installation instructions commercial dryer

image

Contents

1. 6777771 non coin operated models 7 1 8 181 mm SIDE VIEW coin operated 35 models 7 7 8 200 mm 889 mm 40 1 4 RIGHT SIDE EXHAUST i Y A i 4 1 4 1 108 mm 25 mm BOTTOM EXHAUST AWARNING I Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock IMPORTANT The dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 120 volt 60 Hz AC only 15 or 20 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this dryer be provided Recommended Ground Method The dryer when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition GROUNDING INSTRUCTIONS W For a grounded cord conn
2. Now stand the dryer up 6 Remove the service door of the meter case by lifting it up at the back Install the money accepting device Refer to manufacturer s instructions for proper installation For dryers using coin slides use adapter kit supplied with dryer 7 Replace the meter case service door Put the coin vault with lock and key in the meter case opening 8 Remove cardboard or hardboard from under dryer 10 Remove red cap from gas pipe Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for gas connections If flexible metal tubing is used be certain there are no kinks Open the shutoff valve in the gas supply line Test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leaks found Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Make sure the vent is secured to exhaust hood with a 4 102 mm clamp Move dryer into final position Do not crush or kink vent Make sure dryer is level Check to be sure there are no kinks in the flexible gas line With dryer in final position place level on top of the dryer first side to side then front to back If the dryer is not level adjust the legs of the dryer up or down
3. e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions In the State of Massachusetts the following installation instructions apply m Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts m f using a ball valve it shall be a T handle type m A flexible gas connector when used must not exceed 3 feet INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed AW ARN NG here Tools needed 8 or 10 pipe wrench m 8 or 10 adjustable wrench m Flat blade screwdriver m Phillips screwdriver Explosion Hazard m Adjustable wrench that opens to 1 25 mm or hex head Keep flammable materials and vapors such as socket wrench gasoline away from dryer m Level Do not install a garage 6 socket wrench Failure to do so
4. A External ground conductor screw B Tab C Terminal block cover D Hold down screw A Strain relief clamp sections B Dryer cabinet C Strain relief screws 4 Complete installation following instructions for your type of electrical connection Four wire recommended method Three wire if four wire is not available Power Supply Cord Four wire electrical connection Remove the center terminal block screw A Remove the appliance neutral ground wire from the external ground conductor screw Fasten under center silver colored terminal block screw Connect the ground wire of the power supply cord to the external ground conductor screw Tighten screw Connect the neutral wire white or center of the power supply cord under the center screw of the terminal block Tighten Screw 9 Connect the other wires to outer terminal A Spade terminals with upturned ends block screws Tighten screws B Neutral 10 Tighten strain relief screws A External ground conductor screw C 3 4 UL listed strain relief 11 Insert tab of the terminal block cover into Appliance neutral ground wire D Neutral white slot of the dryer rear panel Secure cover C Center terminal block screw E Ring terminals with hold down screw D Outer terminal block screws E Ground wire E Strain relief screw G Ground prong F Neutral center wire G Ground wire Four wire power supply cord must have four No 10 copper wires and match
5. 10 30R ground wire and the neutral wire white or center of the power supply cord under the center silver colored terminal block screw Tighten screw Connect the other wires to outer terminal block screws Tighten screws Tighten strain relief screws Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw 10 After reattaching the terminal cover connect a separate copper ground wire A Separate copper ground wire from the external ground conductor screw B External ground conductor screw to an adequate ground C Appliance neutral ground wire D Center terminal block screw E Outer terminal block screws Strain relief screw G Neutral center wire If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate 13 5 1 Disconnect power Direct Wire Method A WARNING A External ground conductor screw Fire Hazard B Tab C Terminal block cover D Hold down screw Use 10 gauge copper wire Use a UL listed strain relief Disconnect power before making electrical connections 2 Remove hold down screw and the terminal block cover 3 Install 3 4 conduit connector into the hole below the terminal block opening Connect flexible metallic conduit and tighten connector screw Install direct wire cable through the flexible a 8 7 Ee A Conduit
6. ft 14 6 m 2 44 ft 13 4 m 38 ft 11 6 m 8 85 ft 10 7 m 29 ft 8 8 m 4 27 ft 8 2 m 21 ft 6 4 m For vent systems not covered by the vent specification chart see Whirlpool Service Manual Exhausting Whirlpool Dryers Part No LIT603197 available from your Whirlpool parts distributor If dryer is installed in a confined area such as a bedroom bathroom or closet provision must be made for enough air for combustion and ventilation Check governing codes and ordinances See Recessed Area and Closet Installation Instructions in the Location Requirements section A four inch outlet hood is preferred However a 21 2 640 mm outlet exhaust hood may be used A 21 2 640 mm outlet creates greater back pressure than other hood types For permanent installation a stationary vent system is required Multiple Dryer Venting A main vent can be used for venting a group of dryers Main vent should be sized to remove 200 CFM of air per dryer Large capacity lint screens of proper design may be used in the main vent if checked and cleaned frequently The room where the dryers are located should have make up air equal to or greater than the CFM of all the dryers in the room Back draft Damper Kits Part No 3391910 are available from your Whirlpool dealer and should be installed in each dryer s vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main vent Un
7. minute 3 pins drying times are included in the parts bag The coin slide mechanism control panel lock and key and coin box lock and key are not included and are available from usual industry sources AWARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury NOTE Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering 1 Using two or more people move dryer to desired installation location 2 Take tape off front corners of dryer Open dryer and remove the literature and parts packages Wipe the interior of the drum thoroughly with a damp cloth 3 Take two of the cardboard corners from the carton and place them on the floor in back of the dryer Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners 4 With one of the legs in hand check the ridges for a diamond marking That s how far the leg is supposed to go into the hole 5 Start to screw the leveling legs into the holes by hand Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs Use a 1 inch wrench or socket wrench to finish turning the legs until you reach the diamond mark Now stand the dryer up 6 Remove the service door of the meter case by lifting it up at the back Install the money accepting device Refer to manufacturer s instructions for proper inst
8. of LP gas must be used Flexible metal appliance connector itis recommended that a new flexible stainless steel gas line design certified by CSA International be used for connecting the dryer to the gas supply line The gas pipe which extends through the lower rear of the dryer is provided with 3 8 male pipe thread Do not kink or damage the flexible stainless steel gas line when moving the dryer Rigid pipe connection p The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the dryer W Must include a shutoff valve The supply line must be equipped with a manual shutoff valve installed within 6 ft 1 8 m of dryer in accordance with National Fuel Gas Code ANSI Z223 1 This valve should be located in the same room as the dryer It should be in a A Gas supply line B Shutoff valve open position C To dryer location that allows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or shutting off gas to the dryer W Installed in a confined area If the dryer is installed in a confined area such as a bathroom or closet provision must be made for enough air for combustion and ventilation Check governing codes and T TEFLON is a registered trademark of E I Du Pont De Nemours and Company ordinances or refer to the Recessed Area and Closet Installation Instructions in the Location Requireme
9. until the dryer is level AWARNING I Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock Plug into a grounded 3 prong outlet Check dryer operation some accumulated time may be on the timer due to factory testing Insert coins in slide and press slide in slowly Operating time will accumulate per number of coins and type of timing cam used Push START RESTART button Using a full heat cycle not the air cycle let the dryer run for at least five minutes Dryer will stop when time is used up NOTE Dryer door must be closed for dryer to operate When door is open dryer stops but timer continues to run To restart dryer close door and push START RESTART button 4 lf the burner does not ignite and you can feel no heat inside the dryer shut off dryer for five minutes Check that all supply valve controls are in ON position and that the electrical cord is plugged in Repeat five minute test 5 If drying time is too long make sure lint screen is clean INSTALLATION INSTRUCTIONS ELECTRIC DRYER The console houses the factory installed accumulator timer with actuating arm and button The timer installed is set to provide 45 minutes 4 pins of drying time when activated by the coin slide Timer cams for 30 minute 6 pins and 60
10. E Dryer door must be closed for dryer to operate When door is open dryer stops but timer continues to run To restart dryer close door and push START RESTART button If drying time is too long make sure lint screen is clean 1 With dryer in final position place level on top of the dryer first Now start the dryer and allow it to complete a full heat cycle not air cycle to make sure it is working properly 15 CHANGING TO A 30 OR 60 MINUTE TIMING CAM AWARNING I Electrical Shock Hazard Disconnect power before making cam changes Failure to follow these instructions can result in death or electrical shock You can install the 30 minute or 60 minute timing cam shipped with dryer as follows 1 Unplug dryer or disconnect power 2 Unlock meter case 3 Turn the timing cam by hand until the V shaped notch lines up below the ratchet tooth 4 Insert a narrow flat blade screwdriver under the timing cam near the clock shaft Gently lift cam straight up and off shaft making sure that the V shaped notch clears the ratchet tooth Maintenance instructions m Clean lint screen before each cycle m Removing accumulated lint m From inside the dryer cabinet Lint should be removed every 2 years or more often depending on dryer usage Cleaning should be done by a qualified person m From the exhaust vent Lint should be removed every 2 years or more often depending on dryer usage If dryer does not operate chec
11. INSTALLATION INSTRUCTIONS COMMERCIAL DRYER Gas 120 Volt 60 Hz or Electric 120 240 Volt 60 Hz Table Of Contents sd ae E eroe acce aree sod o gn wor edo 2 8563800B TABLE OF CONTENTS DRYER SAFETY eee 2 INSTALLATION INSTRUCTIONS GAS DRYER 10 INSTALLATION REQUIREMENTS eere 4 Connect Ven nn ESI E UE IPIS 10 TOONS ANd PANS siden theses Dine hc needed aie dee 4 Complete Installation cease 10 Location Requirements 5 INSTALLATION INSTRUCTIONS ELECTRIC DRYER 11 Electrical Requirements ssena serae 6 Install Coin Slide and Coin 11 Gas Supply Requirements 224 7 Make Electrical 11 Venting Requirerrents 5 iac 8 Connect Vent a aa 15 INSTALLATION INSTRUCTIONS GAS DRYER 10 Complete Installation rores 15 Install Coin Slide and Coin 10 CHANGING TO A 30 OR 60 MINUTE TIMING CAM 16 Make Gas GConnectiOli ocn e Ea 10 DRYER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol Thi
12. a four wire receptacle of NEMA Type 14 30R The fourth wire ground conductor must be identified by a green cover and the neutral conductor by a white cover 12 Power Supply Cord Use this method where local codes permit connecting Three wire electrical connection neutral ground wire to ne E wire 5 Loosen or remove the center terminal block screw 6 Connect the neutral wire white or center of the power supply cord to the center silver colored terminal screw of the terminal block Tighten screw A Connect the other wires to outer terminal block screws Tighten screws Tighten strain relief screws Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw This blade connected to A External ground conductor screw this conductor B Center terminal block screw C Outer terminal block screws D Strain relief screw E Neutral center wire Appliance neutral ground wire A Spade terminals with upturned ends B Ring terminals Use this method where local codes do not permit C Neutral white or center connecting neutral ground wire to neutral wire D 3 4 UL listed strain relief E Neutral 5 Remove the center terminal block screw Three wire power supply cord must 6 Remove the appliance neutral ground wire have three No 10 copper wires and from the external ground conductor match a three wire receptacle of NEMA screw Connect the appliance neutral Type
13. a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug on the power supply cord if it will not fit the outlet have a proper outlet installed by a qualified electrician SAVE THESE INSTRUCTIONS AWARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 13 330 mm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire IMPORTANT Observe all governing codes and ordinances This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 NFPA 54 A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 The design of this dryer has been certified by CSA International for use at altitudes up to 10 000 feet 3048 m above sea level at the B T U rating indicated on the model serial plate Burner input adjustments are not required when the dryer is operated up to this elevat
14. allation For dryers using coin slides use adapter kit supplied with dryer 7 Replace the meter case service door Put the coin vault with lock and key in the meter case opening 8 Remove cardboard or hardboard from under dryer Power Supply Cord Method This dryer is manufactured with the neutral ground wire connected to the neutral center of the wiring harness at the terminal block If local codes do not permit this type of connection use Four wire connection instructions Use a new UL listed power supply cord rated 240 volt min 30 amp and marked for use with a clothes dryer 1 AWARNING Fire Hazard Use a new UL listed 30 amp power supply cord Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Earth wire green or bare wire must be connected to green earth connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock Disconnect power 11 2 Remove hold down screw and the terminal block cover 3 Assemble 3 4 UL listed strain relief UL marking on strain relief into the hole below the terminal block opening Tighten strain relief screws just enough to hold the two clamp sections together Install power supply cord cable through the strain relief
15. areas free from the accumulation of lint dust remove the door to the drying compartment and dirt Do not reach into the dryer if the drum is moving The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel Do not dry articles that have been previously cleaned in washed in soaked in or spotted with gasoline dry Do not install or store the dryer where it will be exposed to the weather See installation instructions for grounding requirements Do not tamper with controls SAVE THESE INSTRUCTIONS IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Canadian Natural Gas and Propane Installation Code CSA B149 1 The dryer must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Clear the room building or area of all occupants
16. can result in death explosion or fire m Utility knife m Vent clamps m Pipe joint compound resistant to LP gas If installing a gas dryer m Caulk gun and caulk for installing new exhaust vent IMPORTANT Observe all governing codes and ordinances Pis Check code requirements Some codes limit or do not permit installation of clothes dryers in garages closets or sleeping m Putty knife quarters Contact your local building inspector Parts supplied B Make sure that lower edges of the cabinet plus the back and bottom sides of the dryer are free of obstructions to permit Remove parts bag from dryer drum Check that all parts were adequate clearance of air openings for combustion air See included Recessed Area and Closet Installation Instructions below for Wedge cone minimum spacing requirements Dryer foot 4 NOTE The dryer must not be installed in an area where it will be 556 18 x 21 2 bolt exposed to water and or weather 3 pin timing cam 6 pin timing cam Recessed Area and Closet Installation Instructions This dryer may be installed in a recessed area or closet For recessed area and closet installations minimum clearances can be found on the serial tag on the dryer The installation spacing is in inches and is the minimum allowable Additional spacing should be considered for ease of installation servicing and compliance with local codes and ordinances If closet door is installed the minimu
17. connector B Dryer cabinet C Connector screw Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining A 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock Direct wire cable must match power supply 4 wire or 3 wire and be Flexible armored cable or nonmetallic sheathed copper cable with ground wire protected with flexible metallic conduit All current carrying wires must be insulated 10 gauge solid copper wire do not use aluminum At least 5 ft 1 52 m long metallic conduit gt Complete installation following instructions for your type of electrical connection Four wire recommended method Three wire if four wire is not available Direct Wire Four wire electrical connection Remove the center terminal block screw Remove the appliance neutral ground wire from the external ground conductor screw Fasten under center silver of wires colored terminal block screw to stripped of disconnect insulation Connect the ground wire green or bare of the direct wire cable to the external ground conductor screw Tighten screw Place the hooked end of the neutral wire white or center of the direct wire cable under the center screw of the terminal block hook fac
18. ected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician SAVE THESE INSTRUCTIONS IMPORTANT The dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition The National Electrical Code requires a 4 wire supply connection for homes built after 1996 dryer circuits involved in remodeling after 1996 and all mobile home installations If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Prot
19. ection Association One Batterymarch Park Quincy MA 02269 A four wire or three wire single phase 120 240 volt 60 Hz AC only electrical supply or four wire or three wire 120 208 volt if specified on the model serial rating plate is required on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Recommended Ground Method It is your responsibility to contact a qualified electrical installer to ensure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances GROUNDING INSTRUCTIONS W For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances W For a permanently connected dryer This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer WARNING Improper connection of the equipment grounding conductor can result in
20. ing right Squeeze hook end together Tighten screw I 31 2 89 mm A 1 25 mm 5 127 mm Strip 5 127 mm of outer covering from end of cable Leave green or bare Shape ends ground wire at 5 127 mm Cut 11 2 of wires into 38 mm from 3 remaining wires Strip a hook insulation back 1 25 mm A 3 4 conduit connector B Neutral white or center C Ground wire green or bare D 10 gauge 3 wire with ground wire in flexible metallic conduit 14 Place the hooked ends of the other direct wire cable wires under the outer terminal block screws hook facing right Squeeze hooked ends together Tighten Screws Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw A External ground conductor screw B Appliance neutral ground wire C Center terminal block screw D Outer terminal block screws E Neutral center wire Green or bare ground wire Direct Wire Three wire electrical connection Three wire with ground wire green or bare wire cut short Wire is not used Dryer is grounded through neutral conductor A 1 25 mm of wires Use this method where local codes permit connecting neutral ground wire to neutral wire 5 Loosen or remove the center terminal block screw 6 Place the hooked end of the neutral wire white or center of the direct wire cable under the center screw of
21. ion When installed above 10 000 feet 3048 m a four percent 4 reduction of the burner B T U rating shown on the model serial plate is required for each 1 000 foot 305 m increase in elevation For assistance when converting to other gas types and or installing above 10 000 feet 3048 m elevation contact your local service company Type of Gas This dryer is equipped for use with natural gas It is design certified by CSA International for L P propane and butane gases with appropriate conversion No attempt shall be made to convert the dryer from the gas specified on the serial rating plate for use with a different gas without consulting the serving gas supplier Conversion must be done by a qualified service technician Gas conversion kit part numbers are listed on the gas valve burner base Gas Supply Line Recommended method Provide a gas supply line of 1 2 rigid IPS pipe to the dryer location Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape With LP gas piping or tubing size can be 1 2 minimum Usually LP gas suppliers determine the size and materials used in the system Alternate method The gas supply may also be connected using 3 8 approved copper or aluminum tubing If the total length of the supply line is more than 20 feet 6 1 m larger tubing will be required If using natural gas do not use copper tubing Pipe joint compounds that resist the action
22. k the following m Electric supply is connected m Circuit breakers are not tripped or fuses are not blown m Door is closed m Controls are set in a running or ON position m START button has been pushed firmly m For gas dryers check that gas supply shutoff valves are set in open position 8563800B 2008 All rights reserved 5 Place new cam hub side down over clock shaft Line up flat side of shaft with flat side of cam hole Check that drive lug is in place A Ratchet tooth B Timing cam C Drive lug Turn cam until V shaped notch lines up with ratchet tooth 7 Press cam down in place on clock shaft Make sure that V shaped notch clears the ratchet tooth Close and lock the meter case Plug dryer or reconnect power If you need assistance The Commercial Laundry Support Center will answer any questions about operating or maintaining your dryer not covered in the Installation Instructions The Commercial Laundry Support Center is open 24 hours a day 7 days a week Just dial 1 800 NO BELTS 1 800 662 3587 the call is toll free When you call you will need the dryer model number and serial number Both numbers can be found on the serial rating plate located in the dryer door well 11 2008 Printed in U S A
23. l position Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance The total length of flexible metal duct shall not exceed 73 4 ft 2 4 m An exhaust hood should cap the vent to prevent rodents and insects from entering the home or business Exhaust hood must be at least 12 305 mm from the ground or any object that may be in the path of the exhaust such as flowers rocks or bushes If using an existing vent system clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint Replace any plastic or metal foil vent with rigid metal or flexible metal vent Plan installation to use the fewest number of elbows and turns Exhaust Air Flow A Better B Good Allow as much room as possible when using elbows or making turns Bend vent gradually to avoid kinking Vent outlet is located at the center of the bottom dryer back The vent can be routed up down left right behind the dryer or straight out the back of the dryer Vent System Length Maximum length of vent system depends upon the type of vent used number of elbows and type of exhaust hood The maximum length for rigid metal venting is shown in the chart Maximum Vent Length 4 102 mm Diameter Exhaust Hoods Box Hood and Louvered Style Rigid Metal Vent No of 90 turns Angled Hood Style 0 64 ft 19 5 m 58 ft 17 7 m 1 54 ft 16 5 m 48
24. m unobstructed air opening in the top and bottom is required Louvered doors with equivalent air openings are acceptable The dryer must be exhausted outdoors No other fuel burning appliance may be installed in the same closet as the dryer Minimum Installation Clearances 14 356 mm max 15 381 corel 0 0 0 0 E Recessed front view Closet side view Additional clearances for wall door and floor moldings may be required or if external exhaust elbow is used 3 76 mm 4 555555555554 310 sq Front View Closet door 24 sq in pne 155 sq ome 3 76 mm Opening is the minimum for a closet door A Louvered doors with equivalent air openings are acceptable Product Dimensions 29 737 mm dryer 737 mm 774 __ 1 BACK VIEW ELECTRIC c 406 27 1 4 13 4 102 mm mm 1 1 4 32 lt lt 18 3 8 467 g 25 1 2 648 mm gt 477771 f I non coin operated models 35 7 1 8 181 mm 889 mm SIDE VIEW coln opetaied models 7 7 8 200 mm 1 Y 25 mm UA Product Dimensions 27 686 mm dryer 686 n F ELECTRIC 55 gt 14 356 mm BACK VIEW 6 3 4 152 mm 1 1 4 gt 32 mm 29 1 4 743 mm 26 1 2 673 mm gt
25. nts section Gas Supply Pressure Testing A 1 8 NPT minimum plugged tapping accessible for gauge testing must be installed immediately upstream of the gas supply connection to the dryer The dryer must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1 2 psig AWARNING Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS IMPORTANT Observe all governing codes and ordinances Only rigid or flexible metal duct shall be used for exhausting The dryer vent must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building Do not use an exhaust hood with a magnetic latch Do not install flexible metal vent in enclosed walls ceilings or floors 4 102 mm heavy metal vent and clamps must be used Use clamps to seal all joints Vent must not be connected or secured with screws or other fastening devices which extend into the interior of the vent and catch lint Do not use duct tape Use a heavy metal vent Do not use plastic or metal foil vent Rigid metal vent is recommended to prevent crushing and kinking Flexible metal vent must be fully extended and supported when the dryer is in its fina
26. obstructed air openings are required Each vent should enter the main vent at an angle pointing in the direction of the airflow Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents The maximum angle of each vent entering the main vent should be no more than 30 ZA air flow B 30 max A Individual dryer vent B Main vent Keep air openings free of dry cleaning fluid fumes Fumes create acids which when drawn through the dryer heating units can damage dryers and loads being dried A clean out cover should be located on the main vent for periodic cleaning of the vent system If an exhaust hood cannot be used The outside end of the main vent should have a sweep elbow directed downward If the main vent travels vertically through the roof rather than through the wall install a 180 sweep elbow on the end of the vent at least 2 feet 610 mm above the highest part of the building The opening wall or roof shall have a diameter 1 2 13 mm larger than the vent diameter The vent should be centered in the opening A Exhaust hood or elbow B Wall C Main collector vent D Horizontal vent E 180 sweep elbow Vertical vent Do not install screening or cap over the end of the vent G Roof 2 ft 610 mm min above highest point of building INSTALLATION INSTRUCTIONS GAS DRYER The console houses the factory installed accum
27. s supplier m Post the following warning in a prominent location FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury to persons when using the dryer follow basic precautions including the following Read all instructions before using the dryer Do not repair or replace any part of the dryer or attempt Do not place items exposed to cooking oils in your dryer any servicing unless specifically recommended in this Items contaminated with cooking oils may contribute to Use and Care Guide or in published user repair a chemical reaction that could cause a load to catch fire instructions that you understand and have the skills to carry out Do not use fabric softeners or products to eliminate static cleaning solvents or other flammable or explosive unless recommended by the manufacturer of the fabric substances as they give off vapors that could ignite or softener or product explode Do not use heat to dry articles containing foam rubber or Do not allow children to play on or in the dryer Close similarly textured rubber like materials supervision of children is necessary when the dryer is Clean lint screen before or after each load used near children Keep area around the exhaust opening and adjacent Before the dryer is removed from service or discarded surrounding
28. s symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately A DANGER follow instructions You can be killed or seriously injured if you don t follow A WARN l N G instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING risk of Fire Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to the manufacturer s instructions and local codes Do not install a clothes dryer with flexible plastic venting materials If flexible metal foil type duct is installed it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire To reduce the risk of severe injury or death follow all installation instructions Save these instructions It is recommended that the owner post a prominent location instructions for the customer s use in the event the customer smells gas This information should be obtained from your ga
29. the terminal block hook facing right Squeeze hooked end together Tighten screw Place the hooked ends of the other direct wire cable wires under the outer terminal block screws hook facing right Squeeze hooked ends together Tighten screws Insert tab of the terminal block cover into A External ground conductor screw B Center terminal block screw C Outer terminal block screws to stripped of insulation D Neutral center wire slot of the dryer rear panel Secure cover E Appliance neutral ground wire with hold down screw Use this method where local codes do not permit connecting neutral ground wire to neutral wire 3 1 2 89 mm 5 Remove the center terminal block screw Remove the appliance neutral ground wire from the external ground conductor screw Connect the appliance neutral ground wire and the neutral wire white or center of the direct wire cable under the center silver colored terminal block screw Tighten Strip 3 1 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire cable with ground wire cut green or bare wire even with outer covering Shape ends of wires into a hook A 3 4 conduit connector B Neutral white or center C 10 gauge 3 wire with ground wire in flexible metallic conduit Screw Connect the other wires to outer terminal block screws Tighten screws Insert tab of the terminal block cover into slot of the dr
30. ulator timer with actuating arm and button The timer installed is set to provide 45 minutes 4 pins of drying time when activated by the coin slide Timer cams for 30 minute 6 pins and 60 minute 3 pins drying times are included in the parts bag The coin slide mechanism control panel lock and key and coin box lock and key are not included and are available from usual industry sources AWARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury NOTE Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering 1 Using two or more people move dryer to desired installation location 2 Take tape off front corners of dryer Open dryer and remove the literature and parts packages Wipe the interior of the drum thoroughly with a damp cloth 3 Take two of the cardboard corners from the carton and place them on the floor in back of the dryer Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners 4 With one of the legs in hand check the ridges for a diamond marking That s how far the leg is supposed to go into the hole 5 Start to screw the leveling legs into the holes by hand Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs Use a 1 inch wrench or socket wrench to finish turning the legs until you reach the diamond mark
31. yer rear panel Secure cover with hold down screw After reattaching the terminal cover connect a separate copper ground wire from the external ground connector screw to an adequate ground If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A Separate copper ground wire B External ground conductor screw C Appliance neutral ground wire D Center terminal block screw E Outer terminal block screws Neutral center wire 2 Plug in dryer or reconnect power Check dryer operation Some accumulated time may be on 1 Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Make sure the vent is secured to exhaust hood with a 4 102 mm clamp side to side then front to back If the dryer is not level adjust the legs of the dryer up or down until the dryer is level the timer due to factory testing Insert coins in slide and press slide in slowly Operating time will accumulate per number of coins and type of timing cam used Push START RESTART button Using a full heat cycle not the air cycle let the dryer run for at least five minutes 2 Move dryer into final position Do not crush or kink vent Make Dryer will stop when time is used up sure dryer IS even NOT