Home
P1103FE - Intermatic
Contents
1. Defective timer Memory is full Corrective Action ieee een es Replace battery ne pee ee a Replace timer TE Press to clear memory peed oe EE Press SELECT key and move indicator bar over to AUTO ee Te See above rae Fee EEA Replace timer ee eee eee ee Replace relay
2. These Time Controls in Safety Enclosure are specially suited for installations where the automatic operation of the pool spa filter pump requires occasional interruption suspen sion by someone other than a qualified service professional The unique door within the door design offers three distinct features not found on typical industrial controls First it keeps the wiring compartment locked up acces sible only to the qualified authorized service professional Second it allows safe and convenient operation of the connected equipment by anyone and third in case of emergency it will allow immediate access to the manual operation disconnect of the equipment Other features of the enclosure are the non corrosive nature of the material it is made from the gasketless yet rain tight construction and the self closing design of the access door The electronic timers are designed to control electric appliances and equipment on a 24 hour schedule They can turn ON and OFF the connected load up to eight times daily and repeat the program daily The timers are completely enclosed and a replaceable lithium battery will hold up memory for a minimum of 3 years SPECIFICATIONS Enclosure Indoor Outdoor Type NEMA 3R Non corroding UV resistant thermo plastic featuring 3 point mounting and 5 1 2 3 4 inch concentric knockouts one each side two on the bottom and one on the back Timer Microprocessor based 24 hour clock Power Cons
3. first ON time Press TIMER key once Display will show 1 OFF Repeat previous step to select the desired first OFF time Repeat the entire sequence to complete up to eight total ON OFF times as desired When program ming is done press the CLOCK key then the SELECT key repeatedly until the indicator bar is above the word AUTO To Review Program Press TIMER key repeatedly When done press CLOCK key to return to the time of day To Cancel Change Part of the Program Press TIMER key repeatedly until the particular ON or OFF time appears Set new ON or OFF time See To Set Programs To Override the Automatic Operation one time Press OVR KEY NOTE Timer will resume automatic operation with the next opposite setpoint Ynrermatic Display Reset port to cancel all prior settings ON AUTO OFF Select Key Indicator LED ON when connected to power source and contacts are closed Function Keys To Override Automatic Operation Permanently Press SELECT key to move indicator bar to the desired ON or OFF position Note Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO TROUBLESHOOTING Symptom Possible Cause s Blank Display Timer will not respond to programming Timer will not function Timer is not in auto as programmed Timer is ON at all times Timer is in ON mode Defective timer Defective relay Discharged battery
4. 60 Hz Double Pole Single Throw DPST Contact a qualified service technician including the following edge of pool or spa Electrical Code DANGER TO AVOID RISK OF INJURY d0 not permit children to operate the Control Unit or use the Pool Spa unless they are closely supervised at all times test GROUND FAULT protection regularly If it fails to reset DO NOT USE THE POOL or SPA always disconnect electricity before servicing this control or the equipment connected to it IMPORTANT SAFETY INSTRUCTIONS When installing and operating this Product and other associated equipment basic safety precautions should always be followed 1 This Control must be installed by a qualified electrician according to the National and Local Electrical Codes 2 USE COPPER CONDUCTORS ONLY If applicable install this Control not less than 5 feet 3 meters in Canada from inside 3 Do not exceed the maximum ratings of individual components wiring devices and current carrying capacity of conductors 4 For grounding of the installation refer to Article 250 and 680 of the National Electrical Code or Article 68 or the Canadian 5 This Control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly 6 Always disconnect electricity at main panel before servicing this Control or the equipment connected to it READ FOLLOW AND SAVE THIS INSTRUCTION MANUAL GENERAL INFORMATION
5. FIELD WIRING Model P1102FE Black Red Blue Yellow Note Ground connections are ela a not shown Ld From 240V To 240V Supply Load Model P1103FE Model P1103FE 240 Volt Installation S 2 D xl o D 3 5 z s amp A U U Line Neutral Neutral Load Neutral Linet Line2 Load 1 Load 2 er From 120V To 120V From To 240V Supply Load 120 240V Load Supply ONE YEAR LIMITED WARRANTY lf within the warranty period specified this product fails due to a defect in material or workmanship Intermatic Incorporated will repair or replace it at its sole option the unit free of charge This warranty applies only to the original purchaser and is not transferable This warranty does not apply to a damage caused by accident abuse mishandling dropping acts of God or any negligent use b units which have been subject to unauthor ized repair opened taken apart or otherwise modified c units not used in accordance with instructions d damages exceeding the cost of the product Some states do not allow a limitation of damages so the foregoing limitation may not apply to you This warranty gives you specific legal rights and you may have other rights that vary from state to state INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES ALL IMPLIED WARRANTIES INCLUDING THE WARRANTY OF MERC
6. HANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE This warranty service is available by either a returning the product to the dealer from whom the unit was purchased or b mailing postage prepaid to the nearest authorized service center listed Please be sure to wrap the product securely when mailing to avoid shipping damage This warranty is made by Intermatic Incorporated After Sales Service 7777 Winn Rd Spring Grove IL 60081 9698 815 675 7000 http www intermatic com Because of our commitment to continuing research and improvements Intermatic Incorporated reserves the right to make changes without notice in the specifications and material contained herein and shall not be responsible for any damages direct or consequential caused by reliance on the material presented INTERMATIC INCORPORATED SPRING GROVE IL 60081 9698 http 7 www intermatic com 4 158PB10910 NTERMATIC P1000 SERIES TIME CONTROLS INSTALLATION OPERATION amp SERVICE MANUAL Electronic Time Controls In Outdoor Safety Enclosure SUITABLE FOR POOL SPA EQUIPMENT CONTROL APPLICATIONS ELECTRICAL RATINGS Model P1102FE 20 A Resistive 3 HP 240V 50 60 Hz Double Pole Single Throw DPST Model P1103FE 20 A Resistive 120 240V 10 A Tungsten 120V 1 5 HP 120V 3 HP 240V 50
7. umption 8VA Battery Reserve Type CR2032 1 5V Lithium Battery Life 3 Years Min Minimum Interval 1 Minute of Programming Periods 8 ON 8 OFF INSTALLATION AND INTERNAL WIRING Make sure the intended load is within the capacity of the Timer see ratings on page 1 1 Select the proper location see Important Safety Instructions on page 1 for the proper enclosure of your choice and install it on a vertical surface or other support using hardware suitable for the purpose 2 Prepare the necessary conduit runs as required by the installation layout and pull in the specified conductors 3 Install timer mechanism in enclosure and follow wiring diagram on page 4 make wire connections as shown 4 Turn ON power and test installation using the SELECT button on face of the Timer Replace wiring compartment cover make sure the installation is secure and raintight 5 Set Timer see Operating Instructions on page 3 BLACK RED SETTING OPERATING INSTRUCTIONS Programming Instructions To Set or Change the Time of Day To clear entire memory press key Hold down the CLOCK key while pressing either the HOUR or MINUTE keys Continue pressing until the desired number is shown Then simply lift finger off the CLOCK key to set To Set Program ON OFF times Press TIMER key once to enter into program mode Display will show 1 ON Press the HOUR key and then the MINUTE key to select the desired