Home

2. Annexure-B - Specifications

image

Contents

1. e Both monopolar and bipolar function e Safety circuit secured for patient and operator safety e Outlets for cutting coagulation and bipolar coagulation actuated by foot or hand switch e Two tune audible signals represent CUTTING and COAGULITION procedure e High crest factors provide the T U R e Seven different type of current selected by pushing mode select switch and out puts adjusted by steeples control e Bipolar Coagulation soft standard Coagulation Max 99 watts for large tissue coagulation soft coagulation Max 50 watts for small tissue coagulation Four Modes of monopolar cutting Macro mode e Pure cut 400w a 500 ohms e Blend 230w at 300 ohms e Blend II 180w AT 300 ohms e Blend III 120w at 300 ohms e Two Modes of Monopolar Coagulation 54 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Contact coagulation 100 w at 300 ohms e Spray coagulation 80w at 500 ohms e Different Audible Signals e Different audible signals for cut coagulation and bipolar coagulation e Areas of Use General Surgery Dermatology Endoscopy Vascular Surgery Gynecology Heat Thoracic Surgery ORL ENT Pediatric Surgery Minimally Invasive Surgery MIS Neuro Surgery Plastic Surgery Orthopedics Urology Oral Surgery Trans Urethral Resection T U R e Main Frequency 400 490 KHz 10 400 500KHz 10 e Standard Accessories Color coded double pedal footswitch with cable and connector Silicone rubber patient cable with
2. 50Hz fitted with Indian plug Resettable over current breaker shall be fitted for protection Suitable Servo controlled Stabilizer CVT Online UPS of suitable rating with voltage regulation and spike protection for 30 minutes back up Standards Safety and Training Should be FDA US or European CE approved product Electrical safety conforms to standards for electrical safety IEC 60601 IS 13450 The product shall comply to IEC 60601 2 37 ed1 Medical Electrical Equipment Part 2 37 Particular Requirements for the Safety of Ultrasonic Medical Diagnostic and Monitoring Equipment Type of protection against electric shocks Class Degree of protection against electric shocks for ultrasound probes Type BF For ECG electrodes Type CF Manufacturer Supplier should have ISO certification for quality standards Documentation User manual in English Service manual in English 61 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 List of important spare parts and accessories with their part number and costing available in stock with the supplier e Maintenance and Serviceability Remote Service Network Connectivity Optional Service agreement Online phone Support Clinical application support Warranty 3 years Warranty and 3 years CMC 44 CTG Machine e 7 wide TFT color LCD screen for Fetal Heart Rate Uterine contraction amp fetal movement 62 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e LCD Screen should b
3. C Resolution 0 1 C accolade e Alarm Probe failure Heat failure High and Low Temperature Power failure Electrical supply Power I P to be 180 240 VAC 50Hz fitted with Indian 3 pin plug UPS of suitable rating with voltage regulation and spike protection for 60 Minutes backup e Accessories amp Consumables to be supplied with the machine Mattress 02 two nos Temp Probe Reusable 02 two no s Fuse set 01 one no Monitor tray 01 one no innumerous e Documents Certification Should have safety certificate from a competent authority European CE or FDA US approved product User Technical Maintenance Manual to be supplied in English Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system is required Warranty 3 years Warranty and 3 years CMC 50 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 36 Spot Light with stand Spot Light with Stand e LED light on stand e Power Consumption 40 Watt e Stand with tilting facility e This equipment should be supplied with all necessary fixation accessories Spares Standards European CE EC Marked US FDA ISO certification 37 Stethescope 51 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Stethoscope e Double sided aluminum 1 3 8 diameter with a highly sensitive 1 3 4 diaphragm e Diameter 9 83mm e Supply Voltage V 1 5 10V e Nominal Supply 4 5VDC e Curre
4. Green Armitage 21 cm SS Allis Forcep 20cm SS Babcock forcep 20cm SS Dressing Forcep Tissue 25cm Toothed SS Dressing Forcep Tissue 18cm On Toothed SS 35 Tender No 26 27 28 29 30 31 32 33 34 35 36 37 38 39 29 MPPHSCL 15 16 MCH Equip RC LIST1 Dressing Forcep Tissue 18cm Toothed SS Intestinal Clamps Straight Dry Pattern 23cm SS Intestinal Clamps Curved Dry Pattern 23cm SS Suction Tube Yankauer 23cm Suction Ozzle large Suction Ozzle medium Suction Ozzle small Scissors Straight Mayo Blunt pointed 23 cm SS Scissors Straight Mayo Blunt 23 cm SS Operating scissors straight blunt pointed Mayo 17 cm SS Operating scissors curved blunt pointed Mayo 17 cm SS Retractors Doyens Small SS Retractors Doyens Big SS Needle Holder Mayo Hegar Straight SS 36 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 25 Infusion Pump or Syringe Pump Syringe Infusion Pump meooog 10 0 PAA Description of Function e The Syringe Infusion Pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel It provides accurate and continuous flow rate for precise delivery of V medication in critical medical care Operational Requirements e The syringe pump must be programmable user friendly safe to use and must have battery backup and comprehensive alarm system System Configuration 37 Tender No 29 M
5. Jars 1 x 2 polycarbonate jar Filter Bacterial filter autoclavable reusable Tubing 8mm x2 m Silicone Vacuum Gauge 6 25 cm dia 0 760mmHg calibration 56 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Power 220 V AC 50 60 Hz 90Watt Noise Level 55 dBA 3 Dimension amp Weight 43 x 22 x 37 cm 8 Kg Overflow Safety Mechanical Electronic Acoustic Alarm Tobe supplied with 3 S S cups 40 50 amp 60mmdia Warranty 3 years Warranty and 3 years CMC 41 Weighing machine adult Digital amp Analog e With height meter or without height meter e Analogue and digital e Capacity 150 kg e Readability 100gm e Working temperature 0 50 C e Warranty 3 years Warranty and 3 years CMC 42 Wheel Chair with hand foot and neck rest SS 57 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Wheel Chair with hand foot and neck rest SS e Sturdy heavy duty with brakes e Foldable foot rest e The foot rest should be capable of swinging about its own axis so that it does be a obstruct while moving in or out from the wheelchair e In raised position the foot rest should be at an angle of 1200 e 8 heavy duty wheel e With mega wheel unbreakable e With cushion padded hand rest e Optional Breaking provided leg removable amp adjustable arms removable e Dimensions Overall length 1050mm Overall width 680mm Overall height 910mm Seat height from floor at the front 500mm Seat height
6. Monitor Multi para monitor ECG SPO2 NIBP Non invasive BP and temperature at the head end 41 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Should have TFT LCD display with at least 10 4 inches with 4 wave forms and numeric display simultaneously The waveforms should be user selectable Should be compact amp portable with carrying handle Monitor should have in built Lithium ion type battery for 4 Hrs continuous operations in case of mains failure Should have keys for quick access to main functions Should be able to monitor ECG SpO2 NIBP Respiration Rate ETCO2 upgradable amp Temperature for adult pediatric and neonatal patients 3 or 5 Lead ECG monitoring with lethal arrhythmia recognition capability and ST analysis Respiration amp Apnea alarm Manual Auto and STAT mode for NIBP monitoring and ranges should be 20 to 230 mmHg Pulse Oxymeter SpO2 with Plethysmograph amp Pulse strength indicator with variable pitch with change in SpO2 Upgradable to Side stream Capnography with display of CO2 wave form amp digital values ETCO2 FiCO2 RR Should have separate volume control for beep sound for QRS and alarm sound The display setting should have at least 4 user defined setups variable as per applications for flexible use of the monitor in various clinical environments Monitor should have networking options Should have separate volume control for beep sound for QRS and alarm sound Should provide f
7. detachable connection cable amp rubber strap With holes Reusable Active electrode handles with set of 04 electrodes amp silicone rubber insulated cable Reusable insulated Bipolar Forceps with silicone rubber insulated cable Reusable Monopolar Handle with cable Reusable Twin Complies with Medical Device Directive 93 42 EEC class risk Ila or equivalent Button Handle with cable Electrodes 6 pcs Double Foot switch Single Foot Switch Reusable Return Plate cable Reusable Metal Plate with cable Calibration third party NABL Accredited third party calibration is needed ones in year e Should have safety certificate from a competent authority European CE or FDA US approved product l Manufacturer s quality management system complies with ISO 13485 e Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system is required Warranty 3 years Warranty and 3 years CMC 55 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 40 Ventous Extractor Ventous Extractor Den Ej a a a mN EO u x a T a ee eS e Available in manual and electric modes e Manual 3silicon cups 40mm 50mm and 60mm without valves Autoclavable silicone pressure tube Traction handle Suction pump Fitted glass jar e Electric Housing ABS plastic moulded Capacity 575mm Hg 10 45 Its min Pump type diaphragm pump
8. from floor at the back 450mm Arm height from seat 225mm Seat length 430mm 58 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Seat width between armrest pipes 430mm Back height 380mm Back width at seat level 430 mm Back width at the top 430mm Clearance of foot rest to floor 90 200 mm Back clearance of frame to floor 100mm 10 Meanrim diameter 500mm e Wheel chair should be corrosion resistant e Materials and finishes should be non toxic All surfaces of the wheel chair should be capable of disinfection and cleaning by normal hospital methods e The wheelchair should be subjected to a load of min 75 kg e The chair should move smoothly without any wobbling rocking or rattling J should be ISI certified e Warranty 3 years Warranty and 3 years CMC 43 Colour Doppler Ultrasound System 59 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 System should have following Application with extensive Calculation software package e Obstetrics and Gynaecology e Abdomen e Vascular e Endocavitory application Transvaginal System should have following modes e 2 D Modes e M Modes e Pulse Wave Mode e Colour Flow Mode e Continuous Wave Mode e Colour Power Doppler Imaging e Tissue Harmonic Imaging e Duplex and Triplex mode simultaneity all three modes 2D Colour amp Doppler Modes simultaneously e Anatomical M Mode e Tissue Doppler Imaging Broad Bandwidth Transducers e Convex Array Transduce
9. is required e Warranty 3 years Warranty and 3 years CMC 26 Instrument tray with cover stainless steel 31X19 5X6 5 cm BA IV Stand ss IV Stands equal to total functional beds in ward e Stainless steel e Ahook top 5 legs e Frame mounted on PVC rubber Stumps e Height adjustable up to 150 240 cm e 24 diameter low center of gravity steel base with epoxy finish e 3 premium rubber casters with ball bearings 2 yr warranty e Welded steel base pole with epoxy finish e Slow descending stainless telescoping top pole 99 fully extended 68 compressed 39 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 I V STAND 1 Overall approx size height 136 to 244 cm with adjustable height 2 Main Frame Strong amp Sturdy five legged neatly made base mounted on five 2 5cm dia swiveling ball castors of good quality S S double hocked I V rod amp S S tube spring loaded 28 Jumbo Oxygen Cylinder Oxygen cylinder with instrument set D Type e Chrome Molybdenum Alloy 34 Cr 40 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Capacity 46 7 Ltr water capacity e Working pressure 150kg cm2 at 15 c e Test Pressure 250kg cm2 at 150 c e Wall thickness 5 5 mm min e Gas 02 7000 Itr of 02 e Standard IS 7825 part Il e Valve 1S 3224 e Statutory certifications ISI Standards BMP Certification WHO amp Certified by Dept Explosives GOI e Matching Key cum Spanner to release oxygen 29 Multipara
10. 0sq o Thickness 2 o Cover with venlylized nylon cover o Cover is antibacterial anti static acid resistant waterproof and meets fire regulation cades 16CFR1633 amp 16CFR 1632 33 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Warranty 3 years Warranty and 3 years CMC 24 Hysterectomy Instruments set High quality stainless steel amp corrosive resistant long durability amp reusable rust resistive A Detailed List of required Instruments and Instrument Sets for Maternity Wing Sr No Name of Equipments 1 Cuscos vaginal speculum SS 2 Sims vaginal speculum SS 3 Anterior vaginal wall retractor SS 4 Outlet forcep SS 5 Dressing Drum SS 6 Kidney tray SS 7 Instrument tray with cover stainless steel 31X19 5X6 5 cm 8 Suture cutting scissors SS 34 Tender No 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 29 MPPHSCL 15 16 MCH Equip RC LIST1 Episiotomy scissors SS Devers retractor SS Tooth forcep SS Plane forcep SS Sponge Holding Forceps Forester Straight Serrated 25 cm SS Hysterectomy forcep On toothed WERTHEIM 24 Cm SS Hysterectomy forcep straight toothed WERTHEIM 24 Cm SS Hysterectomy forcep curved MOYNIHAN 23 Cm SS Hysterectomy forcep curved HEANEY 23 Cm SS Halstead Mosquito Forcep 12 5c Curved SS Halstead Mosquito Forcep 12 5c Straight SS Artery Forcep Straight Crile Small 14cm SS Utering Haemostatic forcep
11. Bed SS with Mattress 0 0 0 50 542 0 592 8000 19 Haemoglobinometer 0 0 0 3 0 3000 3003 1000 20 Horizontal Autoclave 250 litres 0 0 0 2 0 0 2 100000 21 Hospital Cot Mother Ward Bed with mattress 0 40 120 250 865 0 1275 6000 22 Hub cutter Electric 0 0 0 20 250 0 270 1200 23 Hydraulic OT Table Major 0 0 0 8 29 0 37 100000 24 Hysterectomy Instruments set 0 0 0 4 24 0 28 30000 25 Infusion Pump or Syringe Pump 20 20 0 20 0 0 60 40000 26 Instrument tray with cover stainless steel 31X19 5X6 5 cm 0 0 0 72 3004 6000 9076 1000 27 IV Stand SS 0 0 0 350 196 4500 5046 1400 28 Jumbo Oxygen Cylinder 25 25 0 0 0 0 50 13000 29 Multipara Monitor 0 6 0 20 0 0 26 71000 30 Normal Delivery Instrument Set 0 0 0 30 884 0 914 10000 31 OT lights ceiling 0 0 0 10 31 0 41 161700 32 Oxygen Hood Neonatal or Infant Size Unbreakable 10 20 0 0 0 0 30 1000 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 33 Patient Stool 0 100 330 2074 0 2504 1000 34 Sims Vaginal Speculum SS 0 0 30 0 0 30 1000 35 Servo Control radiant warmer with oxygen provision 24 0 5 118 0 147 36000 36 Spot Light with Stand 0 0 33 653 1500 2186 1500 37 Stethoscope 0 0 40 272 1500 1812 500 38 Stretcher with stand on wheel 0 0 43 457 1500 2000 3900 39 Surgical Electric Diathermy 0 0 2 24 0 26 50000 40 Ventous Extractor 0 0 2 16 0 18 25000 41 Weighing machine Adult 0 0 20 24 1500 1544 1000 42 Wheel Chair with hand foot
12. H Equip RC LIST1 OT Lights shadow less ceiling mount twin dome 2 A Me gt oS oe e The OT Lights should consist of the following components e BASIC EQUIPMENT Ceiling Mounted Shadow less Operation Theatre LED Lights with Twin Domes on a Single Mount e STANDARD ACCESSORIES Detachable sterilisable focusing handles 2 sets 1 4 e OPTIONAL ACCESSORIES Cost to be quoted separately for each item in the price bid Video camera mount Online Uninterrupted Power Supply Online UPS of a suitable kVA with a backup time of at least 2 hours Spare sterilisable focusing handles e Dual light heads domes each with intensity of at least 100 000 lux at 1m e Colour temperature in the range 4000 to 4500K e Colour Rendition Index at least 93 e 360 deg rotations at each pivot axis and should be stable in any position e Light field diameter should adjustable over a minimum range of 19 cm to 30 cm at 1m 2 6 Working distance of light beam 70 cm to 140 cm for each dome Light field diameter should be constant over this range e Light intensity should be adjustable over a range of at least 30 to 100 e The bulb should be of LED and must be of a single color 44 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Should have adjustable focus system that can be adjusted with a sterilizable and removable handle e LED s must have a single color e Should be upgradeable to install a video camera mount e Pow
13. L 15 16 MCH Equip RC LIST1 Dust Bin Stainless steel Dustbin for patient bed side Colored plastic bins for nursing station Foot operated LID Available in various capacity Patient bedside Nursing station 40 50 Itr 8 Dressing Drum e Light weight high storage capacity e Sizes 9 x9 11 x9 11 x5 and 15 x12 approx e Lid Snaps for on the body 13 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e SS 304 material made up of heavy gauge e Belt fits snugly and uniformly on the body thanks to precision clip which keeps the belt in fair tension e Belt slots and perforations of the body correspond accurately e Custom designed chains for comfortable latching e Configuration design amp material confirms e IS 3831 in all sizes 9 Dressing trolley he e Made of stainless steel with two three shelves e Stainless steel rails to cover three sides of top shelf amp four of bottom e Provided with a bowl and a bucket both made of stainless steel Trolley mounted on four 10 cm swivel castor of which two have breaks As per IS standard 14 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 10 Electric Horizontal Sterilizer with capacity of 10 liters SS Electric Horizontal Cylindrical Instrument Sterilizer 10 Litres e Chamber Size 400 mm diameter x 600 length in inches 16 x 24 Accommodate 2 nos of Drums size 15 x 10 e Chamber Capacity _10Liters Approximately e Cycle Ope
14. PPHSCL 15 16 MCH Equip RC LIST1 e Syringe infusion pump with battery backup alarm and with complete accessories Technical Specifications e Flow rate programmable from 0 1 to 1000 ml hr or more in steps of 0 1 ml hr with user selectable flow set rate option SAVE last infusion rate even when the AC power is switched OFF e Bolus rate must be programmable to 50 1000 ml hr or more with 50ml hr increment with infused volume display Reminder audio after every 1 ml delivered bolus SAVE last Bolus rate even when the AC power is switched OFF e Display of Drug directory of more than 50 drugs customized and adjustable e Keep Vein Open KVO must be available 1 0 ml hr or set rate if lower than 1 0 ml User must have choice to disable KVO whenever desired e Selectable Occlusion pressure trigger levels selectable from 300 500 900 mmHg e Must Work on commonly available 5 10 20 50 60 ml Syringes with accuracy of minimum of 2 or better e Automatic detection of syringe size amp proper fixing Must provide alarm for wrong loading of syringe such as flanges out of slot disengaged plunger unsecured barrel etc e Anti bolus system to reduce pressure on sudden release of occlusion e Must have comprehensive alarm package including Occlusion limit exceed alarm Near end of infusion pre alarm amp alarm Volume limit pre alarm amp alarm KVO rate flow Low battery pre alarm and alarm AC power failure e Comprehensive Training for All S
15. Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Contents Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Contents A List 1 MCH 15 16 Annexure B Sr No Equipment description for Maternal Health amp Child Health Tentative Estimated Page Cost Value Pediatric Maternity annexure Annexure PICU SNCU Ward Wing 2 3 Total in Rs 1 15 15 0 8 53 0 91 20000 2 Bed Side Locker SS with keys 20 20 0 300 1424 0 1764 1940 3 Bed Side Screen SS Godrej Model As per requirement 0 0 0 0 250 0 250 1804 4 Bell From Labor Room 0 2 0 0 0 0 2 300 5 Blood Pressure Apparatus digital 0 0 0 40 272 2000 2312 1400 6 0 0 0 1 0 0 1 90000 7 Bucket Dustbin Steel 0 0 0 20 0 0 20 2000 8 Dressing Drum SS 0 0 0 86 1763 3000 4849 1000 9 Dressing Trolley SS 0 0 0 8 73 0 81 3200 10 Electric Horizontal Sterilizer with capacity of 10 liters SS 0 0 0 5 424 1500 1929 5000 11 Electric Suction Machine 0 0 0 11 48 0 59 8000 12 Electronic Weighing Machine baby weighting 5 6 0 20 80 0 111 1000 13 Emergency Drugs Trolley 10 10 10 0 0 0 30 10000 14 Fire Extinguisher 15 15 0 0 0 0 30 4000 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 15 Examination Table SS with mattress 0 0 0 18 452 1500 1970 10000 16 Foetal Doppler 0 0 0 20 576 1500 2096 3000 17 Foot Operated Suction Machine 0 0 0 1 112 0 113 2500 18 Fowlers
16. and neck rest SS 0 0 32 85 0 117 3500 43 USG machine 0 0 2 13 0 15 500000 44 CTG machine 0 0 0 10 0 10 50000 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 TECHNICAL SPECIFICATIONS FOR MCH EQUIPMENTS Annexure 2 153 DP s 24maternity wards 250 New DP s 6 Medical Colleges Annexure 3 1500 SHC s Note Specifications of all major equipments given below Figures given are only illustrative it does not specify any particular company given in picture to be quoted Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 TECHNICAL SPECIFICATIONS FOR MATERNAL amp CHILD HEALTH EQUIPMENT Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Vertical Electric Autoclave with capacity of 200 litres SS Should have a triple walled construction The working chamber steam jacket outer chamber and the lid should be made of stainless steel Should have water inlet and outlet valves Should have a water level gauge Should have gauges for measuring inner and outer steam pressure Should have an inner temperature indicator Should have automatic pressure control switch safety valve and eject valve Should have joint less silicone gasket Should have automatic low water protection Should be supplied along with bins Should have an ISI mark Should have 1212C working temperature at 15 to 20 psi pressure Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Chamber v
17. ata back and transfer facility e Device characteristics Memory Function Yes Pulse Rate Indicator Yes Display LCD USB port e Measurement Measurement Method Digital Sensor Measurement Accuracy Pressure mmHg 3 mmHg Measurement Range Pressure mmHg Min 40 mmHg Measurement Range Pressure mmHg Max 260 mmHg Measurement Range Pulse beats min Max 160 beats min Measurement Range Pulse beats min Min 40 beats min 10 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Measurement Accuracy Pulse of reading 5 of reading e Power requirements No of Battery 4 Power Source Battery Battery Type AA e Should have safety certificate from a competent authority European CE or FDA US approved product e Manufacturer s quality management system complies with ISO 13485 e Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system is required e Should be provide user manual in English Hindi e Warranty 3 years Warranty 6 Defibrillator Manual AED e Should be USFDA amp European CE IEC Approved e Should have facility for ECG Monitoring Defibrillation External Pacing transcutaneous 11 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Recorder Should be of Rectilinear Biphasic Technology having energy selection upto 1 200 Joules Must be capable of monitoring ECG through ECG cables Multi function electrode
18. con rubber Neck Port adjustment to minimize the wastage of oxygen e Silicon rubber Neck port adjustment ensures can be used Neonate Infant Pediatric patients e Oxygen inlet Port e 02 cell Port temperature port e Overall Hood dimensions o Small 0301 7 0 Lx 7 0 W x 5 4 H o Medium 0300 7 0 Lx 7 0 W x 5 4 H o Large 0305 8 0 L x 8 3 W x 6 9 H o Large Wide Neck 0305W 8 0 L x 8 3 W x 6 9 H o Extra Large 0313 13 0 L x 10 4 W x 8 5 H e Neck opening dimensions o Small 0301 2 5 W x 1 8 H o Medium 0300 3 9 W x 2 5 H o Large 0305 5 0 W x 3 9 H o Large Wide Neck 0305W 5 0 W x 2 9 H o Extra Large 0313 6 3 W x 5 0 H 33 Patient Stool Bed side stool e Frame Work Constructed With MS Steel e Mounted on PVC Rubber Stumps e Size 300 x 300 x 750 mm 47 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Pre treated and epoxy powder coated finishing 34 Sims vaginal speculum SS Vaginal Speculum Sims a complete set of 3 sizes 60x25 30mm 70x30 35mm and 80x35 40mm B5Servo Controlled Radiant Warmer With Oxygen Provision Radiant Warmer 48 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e it should be microprocessor based servo controlled unit that will allow at least two operation modes servo automatic and manual mode e The radiant warmer should have a heating element with power consumption of 80 Watts or less e It should have cal rod tubular q
19. der No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Patient Bed with mattress e Top of the bed made with CRCA sheet e Frame work made with rectangular ms pipe e Strong legs mounted on rubber stumps e Detachable head and foot bows in ms e Pre treaded and epoxy powder coated finishing e Overall size 195 L x 92 W x 60 H cm e Available with mattress e High density foam ILD 48 58 Ibs 50sq e Thickness 6 e Cover with venlylized nylon cover with Zipper e Cover is antibacterial anti static acid resistant waterproof and meets fire regulation cades 16CFR1633 amp 16CFR 1632 22 Hub cutter Electric Hub Cutter e General 29 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 A manually operated needle cutter comprising a cutting device and a needle container The device should be easily portable The device must be safe easy and convenient to use easily cleaned affordable and reliable Needle container should be with optimal storage space to ensure needles or needle residues are stored until the needle container is filled up to its designed maximum fill line Performance Needle size The device should disable wet or dry needles 10 76 mm in length and 18 28 gauge in diameter Needle syringe type The device should disable all ISO compliant syringe needle combinations Cycle time Needle removal or cutting devices should have a maximum cycle time per needle not exceeding 5 seconds Needle entry geometry The ne
20. e tiltable amp rotatable e It should have display modes of Trend mode Number mode amp Graph mode e It should have alarm functions in all movement e t should have facility to increase decrease mute alarm sounds It should have Automatic track amp hold facility e It should have high sensitivity less than 1 MHz FHR upper limit should be 130 240 BPM amp lower limit should be 30 150 BPM e It should have Foetal Heart Rate amp Uterine pressure e t should have automatic and manual foetal movement detection e It should have in built thermal recorder e t should have battery backup e Itshould have a built in memory for 450hrs to save patient graph data e It should have Twin Foetal Monitoring system FHR amp UC probes should have a slot guided connecting mechanism to the main unit e It should have print speed of 1 2 3 cm min e It should have automatic paper feeding function e Should have safety certificate from a competent authority European CE or FDA US approved product e Complies with Medical Device Directive 93 42 EEC class risk Ila or equivalent Manufacturer s quality management system complies with ISO 13485 e Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system is required e Warranty 3 years Warranty and 3 years CMC 63
21. ecting pipes Stainless steel 304 quality Jacket Boiler quality steel plate Stand Mild steel with anticorrosion paint Door jacket Silicon rubber gasket withstand up to 140 deg c Major components e Pressure switch Branded Make e Contractor Branded make Siemens Philips e Steam Tap Spirax Make 121 To 134 degrees and 1 2 to 2 1 kg square cm 27 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Electrical Heater Load e Power Supply e Safety features e Standards e Documentations e Feature m Hospital Cot 18 KW 3 phase 440 V AC 50 hz Supply Door locking facility Low water protection system pressure cut off facility and other safety features European CE approved User manual in English Gauge calibration certificate Warranty certificate and hydraulic test certificate e Should have safety certificate from a competent authority European CE or FDA US approved product e Complies with Medical Device Directive 93 42 EEC class risk Ila or equivalent Manufacturer s quality management system complies with ISO 13485 e Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system is required e Should be provide user manual in English Hindi e Upgradable to HMI PLC Vacuum Pump e Sterilisation time 7 minutes for 134C temperature cycle and 30 Minutes for 121C temperature cycle Warranty 3 years Warranty and 3 years CMC 28 Ten
22. edle aperture must be designed so that the needle can be inserted into the port at any angle lying within a 60 degree cone whose apex is centered on the aperture Complete cutting The cutting blade configuration should ensure that the needle needle hub or syringe nozzle is completely cut or sheared Incomplete shearing or other modes of disabling the needle such as crimping or bending are not allowed Self clearing mechanism The cutting mechanism must be self clearing Syringe or needle remnants remaining in the device must not impair its operation Needle container attachment The needle container if separable must attach securely to the device so that tipping or dropping it does not separate the container from the cutting assembly Attachment of the needle container to and subsequent removal from the cutting assembly should be safe clean and easy There must be no risk of needle stick injury during these operations Operating life Non disposable devices must withstand at least 100 000 cycles of operation and require no major maintenance or user intervention other than cleaning and lubrication no more frequently than once every 10 000 cycles of operation Splatter During or after normal use of the device there should be no detectable contamination Drop test complete device The performance and safety of the cutting assembly must not be compromised by dropping from a height of 1 000mm onto a smooth concrete surface in accordance with the tes
23. er Requirements Voltage 220 20 volts amp frequency 50Hz e The equipment should be of international standards like European CE USFDA BIS or DCGI etc e Power Supply Power input to be 220 240VAC 50Hz fitted with Indian plug Online UPS of appropriate ratings meeting ISI Specifications Input 160 260 V and output 220 240 V and 50 Hz In built rechargeable battery back up that is concealed in the above unit and recharges automatically when connected to AC mains e Standards Safety and Training Should be US FDA or European CE approved product Shall meet the safety requirements as per IEC 60601 2 27 1994 Medical electrical equipment Part 2or equivalent particular requirements for the safety of electrocardiographic monitoring equipment Manufacturer Supplier should have ISO certification for quality standards The service provider should have the necessary equipments recommended by the manufacturer to carry out preventive maintenance test as per guidelines provided in the service maintenance manual Back to back warranty to be taken by the supplier from the principal to supply spares for a minimum period 10 years e Documentation User Manual in English Service manual in English Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out e Warranty The Equipment including all accessorie
24. h at least 1inch in thickness e Mattress cover should be made of fire retardant material e Mattress should be waterproof and easily washable It should be resistant to cleaning with chlorine based solution e The unit should be supplied with 2 two drawers and 1 one IV stand e The minimum diameter of IV stand stainless steel should be 2 5 cm with 4 pegs stainless steel for hanging IV fluids e Cleaning and maintenance of Radiant Warmer and Basinet should be user friendly e The complete unit including the heating element should be European CE 93 42 or FDA US or UL or BIS certified Test certificate for the equipment to be submitted with the tender e Probe length Not less than 5 5 ft e Length of basinet Minimum 680 mm e Width of Basinet Minimum 50 mm e Working level from the ground upto upper level of the mattress Minimum 870 mm 49 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Distance from mattress top and heat source Minimum 850 mm e Diameter of castors for Radiant Warmer and Basinet with brakes locks on front wheels Minimum 75 mm e Length of the IV pole Length and adjustment of the pole e Height adjustment system for Radiant Warmer and Basinet should be accommodated preferable 2 inch e Monitor tray to be supplied with 30 mm X 270 mm e Operating temperature range 20 C to 30 C or wider e Operating humidity range 30 90 RH e Skin temperature Range 32 C to 38 C Accuracy 0 2
25. m Length 200 mm Single use tubes diameter 7x12mm length 180cm Filters Bacterial filters single use Unit presentation Delivered with the following components 1 suction machine and pump 2 one litre bottles or jars with lids 1 safety device 4 overflow spares 2 lid clip spares 2 suction tubes non sterile 2 suction tubes sterile 1 spare fuse 1 user and maintenance manual multilingual Packaging Box 400x400x470mm the following must appear on the pump packaging Manufacturer s name and address Item designation serial number European CE mark and reference number of notifying body Outer packaging Manufacturer s name product name and serial number Other Complies with Medical Device Directive 93 42 EEC class risk Ila or equivalent Manufacturer s quality management system complies with ISO 13485 Warranty 3 years Warranty and 3 years CMC 12 Electronic Weighing Machine baby weighing Weighing machine baby digital Table top light and portable Hygienic easy to clean baby tray Resolution of 5 g optional 1 gm Freeze reading display Zero weight adjustment facility Measurement does not change with position of baby on the pan 18 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Quick clear read outs e Types of scale Spring balance Beam balances and Electronic weighing scales European CE or USFDA certification is required Three years Warranty and 3 years CMC 13 Emergency Dr
26. ndards Graduated square tube 2 pcs Pipette Shali 0 02 ml 6 pcs Filter with rubber cap 2 pcs Spoil with rubber cap 3 pcs Brush1pc Instrument case 1 pc e Specification Pipette error 1 of graduation of 0 02 ml 25 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Standard color error 3 by naked eyes or optical comparison Measurement tube error 3 volume of the tube y 6 mm e Accessories all as required for standard use e Other conditions Equipment must meet ISO or equivalent standards Operating manual in English _ Usable under tropical conditions Warranty min 3 years amp 3 years AMC All surfaces must be cleanable with desinfectional solutions 36 Horizontal Autoclave Horizontal High Pressure Double Door Autoclave electrical Se n f e Chamber Size 500 mm diameter x 1200 depth in inches 20 x 48 26 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Chamber Capacity Cycle Operation mode Door Material of Construction Working Temperature and pressure 250 Liters Approximately Manual operated through multiport Valve to set and select Double door One in front and one in rare side Hinge type with radial locking Chamber Stainless Steel 316 Quality Door Stainless Steel 316 Quality Radial locking arm for door Stainless steel 304 quality Outer cover Stainless steel 304 quality Inbuilt boiler Steam Generator Stainless steel 304 quality Conn
27. ng for All Staff of user department and support services till familiarity with the system is required e Should be provide user manual in English Hindi e Upgradable to HMI PLC Vacuum Pump e Sterilisation time 7 minutes for 134C temperature cycle and 30 Minutes for 121C temperature cycle Warranty 3 years Warranty and 3 years CMC 16 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 n Electric Suction Machine Suction Machine Electrical and Foot Operated Portable suction unit size 38x17x28 5cm weight 5 1kg Technical specifications SUCTION MACHINE AC DC with pump and Food operated Power supply 230 240V 50Hz Vacuum capacity 18 litres mim The membrane vacuum regulator permits accurate vacuum settings 0 to 30 Lits flow rate High Vacuum below 300 mm of Hg amp High Vacuum of 800 mm of Hg Battery backup of 90 minutes minimum Overflow protection ensured Double over flow protection system bottle and pump Working temperature 0 to 45 C Should have safety certificate from a competent authority CE or FDA US approved product 17 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Collector System Bottle or jar 1 litre graduated PSU polysulphone Lid Includes 1 overflow device a 6x10mm diameter conical connector and 2 clips Connection tube Silicone tubing diameter 12x7mm length 25cm and 2 connectors 1 straight and 1 curved 90 Suction tube Reusable silicone tube diameter 7x12m
28. ning External parts and reusable internal parts accessible to the user must be cleanable with standard mild cleaning agents Warranty The device must be warranted to meet all physical and performance requirements defined 31 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Servicing provision on disposable devices The only maintenance required during the design life of the device should be consumable part replacement regular cleaning and lubrication The minimum life cycle of consumable parts should be 25 000 removals cuts or destruction cycles Three additional sets of consumable parts should be provided with the device together with product specific service tools if required e Disposal and recycling Device must be able to be disposed of in the medical waste stream in accordance with the prevailing Bio medical Waste Management Rules prevailing in India Instructions User and maintenance instructions must be available in English and Hindi 23 Hydraulic OT Table Major Hydraulic OT Table Trendelenburg e The table should have minimum 4 sections 32 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e The table should have easily detachable split leg and easily detachable head section e The table top should have a minimum height of 765mm or lesser e The table top should have a minimum vertical stroke of 250mm e Should have sealed hydraulic mechanism to avoid spillage e Should have at least 25 trendelenburg and reve
29. nt Drain 0 5mA max e Signal Noise 40dB min e Sensitivity 65dB 4dB e Output Impedance 1kQ e Frequency Range 30Hz 15000Hz e Around 25 gms weight Turnable diaphragm and a bell e High quality buffed stainless steel snap tight ear tubes e Poly vinyl chloride double lumen tubing around 76 cms in length e Soft sealing ear tips e Manufacturer s quality management system complies with ISO 13485 e Should be provide user manual in English Hindi 52 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 38 Stretcher with stand on wheel Stretcher trolley a e Stretcher made of MS steel supported by tubular frame e Pre treated trolleys epoxy powder coated with frame work made using quality steel tubes e Stretcher trolley mounted on 150mm swiveling castor two equipped with brakes e Available with 50 mm PU form mattress e Two side down fall safety side railing e Size in mm 2030 L x 560 W x 820 H e High density foam mattress ILD 48 58 lbs 50sq e Thickness 2 inch e Cover with venlylized nylon cover with Zipper e Cover is antibacterial anti static acid resistant waterproof and meets fire regulation cades 16CFR1633 amp 16CFR 1632 Warranty 3 years Warranty and 3 years CMC 53 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 39 Surgical Electric Diathermy Surgical Electric Diathermy e Real digital output amp display by microprocessor multi purpose electrosurgical unit
30. oclavable polycarbonate e The following spares per machine are also required Bottles 2 Lids 2 Rubber seal 2 23 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Blades 2 Suction tubing 1 set e Proposal for full warranty up to 1 year from date of installed properly covering on call technical interventions spare parts and travel e Complies with Medical Device Directive 93 42 EEC class risk Ila or equivalent Manufacturer s quality management system complies with ISO 13485 e Warranty 3 years Warranty and 3 years CMC MAS Fowlers Bed SS Fowler Bed with mattress e Bed s frame work of strong and precise steel tubes having H type legs on 10 cms castors two with brakes e Having three sections top of perforated CRCA sheet duly machine press bent with mattress guards e Backrest and knee rest sections maneuvered by two separate screws from foot end e ABS Panels Board IV Rod locations e Size 208 Lx 90 W x 60 H cms e Available with mattress e High density foam ILD 48 58 Ibs 50sq 24 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Thickness 6 inch e Cover with venlylized nylon cover with Zipper e Cover is antibacterial anti static acid resistant waterproof and meets fire regulation cades 16CFR1633 amp 16CFR 1632 e Warranty 3 years Warranty 19 Haemoglobinometer Sahalis Hemoglobinometer e Composition Main unit 1 set Stand for pano parallel non fading 1pc each precision sta
31. of the national standard e Convenience Small size convenient for multi bed monitoring and outside diagnosing e Sensitivity Monitor 12 weeks above unborn foetal heart beat e Economic Adopt with professional recharger battery for effective cost saving and also can use 9 6V disposable batteries e Practical Unique network terminal service can connect central network in hospital through dial up at home more timely reliable and accurate for foetal monitoring tm 100B Foetal Doppler European CE Approved e Manufacturer s quality management system complies with ISO 13485 e Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system is required e Should provide user manual in English Hindi 22 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Warranty 3 years Warranty I Foot Operated Suction Machine Suction Machine Foot Operated e The suction machine should be capable of producing minimum vacuum of 500 approximately mm Hg which should be adjustable and monitored by vacuum gauge of suitable range e The suction capacity should be 10l per minute and can be regulated e It should have two bottles of 10L with synthetic rubber lids e The bottle should be fitted with the arrangement to prevent overflow of fluid e The body material base top and panel should be made up of rust proof and corrosion resistant moulded ABS stainless steel The jar bottle material aut
32. ollowing accessories Reusable adult 3 or 5 lead ECG cable set 2 nos Reusable adult and paediatric SpO2 finger probes 1 each Disposable SpO2 probes for neonatal use 10 no s NIBP cuffs for standard Adult Obese Adult Child and infant all 1 each 42 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Facility for last 24 hours trend review facility amp facility for patient data entry e Equipment performance should not be affected by electromagnetic radiated or conducted through power lines from another device e Should work on 200 240V AC 50Hz with inbuilt rechargeable battery e Should have safety certificate from a competent authority CE or FDA US approved product Copy of the certificate test report shall be produced along with the technical bid e Should be provide user manual in English Hindi e Complies with Medical Device Directive 93 42 EEC class risk Ila or equivalent Manufacturer s quality management system complies with ISO 13485 e Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system is required e Warranty 3 years Warranty and 3 years CMC Delivery Pack Artery Forceps Haemostatic Rankin Crile or Rochester Pean 16cm 2 Cord Cutting Scissors Umbilical Blunt end 16 cm 1 Sponge Holding Forceps Forester Straight serrated 20cm 1 Bowl S S Small 600 750 ml 1 31 OT lights ceiling 43 Tender No 29 MPPHSCL 15 16 MC
33. olume should be approximately 300mm diameter and 500mm depth with minimum 2 bin type e Should be operated in mains 220 240 V ac 50 Hz input power supply Water inlet and outlet pipe should be provided and connections should be done on a turnkey basis Warranty 3 years Warranty and 3 years CMC 2 Bed Side Locker SS with keys Bed Side Medicine Cabinet locker e Metallic with design features for easy cleaning and disinfection e Availability of drawer and a lockable compartment Height 22 44 in 57 cm Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e 3 Privacy Side Screens Movable Size 244cm L X 165 cm H opened 60cm L 165 cm closed Supplied with Rod amp Curtains Special Knockdown construction Frame work made of Epoxy Coated Mild Steel with castors Type 3 amp 4 fold type The curtain fabric should be washable with colour fastness Warranty 3 years Warranty and 3 years CMC Emergency call bell Intelligent call rest technology provided at patient end to ensure patient is attended immediately Patient should be able to call nurse simply by pressing a button provided on bed head unit or hand held extension With easy to install system ISi marked Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 BP Apparatus digital e Pulse Rate Indicator e Memory Recall e One Touch Operation e Digital Sensor e Auto Shut off Function e Clinically Proven e 4AA reachable Battery Operated e Should have d
34. r Frequency 2 5 MHz e Intracavitatory Transducer Frequency 4 10 MHz e Linear Transducer 5 12 MHz e Scan depth should be 28cm or more for convex transducer e System should have Dual amp Quad split display e Duplex for simultaneous B mode amp Spectral Doppler e Facility of Full screen imaging e The system should support real time acquisition and display of two image planes simultaneously with colour e Facility for Zoom real time and frozen image e One touch image optimization and automatic real time Doppler tracing 60 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 High resolution flicker free antiglare _LCD LED medical grade flat panel display of 15 or more with maximum viewing angle Alpha numeric key board with track ball Complete package for measurement amp calculation for all applications mentioned at Sr no 1 with digital calipers for distance area volume circumference amp Doppler wave form parameter measurement etc PW Doppler analysis in Auto amp Manual mode Pan zoom feature for real time amp frozen Images Image Management Facility Inbuilt hard disk with memory of minimum 500 GB Direct storage of Images amp Cine loops in Hard disk Patient ID display Environmental factors The unit shall be capable of operating continuously in ambient temperature of 30 deg C and relative humidity of 80 Pre Requisites should be clearly spelt out in terms of room requirements Power Supply Power input to be 180 240VAC
35. ration Manual operated through multiport Valve to set and select mode e Door Single door Hinge type with radial locking e FEEDWATER PUMP To draw water automatically when needed in the inbuilt boiler e Material of Chamber Stainless Steel 316 Quality Tun Door Stainless Steel 316 Quality Radial locking arm for door Stainless steel 304 quality Outer cover Stainless steel 304 quality Inbuilt boiler Steam Generator Stainless steel 304 quality Connecting pipes Stainless steel 304 quality Jacket Boiler quality steel plate Stand Mild steel with anticorrosion paint Door jacket Silicon rubber gasket withstand up to 140 deg c e Working 121 degrees and 1 2 kg square cm Temperature and 15 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 pressure e Electrical Heater Load e Power Supply e Safety features e Documentations e Features 6 KW 3 phase 440 V AC 50 hz Supply Door locking facility Low water protection system pressure cut off facility and other safety features User manual in English Gauge calibration certificate Warranty certificate and hydraulic test certificate e The equipment should have ISI mark on quality e Should have safety certificate from a competent authority European CE or FDA US approved product e Complies with Medical Device Directive 93 42 EEC class risk Ila or equivalent Manufacturer s quality management system complies with ISO 13485 e Demonstration Comprehensive Traini
36. rse trendelenburg e Should have at least 20 lateral tilt movement e Should have at least 80 back up movement with gas spring mechanism e The head section should have up and down movement e The leg section should have 90 down movement and should move side wards to a minimum of 90 degree e The table should have a heavy and sturdy base and compact to provide adequate foot room for the operating team e The table should be mounted on heavy duty casters which offer enhanced weight bearing capacity and free mobility e The table should have a single lever foot operated brake pedal e Should have a minimum patient weight bearing capacity of 100 Kgs e Base should be made of cast iron and all other parts and accessories should be completely made of Stainless Steel 304 grade except the cushion gas spring and hydraulic system which should be made of any non resting metals like brass etc e The table should be supplied with the following accessories Mattress for the complete table top in sections 1 set A pair of arm boards with pad and fixing clamp 1 A pair of padded shoulder support with clamps 1 A pair of padded lateral support with clamps 1 A pair of leg crutches with clamps 1 Anesthetic screen frame with clamp 1 Patient restraint strap 1 e The table should have the facility for easily detachable kidney bridge attachment and the price shall be quoted optionally e Available with mattress o High density foam ILD 48 58 lbs 5
37. s and paddles Should have the facility for automatic external defibrillation for both adults and pediatric patients Should have ECG waveform display on bright high resolution display Should be compact and portable with inbuilt rechargeable battery Should not be more than 7 kgs with battery and paddles Should have an inbuilt recorder printing ECG trace and stored information Should have a facility of external non invading pacing with 40ms pulse width Should have ability to use ETCO2 both intibated amp nonintibated patients with main stream technology Should have user selectable alarm settings Should work on mains as well as on rechargeable battery Should be supplied with Adult and inbuilt Pediatric external paddles Should have facility to increase decrease energy selection on paddles preferred Charging time should be less than 7 secs at maximum energy Should have an inbuilt upgradation facility for SpO2 Should be supplied with following accessories items S L A Battery 1 no s 3 Lead ECG Cable 1no s External Defibrillator paddles pediatric inbuilt and adult 1 no s Multi function defibrillator amp monitoring pads gel sheets 150 no s Machine should be covered under 5 year warranty List of consumables if any with price frozen for 3 years should be quoted separately European CE or USFDA certificate approval required Warranty 3 years Warranty and 3 years CMC 12 Tender No 29 MPPHSC
38. s including bought out items should be under WARRANTY for a period of 3 years after successful commissioning All essential spare parts should be made available with the local service centre during the WARRANTY period and all steps should be taken for immediate servicing to prevent down time Comprehensive maintenance contract rates for 3 YEARS after warranty must be quoted and these would be taken into consideration while comparing price bids 45 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 A copy of service manual should be available with the local service centre Should have safety certificate from a competent authority European CE or FDA US approved product Complies with Medical Device Directive 93 42 EEC class risk lla or equivalent Manufacturer s quality management system complies with ISO 13485 Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system is required Warranty 3 years Warranty and 3 years CMC 32 Oxygen Hood Neonatal or Infant Size Unbreakable Oxygen Hood Paediatric e Transparent Acrylic for easy visibility e Neck Port adjustment to minimize the wastage of oxygen e Two side port to access procedures easily e Oxygen inlet Port e 02 cell Port temperature port e Various size for Pediatric Infant Neonatal 46 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Transparent Polycarbonate unbreakable single molded e Sili
39. t method in IEC 60068 2 32 In devices with a removable needle container the container must NOT be detached Drop test needle container only The container when full of needles and with the closure device engaged should be dropped 100 times onto a smooth concrete surface from a height of 1000mm No needles must fall out of the container Not more than one needle must pierce any of the sides The container must not be seriously damaged by the test Tilt angle The device must not tip over whether empty or full when placed on a 15 degree non slip plane with its short axis parallel to the line of tilt in general accordance with the test method in AS 4031 1992 30 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Leak proof The device must not leak any liquid contents when placed in the upright position at any angle between 0 and 15 degrees Needle escapes prevention The cutting assembly must be designed to prevent the migration of cut needles from the needle container into the needle aperture Cutting device closure mechanism If the device is intended to be carried with the needle container attached the needle aperture must have a closure mechanism to prevent needles from falling out of the attached needle container in any orientation of the assembly Needle container closure mechanism If the needle container is intended to be detachable it must have a secure closure mechanism that prevents spillage of sharps after detachment from the cut
40. taff of user department and support services till familiarity with the system is required e Rechargeable Battery having at least 5 6 hour backup for about 5ml hr flow rate with 50ml syringes Larger battery life and indication of residual life will be preferred Accessories spares and consumables e All standard accessories consumables and parts required to operate the equipment including all standard tools and cleaning and lubrication materials to be included in the offer Bidders must specify the quantity of every item included in their offer including items not specified above Operating Environment e The system offered shall be designed to be stored and to operate normally under the conditions of the purchaser s country The conditions include Power Supply Climate Temperature Humidity etc e Power supply 220 240 VAC 50Hz fitted with appropriate INDIAN 3 PIN plug The power cable must be at least 3 meter in length 38 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Standards and Safety Requirements e Must submit 1S013485 2003 AC 2007 for Medical Devices e Should have safety certificate from a competent authority European CE or FDA US approved product e Complies with Medical Device Directive 93 42 EEC class risk Ila or equivalent Manufacturer s quality management system complies with ISO 13485 e Demonstration Comprehensive Training for All Staff of user department and support services till familiarity with the system
41. ting assembly whatever the orientation of the container Needle container puncture resistance The needle container must pass the penetration resistance test in BS7320 1990 Needle container capacity The needle container must hold at least 150 nbr 20mm needles and or needle remains without affecting operation of the device Tamper proofing The needle aperture must be designed to prevent any part of the hand from entering Needles should not protrude from the needle container when it is filled up the level of the fill line Weight If intended to be portable the empty device complete with empty needle container should weigh a maximum of 750 grams User position The device must be comfortable to operate by 5th to 95th percentile adults in standing and seated positions with the device resting on a firm surface Handedness The device must be equally useable by left and right handed health workers Activation force The maximum force required cutting a standard 21 g needle needle hub or syringe nozzle should not exceed 67 N Smoothness of operation Complete needle removal or destruction must be achieved with a single smooth hand movement Hand to needle distance The distance from the needle to the hand holding or operating the needle cutter must exceed 50 mm while operating the device Blade edge protection The device s cutting blades must not expose the user to cut hazards either with or without the needle container connected Clea
42. uartz non ceramic infrared heating element with parabolic stainless steel reflector for uniform radiation of heat waves to all corners of the basinet Heater should be protected by a metal grid to prevent shock hazards e The heater box head should be either of swivel type and it must rotate to 90 from its axis or fixed type head provided it allows X Ray exposure from top e It should have LED display at least 1 for showing skin temperature in manual mode and set and skin temperatures in servo mode e Temperature display should be bright numerical The unit may have a rechargeable battery backup for display of temperatures amp alarm during power failure Optional 6 It should have an adjustable light source halogen LED for observation of the baby e The basinet comprises of foldable transparent acrylic side panels of minimum 6 mm in thickness and can be swivelled easily for cleaning and procedures e Basinet should not be fixed with the warmer if it is fixed then it should be detachable easily for cleaning purposes Both should move on lockable wheels e t must have one fixed transparent acrylic sheet below the mattress for under surface phototherapy and an additional acrylic tray with basinet for positioning the X ray cassette e The unit should have facility for inclination in both directions trendelenburg and reverse trendelenburg minimum up to 12 e Stitch less mattress should be supplied with a foam density of 21 25 kg m3 wit
43. ugs Trolley Medicine crash cart Utility hooks _ Cardiac board _Monitor Defibrillator Side shelf Drawers Seal for protection 4 e 12 5cm swivel media castors two are breaking e Corner buffers e Oxygen Cylinder holder provision e I V Rod provision e Cardiac massage board amp 3 laminated shelves 19 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 e Overall approx size 940mmL x 490mmW x 1535mmH e Six removable bins e Two Polystyrene storage unit with three drawers each Warranty 3 years Warranty Fire Extinguisher quote for 5 kg size Type of Cylinder Class ABC Type ABC Powder Base Fire Extinguisher Sub Type Constant Pressure Average Discharge Time s 8 Grade IS 15683 Test Pressure Kgf Cm 35 Operating temperature 0 C to 55 C External Testing Certification ISI European CE and ISO 9001 Extinguisher Type Constant Pressure Service Pressure 15 Kgf cm2 Material Type Mild Steel Min Effective Discharge 85 Use in Solid Combustible Fires Flammable Liquid Flammable Gas Electrically Started Fires Fire extinguisher e Must be BIS approved with ISI mark Capacity in Kg 500 gms 1 2 IS Specification 13849 13849 13849 Jet Range In Mtrs 1 5 2 4 2 4 Discharge Time In 6 8 8 10 8 10 Sec Min Discharge 85 85 85 Quantity 20 13849 4 5 15 20 85 10 13849 lt 6 23 30 85 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Seal of Appro
44. val ISI ISI ISI ISI Hydraulic Test 30 30 30 30 Pressure of Cylinder Kg Cm2 Discharge Outlet Direct Nozzle Direct Nozzle Direct Direct Nozzle Nozzle E Examination Table SS with mattress Examination Table SS with mattress at pre amp post Labour Area Size in mm 1830 L x 550 W x 800 H mm Three section top with Adjustable head section seat section and leg section Complete with SS bowl 32 cm diameter Standard padded Leg holder Top upholstered with waterproof synthetic material and finishing done using epoxy powder Made of MS tubular steel the beds should b sturdy wear amp tear resistant and long lasting Available with mattress e High density foam ILD 48 58 Ibs 50sq e Thickness 3 inch e Cover with venlylized nylon cover with Zipper ISI 30 Direct Nozzle e Cover is antibacterial anti static acid resistant waterproof and meets fire regulation cades 16CFR1633 amp 16CFR 1632 16 Foetal Doppler 21 Tender No 29 MPPHSCL 15 16 MCH Equip RC LIST1 Foetal heart Doppler 2 G9 ae So e Foetal Doppler European CE approved with blue blacklight for dark sight OPW e Easy operation for everyone over 10 years quality satisfaction e Tm 100B Foetal Doppler European CE Approved e Ultrasound frequency 2 5 0 25Mhz e Ultrasound output power 10mW cmDC e Power supply 9 6V rechargeable battery e Working environment temperature 10 40 e Features e Safe Ultrasound dosage is under 50

Download Pdf Manuals

image

Related Search

Related Contents

INSTALLATION MANUAL OF TML BTM BOLT STRAIN GAUGES  Seagate Constellation 1TB SAS 30 Pack  Philips In-Ear Headset SHE3575OP  Design and Implementation of Online Patient Monitoring System  モデル M130G, I/C, Intek Pro シリーズ(横軸) 取扱説明書  Philips Humidification filter HU4102  Translation of the Original Operating Instructions perma PRO / PRO  Samsung NP700Z3CH User Manual (Windows 8)  ISSUES/QUESTIONS?/ ¿PREGUNTAS?  User guide S40 D  