User manual Affinity® III - Frank`s Hospital Workshop

image

Contents

1. Foot Section Not Locked Into Position OneStep Foot Supports To return to the storage position squeeze the release latch again and return the supports to the desired position The maximum safe working load is 150 Ib 68 kg 12 Affinity I Rev 000 Hill Rom 4 10 Headboard The headboard includes built in handles which aid in steering control and increase mobility The headboard assembly is removable To Remove Grasp the hand holds firmly and lift up To Install Align the headboard sockets with the posts on the bed frame and lower the headboard until it rest on the bed frame 4 11 IV Pole USER MANUAL The Affinity Three Birthing Bed comes equipped with one IV pole stored at the head end of the bed on the headboard The IV pole sockets are located at each corner of the bed at the head end Deploy Remove the IV pole from the holders Insert the pole into the desired socket and turn clockwise until it drops fully into the socket and locks into place The maximum safe working load is 25 Ib 11 kg 4 12 Labor Grips Ergonomically correct labor grips comfortably accommodate patients of all sizes The handles are covered with a non porous fluid resistant foam that is comfortable for mothers to squeeze To Activate To raise the labor grip grasp the grip and rotate it from under the bed until it clicks in place To lower pull t
2. Pendant Control Affinity III 22 Rev 000 Hill Rom USER MANUAL 6 14 Permanent IV Pole The Permanent IV Pole mounted on the head section frame enables additional IV bags and pumps to be mounted on either side of the bed The maximum safe working load is 25 Ib 11 kg To Deploy e Lift the IV pole from its stored position behind the headboard and position it straight up Permanent IV Pole Make sure that the pole drops and locks into position e Raise the upper section of the pole to the desired height The IV pole is ready for use To Store e Grasp and hold the upper section of the IV pole Push the upper collar down and lower the upper pole section into the lower pole section Lift the lower section of the IV pole up and lower the pole down to the stored position behind the headboard The poles should rest in the storage slots provided on the bed frame A CAUTION Do not mount infusion pumps on the lower section of an IV pole Interference with head section articulation could result 6 15 Phone and Phone Adaptor The patient phone attaches to either siderail by using the adaptor 6 16 Sheets e A sheet set includes pillow case top and custom fitted bottom sheets Aqdditionally the two piece bottom set is available separately Before the Affinity Bed is used by a patient sheets must be placed over the mattress Affinity II Rev 000 23 USER MANUAL Hill Rom
3. 6 17 Siderail Pads The siderail pads are simply placed over the siderail for protection against patient injury Siderail Pads 6 18 Slipcovers Head and Foot Head The head section slipcover is simply placed over the head section mattress for protection from normal wear and tear and from fluids Foot Section Slipcover The foot section slipcover is simply placed h over the foot section mattress for protection i from normal wear and tear and from fluids oo Head Section Slip Cover 6 19 Wedge Assembly To quickly convert the V Cut Seat Section to a straight edge slide the wedge assembly into the V Cut seat section Wedge Assembly Affinity III 24 Rev 000 Hill Rom USER MANUAL 7 Patient Positioning Labor and Birth NOTE The Labor and Delivery Drape should be placed over the bottom sheet before the patient gets into the bed To allow the patient to participate show her how to operate the controls 7 1 Upright Position Voiding Position e Raise the head of the bed to a comfortable position by pressing the Head Up control e Lower the foot section by pressing the Foot Down control e Place the patient in an upright position e Place the bed pan backward into the V Cut on the foot section Aspeciman container may also be used Slide it between the mattress and bed frame e Position the patient out and over the V Cut having her hold the labor grips for support
4. Ifthe patient s legs are unstable position her feet with the soles together to prevent sliding Affinity III Rev 000 25 USER MANUAL 7 2 7 3 7 4 Lateral Position Sims With the bed in the lowest position and the head of the bed adjusted for the patient s comfort position the attached calf support with the foot end pointed toward the head of the bed With the patient lying on her left side place her right leg in the support and lower the foot section for comfort Adjust the support and tighten the joint Kneeling Position Raise the head section of the bed to the full upright position Have the patient kneel on the seat section and use the head section of the bed for support Legs Elevated With Foot Mattress This position is useful for various clinical reasons during antepartum care postpartum care and anesthesia administration when a patient s legs require elevation It may also be used for patient comfort To Adjust 26 Raise the foot section to its highest position Fold in the hinged part of the foot section mattress Hill Rom Place the patient s legs on the elevated mattress section Affinity III Rev 000 7 5 Squatting With The Labor Bar 7 6 7 7 With the bed in the lowest position raise the head by pressing the Head Up control and lower the foot section by pressing the Foot Down control Insert the labor bar into the leg s
5. ss ass ma aaklala m aala alaya aa ala anal aa a a a E 10 4 5 Central Brake and Steer 0000 cece RR KK KS 10 4 6 CPR Rele ase sg a a aka kla EELER a ay rer EEE EEE ERNES 11 4 7 Fluid Basin sas ka x aa l an kak al ak a ala usa a a a al al a 11 4 8 Foot Section Lift Off or Slide Om 12 4 9 OneStep Foot Supports Jk kk kk kk kk kk kk kk kk kk kk 14 4 10 Headboard osc 5 a 4 5 5i a 2dl k aa cae BTS EE awa wes aya aaay ana 15 4 11 1V Pole i kun mana MEN aa a SEENEN NIE Ne a a aa 15 4 12 Labor Gps 5s ss x EENS ed aera al kaai a aaa A E 15 4 13 Lockout Controls e KK K kK kk kk kk 16 4 14 Night Light ees s EUREN ELSEN ELE EELER wea NS es 16 4 15 SiderailS x kx a al k aa ve k ama x n ak alan kk ka ak a a 16 4 16 Trend Like Function 000 KK KK RR KK RR KK KK KK kk 17 5 Optional Features 17 5 1 Air Support System 0 0 kk kk kak kk kak kk kk kk kk kk kak 17 5 2 Siderail Controls RONN ks kk kk a kall k teat a a waned a ee as 18 5 2 1 Built In SideCom Communication System Controls Optional ss tasie ec ee weed eae ee hee k a ws ee os 18 6 Acessories 5 2 EN dl Wad bab eee Ce eek ee 19 6 1 Anesthesia Screen e eis cei ee eee dia Ne ne 20 6 2 Arm Board 5 22666 kak sla eee eng die epee see ee ee NES ee 20 6 3 EasyGlide Calf Supports kk kk kk kk kk eee eee 21 6 4 Comfort Pad es oie eis kk kk k kk kk k kk kk kk
6. Do not expose the unit to excessive moisture Personal injury or equipment damage could occur A CAUTION Do not use harsh cleaners solvents or detergents Equipment damage could occur General Cleaning Clean the unit with a lightly dampened cloth and ordinary disinfectants Do not use excessive liquid Steam Cleaning Do not use any steam cleaning device on the Affinity Three Birthing Bed Excessive moisture can damage mechanisms in this unit Cleaning Hard to Clean Spots To remove difficult spots or stains use standard household cleaners and a soft bristle brush To loosen heavy dried on soil or excreta you may first need to saturate the spot Disinfecting Dilute disinfectants and germicides as specified on the manufacturer s label Affinity III Rev 000 37 USER MANUAL Hill Rom Care of Wood Components Wood is selected for use on beds because of its beauty and warmth All Hill Rom wood products are treated with a resin based sealer and finish that provide resistance to abrasion staining fluids and fire Many disinfectant cleansers have a softening effect on any painted or finished surface if used in high concentrations Diluted ammonia mild detergents and diluted bleach solutions may be used Clean by wiping a soft dampened cloth over the surface followed by wiping with a dry cloth At no time should a wet cloth be allowed to lay on the surface Any liquid spilled on the surface should be wiped
7. Air system fuse air system optional 2 A 250 V 5 x 20 mm UL 198G Fast Acting Battery fuse 10 A 32 V ATO Mains fuse 120 V bed model 4 A 250 V 5 x 20 mm UL 198G Slo Blo or equivalent Mains fuse 230 V bed model 2 A 250 V 5 x 20 mm IEC127 Sheet III Time Delay a Slo Blo is a registered trademark of Littelfuse Inc Table 9 Auxiliary Outlet Power Specifications Condition Auxiliary outlets Range 12V AC 20 W per outlet elec trically isolated from earth ground Affinity III Rev 000 45 USER MANUAL Hill Rom Table 10 Classification and Standards The Affinity Three Birthing Bed is designed and manufactured according to equipment classifications and the following standards Technical and Quality Assurance Stan dards EN 60601 1 and amendments UL 2601 1 CSA C22 2 No 601 1 IEC 60601 2 38 IEC 60601 1 2 EN ISO 9001 and EN 46001 Equipment Classifications per EN 60601 1 Class I equipment internally powered equipment Water Degree of Protection Against Electric Type B Shock of the Applied Part Classification according to Directive Class I 93 42 EEC Degree of Protection Against Ingress of IPX2 Degree of Protection Against the Pres ence of Flammable Anaesthetic Mixtures Ordinary equipment not for use in a flammable atmosphere Mode of Operation Continuous operation with intermitt
8. The information contained in this manual is subject to change without notice Hill Rom makes no commitment to update or keep current the information contained in this manual The only product warranty intended by Hill Rom is the express written warranty accompanying the bill of sale to the original purchaser Hill Rom makes no other warranty express or implied and in particular makes no warranty of merchantability or fitness for a particular purpose To order additional copies of this manual call 800 445 3720 and place a parts order for part number usr025 Revision Letter Pages Affected Date Original Issue October 2000 Hill Rom USER MANUAL TABLE OF CONTENTS 1 Typographical Conventions 2 Intended Use gg kk kk kk kk kk kk kk kk kk kk lk kk 9 Jotrogducton ve la a ee ce ask k kk WE Aa deet 4 Features g c awk a a ak kad kl kak a ka g kal dk Waa aid k 4 1 Automatic Tilt 2 52028 s ka kalak ya kk ara a E Nee ak va zanlna ana 4 2 Battery Backup lk kk kk kk kk kk kk kk kk kk kk kk ak kk kk kk kk 4 3 Bed Controls ue gut ma NEEN dwar ede aa RER aes 4 3 1 Back Section Lumbar Mattress Control Optional 4 3 2 Foot Section 0 0 eee eee 4 3 3 Head Section igus n eke ea eo ed Wa ka dk eh eed 4 3 4 Nurse Call Optional 2 0 0 0 00 KK KK KK RR KK KK 4 3 5 Seat Section Mattress Control Optional 4 3 6 TV On Off Optional 10 4 4 Bed Models
9. amp Sons Inc 1 Dartex is a registered trademark of Courtaulds Textiles Holdings Limited Affinity III Rev 000 39 USER MANUAL Hill Rom 10 Product Symbol Definition The following symbols are used on the Affinity Three Birthing Bed Symbol Description A Type B applied part according to EN 60601 1 IPX2 According to IEC 529 A CAUTION Consult accompanying documents CE Conforms to the European Medical Device Directive 93 42 EEC U US 3R17 Certified by Underwriters Laboratory in accor dance with UL2601 1 CAN CSA C22 2 NO 601 1 EN 60601 1 IEC 601 2 38 and IEC 601 1 2 CPR function ldentifies the release lever that can be used to manually drop the inclined head section in order that cardiopulmonary resuscitation can be performed without delay m gt e lt Lockout control label The switch in the up position indicates the lockout control is on The switch in the down position indicates the lockout control is off refer to the section titled Lockout Controls on page 16 for lockout sta tus information 40 Affinity III Rev 000 Hill Rom USER MANUAL Symbol Description Battery charge status refer to the section titled Battery Backup on page 5 for battery status information Nurse call refer to the section titled Nurse Call Optional on page 9 for nurse call switch information Lockout co
10. immediately remove the bed from service and contact the appropriate maintenance personnel Failure to do so could result in personal injury or equipment damage Use only Hill Rom power cords as a replacement Other power cords have not been investigated for compliance with electrical safety standards for this product A WARNING If the integrity of the external protective earth conductor is in doubt operate the bed from its internal electrical power source Failure to do so could result in personal injury Affinity III Rev 000 33 USER MANUAL Hill Rom A CAUTION This device meets all requirements for electromagnetic compatibility per IEC 601 1 2 and the Medical Device Directive and has been fully tested to such requirements It is unlikely that the user will encounter problems with this device because of inadequate electromagnetic immunity However electromagnetic immunity is always relative and standards are based on anticipated environments of usage If the user notes unusual device behavior particularly if such behavior is intermittent and associated with nearby usage of radio or TV transmitters cell phones or electrosurgical equipment this could be an indication of electromagnetic interference If such behavior occurs the user should try moving the interfering equipment further from this device Policies and procedures must be established to train and educate your staff on the risks associated with electric equipme
11. Unplug the bed from its power source e Remove the patient from the bed Clean the fluid spill from the bed system Have maintenance inspect the system completely Do not put the bed back into service until it is completely dry tested and determined to be safe to operate Affinity III Rev 000 31 USER MANUAL Hill Rom Siderails Restraints Patient Monitoring The siderails should always be in a full upright position and latched when a patient is unattended When raising the siderails an audible click indicates that the siderails are completely raised and locked in place Siderails are intended to be a reminder not a patient restraining device Hill Rom recommends the appropriate medical personnel determine the level of restraint necessary to ensure a patient will remain safely in bed Consult the restraint manufacturer s instructions for use to verify the correct application of each restraining device WA wanna Siderails are not intended to be used as restraint devices Medical personnel should determine the appropriate use of siderails and ensure patient safety Failure to do so could result in patient injury 1 Develop guidelines for all patients that indicate e Which patients may need to be restrained and the appropriate restraint to utilize The proper method to monitor a patient whether restrained or not including time interval visual check of restraint etc 2 Develop training programs for all caregiv
12. allow the bed to move to the full Trend Like position Affinity Ill Rev 000 5 USER MANUAL 4 3 2 Foot Section The Foot Up Foot Down controls located on both siderails enable you to raise or lower the foot section of the bed 9 23 cm of travel from its lowest position Location Caregiver and patient siderails right hand and left hand The Foot Up Down buttons are the arrows located on the right side of the label To Activate Press and hold the Foot Up button to raise the foot section of the bed Hill Rom 4 A Sm Vv y Foot Section Controls Press and hold the Foot Down button to lower the foot section of the bed NOTE If the foot section is at its lowest position when the bed is lowered the bed will stop at a higher position to ensure that the foot section does not interfere with the base 4 3 3 Head Section The Head Up Head Down controls located on both siderails enable you to raise or lower the head section of the bed The head section can be raised to any angle of inclination up to 63 Location Caregiver and patient siderails right hand and left hand The Head Up Down buttons are the arrows located on the left side of the label To Activate Press and hold the Head Up button to raise the head section of the bed 4 A v y Head Section Controls Press and hold the Head Down button to lower the head section of the bed Affinity III
13. support devices Location Two locations on both sides of the head section The maximum safe working load is 40 Ib 18 kg ISS System Affinity III Rev 000 21 USER MANUAL 6 11 Labor Bar For extra support the labor bar fits into the leg support sockets between the seat and foot cushions To Adjust To raise or lower the bar use the Foot controls The bar can be used in either direction for different positions and purposes The maximum safe working load is 100 Ib 45 kg Labor Bar 6 12 Oxygen Tank Holder The oxygen tank holder attaches to the head end of the frame in a vertical position The oxygen tank holder accommodates one E size oxygen tank with a regulator The mounting points are located to enable the oxygen tank holder to pivot Installation e Install the mounting bar vertically into a mounting socket at the head end of the 4 bed frame e Place the tank in the holder and tighten Oxygen Tank Holder the holder thumbscrew The thumbscrew keeps the oxygen tank from rotating in the holder Removal e Loosen the thumbscrew that secures the tank in the holder and lift the tank out of the holder e Lift up on the oxygen tank holder and remove it from the mounting sockets The maximum safe working load is 30 Ib 14 kg 6 13 Pendant Control The pendant controls Bed Up Down Head Up Down Foot Up Down To Activate Push the appropriate buttons
14. up immediately Any liquid allowed to lay on the surface unattended may damage the finish For protection of the finish we recommend using a liquid type furniture polish Polish about once a month and wipe off any excess with a soft dry cloth Have any nicks or scrapes repaired to prevent water damage Mattress Care and Draping Correct draping technique is essential in preserving the life of the mattress Drapes must be fluid repellent The Hill Rom labor and delivery drape effectively covers the lower three quarters of the bedding throughout labor Additional pads or towels placed under the patient will help prevent fluid from reaching the edges of the drape This safeguard keeps the sheets clean and dry while preventing fluid exposure to the mattress NOTE Standard OB packs and paper drapes will not keep the sheets dry Repeated soaking of mattress materials will accelerate wear and eventually destroy mattress seals causing fluids to leak into the cushions Hill Rom slipcovers are recommended to help extend the life of the mattress NOTE Mattress damage caused by improper draping and cleaning procedures is not covered by warranty NOTE Sheets must always be placed over the mattress before the bed is used by a patient Affinity III 38 Rev 000 Hill Rom USER MANUAL The following products have been tested by the Herculite Laboratory and have been found not to have a harmful effect on Dartex fabrics when used in acc
15. 480 Ib 218kg maximum Affinity III Rev 000 43 USER MANUAL Hill Rom Table 3 Specifications for Product P3700 Feature Dimension Head Section Inclination maximum 63 Seat Section Inclination maximum 15 Bed Height Range 18 46 cm to 34 86 cm Bed Height Range with mattress 22 56 cm to 38 97 cm Trend Like position maximum 89 Bed Lift capacity maximum safe working load 500 Ib 227 kg Foot Section Lift capacity maximum 400 Ib 181 kg Head Section Lift capacity maximum 200 Ib 91 kg Maximum Height of Seat Section in Trend Like position 40 102 cm Table 4 Product Identification Product Number P3700 Description Affinity Three Birthing Bed Table 5 Environmental Conditions for Transport and Storage Condition Temperature Range 40 F 40 C to 158 F 70 C Relative humidity 95 non condensing Pressure 500 hPa to 1060 hPa Table 6 Environmental Conditions for Use Condition Range Temperature 59 F 15 C to 104 F 40 C ambient temperature Relative humidity range 10 to 85 non condensing 44 Affinity III Rev 000 Hill Rom USER MANUAL Table 7 Mains Power Requirements Condition Range Rated voltage 120V AC 230V AC Power input 4 A 2 A Frequency 50 60 Hz Table 8 Fuse Specifications Condition Range
16. Ill Rev 000 1 USER MANUAL Hill Rom 2 Intended Use The Affinity Three Birthing Bed is intended to be used as a birthing bed for women of child bearing age within the acute care Labor and Delivery market It is not intended for use as a general hospital bed 3 Introduction This manual provides the information required for normal operation of the Affinity Three Birthing Bed from Hill Rom Before operating the Affinity Three Birthing Bed be sure that you have read and understood in detail the contents of this manual It is important that you read and strictly adhere to the aspects of safety contained in this manual Any reference to a side of the bed is from the patients view lying in the bed on their back 4 Features Affinity III Rev 000 Hill Rom USER MANUAL 4 1 Automatic Tilt e As the head section is raised the seat section gradually tilts up from 0 to k A 15 ma W e As the head section _ is lowered the seat section gradually Se 7 returns to a flat position 4 2 Battery Backup The Affinity Three Birthing Bed is designed with battery backup as a standard feature The battery allows the KO hilow foot and head motors to be activated from the siderail controls without power being supplied to the bed In addition the battery backup powers the nurse call function but it does not power any other bed functions such as the optional air support system Battery Backup Indica
17. Rev 000 Hill Rom USER MANUAL 4 3 4 Nurse Call Optional On Affinity Three Birthing Beds equipped with the optional nurse call feature use the Nurse Call button to place a call to the nurse call system Above the Nurse Call button the Call indicator light illuminates on the patient s siderail controls indicating a call has been made E Location Caregiver and patient siderails right hand Nurse Call and left hand Button To Activate e Press and release the Nurse Call button e Speak into the speaker microphone located on the patient s side of the head end siderails A CAUTION If power to the bed is lost the nurse call function can still operate up to 4 hours depending on the charge of the battery Before becoming completely non functional the system will place a non cancellable nurse call NOTE The Nurse Call controls cannot be locked out 4 3 5 Seat Section Mattress Control Optional The Seat Section Mattress Control enables you to inflate or deflate the seat section mattress in order to attain a degree of firmness or softness Location Caregiver and patient siderails right hand and left hand To Activate To auto inflate the seat section press the Caregiver Seat Inflate Button plus sign To cancel the auto inflate function press the Caregiver Seat Inflate Button plus sign again To auto deflate the seat section press the Caregiver Seat Deflate Button minus si
18. User manual Affinity lll 2000 by Hill Rom Services Inc ALL RIGHTS RESERVED No part of this text shall be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or by any information or retrieval system without written permission from Hill Rom Services Inc Hill Rom First Edition First Printing 2000 Printed in the USA Affinity is a registered trademark of Hill Rom Inc Beaucoup is a registered trademark of Huntington Laboratories Inc CSA is a registered trademark of Canadian Standards Association Inc Dartex is a registered trademark of Courtaulds Textiles Holdings Limited EasyGlide is a trademark of Hill Rom Inc Galahad is a registered trademark of Puritan Chemical Company Hi Tor is a registered trademark of Huntington Laboratories Inc Hill Rom is a registered trademark of Hill Rom Inc Matar is a registered trademark of Huntington Laboratories Inc OneStep is a trademark of Hill Rom Inc Quanto is a registered trademark of Huntington Laboratories Inc SideCom is a registered trademark of Hill Rom Inc Slo Blo is a registered trademark of Littelfuse Inc Staph Chek is a registered trademark of Herculite Products Inc Surfacide is a registered trademark of Walton March Inc Vesphene II is a registered trademark of E R Squibb amp Sons Inc Virex is a registered trademark of S C Johnson amp Son Inc
19. ase latch and rotate the calf support to the upright position The calf supports lock when in the upright position e Adjust the calf support using the release handle NOTE Check for pressure points and make appropriate adjustments For TALL PATIENTS angle the support downward For SHORT PATIENTS angle the support upward The maximum safe working load is 60 Ib 27 kg 6 4 Comfort Pad The comfort pad is simply placed on top of the mattress and fitted securely around the mattress corners It rolls up into a compact bundle for storage 6 5 Disposable Drape The full size absorbent disposable labor and delivery drape covers the entire seat foot and lower backrest and tucks into the fluid basin when the end of the bed is removed The drape should be placed over the bottom sheet before the patient gets into bed with the soft absorbent surface next to the patient waterproof side down Affinity III Rev 000 USER MANUAL Hill Rom 6 6 Foley Hook Kit The maximum safe working load is 20 Ib 9 kg 6 7 Foot Rest Bar The maximum safe working load is 150 Ib 68 kg Foley Hook Kit Foot Rest Bar 6 8 Full Leg Supports To Adjust for Use 20 Electrically lower the foot section to the lowest position with the patient s legs on the foot section before placing her legs into the supports Both full leg supports are interchangeable right and left For leg support installation place the r
20. d transport handles to move the bed during transport Do not transport patients while the bed is in the chair position Failure to do so could result in personal injury or equipment damage WARNING Make sure that the patient equipment and all lines including power cords are securely placed within the perimeter of the bed for intra hospital transport Failure to do so could result in personal injury or equipment damage WARNING Fully extended IV poles could impact doorways or ceiling fixtures Lower the poles prior to patient transport Failure to do so could result in personal injury or equipment damage WARNING Be sure to connect the nurse call SideCom Communication System cables after transport is complete Failure to do so could result in personal injury WARNING Do not leave the bed exposed to extreme environmental conditions for extended periods of time Possible equipment damage could occur WARNING Transport the bed in a low position and ensure that the bed is not transported over a side inclination of more than 5 Failure to do so could result in personal injury or equipment damage Affinity III Rev 000 Hill Rom USER MANUAL 9 Cleaning EY SEET Follow the product manufacturer s instructions Failure to do so could result in personal injury or equipment damage A WARNING Unplug the unit from its power source Failure to do so could result in personal injury or equipment damage A wne
21. e desired position by using the Head Up control Position the patient s legs in calf supports Push down on the Trend Like handle to place the patient in modified Trend Like position and to raise the perineum Affinity III Rev 000 Hill Rom USER MANUAL 8 Safety Tips For over 70 years Hill Rom has set the standard for quality in patient beds During this time with input from many of our customers we have acquired these useful tips Bed Positions AX aiie Make sure the bed is in the low position when the patient is unattended This can reduce the possibility of patient falls and the severity of any resultant injuries Brakes By wasite Always set the brakes when the bed is occupied except during patient transport To help ensure the bed will not move push and pull on the bed to check it after the brakes are engaged Brakes should always be set when the bed is occupied and especially when moving a patient from one surface to another Patients often use the bed for support when getting out of bed and could be injured if the bed unexpectedly moves After setting the brakes push and pull the bed to insure stability Fluids De caine Significant fluid spills onto the bed electronics can result in a hazard If such a spill occurs unplug the bed and remove it from service Failure to do so could result in personal injury or equipment damage When massive fluid spills occur on the bed immediately e
22. ection Mattress Lumbar control enables you to inflate or deflate the back section lumbar mattress in order to attain a degree of firmness or softness Location Caregiver and patient siderails right hand and left hand To Activate To inflate the back section press and hold the Back Firm button plus sign until the Back Section desired firmness is attained Mattress Controls To deflate the back section press and hold the Back Deflate button minus sign until the desired softness is attained 4 3 1 1 Bed Up Bed Down Hilow The Bed Up Bed Down controls located on both siderails allow you to raise or lower the bed 16 41 cm The low position is for general use and to assist with patient egress while the high position is used for patient procedures Location Caregiver siderail right hand and left hand To Activate Press and hold the Bed Up button to raise the bed Press and hold the Bed Down button to lower the be A WARNING Leave the bed in the low position when the patient is unattended This can reduce the possibility of patient falls and the severity of any resultant injuries NOTE If the foot section is at its lowest position when the bed is lowered the bed will stop at a higher position to ensure that the foot section does not interfere with the base NOTE If the bed is in the low position and the Trend Like function is activated the bed will rise to the appropriate height to
23. end Like Positioning j 31 7 12 Throne Position Chair 31 7 13 Birthing Bed Mode 31 7 14 Delivery Table Mode 32 7 15 High Modified Trend Like Position Birth And Repair 32 8 Safety Tips siza cence nodded eee deme dete SE ees 33 9 CIGANING ENEE E STEEN ENEE NENNEN 39 10 Product Symbol Definition 42 11 Technical Specifications 00 e eee eee 45 Affinity III Rev 000 Hill Rom USER MANUAL 1 Typographical Conventions This manual contains different typefaces and icons designed to improve readability and increase understanding of its content Note the following examples e D D Standard text used for regular information Boldface text emphasizes a word or phrase NOTE sets apart special information or important instruction clarification The symbol below highlights a WARNING or CAUTION Warning and Caution A AWARNING identifies situations or actions that may affect patient or user safety Disregarding a warning could result in patient or user injury A CAUTION points out special procedures or precautions that personnel must follow to avoid equipment damage The symbol below highlights a CAUGHT HAZARD WARNING Caught Hazard Warning E3 The symbol below highlights a CHEMICAL HAZARD WARNING Chemical Hazard Warning tE The symbol below highlights an ELECTRICAL SHOCK HAZARD WARNING Electrical Shock Hazard Warning Affinity
24. ent loading 3 minutes ON 30 minutes OFF a CSA is a registered trademark of Canadian Standards Association Inc 46 Affinity III Rev 000 France Hill Rom BP 14 Z I du Talhou t 56330 Pluvigner Tel 33 0 2 97 50 92 12 Service Clients 33 0 802 01 23 45 Fax 33 0 2 97 50 92 00 GB United Kingdom Hill Rom Clinitron House Ashby Park Ashby de la Zouch Leicestershire LE65 1JG Tel 44 0 1530 411333 Fax 44 0 1530 411555 NL Nederlands Hill Rom BV Hagenweg 1c Postbus 173 4130 ED Vianen Tel 31 yee 32 35 32 Fax 31 0 347 32 35 00 CP Portugal Iberdata Equipamentos S A Rua Dr Ricardo Jorge 4 Venda Nova 2700 301 Amadora Tel 351 21 476 8170 Fax 351 21 476 8179 e mail iberdata lisboa mail telepac pt Cs Sverige Medibed AB PO BOX 3035 Djursholmsvagen 29 18303 Taby Tel 46 875 67 110 Fax 46 873 26 938 e mail maggani limedic se QD5133 Belgique Belgi Distribal Admiral De Boisot Straat 19 21 2000 Antwerpen Tel 32 32 38 43 15 Fax 32 32 16 06 86 Cp Deutschland Hill Rom Kurhessenstrasse 11 64546 M rfelden Tel 49 0 6105 9320 Fax 49 0 6105 932 182 CE Espana Hijo de Jose Mani S A C Roca Humbert n 37 08907 l Hospitalet de Llobregat Tel 34 93 338 71 11 Fax 34 93 261 06 17 Ellas Patient Care Solutions Chaiziioannidis Nikolaos G lordanidi 2 Str 54635 Thessaloniki Te
25. ers concerning the proper use and application of restraints 3 Maintain the bed at its lowest position whenever a caregiver is not in the room 4 Clarify the need for restraint devices to families or guardians Electricity dl wasn Unplug the bed from its power source and activate the lockout switches before cleaning or service Failure to do so could result in personal injury or equipment damage Affinity III 32 Rev 000 Hill Rom USER MANUAL Verify that the lockout switch is activated before cleaning or servicing the bed The battery backup provides power to the bed functions even when the bed is unplugged from its power source A A A WARNING Establish policies and procedures to train and educate your staff on the risks associated with electrical equipment Failure to do so could result in personal injury or equipment damage WARNING Significant fluid spills onto the bed electronics can result in a hazard If such a spill occurs unplug the bed and remove it from service Thoroughly clean the bed and allow it to dry then have the bed checked by service personnel CAUTION Before transporting the bed ensure that the power cord is stored on the power cord wrap holder provided on the headboard Failure to do so could result in equipment damage WARNING Improper use or handling of the power cord may result in damage to the power cord If damage has occurred to the power cord or any of its components
26. facility authorized personnel should perform preventive maintenance on the Affinity Three Birthing Bed Preventive maintenance performed by unauthorized personnel could result in personal injury or equipment damage The Affinity Three Birthing Bed requires an effective maintenance program We recommend that you perform annual preventive maintenance PM and testing for Joint Commission on Accreditation of Healthcare Organizations JCAHO PM and testing not only meet JCAHO requirements but will help ensure a long operative life for the Affinity Three Birthing Bed PM will minimize downtime due to excessive wear For the preventive maintenance schedule refer to the Affinity Three Birthing Bed Service Manual man272 Troubleshooting A WARNING Only facility authorized personnel should troubleshoot the Affinity Three Birthing Bed Troubleshooting by unauthorized personnel could result in personal injury or equipment damage Always check the battery charge status on the siderail The bed may not be functioning due to the battery being drained and the bed needing to be plugged into its appropriate power source Affinity III Rev 000 35 USER MANUAL Hill Rom Transport A A gt FF gt gt 36 WARNING The Affinity Three Birthing Bed is intended to be used to transport patients with the foot end of the bed forward Prior to transport properly store the power cord to help prevent tripping Use only the headboar
27. g the following methods If the foot section height can be adjusted e Adjust the foot section so that the top of the mattress is about waist high e Pivot the foot supports laterally e Grasp and hold the foot section between the snaps as close to the body as possible e Lift Off Foot Section Lift and slide the foot section toward you bending your knees while taking a step backward e Slide Off Foot Section Squeeze the release levers to disengage the foot section and slide the section toward you bending your knees while taking a step backward e Turn the top of the foot section up and with the knees bent place it on the floor with the stand down to hold it upright If the foot section is well below the waist and cannot be adjusted Affinity III 10 Rev 000 Hill Rom USER MANUAL Pivot the foot supports laterally Approach the foot section from an angle side or front Place one leg forward and one leg back bending the knees slightly Grasp and hold the foot section between the snaps as close to the body as possible Lift Off Foot Section Lift and slide the foot section toward you while taking a step backward Slide Off Foot Section Squeeze the release levers to disengage it and slide the foot section toward you while taking a step backward Turn the foot section so the stand is down and with the knees bent place it on the floor To Install Grasp the foot section w
28. gn To Seat Section cancel the auto deflate function press the Mattress Caregiver Seat Deflate Button minus sign Controls again To inflate or deflate the seat section from the patient controls press and hold the Patient Seat Inflate Button plus sign or the Patient Seat Deflate Button minus sign NOTE The auto inflate function runs for 20 to 25 seconds before shutting off Affinity Ill Rev 000 7 USER MANUAL 4 3 6 TV On Off Optional The TV on off button turns on and off the audio for the television and radio Location Patient siderail control panel right hand and To Activate Press and release the TV button The green left hand indicator light illuminates and the television and radio audio come on The television and radio volume controls on the patient siderail On Off control panels are now operational Buttons Mise hors tension Press and release the TV button The green indicator light goes off and the television and radio audio are muted 4 4 Bed Models The Affinity Three Birthing Bed is available in two options the V Cut or the Straight Edge 4 5 Central Brake and Steer The Affinity Three Birthing Bed is equipped with 2 wheel braking and 1 wheel steering To Activate V Cut Straight Cut To brake press down firmly on the Brake Pedal designated by an orange dot Two casters will immediately lock into place Push and pull on the bed to en
29. he release latch and lower the grip under the bed Affinity III Rev 000 Built In Labor Grips 13 USER MANUAL Hill Rom 4 13 Lockout Controls The Lockout controls deactivate the hilow head and foot functions on the bed When a lockout is activated both the patient and caregiver controls for motor gl functions are locked out Location The Lockout control is located on the frame at the head end of the bed The Lockout control LED indicator is located on the caregivers side of both siderails LED Indicator To Activate Press the Lockout control switch to deactivate the motors The lockout LED indicator on the siderail will light Activating the lockout function does not affect the operation of the emergency CPR Release 4 14 Night Light A photo cell control automatically turns the light on when the room darkens and turns it off when the room gets brighter The night light does not function when the bed is powered by the battery Location The night light is located on the bottom center of the bed frame 4 15 Siderails The Affinity Three Birthing Bed has two siderails one located on each side of the bed The head end siderails contain caregiver and patient siderail controls and can be adjusted between the upright and lowered positions To Adjust To raise or lower the siderails pull the Siderail Release Latch on the siderail and swing the siderail into the de
30. in the siderails on both sides of the bed The patient controls are always in full view of the patient and the international graphic symbols provide easy orientation Patient head and foot section controls are embedded in the inside panel of the siderails on both sides of the bed for the patient s convenience Powered operation allows the patient to respond to her body signals and reduces her dependence on staff assistance for positioning support and comfort These controls include Head Up Head Down and Foot Up Foot Down Staff controls are embedded in the outside panel of both siderails In addition to head and foot section controls the outside panel contains controls for the hilow operation Wood Headboards ae The wood headboards includes built in handles which aid in steering control and increase mobility The headboard assembly is removable To Remove Grasp the hand holds firmly and lift up To Install Align the headboard sockets with the posts on the bed frame and lower the headboard until it rest on the bed frame Affinity III 16 Rev 000 Hill Rom 6 Accessories USER MANUAL Table 1 Accessories List Product Number Description P9625 Anesthesia screen P9620 Arm board P3704 Calf supports EasyGlide P35745A Calf supports telescoping P3612 Comfort pad B7831 Disposable drape P3623 Foley hook kit P451 Foot res
31. ith both hands Position the foot section onto the mounting brackets located on the bed frame Lift Off Foot Section While holding the foot section level lift and slide it until the latches securely engage and a level surface is achieved Slide Off Foot Section While holding the foot section level push it until the latches securely engage and a level surface is achieved Pull on the foot section to ensure that it is locked into position Affinity III Rev 000 11 USER MANUAL NOTE If the foot section is not level this is an indication that it is not locked into position Lift the foot section to the level position and push until the latches securely engage A vne The foot section must be fully secured under the mattress to provide safe support Possible personal injury or equipment damage could occur The foot section must be locked into place Pull to ensure that the latch is engaged 4 9 OneStep Foot Supports The OneStep Foot Supports can be simultaneously positioned up or down through use of the motor powered foot section yoke This foot section yoke controls the overall height up and down Each support can be independently positioned by using the mechanical release latches at the end of the foot supports To Adjust the Foot Supports To position the patient s legs squeeze the release lever and rotate the foot support The foot support rotates upward and outward from 0 to 85
32. kk lk kk kak kk kak 21 6 5 Disposable Drape J kk kk kk kk kk kk kk kk kk kk kk kk kk kk 21 6 6 Foley Hook Kit 00 kk kk kk kk kk kk kk kk kk kk kk kk kk kak 22 Affinity III Rev 000 USER MANUAL Hill Rom 6 7 Foot Rest Bar 22 6 8 Full Leg Supports 2s sees sew kk EST kk kk kk kk kk sees 22 6 9 Instrument Tray 23 6 10 Infusion Support System SS 23 6 11 Labor Bar 1 cece a kla dala eee 24 6 12 Oxygen Tank Holder 24 6 13 Pendant Control 24 6 14 Permanent IV Pole 25 6 15 Phone and Phone Adaptor kak kk kk kk kk kk kk kk 25 Ehe sc ka D sin le e ale ara e O teas lees di 25 6 17 Siderail Pads i i eee kk kk kk kak kk kak EEN ia 26 6 18 Slipcovers Head and Foot 26 6 19 Wedge Assembly 0 00 cece eee kk kk kk kk kk kk kk 26 7 Patient Positioning Labor and Birth 27 7 1 Upright Position Voiding Position 0 eee eee 27 7 2 Lateral Position Sims 0 kk eee eee eee 28 7 3 Kneeling Position 28 7 4 Legs Elevated With Foot Mattress 0 0 e ee eens 28 7 5 Squatting With The Labor Bar 20020eeeee 29 7 6 Pushing With The Labor Bar kak eee eee eee 29 7 7 Pushing With The Labor Bar With Foot Supports 29 7 8 Pushing with Calf Supports 0 0c cece eee eee 30 7 9 Epidural Spinal Lateral Approach 30 7 10 Epidural Sitting Approach 30 7 11 Straight Line Tr
33. l 30 31 960 303 Fax 30 31 960 087 Danmark Gondorf Medical Holevey 30 2970 Horsholm Tel 45 455 70 881 Fax 45 455 70 650 e mail Info gm medical dk CH Suisse Schweiz Hill Rom SA Chemin du Vallon 26 1030 Bussigny Tel 41 0 21 706 21 30 Fax 41 0 21 706 21 33 e mail hrch info hill rom CA Osterreich Hill Rom Joh Bukowansky GmbH Buropark Donau Haus 8 nkustrasse 1 7 3400 Klosterneuburg Tel 43 0 2243 28550 Fax 43 0 2243 28550 19 e mail austria hill rom com C1 Italia Hill Rom S p A Via Ambrosoli 6 20090 Rodano Tel 39 02 950541 Fax 39 02 95328578 CN Norge Avalon Medical Biscop Gens Nilssongate 5 0659 Oslo Tel 47 23 03 63 70 Fax 47 23 03 63 71 International HILL ROM CO INC INTERNATIONAL DEPARTMENT 1069 STATE ROUTE 46 EAST J55 BATESVILLE INDIANA 47006 USA Tel 1 812 934 8173 Fax 1 812 934 7191 WEBSITE www hill rom com e mail international hill rom com
34. nt It is never prudent or necessary for personnel to place any part of their body under or between moving parts of the bed Whenever a bed is being cleaned or serviced it should be unplugged from its power source and the lockout switch should be activated to keep the bed from accidentally operating due to the battery backup If service personnel need to get under the bed the hilow portion must be blocked up as an added precaution Refer to the Affinity Three Birthing Bed Service Manual man272 Parts and Accessories Use only Hill Rom parts and accessories Do not modify the bed system without authorization from Hill Rom Operating Precautions A A 34 WARNING Do not operate the bed in the presence of flammable gas or vapors Failure to do so could result in personal injury or equipment damage WARNING Use oxygen administering equipment of the nasal mask or ventilator type only Do not use the bed with oxygen tents Failure to do so could result in personal injury or equipment damage Affinity III Rev 000 Hill Rom USER MANUAL A wamne Deactivate the bed functions using the lockout control Movement of a patient or inadvertent activation of the bed functions by anyone else could result in personal injury Lockout Controls Activate the lockout control at the head end of the bed to keep a patient or visitor from operating the motor function on the siderail controls Maintenance A WARNING Only
35. ntrol status when the lockout control status light is on the lockout function is activated gt EI Ei lt gt e O Identifying mains fuse Alternating current Equipotentiality gt lt n Safe working load Affinity III Rev 000 41 USER MANUAL Hill Rom Symbol A Description Electric shock hazard Keep feet clear of this area Potential for injury Trend Like function 42 Affinity III Rev 000 Hill Rom 11 Technical Specifications USER MANUAL Table 2 Dimensions for Product P3700 Feature Total Length Dimension 90 229 cm Length from roller bumpers to break in seat section 61 7 8 157 cm Length from break in the seat section to end of bed 28 1 8 71 cm Maximum Width siderails stored 36 91 cm Maximum Width siderails up 39 99 cm Maximum Headboard Height 52 132 cm Maximum Siderail Height without mat tress 1434 37 47 cm Minimum Under Bed Clearance 5 13 cm Wheel Base 50 127 cm x 29 74 cm Mattress Width 35 89 cm Mattress Length 78 198 cm Mattress Thickness head seat 4 10 cm Mattress Thickness foot 3 8 cm Detachable Power Cord IEC 320 inter face US 84 213 cm international 98 248 9 cm Caster Size 6 15 cm or 8 20 cm Total Weight
36. od into the steel sockets located at the point where the foot L section attaches to the yoke 5 Drop them into the sockets and tn rotate until you hear the support lock Full Leg Supports Rotate the supports so that the black knob faces inboard toward the patient and leave the knob loose For large patients rotate the black knob outboard away from the patient Place the patient s legs into the supports Adjust the position by rotating her knees out Tighten the black knob gt Affinity III Rev 000 Hill Rom USER MANUAL Raise the foot section electrically to fill in the popliteal space by pushing the Foot Up control The patient s legs should be completely supported e Remove the foot section e Rotate the foot supports up and away from the center of the bed NOTE Check for pressure points and make appropriate adjustments For TALL PATIENTS angle the support downward For SHORT PATIENTS angle the support upward The maximum safe working load is 60 Ib 27 kg 6 9 Instrument Tray The instrument tray is available in both a lift off and slide off version Location The instrument tray is located at the foot section of the bed in the foot section yoke The maximum safe working load is 25 Ib 11 kg 6 10 Infusion Support System ISS The ISS System accommodates integration of the Hill Rom s Infusion Support System for placement of infusion
37. ordance with manufacturer s recommended dilution Trade Name Type Manufacturer A33 uartenary Airwick Absolute Quartenary Walton March Beaucoup Phenolic Huntington Blue Chip Quartenary S C Johnson Coverage 256 Quartenary Vestal El Dorado Plus Quartenary Puritan Churchill Elimstaph Quartenary Walter G Legge Forward DC Quartenary S C Johnson Frenklin Sentine Quartenary Purex Galahad Phenolic Puritan Churchill Hi Tor Quartenary Huntington Insurance Quartenary Vestal LPH Phenolic Vestal Matar Phenolic Huntington Omega Quartenary Airwick Quanto Quartenary Huntington Sanikleen Quartenary West Chemical Sanmaster III Quartenary Service Master Surfacide Quartenary Walton March Tri Quat Quartenary Vestal Vesphene II Phenolic Vestal Virex Quartenary S C Johnson Deep Purple N A N A Betagone N A N A a Galahad is a registered trademark of Puritan Chemical Company b Surfacide is a registered trademark of Walton March Inc c Virex is a registered trademark of S C Johnson amp Son Inc d Beaucoup is a registered trademark of Huntington Laboratories Inc e Hi Tor is a registered trademark of Huntington Laboratories Inc f Matar is a registered trademark of Huntington Laboratories Inc g Quanto is a registered trademark of Huntington Laboratories Inc h Vesphene II is a registered trademark of E R Squibb
38. osition Pull up the labor grips Remove the foot section and tuck the drape into the drainage pan Tilt up the foot support Raise the bed to a comfortable height by pressing the Bed Up control and position the patient s perineum out and over the edge of the seat section Affinity I Rev 000 29 USER MANUAL Hill Rom 7 14 Delivery Table Mode With Calf Supports With Full Leg Supports NOTE Check pressure points 7 15 High Modified Trend Like 30 Slide the patient down so that her buttocks are at the division in the mattress Lower the foot section to its lowest position Position the attached calf supports and place the patient s legs in the supports Adjust the angle of the supports and tighten the ball joints Adjust the angle of the leg supports and tighten the black winged knob Push the Foot Up control to raise the leg supports so that they securely support the patient s perineum over the cut out space Remove the foot section and raise the bed to a comfortable working height Press the Foot Up control to raise the supports so that they securely support the patient s perineum over the edge of the seat section Remove the foot section and raise the bed to a comfortable working height The drainage pan can also be removed for extra exposure Position Birth And Repair Raise the bed to the desired height using the Hilow control Raise the head section to th
39. sired position When raising e the siderails you will hear a click when the siderail is securely in Head End Siderail place To store a siderail lower it completely and push it in under the bed surface A ne After changing the position of the siderails tug on them slightly to ensure that they are securely locked in place Failure to do so could result in patient injury Affinity III 14 Rev 000 Hill Rom USER MANUAL 4 16 Trend Like Function e The Affinity Three Birthing Bed can achieve up to 8 of Trend Like positioning You can P activate the Trend Like controls at any bed J height When the bed is in its lowest position e TEN and the Trend Like function is activated the bed will rise to the appropriate height in order to go into the full Trend Like 8 position To Activate To position the sleep surface in a Trend Like position push down on the handle and guide the bed to the desired degree up to 8 To level the sleep surface pull up on the handle and guide the bed to a level position Trend Like Function 5 Optional Features 5 1 Air Support System The Affinity Three Birthing Bed features air surface controls located on both the outside and inside of the siderail for both seat and lumbar support These controls provide improved patient comfort during labor recovery and postpartum while minimizing the cost maintenance and labor concerns associated with the
40. sure the Central Brake brakes are set and Steer To release press firmly on the Steer Pedal until both pedals are level neutral position SE press down firmly on the Steer Pedal designated by a green ot To release press firmly on the Brake Pedal until both pedals are level neutral position A WARNING Ensure the brakes are set when transferring a patient to or from the Affinity Three Birthing Bed Failure to do so could result in the bed moving during the transport which could result in personal injury Affinity III Rev 000 Hill Rom USER MANUAL 4 6 CPR Release The CPR Release enables the caregiver to save valuable time in an emergency When activated the CPR Release automatically lowers the head and seat section to the flat position which creates a firm surface to support a CPR board To Activate Pull the emergency CPR Release handle on either side of the bed Release your hand when the head section is down to the lowest position Emergency CPR Release Handle 4 7 Fluid Basin The fluid basin is reversible and easily removed for cleaning To Remove Replace e Pull the fluid basin straight out Slide the basin straight into the holding devices Shake the basin gently to ensure it is securely seated bell Fluid Basin Affinity III Rev 000 9 USER MANUAL Hill Rom 4 8 Foot Section Lift Off or Slide Off To Remove The foot section can be removed by usin
41. t bar P7625C Full leg supports attached P7634C Full leg supports telescoping P278 P27802 Instrument tray lift slide P156 ISS mobile stand kit P159 ISS offset bar P158 ISS transfer pole P3613 Labor bar P276 O2 Tank holder P5362 Pendant control P497 Pendant holder P222101 Permanent IV Pole P495 Phone P496 Phone adaptor SA1528 Sheets V cut compete SA1529 Sheets straight compete SA4885 Sheets V cut two piece SA4586 Sheets straight two piece P3705 Siderail pads P3628B Slipcover cut head section air P3630EA Slipcover foot section Affinity III Rev 000 USER MANUAL Hill Rom Product Number Description P3626B Slipcover straight edge head section without air P3627B Slipcover straight edge head section air P3625B Slipcover V cut head section without air P3619 Wedge Assembly 6 1 Anesthesia Screen The base of the frame slides between the mattress and the frame The screen can be positioned on either side of the bed The maximum safe working load is 5 Ib 2 3 kg 6 2 Arm Board The arm board is held in place between the frame and mattress The padding is removable for cleaning The maximum safe working load is 30 Ib 14 kg Arm Board Affinity III 18 Rev 000 Hill Rom USER MANUAL 6 3 EasyGlide Calf Supports To Adjust for Use e Fold in the hinged mattress e Rotate the foot supports all the way upward and outward e Pull the rele
42. tors Location The battery backup indicator is located on the siderail to indicate the battery condition Battery Backup LED Indicators e ON Battery status is operational e FLASHING Battery needs charging e OFF Battery is discharged below the level required to run the motors NOTE If the battery has been completely discharged it may take up to 36 hours to recharge to operational status A CAUTION Remove the battery if the bed will not be in service for extended periods of time Failure to do so could result in damage to the life of the battery or damage to the bed Contact the appropriate maintenance personnel and refer to the Affinity Three Birthing Bed Service Manual man272 Affinity Ill Rev 000 3 USER MANUAL Hill Rom To ensure the battery is always charged plug the bed into the appropriate power source whenever possible Disposal Power comes from a lead acid battery which needs to be disposed of properly according to your local regulations For assistance in disposing of the battery contact your maintenance technician Pb 4 3 Bed Controls The Affinity Three Birthing Bed is electrically operated using siderail or pendant controls The hilow head and foot functions can be operated by battery backup if necessary Patient Control Panel Affinity III 4 Rev 000 Hill Rom USER MANUAL 4 3 1 Back Section Lumbar Mattress Control Optional E The Back S
43. uck away one siderail e Position the bed to a comfortable height and lower the head of the bed e Place the patient in a lateral recumbent position at the mattress edge 7 10 Epidural Sitting Approach e Raise or lower the bed to a comfortable height for the staff and flatten the bed Have the patient dangle her legs over the opposite side of the bed 28 Hill Rom USER MANUAL 7 11 Straight Line Trend Like Positioning e Pull the CPR Release to lower the head of the bed to a full flat position e Push down on the Trend Like handles located on either side of the bed and guide the bed to the desired degree up to 8 To level the sleep surface pull up on the handle and guide the bed to a flat position General Anesthesia In an emergency position the bed to a comfortable height e Remove the headboard Position the patient for intubation 7 12 Throne Position Chair e Raise the head of the bed to place the patient in a sitting position e Pull up the labor grips e Position the patient s feet in the foot supports e Remove the foot section Use the Foot control to raise or lower the Foot Supports Tuck the end of the drape into the drainage pan and raise the bed to a comfortable height by pressing the Bed Up control 7 13 Birthing Bed Mode e Position the patient s feet in the foot supports Raise the supports to a comfortable p
44. upport sockets so it angles away from the head of the bed The patient may squat on the seat section holding the Labor Bar or sit with her feet on the foot section leaning forward onto the bar Pushing With The Labor Bar Raise the head of the bed to a comfortable position by pressing the Head Up control Insert the labor bar into the support sockets so it angles away from the head of the bed Lower the foot section if needed by pressing the Foot Down control Place the patient s feet on either side of the Labor Bar The patient may grip the labor grips or pull back on her knees Pushing With The Labor Bar With Foot Supports Raise the head of the bed toa comfortable position by pressing the Head Up control Remove the foot section Place the patient s feet on the foot supports and adjust for comfort Insert the labor bar into the support sockets so it angles away from the head of the bed The patient may grasp the labor bar where it s comfortable for her Affinity III Rev 000 USER MANUAL 27 USER MANUAL 7 8 Pushing with Calf Supports To Adjust e Adjust the head of the bed to approximately 30 by pressing the Head Up control e Place the patient s legs on the calf supports The patient may pull back on her knees without the need for the staff to assist her e Lower the foot section if desired 7 9 Epidural Spinal Lateral Approach e Lower and t
45. use of overlays Seat Support Enables the patient to tailor her own comfort level Provides pelvic support to improve practictioner access and visibility during deliveries and repairs The firmness or softness of the surface is controlled by increasing or decreasing the amount of air contained in the air bladder Patient and staff controls are embedded in both siderails Lumbar Support Adds varying degrees of back support in the lumbar region to improve patient comfort both before and after delivery Fully inflated the lumbar support allows positioning of the patient s perineum out the V Cut for examination and delivery The maximum lumbar inflation from a flat position to a full position is 4 10 cm Auxiliary Outlet The two auxiliary outlets provide electrical power for future upgrade accessories Location The two 12 V AC 20 watt auxiliary outlets are located on both sides of the bed Affinity III Rev 000 15 USER MANUAL Hill Rom 5 2 Siderail Controls 5 2 1 Built In SideCom Communication System Controls Optional Every Affinity Three Birthing Bed with siderail controls is pre wired to accommodate the SideCom Communication System now or in the future The SideCom Communication System enables integration of the backlit nurse call entertainment radio and TV and lighting in the siderails The optional Universal TV is also available Built In Siderail Controls Patient and staff controls are embedded