Recovery Media 063 3884 xx TLA Documentation CD 063 3671 xx TLAS000 Quick Installation Reference 071 1343 xx TLA Quick Start User Manual 071 1575 xx TLA5000 Installation Manual 071 1301 xx Certificate of Traceable Calibration Power Cord Please specify power cord language and service options when ordering Probes are sold separately Instrument options Opt 1C Add iView external oscilloscope cable kit 012 1614 xx Opt 7S Increase to 2 Mb base record length per channel Opt 8S Increase to 8 Mb base record length per channel Recommended Accessories Logic Analyzer Cart LACART K4000 Logic Analyzer Cart Mounting Bracket Kit 407 4996 xx TLA5000 Rackmount Kit 016 1887 xx TLA5000 Wheeled Transport Case 016 1937 xx TLA5000 Service Manual 071 1305 xx Logic Analyzer Probe Selection Guidelines There is a flexible choice of logic analyzer probes available for use with TLA5000 logic analyzers Please see the logic analyzer probe data sheets for more information Service Options Opt C3 Calibration Service 3 Years Opt C5 Calibration Service 5 Years Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 Years with Opt C3 Opt D5 Calibration Data Report 5 Years with Opt C5 Opt R3 Repair Service 3 Years Opt R5 Repair Service 5 Years International Power Plugs AO Nort
3. qualifier channels TLA5204 136 channels 4 are clock and 4 are qualifier channels Time Stamp 51 Bits at 125 ps resolution 3 25 days duration Clocking Acquisition Modes Internal internal 2X internal 4X external external 2X source synchronous 125 ps 8 GHz MagniVu high speed timing is available simultaneous with all modes Input Characteristics with P64xx probe Capacitive Loading lt 0 7 pF typical data clock P6419 1 4 pF typical data 2 pF typical clock P6418 2 pF typical data clock P6417 P6434 Threshold Selection Range From 2 0 V to 4 5 V in 5 mV increments Threshold presets include TTL 1 5 V CMOS 1 65 V ECL 1 3 V PECL 3 7 V LVPECL 2 0 V LVCMOS 1 5 V 0 75 V LYCMOS 1 8 V 0 9 V LVCMOS 2 5 V 1 25 V LVCMOS 3 3 V 1 65 V LVDS 0 V and user defined Threshold Selection Channel Granularity Separate selection for each of the clock qualifier channels and one per group of 16 data channels Threshold Accuracy including probe 100mV Input Voltage Range Operating 2 5 V to 5 0 V Nondestructive 15 V Minimum Input Signal Swing 250mV P6417 P6418 P6419 300mV P6434 Input Signal Minimum Slew Rate 200 mV ns typical State Acquisition Characteristics Maximum State Clock Rate 235 MHz Maximum State Data Rate 470 Mb s State Record Length with Timestamps half full channels 1 Mb 512 Kb 4 2 Mb 16 8 Mb
4. per State 16 Maximum Number of Events per If Then Clause 8 Maximum Number of Actions per If Then Clause 8 Maximum Number of Trigger Events 18 2 counter timers plus any 16 other resources Number of Word Recognizers 16 Number of Transition Recognizers 16 Number of Range Recognizers 4 Number of Counter Timers 2 Trigger Event Types Word group channel transition range anything counter value timer value signal glitch setup and hold violation snapshot Trigger Action Types Trigger main trigger MagniVu store don t store Start store stop store increment counter decrement counter reset counter start timer stop timer reset timer snapshot current sample goto state set clear signal do nothing Trigger Sequence Rate DC to 500 MHz 2 ns Counter Timer Range 51 Bits each gt 50 days at 2 ns Counter Rate DC to 500 MHz 2 ns Timer Clock Rate 500 MHz 2 ns Counter Timer Latency 2 ns Range Recognizers Double bounded can be as wide as any group must be grouped according to specified order of significance Setup and Hold Violation Recognizer Setup Time Range From 8 ns before to 7 5 ns after clock edge in 125 ps increments Setup and hold Violation Recognizer Hold Time Range From 7 5 ns before to 8 ns after clock edge in 125 ps increments Trigger Position Any data sample MagniVu Trigger Position Magn
5. 4 8360 Spain 34 901 988 054 Sweden 020 08 80371 Switzerland 41 52 675 3777 Taiwan 886 2 2722 9622 United Kingdom amp Eire 44 0 1344 392400 USA 1 800 426 2200 For other areas contact Tektronix Inc at 1 503 627 7111 Updated 15 June 2005 Our most up to date product information is available at www tektronix com Product s are manufactured S0 Of in a ae facilities q gg S0 9001 6 Copyright 2005 Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publi cation supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trade marks or registered trademarks of their respective companies 6 05 DV WOW 58W 16733 6 Tektronix Enabling Innovation
6. TLA5000 Series Logic Analyzers gt TLA5201 TLA5202 e TLAS203 TLA5204 TLA5000 Series Logic Analyzers Combine Debug Power with Simplicity and Affordability The affordable TLA5000 Series logic analyzers make high speed timing resolution fast state acquisition long record length and sophisticated triggering available to any digital designer who needs to identify initialization failures operation crashes and intermittent opera tion For first time as well as experienced logic analyzer users the TLA5000 Series is ideal for single bus timing and state analysis An intuitive user interface familiar Windows based desktop and OpenChoice networking and analysis features make the TLA5000 Series logic analyzers easy to network into your design environment 500 ps timing resolution and 32 Mb record length with simultaneous 125 ps MagniVu timing resolution within each acquisition means you can measure digital signal timing on increasingly faster signals with confidence With MagniVu timing resolution find difficult problems such as digital logic errors glitches setup hold violations and crosstalk quickly Use setup hold violation triggering and display to validate setup hold performance of digital devices Today most designs can have both digital and analog anomalies With iView time correlated digital analog view you ll clearly see how analog anomalies are affecting your digital signals right on yo
7. h America power 161 0104 00 A1 Universal EURO power 161 0104 06 A2 United Kingdom power 161 0104 07 A3 Australia power 161 0104 14 A4 240 V North America power 161 0104 08 A5 Switzerland power 161 0167 00 A6 Japan power 161 A005 00 A10 China power 161 0306 00 A99 No power cord or AC adapter Language Options Opt LO English Manuals Opt L5 Japanese Manuals Opt L10 Russian Manuals Opt L99 No Manuals Contact Tektronix ASEAN Australasia Pakistan 65 6356 3900 Austria 41 52 675 3777 Balkan Israel South Africa and other ISE Countries 41 52 675 3777 Belgium O7 81 60166 Brazil amp South America 55 11 3741 8360 Canada 1 800 661 5625 Central East Europe Ukraine and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France amp North Africa 33 0 1 69 86 81 81 Germany 49 221 94 77 400 Hong Kong 852 2585 6688 India 91 80 22275577 Italy 39 02 25086 1 Japan 81 3 6714 3010 Luxembourg 44 0 1344 392400 Mexico Central America amp Caribbean 52 65 56666 333 Middle East Asia and North Africa 41 52 675 3777 The Netherlands O90 02 021797 Norway 800 16098 People s Republic of China 86 10 6235 1230 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 2 528 5299 Russia amp CIS 7 095 775 1064 South Africa 27 11 25
8. iVu position can be set from 0 to 60 centered around the MagniVu trigger Storage Control data qualification Global conditional by state start stop block by trigger action or transitional Force main prefill selec tion available iView Integrated View Capability TDS Oscilloscope Configuration Requirements The iView cable does not connect fully to the TDS1000 2000 Series oscilloscopes without a GPIB extender Tektronix recommends a standard GPIB cable as an extender or order a cable extender National Instruments part number 181638 1 TDS2CMAX Communications Extension Module required for iView capability on any TDS1000 2000 series TDS3GM GPIB RS232 Interface Module required for iView capability on any TDS3000 Series TDS3GV GPIB RS232 VGA Interface Module required for iView capability on any TDS3000B Series Number of TDS Oscilloscopes that Can Be Connected to a TLA System 1 External Oscilloscopes Supported For a complete list of currently supported TDS oscilloscopes please visit our website htto www tektronix com iview TLA Connections USB Trigger In Trigger Out Clock Out TDS Connections GPIB Trigger In Trigger Out Clock In when available Setup iView external oscilloscope wizard automates setup Data Correlation After TDS oscilloscope acquisition is complete data is automatically transferred to the TLA and time correlated with the TLA acquisition data Deske
9. soft high speed mode Serial Interface Port Type Male DB9 Audio Out Port Type Stereo minijack Mic In Port Type Minijack USB Port Four USB 2 0 Symbolic Support Number of Symbols Ranges Unlimited limited only by amount of virtual memory available on TLA Object File Formats Supported IEEE 695 OMF 51 OMF 86 OMF 166 OMF 286 OMF 386 COFF Elf Dwarf 1 and 2 Elf Stabs TSF TSF is a generic ASCII file format documented in the TLA user manual If a format is not listed please contact your local Tektronix representative TLA5000 Series Logic Analyzers gt TLA5201 TLA5202 e TLA5203 TLA5204 External Instrumentation Interfaces System Trigger Output Asserted whenever a system trigger occurs TTL compatible output back terminated into 50 Q BNC type connector System Trigger Input Forces a system trigger triggers all modules when asserted TTL compatible edge sensitive falling edge latched BNC type connector External Signal Output Can be used to drive external circuitry from a module s trigger mechanism TTL compatible output back terminated into 50 Q BNC type connector External Signal Input Can be used to provide an external signal to arm or trigger any or all modules TTL compatible level sensitive BNC type connector Power Voltage range frequency 90 240 VAC at 47 63 Hz Input current 5 A maximum at 90 VAC Power consumption 300 W ma
10. ur logic analyzer display gt Features amp Benefits 500 ps 2 GHz 32 Mb Timing Record Length to Capture Intermittent Events Over a Wide Time Window 125 ps resolution MagniVu Acquisition Simultaneous with Timing or State Acquisition to Find Elusive Timing Problems Quickly Without Double Probing Glitch and Setup Hold Violation Triggering and Display to Find and Display Elusive Hardware Problems 235 MHz State Acquisition Provides Analysis of High speed Synchronous Digital Circuits iView Time correlated Digital analog View to Clearly See How Analog Anomalies Are Affecting Your Digital Signals 34 68 1 02 136 Channel Configurations Offer Flexible Solutions to Fit Any Budget Microsoft Windows XP Professional PC Controller Provides Familiar User Interface with Network Connectivity Remotely Control and Monitor the TLA Over the Network Using Either Hosted Mode or Via Built in Windows XP Remote Desktop gt Applications Digital Hardware Verification and Debug Monitoring and Measurement of Digital Hardware Performance Single Microprocessor or Bus Debug Tektronix Enabling Innovation TLA5000 Series Logic Analyzers gt TLA5201 TLA5202 e TLA5203 TLA5204 gt Characteristics General Number of Channels All channels are acquired including clocks TLA5201 34 channels 2 are clock channels TLA5202 68 channels 4 are clock channels TLA5203 102 channels 4 are clock and 2 are
11. w TDS and TLA data is automatically deskewed and time correlated when using the iView external oscilloscope cable iView External Oscilloscope Cable Length 2 m PC Characteristics Operating System Microsoft Windows XP Professional with Multi Lingual User Interface Pack Processor Intel Celeron 2 0 GHz Chipset Intel 865G DRAM 512 MB SDRAM Sound 16 Bit I O and Mic In port Hard Drive 80 GB Optical Drive Internal 24 10 24 CD RW Floppy Drive Built in 3 5 in 1 44 MB drive Integral Controls Front Panel Display size 10 4 in 26 4 cm diagonal Type Active matrix color TFT LCD with backlight Resolution 1024x768 Colors 256 K Simultaneous Display Capability The front panel and secondary displays can be operated simultaneously using the same resolution The secondary external display can be used simulta neously using an independent resolution Front panel Controls special function knobs for instrument control and mini QWERTY keypad External Peripheral Interfaces External Display Port Type Two female DB15 SVGA External Display Resolution Up to 1600x1200 non interlaced at 16 8 M colors LAN Port Type 10 100Base T RU 45 External Keyboard Port Type PS2 mini DIN External Mouse Port Type PS2 mini DIN Parallel Interface Port Type Female DB25 Parallel Interface Modes Centronics mode EPP Extended Parallel Port ECP Micro
12. ximum Physical Characteristics TLA5000 Dimensions mm in Height 285 11 2 Width 438 17 5 Depth 288 11 35 Weight kg Ib Net without probes 12 26 Shipping typical 18 5 4 Environmental Temperature Operating 5 C to 50 C Nonoperating 20 C to 60 C Humidity 20 to 80 Operating 20 to 80 relative humidity 29 C maximum wet bulb temperature Nonoperating 8 to 80 29 C maximum wet bulb temperature Altitude Operating 1 000 ft to 10 000 ft 305 meters to 3 050 meters Safety UL3111 1 CSA1010 1 EN61010 1 IEC61010 1 Logic Analyzers www tektronix com logic_analyzers 3 TLA5000 Series Logic Analyzers gt TLA5201 TLA5202 e TLA5203 TLA5204 gt Ordering Information TLAS201 34 Channel 2 GHz Timing with 125 ps MagniVu Acquisition 235 MHz State 912 Kb Logic Analyzer TLAS202 68 Channel 2 GHz Timing with 125 ps MagniVu Acquisition 235 MHz State 912 Kb Logic Analyzer TLAS203 102 Channel 2 GHz Timing with 125 ps MagniVu Acquisition 235 MHz State 912 Kb Logic Analyzer TLAS204 136 Channel 2 GHz Timing with 125 ps MagniVu Acquisition 235 MHz State 912 Kb Logic Analyzer All Include Mini Keyboard USB 118 7083 xx Optical Wheel Mouse USB 119 7054 xx Front Panel Cover 200 4651 xx Probe Retainer Bracket 407 4435 xx Accessory Pouch 016 1935 xx Mouse Pad 016 1524 xx TLA5000 Series Product Software CD