Home
Wireless Logger - Cloudfront.net
Contents
1. Fluke s Family of Data Acquisition Products Portable wireless and networked data acquisition Fluke offers three types of data acquisition tools representing three ways to transfer data Getting accurate data where you want it when you want it and in a form that you can work with is a universal goal That s true whether you re designing airplanes or automo biles manufacturing steel or processing chemicals For accurate reliable quick data acquisition Fluke is the common denominator Fluke data acquisition prod ucts feature unique built in universal signal conditioning and a plug in Universal Input Module to provide enormous flexibility This allows you to accurately measure a wide range of parameters simultane ously without the expense or inconvenience of additional equipment Pow erful easy to use Windows based software Supports easy configuration advanced trend analysis and professional quality reporting without any programming The portable Hydra Series transfers data either to internal memory Hydra Data Logger to a removable memory card Hydra Data Bucket or directly to your PC Hydra Data Acquisition Unit The go anywhere Wireless Logger transfers data in real time via a secure RF link to a wireless modem connected to your PC Its wireless design enables it to transmit through buildings walls and floors and makes it conve nient for remote locations It also saves th
2. Wireless Logger for Windows software This easy to use softw are enables you to communicate to Wireless Logger satellites through a single spread spectrum modem S to your PC e Configure remote communica tions with up to 420 channels 20 Wireless Loggers e Site Survey feature helps determine working distance e Set software to alert you to alarm events at your PC NetDAQ Logger software NetDAQ Logger software allows you to easily configure and reconfigure your system and view your data e Set up multiple NetDAQ units up to 20 distributed through out your facility in a grouped mode to create a virtual instrument that synchronizes and directs all data to a single data file e Save valuable disk space by recording only readings out side the range of your normal process limits e Easy network configuration e Advanced triggering modes e File rollover feature automati cally creates a new data file at a specific time or size r lojxj ip jee bog Pole ee p Fjer ra ke w E E m x m eared i te tr i i me CELI LETE i D ffars Hsn ee cei T E Trigger Type Di niama l alel E E amp nite i Heg uniter Chan i atsi l brenga z hen Funriinma ro Lah ika ie l rai al 1 Es L i Se Hee sifi 7 Bisa ag Ersag TH Poppe airn BWA TEST GT i TIJAN All logger softw are features point and click configuration dialogs 10 Trend Link for Fluke softwa
3. This method is kind of like knowing how accurate most of the instru ments will be NetDAQ s 3 Sigma specifications tell you how accurate ALL of the instru ments will be Note Listed specifications are summary in nature Accuracies listed are most favorable within the stated range You may obtain detailed specifications by contacting the offices listed on this page For complete product specifica tions or information on other Fluke products contact your local Fluke Sales representative Customer support Choosing a data acquisition sys tem that meets your specifications is just the first step in making a smart equipment investment You also need to choose a company that can help you get up and running quickly and easily and that will support you throughout the life of the system Fluke has addressed these issues by assembling a wide variety of searvices that are solidly backed by our sales and applica tion support teams world wide service centers and state of the art parts supply system Our offer ings range from comprehensive service programs and technical training to custom programming and system consulting MANAGE Mey sS PS y h O Y FLUKE W 9 S o A lt P YED To mett Y Extended warranty service agreements Warranty extensions are available in some locations to cover neces sary repairs and performance testing including parts labor and return
4. into spreadsheet and word pro cessing programs to generate presentation quality reports Or you can print plots directly for hard copy documentation Alarm shading gives a visual indication of alarm point violation Control bar provides fast easy access to basic chart functions Displays value and time at main cursor intersection Link Atm Tre atm mi SF Hei Ter DEP PC ne a Pa p C wth i Pe ane ar na i Ba P ee Fi i TET os i m j EP Ei Ss ee j S F E i z Son A OCEN PECETE i T j Fim 2 z 1 Tagiem mo an a Gos gE Erg Lai ord Bis Main cursor bar under mouse control Curve status window offers detailed curve information Statistical process control function generates upper low er control limits Notation system attaches your comments as a permanent part of the record Data logging software availability chart Hydra Logger with Trend Link 2635A 902 Wireless Logger 26X5A WL 902 NetDAQ Logger 2640A 911 NetDAQ Logger with Trend Link 2 2640A 912 Trend Link for Fluke 2600A 904 Developer s Tool Box 264XA 903 1 Programs will automatically install the appropriate 16 or 32 bit software based on the resident operating system Windows 3 1 Windows 95 or Windows NT at time of installation Language support for English French Spanish and German 11 Hydra Wireless Logger Specifications e Universal Input Modul
5. 1 mV 0 01 107 to 264V AC 50 or 60 Hz lt 15 watts AC Volts 300 mV to 150 300V 10 uV to 10 mV 0 3 te sk che ce ara i 300ato3Ma Imowwe sources are applied simultaneously the Resistance 300 to 3 MQ 1 mQ to 102 0 015 greater of AC or DC is used At 120V AC Frequency 15 Hz to 1 MHz 0 01 Hz to 100 Hz 0 05 the equivalent DC voltage 14 5V RTD Pt100 200 to 6002C 0 0032C 0 062C Temperature humidity Thermocouples non condensing z 7 5 ee 0358 20 to 28 C lt 90 RH Daa o 100 400 E 40 to 60 C lt 50 RH Storage 40 to 70 C 5 to 95 RH Other Thermocouple types R S B C E N Altitude Operating 2000m Storage 12 200m Electromagnetic Interference EMI Passes FCC EMI Class B Equipment Vfg 243 European Norms EN50081 1 and Model 2645A NetDAQ EN50082 1 CE approved Safety Complies with applicable sections of CE SGD Va tiie ON yea C22 2 No 92 alt standards as noted under Isolation Weight Thermocouples 3 7 kg 100 to 760 Dimensions HxWxD 100 t0 1372C a apa 100 400 Battery life Other Thermocouple types R S B C E N 10 years minimum for real time clock Detailed specifications are available on request Interfaces 1 Total instrument accuracy for 90 days follow ing calibration and ambient temperature range of 18 to 28 C Ethernet Conforms to IEEE 802 3 Includes A D errors linearization conformity initial calibration error isothermality errors reference junction Ether
6. 50V DC or 30V AC rms all channels Isolation 2640A Analog input to analog input and analog input to any digital input meets IEC 1010 1 Category II ANSI ISA 82 01 1994 and CSA C22 2 No 1010 1 92 for 150 300 volts reinforced 2645A Analog input to any digital input meets IEC 1010 Category II ANSI ISA 82 01 1994 and CSA C22 2 No 1010 1 92 for 150 300 volts reinforced Current measurements AC or DC current measurements up to 100 mA may be accomplished using the 2620A 101 10Q Current Shunt Strip Totalizing input DC coupled non isolated max 30V min 4V Max count 4 294 967 295 Minimum signal 2V peak Threshold 1 4V Rate 0 5 kHz debounce off Hysteresis 500 mV Input debouncing None or 1 66 ms Digital inputs Threshold 1 4V Hysteresis 500 mV Maximum input 30V min 4V non isolated Digital master alarm outputs The open collector output lines are non isolated TTL compatible Digital I O and alarm outputs 8 total totalizer 1 Alarm associations Digital I O may be used as a digital input or alarm status output associated with any input channel or channels Trigger input Minimum pulse 5 us Minimum latency 2 ms Repeatability 1 ms Input High 2 0V min 7 0V max Input Low 0 6V min 0 8V max non isolated contact closure and TTL compatible Clock Model 2640A NetDAQ Accurate to within 1 minute month for 0 to 50 C range Power DC Volts 90 mV to 150 300V 0 3 uV to
7. Memory Card 1 MB 263XA 806 Memory Card 2 MB 263XA 807 Memory Card 4 MB RS43 RS 232 cable DB9 to DB9Y Hydra to PC 1 8m 26XXA 600 Hydra Portable Battery Pack 2620A 101 Current Shunt 10Q for 0 to 100 mA Qty 12 MO00 200 634 19 Rack Mount Kit Y8021 Shielded IEEE 488 Cable 1 Meter P N 889589 Service Manual C40 Hydra Carrying Case C44 Transit Case Application software 2635A 901 Hydra Logger 2635A 902 Hydra Logger with Trending 2600A 904 Trend Link for Fluke Wireless Logger RF linked data acquisition eliminates the obstacles to gathering data With the Fluke Wireless Logger you can collect and transmit data via a secure RF link from virtually any location no matter how inaccessible w ithout the expense or hassle of running cable long distances The Wireless Logger satellite consists of a Hydra Data Logger 2625A and a 2 4 GHz wireless modem both housed in a pro tective soft sided carrying case Built in signal conditioning eliminates the need to add additional components for signal or sensor Interfacing Back at the office attach the wireless base station modem to the RS 232 port on your PC install Wireless Logger for Windows software transmit your setup informa tion and you re ready to start collecting data Spread spectrum RF technology clears the way Unlike traditional narrow band RF transmission that is susceptible to electromagnetic interference the
8. Rx 675 mA Thermocouples e Standby lt 40 mA 100 to 760 C 0 19C 0 39 C Q Q Q Operating temperature PA 0 459C Dee aoe 250 fo 00 EN Weight Other Thermocouple types R S B C E N 200 grams Detailed specifications are available on request 1 Total instrument accuracy for 90 days follow ing calibration and ambient temperature range of 18 to 28 C Includes A D errors linearization conformity initial calibration error isothermality errors reference junction conformity and pow er line voltage effects within the range from 90V ACto 264V AC 2 Accuracies for crest factor to 2 0 Hydra 2635A Memory Card capac ity number of scans Memory Card Size Channels in Scan Ooo S ee D wi E 256 KB 8900 4800 2710 36860 19860 11210 74110 39910 22550 149039 80251 45359 NetDAQ Specifications e Universal Input Module Connect 20 analog inputs of virtually any sensor type without external signal conditioning e NetDAQ Interfacing Ports for both 10Base 2 coaxial andl0Base T twisted pair are provided for convenient network cabling RS 232 input for calibration e External Trigger Activate scanning with real world events e Totalizer Count on off events value reported with every scan e Alarm Outputs Flag out of limit conditions to external devices e Power Accepts 107 264V AC or 9 16V DC Can operate from both simultaneously for fail safe pow er operation NetDAQ 2640A 2645A Channel ca
9. spread spectrum technology used in the Wireless Logger is ideal in areas where narrow band equip ment fails It was developed for military communications systems requiring exceptional immunity to electromagnetic interference and high data transmission integrity This means you won t have to worry about motors solenoids walkie talkies and other sources of severe electrical interference interrupting your transmissions It transmits up to 120 meters through walls and floors or up to 300 meters in line of sight appli cations using the modem This technology also allows the Wireless Logger to coexist with other electronic equipment Its power output is lower than cellular phones The spreading techniques and frequency dwell times used by the Wireless Logger modems produce an effective peak power at any frequency that is lower than equivalent narrow band trans mission too low to disrupt or interfere with other electronic instrumentation And it complies with FCC part 15C and does not require an FCC site license The optional 2 4 GHz modem is ETSI certified for operation in most European and many other countries Saves on hazardous duty The Wireless Logger thrives on tough jobs that would put people at risk Whether it s placed at the top of a smokestack or sur rounded by toxic materials high voltage or exhaust fumes the Fluke Wireless Logger is quick to set up and can take the heat Fault tolerance prevents d
10. square root abso lute value and integer functions Math channels have the same alarm capability as analog chan nels This saves the time of per forming separate post calculations on channel data and Is especially helpful for monitoring and alarm ing on real time calculated values such as power flow volumes pressure and more NetDAQ Logger and optional trending software keep you on top of the situation The highly intuitive NetDAQ Logger softw are makes it easy to set up and configure up to 20 NetDAQs Combining NetDAQ Logger softw are with Fluke s optional trending software en ables multiple users to easily monitor processes and import data into spreadsheet programs for further analysis This provides more efficient operation and improved productivity NetDAQ Logger softw are sup ports up to 400 channels and offers a choice of English French Spanish or German during installation Developer s Toolbox for system integration Fluke offers an optional NetDAQ Developer s Toolbox to allow programmers and developers to automate and customize NetDAQ operation using Visual Basic C or C programming languages It includes a set of routines which manipulate NetDAQ measurement hardware through NetDAQ Logger for Windows software allowing you to e Create custom user interfaces for NetDAQ applications e Access real time data and store itin any format such as a custom database e Automatically load di
11. surface freight costs Warranty extensions may not be available in all countries Contact your local Fluke sales office for specific details Service parts and spare parts kits A complete inventory of Fluke replacement parts subassemblies and modules are available Contact your local sales office to find out more about the service programs available in your area or to develop a customer program that suits your needs and budget Fluke Keeping your world up and running Fluke Corporation PO Box 9090 Everett WA USA 98206 9090 Fluke Europe B V PO Box 1186 5602 BD Eindhoven The Netherlands For more information call U S A 800 443 5853 or Fax 425 356 5116 Europe M East 31 0 40 2678 200 or Fax 31 0 40 2678 222 Canada 905 890 7600 or Fax 905 890 6866 Other countries 1 425 356 5500 or Fax 425 356 5116 Web access http www fluke com Email fluke info tc fluke com 1997 Fluke Corporation Specifications subject to change without notice NetDAQ is a trademark of Fluke Corporation Microsoft MS DOS Windows and Windows NT are registered trademarks of Microsoft Corporation Novell is a registered trademark of Novell Inc All rights reserved Printed in the Netherlands 11 97 GO394EEN Rev A
12. Input Module 2620A 101 Current Shunts 10 for 0 to 100 mA Qty 12 Y2641 19 Rack Mount Kit single dual Y2642 Wall Cabinet Mounting Plate Y2644 NEMA 4X IP65 Enclosure C44 Transit Case Data Logging Software Puts your data to work Fluke offers logger softw are for all our data acquisition units These Window s based pro grams turn your PC into a pow erful tool for data acquisition without any programming They support e Configuration of signal conditioning for sensors and signals connected to the Universal Input Module e Data logging functions like intervals triggering alarms Signal scaling and engineer ing units e Easy data exchange by recording data in a file format that s easily imported into other applications such as spreadsheets e Dynamic Data Exchange DDE allows you to establish links for sharing data In real time with Windows based spreadsheet programs such as Microsoft Excel Lotus 1 2 3 and InTouch by WonderWare Data Is updated every second Hydra Logger software Hydra Logger softw are provides easy access to all the powerful features in the Hydra Series e Access one or two Hydra instruments at one time via RS 232 e Establish modem commun ications for remote data acquisition e Convert files to CSV or Trend Link formats e Copy files from a Data Bucket memory card to the PC e Store Data Bucket configura tions on a memory card for easy one step field setup
13. ata loss Each Wireless Logger satellite can store more than 2000 scans in its nonvolatile buffer If your PC goes down during data acquisi tion the Wireless Logger satellite continues to collect measure ments When your PC comes back on line the data collected in the interim can be transferred to your data file automatically Windows based software extends versatile performance Wireless Logger for Windows softw are makes it easy to config ure and communicate with up to 20 Wireless Logger satellites at the same time through a single spread spectrum modem con nected to your PC And you can Share that data with spreadsheet programs In real time Easy to set up and verify A wireless base station that includes Wireless Logger soft ware base station modem and a Wireless Logger satellite are all you need to start collecting data Its unique Site Survey feature makes it easy for one person to Set up satellites and verify com munication between the satellite and the base station Base Station Real time data collection from up to 20 Wireless Logger satellites using the Wireless Logger Base Station 2625A W2 Satellite and 21 to 420 26X5A W2 700 Base Station Wireless Logger features No cables to run or maintain e Up to 300m range e Spread spectrum technology provides exceptional immunity to electromagnetic interference high data transmission integ rity and security e Site Survey capabi
14. e Connect 20 analog inputs of virtually any sensor type without external signal conditioning e Hydra Interfacing Use RS 232 interface to connect to printer PC or modem e External Trigger Activate scanning with real world events e Totalizer Count on off events updated at every scan e Alarm Outputs Flag out of limit conditions to external devices e Power Accepts 90 264V AC or 9 16V DC Can operate from both simultaneously eS a Hydra Series and Wireless Logger Channel capacity Analog inputs 21 Digital 1 0 and alarm outputs 12 total Totalizer 1 Measurement rate Slow 4 Rdgs s nominal Fast 17 Rdgs s nominal 1 5 Rdgs s for V AC Hz and Q inputs nominal Analog to digital converter Dual slope type linear to 17 bits Common mode rejection AC gt 120 dB 50 60 Hz 0 1 max 1 kQ source imbalance dc gt 120 dB Normal mode rejection 53 dB 60 Hz 0 1 47 dB 50 Hz 0 1 Common mode and normal mode voltage maximum 300V DC or V AC rms channels 0 1 11 150V DC or V AC rms all other inputs Isolation Analog input to analog input and analog input to any digital input meets IEC 1010 for 300 150 volts reinforced and ANSI ISA S82 01 1994 and CSA C22 2 for 250 volts single insulation Current measurements AC or DC current measurements up to 100 mA may be accomplished using the 2620A 101 10Q Current Shunt Strip a a ee N a C e an e oe an eS A amp TEUER N EEEO ETEV H
15. e expense of cabling in any location Distributed NetDAQ units plug right into your existing networks to send data directly to a PC This saves the cost of setting up a new network and allows multiple users to simultaneously view data in real time NetDAQ units can also be used as a portable dedicated system connected to a notebook computer for mainte nance product validation research and troubleshooting applications Shared features While their applications vary all three product lines share a number of unique features Unique built in signal condi tioning saves time and money Fluke s data acquisition products are the first to integrate signal conditioning directly into the instrument You can assign any measurement function thermocouple RTD volts frequency or ohms to any or all channels Removable Universal Input Module connects any signal The key to the flexibility of all Fluke data acquisition products is our unique patented Universal Input Module that allows you to connect and measure virtually any electrical or physical parameter Thermocouple reference junction compensation occurs automatically by sensing the temperature of the input module s isothermal block Virtually any combination of sensor or signal lines may be connected to the input module which is plugged into the back of the data acquisition unit You can pre wire extra input modules at each test site and move your data acquisi
16. e same time it is recorded to the memory card Quick setups Simply push a few front panel buttons or load instrument setups from the memory card Fail safe features The Hydra Data Bucket gives advance Indication of a low battery or low memory condition on the memory card Its internal memory buffer continues to store up to 70 scans while the card is removed 2625A Hydra Data Logger A low cost alternative for stand alone monitoring operations Internal memory A built in nonvolatile memory that can store more than 2000 scans Flexible data retrieval The ability to upload stored data or transfer real time data via modem or directly to your PC via the RS 232 port 2620A Hydra Data Acquisition Unit Hydra is ideal for applications that require direct connection to a PC for real time data collection Easy to use front end An RS 232 serial interface makes it easy to connect the Hydra Data Acquisition Unit to a PC or modem for real time data acquisition The 2620A can also be used as a 20 channel panel meter IEEE interface An optional IEEE 488 interface easily allows you to integrate the 2620A with other IEEE 488 instruments and your PC The 2620A delivers workhorse performance for a wide variety of applications such as test and monitoring systems Menu driven software simplifies setup Optional Hydra Logger softw are provides an intuitive graphical interface that makes it even easier to config
17. ed Safety Complies with applicable sections of the IEC1010 ANSI ISA S82 01 1994 CSA C22 2 and CE standards as noted above Weight 3 0 kg Dimensions HxWxD 9 3 cm x 21 6 cm x 31 2 cm Interfaces RS 232 IEEE 488 Optional 2620A only Disables RS 232 interface while in use Hydra 2625A Data Dimensions HxWxD Memory 13 5 cm x 7 5 cm x 1 7 cm Humidity Stores 2 047 scans 20 to 90 non condensing Scan contents ae Certifications Memory life 5 years minimum at Beet y FCC Part 15C No license required Date and time stamp ETSI ETS 300 328 Type Test Europe All defined loa input ch CE EMC EN 55022 and EN 50082 1 efinea analog input cnanne IV EN 60950 values Status of four alarm outputs and Wireless Logger satellites supported eight digital I O Up to 20 Hydra Wireless Logger satel Totalizer count lites can be supported by a Wireless Base Station Wireless Logger Modems 2625A W2 2625A W2 700 2 4 GHz band Power output 100 mW R g FreqUency Hydra Series and Wireless Logger 2 4 2 4835 GHz frequency hopping Range Resolution Accuracy 3 Sigma Radio A DC Volts 90 mV to 150 300V 1 uV to 10 mV 0 018 120m indoors I 2 5 300m line of sight typical AC Volts 300 mV to 150 300V 10 pV to 10 mV 0 13 0 Input voltage Resistance 3002 to 10 MQ 10 mA to 1 KQ 0 013 6 to 15V DC Frequency 15 Hz to 1 MHz 0 01 Hz to 1 kHz 0 05 Input current RTD Pt100 200 to 6002 0 052C
18. fferent setup files e Change Mx B values for each channel on an instrument e Control digital I O channels e Access and control NetDAQ s serial port NetDAQ features e Expandable systems from 20 to 400 channels e High accuracy readings up to 0 01 e Higher throughput to support up to 3000 readings per second e Distributed design enables multiple users equipped with Trend Link softw are to view trend data at the same time e Netw ork flexibility enables you to add to your existing network or set up as a dedicated system m a Ninlee AF i San En T Lig T i r iy ay V OIC WN mA a Ne I 2645A 1000 3 0 mV 300V max for channels 1 11 all others 150V 50 0 72C LJ o A system of up to 400 channels can be configured by daisy chaining multiple NetDAQ units to one PC 2640A NetDAQ Data Acquisition Unit 100 Rdgs s 2645A NetDAQ Data Acquisition Unit 1000 Rdgs s Includes Instrument Universal Input Module 4m Coax cable 50Q terminator Y BNC adapter pow er cable User manual included with NetDAQ Logger softw are Application software 2640A 911 NetDAQ Logger 2640A 912 NetDAQ Logger with Trend Link 2600A 904 Trend Link for Fluke 264XA 903 Developer s Toolbox Options and accessories 264XA 801 Ethernet Card 10Base 2 10Base T PC plug in 264XA 802 Parallel to LAN Adapter 10Base 2 264XA 803 PCMCIA to LAN Adapter 10Base 2 10Base T 2620A 100 Extra Universal
19. lity enables one person to set up satellites and verify communication to the base station e High fault tolerance to continue recording data if PC goes down e Supports up to 20 units for a total of 420 channels RF Modem Spread Spectrum 2 4 GHz 2625A W2 2 4 GHz 2625A W2 700 2 4 GHz Wireless Logger Includes 2625A Hydra Data Logger system one 2 4 GHz FCC ETSI certified wireless modem with power module C42 Carrying Case manual Wireless Logger Base Station Includes One wireless modem 2 4 GHz FCC ETSI certified Wireless Logger for Windows software cables manual Options and accessories 26X5A W2 701 2 4 GHz 26XXA 705 C42 C44 2620A 100 2620A 101 Hydra Wireless Conversion Kit Includes 2 4 GHz wireless modem with power module C42 Carrying Case used to convert 2625A or 2635A to wireless operation Wireless Logger Portable Battery Pack Includes Charger carrying case modem power module connector cable battery 6 5 Ah 12V Wireless Logger Carrying Case Transit Case Extra Universal Input Module Current Shunts 10Q for 0 100 mA Qty 12 NetDAQ Delivers versatile solutions for distrib uted data acquisition Fluke NetDAQ networked data acquisition units are a powerful combination of hardware and softw are seamlessly integrated to deliver your data directly over your network These systems with Trend Link software en able multiple use
20. net standard Compatible with conformity and power line voltage effects within the range from 107V AC to 264V AC Oee and OBa eT andad Ue Accuracies for crest factor to 2 0 TCP IP protocol RS 232C For calibration only The optional NetDAQ Service Manual provides step by step calibration instructions Data buffer memory Each scan consists of computed chan nels time stamp all defined analog input channels the status of the eight digital I O and the totalizer count The number of stored scans varies w ith the number of channels configured ranging from 6400 scans for 1 config ured channel to 1 896 scans for 20 configured channels Fluke measurement specification philosophy The accuracy specifications for Hydra and NetDAQ instruments are calculated conservatively so that they include three standard deviations from the nominal value this is referred to as 3 Sigma Greater than 99 7 of the instruments produced will perform within the error limits Rigorous screening and testing procedures catch and correct the three out of 1000 instruments which could have fallen outside their published specifications Many other products use a root Sum square scheme or only specify the error band within one standard deviation 1 Sigma of nominal This method produces a specification that appears to be more accurate but the resulting typical specifications correctly characterize only 66 of the instruments produced
21. otebook PC for quick easy data collection Add NetDAQ units to your network Adding NetDAQ units directly to your network saves the time and expense of setting up a large network This capability also enables you to provide data ac cess to any or all users on your netw ork NetDAQ Logger softw are works with any Ethernet network that uses TCP IP communications protocol and supports major net work operating systems including Novell Windows for Workgroups Windows NT and Windows 95 Built in 10Base 2 coax and 10Base T twisted pair connec tors give you options for hookup configuration Add a dedicated NetDAQ system to your company network Isolate your data acquisition application from the rest of the network while still allowing mul tiple user viewing This prevents your data acquisition application from being hampered by network operations and protects it from netw ork failure Quick results you can rely on The NetDAQ system supports 3000 readings per second from multiple instruments ensuring high throughput for all units Plus NetDAQ s on board memory provides a data buffer in case netw ork traffic prevents timely delivery of time stamped data to the host PC Computed channels save time In addition to its 20 analog input channels each NetDAQ unit sup ports 10 computed channels It performs custom calculations using addition subtraction multi plication division log natural log exponent
22. pacity Analog inputs 20 Computed channels 10 Computed channels Ten computed channels can be created by processing analog input channels and other computed channels with addition subtraction multiplication division log natural log exponent square root absolute value and integer functions In addition the following predefined selections are available the average of a group of channels the difference between any two channels the differ ence between a channel and a group of averaged channels Measurement rate 2640A Slow 6 Rdgs s nominal Medium 41 50 Hz 48 60 Hz Rdgs s nominal Fast 100 Rdgs s nominal 5 Rdgs s for V AC nominal 140 Rdgs s on 300Q range 37 Rdgs s on 3 MQ range Measurement rate 2645A Slow 45 50 Hz 54 60 Hz Rdgs s nominal Medium 200 Rdgs s nominal Fast 1000 Rdgs s nominal 5 Rdgs s for V AC nominal 370 Rdgs s on 300Q range 44 Rdgs s on 3 MQ range Analog to digital converter 2640A Multi slope type linear to 18 bits 2645A Multi slope type linear to 16 bits NetDAQ rear panel Common mode rejection 2640A AC gt 120 dB 50 60 Hz 10 1 max 1 kQ source imbalance DC gt 120 dB 2645A AC gt 100 dB 50 60 Hz 10 1 max 1 kQ source imbalance DC gt 100 dB Normal mode rejection 50 dB 50 60 Hz 10 1 Common mode and normal mode voltage maximum 2640A 300V DC or V AC rms channels 1 11 150V DC or V AC rms all other channels 2645A
23. re Combine easy analysis and reporting with Trend Link for Fluke software Trend Link for Fluke software is a comprehen sive trend plotting batching and analysis package It combines the look and feel of a chart recorder with the analytical power of your PC Trend Link software is avail able for the full line of Fluke data acquisition instruments Hydra Series Wireless Logger and NetDAQ e Review real time data in the context of historical data for performance or batch comparisons e Compare multiple channels from different time periods e Zoom in on a particular time span for closer analysis e View multiple window s each featuring different process parameters in real time e Calculate basic statistics such as mean and standard devia tion for any trend e Create X bar R charts and X Y scatter diagrams for statistical analysis e Import data directly into Spreadsheet programs from trend plots e Attach text notes to any point on a trace that become part of a permanent record Quickly find specific data Trend Link enables you to quickly scroll through volumes of histori cal and real time data looking for key events or changes in the process When you find what you re looking for you can com pare multiple traces against each other on the same screen or zoom in on a particular point in time Document your results The data and trend plots you generate with Trend Link soft ware can be easily cut and pasted
24. rs to view only the information they need in real time from anywhere on the system View current tempera ture voltage and more on the Same screen at the same time You can also monitor several units simultaneously making it ideal for applications such as equipment monitoring product testing and process validation NetDAQ replaces aging chart recorders and adds future expandability to your measure ment system You can combine from one to twenty NetDAQs into an inte grated NetDAQ system of up to 400 channels Use an existing network or simply connect directly to your PC Two models offer a choice of scan speeds up to 1000 Rdgs s and accuracy up to 0 01 to meet your needs NetDAQ 2640A NetDAQ delivers extremely high accuracy and resolution to provide calibration level performance It measures up to 300V at up to 100 Rdgs s with 0 01 volts DC accuracy and 18 bit resolution scanning 6 to 100 Readings per second NetDAQ 2645A NetDAQ delivers higher speed data acquisition making it ideal for applications that require more dynamic signal capture It directly measures multiple inputs of up to 50V at 1000 Rdgs s with 0 01 volts DC accuracy and 16 bit resolution scanning 48 to 1000 Readings per second NetDAQ fits into your system The versatile NetDAQ system offers flexible options for data distribution Configure a dedicated system Simply daisy chain one or more NetDAQ units to your desktop or n
25. rsal Input Module Connect any sensor type or input signal to any channel internal Signal conditioning automatically sw itches to correct function Hydra Series Portable flexible solutions for stand alone or PC based data acquisition The Hydra Series offers easy portability along with Fluke s built in signal conditioning and Universal Input Module at a price to fit your budget You can easily retrieve data from the Hydra units via the RS 232 interface or through a modem in upload or real time mode Channel information and measurement parameters can be set up directly from the front panel or your PC Three models featuring removable memory card data storage internal memory storage and direct real time data transfer options Should power fail these instruments automatically resume data collection when power is restored Friis a Biei Gite aes 2635A Hydra Data Bucket The ideal choice for gathering and transporting large volumes of data and for working extended periods from remote locations Flexibility The Hydra Data Bucket comes equipped with a 256 KB PCMCIA card and is also available with either a 1 MB 2 MB or 4 MB memory card to suit your data storage needs Data may be up loaded from these cards via the Hydra RS 232 port the optional 263XA 803 memory card drive or from your computer s standard PCMCIA slot Real time data can be simultaneously transferred to a PC at th
26. sed logger software makes instrument configuration and data analysis as easy as a few mouse clicks You can create multiple setup files and save them either to your hard disk or to a memory card for quick reconfig uration You can also save data in a variety of file formats and establish Dynamic Data Exchange DDE links with spreadsheet programs to analyze the data in real time Data acquisition for any application Any data acquisition application that requires high accuracy easy setup portability and convenience calls for Fluke data acquisition Fluke data acquisition products are widely used for e R amp D applications e Environmental testing e Product testing and process validation e Troubleshooting e Manufacturing test systems e And much more Advanced trending capabilities Whether you re gathering data at Optional Trend Link for Fluke softw are enables you to easily access view analyze and com pare tremendous amounts of real time or historical data from any Fluke data acquisition product making paper chart recorders obsolete Trend Link is designed to make it easy to zoom in on data review and compare histori cal data to real time data com pare batch processing operations and automatically view statistics on any channel a high voltage substation in a clean room on a production line or on an automotive test track Fluke data acquisition products can make your job easier Unive
27. tion units from one location to another Rugged design for reliable performance Fluke data acquisition products are designed to stand up to rug ged industrial environments with some models operating from 20 to 60 C A sturdy metal chassis effectively shields against electro magnetic interference so you can maintain high measurement accuracy on low level signals regardless of surrounding noise They are tested to stringent shock and vibration standards and to withstand surges of up to 1500V input on most models All units conform to IEC CSA and CE standards Isolated circuitry for top accuracy Fluke analog measurement circuitry is fully isolated channel to channel input to output and input to ground This isolation supports direct measurement of voltages up to 300V AC rms Scan triggers including interval push button external and alarm triggers scan all defined channels Monitor any channel from the front panel Mx B scaling is available on each channel Selectable measurement rates from 4 Rdgs s up to 1000 Rdgs s depending on model Front panel lockout prevents unauthorized tampering or accidental setup changes Alarms two for each channel can be independently set for high or low sense Real time clock provides precise time stamping of data Closed case calibration for reliability and traceability Operates on AC or DC power Application software No programming required Windows ba
28. ure and access your Hydra unit s powerful fea tures without any programming Easy portability and quick configuration for convenient field use Universal Hydra Series features Signal Review the min max and last readings from the front panel Channel 0 accepts standard test leads from the front panel for quick measurements Monitor a selected channel from the front panel Use the Channel Function to configure measurement type and range for each individual channel Use the Memory Card Drive in 2635A only to store data and instrument configuration on a portable non volatile memory card and transfer collected data to your PC for later analysis Nonvolatile Conditioning Data Storage 2635A Data Bucket Yes 2625A Data Logger Yes 2620A Data Acquisition Unit Yes 2620A 05 Data Acquisition Unit Yes PCMCIA Card RS 232 None IEEE 488 Ordering information 2620A Hydra Data Acquisition Unit 2620A 05 Hydra Data Acquisition Unit with IEEE 488 interface 2625A Hydra Data Logger 2635A Hydra Data Bucket 256 KB memory card 2635A 1MB Hydra Data Bucket 1 MB memory card 2635A 2MB Hydra Data Bucket 2 MB memory card 2635A 4MB Hydra Data Bucket 4 MB memory card Includes Instrument Universal Input Module line cord user manual Starter Softw are DOS Options and accessories 2620A 100 Extra Universal Input Module 263XA 803 External PC Memory Card Drive 263XA 804 Memory Card 256 KB 263XA 805
29. ydra rear panel m E at O Wm Totalizing input DC coupled non isolated max 30V min 4V Max count 65 535 Minimum signal 2V peak Threshold 1 4V Rate 0 5 kHz debounce off Hysteresis 500 mV Input debouncing None or 1 66 ms Digital inputs Threshold 1 4V Hysteresis 500 mV Maximum Input 30V min 4V non isolated Digital alarm outputs The open collector output lines are non isolated TTL compatible Alarms associations Alarm outputs 0 3 are fixed assignments associated to channels 0 3 Alarms for channels 4 19 are mapped to digital I O lines Digital I O may be used as a digital input or alarm status output associated with any input channel or channels Trigger input Minimum pulse 5 us Maximum latency 100 ms Repeatability 1 ms Input High 2 0V min 7 0V max Input Low 0 6V min 0 8V max non isolated contact closure and TTL compatible Clock Accurate to within 1 minute month for 0 to 50 C range Power 90 to 264V AC 50 or 60 Hz lt 10 watts or 9 to 16V DC lt 4 watts If both sources are applied simultaneously the greater of AC or DC is used At 120V AC the equivalent dc voltage 14 5V Temperature humidity non condensing Operating 0 to 28 C lt 90 RH 28 to 40 C lt 75 RH 40 to 60 C lt 50 RH Storage 40 to 75 C 5 to 95 RH Electromagnetic Interference EMI Passes FCC EMI Class B Equipment VDE 0871B and CE EN61010 CE approv
Download Pdf Manuals