Home
to the PDF file.
Contents
1. Para el idioma espa ol navegue hacia www schlage com support Pour la portion fran aise veuillez consulter le site www schlage com support De Ue o 0009200102007429 NE 100001 PER 3 Cao q AO en OO O 275 201201005 REE 920902 190 4 Construction access MOSS a a eo pit io 4 Manual lock programming seccion 5 Credential A de uasteactane 5 Programming legend voices actrices 5 Manual programming commands 6 VOR COS AA e RE OOO 7 TEST lock OPS MO cis ne Acest de A E ACA RAIS Aiet admet sine eee 8 Mechanical ne E O eme en eo lite 8 E1ECIFONIC IS a ne O en no met 8 Normal OCK dee AAPP en 8 E oo A EAEAN 9 Reset to factory OT AS ee a eo ro nain 10 SSS AP SSA 11 To install or replace alkaline batteries 11 Low battery indications eii cra ide 11 Battery failure mode ee ete ticas 11 EED o A e CE SE ne 12 SCNIage PUNON beer Auth AA E ee ou 12 Optional Inside Push Button IPB cccrnidaaic ii a 12 Troubleshooting AA 12 FOG Statements PA es de ie dt nt tee ue deu 12 This product is compliant of UL 294 and ULC 319 standard This products compliance would be invalidated through the use of any add on expansion memory or other module that has not yet been evaluated for compatibility for use with this UL Listed product in accordance with the requirements of the Standards UL 294 and ULC 319 This product has been evaluated for ULC S319 Class I 2 Schlage CO 100 use
2. Cable Cable C ble EQ Conecte el enchufe de la bater a y ajuste como se exhibe Brancher la fiche de la pile et grouper comme illustr Wires Alambres Fils VET fo F WA AMA Changing the Cylinder s Tailpiece Cambiar la pieza posterior del cilindro Remplacement de l embout du cylindre Depress Pin De prensa en el pin De presse la broche 27 Prepare Frame Prepare el marco Pr parez le dormant Wood Madera Bois 16 Tailpiece must be horizontal Debe estar en posici n horizontal Doit tre horizontale A Metal Metal M tal 12 24 CO 28 Install Strike Instalar el cerrojo Future Lever Removal Installez la g che Remoci n futura de la palanca D montage ult rieur du levier sx gt T Q KO j LT 29 After Installing the Lock See the User Guide for Setup and Operation Despu s de instalar la cerradura consulte la Guia del usuario para configuraci n y operaci n Apr s avoir install la serrure consultez le guide d utilisation pour le montage et le fonctionnement Rehanding c Remove Spring Cage Align Arrow with Latch a
3. CO Series for Mortise T CHLAGE Er mr ins P516 267 S ries CO pour la mortaise Instrucciones de instalaci n Installation Instructions Notice d installation Left Hand Shown Right Hand Opposite Se muestra el lado izquierdo para el lado derecho es opuesta Main gauche illustr e main droite en oppos Q Tools Included Herramientas incluidas Outils inclus Prepare Door If Insulator Strip is Present Carefully Remove it See template Si hay una tira aislante ret rela con cuidado Prepare la puerta Si la bande isolante est pr sente l enlever soigneusement Consulte la plantilla Pr parez la porte Consultez le gabarit If Included Install Door Position Switch DPS Verify Tailpiece is Horizontal a Correct a j y Correcto Verifique que la pieza posterior se Correcte puerta DPS encuentre en posici n horizontal Si inclus installez le commutateur de position de porte Si incluido instale el interruptor para posici n de la V rifiez que la queue de p ne soit X Ensure Alignment on Door and Jamb horizontale Y Y Incorrecto r Incorrecte Asegure que la puerta y la jamba est n alineadas Assurez l alignement avec la porte et le montant Install Cylinder and Lever Instale el cilindro y la palanca Keyed Lever Interchangeable Cores Manija con Llave N cleos Intercamb
4. IPB will cause the lock to remain unlocked until the IPB is depressed again Troubleshooting Problem Possible cause Solution The lock does The beeper may be Use manual programming to enable the beeper not function turned off see Disable Enable Beeper on page 7 when a valid PIN credential is entered or the lock beeper does not sound The battery or wired Check that the battery or wired power is power may be connected correctly improperly connected Check that batteries are inserted in the correct The batteries may be polarity inserted with incorrect Replace batteries polarity Check that the optional IPB through door ribbon cable is plugged in correctly if applicable The red wire should be on the left and not pinched in If applicable the IPB the door through door ribbon cable may not be properly plugged in or may have bent pins The batteries may be depleted Check that there are no bent pins on the optional IPB through door cable Refer to the installation instructions that came with the CO 100 lock or this user guide for details on the above mentioned procedures FCC Statements FE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation au Customer Service
5. stop flashing New PIN between each add another PIN OR to finish step Programming Code Wait for e to finish step Programming Code water Change Relock rong rot to stop flashing Time Each button press adds to the total delay time between each Example 1 9 adds a 10 second delay step s to finish 1 Other lights may show before the final confirmation Wait for final confirmation before continuing to the next step 2 Change PIN length is available with firmware version 2 5 0 or higher Deletea PIN IPIN to be deleted Sop Mashing PIN to be deleted nea 6 Schlage CO 100 user guide Manual programming commands Commands are confirmed by five alternating green blinks of the Schlage button Programming mode will time out if no entry is made in 20 25 seconds Timeout is indicated by red blinks of the Schlage button three left and nine right at the same time The right LED on the Schlage button will blink green to indicate an incorrect entry To interpret blink patterns refer to Error codes on page 7 Wait For Press Confirmation Programming Code Wait for Disable Enable 9 9 II to stop flashing Beeper OE Adi o amp to disable to enable etween ea pd step beeper beeper Programming Code Wait for 9 9 Function Change PIN Len to stop flashing Press G 4 5 OR 6 for desired PIN length P each to fini
6. AA Battery Strap Holder amp Cover Screws Battery Strap 2 4B CM 03 042 IT Kit 4AA Battery Cover Screw Battery Cover 1 Must specify Finish Escutcheon Escutcheon Inside 3 This item only available as part of Door Thickness Kit 23599327 without IPB Screws Escutcheon Escutcheon with Escutcheon Inside IPB Screws Escutcheon d Batteries AA F206 488 nas Mounie Mounting Plate Plate Kit Mounting Plate 23599244 Lever Inside 03 030 Spring Cage Sethe Cage Cage aim Ingersoll Rand Security Technologies 7 Zn
7. E Allegion 2014 UY Printed in U S A 1 877 671 7011 www allegion com us ALLEGION P516 270 Rev 03 14 e CO Series Service Manual CO 100 MS KEYPAD ONLY Exterior Number Description Part Number M Number Description Part Number Baseplate Subassembly MS See pg 39 Stand Offs MS MD See pg 41 Lock Case Narrow 1 46 wide 46928818 Baseplate Stand Offs See pg 41 Lock Case 11 4 wide 46928826 Classroom Storeroom 23518392 Cylinder See pg 48 Office Privacy 23518384 Gasket Basepiaie Escutcheon le ER Out oo eee 46929162 Ol Gasket Reader xt yp y _ 44 MD 993 A bl CO 100 23599061 Lever Outside See pg 45 Assembly Spring Cage and Screws Must specify Finish This item only available as part of Exterior Escutcheon Assembly Outside Gasket O Ri ee This item only available as part of Door Thickness Kit Must specify Cylinder Type and Handing Strike Strike See pg 44 Screws Strike If using GD BD Cylinder and Lever preparation use part number 21 27 Armor Front MS ee 23599053 MD Screws Armor Front p9 Spindle See pg 41 Spring Cage Screws Spring Cage See pg 46 e H dR Ingersoll Rand 6 Security Technologies CO Series Service Manual CO 100 MS KEYPAD ONLY Interior Number Description Part Number 8 Number Description Part Number 4AA Battery Holder 35 Spindle See pg 4AA Battery 4
8. acturer s instructions This product has been evaluated for ULC S319 compliance with Duracell Procell PC 1500 AA alkaline batteries and Panasonic CR2025 lithium coin cell For installations requiring ULC S319 these battery models should be used A Plug MUST Be on Right CY MS amp MD Low battery indications Condition Indicator Solution Batteries low After credential PIN is pressed 9 red Replace batteries immediately blinks of Schlage button then normal to avoid battery failure Lock is indicator intended to operate for 500 cycles in low battery condition Battery failure No LED or beeps Replace batteries immediately Valid credentials do not grant access Mechanical override key must be used to unlock the lock Battery failure mode In the event of battery failure the lock will fail As Is lock remains in current state locked or unlocked until batteries are replaced 11 LED reference Schlage button Condition Lights 2 red blinks Valid PIN entered while lock in Freeze mode 12 red blinks indicating lockout Factory default reset One second solid green with one second beep Low battery indicator AA batteries 9 left red blinks Momentary unsecured access 1 green blink then one red blink on relock Optional Inside Push Button IPB Action Lights Office Mode Press IPB to lock 1 red blink Press IPB to unlock 1 green blink 1 Unlocking the lock with the
9. d be smooth and the latch should retract Electronic test 1 Press any number key The lock will beep Use the default PIN 13579 and to verify access Normal lock operation After PIN credentials have been programmed enter a PIN to operate the lock as follows Credential Action Press a valid PIN Green LED will blink and access granted O The key is used as ENTER key for PINs with fewer than six digits Default minimum digits is six 6 PIN length may be manually configured so users do not have to push the key see Change PIN Length2 on page 7 If the PIN credential is entered incorrectly press to start over 8 Schlage CO 100 user guide Lock status reports Follow the steps below to obtain lock status reports O Lock status reporting is available with firmware version 2 5 0 or higher The left and right Schlage button LEDs will blink red once with each button press followed by the status indicator as described below Function Report Indicator Report result Press and hold Wait until only the right Schlage button LED Initiate report EM is on to indicate the lock is in report mode mode and awaiting an entry If no entry is made while pressing 2 9 then timeout will occur in 20 seconds Left LED Solid green excellent Battery status Blinking green good Blinking red low No indicator critical battery Once a status is reported both l
10. eft and right LEDs will light green followed by solid green on the right LED only The right green LED indicates the lock is awaiting another entry Obtain an additional status report as described below or press Ge e to exit report mode Function ms Press Indicator Report result Firmware status status gt B LED blinks green for the version number Decimal point is indicated by one red blink Aaa SAUR Oo 8 Zero is indicated by two red blinks Left LED blinks green for each number PCB serial Each number is separated by two red blinks number Press after two red blinks to display the next number If no entry is made within 20 seconds of the solid green right LED then timeout will occur To exit report mode at any time press Reset to factory defaults All information in the main controller in the lock will be deleted and reset to factory defaults Main controller configurations that will reset to factory default include programming and user codes The door must be locked not toggled open or in the middle of normal access before resetting to factory defaults Follow these steps to reset to factory defaults 1 Remove the top inside cover 2 Remove one battery from the battery pack to disrupt power Wait 5 to 10 seconds for power to run out in the lock 3 Press and hold the Schlage button while reconnecting the battery into the battery pack to resupply power 4 Continue holding the Sch
11. gulos de orientaci n est n alineados Assurez vous du bon alignement des triangles d orientation Stand offs Align with 2 Holes in Mortise Case Los puntos muertos se alinean con 2 orificios en la caja con muesca Le montage vertical s aligne avec les 2 trous situ s dans le bo tier de mortaise Install Plate Instale la placa Installez la plaque TN SE a la a N Wood Madera Bois 16 Metal Metal M tal 12 24 E 72 b AN NUL fe E N P A x a AT N Align as Shown Alinee como se muestra Alignez comme indiqu 20 Test Mechanical Function Pruebe la funci n mec nica Faire un essai de la fonction m canique a Rotate lever down and verify that latch retracts fully a Rote la palanca hacia abajo y verifique que el pestillo se retraiga totalmente a Tournez le levier vers le bas et v rifiez que le loquet se r tracte compl tement b Release lever and verify that latch extends fully b Suelte la palanca y verifique que el pestillo se extienda por completo b Rel cher le levier et v rifiez que le loquet s allonge compl tement 21 Route Wires and Install Inside Escutcheon Dirija los cables e instale la planchuela interior Acheminer les fils et installer l entr e de serrure int rieure Off
12. iables Levier cl Barillets Interchangeables Until Cam Stops Hasta que se detenga la leva Jusqu ce que la came s arr te Align as Shown Alinee como se muestra Check Lever Handing See Rehanding on back page if pin is not toward latch Verifique el lado de la palanca Consulte Cambiar de lado en la ultima p gina si el pin no apunta hacia el cerrojo V rifiez le d placement du levier Consultez le chapitre D placement si la broche n est pas orient e vers le loquet 110 Install Outside Spindle and Standoffs Instale el eje y los distanciadores exteriores Installez l axe de la poign e et les chevilles 1 1 4 Wrench Llave Clef 8 Slide Mortise Lock Into Door Deslice la cerradura de muesca en la puerta Faites glisser la serrure mortaise dans la porte Wrench Llave Clef If Present Route Cable Si hay un cable inst lelo Si pr sent placer le Instale la planchuela exterior y el casquillo Installer la douille et l entr e de serrure ext rieure Note Refer to Sticker for Mortise Rehanding Refi rase a la calcomania para cambiar la muesca de lado Consultez l autocollant pour le d placement de la mortaise Align Triangles Asegure que los tri n
13. ice 40 or Privacy 50 Functions Funciones de oficina 40 o de privacidad 50 Fonction Bureau 40 ou Priv 50 y 40 50 Ribbon Cable Cable de cinta C ble plat VET fo NS Classroom Storeroom 70 Function Funci n sal n de clases almac n 70 Fonction Classe Entrep t 70 70 Battery Cable Cable de bater a C ble de pile VE fe NS Follow Steps Below if 40 or 50 Function Only If Deadbolt Connect Plug If 70 Function Go to Step 22 Si es cerrojo de seguridad conecte la clavija Siga los pasos que se enumeran a continuaci n Dans le cas d un p ne dormant connectez le bouchon si solo desea las funciones 40 o 50 Si se trata de la funcion 70 vaya al paso 22 Pour les fonctions 40 et 50 seulement suivez les tapes ci dessous Pour les fonctions de la 70 passez l tape 22 Install Ribbon Cable and DPS Wires Instale el cable plano y los cables DPS Install Battery Holder and Strap ge posmonde porte Installer le porte piles et la sangle Red Wire MUST Be On Left El cable rojo DEBE estar a f i Plug MUST Be on Right la izquierda Le fil rouge DOIT tre situ A PERE estar a la derecha la gauche La fiche DOIT tre la droite KL je Tuck Cable and Wires as Shown Ajuste el cable y el resto de los mismos como se exhibe Grouper le c ble et les fils comme illustr
14. lage button and wait for two beeps to sound and two green blinks of the Schlage button 5 Release the Schlage button 6 Press and release the Schlage button three 3 times within 10 seconds of the beeps and blinks at step 4 One beep will sound and one red blink will occur with each press 7 The Schlage button will light green for one second and a one second beep will sound indicating that the lock has been reset Ifthe Schlage button is not pressed 3 times within 10 seconds two beeps and two red blinks indicate timeout 8 Replace the top inside cover To test enter 13579 and The Schlage button will blink and the lock will unlock momentarily 10 Schlage CO 100 user guide To install or replace alkaline batteries Changing batteries does not affect any programmed data 1 Remove the battery cover 2 Remove the battery bracket Do not allow the battery pack to hang from the wires 3 Install the new batteries install only new AA Alkaline batteries Make sure the batteries are installed in the correct orientation 4 Reinstall the battery pack and battery bracket 5 Reinstall the battery cover making sure the plug is to the right of the battery pack CY MS and MD locks Be careful not to pinch the battery wires when installing the battery cover CAUTION Danger of explosion if batteries are incorrectly replaced Replace only with new AA alkaline batteries Dispose of used batteries according to the manuf
15. nd Reinstall c Retire la caja de resorte alinee la flecha con el pestillo y reinstale c Retirez la cage ressorts alignez la fl che au loquet et r installez Cambio de lado D placement a If Present Remove USB plug a Si hay un enchufe USB ret relo a Si pr sent retirer la prise USB Use Loctite Utilice Loctite b Remove Reader and Cover From Baseplate Utiliser Loctite b Retire el lector y la cubierta desde la placa base b Retirer le lecteur et le couvercle de la plaque de base d Reinstall Cover and Reader onto Baseplate d Vuelva a instalar la cubierta y el lector en la placa base d Reinstaller le couvercle et le lecteur sur la plaque de base NOTE On Keypad Only Applications Reader is Not A Removable En las aplicaciones solo para teclado el lector no se puede quitar Pour les applications sur clavier uniquement le lecteur n est pas amovible 2012 Schlage Lock Company T X 877 671 7011 dR Ingersoll Rand Printed in U S A Security Technologies P516 267 Rev 01 12 c P516 270 CO 100 Offline lock user guide Instructions for CO Series offline locks
16. r guide Overview The Schlage CO 100 is a keypad only off line electronic lock in the CO Series product line This product is listed for UL294 and ULCS319 Two factory configured functions are available 1 Classroom Storeroom and 2 Office The lock is powered by four 4 AA batteries See Batteries on page 11 for more information e Outside lever is normally locked Inside lever always allows egress Outside Schlage Button Keypad gt a Outside Lever ania Keyway Inside Thumbturn Battery Compartment Optional Inside Push Button Inside Lever CO 100 CY CO 100 MD CO 100 993 CO 100 MS Getting started Follow these steps when setting up a new lock 1 Install the lock See the installation guide that came with the lock or visit www schlage com support for more information 2 Test the lock for proper mechanical and electronic operation See Test lock operation on page 8 for more information 3 When ready to set up for normal use enter a new programming code then program the user credentials See Manual lock programming on page 5 for more information 4 Familiarize yourself with the information in this guide Save this user guide for future reference Construction access mode Construction access mode is used to allow access before the lock has been programmed and for testing TIP purposes Construction access mode i
17. redential code listed in the credential types table Use the same programming code for all locks Three to Six digit code A PIN can be any i of the PIN code types listed in the credential in the facility types table Schlage button 1 Programming codes such as 1 1 1 1 1 or 1 2 3 4 5 can be easily selected by non authorized users and should not be used Manual programming commands Commands are confirmed by five alternating green blinks of the Schlage button Programming mode will time out if no entry is made in 20 25 seconds Timeout is indicated by red blinks of the Schlage button three left and nine right at the same time The right LED on the Schlage button will blink green to indicate an incorrect entry To interpret blink patterns refer to Error codes on page 7 Wait For Press Confirmation Programming Code Wait for Change o m in Programming Code New Programming Code EEHEHE SCH Function New Programming Code step e Programming Code Wait for Add Normal Use PIN gt New PIN tee add another PIN OR to finish Step Programming Code Wait for ee Add Toggle PIN 1 9 1 to stop flashing gt New PIN between each add another PIN OR to finish step Programming Code Wait for G Add Freeze PIN to stop flashing New PIN between each add another PIN OR to finish step Programming Code Wait for 3 aa V to
18. s enabled by If you press the default PIN code default on a new lock and the code is not Offline locks with keypads have a default PIN of 13579 accepted the lock has already and which can be used for installation testing and been programmed construction access If the new PIN is not known or to e To test enter the default PIN 13579 and put the lock back into construction The Schlage button will blink and the lock will access mode reset the lock to unlock factory settings See Reset to The default PIN is automatically deleted when a factory defaults on page 10 for new programming credential is created more information 4 Schlage CO 100 user guide Manual lock programming Left LEDA Right LED Ve DIS Fa 2 4 5 6 N 00 w ES Ne N HE Credential types Credential type Function Description Default PIN Used to program the lock does E homo le se lack Five digit code 97531 and Normal use gt use Unlocks the lock momentarily PIN 3 6 digits 13579 and Toggle Changes the state of the lock PIN 3 6 digits unless in Freeze state Maintains the lock in current state until Freeze PIN is entered again Bye ne alg MU Pase Through Unlocks a lock momentarily PIN 3 6 digits H regardless of state Programming legend Symbol Description TIP Five digit code identical to programming Programming Code c
19. sh p 1 Other lights may show before the final confirmation Wait for final confirmation before continuing to the next step 2 Change PIN length is available with firmware version 2 5 0 or higher Error codes O All error codes are indicated on the Schlage button by a solid red LED and a blinking green LED The number of green blinks indicates the error code Rore d Error code description 1 Computer programming error not complete Too long programming user code entered Programming code must be five 5 digits User code length cannot exceed eight 8 digits Memory full too many codes Delete some codes Programming code cannot be deleted only changed Programming code entries do not match Programming code not changed Invalid command Invalid function code entered 7 Code not found Code too short Programming code length must be five 5 digits User code minimum length is three 3 digits Not a unique code 10 Manual programming not allowed Error code functions have not been verified by Underwriters Laboratories Inc Test lock operation If you encounter problems while performing any of the following tests review the installation guide and correct any problems Mechanical test 1 Rotate the inside lever or depress the push bar to open the door Operation should be smooth and the latch should retract 2 Insert the key into the keyway and rotate the key and the outside lever to open the door Operation shoul
Download Pdf Manuals