0130 Calibration Notes
Contents
1. provided with the column or if trimming has reduced the length of the column Additional information regarding each individual inlet detector make up gas or Aux Pressure Flow Calibration Ranges can be obtained by scrolling to the task and pressing the Info key Typically a calibrated flow of greater than 50 of the EPC module s flow range is required to calibrate A pressure greater than 70 of an EPC pressure range is required to calibrate it Jun 2001 Before Servicing the Instrument 1 of 2 Agilent 6890 Gas Chromatograph Service Manual 130 Calibration Notes Calibrating the 6890 GC Factory calibrations Whenever a user calibrated value is used the time and date of calibration is listed rather than the factory calibration message To return to factory calibrations the user calibration can be either completely deleted using the Delete key or can simply be turned Off to retain it in memory Recovery of user calibrations can be obtained by pressing the On key 2 of 2 Before Servicing the Instrument Jun 2001 Agilent 6890 Gas Chromatograph Service Manual
2. 130 Calibration Notes Calibrating the 6890 GC Press the Options key on the GC keypad and select the Calibration option to access a list of the 6890 Series GC parameters that can be calibrated Calibration options The following GC parameters can be calibrated The GC oven temperature can be corrected to actual measured temperature We do not recommend field calibration of flows and pressures other than zeroing A full calibration requires establishing flows and pressures that are comparable in accuracy to the NIST traceable factory equipment Flow sensors can be zeroed The Auto flow zero function when turned on automatically zeroes flow after each run To use this feature select Calibration on the OPTIONS menu then choose either Front inlet or Back inlet and turn Auto flow zero on After the end of a run Auto flow zero shuts down the flow of gases to an inlet waits for the flow to drop to zero measures and stores the flow sensor output and turns the gas back on This takes about two seconds The zero offset is used to correct future flow measurements Pressure sensors can be zeroed by fully depressurizing the system inlets or detectors Open appropriate fittings to ensure that there is no residual or trapped pressure then select Pressure Zeroing and press the On key Capillary columns can be calibrated Length and internal diameter can be estimated using data from an isothermal run This is useful when such data were not
Download Pdf Manuals
Related Search
Related Contents
Animation Pastorale - Pastorale scolaire de Liège 60 Series Service Manual.rev.1.2012 - Kold Commercial Electric HQV8011A Instructions / Assembly System One Description, Installation, and APWIN Guide user`s manual - UniPower LLC User's Manual TCP300II - STAR Microsoft security essentials LAB 2 Design and Simulation of Sequential Logic Circuits Copyright © All rights reserved.
Failed to retrieve file