Home

Operator`s Manual CFR-4000

image

Contents

1. Note describes information for the installation operation or maintenance of which is important but hazard related if ignored Z N CAUTION Caution indicates the presence of a hazard that could result in minor injury or property damaged if ignored CFR 4000 Operator s Manual 7 2 2 Safety Symbols The International Electro technical Commission IEC has established a set of symbols for medical electronic equipment which classify a connection or warn of any potential hazard The classifications and symbol s are shown below Save these instructions up O and O on power switch represent ON and OFF respectively This symbol identifies a safety note Ensure you understand the function of this control before using it Control function is described in the appropriate User s or Service Manual Identifies the point where the system safety ground is fastened to the chassis Protective earth connected to gt conductive parts of Class equipment for safety purposes Disposal of your old appliance 1 When this crossed out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002 96 EC 2 All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities 3 The correct disposal of your old appliance
2. Load the standard frame which is provided as a standard accessory Press MENU button and select the CALIB gt gt FRAME menu Refer to the section 6 1 for menu operation Press the B button two times to trigger the automatic calibration CFR 4000 Operator s Manual 29 gt It traces the standard frame on both sides twice If it result in any error check if the standard frame is loaded in correct position and try again gt If it fails again contact proper service engineer for maintenance Preparation for the FRAME calibration Standard Frame FRAME calibration menu 11200 E GOTH Meu B Execute CALIB FRAME OK am ZNNorE Calibration results are memorized automatically right after the completion of each calibration Be sure to check the related information before executing the calibration work because you cannot get back the machine to the previous status When a calibration seems not to be done properly try executing the calibration again During the calibration you may press the STOP button to abort the execution 30 CFR 4000 Operator s Manual Pattern Calibration Purpose Detecting the pattern reading position axis and calibrating the size Procedure Load the pattern holder with the standard pattern attached Press MENU button and select the CALIB gt gt PATTERN menu Refer to the section 6 1 for menu operation Press the B button two
3. as an option to provide a means to input job number Variety of DCS communication options are provided to customize it for being com pliant with different types of Lab Management Software such as data format points of data angle type communication speed and more 1 3 Classification Protection against electric shock Class l earthed Installation Category II Pollution Degree 2 6 CFR 4000 Operator s Manual 2 Safety Information 2 1 Introduction Safety is everyone s responsibility The safe use of this equipment is largely dependent upon the installer user operator and maintainer It is imperative that personnel study and become familiar with this entire manual before attempting to install use clean service or adjust this equipment and any associated accessories It is paramount that the instructions contained in this manual are fully under stood and followed to enhance safety to the patient and the user operator It is for this reason that the following safety notices have been placed appropriately within the text of this manual to highlight safety related information or information requiring special emphasis All user operators and maintainers must be familiar with and pay particular attention to all warning and cautions incorporated herein Z WARNING Warning indicates the presence of a hazard that could result in severe personal injury death or substantial property damage if ignored Z N NOTE
4. times to trigger the automatic calibration 2 It traces the standard pattern twice If it result in any error check if the standard pattern is loaded in correct position and try again gt If it fails again contact proper service engineer for maintenance Preparation for the PATTERN calibration Pattern Holder Standard Pattern PATTERN calibration menu LEFT D B Execute IM B CALIB PATTERN o CFR 4000 Operator s Manual 31 Stroke Calibration Purpose Detecting the maximum dimension of possible frame and pattern reading distance Procedure Load the standard frame which is provided as a standard accessory Press MENU button and select the CALIB gt gt STROKE menu gt Refer to the section 6 1 for menu operation Press the B button two times to trigger the automatic calibration If it result in any error check the movement of the stylus in every direction and try again gt If it fails again contact proper service engineer for maintenance Preparation for the STROKE calibration Standard Frame STROKE calibration menu LEFT LI BOTH LI RIGHT B Execute B CALIB STROKE a wma 32 CFR 4000 Operator s Manual Standard Accessory Standard Frame for Frame Reader Calibration Standard Pattern for Frame Reader Calibration Pattern Holder e sim ule idc Rin minim m ch cM Ri in le urn aram Dn i m m M MGR Mn eim m ka
5. 11 Only person who has undergone proper training and instructions are authorized to install use operate and maintain this equipment Keep accompanied manual s or technical materials such as the User s Manual and Service Manual in a place easily accessible at all times for persons operating and maintaining the equipment Do not force cable connections If a cable does not connect easily be sure that the connector plug is appropriate for the receptacle socket If you cause any damage to a cable connector s or receptacle s let the damage s be repaired by an authorized service technician Please do not pull on any cable Always hold on to the plug when disconnecting cables Before every operation visually check the equipment for exterior mechanical damage s and for proper function Do not cover any ventilation grids or slits Immediately turn off and unplug any equipment that gives off smoke sparks strange noises or odors Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions This machine might be impaired if used in a manner not specified by manufacturer and this manual ZA WARNING The equipment should be properly installed and operated based on the instructions on this manual 12 CFR 4000 Operator s Manual LN WARNING Do not disassemble the product without the proper training It may cause the electric shock serio
6. CFR 4000 Operator s Manual 1 Operator s Manual CFR 4000 For Remote Tracing Huvitz Pacing Progress toward People 2 CFR 4000 Operator s Manual IMPORTANT NOTICE This product may malfunction due to electromagnetic waves caused by portable personal telephones transceivers radio controlled toys etc Be sure to avoid having the above objects which affect the normal operation of the product brought near the product The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication HUVITZ assumes no responsibility however for possible errors or omissions or for any consequences resulting from the use of the information contained herein HUVITZ reserves the right to make changes in its products or product specifications at any time without prior notice and is not required to update this documentation to reflect such changes 2005 2013 HUVITZ Co Ltd 689 3 Geumjeong dong Gunpo si Gyeonggi do 435 862 Republic of Korea All rights are reserved Under copyright laws this manual may not be copied in whole or in part without the prior written consent of HUVITZ Co Ltd CFR 4000 Operator s Manual 3 Contents IMPORTANT NOTICE sasssdssvecssatissevsctivassessasvasachuctvavssuntasveseoavavesuetasvesegteavesws LT ANUP OAUCHON E 1 1 System Configuration sscccsssssccsssssrcssscsccssssessssccesssscsesss
7. SUB crossed serial cable Connect a barcode reader to the EDGER2 port barcode reader should have a connector for external power adaptor Connect a power adaptor to the barcode reader Turn on the Frame Reader Cable connection ZNNOTE n case of using a barcode scanner it should be one with external power Source as the frame reader doesn t supply power through the port CFR 4000 Operator s Manual 25 7 3 DCS Options of Frame Reader To access the DCS options in the menu mode at least one of EDGER 1 and EDGER 2 port should be set for DCS Procedure for Menu Execution Press MENU button and select the CONFIG menu gt Refer to the section 6 1 for menu operation Set at least one of EDGER 1 and EDGER 2 port like bellows EDGER 1 2 PC PROTO 1 2 DCS or DCS_Z Change the menu category to DCS if either of the edger port is set for DCS the DCS menu category is activated DCS Parameters Name Description Option List M ID Machine Id 00 99 TIMEOUT Timeout interval for communication 10 90 seconds DATA PT Data points for DCS output 400 500 800 1000 1200 1440 FORMAT Data format for DCS output ASCII ABS ASCII ABS ASCII Absolute BIN ABS BIN ABS Binary Absolute BIN DIF BIN DIF Binary Differential PACKED BIN PACKED BIN Packed Binary ANGLE Angle type for DCS output EVEN UNEVEN 26 CFR 4000 Operator
8. ater splashes dripping water or sprayed water Do not place containers containing fluids liquids or gases on top of any electrical equipment or devices The equipment must be operated only by or under direct supervision of a properly trained and qualified person The service technician of Huvitz or the technician authorized by Huvitz may only carry out modifications of this equipment Customer maintenance of this equipment may only be performed as stated in the User s Manual and Service Manual Any additional maintenance may only be performed by the service technician of Huvitz or the technician authorized by Huvitz The manufacturer is only responsible for effects on safety reliability and performance of this equipment when the following requirements are fulfilled 1 The electrical installation in the respective room corresponds to the specifications stated in this manual and 2 This equipment is used operated and maintained according to this manual and Service Manual The manufacturer is not liable for damage caused by unauthorized tampering with the device s Such tampering will forfeit any right to claim under warranty This equipment may only be used together with accessories supplied by Huvitz If the customer makes use of other accessories use them only if their safe usability under technical aspect has been proved and confirmed by Huvitz or the manufacturer of the accessory CFR 4000 Operator s Manual
9. dn mA m n n la NM EIN M m M Mim m MUR M M MR M M NUR E RCM MTM CM ace 1 Fuse 3 1 5A tinh ara wi a aa n wan aki RR n O d ae KM a a R37 2 Power Cable Frame Reader Serre NN AH MCA UMOR OR RT RR T TOR U UNA URAN kuse rr 1 Option Barcode Scanner Petr TTT TT Ter Cree n A ree re TT eT re reer K O K ee ee eee 1 9 pin Dsub Serial Cable Crossed TIPP 1 Lens Adapter dium din m iu mM aT M M RR MTM M M M M a M M M m CM MTM M M M M B E d m M NN mw C UR RN l M RR MD n 3 Specification Frame Reader Dimension 280 W x 300 D x 230 H mm Tracing System 3D Binocular Weight 8kg Power Supply AC 100 240V 50 60Hz Power Consumption 42W Maximum System Dimension 295
10. eter Value f BEEP O Executed B Parameter B Save amp Return Name R L button changing the value of the executed parameter B button saving the change for the executed parameter and return to the menu CFR 4000 Operator s Manual 21 STOP button canceling the execution and return to the menu Configuration Parameters Name Description Option List BEEP Buzzer activation ON OFF FRAME Default frame material METAL PL HARD PL SOFT EDGER 1 Target device for EDGER 1 port EDGER Selecting NONE disable the port PC NONE PROTO 1 Data communication protocol for HUVITZ EDGER 1 port DCS DOS Z BPS 1 Baud rate for EDGER 1 port 115200 38400 9600 14400 19200 57600 EDGER 2 Target device for EDGER 2 port EDGER Selecting NONE disable the port PC BARCODE NONE PROTO 2 Data communication protocol for EDGER 2 port Same as PROTO 1 BPS 2 Baud rate for EDGER 2 port Same as BPS 1 22 CFR 4000 Operator s Manual 6 2 User Preferences of Frame Reader Refer to 6 1 for operating the Menu Mode User Preference Parameters Name Description Option List ID INFO Product identification VERSION Software version number DBL Bridge size input option for tracing YES single side NO SEMI AT Prompt option SEMI AUTO tracing YES mode NO MINI FR Low speed tracing option for frames YES with mi
11. frame or pattern tracing Scanner ready METAL Tracer beeps and prompts to scan a barcode Scan job no STOP Cancel Scan a barcode and itl display the number for a Job no scanned 123456789012 Second on the screen Frame tracing is automatically started after the job number input The job number is transmitted with the shape data through the EDGER 1 port The job number scanned by the barcode reader is recognized by the target device which is connected to the EDGER 1 port with the protocol DCS or the DCS Z 28 CFR 4000 Operator s Manual 8 System Maintenance 8 1 Automatic Calibration of Frame Reader The Frame Reader requires calibration in following cases Traced shape is off axis Traced shape has smaller or bigger size Stylus tip is not locating the frame groove properly Frame Reader issues height or dimension error for frames or patterns especially when it seems that the mechanical stroke is enough for a frame or a pattern Automatic calibration for frame reader consists of three parts Stroke Frame Pattern In case of any change happened in the stylus do the full calibration in the following Sequence Stroke calibration Frame calibration Pattern calibration Otherwise just perform frame or pattern calibration correspondingly Frame Calibration Purpose Detecting the frame reading position axis and calibrating the size Procedure
12. g not the cord Avoid places where the ambient temperature falls below 10 C or exceeds 40 C for normal operation or below 20 C or exceeds 85 C for transportation and storage Humidity should be maintained between 50 and 80 for normal operation transportation and storage Avoid environments where the equipment is exposed to excessive shocks or vibrations And also the normal operation time is as following Operation time short term operation max 6min 2 4 Safety Precautions This equipment has been developed and tested according to safety standards as well as national and international standards This guarantees a very high degree of safety for this device The legislator expects us inform the user expressively about the safety aspects in dealing with the device The correct handling of this equipment is imperative for its safe operation Therefore please read carefully all instructions before switching on this device For more detailed information please contact our Customer Service Department or one of our authorized representatives This equipment must not be used a in an area that is in danger of explosions 10 CFR 4000 Operator s Manual and b in the presence of flammable explosive or volatile solvent such as alcohol benzene or similar chemicals Do not put or use this device in humid rooms Humidity should be maintained between 50 and 80 for normal operation Do not expose the device to w
13. g Bar Gripper Stylus Rear View Main Switch Power Inlet amp Fuse Holder Interface Terminals EDGER 1 EDGER 2 PC upgrade console EXTRA reserved CFR 4000 Operator s Manual 15 3 2 Standard Accessory e t 4 y a Standard Frame Standard Pattern Pattern Holder amp 16 CFR 4000 Operator s Manual 4 Installation Procedure Install a Frame Reader in a sequence below Remove the shock absorbing material from the package box and pull out the Frame Reader carefully Remove the shock absorbing material from the workspace of Stylus Plug the Power Cable into the power inlet at the back of the product and turn on the power to check the initial operation If the initial operation works properly turn off the instrument Connect Edger and Frame Reader by using a 9 pin D sub Crossed Interface Cable and make sure the connectors are fixed firmly by tightening the scre ws in the cable connector 5 Operation Control Panel Scanner ready METAL Menu Menu Selection CONFIG System Configuration Refer to the section 6 1 Configuration of Frame Reader CALIB Automatic Calibration Refer to the section 7 1 Automatic Calibration of Frame Reader ETC User Preferences Refer to the section 6 2 User Preferences of Frame Reader CFR 4000 Operator s Manual 17 Frame Selection of Frame Material METAL PL HARD Hard Plastic PL SOFT S
14. irable to place the frame so that the center of the frame bridge is aligned with the center mark of the gripping bar CFR 4000 Operator s Manual 19 Press the FRAME button to select a frame material among METAL PL HARD and PL SOFT Press areading button B for both sides R for the right and L for the left Pattern Pattern Tracing Demo Lens Mark the horizontal axis on a pattern or a demo lens and attach a lens adapter on the axis by Pattern Fixing Screw using a blocker Put the blocked pattern to the Pattern Holder Press the FRAME button to select a tracing mode between LO CURV and HI CURV Press areading button R for the right side and L for the left Lens Adapter Center Mark Loading the Pattern Holder 20 CFR 4000 Operator s Manual 6 User Defined Options 6 1 Configuration of Frame Reader Operating the Menu Mode Scanner ready METAL Press the MENU button and then B button to enter the menu mode Press the STOP button over 2 seconds to exit the menu mode Parameter Name LEFT NN GOTH RIGHT Menu Category ALEJ B Name MENU button changing the selection of menu category gt Holding down the button for 2 seconds reverses the selection FRAME button selecting a configuration parameter in a menu category gt Holding down the button for 2 seconds reverse the selection B button executing a selected parameter for change Param
15. ng the Remote Tracing FUN ction cccccsssscsssssssssssssssssssssssssessseees 23 7 1 Interface Specification ecce eee eese eee e eerte eee eeene sees 29 7 2 Connecting to a DCS host eeeeeeeeeeeeeeeeee eee eene eneseeneees 29 4 CFR 4000 Operator s Manual 7 3 DCS Options of Frame Reader ccccccccssssscssssseessscssesssssseeees Z 7 4 Using the Barcode Interface for Inputting Job Number 26 6 System Maintenance eere eese eee eee eene eee einen een ee een netten sete tenes teen 28 8 1 Automatic Calibration of Frame Reader 28 BGUIIOEUPAGUGONSURB ee e eo eee eoe erneuern neon oue rano terno aeterno ee toan une 00 32 oo 0 Coo REESOODUEODUIODUDODODODL DUREE 32 onam Diem M 32 CFR 4000 Operator s Manual 5 1 Introduction 1 1 System Configuration Frame Reader CFR 4000 DCS Host PC 1 2 Main Features Binocular 3 dimensional tracing of frames guaranteeing more precision in frame fitting Tracing of a demo lens or a pattern executes in two different modes HI and LO Especially the HI mode compensates the size by the tilting angle of the demo lens or the pattern SEMI AUTO tracing mode is additionally provided for manual handling of the stylus position into the frame groove especially when the groove is lopsided Barcode scanner interface is supported
16. nimal vertical size NO FPD OFF FPD offset 2 99 2 99 JOB NO Job number reset option Turning on the option keep the last job number even after turning off the power and d the last job number is continued next time FAS it s turned on TRANSMT Data transmission option for when both the edger 1 and 2 ports are turned on AUTO AUTO option transmits automatically USER USER option transmits through user selecting output port EXIT Exits the menu mode CFR 4000 Operator s Manual 23 7 Using the Remote Tracing Function 7 1 Interface Specification Version Information Frame Reader with V1 70 or newer is required Compatible with DCS V3 07 or its compliances RS232C Interface The basic specification of the communication port of the Frame Reader for interfacing PC follows the information below Baud Rate 115200 57600 38400 19200 14400 or 9600 Data Bit 8 Stop Bit 1 Parity None Flow control None Data Format Format ASCII Absolute Binary Absolute Binary Differential Packed Binary Data Points 1440 1200 1000 800 500 400 Radius mode Even Uneven Side Both Right Left Tracing Type Frame Pattern 7 2 Connecting to a DCS host Before connecting the Frame Reader to any PC which is running a lab management Software or a host program on it make it sure to turn the instrument off 24 CFR 4000 Operator s Manual Procedure Connect PC to EDGER1 port with a 9 pin D
17. oft or flexible Plastic Before tracing a frame choose one of the material types Usually this information is used by the edger for such as predefined size adjustment Selection of Pattern Tracing Mode LO CURV 2D Tracing HI CURV 3D Tracing When the Pattern Holder is loaded in the Frame Reader it automatically recognizes the pattern tracing mode Hl CURV mode traces a pattern or a demo lens with size adjustment by the tilted angle of the pattern f the tracing demo lens is curved highly using the HI CURV mode guarantees more precision in size 18 CFR 4000 Operator s Manual LEFT BOTH RIGHT BOTH for tracing both sides of a frame and not for a demo lens R for tracing right side of a frame or a right hand demo lens L for tracing left side of a frame or a left hand demo lens When it s for a frame holding down a tracing button for 2 seconds will executes the SEMI AUTO tracing mode which is to aid tracing a frame with its frame groove lopsided by allowing the operator position the stylus in the center of the groove for normal tracing Operation Tips SEMI AUTO mode has effect on frame tracing only SEMI AUTO mode traces a frame slower than normal tracing mode for safe tracing LEFT RIGHT B Continue SEMI METAL MC STOP DEN Frame Tracing Place a frame between the upper and the lower grippers In case of rather curved frames it s des
18. s Manual FR SIZE Size offset of frame data for DCS i 9 99 9 99 output in terms of circumference PT SIZE Size offset of pattern data for DCS 9 99 9 99 output in terms of circumference MIRROR Mirroring option for DCS output when YES single side is traced NO FRAME Default frame material for a job for DCS output METAL METAL Metal PL HARD PL HARD Hard Plastic PL SOFT PL SOFT Soft Plastic UNDEFIN UNDEFIN Undefined OFF OFF Do not output frame material info 7 4 Using the Barcode Interface for Inputting Job Number CFR 4000 with version 1 68 or newer supports barcode scanning through the EDGER 2 port by setting the EDGER 2 option to BARCODE But it s required to supply power separately to the barcode reader as the EDGER 2 port is not designed to supply power through it This allows it to assign a job number for a new tracing job Go to the CONFIG menu and set the options like below Options for the EDGER 2 port as a barcode interface EDGER 2 BARCODE PROTO 2 N A BPS 2 9600 depending on the setting of a barcode scanner Setup for Barcode Scanner Baud rate 9600 or what else bps that can be matched with the BPS 2 option in the Frame Reader CFR 4000 Operator s Manual 27 Termination code CR lt LF gt or lt CR gt lt LF gt Inputting sequence of Job Number with a barcode scanner Press a button to execute
19. ssesees 1 2 Main Features ccsssssssssssssssssssssssssccssssssssssscsccsssssscssssssssssssssssssees 1 3 ClassifiCatiOn 5 oer eee e eee eee ee e ee eoo e e eo e eo a eoe e e e euo eee eee eae euo 2 5 5 5 5 2 Safety INfOrmaliOnsccrccaccccsscaccecssdaccdsarsaccecsedeccseraceesschacecsdebaccesscaaceesavacceosteas D 2 1 Introduction eee e e eee ecce eese eese eene seen esse sens esee sse sesssseseesss O 2 2 Safety Symbols 1 e eeeeee eee eese esten esee eene eee ono esee ssseseseeseseeees 7 2 3 Environment factors eee ecce eee eee eee eee eren enses esee eens eso senssseesos S 2 4 Safety Precautions ecce e ecce eee eee etes eee eren esses ese esesseseessssseesss D 3 System Configuration eee esee esee eee eene eene eee eennseeeeenneeee LF 3 1 Frame Reader ee eeveee te etn ea een nea eria oua ede vase erae oe eee saea ste essvese 14 3 2 Standard Accessory cease eee ee eee eese ee eene see eese sees eeseseesssseeees LO 4 Installation Procedure eee esee eee eene eee nn eeeennneeeeene LO De 2I EP 1D 6 User Defined Options cccsssscscsssssssssssscsssssscsssscecssssscscssssssssssssssesssesees 20 6 1 Configuration of Frame Reader eeeeeeeeeeeeeeeeeeeeee 20 6 2 User Preferences of Frame Reader eese 22 7 Usi
20. us hurt during the operation or cause the malfunction of the product The product should be properly installed and maintained at the horizontally leveled place Otherwise it may affect the normal operation of the product Do not force on the stylus of frame reader It may cause the malfunction of the product Be sure that the stylus of frame reader is not interfered with the human body or other objects during the operation Otherwise it may cause the hurt or malfunction of the product Z N CAUTION When moving the equipment first fix the stage and check whether the power supply is off In case of setting down the equipment make sure not to be interfered with the obstacles Setting down the product slowly in order to prevent the hurt of human body or damage to the product When moving the equipment make sure the locking device and the screw for the cover are properly tightened In case of packaging the equipment use the recommended packaging material and method in order to prevent the damage during the transportation CFR 4000 Operator s Manual 13 ZN CAUTION Be sure to use the standard accessories or tools provided together with the product for the maintenance Otherwise it may cause the malfunction of the product 14 CFR 4000 Operator s Manual 3 System Configuration 3 1 Frame Reader Front View Workspace for Stylus Display Window Control Panel Grippin
21. will help prevent potential negative consequences for the environment and human health 4 For more detailed information about disposal of your old appliance please contact your city office waste disposal service or the shop where you purchased the product Ix 8 CFR 4000 Operator s Manual 2 3 Environment factors Avoid the following environments for operation or storage Where the equipment is exposed to water vapor Don t operate the equipment with a wet hand Where the temperature changes extremely Operation Temperature 10 40 C Humidity 50 80 Storage Temperature 20 85 C Humidity 50 80 Where the humidity is extremely high or there is a ventilation problem Where equipment is exposed to chemical material or explosive gas Where the equipment is exposed to direct sunlight Where it is near the heat equipment Don t disassemble the product or open We aren t responsible for it for nothing Don t plug the AC power cord into the outlet before the connection between devices of the equipment is completed This can generate the defect CFR 4000 Operator s Manual 9 Where the equipment is subject to excessive shocks or vibrations Be careful not to be inserted dust especially metal Be careful not to close the fan located on the lateral or backside of the equipment Pull out the power cord with holding the plu