Home

1 - Spectrum Medical X

image

Contents

1. Figure 9 3 Column Assembly 9 8 Column Assembly 112 5018G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 2 6100310 Axle Column Top 1 3 6202010 Double Diff Wheel 1 4 6504310 Top Cover 1 5 6800199 Thrust Washer 2 6 031 5001P1 Shipping Tag 1 7 112 0756G1 Shipping Bracket Assembly 1 8 112 5016G1 Counterweight Assembly Refer to 1 Section 9 7 for Breakdown of Assembly 9 112 5017G1 Vertical Carriage and Frame 1 Assembly Refer to Sections 9 8 amp 9 9 for Breakdown of Assembly 10 114 5011P1 Column Base 1 11 203 5006P1 Cover Vertical Carriage 1 12 210 5011P1 Side Cover 2 13 234 5001P1 Bar Vertical Carriage Stop 1 14 236 5012P1 Wall Bracket Med Wht 1 15 240 5005P1 Spacer Cover 4 16 301 5003P1 Column Wall Stand 1 17 301 5001P1 Support Pulley Mounting 1 18 400 0021P1 Bearing Ball 2 19 400 5001P1 Bumper 1 21 422 5001P2 Screw Metric M4 X 8mm 6 22 422 5003P1 T Slot Nut 5 16 18 5 24 731 10 01200000 Retaining Ring External 12mm 2 Dia 25 751 00 252075
2. I O D E F G I J REVISIONS DESCRIPTION DATE APP D B jProduction Release 8 C BOM Change D BOM Change E Remove R12 F Schematic Corrections VREF Ho 1 8 oc Vec E nya 24V 7 HEBO op Gnd R3 4k HF120 3 6 15K 0A Rt Ct R4 Q1 a4 oa ue r 3 U2 C5 IS 1K F MTP2955 MC33039 4 220nF a d 7 J1 100k R6 aa m ra 1K MTP2955 End Yellow c2 S 8 Bas 8 Brown 9 TP3 R7 41K M 19 Black i SE 11 Red NKA 1 P 1 MTP3055E 12 HEADER 1K C3 MTP2955 470 5 1 w S R11 1 BRAKE MTP3055E or Re FOR REM R9 1 470 D1 D3 D2 9 2 a lt 0 TW d 42V 1N5819 1N5819 1N5819 MEnable vc E I m R18 24V DS S D VREF RefOut VCC Bu ets E RIG ela Gi C4 Soul a 4 7K 5V o1 400048 C13 BRIDGE ERR 7812 U1 K 4 7K i CON8J2 ERR NN NN FAULT 1 gt 1 lt C6 i ds Zou Ni gt ISO3 4 24VREF RLY S 13 de Di d MC33035 en 2 cs MCT62 24VAC S NA JP4 R17 1M 100uF 100u lo 12VAC L_ gt one R21 gt 12VREFL OH R22 super EES HDR 2X2 8 10k PROGENY Inc 1 THIS DRAWING IS THE PROPERTY OF AND x APPROVALS Fabrication 10 06301 CONTAINS INFORMATION PROPRIETARYTO Assembly Dwg 10 08000 PROGENY INC THIS DRAWING SHALL NOT BE REPRODUCED
3. INDICO 100 SERIES H V TANK ANODE H V CABLE K 3375 60 d CATHODE H V CABLE K 3375 60 10 AWG X RAY TUBE GROUND CABLE 126 520261 65FT ROTOR CABLE 15 CND 22 AWG HORIZ SID CABLE 5187 134 10 60FT SHH 40 C 22 GA SH 70 08166 65FT FOR AUTO COLIM AO 2 C 22 GA CABLE 126 5206G1 60FT SEE NOTE 5 2 THERMSW SEE NOTE 2 1 THERMSW SEE NOTE 19 OTC 3 OVERHEAD TUBECRANE TUBE 2 CUT OFF THE JUMPER FROM X020 uu TO x0 16 ON APOLLO AND CONNECT ROOM INTENTA RED WIRE TO XO 16 BLK WIRE TO X0 20 BLK Az x mum CABLE 126 525761 CABLE 126 5258G1 CABLE 126 5259C1 RED NO NS wor ENI T rj IET EE ES d d d RN 24VU al Bier B 3e so GL 3e L 5 BLK c c c DO 40 LSID 3 4L 4 Z ORG a ROOM I F PCB ep CABLE 126 525461 E CABLE 126 525601 se sw 5 36 so sw 4 72 so sw 1 ciel ser iso Hren sols Tii i um ncs Se SI Bk Bia 72 iso S Haik 12 2 733184 BLK RED HORZ SID SW ASM TN WLC 6 COM 1 WBKY INTERLOCK PARK LED 6136 134 11 5 4 WBKY_INTERLOCK TO BE MOUNTED ON THE OTC 3 OVERHEAD COVER BLK 3 BLK aur SRN 5 MAKE CONNECTION Se RED PROGRAM GENERATOR 1 TB1 BLK TO ACTIVATE V 1 AUX INPUT TB1 4 5 182 seul IZ ES AUX INTERLOCK BUCKYl SEL 40 22 AWG HOOK UP WIRE 0 e 75 BRN IBUCKY1_SEL CUT FROM 44109 BLU CB2 2 54 BLU ROOM INTERFACE 9 RED BLK RED ji s F 72 PNK PCB_JUMPERS 8 BLK B IEAA WALL POSITION ZICOLLIM INT TUBE S
4. P TO THE MAXIMUM WEIGHT SHOWN 3 ENGINE ECORD FOR THE BUILDING SHALL PROVIDE SUPPORT STRUCTURE DESIGNE SUPPORT WEIGHTS AND FORCES SHOWN IN ADDITION TO ALL OTHER LOADS OTES SHEETS 2 APPRO VE D Fixed Equipment Anchorage Office of Statewide Health Planning and Development a di Ps OPA 1818 on Tuesday April 1 2008 yy Anthony R Pike J 916 654 3362 Figure 1 5 Wall and Floor Mounted 1 10 Seismic Anchoring Specifications VS 200 Wallstand Installation Operation amp Service Manual E A e s EQUIPMENT ANCHORAGE amp SEISMIC ENGINEERING www equipmentanchorage com DEL MEDICAL VS 200 VERTICAL WALLSTAND pr M DC FREE STANDING SEISMIC ANCHORAGE SLAB ON GRADE 5 16 THICK STEEL I BASE PLATE de AND BRACING BY MANUFACTURER G Ger O a d G G NT 200 LBS LEQ a D dl PLAN AT BASE i USE 2 3 6 HILTI KBAIII EXPANSION ANCHORS MIN EMBED 3 50 ul i PLAN AT WALL PLATE ELEVATION NOTES ANCHORAGE DESIGN PER 2001 CALIFORNIA BUILDING CODE SECTION 1632A AND HAVE BEEN FACTORED TO REPRESENT WORKING DESIGN LOADS NOT ULTIMATE HORIZONTAL FORCE Wi Oo Ca 66 lp 15 ap 25 Rp 30 35 O GHT I A MAXIMUM THIS PRE APPROVAL ENCOMPASSES ALL WEIGHTS ONN VERTICAL
5. IDR 1 3 Lui ION CHAMBER lt 25D 40 VSID 22D 40 HSID 21D SIDCOM 20D 72 HSID TB101B 120 VAC POWER GRN RED 3 C 24GA SID CABLE 126 522261 SOFT 126 5247G1 60 FT GRN YEL 120 240 VAC 3_ND SID CABLE POWER 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 9 CND SHLD ION CHAMBER CABLE 75035 45 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 120 VAC POWER 9 END SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 22 CA CASSETTE SENSE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 DEL MEDICAI CPI CMP EV650 FMTS VS 200 LIN IV 034 5077S SHT 19 REVISION 2 ECN 8003 10 30 07 OTC 3 HOUSE HN CABLE K 3375 60 HN CABLE K 3375 60 10 AWG X RAY TUBE GROUND CABLE 126 5202G1 65FT 5 CND 16 AWG ROTOR CABLE 126 5228G1 65 FT 15 CND 22 AWG HORIZ SID CABLE 5187 134 10 60FT INDICO 100 SERIES ANODE CATHODE H V TANK SHIFT MAIN COM GND THERMSW 1 THERMSW TUBE 1 40 C 22 GA SH 70 08166 65FT FOR AUTO COLIM 6 5 4 3 ADAPTER CABLE 126 522361 2 2 CND 22GA SID MONITOR CABLE
6. Figure Addendum 2C 1 Vertical Carriage Assembly Showing Weight cover 3 Addorremove counterweights to achieve smooth movement 4 Re install Carriage and Frame Assembly top cover with two screws removed in step two 5 Remove the cable tie that from the release brake Handle 6 Re check for proper brake operation when all covers and the CXDI 50 X ray Digital Camera System are installed 7 Proceed with alignment of the wallstand and receptor per Installation Instructions step 5 Chapter 2 page 2 5 Addendum 2C 2 Canon 50G Image Receptor Wallstand Installation Addendum Image Receptor Installation Varian Paxscan 4343R Image Receptor Installation This Addendum describes the Varian Paxscan 4343R Digital Imaging Receptor installation on the VS 200 Wallstand Tools Required 11 32 Nut Driver Diagonal Side Cutters Medium Phillips Tip Screwdriver Metric Hex Wrench Set Miniature Flat Tip Screwdriver 1 Unscrew top cover screws 1 in Figure Addendum D 1 and remove top cover 2 Figure Addendum D 1 Top Cover Removal Varian Paxscan 4343R Image Receptor Installation Addendum D 1 VS 200 Wallstand Installation Operation amp Service Manual 2 1 in Figure Addendum D 2 up and off wallstand Slide front cover Figure Addendum D 2 Front Cover Removal Only do steps 3 7 if your wallstand has an optional ION chamber automatic exposure control 3 Unscrew four cover
7. m CNL deg ELEVATING TABLE de Lei Gala vts sueer EM 90 eerie Sez Sat PROGENY BUCKY EE L z SE Yal DEI e Ll 4 e OF IE P106 J106 TB102 AEC CABLE 124 0126G J202 lt ION CHAMBER PSD AU VSID e4D 40 VSTDR PD A0 HSID 21D SIDCOM POD 7e HSID 3 CND 18 AWG POWER CABLE RED BLK 120 230 240 3 CND 18 AWG POWER CABLE INCOMING POWER DISCONNECT 3 CND 18 AWG POWER CABLE GRN YEL VERT SID COLLIMATOR CABLE 70 09103 HORIZ SID COLLIMATOR CABLE 70 09105 6 C 18 GA TABLE BUCKY CBL_126 5050G3 65FT TABLE BUCKY CASSETTE PRESENCE CABLE 07 09102 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 G WALL BUCKY CBL 126 5089G1 65FT WALL BUCKY CASSETTE PRESENCE CABLE 07 09101 9 CND SHLD ION CHAMBER CABLE 75035 45 TABLE 1 P1065 PIN COLOR SIGNAL P106 NOTES COIL CORD 1 7 PIN CONNECTOR P N 651 5033P7 FOR THE COLLIMATOR TABLE CASSETTE PRESENCE CABLE SUPPLIED WITH THE TABLE 2 TERMINATION OF THE CONNECTOR P106 SEE TABLE 1 GRN 40 H SID BLK H SID COMMON oe rs SEIN DEL MEDICAL ec eas an INTERCONNECT EV650 W FCMT K 860 UNIVERSAL OPERATOR CONSOLE cv lufola a EXPOSURE HAND S
8. Figure 9 10 Mounting Frame Canon 40 Digital Receptor 9 24 Mounting Frame Canon 40 Digital Receptor 112 5403G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 1 100012P3 Trim Screw 10 32x3 8 2 100012P6 Trim Screw 6 32x5 16 3 203 5151P1 Side Plate 1 4 203 5152P2 Bottom Plate 1 5 203 5153P2 Top Cover 1 6 203 5155P1 Bracket VS 200 Canon 40 1 7 203 5155P2 MNL Bracket VS 200 Canon 40 1 8 407 5036P1 Open Closed Bushing 1 9 703 00 06001201 MNL Screw SHCS M6x12 4 10 786 50 25000011 MNL Washer SPLITLK STD 1 4 4 Table 9 11 Mounting Frame Canon 40 Digital Receptor Mounting Frame Canon 40 Digital Receptor 112 5403G1 9 25 VS 200 Wallstand Installation Operation amp Service Manual 9 14 Mounting Frame Canon 50 Digital Receptor 112 5404G1 Figure 9 11 Mounting Frame Canon 50 Digital Receptor 9 26 Mounting Frame Canon 50 Digital Receptor 112 5404G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 1 100012P3 Trim Screw 10 32x3 8 12 2 214 5016P1 Top Cover VS 200 Canon 50 1 3 214 5017 MNL Bottom Cover VS 200 Canon 50 1 4 214 5018P2MNL Short Side Cover VS 200 Canon 50 1 5 214 5018P1 MNL Long Side Cover VS 200 Canon 50 1 6 306 5011P2 Front Panel Canon
9. TICAL FORCE W 0 351 2 CENTER OF GRAVITY C G WEIGHT I5 A MAXIMUM THIS PRE APPROVAL ENCOMPASSES ALL WEIGHTS UP TO THE MAXIMUM WEIGHT SHOWN 2 ENGINEER OF RECORD FOR THE BUILDING SHALL PROVIDE SUPPORT STRUCTURE DESIGNE PPORT WEIGHTS AND FORCES SHOWN IN ADDITION TO ALL OTHER LOADS OTES SHEETS 2 APPROVED Fixed Equipment Anchorage Office of Statewide Health Planning and Development OPA 1818 Tuesday April 1 2008 TIIN Anthony R Pike 2 J 916 654 3362 Figure 1 7 Free Standing Bolts Through Floor 1 12 Seismic Anchoring Specifications VS 200 Wallstand Installation Operation amp Service Manual 1 8 Abbreviations AWG Btu SE CE cm C R S F ga hPa inHg Kg Lb max min PBL Sq Ft Sq M UL Percent American Wire Gauge British Thermal Unit Degree Celsius Communaut s Europ ennes Centimeter Cold Rolled Steel Degree Fahrenheit Gauge Hecto Pascal Inches Mercury Kilogram Pound Meter Maximum Minimum Millimeter Positive Beam Limitation Square Foot Square Meter Underwriters Laboratories Abbreviations VS 200 Wallstand Installation Operation amp Service Manual 1 9 Overhead Lateral Hand Grip Option Figure 1 8 Overhead Lateral Hand Grip Option Note The optional overhead lateral hand grip option will reduce the vertical travel length With the handle in it s u
10. 8 4 Chapter 9 Illustrated Parts List 9 1 Orderirig Parts chair 9 1 9 1 1 To Order by Telephone ire bes See ed eRe weer SOR 9 1 91 2 To Order Dy Bak 9 1 22 How to Use This Parts List css vex ox corr EE ESPERE 9 2 9 2 1 General Part Numbers 9 2 9 3 Commonly Ordered Parts nunua runnner 9 3 9 4 Overall VS200 Wallstand Assembly 110 5010G1 9 4 9 5 Final Trim Kit 112 5188G1 9 6 9 6 Column Assembly 112 5018G1 9 8 9 7 Counterweight Assembly 112 5016G1 9 11 9 8 Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 1 of 2 9 12 9 9 Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 2 of 2 9 14 9 10 Grid Cabinet Assembly 112 0597 G1 9 18 9 11 PBL Tray Bracket Assembly 5500 2855 9 20 9 12 Mounting Frame CMT Digital Receptor 112 5402G1 9 22 9 13 Mounting Frame Canon 40 Digital Receptor 112 5403G1 9 24 9 14 Mounting Frame Canon 50 Digital Receptor 112 5404G1 9 26 9 15 Varian Panel Cabinet Assembly 112 5500 9 28 9 16 Varian Cabinet Grid Tray Assembly 112 5501 9 30 9 17 Grid Detection Switch Assembly 112 5503 9 31 9 18 Varian Cabinet Loose Parts Kit 112 5504 9 33 9 19 Cooling Fan Assembly 112 5505 9 35 9 20 Toshiba Pane
11. ZAVDCRET 24VDC 24VAC ZAVACR 2 3 4 POWER SUPPLY K 843 PS 120 24 B1 1 82 2 B3 3 B4 N BB L B6 G TB LONC T7 SOURCE Te Ts RosS TAZRET T3 T2 rt q4 1 E AEC GARC PCB 124 012662 gt GRN YEL J1 lt BLK 126 5206 80FT GE 2 FD BRN T EIS Eb uns Ska OEC SHLD GND OUTP J2 lt T SIUS pira TES s abr PIENO E EET cu GU ION CHAMBER BLK GRN 3 CND 18 AWG POWER CORD 052449 69FT 2 C 22 GA CABLE BLU GRN YEL 3j 126 020462 COLLIMATOR HEAD MANUAL COL MOTHER PCB 124 0106S J12 6 C 18 GA TABLE BUCKY CBL126 505063 65FT 6 C 18 GA WALL BUCKY CBL 126 5089G1 ELEVATING TABLE EV 650 VLA BUCKY PBL al OPTIONAL S COLLIM DIFF TUBECRANE SID POT DIF SID POT 122 507661 122 504261 IE PROGENY BUCKY BRN TB102 J202 ION CHAMBER 1 NN 2 Y lt Ic PA lt T TB101
12. gt 126 5206 80FT GRN YEL GRN YEL NOTE PLEASE SEE PAGE 3C 5 OF CMP 200 MANUAL ABOUT BUCKY RUN ON W O COMMAND GRN YEL 7 SOURCE T6 rs cross T T2 T1 AEC PCB 737998 lt ION CHAMBER 3 CND 18 AWG POWER CORD 052449 69FT 2 C 22 GA CABLE COLLIMATOR HEAD MANUAL COL 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT ELEVATING TABLE EV 650 VILA BUCKY pak PROGENY BUCKY OPTIONAL COLLIM DIFF TUBECRANE SID POT DIF SID POT 122 507661 122 504261 BRN GRN HT LU CONTROL PCB TB102 J202 1 vy 1 2 oa Y ION CHAMBER ch jr DC RET L2 Li lt PE TB101B 25D 40 VSID 24D 40 VSIDR 22D 40 HSID 20D 72 HSID J203 T8 LNG 5V 120 VAC POWER BLK GRN YEL BLU BRN 2 C 22 GA CABLE 126 5206G1 60FT 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 120 VAC POWER
13. Figure Addendum D 33 Front Cover Installation Addendum D 22 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 45 Add counterweights 1 in Figure Addendum D 34 to balance wall stand movement Figure Addendum D 34 Counterweights 46 Reinstall top cover 1 in Figure Addendum D 35 Figure Addendum D 35 Top Cover Installation Varian Paxscan 4343R Image Receptor Installation Addendum D 23 VS 200 Wallstand Installation Operation amp Service Manual 47 Remove junction box cover 1 in Figure Addendum D 36 Figure Addendum D 36 Junction Box Cover Addendum D 24 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual Note All cables can be routed either through wall conduit port 1 in Figure Addendum D 37 or conduit tubing 2 48 Connect power cable 3 to power supply 4 49 If applicable connect optional ion chamber cable from generator to ion chamber cable 5 50 Connect Varian detector cable from Varian control unit to Varian detector cable 6 51 Route comm cable 7 through conduit to Varian control unit 52 Connect ground cable from generator to ground terminal 8 PS Industries lt j DETECTOR POWER SUPPLY i Figure Addendum D 37 Junction Box Connections Varian Paxscan 4343R Image Receptor Installation Addendum D 25 VS 200 Wallstand In
14. GND STUD BGL 3 CND 18 AWG POWER CORD 052449 60FT JUMPER OVER TABLE COLLIMATOR LOGIC LINEAR IV COLLIMATOR COLLIMATOR HEAD WALL BUCKY TABLE uer EXPOSURE VERTICAL BLK 1564 HOLD HORIZONTAL SID BREEZE FRE DO ABE BB REDI 56 1 Is zit x 2 CND COLLIM FXP HOLD CABLE 73 06525 40FT SUPPLY WITH COLLIMATOR 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 15 CND 22 AWG HORIZ SID CABLE 5187 134 10 60FT 6 C 18 GA WALL BUCKY CBL 126 5089G1 RT100 TABLE JUMPER THIS CABLE IS NOT NEEDED FOR THIS SYSTEM TB102 ION CHAMBER Ts cross T6 12 rt lt TS 120 VAC POWER 120 VAC POWER 2 C 22 GA CABLE 126 5206G1 60FT GRN YEL 22 GA CASSETTE PRESENCE CABLE 70 06525 40 FT SUPPLIED W COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 22 GA CASSETTE SENSE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 A REFER TO INTERFACE TABLE FOR CONNECTING CABLE ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING TERMINALS WITH 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE T
15. ROOM PCB INDICO 100 SERIES SHIFT MAIN COM GND THERMSW THERMSW TUBE 1 INTERFACE H V TANK od H V CABLE K 3375 60 OTC 3 HOUSE H V CABLE K 3375 60 10 AWG X RAY TUBE GROUND CABLE 126 520261 65 FT 15 CND 22 AWG HORIZ SID CABLE 5187 134 10 60FT 40 C 22 GA SH 70 08166 65FT FOR AUTO COLIM CATHODE 65FT 5 CND 16 AWG ROTOR CABLE 126 522861 ADAPTER CABLE 126 522361 5187 134 20 VERT 8 PIS 2 CND 22GA SID MONITOR CABLE SUPPLIED W COL 2 C 22 GA X RAY POS CABLE 126 5206G1 BOFT OTC s CONT SD Pce UT 124 5087 ES is 3 EXP HLDZ 2 EXP_HLD1 3 CND 18 AWG POWER CORD 052449 69FT E J7 ROOM F PCB 733184 Tet TBL POS IN TUBE POS IN 1 24vU J10 2 T TO CONTROL BOX EES DIE Pos our We 3lIPOS1 NBKY INTERLOCK DECH WBKY INTERLOCK cl Ead Sse HSE m INTERFACE TABLE PROGRAM GENERATOR 1 TO ACTIVATE 1 AUX INPUT TB1 4 5 TB2 AUX INTERLOCK BUCKYI SEL 1BUCKYl SEL E 8 ROOM INTERFACE ZCOLLIM INT PCB JUMPERS A 3 4 1 2 9 8 pa TB3 BKY START Boo ane SEHR Ri ORG SHIFT TS1 3 RED LEAD HEI Se 4 auc CONT RET YEL TEPNA TS1 5 QC TERM BRN
16. APX 525 625 DXR 30 X RAY GENERATOR ANODE 5 CND 16 AWG ROTOR CABLE 126 5228G 65FT 3 CND 18 AWG 70 08177 65 COLLIMATOR MANUAL 2 C 22 GA EXP INTRLK CABLE 126 5193G1 60FT 4 C 22 GA INTERLOCK BACKY CABLE 126 5213G1 65FT 2 C 22 CA X RAY POS CABLE 126 5206C1 80FT 3 CND 18 AWG POWER CORD 052412 60FT CONNECTOR PCBA 124 0115G1 OTC 3 OVERHEAD TUBECRANE DOOR INTRLK COLLIN INTRLK COMNON HEH P8 2 COM 3 WALL Y HES 2 xs TB2 3 xc PHASE MAN COMMON THERMAL SW THERM SW CON TB1 CBI 2 54 INTERFACE TABLE ROTOR GENERATOR CONNECT TO CONNECT TO CABLE TOSHIBA TUBE VARIAN TUBE BLK COM TS1 1 WHT LEAD RED MAIN TS1 2 BLK LEAD T EXP HLDZ 2 EXP_HLD1 BRN gt GND STUD CB2 2 5A gt BLU T4240 P10 2 T 3 TPOST GND SI RED EI 5A 250V WALL STAND h l Fer BE ORG PHASE TS1 3 RED LEAD VS 200 TOC CKT COMMON ir YEL TEMA TS1 5 QC TERM 24 vac Io TENVAC COM 24VL ut o E BLU TS1 6 QC TERM BRN GROUND GND GND SHIELD Ss GND GND 3 TABLE SELECT 2 TABLE FEEDBACK 3 1UVAC 4 CKT COMMON 117VAC_COM RED BRN BLU WHT GRN YEL GRN YEL 120 230 VAC 2
17. Y1 pi 12MHz les 12 eg Zon o ULN200 40106 11 Ger aen ULN20 40 10 Oo ISO4 2 SE C C A B C G H J I J 5V SW2 40106 Fault 8 da ET 2 E mI 3 SE i 4 w r 12vDC cru 3 45V 12VAC 3 DIP 8 L MAI 3 sy I L 12vDC AO sms AS BE La P D se RP3 P i E EN 38 s MATS C SEW 330uF MINI B Er X1 U11 E 6 S LYNN 100uF SS PO 4 L X2 E SIS Si PO 7 22 i RESET WE E TO P22 22 5 ho BEDA 1 27 19 57 Pe 5V CRLY 1 12 RO e Is 14 PSEN PSO 13 RXD inn d yea A 87C51 E 5Vo 40106 ULN2003 cs0 vec zl Et MODE SCL de GND SDA 8 9 5V 2814 jh RP1F 5V 10k d 2 RP1C uss eg 5 4 10k RP1 40106 ULN2003 A Oo THIS DRAWING IS THE PROPERTY OF AND CONTAINS INFORMATION PROPRIETARYTO PROGENY INC THIS DRAWING SHALL NOT BE REPRODUCED USED OR DISCLOSED WITHOUT THE PRIOR WRITTEN CONSENT OF PROGENY INC gg tdi ULN2003 J RP1G 10k SV APPROVALS DATE 1 S 3 EADER 3 PROGENY Inc DRN APP Assembly Dwg 10 08000 itle Bucky Control CH F K G H Size Document Number B 10 08001 Date 24470 EEE Fabrication 10 06301 Sheet of m
18. Figure Addendum 2A 2 CMT Left Right Corner Bracket Mounting 5 Slide the corner brackets and CMT receptor assembly onto the Carriage temporarily to check direction of wallstand brake handle and grid door orientation and Main Cable exit path Addendum 2A 2 CMT Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual The left right orientation of all should be appropriate for room workflow consistent with the following planning considerations Plan direction of power and signal cable so that during normal workflow movements persons or equipment in the room do not obstruct impinge kink or crush cable Provide sufficient cable slack to allow movement during the X ray patient setup process If necessary see the CMT manual to reverse the digital imaging receptor door and grid panel position The receptor has a label that explains its orientation as shipped Example a receptor labeled column left will open left From room plans or order requirements determine the left right functional orientation requirements of the Wallstand brake handle and digital receptor grid door opening The brake handle and grid door opening should be on the same side for the convenience of the operator If needed change the orientation of the brake handle according to Chapter 5 section 5 4 of this manual 6 Place the CMT receptor on a sturdy workplace to install internal wiring 7 Orient the direction of the wir
19. TB101B 25D 40 VSID 24D 40 VSIDR 22D 40 HSID 20D 72 HSID J203 s DC RET T5 CRS T8 LNG 5V 120 VAC POWER RED BLK GRN YEL GRN YEL BRN BLU 2 C 22 GA CABLE 126 5206G1_60FT 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 6 C 18 GA WALL BUCKY CBL 126 5089C1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 120 VAC POWER 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 9 END SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 NOTES INTERFACE CABLE 473780700 A REFER TO INTERFACE TABLE FOR CONNECTING CABLE ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING TERMINALS WITH 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE TABLE TO COMPLETE CONNECTION DEL MEDICAI PLEASE REFER TO CPI SERVICE MANUAL SUPPLEMENT 746028 FOR HOW TO CONNECT COLLIMATOR CABLE TO 24VAC CONTROL WALL STAND VS 200 TT 81 1 B2 2 B4 N BB L B6 G TB LONG T7 SOURCE T6 TS CROSS T47RET Ts TZ ri ION CHAMBER lt INDICO OTC 3 EV650 VS 200 MC 150 CONSOLE 034 5077S SHT 8 J8 GENERATOR INTERFACE REVISION 4 ECN 8003 10 30 07
20. 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 S NOTE A REFER TO INTERFACE TABLE FOR CONNECTING CABLE ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING TERMINALS WITH 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE TABLE TO COMPLETE CONNECTION INTERFACE CABLE 73780700 remove 2 1 4 PO TERMINALS FROM CABLE 126 5213G1 AND CRIMP ONE TERMINAL TO THE BLK LEAD OF CABLE DEL MEDICA 126 5050G3 CRIMP OTHER TERMINAL TO BRN LEAD OF CABLE 126 508961 MAKE THE CONNECTION AS SHOWN CONTROL TO DISABLE THIS OPTION CONNECT BLK LEAD OF CABLE 126 5050G3 DIRECTLY TO J4 6 ON GEN CONNECT CPI CMP OTC 3 EV 650 VS200 MC 150 console BRN LEAD OF CABLE 126 5089G1 DIRECTLY TO J2 6 ON GEN 034 5077S SHT 1 J8 GENERATOR INTERFACE REVISION 4 ECN 8003 10 30 07 OTC 3 HOUSE H V CABLE K 3375 60 DN CABLE K 3375 50 10 AWG X RAY TUBE GROUND CABLE 126 5202G1 65 FT 15 CND 22 AWG HORIZ SID CABLE 5187 134 10 60FT CPI CMP 200 SERIES ANODE CATHODE H V TANK 65FT 5 CND 16 AWG ROTOR CABLE 126 5228G1 40 C 22 GA SH 70 08166 65FT FOR AUTO COLIM 2 C 22 GA EXP HOLD CABLE POT A C 22 GA BUCKY INTERLOCK CABLE 126 521361 2 C 22 GA X RAY POS CABLE _126 5206G1_80FT 126 52266G1 SOF
21. Addendum Image Receptor Installation Canon 40EG Image Receptor Installation This Addendum describes the Canon CXDI 40EG Digital Imaging Receptor installation on the VS 200 Wallstand An exploded view of the VS 200 wallstand vertical carriage is shown below Figure Addendum 2B 1 Exploded view of the VS 200 Wallstand Vertical Carriage It is suggested that you perform all of the following steps in the Canon 40EG Installation procedure while all parts remain horizontal on the floor or workbench Lifting the combined assembled unit requires two people The following procedure makes numerous references to the Canon CXDI 40EG Installation and Maintenance Manual and this VS 200 Wallstand manual You may want to have both manuals available Canon calls the digital receptor a CXDI 40EG Imaging Unit or sensor Our terminology for digital imaging receptors is digital receptor and these digital receptors usually have a housing with them The left right orientation of all of the following should be the same Canon 40EG grid door release push button Vertical Carriage release brake handle Canon 40EG Image Receptor Installation Addendum 2B 1 VS 200 Wallstand Installation Operation amp Service Manual Mounting digital receptor to wallstand 1 Referto the Canon CXDI 40EG manual for information on how to access the receptor housing to install power image signal wiring and for cable routing path and mounting positions Se
22. Automatic Exposure Control This same configuration will also interface with Acoma Control X CPI Del Medical Gendex Electromed EMD Triton OEC Quantum Medical Imaging Sedecal Innerscan Summit Industries etc AID Compatible jumper configuration Switch Setting Defeat Power Supply Isolation SW1 1 ON Enable Alternate Field Selection SW1 2 OFF Low Active Commands SW1 3 OFF Start Integrate amp Field Selects SW1 4 ON Field Configuration A 2 B 1 C 3 SW2 1 3 5 6 amp 7 OFF Positive Output SW3 1 ON Wika Swezone Alternate configurations are listed below GE Fischer Varian Compatible jumper configuration Switch Setting Defeat Power Supply Isolation SW1 1 ON Enable Alternate Field Selection SW1 2 OFF High Active Commands SW1 3 ON Start Integrate amp Field Selects SW1 4 OFF Field Configuration SW2 1 5 amp 8 ON A 1 B 2 C 3 SW2 2 3 4 6 amp 7 OFF SW3 2 OFF GTR Labs Compatible jumper configuration Switch Setting Defeat Power Supply Isolation SW1 1 ON Enable Alternate Field Selection SW1 2 OFF Low Active Commands SW1 3 OFF Start Integrate amp Field Selects SW1 4 ON Field Configuration SW2 3 4 amp 7 ON A 3 B 1 C 2 SW2 1 2 5 6 amp 8 OFF GTR Labs fields 1 2 3 Positive Output SW3 1 ON SW3 2 OFF 61154 Caibration Instructions P N 69329 REV 17 March 2005 Page 6 2005 Advanced Instrument Development Inc Advanced Instrument Development Inc 1011 N 25
23. Generator Connections L SCOLLINTLK x COMMON PHASE COMMON T s THERMAL SW Figure 2 15 APX MPX ATC Terminals 2 14 Bucky Installation Instructions G1 G3 VS 200 Wallstand Installation Operation amp Service Manual TB4 FP10 0037 Figure 2 16 Anthem Terminals J4 Figure 2 17 CPI CMP Terminals Bucky Installation Instructions G1 G3 2 15 VS 200 Wallstand Installation Operation amp Service Manual TB7 JW3 TB11 TB9 LET DS mm oe MTE E Y TB2 For CPI Indico generators place a jumper between TB9 3 and TB11 2 Also place the jumper plug on JW3 between terminals 4 and 6 Figure 2 18 CPI Indico Terminals 2 16 Bucky Installation Instructions G1 G3 VS 200 Wallstand Installation Operation amp Service Manual 2 4 Automatic Exposure Control Installation Instructions AN Warning Turn off all electrical power to wallstand and all its peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Connect AEC cable 1 in Figure 2 19 to system AEC cable 2 Figure 2 19 AEC Cable Automatic Exposure Control Installation
24. H V CABLE K 3375 60 HV CABLE K 53575 60 10 AWG X RAY TUBE GROUND CABLE 126 520261 5 CND 16 AWG ROTOR CABLE 126 522861 65 FT ANODE CATHODE 65FT 40 C 22 GA SH 70 08166 65FT FOR AUTO COLIM ROOM INTERFACE PCB J7 SHIFT MAIN COM GND THERMSW THERMSW sasssa J4 DOOR_INT DOOR_INT slasa BKY2 RDY BKY2 RDY BKY2 RET BKY2 GND BKY2 OUT BKY2 STRT NOTE PLEASE SEE PAGE 3C 5 OF CMP 200 MANUAL ABOUT BUCKY RUN ON W O COMMAND GRN YEL GRN YEL t AEC PCB 737992 CONTROL PCB 65FT 9 CND 18 AWG CABLE SUPPLIED WITH FMTS JUMPER C 18 GA WALL BUCKY CBL 126 508961 LINEAR Il 2 COLLMATOR y COLLIMATOR amp e HORIZONTAL 29 omen WALL TABLE HEAD gt SD ae BUCKY ITA mea SERERE E AA ERO Paese mag Be gg x XB Za zs ds Za a 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 6 2 CND COLLIM EXP HOLD CABLE 73 06525 40FT SUPPLY WITH COLLIMATOR ELEVATING TABLE EV 650 BLK GRN 2 C 22 GA CABLE 126 5206C1 126 5247G1 60 FT GRN YEL 3 ND SID CABLE SI 9 LX vii nee PH a O O ki r IS PROGENY BUCKY e 3 OP
25. BLK 7 SOURCE can Fe ze T3 12 m 65FT 3 CND 18 AWG POWER CORD 052449 60FT 2 C 22 GA CABLE lt I AEC PCB 737992 ION CHAMBER LINEAR Il OVER TABLE COLLIMATOR COLLIMATOR LOGIC COLLIMATOR HEAD WALL TABLE BUCKY TS3 12 EXPOSURE LK 7531 1 H LD 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT RED 6 ZG 18 GA WALL BUCKY CBL 126 5089G1 15 CND 22 AWG HORIZ SID CABLE 5187 154 10 60FT 22 GA COLL EXP HOLD CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR JUMPER ELEVATING TABLE EV 650 B VIA BUCKY PBllo PROGENY BUCKY OPTIONAL COLLIM DIFF TUBECRANE SID P DIF SID POT iri 4122 507661 4122 504261 m z 8 CONTROL PCB ese S ERE 2 ifjs 3 EB ee C vus ls BOR PAN MM M SS aaa o gp NA ake als S ERR BRIAR S 120 VAC POWER 120 VAC POWER GRN YEL GRN YEL 2 C 22 GA CABLE 126 520661 60FT 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA TABLE BUCKY CBL 126 505063 65FT 6 C 18 GA WALL BUCKY CBL 126 5089C1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT
26. EE 1124 PRE BLU R 2 24VAC RE SA 240VAC Va COLLIM CONTIN SID POT GND STUD TUBE CRANE DIFFER SID CABLE 186 5161 60FT WALL STAND Vs 200 1 mA 3272 33 3 BA N BB L B6 G gt i GRNZYEL gt RED BLK GRN gt WHT RED TELNE T7 SOURCE T6 GRN WHT 9LERISS T3 T2 m ION CHAMBER 120 VAC POWER DCTM TUBE CRANE COLLIMATOR HEAD ASS ViLA Bucky ELEVATING TABLE LINEAR IV OVER TABLE EV 650 COLLIMATOR LOGIC w COLLIMATOR Sdt LOGIC e G A Gi PROGENY BUCKY POWER Ed WALL TABLE OPTIONAL DT BUCKY BUCKY TUBECRANE COLLIM DIFF DIF SID POT SID POT 122 5042G1 122 5076G1 ole alone D xxx ooo H RED BLK TS6 4 eben a iu KEE RED Tss eg J202 amp ION CHAMBER L Li PE 24D 40 VSIDR TB101B esDj40 VSID TB101A 22 D 40 HSID 210 SIDCOM 20D 72 HSID J203 120VAC POWER GRN YEL CABLE 126 5161 60FT 2 C 22 AWG COLLIM DIFFERENTIAL SID CABLE 126 5211 60FT 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT A C 22 GA CASSETTE SENSE CABLE 07 09101 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 45FT 120 VAC POWER 6 C 18 GA TABLE BUCKY CBL_126 50
27. Floor Mount Kit VS 200 Wallstand with digital receptor CMT 110 5010G4 Patient Hand Grip Overhead Lateral Full Line of High Quality Grids Floor Mount Kit VS 200 Wallstand with digital receptor Canon 40EG 110 5010G5 Patient Hand Grip Overhead Lateral Full Line of High Quality Grids Floor Mount Kit VS 200 Wallstand with digital receptor Canon 50G 110 5010G6 Automatic Exposure Control Patient Hand Grip Overhead Lateral Full Line of High Quality Grids Floor Mount Kit 1 2 VS 200 Wallstand Description VS 200 Wallstand Installation Operation amp Service Manual VS 200 Wallstand with digital receptor Varian Paxscan 4343R Automatic Exposure Control Patient Hand Grip Overhead Lateral Full Line of High Quality Grids Floor Mount Kit VS 200 Wallstand with digital receptor Toshiba FDX 4343R Automatic Exposure Control Patient Hand Grip Overhead Lateral Full Line of High Quality Grids Floor Mount Kit VS 200 Wallstand Description 1 3 VS 200 Wallstand Installation Operation amp Service Manual 1 3 VS 200 Wallstand Overview Patient Handgrip Cassette Tray Handle Cassette Tray Holder Bucky Column Release Brake Handle II geg Immer sias Varian Paxscan 4343 Regular Bucky 110 5010G1 CMT 110 5010G4 Canon 40EG 110 5010G5 Canon50G 110 5010G6 Figure 1 1 VS 200 Wallstand 1 4 VS 200 Wallstand Overview 1 4 Dimensions VS 200 Wallstand Installation Op
28. Floor Mount Kit Installation Instructions 8000 VS200 FMK Auto Tracking Kit Installation Instructions 8000 VS200 ATK Table 9 1 Commonly Ordered Parts Commonly Ordered Parts 9 3 VS 200 Wallstand Installation Operation amp Service Manual 9 4 Overall VS200 Wallstand Assembly 110 5010G1 Figure 9 1 Overall VS200 Wallstand Assembly 9 4 Overall VS200 Wallstand Assembly 110 5010G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 1 112 5188G1 Final Trim Kit See Section 9 5 for 1 Breakdown of Kit 2 112 5018G1 Column Assembly See Section 9 6 1 for Breakdown of Assembly 3 114 5021P1 Handrail Med Wht 2 4 753 40 19106210 Screw SHCS 10 32 X 5 8 8 5 785 11 19000011 Washer Flat 10 Narrow 8 6 126 5089G1 Cable Wallstand Bucky 1 7 112 5402G1 Mounting Frame for CMT Digital 1 Receptor See 9 12 for Breakdown of Assembly 112 5403G1 Mounting Frame for Canon 40 1 Digital Receptor See 9 13 for Breakdown of Assembly 112 5404G1 Mounting Frame for Canon 50 1 Digital Receptor See 9 14 for Breakdown of Assembly 112 5504G1 Mounting Frame forVarian 4343R 1 Digital Receptor See 9 15 for Breakdown of Assembly 112 5526G1 Mounting Frame for Toshiba 1 FDX4343R Digital Receptor See 9 20 for Breakdown of Assembly Table 9 2 Overall FCTS Tubestand Sheet Overall VS200 Wallstand Assembly 110 5010G1 9 5 VS 200 Wallstand
29. GRN YEL AEC GARC PCB 124 0126G BRN GROUND J5029K BLU COLLIM CONTIN SID POT GND STUD O SOFT 3 CND 18 AWG POWER CORD Ete MOTHER PCB 124 0106S COLLIMATOR MC 150 18 G TABLE BUCKY CBL 126 5050G3 65FT 18 GA WALL BUCKY CBL 126 5089G1 ELEVATING TABLE BARE EV 650 Z Xn FRISSSS wa sucer PBLES lof Maul Ei teles ned ser glo Z PROGENY BUCKY ARER 2 END SHLD ION CHAMBER CABLE 73035 45 x D z ziaaz a t GI fora L 6421 e UO elle zen a x E 5 G Beg S S z Bla gt dog Ee lt Sas FREE SE BEAR cess 9 Ra a KMS Bs age Ged zar s M aa E ale SERRES S GRNYEL 3 CND 18 AWG POWER CORD 120 VAC POWER 3 C 14 GA SU INCOMING POWER CABLE 6 C 18 G TABLE BUCKY CBL_126 5050G3 65FT S CND SHLD ION CHAMBER CABLE 73035 43 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 AEC CABLE 3124 0126G2 COIL CORD DEL MEDICAI APX DXR OPERATOR CONSOLE WALL BUCKY CABLE 126 5089G1 65FT WALL STAND VS 200 BIZI B272 B373 B4 N Eug B8 L lt ION CHAMBER 9 CND SHLD ION CHAMBER CABLE 75035 45 INTERCON
30. IEC 60601 2 32 EN60601 2 32 IEC60601 1 3 EN60601 1 3 EN60601 1 2 2000 Certified To CAN CSA C22 2 NO 601 1 No user serviceable parts Table 1 1 Specifications Refer to the Digital Image Receptor Documentation for specifications on that portion of the VS 200 Wallstand System Specifications 1 9 VS 200 Wallstand Installation Operation amp Service Manual 1 7 Seismic Anchoring Specifications UIPMENT ANCHORAGE amp SEISMIC ENGINEERING www equipmentanchorage com x VS 200 VERTICAL WALLSTAND WALL amp FLOOR MOUNTED SEISMIC ANCHORAGE DEE EN WALL FLOOR MOUNTED _325 SHALL DESIGN THE WALL WA 0 a STRUCTURE 16 GA 50 KSI MIN e a s X i 2 4 6 S M SCREWS ALL BACKING Se os C G WT 200 LBS USE 2 3 6 HILTI KB III EXPANSION ANCHORS MIN EMBED 2 Tw 220 LBS SCREN Via 43 LBS BOLT T Wan 28 LBS BOLT ELEVATION T T PLAN AT WALL PLATE NOTES I ANCHORAGE DESIGN PER 2OO CALIFORNIA BUILDING CODE SECTION 1632A AND HAVE BEEN FACTORED TO REPRESENT WORKING DESIGN LOADS NOT ULTIMATE HORIZONTAL FORCE Vy OTIW Ca 66 Ip 15 ap 1 0 Rp 3 0 VERTICAL FORCE W O35W 2 CENTER OF GRAVITY C 6 WEIGHT IS A MAXIMUM THIS PRE APPROVAL ENCOMPASSES ALL WEIGHTS
31. Service Manual 3 10 Completely Removing the Cassette Tray Periodic Maintenance 4 1 Periodic Maintenance Schedule Refer to the schedule below for information on when to perform periodic maintenance on the wallstand If the wallstand is equipped with one of the optional digital receptors also refer to the corresponding documentation for maintenance information on that part of the system Note Due to varying operating conditions the procedures listed below may have to be performed at greater or lesser intervals You may have to adjust intervals according to your wallstand s performance What to Do When to Do It Refer to Section Clean External Surfaces Every Week or as Required Cleaning External Surfaces on page 4 2 Inspect Counterweight Cable Every 6 Months Checking Counterweight Cables on page 4 3 Check Brake Function Every 6 Months Checking Brake Performance on page 4 4 Check Fasteners for Tightness Every 6 Months Checking Fasteners for Tight ness on page 4 5 Table 4 1 Periodic Maintenance Schedule Periodic Maintenance Schedule 4 1 VS 200 Wallstand Installation Operation amp Service Manual 4 2 Cleaning External Surfaces Tools Required cleaning wipes non abrasive hospital grade cleaner N Warning If the wallstand is equipped with a bucky AEC PBL or digital receptor make sure that power source to these components is locked out and tagged W
32. Service Manual 31 Reinstall covers 1 in Figure Addendum D 20 Figure Addendum D 20 Side Cover Installation Addendum D 14 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 32 Install cover 1 in Figure Addendum D 21 Figure Addendum D 21 Handle Side Cover Installation 33 Install cover 1 in Figure Addendum D 22 Figure Addendum D 22 Handle Front Cover Installation Varian Paxscan 4343R Image Receptor Installation Addendum D 15 VS 200 Wallstand Installation Operation amp Service Manual 34 Reinstall grid sensor 1 in Figure Addendum D 23 Figure Addendum D 23 Grid Sensor Addendum D 16 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual AN Caution Handle receptor with great care in the following steps It is very fragile and very expensive 35 Mount handles 1 in Figure Addendum D 24 on receptor 2 with screws 3 from bag removed in step 9 Figure Addendum D 24 Mounting Handles on Receptor 36 Place receptor on cart or stand in front of wallstand exactly as shown below Figure Addendum D 25 Receptor in Front of Wallstand Varian Paxscan 4343R Image Receptor Installation Addendum D 17 VS 200 Wallstand Installation Operation amp Service Manual 37 Connect cables from wallstand to receptor as shown below Figure Addendum D 26 Receptor C
33. USED OR DISCLOSED WITHOUT THE PRIOR WRITTEN CONSENT OF PROGENY INC DATE Bucky Control CHK S Document Number 8 10 08001 fi Q Date 1 OMAROS 17DECO 01MAYO2 COPPER DATE O3MAROS ADDED R5 R41 R42 R43 amp DS COPPER DATE 13DEC04 ADD RGND R37 R38 D18 amp U15 SAME AS 61154A EXCEPT R23 1800 R34 1500 R35 1000 2005 Advanced Instrument Development Inc Advanced Instrument Development Inc 1011 N 25th Ave Melrose Park IL 60160 U S A Phone 708 343 7777 www aidxray com Fax 708 343 7795 Three field lonization Chamber Calibration Procedure for The 61154 Pre Amplifier Board Assemblies The following adjustments apply to the calibration of a 61154A pre amplifier board for a stationary 3 fiel
34. i 9 Record of Revisions REVISION MISlOLYs show hie cele ayes al kee RS ii 1 List of Affected Pages seriea i ser E roeit Ee ii 2 Chapter 1 Introduction Amour EE pda pla E a a 1 1 1 2 VS 200 Wallstand Description 1 2 VS200 Wallstand with regular bucky 110 5010G1 1 2 VS200 Wallstand with digital receptor CMT 110 5010G4 1 2 VS200 Wallstand with digital receptor Canon 40 110 5010G5 1 2 VS200 Wallstand with digital receptor Canon 50 110 5010G6 1 2 VS200 Wallstand with digital receptor Varian 110 5010G7 1 3 VS200 Wallstand with digital receptor Toshiba 110 5010G8 1 3 1 3 VS 200 Wallstand Overview 1 4 LA DIMENSIONS sesto en dose lire afla i 1 5 1 5 Mounting Dimefsions ours eg eda the pod E 1 8 1 6 5pecifiCatlDBS Ee io ones 1 9 1 7 Seismic Anchoring Specifications 1 10 1 8 Abbreviations sn a gi 1 13 1 9 Overhead Lateral Handgrip Option 1 14 1 10 Installation of Optional Kits 1 15 VS 200 Wallstand Installation Operation and Service Manual Chapter 2 Installation 2 1 Pre installation Pre planning 00 00 0000 2 1 2X A Tools required u ua nn ep eR irte 2 1 2 1 2 X ray Room Pre plant Bg 2 1 2 1 3 Planning Orienting Brake Handle Grid Door and Imaging Cable 2 2 2 1 4 Digital Imaging Receptor Do
35. 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE TABLE TO COMPLETE CONNECTION 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 6 C 18 GA WALL BUCKY CBL 126 5089C1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 DEI M EDICAI CONTROL CONSOLE A REMOVE 2 1 4 PO TERMINALS FROM CABLE 126 5213G1 AND CRIMP ONE TERMINAL TO THE YEL LEAD OF CABLE 126 5050G3 CRIMP THE OTHER TO BRN LEAD OF CABLE 126 5089G1 MAKE THE CONNECTION AS SHOWN CPI INDICO EV650 OTC 3 LIN Il VS200 J8 GENERATOR INTERFACE TO DISABLE THIS OPTION CONNECT YEL LEAD OF CABLE 126 5050G3 AND BRN LEAD OF 126 5089G1 CABLE DIRECTLY TO TB2 5 ON GEN 034 5077S SHT 17 REVISION 3 ECN 8003 10 30 07 CPI CMP 200 SERIES ANODE CATHODE H V TANK ROOM INTERFACE PCB J7 SHIFT MAIN COM GND THERMSW THERMSW GRN RED J2 BKY1_RET BKY1_GND BKY1 OUT BKY1_STRT BKY1_RDY BKY1_RDY INT1 INTTR INT2 INT2R sas ofS GRN YEL J4 DOOR INT DOOR INT BNEBNRCONDES BKY2 RDY BKY2 RDY BKY2 RET BKY2 GND BKY2 OUT BKY2 STRT BRN WHT BLU RED NOTE PLEASE SEE PAGE 3C 5 OF CMP 200 MANUAL ABOUT BUCKY RUN ON W O COMMAND I AEC PCB 737992 CONTROL PCB 9 CND SHLD ION CHAMBER CABLE 75035 45 INTERFACE CABLE 73780700 J8 GENERATOR IN
36. 184mm E 50 Cp spy EDD Ce 13mm 2 82 3 25 1 9327 72mm 83mm 1 32 34mm 34mm o 2 ST VA TN Ss E HE SG co wb di N 4 2 x x al View B Not to Scale 8 13 1 330mm 11 25mm 279mm x 4 ew A E E PE N CRIS E 16mm 5 3 8 View A Not to Scale eat Figure 1 4 Mounting Dimensions 1 8 Mounting Dimensions 1 6 Specifications VS 200 Wallstand Installation Operation amp Service Manual Specifications Compatibility External Heat Generation The VS 200 wallstand is compatible with a wide variety of generators and tubestands It is intended to be used in a stationary diagnostic x ray configuration None Classification Class 1 Type B Aluminum Equivalent Beam Attenuation of the wallstands front panel is 0 7 mm Aluminum Equivalent or Less Temperature Limits Transit Storage Operating 40 F to 158 F 50 F to 95 F 40 C to 70 C 10 C to 35 C ingress of water Relative Humidity Limits Transit Storage 10 to 100 Operating 10 80 Non Condensing Atmospheric Limits 14 5 inHg to 30 74 inHg 500 hPa to 1060 hPA Weight wallstand with regular bucky 200 Ibs 91 Kg Degree of protection against the Ordinary Certifications or nitrous oxide Equipment not suitable for use in the presence of flammable anesthetic mixtures with air oxygen C Classified To UL 60601 1 IEC60601 1 EN60601 1
37. 3 8 8 12 46 170015P8 Screw BHMS 8 32 X 1 4 6 13 46 170012P39 Nut Hex KEPS 10 32 X 5 32 4 14 46 170012P35 Nut Hex KEPS 6 32 X 1 4 8 15 203 0263P2 Framework Plate 1 16 46 170015P19 Screw BHMS 6 32 X 3 8 4 17 407 0112P1 Nut Hex Acorn 6 32 8 18 407 0184P1 Grommet 1 19 46 170015P17 Screw BHMS SEMS 10 32 X 1 4 2 20 5500 3554 2 Bracket Stop 1 21 5500 3554 Bracket Stop 1 22 46 170015P14 Screw BHMS 8 32 X 3 8 2 23 46 220360P1 Cable Clamp CLN 1 8 Dia 2 Table 9 8 Grid Cabinet Assembly Grid Cabinet Assembly 112 0597G1 9 19 VS 200 Wallstand Installation Operation amp Service Manual 9 11 PBL Tray Bracket Assembly 5500 2855 i em lt Mi gt PEHBEBEDEII oi 1 2 10275 Figure 9 8 PBL Tray Bracket Assembly 9 20 PBL Tray Bracket Assembly 5500 2855 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 2 1417 0604 Spacer Receptacle 2 3 1417 0602 Amphenol Receptacle Assembly 1 4 1417 0464 Self Centering Stud 2 5 1417 0603 Insulator Receptacle 1 6 202 5056P1 Tray Bracket 1 7 760 22 19102511 Screw PPNHM 10 32 X 1 4 8 4455 0300 3 8 Sleeving 0 33 9 785 11 11000011 Washer Flat 4 X 9 32 10 4450 0252 Screw PBHMS 4 40 X 7 8 2 11 5500 2835 Plate 1 12 762 20 14208811 Screw PFHMS 6 32 X 7 8 2 14 1417 0468 8 Terminal Strip PBL Il 1 15 46 220360P3 Cable Clamp 1 4 Dia 1 16 4450 0154 Screw PPHMS Ty
38. 5A YEL ERMA 191 5 QC TERM BRN a BLU H Irene QC TERM BLU TB 25s BER BRN GROUND GND GND CM 3 GND F1 5A 250V w 4 EZ HES AH 2 GRN YEL SHIELD imc GND GND J9 24 Vac Ul 24VL o LLI N OTC 3 OVERHEAD TUBECRANE GND STUD 60FT WALL STAND GRN YEL 126 520661 GRN YEL GRN YEL RED RED GROUNI IT7 SOURCE AEC PCB 737992 CONTROL PCB GRN P WHT T GRN War 15 gR05S T3 T2 m 65FT 2 C 22 GA CABLE lt ION CHAMBER 3 CND 18 AWG POWER CORD 052449 60FT JUMPER OVER TABLE COLLIMATOR LINEAR IV COLLIMATOR COLLIMATOR HEAD TABLE BUCKY SID o POWER EXPOSURE HOLD 120v N G C 18 GA TABLE BUCKY CBL 126 5050G3 65FT RED rS 71 BLK 156 4 WH 6_ C_18 GA WALL BUCKY CL 126 5089G1 BL 6 2 CND COLLIM FXP HOLD CABLE 73 06525 40FT SUPPLY WITH COLLIMATOR 15 CND 22 AWG HORIZ SID CABLE 5187 134 10 SOFT ELEVATING TABLE EV 650 ILA BUCKY OPTIONAL COLLIM DIFF TUBECRANE SID POT DIF SID POT 122 507661 122 5042G1 J202 IO
39. 65FT 4 C 22 GA BUCKY INTERLOCK CABLE 126 5213G1 60FT 2 C 22 GA X RAY POS CABLE 126 5206G 80FT 3 CND 18 AWG POWER CORD 052449 69FT T TABLE 2 COM 3 WALL JB INTERFACE TABLE ROTOR GENERATOR CONNECT TO CONNECT TO CABLE TOSHIBA TUBE VARIAN TUBE BLK COM TS1 1 WHT LEAD RED MAIN TS1 2 BLK LEAD 1 24vU 2 T 3 TPOS1 J10 LOCK CTRL PCB 5284 135 08 1B1 ORG SHFT TS1 3 RED LEAD CB1 2 5A YEL LEET Ire QC TERM BRN CELO THERMAL BLU CBZ 2 58 HO VSIDT BLU GERWAL Ts1 6 QC TERM eee e BRN GROUND GND GND Zeie GRN YEL GND Sm SHIELD GND GND F1 54 250V 24 VAC 24VL ut OTC 3 OVERHEAD TUBECRANE GND STUD 60FT WALL STAND VS 200 1 BL B2 2 RI gt B4 N BB L B6 G 126 5206G1 GRN YEL RED BLK GRN dg WHT 5 RED TE7LONG 17 SOURCE 1 T6 GRN WHT 1SLEROSS Ts TZ rt ION CHAMBER 2 C 22 GA CABLE lt COLLIMATOR HEAD TABLE BUCKY 1 1 P WALL BUCKY N l BI o El 3 3 12 ExPOSURE BLK TS3 11 HOLD REDI ss 25 z ER ER 2_CND_COLLIM EXP HOLD CABLE 73 06525 40FT SUPPLY WITH COLLIMATOR 15 CND 22 AWG HORIZ SID
40. 65FT FOR AUTO COLIM ADAPTER CABLE 126 522361 5187 134 20 2 CND 22GA SID MONITOR CABLE SUPPLIED W COL ED PIS ROOM INTERFACE PCB J7 SHIFT MAIN COM GND THERMSW THERMSW J2 BKYT RET BKY1_GND BKY1 BKY1_STRT BKYT RDY BKY1_RDY INTI INTTR INT2 INT2R na Ao 3 J4 DOOR INT DOOR INT A CA BKY2 RDY BKY2 RDY BKY2 RET BKY2 GND BKY2 OUT BKY2 STRT BRN WHT BLU RED NOTE PLEASE SEE PAGE 3C 5 OF CMP 200 MANUAL ABOUT BUCKY RUN ON W O COMMAND 4 C 22 GA BUCKY INTERLOCK CABLE 126 5213G1 2 C 22 GA X RAY POS CABLE 126 5206G1 80FT SOFT TABLE 8 2 cow WALL A END 18 AWG POWER CORD 052449 69FT OTC 3 CONT SID PCB 124 5087 E HESS J10 GT S TPOS1 TUBE POS IN EES DIF Pos our W 5V TO CONTROL BOX E MONITOR Un EIS LK Bl GER Ein D I J2 1 INTERFACE TABLE SEA ROTOR GENERATOR CONNECT_TO CONNECT TO CABLE TOSHIBA TUBE VARIAN TUBE BLK COM TS1 1 WHT LEAD LOCK CTRL PCB 5284 135 08 IN LINE CONNECTOR GRN BLK RED BRN DIF SID CABLE 5187 135 03 461 RED MAIN TS1 2 BLK LEAD ORG SHIFT TS1 3 RED LEAD TB1 14 ru 7 40 vsiD2 15 IT CB1 2
41. 9 10 N J o Sid 3 lo P PPP AB OI a xus EEEIS 8 zs q es asa al a te wld J12 E al 215 er sm 3 x o 3 5 va lt z l ME al wis EI alu al 2 2 Si Glo S lt a SI lg e s N Qi SR N INTERFACE BOARD oi s o 120 VAC J4 POWER 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 20017353 9 CND SHLD ION CHAMBER CABLE 20017353 NOTES 1 DISCONNECT AND ISOLATE TERMINAL FROM RAIL SWITCH ASSEMBLY 5136 134 11 DISCONNECT WIRES 126 5205 FROM J2 CONNECTOR OF LOCK CONTROL PCB CONNECT GREEN AND BLACK WIRES TO J12 PIN 1 AND 3 AS SHOWN ISOLATE WHITE ORANGE AND RED WIRES 2 REMOVE CABLE 126 5191 CONNECTED TO J12 CONNECT THIS CABLE TO J2 AS SHOWN INTERFACE CABLE 90001400 DEL MEDICAI CPI INDICO APOLLO OTC 3 LIN II VS200 mue 034 50077S SHT 26 REVISION 0 ECN 8003 11 07 07 GENERATOR INTERFACE BUCKY PRINTED CIRCUIT BOARD MOTOR BLDC EXP HOLD 1 EXP HOLD 2 START lt AC N wht AC blk lt F1 FUSE 3 4A SW DPDT TRANSFORMER T1 c2 1000uF F3 PROGENY Inc BUCKY CONECTION DIAGRAM 120 240 v MODELS Size Document Number lt Doc gt DateWed Dec 10 1998 heet FUSE 1A F2 Power Supply Board 5V R2 POSTTION 200 A C so E EE SX 107 HEADER 4X2 BRAKE lt FOR REV lt lt MEnable 5V
42. CABLE 5187 134 10 60FT ELEVATING TABLE ELL EV 650 ZA SIZE w eee see ele SOR SISI Poca sucr OPTIONAL BREZZA COLLIM DIFF TUBECRANE SID POT DIF SID POT 122 507661 122 504261 TB102 J202 ION CHAMBER TAZ 1 3 avi fut m CONTROL PCB lt 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 6 C 18 CA TABLE BUCKY CBL 126 505063 65FT TB101B 25D 40 VSID 24D 40 VSIDR 22D 40 HSID 20D 72 HSID J203 120 VAC POWER 120 VAC POWER RED BLK GRN YEL BRN BLU 2 C 22 GA CABLE 126 5206G1 60FT 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 120 VAC POWER 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 9 END SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA WALL BUCKY CBL 126 508961 65FT 22 CA CASSETTE SENSE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 NOTES INTERFACE CABLE 473780700 A REFER TO INTERFACE TABLE FOR CONNECTING CABLE ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING TERMINALS WITH
43. FORCE W 2 CENTER OF GRAVITY C G UP TO THE MAXIMUM WEIGHT SH ENGINEER OF RECORD FOR THE BUILDING SHALL PROVIDE SUPPORT STRUCTURE DESIGNED JO SUPPORT WEIGHTS AND FORCES SHOWN IN ADDITION TO ALL OTHER LOADS OTES SHEETS 1 2 APPROVED Fixed Equipment Anchorage Office of Statewide Health Planning and Development OPA 1818 on Tuesday April 1 2008 Ne A UE Anthony R Pike 916 654 3362 Figure 1 6 Free Standing Expansion Anchors Seismic Anchoring Specifications 1 11 VS 200 Wallstand Installation Operation amp Service Manual www equipmentanchorage com E A SE EQUIPMENT ANCHORAGE amp SEISMIC ENGINEERING DEL MEDICAL VS 200 VERTICAL WALLSTAND FREE STANDING D verre SEISMIC ANCHORAGE UPPER FLOOR 5 16 THICK STEEL BASE PLATE T AND BRACING BY MANUFACTURER o 93 Ge uy d J CG NT 200 LBS EQ EG PLAN AT BASE j E UP USE 2 3 8 BOLTS THRU FLOOR W z 2 X 2 X 4 X l 5 AT EACH BOLT AT UNDERSIDE OF FLOOR 50 2 EI Tux 2244 LBS BOLT la Mux 220 LBS BOLT T ELEVATION T T PLAN AT WALL PLATE NOTES AND HAVE BEEN FACTORED TO REPRESENT WORKING DESIGN LOADS NOT ULTIMATE HORIZONTAL FORCE M ITIN Ga 66 lo 15 ap 25 Rp 3 0 R
44. Figure 2 4 Tilted Pattern With the collimator still pointed towards the wallstand move the crane through its full in out range of motion If the collimator pattern shifts up and down as shown below adjust the angle of the wallstand until this effect goes away Figure 2 5 Up Down Adjustment 2 6 Installation VS 200 Wallstand Installation Operation amp Service Manual AN Caution It is very important that you do the following steps thoroughly and accurately or the grid in the wallstand will not work correctly If the wallstand is not properly rotationally aligned with the x ray tube dark bands will appear on the film after exposure as shown below Figure 2 6 Effects of Improperly Aligned Wallstand Installation 2 7 VS 200 Wallstand Installation Operation amp Service Manual Read steps 11 15 before doing them 10 Turnoff room lights 11 Turn on collimator light Make sure collimator pattern is centered on wallstand 12 Place a mirror on the face of the wallstand just above it s centerline as shown in Figure 2 7 Make sure that the bottom of the mirror is parallel with the centerline and not crooked as shown in Figure 2 8 Figure 2 7 Mirror Placement Figure 2 8 Proper Mirror Alignment Note The Canon50 does not have the rectangular boxes as shown in Figure 2 8 above See the Canon 50 manual for alignment procedures 2 8 Installatio
45. GND 126 520261 65FT 5 CND 16 AWG ROTOR CABLE 126 5228G 65FT 3_CND_18 AWG 70 08177 65 COLLIMATOR MANUAL 2 C 22 GA EXP HOLD CABLE 126 522661 60FT A C 22 GA BUCKY INTERLOCK CABLE 126 5213G1 60FT 2 C 22 GA X RAY POS CABLE 126 520661 80FT H V AUXILIARY PCB J7 SHIFT MAIN COM GND THERMSW THERMSW OTC 3 OVERHEAD TUBECRANE GRN YEL 1 ve 2 3 WALL INTERFACE TABLE ROTOR GENERATOR CONNECT_TO CONNECT TO CABLE TOSHIBA TUBE VARIAN TUBE BLK COM TS1 1 WHT LEAD MAIN TS1 2 BLK LEAD J11 24VAC 24VAC 24VDC 24VDC RET TB1 CB1 2 5A TTEXP_HLDZ 2 EXP_HLD1 BRN Be gt CB2 2 5A GND STUD BLU 1 24vU A10 2 1 3 TPOS1 LOCK CTRL PCB 5284 135 08 gt GND ORG sur ts1 3 RED LEAD FIT 54 2507 J2 YEL HAN 151 5 QC TERM ASO 10 BKY1_RET THERMAL SIS BLU MA Trei QC TERM 8 BKY1 OUT 7 BKYT STRT BRN GROUND GND GND 6 BKY1 RIOT 5 BKY1_RDY SHIELD GND GND 4 INTI 3 INTIR 2 INT2 1 INT2R J4 DOOR INT DOOR INT e BKY2_RDY BKY2_RDY BKY2 RET BKY2 GND BKY2 OUT BKY2 STRT WALL STAND VS 200 1 WHT BLU RED B171 82 2 B3 3 B4 N BB L B6 G
46. ICX series ion chambers Use the master gain adjustment to match the overall chamber sensitivity to that of the other stationary chambers connected to the system Note that the master gain adjustment is a multi turn potentiometer A clockwise adjustment to the master gain potentiometer will increase the sensitivity of the chamber causing the length of the exposure mAs to decrease 61154 Caibration Instructions P N 69329 REV 17 March 2005 Page 2 O 2005 Advanced Instrument Development Inc Advanced Instrument Development Inc 1011 N 25th Ave Melrose Park IL 60160 U S A Phone 708 343 7777 www aidxray com Fax 708 343 7795 Make exposures and process the films Adjust the master gain for the desired optical density Make the master gain adjustment for each stationary chamber being installed 61154 Caibration Instructions P N 69329 REV 17 March 2005 Page 3 2005 Advanced Instrument Development Inc Advanced Instrument Development Inc 1011 N 25th Ave Melrose Park IL 60160 U S A Phone 708 343 7777 www aidxray com Fax 708 343 7795 Field Balance Check Using the AEC post exposure mAs display or other calibrated mAs meter check the individual fields to see that they are balanced that is that they produce the same mAs reading If mAs readings are not stable from exposure to exposure for an individual field then it will be necessary to expose films and make these adjustments based upon optical de
47. Installation Operation amp Service Manual 9 5 Final Trim Kit 112 5188G1 Figure 9 2 Final Trim Kit 9 6 Final Trim Kit 112 5188G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 4 210 5013P1 Middle Cover 1 7 210 5015P1 Bottom Cover 1 8 214 5012P1 Top Cover 1 10 210 5008P2 Trim Bar Spacer 1 12 240 5009P1 Bar Trim 1 18 5500 0494P2 Panel Front Bucky Silk 1 Screened 20 202 5003P1 Bracket Cover Mounting 4 21 232 5001P2 Spacer Top Cover 2 22 100012P3 Screw Trim 10 32 X 3 8 6 23 100012P7 Screw Trim 6 32 X 1 2 2 24 751 02 19102511 Screw HHMS 10 32 X 1 4 4 25 757 41 19103310 Screw SHSSCP 10 32 X 3 8 2 26 760 22 14205011 Screw PPNHMS SEMS 6 32 X 1 2 D 27 760 22 19103111 Screw PPNHMS 10 32 X 5 16 6 28 642 0018P10 Standoff 6 32 X 9 16 2 30 408 5099P2 Label Del Med Logo 1 Table 9 3 Final Trim Kit Final Trim Kit 112 5188G1 9 7 VS 200 Wallstand Installation Operation amp Service Manual 9 6 Column Assembly 112 5018G1
48. Instructions 2 17 VS 200 Wallstand Installation Operation amp Service Manual 2 Connect other end of AEC cable to J2 of generator in locations shown in Figure 2 21 through Figure 2 23 3 After installing any remaining options calibrate the ION chamber according to the ION chamber manual included in Chapter 8 of this manual and according to the generator manual Note The A B C configuration for the ION chamber shown below is for right hand loaded wallstands Left hand loads are the opposite Figure 2 21 CPI CMP AEC Cable Hookup Point 2 18 Automatic Exposure Control Installation Instructions VS 200 Wallstand Installation Operation amp Service Manual Figure 2 22 CPI Indico AEC Cable Hookup Point Figure 2 23 APX MPX AEC Cable Hookup Point Automatic Exposure Control Installation Instructions 2 19 VS 200 Wallstand Installation Operation amp Service Manual 2 5 Automatic Cassette Size Sensing Installation Instructions AN Warning Turn off all electrical power to wallstand and all its peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Connect wallstand PBL cable 1
49. POWER SUPPLY HOWN FOR REFERANCE W FRONT COVER REMOVED FOR CLARITY Figure 9 20 Toshiba Panel Junction Box 112 5528G1 9 40 Toshiba Panel Junction Box 112 5528G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 1 204 5059P1 Enclosure Power Supply 1 2 204 5060P1 Cover Enclosure 1 3 204 5056P1 Bracket Cable Entrance 1 4 643 5002P1 Hose 1 ID Mushroom 5 5 408 5039P1 Label Earth Ground 1 6 100012PB Screw Trim 8 32 X 3 8 4 7 784 12 19100011 Nut KEPS 10 32 8 8 763 20 14201911 Screw PFHMSUC 6 32 X 3 16 4 9 784 12 14200011 Nut Hex KEPDS 6 32 4 Table 9 20 Toshiba Panel Junction Box Toshiba Panel Junction Box 112 5528G1 9 41 VS 200 Wallstand Installation Operation amp Service Manual 9 23 VS200 Wallstand Accessories 9 42 Part Number Description Qty 103101L18 10 1 103 Line Grid Replaces 8 1 103 Line 1 Grid 103121L18 12 1 103 Line Grid Replaces 8 1 103 Line 1 Grid 500 0008P2 ION Chamber ICX 159 1 110 5022G1 Patient Hand Grips Overhead Lateral 1 B1051 Touch Up Paint Bottle Medical White 1 8000 VS200NM VS 200 Wallstand Installation Operation amp Maintenance Manual 8000 VS200 FMK Floor Mount Kit Installation Instructions 8000 VS200 ATK Auto Tracking Kit Installation Instructions Tabl
50. SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 INTERFACE CABLE 473780700 CONTROL CONSOLE J8 GENERATOR INTERFACE 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT H V CABLE K 3375 60 HV CABLE K 3375 60 10 AWG X RAY TUBE GROUND CABLE 126 520261 65 FT 65FT 5 CND 16 AWG ROTOR CABLE 126 5228G1 40 C 22 GA SH 70 08166 65FT FOR AUTO COLIM 2 CND 22GA SID MONITOR CABLE SUPPLIED W COL En MONITOR WALL STAND RED gt GRN YEL RED BLK GRN P WHT RED TB LONG BLK 7 SOURCE T6 GRN WHT S CROSS r3 T2 Irt lt ION CHAMBER 9 CND 18 AWG CABLE SUPPLIED WITH FMTS 3 CND 16 AWG POWER CORD SUPPLIED WITH FMTS JUMPER LINEAR IV OVER TABLE 3 COLLMATOR w E RER COLLIMATOR 5 2 KE HORIZONTAL ta WALL TABLE HEAD 86 SID CS POWER BUCKY SION Ninna MRI aye 19 9 aas 3 ss SCH BAP Sizo 222 A E a REDJ BLK WHT GRNI BLK RED 2 CND COLLIM EXP HOLD CABLE 73 06525 40FT SUPPLY WITH COLLIMATOR BLK ELEVATING TABLE EV 650 Z GG vua suc 3 lea GI PROGENY suck OPTIONAL COLLIM DIFF TUBECRANE SID POT DIF SID POT 122 507661 122 504261 TB102
51. SUPPLIED W COL ROOM INTERFACE PCB OTC 3 CONT SID PCB zig 124 5087 ES ss TAL POS IN TUBE POS IN EG or Pos our SESE ada DS epe e 3 CND 18 AWG POWER CORD 052449 69FT EXP HLDZ 2 EXP_HLD1 DECH ROOM I F PCB 733184 JBI WBKY_INTERLOCK WBKY INTERLOCK 3 E24vU J10 2 Ri TO CONTROL BOX E em MONITOR post oi BK INTERFACE TABLE ROTOR GENERATOR CONNECT TO CONNECT TO CABLE TOSHIBA TUBE VARIAN TUBE BLK COM TS1 1 WHT LEAD RED MAIN TS1 2 BLK LEAD PROGRAM GENERATOR TO ACTIVATE 1AUX INPUT TB1 4 5 182 AUX INTERLOCK BUCKY SEL Bur SEL LOCK CTRL PCB 5284 135 08 DE SID CABLE 5187 15 03 9 T DIE SID INTERFACE CABLE 125 522451 8 ROOM INTERFACE OLLIM INT PCB JUMPERS B i poe J N SE ORG SHIFT TS1 3 RED LEAD vide YEL Jl Ts1 5 QC TERM een e ia 2 UC SEL BLU THERMAL 151 6 QC TERM BLU GE s ron GENERATOR 184 BRN GROUND GND GND a i INTERFACE PCB AROOM LIGHT GND JUMPERS POS 1 ROOM LIGHT SHIELD Fi 5A 250v AM 24 VAC ROOM DR INT GND STUD T n E HESS 2 GRN YEL PAS GND GND J9 OTC 3 OVE
52. Service Manual 9 8 Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 1 of 2 ALS Section A A Figure 9 5 Vertical Carriage amp Frame Assembly Sheet 1 of 2 9 12 Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 1 of 2 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 2 5400004 Bearing 6 3 6800230 Z Carriage bearing Wheel 6 15 222 5017P1 Carriage Back Plate 1 17 236 5010P1 Block Bearing Mounting 4 20 236 5015P1 Block Lever Mounting 2 23 236 5018P1 Arm Cam Lever 2 24 240 5007P1 Bushing Bearing Spacer 4 25 250 5006P1 Cam Vertical Lock RH 1 26 250 5006P2 Cam Vertical Lock LH 1 27 254 5001P1 Stud Bearing Mounting 6 29 301 5001P1 Carriage Side LH Machined 1 30 301 5002P1 Carriage Side RH Machined 1 38 731 10 00600000 Retaining Ring Ext 6mm Dia 6 41 757 41 25203810 Screw SHSSCP 1 4 20 X 3 8 6 43 758 40 31205010 Screw Shoulder 5 16 18 X 1 2 2 45 762 20 19107511 Screw PFHMS 10 32 X 3 4 10 47 784 20 31200011 Nut Hex Jam 5 16 18 2 Table 9 6 Vertical Carriage amp Frame Assembly Sheet 1 of 2 Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 1 of 2 9 13 VS 200 Wallstand Installation Operation amp Service Manual 9 9 Ver
53. TERMINALS WITH 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE TABLE TO COMPLETE CONNECTION D CONTROL RED BLK RN WHT DIE VS 200 1 3 5 Bi B2 B4 B8 BE RED BLK 77 SOURCE T6 GRN esoe rs T2 1 lt MEDICAI WALL STAND ION CHAMBER INDICO OTC 3 VS 200 LIN IV CONSOLE J8 GENERATOR INTERFACE 054 5077S SHT 25 REV 0 11 07 07
54. VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 1 112 5500G1 Varian Panel Cabinet Assembly 1 2 100012P7 Screw Trim 6 32 X 1 2 8 3 210 5013P1 Middle Cover Medical White 1 4 202 5003P1 Bracket Cover Mounting 4 5 210 5015P1 Bottom Cover Medical White 1 6 214 5012P1 Top Cover Medical White 1 7 232 5001P2 Spacer Top Cover 2 8 408 5099P2 Label Del Med Logo Blue 1 9 306 5014P2 Front Panel Varian W Certification 1 Label 10 642 0018P10 Standoff M F 6 32 X 9 16 Brass 2 11 751 02 19102511 Screw HHMS 10 32 X 1 4 SEMS 4 12 757 41 19103810 Screw SHSSCP 10 32 X 3 8 2 13 760 22 19103111 Screw PPNHMS SEMS 10 32 X 5 4 16 14 203 5220P1 Cover Handle Side 1 15 210 5090P1 Trim Bar 1 16 769 20 14201911 Screw PFHMSUC 6 32 X 3 16 6 Table 9 16 Varian Cabinet Loose Parts Kit Varian Cabinet Loose Parts Kit 112 5504 9 33 VS 200 Wallstand Installation Operation amp Service Manual 9 19 Cooling Fan Assembly 112 5505 BLACK fh Figure 9 16 Cooling Fan Assembly Fig ref Part number Description Qty 1 203 5223P1 Cover Fan 1 652 5012 Fan Cooling 24VDC 3 273 5001P1 Bushing 380D 194 ID 25Lg Nylon 4 786 2014000011 Washer Lock Int 6 4 5 760 20 14215011 Screw PPNHMS 6 32 X 1 1 2 4
55. XU JEE Si BLU Dee TS1 6 QC TERM ri TRN EN r Sa ni T mm JUMPERS POS ROOM LIGHT d 5 ROOM DR NT GND STUD LOCK CTRL PCB 5284 135 08 GENERATOR CONNECT TO CONNECT TO CABLE TOSHIBA TUBE VARIAN TUBE BLK COM TS1 1 WHT LEAD RED MAIN TS1 2 BLK LEAD DIF SID CABLE 518713503 iz a e DE SD INTERFACE CABLE 126 522461 TB1 SHIELD bun GND GND F1 5A 250V 24 VAC 24VL ui OTC 3 OVERHEAD TUBECRANE VS 200 BIZI Ino 110VAC 1 2 82 2 110VAC RI gt SIE 126 5206G1 SOFT x CR Hs A K3 S B8 L 1 110vAC H GRN YEL B6 G 24VDC 5 4 4 J 24vDC 2 24VDC 24VDC AEC PCB 737992 CONTROL PCB OVRET 2 OVRET il ove RED BLK GRN P WHT TB LONG T7 SOURCE T6 WHT WHT ITS cross T5 TZ T1 lt 3 CND 18 AWG POWER CORD 052449 60FT 2 C 22 GA CABLE JUMPER LINEAR IV OVER TABLE 8 COLLMATOR o COLLIMATOR COLLIMATOR A 5 E HORIZONTAL EG HEAD 58 sip POWER XO SEESEE BE EP Sze MEZ ay 356 xs 2 CND COLLIM EXP HOLD CABLE 73 06525 40FT SUPPLY WITH COLLIMATO
56. as well as in tables in X ray rooms it is necessary to plan for sufficient cable slack to allow the operator to move the receptor from wallstand to table and make wallstand vertical adjustments The cable should be unobstructed have no kinking and have sufficient cable length to accomplish efficient use of the movable receptor in the wallstand When all parts are assembled on the wallstand the entire wallstand and CXDI 50 receptor housing may be raised to the vertical mounting position to allow alignment and balancing AN Caution Lifting the combined assembled unit requires two people When the wallstand is installed aligned and balanced proceed with Canon CXDI 50 room installation as instructed in the Canon CXDI 50 Installation manual Canon 50G Image Receptor Wallstand Installation Addendum 2C 1 VS 200 Wallstand Installation Operation amp Service Manual Wallstand Receptor Balancing The VS 200 wallstand Canon configuration is shipped with ten steel plate weights installed in a pocket on the carriage When the grid and CXDI 50 digital receptor and its housing is fully installed adjustments may be needed in the number of weights to achieve smooth movements 1 Snugly install a cable tie on release brake handle to hold it in the released position to allow easy movement 2 Remove and retain four screws 1 in Figure Addendum 2C 1 holding the Vertical Carriage and Frame top cover 2 to access the weight holding pocket 3
57. be turned on 2 1 2 X ray Room Pre planning Consult with the client and or client physical plant superintendant prior to beginning installation to verify that the site has sufficient power and utility Local Area Network infrastructure Use shipping order and any statement of work job orders or any client room drawings special written or unwritten requirements before beginning installation to determine site specific requirements and client requests or room workflow considerations that will need to be accommodated in the installation Pre installation Pre planning 2 1 VS 200 Wallstand Installation Operation amp Service Manual 2 2 2 1 3 Planning Orienting Release Brake Handle Grid Door and Imaging Cable X ray room operators should be able to use the wallstand release brake handle and grid receptor door from the same side and there should always be sufficient space for the grid door removable digital imaging receptor to be easily removed during normal room operation The left right orientation of all the above should be appropriate for room workflow consistent with the following planning considerations Plan direction of power and signal cable so that during normal workflow movements persons or equipment in the room do not obstruct impinge kink or crush cable Avoid possible cable interference with wallstand movements Provide sufficient cable slack to allow wallstand vertical movement 2 1 4 Digita
58. from the x ray tube side of the ion chamber Field selects 3 2 and 1 select left A center B and right C respectively as viewed from the x ray tube side of the ion chamber Time integrated signal ramping from OVDC to a maximum of at least 8096 of the supply voltage 9 6VDC for 12VDC supply The slope of this signal is directly proportional to the amount of x ray flux received Time integrated signal ramping from OVDC to a maximum of at least 80 of the supply voltage 9 6VDC for 12VDC supply The slope of this signal is directly proportional to the amount of x ray flux received Sina Switch Comments Power Supply Isolation Defeated SW1 1 ON Connects external 61154A Pin 9 to pre amp chassis and ion chamber frame Default Setting Power Supply SW1 1 OFF Separates external 61154A Pin 9 from pre amp Isolation Enabled chassis and ion chamber frame to prevent ground loop 61154 Caibration Instructions P N 69329 REV 2005 Advanced Instrument Development Inc 17 March 2005 Page 5 Advanced Instrument Development Inc 1011 N 25th Ave Melrose Park IL 60160 U S A Phone 708 343 7777 www aidxray com Fax 708 343 7795 Specific Configurations Unless specified otherwise ICX ion chambers are delivered with an AID compatible jumper configuration AID compatible means that the input and output signals will interface with Advanced Instrument Development Inc s Expos AID
59. power sources outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 5 4 Converting Left Right Right Left Configurations VS 200 Wallstand Installation Operation amp Service Manual 1 Manually pull cassette tray out as far as it will go 2 While firmly pressing on limit button 1 in Figure 5 2 pull the cassette tray completely out of the bucky Figure 5 2 Cassette Tray Removal 3 Remove the wallstand s wall and floor mounting screws 4 Carefully lay wallstand down on a soft rug or other soft surface with the receptor plane facing up 5 Unscrew two top cover screws 1 in Figure 5 3 and remove top cover 2 Figure 5 3 Top Cover Screws Converting Left Right Right Left Configurations 5 5 VS 200 Wallstand Installation Operation amp Service Manual 6 Unscrew four bottom cover screws 1 in Figure 5 4 and remove bottom cover 2 Figure 5 4 Bottom Cover Screws 7 Slide front panel 1 in Figure 5 5 straight up and off the wallstand 8 Unscrew two side cover screws 2 and remove side cover 3 Figure 5 5 Side Panel amp Front Panel 5 6 Converting Left Right Right Left Configurations VS 200 Wallstand Installation Operation amp Service Manual Only do steps 9 amp 10 if your wallstand has an optional PBL cassette size sensing kit 9 Cutcable ties 1 in Figure 5 6 10 Disconnect wires 2 from terminal 3 F
60. step 5 Chapter 2 page 2 5 Addendum E 24 Toshiba FDX4343R Image Receptor Installation Operation 3 1 Safety Precautions AN Warning No foreign objects which can attenuate or scatter the X ray beam are allowed between x ray tube and wallstand during exposure Failure to follow this may result in serious injury A Warning This wallstand is intended to be used as part of a system for the intended generation of X rays for medical diagnosis X rays generate a potential risk for both patients and operators For this reason the application of X rays for a given medical purpose must aim at the minimization of radiation exposure to any persons Those persons responsible for the application must have the specific knowledge according to legal requirements and regulations and must establish safe exposure procedures for this kind of system Those persons responsible for the planning and installation of this equipment must observe the national regulations Note If the wallstand is equipped with one of the optional digital receptors refer to the corresponding documentation for controls and operation information on that part of the system Safety Precautions 3 1 VS 200 Wallstand Installation Operation amp Service Manual 3 2 Specifications Specifications Compatibility The VS 200 wallstand is compatible with a wide variety of gen erators and tubestands It is intended to be used in a stationary diagnostic x ray configu
61. the cassette tray handle to pull the film cassette tray out of its holder For safety reasons the cassette tray will not come completely out The cassette tray can be completely removed according to Section Completely Removing the Cassette Tray on page 3 9 3 3 2 Release Brake Handle digital receptors and regular bucky Squeeze the release brake handle to release the brake This will allow you to move the cassette tray holder to the desired position Controls 3 3 VS 200 Wallstand Installation Operation amp Service Manual 3 4 Operating Instructions regular bucky Operate the Wallstand as follows 1 Manually pull cassette tray 1 in Figure 3 2 out as far as it will go Figure 3 2 Cassette Tray 2 Liftclamp 1 in Figure 3 3 up 3 If necessary move bracket 2 to the position that matches the size of your cassette Te DEL MEDICAL Figure 3 3 Clamp amp Bracket 3 4 Operating Instructions regular bucky VS 200 Wallstand Installation Operation amp Service Manual 4 Insert cassette 1 in Figure 3 4 into tray 5 Slide clamp 2 up to cassette and close clamp Figure 3 4 Cassette amp Clamp 6 Push cassette tray all the way in Figure 3 5 Cassette Tray In Operating Instructions regular bucky 3 5 VS 200 Wallstand Installation Operation amp Service Manual 7 Squeeze and hold release brake handle 1 in Figure 3 6 8 Move cassette holder to desired position and let go o
62. then securely tighten mounting bolts 2 10 Installation VS 200 Wallstand Installation Operation amp Service Manual 21 Remove shipping bolt 1 in Figure 2 12 Figure 2 12 Shipping Bolt Installation 2 11 VS 200 Wallstand Installation Operation amp Service Manual 22 Unscrew bracket screw 1 in Figure 2 13 and remove washer 2 and shipping bracket 3 Figure 2 13 Vertical carriage locking bolt bracket 23 If your wallstand does not have any options no bucky automatic exposure control casette size sensing or overhead lateral handgrip then you are done If your wallstand does have the mentioned options Digital Receptors Used on Wallstand refer to Table 2 1 for guidance Option Digital Receptor Refer to Section Addendum Bucky Bucky Installation Instructions G1 G3 on page 2 13 Automatic Exposure Control Automatic Exposure Control Installation Instructions on page 2 17 Automatic Cassette Size Sensing Automatic Cassette Size Sensing Installa tion Instructions on page 2 20 CMT SmartRAD See Addendum A Canon CXDI 40EG See Addendum B Canon CXDI 50G See Addendum C Varian Paxscan 4343R See Addendum D Toshiba FDX 4343R See Addendum E Table 2 2 Options Digital Receptors Used on Wallstand 1 The addendums are to be found at the end of this chapter 2 12 Installation VS 200 Wallstand Installation Operation amp Service Manual 2 3 Bucky I
63. 077S SHT 15 REVISION 2 ECN 8003 10 30 07 HAND SW EXPOSURE INDICO 100 SERIES SHIFT MAIN COM GND THERMSW THERMSW TUBE 1 ROOM INTERFACE PCB ROOM F PCB 733184 d NBKY INTERLOCK WBKY INTERLOCK PROGRAM GENERATOR TO ACTIVATE 1 AUX INPUT TB1 4 5 TB2 AUX INTERLOCK BUCKYI SEL T BUCKYI SEL E 8 ROOM INTERFACE 7COLLIM INT PCB JUMPERS POSITION SIBUCKY CONT JW3 4 6 4 BUCKY_CONT_RET 3j JWA 4 6 2 IBUCKY2 SEL GENERATOR TB4 INTERFACE PCB ROOM LIGHT JUMPERS POS 1 ROOM LIGHT 9 MI 3 8 W10 3 4 1 2 ROOM DR INT TB3 BKY START 189 110VAC 110VAC 110VAC 110VAC 1109 H OVRET Neel x E CR 4 24VDC 2 3 24VDC 24VDC anc WHT WHT 2 OVRET il ove AEC PCB 737992 JUMPER OVER TABLE COLLIMATOR LOGIC LINEAR Il COLLIMATOR 3 CND 18 AWG POWER CORD 052449 60FT H V CABLE K 3375 60 OTC 3 HOUSE HN CABLE K 3375 60 10 AWG X RAY TUBE GROUND CABLE 126 520261 5 CND 16 AWG ROTOR CABLE 126 5228G 65 FT 15 CND 22 AWG HORIZ SID CABLE 5187 134 10 60FT 40 C 22 GA SH 70 08166 65FT FOR AUTO COLIM
64. 1 VS 200 Wallstand Installation Operation amp Service Manual 3 Unscrew mounting screws 1 in Figure 6 30 4 Disconnect connector 2 5 Reverse steps to reassemble Figure 6 30 Fan Removal 6 22 Replacing Cooling Fan Troubleshooting 7 1 Introduction This chapter is divided into two sections The first section is a group of troubleshooting charts that will guide you through most of the problems that may occur with the wallstand The second section is made up of an overall schematic of the wallstand and a group of illustrations and photos that show the actual parts depicted on the schematic and their location on the wallstand Introduction 7 1 VS 200 Wallstand Installation Operation amp Service Manual 7 2 Troubleshooting Index amp Charts Use the following troubleshooting index and troubleshooting charts as an aid in solving your wallstand s malfunction For troubleshooting on optional digital receptor refer to troubleshooting section in the digital receptor documentation Problem Refer to Page Brake does not hold well or at all 7 2 Up and down movement of cassette 7 2 holder is difficult Cannot fully remove cassette tray 7 2 Dark bands on film 7 3 Bucky does not work 7 4 Cassette size sensing does not work 7 4 Exposure very light very dark or 7 5 intermittently poor Problem Possible Cause Remedy Brake does not hold well or at all Brake
65. 1 4 4 18 760 20 16203811 Screw PPNHMS 8 32 X 3 8 3 Table 9 18 Toshiba Panel Cabinet Assembly Toshiba Panel Cabinet Assembly 112 5526G1 9 37 VS 200 Wallstand Installation Operation amp Service Manual 9 21 Toshiba Panel Cabinet Loose Parts Kit 112 5527G1 Figure 9 19 Toshiba Panel Loose Parts Kit 112 5527G1 9 38 Toshiba Panel Cabinet Loose Parts Kit 112 5527G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 1 112 5526G1 Assembly Cabinet Toshiba 1 FDX4343R 2 1000112P7 Screw Trim 6 32 X 1 2 8 3 210 5013P1 Middle Cover Medical White 1 4 203 5229 Bracket Cover Mounting 4 5 306 5015P2 Front Panel Varian w certification 1 Label 6 214 5012P1 Top Cover Medical White 1 7 232 5004 Spacer Cover 2 8 210 5015P1 Bottom Cover Medical White 1 9 642 0018P10 Standoff M F 6 32 X 9 16 Brass 2 10 751 02 19102511 Screw HHMS 10 32 X 1 4 SEMS 4 11 757 41 1910 3810 Screw SHSSCP 10 32 X 3 8 2 12 760 22 19103111 Screw PPNHMS SEMS 10 32 X 5 4 16 13 203 5220P1 Cover Handle Side 1 14 210 5090P1 Trim Bar 1 15 736 20 14201911 Screw PFHMSUC 6 32 X 3 16 Table 9 19 Toshiba Panel Loose Parts Kit Toshiba Panel Cabinet Loose Parts Kit 112 5527G1 9 39 VS 200 Wallstand Installation Operation amp Service Manual 9 22 Toshiba Panel Junction Box 112 5528G1 TOSO
66. 11 Screw HHMS 1 4 20 X 3 4 1 26 751 0031207511 Screw HHMS 5 16 18 X 3 4 5 27 751 00 31213811 Screw HHMS 5 16 18 X 1 2 28 756 40 31210010 Screw FSHMS 5 16 18 X 1 3 29 784 12 31200011 Nut Hex KEPS 5 16 18 2 Table 9 4 Column Assembly Column Assembly 112 5018G1 9 9 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 30 784 50 25200016 Nut Acorn HI 1 4 20 4 32 786 50 25000011 Washer Split Lock Standard 1 4 1 33 46 220183P1 Bumper 3M SJ 5523 Black 2 34 46 220181P8 Washer Split Lock 5 16 5 Table 9 4 Column Assembly 9 10 Column Assembly 112 5018G1 VS 200 Wallstand Installation Operation amp Service Manual 9 7 Counterweight Assembly 112 5016G1 5 12 5 Long 5 25 Long Figure 9 4 Counterweight Assembly Fig ref Part number Description Qty 2 230 5004P1 Spacer Spring Mounting 1 3 236 5011P1 Block Counterweight Anchor 1 4 403 5003P1 Counterweight Cable 1 5 412 0007P2 Felt Strip 12 Thick 06 6 436 5004P1 Counter Weight 94 5 1 7 67 292 Bumper Spring 1 8 757 41 38212510 Screw SHSSCP 3 8 16 X1 2 9 758 40 25210010 Screw Shoulder 1 4 X 1 00 1 10 784 10 19200011 Nut Hex 10 24 1 11 785 13 31000011 Washer Flat 5 16 Wide 1 Table 9 5 Counterweight Cable Assembly Counterweight Assembly 112 5016G1 9 11 VS 200 Wallstand Installation Operation amp
67. 200 Wallstand Installation Operation amp Service Manual 47 Reverse steps to reassemble See Figure 5 24 amp Figure 5 25 for wiring information for PBL and bucky Be sure to recheck alignment according to Chapter 2 when setting wallstand back up 48 Adjust brake according to Section Adjusting Brake Cams on page 5 3 www Not GRN WHT RED BLK BRN Used ORG Figure 5 24 Bucky Wiring Diagram EX A TIDIGRN Oe 3 Figure 5 25 PBL Wiring Diagram Converting Left Right Right Left Configurations 5 17 VS 200 Wallstand Installation Operation amp Service Manual 5 18 Converting Left Right Right Left Configurations Component Replacement 6 1 Introduction This chapter provides instructions for replacing components on the wallstand Introduction 6 1 VS 200 Wallstand Installation Operation amp Service Manual 6 2 Replacing Fuses This procedure describes how to replace bucky fuses For digital receptor fuses refer to the digital receptor documentation Tools Required medium phillips head screwdriver small flat tip screwdriver Fuses Progeny Bucky F1 1A 250V MDL F2 3 4A 250V MDL e F3 1A 250V MDL Fuses Potter Villa Bucky F1 0 3A 250V T e F2 0 2A 250V T e F3 1 6A 250V T AN Warning Turn off all electrical power to wallstand and all its peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure
68. 263 03 Ji NOTE DEPENDING ON THE ION CHAMBER MAKE JUMPER CONFIGURATION AND INTERFACE AS SPECIFIED UN ELEVATING TABLE UN ln EV 650 ERI SCHEMATIC IM 014 OR IM 015 OR sui SREBSS VILA BUCKY IM 018 OR IM 019 IM O81 IN co ko nj ein SEDECAL MANUAL SPERARE mes S SSES PRUGENY BUCKY Sillem Je z zo a z il D LIT 04 m Usa cpm P106 J106 i J204 seh J202 lt PE lt ION CHAMBER 24D 40 VSIDR 25D 40 VSID 22D 40 HSID 21D SIDCOM 20D 72 HSID DRIVER LE DI TB101B G BRN RED BLU GRN YEL TD INCOMING POWER DISCONNECT DR SEDECAL GENERATOR 3 CND 18 AWG POWER CABLE 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 OPTIONAL AEC CABLE FACTORY SUPPLIED JS COMMUNICATION CABLE FACTORY SUPPLIED ATP BDARD DEL MEDICAI SEDECAL EV650 K860 VS200 MC150 034 5076S SHT 8 REVISION 1 ECN 8003 10 29 07 HAND SW POWER CABLE FACTORY SUPPLIED EXPOSURE COPTIONAL SEDECAL OPERATOR CONSOLE CPI CMP 200 SERIES H V TANK
69. 3 2 SI We ONE ORG See Le aset pU exe da teet Aaa e v aia sc 3 3 VS 200 Wallstand Installation Operation and Service Manual 3 3 1 Cassette Handle regular bucky 3 3 3 3 2 Brake Handle digital receptors and regular bucky 3 3 3 4 Operating Instructions regular bucky 3 4 3 5 Using Overhead Lateral Handgrip Option 3 7 3 6 Completely Removing the Cassette 3 9 Chapter 4 Periodic Maintenance 4 1 Periodic Maintenance Schedule 4 1 4 2 Cleaning External Surfaces ilari 4 2 Tools Required cielo nie DERE 4 2 4 3 Checking Counterweight Cables 4 3 Tools Required tev sou sae vi paga ER E 4 3 4 4 Checking Brake Performance 0000 4 4 Tools Requited isla nb EE I CERO e es 4 4 4 5 Checking Fasteners for Tightness 4 5 Tools Required i52 reo erae ee 4 5 Chapter 5 Calibration amp Adjustment S Introd uc BOTE e arto edes ene edes vx ca e a oe Pes qa fe 5 1 5 2 Calibrationa s scc oto ae oda ect a cede v Re uia stein d 5 2 5 9 Adusting Brake eg ar p eed 5 3 Tools Requitediec cu os Mo oec neci Gus A wal TOR Pace da 5 3 5 4 Converting Left Right Right Left Configurations 5 4 Tools Requit d pulire 5 4 Chapter 6 Component Replacement 6 1 Intredu eti n a aes ow aca ede A AERA CE OP EROR d 6 1 6 2 Replacing Fus s pases weder
70. 4 12 19100011 Nut KEPS 10 32 13 48 785 11 19000011 Washer Flat 10 Narrow 3 Table 9 7 Vertical Carriage amp Frame Assembly Sheet 2 of 2 Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 2 of 2 9 15 VS 200 Wallstand Installation Operation amp Service Manual 9 16 Fig ref Part number Description Qty 50 423 0007P1 Nut Seld Locking 10 32 1 51 203 5049P1 Cover Plate 1 52 100012P3 Screw Trim 10 32 X 3 8 2 Table 9 7 Vertical Carriage amp Frame Assembly Sheet 2 of 2 Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 2 of 2 VS 200 Wallstand Installation Operation amp Service Manual Page Intentionally Blank Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 2 of 2 9 17 VS 200 Wallstand Installation Operation amp Service Manual 9 10 Grid Cabinet Assembly 112 0597G1 Figure 9 7 Grid Cabinet Assembly 9 18 Grid Cabinet Assembly 112 0597G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 2 114 0344G2 Weldment Grid Cabinet 1 3 202 0186P2 Inside Framework 1 4 112 0594G1 Channel Assembly 2 5 112 0595G2 Mounting Bracket Assembly 1 6 1417 0117 1 Guide Assembly 2 7 203 0258P2 Rear End Cap 1 8 3920 0295 Plastic Bumper 2 9 46 208908P33 Screw SFHMS 8 32 X 3 8 4 10 46 170012P37 Nut Hex KEPS 8 32 X 5 32 6 11 46 170015P16 Screw BHMS 10 32 X
71. 43 7795 Low Active Commands Reset amp Field Selects High Active Commands Reset amp Field Selects Field Configuration A 1 B 2 C 3 Field Configuration A 2 B 1 C 3 Field Configuration A 3 B 1 C 2 Field Configuration A 3 B 2 C 1 Positive Output Negative Output Power Supply Isolation SW1 3 OFF SW1 4 ON SW1 3 ON SW1 4 OFF SW2 1 5 amp 8 ON SW2 2 3 4 6 amp 7 OFF SW2 2 4 amp 8 ON SW2 1 3 5 6 amp 7 OFF SW2 3 4 amp 7 ON SW2 1 2 5 6 amp 8 OFF SW2 3 5 amp 6 ON SW2 1 2 4 7 amp 8 OFF SW3 1 ON SW3 2 OFF SW3 1 OFF SW3 2 ON Pulling the Reset line to ground lt 6VDC beginning at exposure start and lasting for the entire duration of the exposure allows the integrator to operate Pulling the field select lines to ground lt 6VDC will select the field Driving the Reset line high 28VDC beginning at exposure start and lasting for the entire duration of the exposure allows the integrator to operate Driving the field select lines high gt 8VDC will select the field Field selects 1 2 and 3 select left A center B and right C respectively as viewed from the x ray tube side of the ion chamber Field selects 2 1 and 3 select left A center B and right C respectively as viewed from the x ray tube side of the ion chamber Field selects 3 1 and 2 select left A center B and right C respectively as viewed
72. 50 Bucky 1 7 500 5081 MNL Canon 50 Bucky 1 8 642 0018P17 Standoff M F 10 32x7 8 Zink Plt 8 9 760 22 19103111 MNL Screw PPNHMS SEMS 10 32x5 16 6 10 760 20 14203111 MNL Screw PPNHMS 6 32x5 16 6 Table 9 12 Mounting Frame Canon 50 Digital Receptor Mounting Frame Canon 50 Digital Receptor 112 5404G1 9 27 VS 200 Wallstand Installation Operation amp Service Manual 9 15 Varian Panel Cabinet Assembly 112 5504G1 Figure 9 12 Varian Panel Cabinet Assembly 112 5504G1 9 28 Varian Panel Cabinet Assembly 112 5504G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 1 114 5174P1 Weldment Cabinet Varian 1 2 112 5501G1 Varian Cabinet Grid Tray Assembly 1 Refer to Section 9 16 for Break down of Assembly 3 214 5035P1 Channel Tray 2 4 203 5218P1 Cover 1 5 203 5219P1 Bracket Track Support 1 6 210 5089P1 Spacer Receptor 2 7 784 12 16200011 Nut Hex KEPS 8 32 6 8 760 22 16202511 Screw PPNMS SEMS 8 32 X 1 4 6 9 736 20 16202511 Screw UPFHMS 8 32 X 1 4 8 10 112 5503G1 Grid Detection Switch Assembly 1 Refer to Section 9 17 for Break down of Assembly 11 407 5003P39 Bushing Snap 1 Table 9 13 Varian Panel Cabinet Assembly Varian Panel Cabinet Assembly 112 5504G1 9 29 VS 200 Wallstand Installation Operation amp Service Manual 9 16 Varian Cabinet Grid Tray Assembl
73. 50G3 65FT 4 C 22 GA CASSETTE PRESENCE CABLE 07 09102 9 CND SHLD ION CHAMBER CABLE 75035 45 45FT 6 C 18 GA WALL BUCKY CBL_ 126 5089G1_65FT 4 C 22 GA CASSETTE SENSE CABLE 07 09101 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 45FT DEL MEDICAI INTERCONNECT EV650 CPI CMP DCTM LINEAR IV 034 5076S SHT 2 REV 3 ECN8003 10 29 07 H V TANK CATHODE APX 525 DXR 30 X RAY GENERATOR HV CABLE K3375 XX HV CABLE K33 9 XX ROTOR CABLE 60FT ANODE CONNECTOR PCB 650 0115 I I I DOOR INTRIK COLLI INTRIK JI COMMON I I I I I I I TBI XL XS XC DSS TBE PHASE MAIN COMMON THERMAL SW THERM SW COM S CND CABLE 126 6161 JUMPER WALL SELECT WALL FEEDBACK 317VAC CKT COMMON RG D T17VAC_COM amp Sb Is een NAS ej SI 3 Ll ss ala eee a Silb lea ag UEFA CH FE EES A SSN TABLE FEEDBACI za HERRERNES a B888 cea aI WIVAC ciale Fe EENE EI a Eee Sasasa DC CR SES EE Ee E Eee a EIE al SA inte r SIE SD ale of YS SS TI7VAC COM J5029G J5029F J5029E J5029B POWER SUPPLY amp INTERFACE PCB 124 5029 GRN YEL GRN YEL CBI gi Cani SA 240VAC
74. 6 784 43 14200011 Nut Hex Nylock 6 32 4 7 46 170451P6 Connectro Amp 1 480305 0 1 8 511A590P 152 Terminal Amp 61116 4 TIN 2 Table 9 17 Cooling Fan Assembly 9 34 Cooling Fan Assembly 112 5505 VS 200 Wallstand Installation Operation amp Service Manual Page intentionally blank Cooling Fan Assembly 112 5505 9 35 VS 200 Wallstand Installation Operation amp Service Manual 9 20 Toshiba Panel Cabinet Assembly 112 5526G1 SECTION A A Figure 9 17 Toshiba Panel Cabinet Assembly 112 5526G1 Part A 9 36 Toshiba Panel Cabinet Assembly 112 5526G1 VS 200 Wallstand Installation Operation amp Service Manual Figure 9 18 Toshiba Panel Cabinet Assembly 112 5526G1 Part B Fig ref Part number Description Qty 1 114 5182P1 Weldment Cabinet Toshiba 1 FDX4343R 2 112 5501G1 Assy Grid Tray Varian Cab 1 3 112 5503G2 Assy Stop Grid Tray 1 4 203 5228P1 Adapter Plate 2 5 214 5035P1 Channel Tray 1 6 203 5226P1 Cover 1 7 250 5030P1 Spacer 4 8 2035219P1 Brkt Track Support 1 9 201 5177P1 Handle 2 10 407 5003P39 Bushing 2 11 784 12 16200011 Nut Hex KEPS 8 32 13 12 784 12 19100011 Nut Hex KEPS 10 32 4 13 762 20 16208811 Screw PFHMS 8 32 X 7 8 4 14 760 22 16202511 Screw PPNHMS SEMS 8 32 X 1 4 2 15 760 22 16203111 Screw PPNHMS SEMS 8 32 X 312 4 16 705 00 04000800 Screw FSHMS M X 8 16 17 763 20 16202511 Screw UPFHMS 8 32 X
75. 7 Size Sensing Cassette Tray Cassette Size Sensing Circuit PBL Option Figure 8 2 Cassette Size Sensing Circuit Electrical Schematics 8 3 VS 200 Wallstand Installation Operation amp Service Manual 8 2 Configuration Schematic Match Table Generator Tube Stand Collimator Model Wall Stand Referto Draw Current Model Crane Model ing Rev Level Model APX 525 625 K860Floor Ceiling Eureka Linear Il VS200 034 5076S1 3 amp DXR 30 Mounted Tube stand CMP 200 DCTM Tubestand Eureka Linear IV VS200 034 5076S2 3 DFMT Tubestand APX 525 625 DCTM Crane Eureka MC 150 VS200 034 5076S3 3 amp DXR 30 DFTS Tubestand Sedecal K860 Floor Ceiling MC series VS200 034 5076S8 1 Mounted Tube stand CPI CMP FMTS Tubestand Eureka Linear Il VS200 034 5076S9 1 CMP 200 OTC 3 Crane Eureka MC 150 VS200 034 5077S1 4 CMP 200 OTC 3 Crane Eureka Linear Il VS200 034 5077S3 4 CMP 200 OTC 3 Crane Eureka Linear IV VS200 034 5077S4 3 Indico 100 OTC 3 Crane Eureka MC 150 VS200 034 5077S8 4 Indico 100 OTC 3 Crane Eureka Linear IV VS200 034 5077810 4 Indico 100 3D Top CTM Siemens VS200 034 5077S14 3 APX 525 625 OTC 3 Crane Eureka MC 150 VS200 034 5077515 2 amp DXR30 Indico 100 OTC 3 Crane Eureka Linear Il VS 200 034 5077517 3 CMP 200 OTC 3 Crane Eureka Linear Il RT100 034 5077518 VS200 CMP 200 FMTS Tubestand Eureka Linear IV VS200 034 5076819 2 Indico 100 OTC 3 Crane Eu
76. 9mm 12 9 16 319mm c 31 3 4 806mm 31 3 4 806mm d 25 1 8 638mm 25 1 8 638mm e 56 1 4 1429mm 56 1 4 1429mm f see next page 15 1 2 394 mm 73 3 8 1864 mm 15 1 2 394 mm 73 3 8 1864 mm g 25 635 mm 25 635 mm h 12 3 8 314 mm 12 3 8 314 mm i 11 279 mm 11 279 mm j 5 127 mm 5 127 mm 1 6 Dimensions VS 200 Wallstand Installation Operation amp Service Manual 190 mm 71 2 219 mm 8 5 8 125 mm 4656 N 1 83 2108 mm Figure 1 3 Wallstand Dimensions The optional overhead hand grip will increase the lowest position with the same measure as the thickness of the additional counterweights needed to compensate for the extra weight of the hand grip assembly The optional overhead hand grip will increase the required height of the room With the han dle in it s uppermost position the required free height will be 101 2566 mm Dimensions 1 7 VS 200 Wallstand Installation Operation amp Service Manual 1 5 Mounting Dimensions View B ef 8 90 82 7 25 227mm_ 21mm Ae 9 5mm
77. ABLE FOR CONNECTING CABLE ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING TERMINALS WITH 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE TABLE TO COMPLETE CONNECTION DEL MEDICAI CONTROL WALL STAND ION CHAMBER INDICO OTC 3 EV650 VS 200 LIN IV CONSOLE 034 5077S SHT 10 GENERATOR INTERFACE REVISION 4 ECN 8003 10 30 07 INDICO 100 SERIES ANODE CATHODE H V TANK SHIFT MAIN COM THERMSW THERMSW TUBE 1 ROOM INTERFACE PCB ROOM 1 F PCB 733184 m WBKY INTERLOCK WBKY INTERLOCK PROGRAM GENERATOR 1 TO ACTIVATE 1 AUX INPUT TB1 4 5 AUX INTERLOCK TB2 BUCKYi SEL 1BUCKYl SEL ROOM INTERFACE PCB JUMPERS POSITION MI 4 6 M 4 6 ICOLLIM_INT_ BUCKY CONT 9 8 7 6 5 4 3 2 1 IBUCKY2 SEL GRN YEL GRN YEL GENERATOR INTERFACE PCB JUMPERS POS TB4 ROOM DR INT IRC R INT TB3 BKY START CONNECT TO X99 ON D55 PCB e s 110vac 4 110vAC 3 110vAC 110VAC 311096 H OVRET 2 OVRET WHT JL OVRET WT 24VDC GREEN YELLOW WIRE SUPPLIED WITH 3D TOP C
78. ABLE TO COMPLETE CONNECTION A REMOVE 2 1 4 PO TERMINALS FROM CABLE 126 5213G1 AND CRIMP ONE TERMINAL TO THE BLK LEAD OF CABLE 126 5050G3 CRIMP OTHER TERMINAL TO BRN LEAD OF CABLE 126 5089G1 MAKE THE CONNECTION AS SHOWN TO DISABLE THIS OPTION CONNECT BLK LEAD OF CABLE 126 5050G3 DIRECTLY TO J4 6 ON GEN CONNECT BRN LEAD OF CABLE 126 5089G1 DIRECTLY TO J2 6 ON GEN 120 VAC WALL STAND VS 200 1 BIZI B2 2 B3 3 B4 N BB L B6 G gt GRN YEL RED BLK GRN UP WHT RED BLK 17 SOURCE 16 GRN WET 15 gR0SS T3 T2 m lt ION CHAMBER 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 DEI M EDICAI CPI CMP200 OTC 3 RT100 LIN II VS200 034 5077S SHT 18 REVISION 3 ECN 8003 10 30 07 CPI CMP 200 SERIES H V TANK ANODE CATHODE ROOM INTERFACE PCB J7 SHIFT MAIN COM GND THERMSW THERMSW slasa s kn GRN YEL CRN YEL J4 DOOR INT DOOR INT sasssa BKY2 RDY BKY2 RDY BKY2_RET BKY2 GND BKY2 OUT BKY2 STRT NOTE PLEASE SEE PAGE 3C 5 OF CMP 200 MANUAL ABOUT BUCKY RUN ON W O COMMAND 65FT I AEC PCB 737992 6 C 18 GA WALL BUCKY CBL 126 5089C1 CONTROL PCB 9 CND
79. ACE CABLES SUPPLIED WITH 3D TOP CTM WALL STAND VS 200 1 CONNECT TO X86 ON D55 PCB GRN YEL T7 SOURCE T rs cross ik T2 rt lt ION CHAMBER COLLIMATOR ELEVATING TABLE EV 650 PB VILA BUCKY PROGENY BUCKY OPTIONAL COLLIM DIFF TUBECRANE SID POT DIF SID POT 122 5076G1 122 504261 POWER SUPPLY BOX BRN GRN ION CHAMBER x lal sila S TB102 i2 3 1 3 lo Es EE lt ES Ww SEE SEGR PEEB SVEZIA Cea Saga Que dal KM m l Mao amp Neha sj 2 e Sa PER SERES RI BLK GRN YEL BRN BLU X RAY TABLE POSITION CABLE 126 5244G1 6 C 18 GA TABLE BUCKY CBL 126 505063 65FT 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 120 VAC 9 CND SHLD ION CHAMBER CABLE 75035 45 PONER 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 DEL MEDICAI CPI INDICO EV650 3D TOP CTM VS 200 034 5077S SHT 14 REVISION 3 ECN 8003 10 30 07 OTC 3 HOUSE H V TANK CATHODE H V CABLE K 3375 60 DN CABLE K 3375 60
80. B 25D 40 VSID 24D 40 VSIDR 220 40 HSID 20p 72 HsID J203 T7 S DC RET TB LNG EE 120 VAC POWER 120 VAC POWER 14 GREEN YELLOW WIRE 122 5075G1 FROM WALLSTAND 6 C 18 GA WALL BUCKY CBL 126 5089G1 9 CND SHLD ION CHAMBER CABLE 75035 45 GRN YEL 2 C 22 GA CABLE 126 5206G1 60FT GRN YEL BRN 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 120 VAC POWER 9 CND SHLD ION CHAMBER CABLE 75035245 6 C 18 GA WALL BUCKY CBL_126 5089G1 9 CND SHLD ION CHAMBER CABLE 75035 45 NOTES 126 5178G1 45 FT E A REFER TO INTERFACE TABLE FOR CONNECTING CABLE ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING TERMINALS WITH 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE TABLE TO COMPLETE CONNECTION A REMOVE 2 1 4 PO TERMINALS FROM CABLE 126 5213G1 AND CRIMP ONE TERMINAL TO THE BLK LEAD OF TABLE BUCKY CABLE 126 5050G3 CRIMP OTHER TERMINAL TO BRN LEAD OF WALL BUCKY CABLE 126 5089G1 MAKE THE CONNECTION AS SHOWN TO DISABLE THIS OPTION CONNECT BLK LEAD OF TABLE BUCKY CABLE DIRECTLY TO TB5 4 ON GEN CONNECT BRN LEAD OF WALL BUCKY CABLE DIRECTLY TO TB4 4 ON GEN OPTIONAL 120 501761 UNIVERSAL OPERATOR CONSOLE DEL MEDICAI APX625 OTC 3 EV 650 VS 200 MC 150 034 5
81. ELECT LED TO BE MOUNTED ON APOLLO TUBE COVER lt enD 10 BI O VSIDT WHT JW3 4 6 JW8 2 3 SICOLLIM INT BRN CABLE 126 525261 EAN S TPOST TU jBUCKY CONT BLK E O VSID2 ye 4 BUCKY CONT RET RED T ORG BLU RED RED CABLE 126 525361 TOMO 2 BUCKYZ SEL Pasi mate D r 24 ve OT JBUCKY2 SEL RED BLK aK FORNU 24VL o SRVEN GND STUD GENERATOR TB4 LL1 INTERFACE PCB 2 ROOM_LIGHT JUMPERS POS 1 ROOM LIGHT T zm s RED SITHERMAL SW GLAD BIHERMAL Sw 7 BLK S ROOM DR NTF L5 CABLE 126 522661 EE CUT JUMPER JW11 pR NL RED LOCK CTRL PCB AND JW12 2 a BLK a j 8 TB6 HESE OUT d 5 x SPARE QUT D D E S e A e Bi TB9 e z SS E 51 10VAC I KI 4 4 110VAC B vi B 3LLLOVAC zi K3 2 gt 110VAC e K6 1 1 110VAC x E 38 E a A E2VDC BI OVRET a E WALL STAND A 24vDC 4 OVRET EES FOVRET wur du gt VS 200 2 24vDC 2 OVRET o 1 24vDC Al OVRET E Sai 1 1 81 1 S y RED 2 82 2 De 120 VAC H 3 63 3 POWER BLU i AA ds GRN YEL HERE CH 5 RED RED l vu 1 TB LONG Se BEH BLK 7 7SOURCE va A 16 ul a san 4 ERN 570p5ss f uf om WHT WHT ARES AEC PCB a I 737992 a al t TZ J11 d S n S lt d z LINEAR Il OVER TABLE ti 8 ION CHAMBER al OJ M COLLIMATOR w COLLIMATOR COLLIMATOR s 10 x T a oo TABLE Slo w ol E HORIZONTAL SO WALL TABLE BUCKY HEAD ES i 2 SS sD POWER Gs BUCKY BUCKY s l sr epe I SISS STISTS iD d a nli SE TERRI s sls O NI ARI LEPRE E m
82. N CHAMBER TB1018 250 40 VSID 24D 40 VSIDR TB101A 21D SIDCOM 20D 72 HSID 120 VAC POWER 120 VAC POWER BLK 3 C_24GA SID CABLE 126 5222GC1 60FT RI 3 C 24GA SID CABLE 126 5222G1 60FT GRN YEL BRN BLU 2 C 22 GA CABLE 126 5206C1 60FT 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA TABLE BUCKY CBL 126 505063 65FT 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 6 C 18 GA WALL BUCKY CBL 126 5089C1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 120 VAC POWER 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 22 GA CASSETTE SENSE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 NOTES INTERFACE CABLE 473780700 A REFER TO INTERFACE TABLE FOR CONNECTING CABLE ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING TERMINALS WITH 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE TABLE TO COMPLETE CONNECTION A REMOVE 2 1 4 PO TERMINALS FROM CABLE 126 521361 AND CRIMP ONE TERMINAL TO THE BLK LEAD OF CABLE DEL MEDICAI 126 505063 CRIMP OTHER TERMINAL TO BRN LEAD OF CABLE 126 5089G1 MAKE THE CONNECTION AS SHOWN TO DISABLE THIS OPTION CONNECT BLK LEAD
83. NECT EV650 APX DXR DCTM DFMT MC 150 034 5076S SHT 3 EXPOSURE HAND SW REVISION 3 ECN 8003 10 29 07 H V TANK CATHODE SEDECAL GENERATOR SHF410 PSU ANODE 24VAC POWER SUPPLY CABLE SUPPLIED W COLLIMATOR MODULE 4 REFER TH INSTALLATION MANUAL MANUAL FOR CONNECTING ROTOR CABLE DF DUAL TUBE OR FLUOROSCOPY SPOT FILM TS2 CAN BE MARKED AS 4TS2 107S2 DR 11TS2 DEPENDING ON GENERATOR MODEL TSex 1 MAIN 2 SHIFT lt AUX 3 COM 4 ef ITHERMSW THERMSW K860 FLOOR CEILING MOUNTED TUBESTAND 40 HSID 72 HSID LOCK BOARD TB7 Ss WALL STAND PAVDE 24VDC POWER SUPPLY CABLE VS 200 24VDC RET 24VDC je4VDC RET INTERFACE PANEL TS1 DR 3TSi 1 us eeov vac REFER TO I F 001 ON THE SEDECAL MANUAL FOR CONFIGURATION JUMPERS AND ADD ON CIRCUITRIES FOR DIFFERENCE BUCKY TYPE E 0 VAC BUCKY 1 DR BUCKY 1 MOTION BUCKY 1 MOTION RTN SID CABLE 126 XXXXG1 NOT USED FOR MANUAL COLLIMATOR E 4 5 6 TS1 DR 3TS1 8 115 220V_VAC REFER TO I F 002 DN THE SEDECAL MANUAL FOR CONFIGURATION JUMPERS AND ADD DN CIRCUITRIES FOR DIFFERENCE BUCKY TYPE JoJo VAC 11 BUCKY 2 DR 12 BUCKY 2 MOTION 13 BUCKY 2 MOTION RTN ION CHAMBER GRN YEL GRN YEL GROUND STUD COLLIMATOR HEAD AEC BOARD A3
84. OF CABLE 126 505063 DIRECTLY TO J4 6 ON GEN CONNECT BRN CPI CMP200 OTC 3 EV 650 VS200 LIN IV LEAD OF CABLE 126 508961 DIRECTLY TO J2 6 ON GEN 034 5077S SHT 4 REVISION 3 ECN 8003 10 30 07 CONTROL CONSOLE J8 GENERATOR INTERFACE H V CABLE K 3375 60 OTC 3 HOUSE HV CABLE K 3375 60 10 AWG X RAY TUBE GROUND CABLE 126 520261 65 FT INDICO 100 SERIES 65FT 5 CND 16 AWG ROTOR CABLE 126 522861 SHIFT MAIN COM GND THERMSW THERMSW TUBE 1 A CND 18GA COLLIMATOR CABLE 70 08177 65 65FT 2 C 22 GA EXP HOLD CABLE 126 5226C1 60FT ROOM INTERFACE PCB 2 C 22 GA X RAY POS CABLE 126 5206G1 80FT 3_CND_18 AWG POWER CORD 052449 69FT OTC 3 OVERHEAD TUBECRANE ROOM I F PCB 733184 d i NBKY INTERLOCK WBKY INTERLOCK j EXP HLD2 7 2 EXP HLD1 EN CBI 2 5A INTERFACE TABLE ROTOR GENERATOR CONNECT TO CONNECT TO CABLE TOSHIBA TUBE VARIAN TUBE BLK TS1 1 WHT LEAD RED BLK LEAD PROGRAM GENERATOR TO ACTIVATE 1 AUX INPUT TB1 4 5 TB2 AUX INTERLOCK BUCKYI SEL TBUCKYI SEL BRN mc gt CB2 2 5A o GND STUD BLU LOCK CTRL PCB 5284 135 08 gt COM MAIN 9 GND F1 5A 250V ROOM INTE
85. R 15 CND 22 AWG HORIZ SID CABLE 5187 154 10 60FT ELEVATING TABLE EV 650 lal VILA Bucky rak GEI PROGENY BUCKY OPTIONAL SE COLLIM DIFF TUBECRANE SID POT DIF SID POT 122 507661 122 504261 TB102 J202 ION CHAMBER 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT q 6 C 18 GA TABLE BUCKY CBL 126 505063 65FT 25D 40 VSID 24D 40 VSIDR 22D 40 HSID 20D 72 HSID J203 120 VAC POWER 120 VAC POWER RED BLK 3 C_24GA SID CABLE 126 5222C1 60FT GRN YEL 3 C 24GA SID CABLE 126 522261 SOFT GRN YEL BRN BLU 2 C 22 GA CABLE 126 5206G1 60FT 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 6 C 18 GA WALL BUCKY CBL 126 5089C1 65FT 9 CND SHLD ION CHAMBER CABLE 75035 45 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 120 VAC POWER 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 CA WALL BUCKY CBL 126 5089G1 65FT 22 CA CASSETTE SENSE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 INTERFACE CABLE 473780700 JAN REFER TO INTERFACE T
86. RFACE 8 ZCOLW NT TS1 2 PCB JUMPERS SS POSITION SIBUCKY CONT JW3 4 6 S CONT RET ORG SHIFT TS1 3 RED LEAD sf 8574 6 3 THERMAL TS1 5 YEL QC TERM BLU WITCH TS1 6 QC TERM BRN GROUND GND GND SHIELD GND GND 2 1BUCKY2 SEL GRN YEL GENERATOR TB4 INTERFACE PCB ROOM LIGHT GRN YEL JUMPERS POS JW9 3 4 JW10 3 4 ROOM DR INT TB3 BKY START 60FT ei s 110vac 2 110VAC 3 T10VAC 2 T10VAC Joo OVRET RI gt 126 5206G1 GRN YEL E24VDC 4 3 24vDC 24VDC 1 24vDC WHT WHT 2 OVRET il ovi 3 CND 18 AWG POWER CORD 052449 60FT 2 C 22 GA CABLE AEC PCB 737992 COLLIMATOR HEAD ELEVATING TABLE E EV 650 LX vi BUCKY WEEK E S PROGENY BUCKY OPTIONAL S m COLLIM DIFF TUBECRANE SID POT DIF SID POT 122 507661 122 504261 TB102 J202 ION CHAMBER 12 1 3 A NNA fut m CONTROL PCB lt 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 6 C 18 GA TABLE BUCKY CBL 126 505063 65FT
87. RHEAD TUBECRANE SS 183 BKY START 110VAC TTOVAC 110VAC 110VAC 1 rtovac H OVRET Ei 5 n 3 2 GRN YEL 4 24V0C ES 24VDC 1 24vDC WHT 2 OVRET 1 3 CND 18 AWG POWER CORD 052449 60FT JUMPER r AEC PCB 737992 OVER TABLE LINEAR IV ue COLLIMATOR SE COLLIMATOR E HORIZONTAL E TABLE READ Sa power SS WALL sa SD r BUCKY BUCKY GES STO Wun Wy nnn 1 gt PPP 3 EE Ss st PPer Sao A ea SAF Bx FEF a 2_CND_COLLIM EXP HOLD CABLE 73 06525 40FT SUPPLY WITH COLLIMATOR 15 CND 22 AWG HORIZ SID CABLE 5187 134 10 60FT CONTROL PCB 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 120 VAC POWER 120 VAC POWER 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 9 CND SHLD ION CHAMBER CABLE 75035 45 9 CND SHLD ION CHAMBER CABLE 75035 45 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 22 GA CASSETTE SENSE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 NOTES INTERFACE CABLE 73780700 A REFER TO INTERFACE TABLE FOR CONNECTING ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING
88. SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 120 VAC POWER 6 C 18 GA WALL BUCKY CBL_126 5089G1_65FT 22 GA CASSETTE SENSE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 NOTES INTERFACE CABLE 73780700 A REFER TO INTERFACE TABLE FOR CONNECTING CABLE ROTOR CABLE TO EITHER TOSHIBA OR VARIAN X RAY TUBE IF CONNECTING THE ROTOR CABLE TO VARIAN X RAY TUBE FIRST REPLACE THE 6 RING TERMINALS WITH 1 4 PO TERMINALS PROVIDED AND THEN REFER TO INTERFACE TABLE TO COMPLETE CONNECTION ZA REMOVE 2 1 4 PO TERMINALS FROM CABLE 126 521361 AND CRIMP ONE TERMINAL TO THE BLK LEAD OF CABLE DEL MEDICAI E 126 5050G3 CRIMP OTHER TERMINAL TO BRN LEAD OF CABLE 126 5089G1 MAKE THE CONNECTION AS SHOWN CPI CMP200 OTC 3 EV 650 VS200 LIN Il CONSOLE TO DISABLE THIS OPTION CONNECT BLK LEAD OF CABLE 126 505003 DIRECTLY TO J4 6 ON GEN CONNECT CASEY 034 5077S SHT 3 BRN LEAD OF CABLE 126 5089G1 DIRECTLY TO J2 6 ON GEN J8 GENERATOR INTERFACE REVISION 4 ECN 8003 10 30 07 CPI CMP 200 SERIES H V TANK AME H V CABLE K 3375 60 OTC 3 HOUSE DN CABLE K 3375 60 10 AWG X RAY TUBE GROUND CABLE 126 520261 5 CND 16 AWG ROTOR CABLE 126 5228G1 65 FT 15 CND 22 AWG HORIZ SID CABLE 5187 154 10 60FT CATHODE 65FT 40 C 22 GA SH 70 08166
89. T ROOM INTERFACE PCB J7 SHIFT MAIN COM GND THERMSW THERMSW 3 CND 18 AWG POWER CORD 052449 69FT OTC 3 OVERHEAD TUBECRANE HOER ve 2 S WALL TIEXP HLDZ 2 EXP HLD1 GRN YEL 47 TB1 CBI 2 5A 1 22vU 10 2 T 3 TPOS1 BRN INTERFACE TABLE ROTOR GENERATOR CONNECT TO CONNECT TO CABLE TOSHIBA TUBE VARIAN TUBE BLK COM TS1 1 WHT LEAD RED MAIN TS1 2 BLK LEAD ORG SHIFT TS1 3 RED LEAD Ka gt CB2 2 5A Esc gt GND STUD BLU IN LINE CONNECTOR GRN BLK RED BRN LOCK CTRL PCB 5284 135 08 2 GND F1 5A 250V J2 BKY1 RET sasssa al BKY1_GND BKYI OUT YEL THERMAL Trei QC TERM BKY1 STRT BKYT RDY BLU HEEN ts1 6 QC TERM mE BRN GROUND GND GND INT1 INTTR INT2 INT2R SHIELD Sr GND GND J4 DOOR INT DOOR INT ss 60FT BKY2 RDY BKY2 RDY BKY2 RET BKY2 GND BKY2 OUT BKY2 STRT WALL STAND VS 200 BIZI B2 2 B3 3 B4 N BB L B6 G BRN WHT BLU RED gt GRN YEL GRN YEL 126 5206G1 NOTE PLEASE SEE PAGE 3C 5 OF CMP 200 MANUAL ABOUT BUCKY RUN ON W O COMMAND GROUN GRN YEL RED BLK GRN P WET RED
90. TERFACE IN LINE CONNECTOR CONTROL CONSOLE H V CABLE K 3375 60 OTC 3 HOUSE DN CABLE K 3375 60 10 AWG X RAY TUBE GROUND CABLE 126 5202G1 5 CND 16 AWG ROTOR CABLE 126 5228G 65 FT 15 CND 22 AWG HORIZ SID CABLE 5187 154 10 60FT 65FT 40 C 22 CA SH 70 08166 65FT FOR AUTO COLIM 2 C 22 GA CABLE 126 5206G1 60FT 2 C 22 GA SID MONITOR CABLE SUPPLIED W COLLIMATOR SOFT ADAPTER CABLE 126 522361 4 C 22 GA BUCKY INTERLOCK CABLE 126 5213G1 HEES 2 com WALL 3 CND 18 AWG POWER CORD 052449 69FT OTC 3 CONT SID PCB 124 5087 D ESCH TUBE POS IN EE 2 Pos CS REI Sp MONITOR TO CONTROL BOX DIE POS OUT m BLK E E a fT 2 INTERFACE TABLE GENERATOR CONNECT TO CONNECT TO TOSHIBA TUBE VARIAN TUBE BLK COM TS1 1 WHT LEAD LOCK CTRL PCB 5284 135 08 DIF SID CABLE 5187 135 03 BLK BRN i T RED MAIN TS1 2 BLK LEAD ORG SHIFT TS1 3 RED LEAD TB1 Fon THERMAL ary 68725 Eeer YEL swiicH TS1 5 QC TERM UR 8 TONG BLU HAL Trans QC TERM BLU Er 254 s zu BRN GROUND GND GND Bos 3 GND DEEN es 24 vac 9 ew jo D I M w 4 GEZ HES H 2 GRN YEL SHIELD E GND GND J9 3 OTC 3 OVERHEAD TUBECRANE 4 EE
91. TIONAL L D l COLLIM DIFF TUBECRANE F SID POT DIF SID POT al 122 5076G1 122 5042G1 z z Ls lt lt za E o l d s ze DIR 1 j2 3 i lt EE 2 3 uy 5 EE SE pal y Y NY Y i 9 Sala Z Si 3 120 VAC P Rag POWER ea ZI j 2 OJ IE an ps Kai e e S ZI o O o e 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 120 VAC POWER 9 CND SOLD ION CHAMBER CABLE 72032 45 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 22 GA CASSETTE SENSE CABLE 70 06525 40FT SUPPLY WITH COLLIMATOR 9 CND SHLD ION CHAMBER CABLE 75035 45 INTERFACE CABLE 73780700 3 CND 16 AWG POWER CORD SUPPLIED WITH FMTS 120 240 VAC POWER WALL STAND gt GRN YEL RED BLK GRN gt WHT T7 SOURCE T6 rs cross TA RET TS 12 rt lt ION CHAMBER 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 9 CND SHLD ION CHAMBER CABLE 75035 45 DEI M EDICAL CONTROL CPI CMP EV650 FMTS VS 200 LIN II CONSOLE BEI GENERATOR INTERFACE 034 5076S SHT 9 REVISION 1 ECN 8003 10 29 07 OTC 3 HOUSE CPI CMP 200 SERIES H V TANK CATHODE H V CABLE K 3375 60 H V CABLE K 3375 60 ANODE 10 AWG X RAY TUBE
92. TM COLLIMATOR LOCKS PS TBI SEC 10 11 10 12 10 13 10 14 I 24VAC AEC PCB 737992 30VDC PRI CIRCUIT BREAKER 480VAC 1 PH 15A 65FT 1 2 3 CONTROL PCB 6 C 18 GA WALL BUCKY CBL 126 5089G1 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT TUBE SELECTION CABLE SUPPLIED WITH 3D TOP CTM 9 CND SHLD ION CHAMBER CABLE 75035 45 9 END SHLD JON CHAMBER CABLE 75035 45 INTERFACE CABLE 473780700 CONTROL CONSOLE J8 GENERATOR INTERFACE 18 17 16 15 14 13 1 2 400V 1 3 440V 1 4 480V CONNECT TO X58 ON D55 PCB CONNECT RED WIRE LABELED T1 11 T1 12 T1 13 TO T1 11 29V 32V 1 35V 4 MOVE THE YELLOW WIRE TO T1 4 WAS CONNECTED TO T1 2 l 3D TOP CTM l H V CABLE SUPPLIED WITH 3D TOP CTM H V CABLE SUPPLIED WITH 3D TOP CTM GREEN YELLOW WIRE SUPPLIED WITH 3D TOP CTM ROTOR CABLE SUPPLIED WITH 3D TOP CTM THERMAL CABLE SUPPLIED WITH 3D TOP CTM GREEN YELLOW WIRE SUPPLIED WITH 3D TOP CTM REMOVE GREEN AND WHITE WIRES FROM D13 14X6 CONNECTOR TERMINATED BOTH LEADS TO 2 POS CONNECTOR AND CONNECT TO JUMPER X16 BETWEEN POS 2 AND 3 ON THE CONTROL PCB GRN YEL 3D TOP CTM HEAD GND STUD GREEN INTERFACE CABLE SUPPLIED WITH 3D TOP CTM D13 14X6 INTERF
93. Table of e DEL MEDICAL F Safety VS 200 K Vertical Wallstand x Installation Operation amp Service Manual ENT Installation Periodic Maintenance Calibration amp Adjustment Component Replacement Trouble Shooting Electrical Schematics Illustrated Parts List P N 8000 VS200 Revision D August 8 2011 Notes Copyright 2011 Del Medical Inc All rights reserved This document is the property of Del Medical Inc and contains confidential and proprietary information owned by Del Medical Inc Any unauthorized copying use or disclosure of it without the prior written permission of Del Medical Inc is strictly prohibited Attention Consult Accompanying Documents As Applicable Del Medical Systems Group 50B North Gary Avenue Phone 1 847 288 7000 Roselle IL 60172 Fax 1 847 288 7011 USA Toll Free 1 800 800 6006 www delmedical com Table of Contents Safety Information Introduction esile A EO C dee e ear i 1 Statement E s oue o recess e ey Ud v aae dee i 2 Jb E tribe i 3 Safety Conventions Used in this Manual i 4 Warning Statements ccs nere 1 4 Cautionitatements uuu yu asya la Frari i 5 Equipment Safety Guidelines i 6 Identification Labels Lie tata ER Oe EL ew eee i 8 VS 200 Labeli facet ls le Lei i 8 Optical fiber components i 9 How to handle fiber optic components
94. W 034 5076S SHT 1 REVISION 3 ECN 8003 10 29 07 CPI CMP 200 SERIES 40kW 208 230VAC 3 PH H V TANK CATHODE ANODE RDUM INTERFACE PCB SHIFT PHASE COM GND THERMSW THERMSW IN LINE CONNECTOR BLK BRN RED BLK Je BKY1 RET BKY1 GND BKY1 OUT BKY1 STRT BKY1_RDY BKY1 RDY IN INTIR INT INTER 34 DOOR INT DOOR INT BKY2 RDY BKYe RDY BKY2 RET BKYe GND BKY2 OUT IBKY2 STRT GRN YEL GRN YEL AEC PCB 737992 3 FLDI EIS A RESET 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 6 C 18 GA TABLE BUCKY CBL 126 5050G3 65FT CONTROL PCB INTERFACE CABLE 73780700 CONTROL CONSOLE J8 GENERATOR INTERFACEW HV CABLE K3375 XX HV CABLE K3375 XX 4 CND 16 AWG SHLD ROTOR CABLE 052206 60FT CABLE 643 0040 60FT 40 C 22 GA SH FOR AUTO COLIM RED BLK BLU BRN BRN GRN BL RED IEEE d Hasiera ej 28 mz Rial COT ld balul sea ET FARA UI SSR e aa DEW A wi we NE PITT kal SENS lai Ee a ALA fata Ita ma aaa a gt ma SS aaaea aaa lt dai 2 no STS mi lol II eelere ee E sie Lao Loos SENSE ER ANGEAR J50296 J5029F J5029E J5029B POWER SUPPLY amp INTERFACE PCB 124 5029
95. While this wallstand has been designed for safe operation improper operation or carelessness may result in serious injury or damage to equipment The manufacturer or its agents and representatives assume no responsibility for the following 1 2 1 2 3 Injury or danger to any person from x ray exposure Overexposure due to poor technique selection Injury or danger from improper use of the vertically adjustable carriage Problems or hazards resulting from failure to maintain the equipment as specified in the Installation chapter Equipment which has been tampered with or modified Del Medical Inc is not liable for any damage or injury arising from failure to follow the instructions and procedures provided within the manuals or associated informational material or from user failure to use caution when installing operating adjusting or servicing this equipment Del Medical Inc is not liable for damage or injury arising from the use of this product for any other use than that intended by the manufacturer Statement of Liability 1 3 Definitions VS 200 Wallstand Installation Operation amp Service Manual The table below defines the meaning of various symbols used on labels on the equipment This warning symbol indicates a potential hazard to operators service personnel or equipment It indicates a requirement to refer to the accompanying documentation for details 1 i This symbol indicates that there
96. able Connections Addendum D 18 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 38 Very carefully lift receptor by handles and place it on studs on wallstand Secure in place with nuts 1 in Figure Addendum D 27 removed in step 10 F 9 AC TY DEL MEDICAL k Figure Addendum D 27 Receptor Mounting Varian Paxscan 4343R Image Receptor Installation Addendum D 19 VS 200 Wallstand Installation Operation amp Service Manual 39 If optional ion chamber was removed reinstall it as shown below Figure Addendum D 28 Ion Chamber Installation 40 For optional ion chamber secure chamber in place with mounting screws 1 in Figure Addendum D 29 Figure Addendum D 29 Ion Chamber Mounting Screws Addendum D 20 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 41 For optional ion chamber reconnect cable and hardware as shown below Figure Addendum D 30 ION Chamber Screws 42 Foroptional ion chamber reinstall cover 1 in Figure Addendum D 31 with screws 2 Figure Addendum D 31 ION Chamber Cover Screws Varian Paxscan 4343R Image Receptor Installation Addendum D 21 VS 200 Wallstand Installation Operation amp Service Manual 43 Reinstall grid tray 1 in Figure Addendum D 32 Figure Addendum D 32 Grid Installation 44 Reinstall front cover 1 in Figure Addendum D 33
97. allstand Being Serviced before servicing wallstand You could get seriously injured if you do not Use cleaning wipes and non abrasive hospital grade cleaner to clean external surfaces of wallstand 4 2 Cleaning External Surfaces VS 200 Wallstand Installation Operation amp Service Manual 4 3 Checking Counterweight Cables Tools Required cotton balls 1 Movethe cassette tray holder 1 in Figure 4 1 to its lowest position AN Warning If the wallstand is equipped with a bucky AEC PBL or digital receptor make sure that power source to these components is locked out and tagged Wallstand Being Serviced before servicing wallstand You could get seriously injured if you do not 2 Runacotton ballup and down the length of the two counterweight cables 2 3 Ifthe cable is frayed or damaged fibers from the cotton ball with stick to the damaged patt of the cable If you see any presence of fibers on the cable replace the affected cable according to Section Replacing Counterweight Cable on page 6 4 Figure 4 1 Upper and Lower Panel Screws Checking Counterweight Cables 4 3 VS 200 Wallstand Installation Operation amp Service Manual 4 4 Checking Brake Performance Tools Required e None 1 Repeatedly squeeze and release brake handle 1 in Figure 4 2 while moving casette tray holder through full range of motion If brake shows any sign of weakness adjust it according to Section Adjusting Brake C
98. ams on page 5 3 Figure 4 2 Release Brake Handle 4 4 Checking Brake Performance VS 200 Wallstand Installation Operation amp Service Manual 4 5 Checking Fasteners for Tightness Tools Required phillips screw driver set of open end wrenches 1 Check each exposed fastener for tightness and tighten accordingly Checking Fasteners for Tightness 4 5 VS 200 Wallstand Installation Operation amp Service Manual 4 6 Checking Fasteners for Tightness Calibration amp Adjustment 5 1 Introduction This chapter provides maintenance and adjustment procedures for the wallstand Introduction 5 1 VS 200 Wallstand Installation Operation amp Service Manual 5 2 Calibration Calibration not applicable for this product For calibration of the Digital Imaging System refer to the Digital Imaging Receptor documentation 5 2 Calibration VS 200 Wallstand Installation Operation amp Service Manual 5 3 Adjusting Brake Cams If needed the brake cams holding the vertical carriage can be reinforced by adjusting them as described below Tools Required medium phillips head screwdriver Caution Do not loosen the brake screws more than one turn or they may fall out which would require major disassembly of the wallstand to repair 1 Loosenthetwo brake assembly screws 1 in Figure 5 1 one full turn 2 Pushrelease brake handle 2 no more than 1 8 This will tighten the brake cams 3 Retighten scre
99. and handle guard 6 Note If your wallstand was manufactured before 2008 you may need to order a new bracket Contact Del Medical Technical support for more information Converting Left Right Right Left Configurations 5 13 VS 200 Wallstand Installation Operation amp Service Manual 37 Mount lever 2 in new position with spacer 3 amp nut 1 Figure 5 19 Lock Mechanism Assembly Left amp Right Shown Only do steps 36 44 if your wallstand is equipped with an optional PBL cassette size sensing kit 5 14 Converting Left Right Right Left Configurations VS 200 Wallstand Installation Operation amp Service Manual 38 Unscrew four PBL bracket screws 1 and separate bracket 2 from 39 40 41 42 43 bucky wz Figure 5 20 PBL Bracket Screws Disconnect all wires from terminal 1 in Figure 5 21 Unscrew connector screws 2 Pull connector and harness 3 out through hole 4 Feed harness through hole 5 Mount connector in new position with screws 6 Figure 5 21 Repositioning PBL Connector Converting Left Right Right Left Configurations 5 15 VS 200 Wallstand Installation Operation amp Service Manual 44 Rewire terminal as shown in Figure 5 22 Cime BU Figure 5 22 Wiring Diagram 45 Remount bucky on wallstand 46 Mount PBL bracket on right side of bucky as shown below Figure 5 23 PBL Bracket 5 16 Converting Left Right Right Left Configurations VS
100. and the CXDI 40EG X ray Digital Camera System are installed 7 Proceed with alignment of the wallstand and receptor per Installation Instructions step 5 Chapter 2 page 2 5 Canon 40EG Image Receptor Installation Addendum 2B 5 VS 200 Wallstand Installation Operation amp Service Manual Addendum 2B 6 Canon 40EG Image Receptor Installation Addendum Image Receptor Installation Canon 50G Image Receptor Wallstand Installation The ships with the Canon CXDI 50G installed to the wallstand Although no additional installation or adjustments are needed for the digital receptor you need to take the following into consideration when installing the VS200 Canon CXDI 50G configuration When this manual or the Canon manual refer to the bucky both manuals intend to refer to the digital imaging receptor in its housing The Canon 50G manual uses the term digital imaging unit or sensor unit to refer to digital imaging receptor components in the Canon receptor and its housing Our terminology for a digital imaging receptor is digital receptor The Canon CXDI 50G has a movable digital receptor and grid and most X ray rooms need only one receptor since operators move it from wallstand to table The digital receptor main cable power and signal wiring are permanently attached to the receptor The receptor housing holds the receptor on the wallstand vertical carriage and frame assembly Since the movable receptor can be used in the wallstand
101. atex or cotton gloves Take care to touch the pre amp board as little as possible Take extra care to avoid touching the three air mounted field inputs Oils from your fingers on the air mounts or their components can cause performance degradation The 61154A pre amplifier board can be configured to operate with several different AEC systems If specified at the time of purchase the ion chamber will be delivered with the pre amplifier board already configured for a particular application To reconfigure an ion chamber for a different configuration see the section on lon Chamber Inputs and Output and the section on Specific Configurations at the end of this document The procedure assumes that the installation of the Automatic Exposure Control AEC is complete and that the AEC and x ray generator are in proper working condition After making the necessary interconnections between the ion chamber and the AEC power up the system 61154 Caibration Instructions P N 69329 REV 17 March 2005 Page 1 2005 Advanced Instrument Development Inc Advanced Instrument Development Inc 1011 N 25th Ave Melrose Park IL 60160 U S A Phone 708 343 7777 www aidxray com Fax 708 343 7795 This document represents proprietary information originated by Advanced Instrument Development Inc and which shall not be disclosed or utilized in any manner detrimental to the company s business This document describes the calibration of standard V o
102. ation go to the next step Figure Addendum E 8 Clamp Handle Mounting Toshiba FD X4343R Image Receptor Installation Addendum E 5 VS 200 Wallstand Installation Operation amp Service Manual 9 Remove nuts 1 in Figure Addendum E 9 and bracket Remount bracket on opposite side 2 Figure Addendum E 9 Grid Bracket Addendum E 6 Toshiba FDX4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 10 Remove screws 1 in Figure Addendum E 10 and remove cover 2 Figure Addendum E 10 Handle Front Cover Removal 11 Remove screws 1 in Figure Addendum E 11 and remove cover 2 Figure Addendum E 11 Handle Side Cover Removal Toshiba FD X4343R Image Receptor Installation Addendum E 7 VS 200 Wallstand Installation Operation amp Service Manual 12 Remove screws 1 in Figure Addendum E 12 and remove cover 2 Figure Addendum E 12 Side Cover Removal 13 Remove standoffs 1 in Figure Addendum E 13 Figure Addendum E 13 Standoff Removal Addendum E 8 Toshiba FDX4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 14 Remove screws 1 in Figure Addendum E 14 and frame 2 Figure Addendum E 14 Frame Removal Toshiba FD X4343R Image Receptor Installation Addendum E 9 VS 200 Wallstand Installation Operation amp Service Manual 15 Unscrew lever nut 1 in Figure Addendum E 15 and lift lever 2 and spa
103. cer 3 off of mounting stud 16 Unscrew two inside bracket screws 4 and remove bracket 5 handle guard 6 and handle 7 17 Remove pulley assembly 8 and place in new position 18 Remove bumper assembly 9 and place in new position 19 Remove handle guide 10 and place in new position 20 Slide handle 7 into bracket 5 21 Install bracket 5 and secure in place with screws 4 and handle guard 6 22 Mount lever 2 in new position with spacer 3 amp nut 1 5 2106 7 Figure Addendum E 15 Lock Mechanism Assembly Left amp Right Shown Addendum E 10 Toshiba FD X4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 23 Reinstall frame 1 in Figure Addendum E 16 with mounting screws 2 Figure Addendum E 16 Frame Installation Toshiba FD X4343R Image Receptor Installation Addendum E 11 VS 200 Wallstand Installation Operation amp Service Manual 24 Install standoffs 1 in Figure Addendum E 17 Figure Addendum E 17 Standoff Installation 25 Reinstall covers 1 in Figure Addendum E 18 Figure Addendum E 18 Side Cover Installation Addendum E 12 Toshiba FD X4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 26 Install cover 1 in Figure Addendum E 19 Figure Addendum E 19 Handle Side Cover Installation 27 Install covers 1 in Figure Addendum E 20 and secure with scre
104. d ion chamber e g for chest or table use Also valid for 61154C 61154G 61154J 61154L and 61154N Pre amp Assembly Description Difference from 61154A 61154A Calculated Gain Range 1 0 to 21 0 None a R24 1500 ohm 61154C Calculated Gain Range 1 47 to 34 8 R31 2200 ohm R4 50K ohm B R1 R2 R3 R4 50K ohm 61154G Calculated Gain Range 1 22 to 29 0 R24 1800 ohm R31 2200 ohm R24 1500 ohm 61154J Calculated Gain Range 1 47 to 34 8 R31 2200 ohm R4 50K ohm Side Turn Pots e R24 1800 ohm 61154L de Gain Range 0 83 to R31 1500 ohm Side Turn Pots R31 2200 ohm 61154N Calculated Gain Range 2 2 to 52 2 R4 50K ohm WARNING e Donotattempt to service the equipment unless this service manual has been consulted and is understood e Failure to heed this warning may result in injury to the service provider operator or patient from electric shock and mechanical or other hazards Note When working with the pre amplifier assembly it is important that electrostatic discharge ESD prevention techniques be observed Before touching the pre amp assembly attach an ESD wrist strap to yourself Be sure to ground yourself and the ion chamber frame to dissipate static charges Note The pre amp assembly is a very delicate and sensitive device It is important to keep it as clean as possible Wash and dry your hands thoroughly before working with it and when possible use unpowdered l
105. d movement Figure Addendum E 33 Counterweights 43 Reinstall top cover 1 in Figure Addendum E 34 Figure Addendum E 34 Top Cover Installation Toshiba FD X4343R Image Receptor Installation Addendum E 21 VS 200 Wallstand Installation Operation amp Service Manual 44 Remove junction box cover 1 in Figure Addendum E 35 Figure Addendum E 35 Junction Box Cover Addendum E 22 Toshiba FDX4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual Note All cables can be routed either through wall conduit port 1 in Figure Addendum E 36 or conduit tubing 2 45 Connect power cable 3 to power supply 4 46 If applicable connect AEC cable from generator to ion chamber cable 5 47 Connect detector cable from control unit to detector cable 6 48 Route comm cable 7 through conduit to control unit 49 8 aE z Zia ee EES Latz Figure Addendum E 36 Junction Box Connections Toshiba FD X4343R Image Receptor Installation Addendum E 23 VS 200 Wallstand Installation Operation amp Service Manual 50 Optional for future use Mount detector handles 1 in Figure Addendum E 37 in junction box as shown below Figure Addendum E 37 Detector Handle Storage 51 Reattach junction box cover 1 in Figure Addendum E 38 Figure Addendum E 38 Junction Box Cover 52 Proceed with alignment of the wallstand and receptor per Installation Instructions
106. dirt and oils on them can damage the fiber and contaminate connectors e Never use the fiber pigtail to pick up or support the weight of the device Keep both the device and the optical connector together in your hand s e The fiber is made of a very pure expensive glass Treat it with the same care that would be used when handling expensive crystal glass Do not allow kinks or knots to develop in the fiber Optical fiber components i 9 VS 200 Wallstand Installation Operation amp Service Manual Carefully work out any tangles patience will save time and money Do not pull on the fiber when kinks or knots are present Pulling will only cause knots kinks and curls to tighten increasing the risk of breakage Always use the correct tools for stripping and cleaving the fiber It will save time and reduce breakage caused by scratches Follow all ESD precautions and approved fiber cleaning procedures Always read and comply with the handling instructions on the shipping container i 10 Optical fiber components Record of Revisions 2 1 Revision History REV Date Reason for Change A 7 17 2006 Original B 6 5 2008 CMT SmartRAD and Canon Digital Receptors added C 7 15 2010 Varian Receptor Installation Instructions Added D 8 8 2011 Toshiba Receptor Installation Instructions Added Table ii 1 Revision History Revision History H 1 VS 200 Wallstand Installation Operation amp Service Manua
107. e 9 21 Wallstand Accessories VS200 Wallstand Accessories VS 200 Wallstand Installation Operation amp Service Manual Notes n 1 VS 200 Wallstand Installation Operation amp Service Manual Notes n 2 VS 200 Wallstand Installation Operation amp Service Manual Notes n 3 VS 200 Wallstand Installation Operation amp Service Manual Notes n 4
108. e the CXDI 40EG manual Universal Type Cable Connection Procedure for information on how to access the receptor housing to install power image signal wiring and mounting positions Remove the Stand Type Cable cover Chapter Four of Canon System Installation Procedure Unit Connections Universal Type and Section 4 4 Universal Type and Connecting the Cables show the exit route of the CXDI 40EG Universal Imaging cable 2 The Connecting the Cables section describes a Sensor cable that comes down the rear panel of the sensor unit to the Connector Clamping Plate and then through the Stand Type cable cover Re route the cable in a direction that will allow unobstructed wallstand digital receptor movement by reversing the orientation of the Sensor cable within the Connector Clamping plate and Stand Type cable cover 3 Connect the Ready Lamp cable and Photo timer cable in the same orientation The Imaging Unit internal wiring exits through the Stand Type Cable cover Orient the Connector Connection base to make wiring exit direction of the Imaging Unit Sensor cable Ready Lamp and Photo timer cable appropriate for the workflow Mount the auxiliary base and connector clamping plate with wiring oriented appropriate for the room workflow 4 Be sure that the Main Sensor cable and the Ready Light insulation are locked to the Imaging Unit Anchoring Plate with the sensor relay cable all of which must be secured with the connec
109. ecure chamber in place with mounting screws 1 in Figure Addendum E 26 Figure Addendum E 26 Ion Chamber Mounting Screws Toshiba FD X4343R Image Receptor Installation Addendum E 17 VS 200 Wallstand Installation Operation amp Service Manual 36 For optional ion chamber mount pre amp 1 in Figure Addendum E 27 with screws 2 Figure Addendum E 27 Pre Amp Mounting 37 Connect cables 1 6 in Figure Addendum E 28 from wallstand to receptor as shown below Figure Addendum E 28 Receptor Cable Connections Addendum E 18 Toshiba FDX4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 38 Install grid tray 1 in Figure Addendum E 29 Figure Addendum E 29 Grid Installation 39 Reinstall lower cover 1 in Figure Addendum E 30 and secure in place with screws 2 Figure Addendum E 30 Lower Cover Screws Toshiba FD X4343R Image Receptor Installation Addendum E 19 VS 200 Wallstand Installation Operation amp Service Manual 40 Reinstall bottom cover 1 in Figure Addendum E 31 with mounting screws 2 7 NN Figure Addendum E 31 Bottom Cover Screws 41 Reinstall front cover 1 in Figure Addendum E 32 Figure Addendum E 32 Front Cover Installation Addendum E 20 Toshiba FD X4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 42 Add counterweights 1 in Figure Addendum E 33 to balance wall stan
110. eration amp Service Manual b Leg h d x D e ES S ENS Cy ge 2 Film or Sates tees el 1 Receptor Plane I I See 9 go i lj ana E J Space required to remove film cassette tray or grid f lt Y Figure 1 2 Film bucky Digital receptor Space Requirements Measure Film bucky CMT Canon 40 Canon 50 a 40 1020 mm 41 1042 mm 46 1 4 1175 mm 38 966 mm b 12 3 16 310 mm 14 366 mm 11 1 2 292 mm 11 5 8 296 mm C 27 1 2 699 mm 24 610 mm 24 3 5 625 mm 26 661 mm d 24 3 8 619 mm 28 712 mm 23 584 mm 23 1 4 591 mm e 52 1321 mm 52 1321 mm 57 3 4 1467 mm 49 1 2 1274 mm f see next page 15 7 8 73 1 2 403 1868 mm 15 1 2 69 3 4 394 1772 mm 16 1 2 74 420 1880 mm 14 71 1 2 356 1816 mm g h 25 1 8 638 mm 12 5 16 313 mm 25 1 8 639 mm 13 9 16 331 mm 21 2 3 550 mm 12 305 mm 24 1 2 622 mm 12 3 8 314 mm 11 2 5 290 mm 11 3 8 289 mm 10 11 16 271 mm 10 13 16 275 mm 5 127 mm 6 1 5 153 mm 4 9 16 116 mm 5 1 5 127 mm Dimensions 1 5 VS 200 Wallstand Installation Operation amp Service Manual Measure Varian Paxscan Toshiba FDX 4343R 4343R a 44 1118mm 44 1118mm b 12 9 16 31
111. eration amp Service Manual 7 3 3 Cassette Size Sensing Circuit o o oz ii dg zo S Ss S 25 8 Ne 1 GRN iN BRN 2 s iss IBLU S 23 3 3 a Linerar Il Linerar IV 53 Collimator Collimator iN ORG SL Control Box Control Box 4 79 TS 2 TS 4 25 S RED WHT WHT RTN 5 20 6 INN EL IYEL GRN GRN V Lt Rt 6 21 8 MHT BLK BLK V Source 7 7 19 9 BLK c RED RED V Up Dn 8 8 22 7 Size Sensing Cassette Tray Cassette Size Sensing Circuit PBL Option Figure 7 4 Cassette Size Sensing Circuit Schematic Troubleshooting 7 9 VS 200 Wallstand Installation Operation amp Service Manual 7 10 Schematic Troubleshooting Diagrams amp Electrical Schematics 8 1 Electrical Schematics This chapter contains the electrical diagrams and schematics for the wallstand Drawing Drawing Description Current Rev Number Sheets Level VS 200 Wallstand Wiring Diagram See Figure 8 1 on page 8 2 Casette Size Sensing Circuit See Figure 8 2 on page 8 3 034 5076 amp Interconnect Diagrams for the VS 200 Wallstand and 5 amp 12 See Table 8 2 034 5077 various tables and tubestands on page 8 4 Progeny Bucky Connection Diagram 120 240 V Models 1 B 10 108000 Progeny Bucky Control Assy Drawing 2 F 61154A AID 3 field Isolated Pre Amp Calculation Gain Range 1 02 1 0 to 21 Top Turn Pots AID Three field lonizatio
112. ew bucky top screws 1 in Figure 5 14 and remove bucky 2 Figure 5 14 Bucky Top Screws 21 Unscrew ground screw 1 in Figure 5 15 and remove ground wire 2 22 Screw ground screw back in 23 Unscrew conduit box screws 3 Figure 5 15 Conduit Box Converting Left Right Right Left Configurations 5 11 VS 200 Wallstand Installation Operation amp Service Manual 24 Cut cable ties 1 in Figure 5 16 25 Remove nuts 2 and P clamps 3 26 Pull wire harness 4 out of wallstand Figure 5 16 Harness Ties amp Clamps Left amp Right Configurations Shown 27 Unscrew cover screws 1 in Figure 5 17 and remove cover 2 28 Reinstall cover where conduit box was removed Figure 5 17 Cover Screws 5 12 Converting Left Right Right Left Configurations 29 30 31 32 33 34 35 36 VS 200 Wallstand Installation Operation amp Service Manual Unscrew bracket screw 1 in Figure 5 18 Figure 5 18 Bracket Screw Left amp Right Configurations Shown Unscrew lever nut 1 in Figure 5 19 and lift lever 2 and spacer 3 off of mounting stud Unscrew two inside bracket screws 4 and remove bracket 5 handle guard 6 and handle 7 Remove pulley assembly 8 and place in new position Remove bumper assembly 9 and place in new position Remove handle guide 10 and place in new position Slide handle 7 into bracket 5 Install bracket 5 and secure in place with screws 4
113. f the release brake handle 9 Make exposure and remove cassette e DEL MEDICAL Figure 3 6 Release Brake Handle 3 6 Operating Instructions regular bucky VS 200 Wallstand Installation Operation amp Service Manual 3 5 Using Overhead Lateral Handgrip Option The overhead lateral handgrip provides patients with extra support Use this option as follows 1 Insertthe handgrip post 1 in Figure 3 8 into the socket 2 on the back of the wallstand There are two sockets available either can be used Figure 3 7 Handgrip Insertion Using Overhead Lateral Handgrip Option 3 7 VS 200 Wallstand Installation Operation amp Service Manual 2 Pull the handle 1 in Figure 3 8 slightly out and then adjust its angle to the desired poistion and release handle Figure 3 8 Overhead Lateral Handgrip Option 3 8 Using Overhead Lateral Handgrip Option VS 200 Wallstand Installation Operation amp Service Manual 3 6 Completely Removing the Cassette Tray To completely remove cassette tray do the following 1 Manually pull cassette tray out as far as it will go AN Caution Cassette tray is heavier than it looks 15 Ibs 7 kg Use care when removing it 2 While firmly pressing the cassette tray release latch 1 in Figure 3 9 pull the cassette tray completely out of the bucky Figure 3 9 Cassette Tray Removal Completely Removing the Cassette Tray 3 9 VS 200 Wallstand Installation Operation amp
114. hase Order number Your preferred method of delivery The part number and quantity of all items required 9 1 1 To Order by Fax Fax your order to Del Medical Systems at 1 800 288 7011 Fax orders can be sent 24 hours a day 7 days a week If you need additional assistance please call Del Medical Systems at 1 800 800 6006 and speak to one our Customer Service Representatives Telephone hours are 8 00 a m to 5 00 p m Monday through Friday Central Standard or Daylight Time Note Refer to the Bucky manual for information on Bucky parts Refer to the digital receptor documentation for information on digital receptor parts Ordering Parts 9 1 VS 200 Wallstand Installation Operation amp Service Manual 9 2 How to Use This Parts List 9 2 1 General Part Numbers This chapter contains all part numbers necessary to order wallstand replacement parts and assemblies This illustrated parts breakdown is presented in disassembled order Detail parts are shown below their respective upper level assemblies whenever possible The parts lists follow the illustration for a particular assembly and represent components of that assembly The number listed in the quantity column is the number of the specific part required to complete the assembly and may not reflect the quantity needed for the entire system The lists are divided into four columns The item index numbers refer to the identification number located on the drawing The
115. his chapter Digital Receptor Refer to Addendum CMT SmartRAD Addendum A CMT Image Receptor Installation Canon CXDI 40EG Addendum B CXDI 40E Image Receptor Installation Canon CXDI 50G Addendum C CXDI 50G Image Receptor Installation Varian Paxscan Addendum D Varian Paxscan 4343R Image Receptor 4343R Installation Table 2 1 Addendums for digital receptors Note If this wallstand is being equipped with the VS200 Auto Tracking Kit proceed with the installation instruction enclosed with the VS200 Auto Tracking Kit before continuing VS 200 Wallstand Installation Operation amp Service Manual 5 Move the wallstand to its final installation location Have a second person hold the tubestand while final alignment steps are being made 6 Point the collimator towards the wallstand and turn the collimator s light on 7 Move the crane or tubestand so that the collimator s cross hairs of light align with the centerline axis of the wallstand and the crane or tubestand is approximately at its in out mid point from the wallstand Then release the positioning buttons to lock the crane in place The collimator light will automatically shut off after 30 seconds turn it back on as required Figure 2 3 Typical Wallstand Alignment Installation 2 5 VS 200 Wallstand Installation Operation amp Service Manual 8 Ifthe pattern is tilted as shown below add shims to the bottom of the wallstand until correct
116. igure 5 6 PBL Bracket Screws Only do steps 11 15 if your wallstand has an optional ION chamber automatic exposure control 11 Unscrew four cover screws 1 in Figure 5 7 and remove ION cover 2 Figure 5 7 ION Chamber Cover Screws Converting Left Right Right Left Configurations 5 7 VS 200 Wallstand Installation Operation amp Service Manual 12 Unscrew cable clamp nuts 1 in Figure 5 8 and remove clamp 2 13 Unscrew two connector screws 3 and unplug connector 4 Figure 5 8 ION Chamber Screws 14 Unscrew ion chamber mounting screws 1 in Figure 5 9 Figure 5 9 Ion Chamber Mounting Screws 5 8 Converting Left Right Right Left Configurations VS 200 Wallstand Installation Operation amp Service Manual 15 Slide ion chamber out as shown below Figure 5 10 Ion Chamber Removal Only do steps 14 18 if your wallstand has an optional bucky 16 Cutcable ties 1 in Figure 5 11 17 Disconnect wires from bucky terminal 2 Figure 5 11 Bucky Terminal Connection Converting Left Right Right Left Configurations 5 9 VS 200 Wallstand Installation Operation amp Service Manual 18 Unscrew bucky right side screw 1 in Figure 5 12 Figure 5 12 Bucky Right Side Screw 19 Unscrew bucky left side screw 1 in Figure 5 13 Figure 5 13 Bucky Left Side Screw 5 10 Converting Left Right Right Left Configurations VS 200 Wallstand Installation Operation amp Service Manual 20 Unscr
117. in Figure 2 24 to system PBL cable 2 Green wire goes to green wire white to white etc The figure shows a terminal block 8 connecting the two cables This terminal block is not provided with the wallstand Figure 2 24 PBL Cable 2 20 Automatic Cassette Size Sensing Installation Instructions VS 200 Wallstand Installation Operation amp Service Manual 2 Connectother end of bucky cable to generator according to Table 2 2 below Collimator Power Supply Connections Wire Color Linear Il See Figure 2 25 on Linear IV See Figure 2 26 on Table 2 4 Bucky Generator Connections page 2 21 page 2 22 White TS2 20 TS4 6 Green TS2 21 TS4 8 Black TS2 19 TS4 9 Red TS2 22 TS4 7 Jumper s TS2 1 to TS2 4 TS6 12 to TS6 13 TS 2 to TS 3 to TS2 6 TS2 5 to TS2 10 Figure 2 25 Linear II Automatic Cassette Size Sensing Installation Instructions 2 21 VS 200 Wallstand Installation Operation amp Service Manual Figure 2 26 Linear IV 2 22 Automatic Cassette Size Sensing Installation Instructions Addendum Image Receptor Installation CMT Image Receptor Installation This Addendum describes the CMT SmartRAD Digital Imaging Receptor installation on the VS 200 Wallstand When this manual or the CMT SmartRAD manual refer to the bucky both manuals intend those references to refer to the digital imaging receptor in its housing The CMT manual uses the term Flat Panel Display to
118. ing by selecting two mounting ring screw holes that will orient the elbow and Main Cable as planned Mount the Main Cable Mounting elbow to the Mounting Ring Plate as shown below using the two mounting screws Main Cable Exit point Mounting elbow directional orientation on Mounting Ring Figure Addendum 2A 3 CMT Main Cable Exit point Mounting Elbow direction choices 8 Besure all CMT housing covers are installed Slide CMT receptor and cover bracket assembly onto Carriage and secure permanently CMT Image Receptor Installation Addendum 2A 3 VS 200 Wallstand Installation Operation amp Service Manual Note If this wallstand is being installed as a free standing wallstand installing with no support from a back wall proceed with the installation instruction enclosed with the VS200 Floor Mount Kit step 4 on page 1 5 before continuing Note If this wallstand is being equipped with the VS200 Auto Tracking Kit proceed with the installation instruction enclosed with the VS200 Auto Tracking Kit before continuing 9 When all parts are assembled on the wallstand raise the entire wallstand receptor and main cable to the vertical mounting position to allow balancing Lifting the co
119. is accessible dangerous voltage This symbol identifies a protective earth terminal or ground This symbol states that this product is categorized as Type B Type B is defined as Equipment providing a particular degree of protection against electric shock particularly regarding allowable leakage currents and reliability of the protective earth connection if present N This symbol indicates that you must dispose of the VS 200 Wallstand properly according to local laws and regulations Because the VS 200 contains electronic components it must be disposed of separately from household waste When the VS 200 reaches its end of life contact local authorities to learn about disposal and recycling options Table i 1 Definition of symbols found on device labels Definitions i 3 VS 200 Wallstand Installation Operation amp Service Manual 1 4 Safety Conventions Used in this Manual Specific safety information is listed in this manual in the form of WARNING and CAUTION statements Pay close attention to these statements they contain important information on avoiding potential hazards to you or the equipment 1 4 1 Warning Statements indicate hazards or unsafe practices which COULD result in severe personal injury or death appear in bold type have a triangular symbol with an exclamation point above the text are preceded by the word Warning are always found before the step or piece of informatio
120. l 2 2 List of Affected Pages Number Rev Number Rev Number Rev Level Level Level All A All All C All Table ii 2 List of Affected Pages ii 2 List of Affected Pages Introduction 1 1 Introduction This manual provides installation operation and service information for the VS 200 Wallstand equipped with casette tray or digital receptor holder This manual also includes a spare parts list for the wallstand For parts lists for each alternative digital receptor refer to the receptor documentation Introduction 1 1 VS 200 Wallstand Installation Operation amp Service Manual 1 2 VS 200 Wallstand Description The VS 200 Wallstand is designed for general purpose radiography and is ideally suited for modern hospitals urgent care centers clinics and private practices The VS 200 features a smoothly counterbalanced cassette tray holder bucky or digital receptor holder that can be easily moved and locked into place manually The VS 200 offers a full range of motion from standing knee exposures to standing head and neck exposures on the tallest of patients The VS 200 also offers the following options VS 200 Wallstand with regular bucky 110 5010G1 Super Speed Bucky Trayless Auto Load Bucky Del Medical 17 X 17 43 cm X 43 cm Grid Automatic Exposure Control Positive Beam Limitation Auto Cassette Size Sensing Patient Hand Grip Overhead Lateral Full Line of High Quality Grids
121. l Toshiba FD X4343R Image Receptor Installation Addendum E 1 VS 200 Wallstand Installation Operation amp Service Manual 2 Slide front cover 1 in Figure Addendum E 2 up and off wallstand Figure Addendum E 2 Front Cover Removal 3 Unscrew four bottom cover screws 1 in Figure Addendum E 3 and remove bottom cover 2 7 NN Figure Addendum E 3 Bottom Cover Screws Addendum E 2 Toshiba FDX4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 4 Unscrew four lower cover screws 1 in Figure Addendum E 4 and remove lower cover 2 Figure Addendum E 4 Lower Cover Screws 5 If installed remove grid tray 1 in Figure Addendum E 5 Figure Addendum E 5 Grid Removal Toshiba FDX4343R Image Receptor Installation Addendum E 3 VS 200 Wallstand Installation Operation amp Service Manual 6 Remove and save bag 1 in Figure Addendum E 6 Figure Addendum E 6 Bag Removal 7 Unscrew eight base plate mounting nuts 1 in Figure Addendum E 7 and remove base plate 2 Figure Addendum E 7 Base Plate Mounting Nuts Addendum E 4 Toshiba FDX4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 8 The clamp handle 1 in Figure Addendum E 8 can be mounted on the left or right side of the wall stand If it is mounted in the desired position go to step 35 If it is not mounted in the desired position for your applic
122. l Cabinet Assembly 112 5526G1 9 36 9 21 Toshibal Panel Cabinet Loose Parts Kit 112 5527G1 9 38 9 22 Toshiba Panel Junction Box 112 5528G1 9 40 VS 200 Wallstand Installation Operation and Service Manual 9 23 VS200 Wallstand Accessories 9 42 VS 200 Wallstand Installation Operation and Service Manual Safety Information 1 1 Introduction The policy of Del Medical Inc is to manufacture X ray equipment that meets high standards of performance and reliability We enforce strict quality control techniques to eliminate the potential for defects and hazards in our products This equipment provides a vertically adjustable film bucky or digital receptor carriage that positions a patient near an X ray source to acquire X ray images of the desired parts of a patient s anatomy Use of this equipment in any other fashion may lead to serious personal injury The safety guidelines provided in this section of the manual are intended to educate the operator on all safety issues necessary to operate and maintain the wallstand in a safe manner Introduction i 1 VS 200 Wallstand Installation Operation amp Service Manual 1 2 Statement of Liability To prevent excess radiation exposure to patient and operator from either primary or secondary radiation this wallstand must be operated and serviced by trained personnel who are familiar with the safety precautions required
123. l Imaging Receptor Door and Grid Positioning Do not locate a wallstand near a corner where a wall or other obstructions would prevent an X ray room operator from fully removing a grid or removable digital receptor When the uncrating procedure has been completed examine the shipped wallstand and digital receptor parts to determine if the wallstand release brake handle grid door opening and any removable digital receptors are directionally oriented appropriate for the room workflow If any of their orientation needs to be changed see the manufacturer s specifications and installation manuals regarding whether left right re orientation changes can be made The VS 200 wallstand Vertical Carriage and Frame assembly rear panels are designed symmetrically mirrored to allow reversal of left right orientation See Section Converting Left Right Right Left Configurations on page 5 4 From room plans client requests or order specifications determine the left right functional orientation requirements of the Wallstand release brake handle and digital receptor grid door opening The release brake handle and grid door opening should be on the same side for the convenience of the operator If the received parts are oriented differently change their orientation to achieve optimum room workflow efficiency or ask permission from the client to move the wallstand mounting location Refer to the digital image receptor documentation for instructions on ho
124. l risk for both patients and operators For this reason the application of X rays for a given medical purpose must aim at the minimization of radiation exposition to any persons Those persons responsible for the application must have the specific knowledge according to legal requirements and regulations and must establish safe exposure procedures for this kind of systems Those persons responsible for the planning and installation of this equipment must observe the national regulations Equipment Safety Guidelines i 7 VS 200 Wallstand Installation Operation amp Service Manual 1 6 Identification Labels The VS 200 components have manufacturing and certification information affixed The manufacturing label contains The full name and address of the manufacturer of the component e The place month and year of manufacture The model number and serial number of the component The certification label also states that the component complies with either 21CFR Sub chapter J or the applicable DHHS standards under the Radiation Control for Health and Safety Act of 1968 or its equivalent A label may combine both manufacturing and certification information 1 6 1 VS 200 Label The location of the VS 200 identification label is shown in Figure i 1 Figure i 1 VS 200 Identification Label is located on the lower front of the wallstand i 8 Identification Labels VS 200 Wallstand Installation Operation amp Se
125. lation 20 21 22 23 24 25 26 27 VS 200 Wallstand Installation Operation amp Service Manual Unscrew lever nut 1 in Figure Addendum D 16 and lift lever 2 and spacer 3 off of mounting stud Unscrew two inside bracket screws 4 and remove bracket 5 handle guard 6 and handle 7 Remove pulley assembly 8 and place in new position Remove bumper assembly 9 and place in new position Remove handle guide 10 and place in new position Slide handle 7 into bracket 5 Install bracket 5 and secure in place with screws 4 and handle guard 6 Mount lever 2 in new position with spacer 3 amp nut 1 5 2106 7 Figure Addendum D 16 Lock Mechanism Assembly Left amp Right Shown Varian Paxscan 4343R Image Receptor Installation Addendum D 11 VS 200 Wallstand Installation Operation amp Service Manual 28 Reinstall frame 1 in Figure Addendum D 17 with mounting screws Figure Addendum D 17 Frame Installation Addendum D 12 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 29 Reinstall bottom cover 1 in Figure Addendum D 18 with mounting screws 2 Figure Addendum D 18 Bottom Cover Screws 30 Install standoffs 1 in Figure Addendum D 19 Figure Addendum D 19 Standoff Installation Varian Paxscan 4343R Image Receptor Installation Addendum D 13 VS 200 Wallstand Installation Operation amp
126. lred te Ste es br up cte boo ib Oed 6 2 Tools Requifed oio ae ae Gu ate Gee ERE che Cee eee 6 2 Fuses Progeny Bucky i235 some E Wo a eni 6 2 Fuses Potter Villa Bucky 6 2 6 3 Replacing Counterweight Cable 6 4 Tools Required a Pot d rete oen PL 6 4 64 Replacing a emeret eee ee lordo ep ioter eo Ey 6 8 Tools Required 6 8 6 5 Replacing ION Chamber 6 11 TGOlS REQUIRE a Poesie a Doc aude sS yta RUE cay RR 6 11 5 6 Replacing PBL Connector 6 14 Tools Requated o uqa te hued GE ales roi 6 14 6 7 Replacing Brake Cams corse err Re VR ne 6 18 Tools Required ore coeno eec p RE 1E EE 6 18 VS 200 Wallstand Installation Operation and Service Manual 6 8 Replacing Cooling Ramis is E duy nr Reg ewe Res 6 21 Tools Required eege Pipe et acri aet EE 6 21 Chapter 7 Troubleshooting ZA o tED OD sg 7 1 7 2 Troubleshooting Index amp Charts 7 2 7 3 Schematic Troubleshooting 7 6 7 3 1 Ion Chamber Connections 7 7 7 3 2 Bucky Connections e eg ie cout EE EEN EE E Ps 7 8 7 3 3 Cassette Size Sensing Circuit 7 9 Chapter 8 Diagrams amp Electrical Schematics 8 1 Electrical Schematics 8 1 8 2 Configuration Schematic Match Table
127. lstand The schematic covers all of the electrical components in the wallstand Figures 7 2 thru 7 4 show actual diagrams and photos of the components listed on the schematic This allows you to identify the location of the components and translate the fault isolation logic of the schematic into actual testing of components for failure WALL STAND T7 SOURCE N T6 T5 CROSS T4 RET AGINGAN aja Ajai TS T2 T1 lt ION CHAMBER 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT 4 C 22 GA CASSETTE PRESENCE CABLE 70 06525 40FT 9 CND SHLD ION CHAMBER CABLE 73 107 65 65FT Figure 7 1 Overall Wiring Diagram 7 6 Schematic Troubleshooting VS 200 Wallstand Installation Operation amp Service Manual 7 3 1 lon Chamber Connections lon Chamber Connections Figure 7 2 lon Chamber Connections Pin Color Function 1 BLK None 2 BRN Field 2 Select 3 RED Field 1 Select 4 ORG Reset 5 YEL Output 6 GRN Field 3 Select 7 BLU Negative Supply 8 VIO Positive Supply 9 WHT Ground Table 7 1 Pin Definitions Schematic Troubleshooting 7 7 VS 200 Wallstand Installation Operation amp Service Manual 7 3 2 Bucky Connections ww Not GRN WHT RED BLK BRN Used ORG Exp Hold 2 120 VAC AC on Startup Neutral Exp Hold 1 120 VAC Ground No 120 VAC Live Function on Startup Figure 7 3 Bucky Connections 7 8 Schematic Troubleshooting VS 200 Wallstand Installation Op
128. mbined assembled unit requires two people Addendum 2A 4 CMT Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual Wallstand Receptor Balancing The VS 200 wallstand CMT configuration is shipped with ten steel plate weights installed in a pocket on the carriage When the CMT receptor grid and Main Cable is fully installed make any adjustments needed in the number of weights to achieve smooth movement of the fully loaded complete digital imaging receptor carriage assembly 1 Snugly install a cable tie on release brake handle to hold it in the released position to allow easy movement 2 Remove and retain two screws 1 in Figure Addendum 2A 4 holding the Vertical Carriage and Frame Assembly Weight Cover 2 to gain access to the weight holding pocket 3 Figure Addendum 2A 4 Carriage and Frame Assembly top cover 3 Add or remove counterweights to achieve smooth movement 4 Re install Carriage and Frame Assembly top cover with two screws removed in step two 5 Remove the cable tie from the release brake handle 6 Re check for smooth movement and proper brake operation when all covers and the Main Cable are installed 7 Proceed with alignment of the wallstand and receptor per Installation Instructions step 5 Chapter 2 page 2 5 CMT Image Receptor Installation Addendum 2A 5 VS 200 Wallstand Installation Operation amp Service Manual Addendum 2A 6 CMT Image Receptor Installation
129. n VS 200 Wallstand Installation Operation amp Service Manual 13 Observe the pattern reflection on face of collimator as shown in Figure 2 9 Adjust rotational position of wall stand until pattern is centered right to left on collimator Figure 2 9 Pattern reflection 14 Adjust rotational position of wall stand until pattern is centered right to left on collimator A Figure 2 10 Rotational Adjustment 15 With the wallstand aligned in all of its axes mark mounting hole positions with pencil Xwounting Holes F 2 Figure 2 11 Mounting Holes Installation 2 9 VS 200 Wallstand Installation Operation amp Service Manual AN Caution It is up to the installer and the customer to determine the best method for mounting the wallstand to the floor and wall Before mounting wallstand consult with building maintenance supervisor about drilling holes in floor and wall Make sure that there are no hazards under the floor or behind the wall such as pipes conduits or structural cables that can be damaged by drilling holes in floor or wall 16 Move wallstand out of the way Note If this wallstand is being installed as a free standing wallstand mounted with no support from a back wall refer to the enclosed VS200 Floor Mount Kit Installation Instructions 17 Drill mounting holes and fit anchors into place 18 Move wallstand back into position 19 Loosely install mounting bolts 20 Redo steps 7 15 and
130. n Chamber 7 Calibration Procedure for The 61154 Pre Amplifier Board Assemblies Calibration Instructions P N 69329 Table 8 1 List of Diagrams and Schematics Electrical Schematics 8 1 VS 200 Wallstand Installation Operation amp Service Manual The figure below shows the wiring diagram for a VS 200 wallstand equipped with an optional bucky ion chamber and cassette sensing system WALL STAND VS 200 LK RED gt GRN YEL Ou ESSEN RED BLK GRN gt WHT SOURCE CROSS 4 RET Aur Salt lt ION CHAMBER fa LL s n O N Io o o 0 F Or PS ES uU mo anm He Hm lt zo We 5 x m a KE E L o Ll oz Re lt 2 a lt x O Re N N a z o O RE o 6 C 18 GA WALL BUCKY CBL 126 5089G1 65FT Figure 8 1 VS 200 Wallstand Wiring Diagram 8 2 Electrical Schematics VS 200 Wallstand Installation Operation amp Service Manual o o PI 55 9 SS e ao SR og di D SE E on N lt Fb e GRN BRN 2 SE Sa o INS AL BLU 3 ga Linerar Il Linerar IV Sq S9 Collimator Collimator ORG 25 9 Control Box Control Box 4 SS TS 2 TS 4 la ag o eae ws iS 1 RED WHT f f WHT O RTN 5 20 6 ins veli GRN GRN VLtRt 6 L 6 L 21 L 8 b HNVILMHT BLK BLK V Source 7 7 19 9 is BLK RED RED V Up Dn 8 8 22
131. n and secure it open with a cable tie 1 in Figure 6 26 Figure 6 26 Brake Handle Tied Open 6 Slide top of column 1 in Figure 6 27 about halfway through cassette holder sleeve 2 until cams 3 are exposed Figure 6 27 Cams Exposed Replacing Brake Cams 6 19 VS 200 Wallstand Installation Operation amp Service Manual 7 Unscrew cam mounting screw 1 in Figure 6 28 and remove cam 2 8 Place new cam into position and secure with mounting screw Be sure to orient the cam in the same position as the old one 9 Reverse steps to reassemble Be sure to recheck alignment according to Chapter 2 Figure 6 28 Cam Removal 6 20 Replacing Brake Cams VS 200 Wallstand Installation Operation amp Service Manual 6 8 Replacing Cooling Fan Tools Required Medium Flat Tip Screw Driver e Set of Nut Drivers AN Warning Turn off all electrical power to wallstand and all it s peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources other outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Unscrew mounting screws 1 in Figure 6 29 2 Pullfan out of housing i Figure 6 29 Fan Mounting Screws Replacing Cooling Fan 6 2
132. n to which they refer to look like the following example AN Warning This text will describe special safety precautions to follow in order to avoid unsafe practices that COULD result in severe personal injury or death i 4 Safety Conventions Used in this Manual VS 200 Wallstand Installation Operation amp Service Manual 1 4 2 Caution Statements indicate hazards or unsafe practices which could result in minor personal injury or product or property damage appear in bold type have a triangular symbol with an exclamation point above the text are preceded by the word Caution are always found before the step or piece of information to which they refer look like the following example AN Caution This text will describe special safety precautions to follow in order to avoid unsafe practices that could result in personal injury or product or property damage Safety Conventions Used in this Manual i 5 VS 200 Wallstand Installation Operation amp Service Manual 1 5 Equipment Safety Guidelines The following warnings and cautions are specific to the VS 200 Wallstand Read them carefully some of them are not obvious to typical equipment use A Warning Turn off all electrical power to wallstand and all its peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before se
133. needs adjustment Brake cams are worn out or broken Adjust brake according to Sec tion Adjusting Brake Cams on page 5 3 Replace brake cams according to Section Replacing Brake Cams on page 6 18 Up and down movement of cassette hold is difficult Bearing tracks on sides of column are dirty or blocked by obstruction Counterweight cable is frayed Inspect and clean tracks Inspect cable according to Sec tion Checking Counterweight Cables on page 4 3 If necessary replace cable according to Section Replacing Counterweight Cable on page 6 4 Cannot fully remove cassette Cassette restricted by safety latch Completely remove cassette according to Section Com pletely Removing the Cassette Tray on page 3 9 7 2 Troubleshooting Index amp Charts VS 200 Wallstand Installation Operation amp Service Manual Problem Possible Cause Remedy Darks bands on film after exposure See Figure Wallstand is not aligned per Make sure that wallstand is pendicularly to x ray source aligned properly according to Chapter 2 Installation Instruc tions Grid is bad Replace grid according to Sec tion Replacing Grid on page 6 8 Exposure Bands pi he uu ww Troubleshooting Index amp Charts 7 3 VS 200 Wallstand Installation Operation amp Service Manual Problem Possible Cau
134. nsity If necessary adjust the individual gain potentiometers to balance the outputs to give the same mAs reading for each field selected individually Note that individual gain adjustments are multi turn potentiometers A clockwise adjustment to a field gain potentiometer will increase the sensitivity of that field causing the length of the exposure mAs to decrease lonization Chamber Pin outs 61154A Pre amp 9 Pin Sub D Board Pin out Function Pin Out NONE FIELD2SELECT 3 FIELD 1 SELECT AL RESET 44 58 OP 5 6 FIELD3SELECT 6 8 POSITIVE SUPPLY 8 amp 8 9 GROUND 9 Acceptable Power Supply Ranges for 61154A Pre amp referenced to 611544 pin 9 to 15 8VDC External 12VDC 61154A pin 7 11 4VDC to 12 5VDC to 12 5VDC to 5 3VDC Internal 75VDC Measure across 61154A C45 65VDC HV1 to G1 to 85 0VDC JIL Sh ELE db 3i H fo l Bi UP Sar IERI IA TEP ag 61154 Calibration Instructions P N 69329 REV 17 March 2005 Page 4 2005 Advanced Instrument Development Inc Advanced Instrument Development Inc 1011 N 25th Ave Melrose Park IL 60160 U S A Phone 708 343 7777 lonization Chamber Inputs and Output Signal Swith Comments 12VDC Negative Supply None 11 4VDC to 15 75VDC less than 15 mA 12VDC www aidxray com Fax 708 3
135. nstallation Instructions G1 G3 AN Warning Turn off all electrical power to wallstand and all its peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Connect wallstand bucky cable 1 in Figure 2 14 to system bucky cable 2 Figure 2 14 Bucky Cables Bucky Installation Instructions G1 G3 2 13 VS 200 Wallstand Installation Operation amp Service Manual 2 Connect other end of bucky cable to generator according to Table 2 2 below Generator Terminal Connections Color APX 525 Anthem CPI CMP CPI Indico MPX525 ATC 525 ATC725 See Figure See Figure See Figure See Figure 2 15 on 2 16 on 2 17 on 2 18 on page 2 14 page 2 15 page 2 15 page 2 16 1 Brown TB4 4 TB4 4 J4 5 TB2 4 2 Black TB4 2 TB4 2 J4 6 TB2 5 3 Red TB4 1 TB4 1 J4 1 TB3 12 N White TB4 5 TB4 5 J4 4 TB7 2 B6 Yellow w Ground Ground J4 3 Ground Ground Green Stripe Wires in Tubing are Green amp Orange B8 L Blue TB4 3 TB4 3 J4 2 TB2 1 For CPI Indico generators place a jumper between TB9 3 and TB11 2 Also place the jumper plug on JW3 between terminals 4 and 6 Table 2 3 Bucky
136. nterweight 13 Push counterweight about 3 1000 mm back into column with a broom stick or similar tool 14 Reverse steps to reassemble Make sure that cable stays uncrossed and aligned with pulley Also make sure you insert cable between pulley and bracket before reinstalling pulley There is not enough clearance to insert the cable when the pulley is installed Be sure to check alignment to x ray source according to Chapter 2 when setting wallstand back up F Figure 6 9 Counterweight Positioning Replacing Counterweight Cable 6 7 VS 200 Wallstand Installation Operation amp Service Manual 6 4 Replacing Grid Refer to the following instructions for information on how to replace the grid for the regular bucky If the wallstand is equipped with one of the optional digital receptors with grid refer to the corresponding documentation for instructions on how to replace the grid if applicable Tools Required 11 32 nut driver medium phillips head screwdriver Replacing of grid for digital imaging receptors may require tools not listed here See the digital receptor documentation for tools and materials not listed here N Warning Turn off all electrical power to wallstand and all its peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of
137. onnector VS 200 Wallstand Installation Operation amp Service Manual 11 Pull connector and harness 1 in Figure 6 23 out of bracket 2 Figure 6 23 PBL Connector 12 Reverse steps to reassemble Use Figure 6 24 as a wiring guide Figure 6 24 PBL Wiring Diagram Replacing PBL Connector 6 17 VS 200 Wallstand Installation Operation amp Service Manual 6 7 Replacing Brake Cams Tools Required cable tie medium phillips head screwdriver rug or soft surface to lay wallstand down on set of hex wrench AN Warning Turn off all electrical power to wallstand and all it s peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources other outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not zech Remove the wallstand s wall and floor mounting screws Carefully lay wallstand face down on a soft rug or other soft surface 2 3 Unscrew top cover screws 1 in Figure 6 25 and remove top cover 2 4 Loosen two bracket bolts 3 and slide bracket 4 off of top of column 5 Figure 6 25 Top Cover amp Bracket 6 18 Replacing Brake Cams VS 200 Wallstand Installation Operation amp Service Manual 5 Pull brake handle ope
138. or and Grid Positioning 2 2 2 1 5 Uncrating Shipment Checking 2 3 Eeer i a 2 4 2 3 Bucky Installation Instructions G1 G3 2 13 2 4 Automatic Exposure Control Installation Instructions 2 17 2 5 Automatic Cassette Size Sensing Installation Instructions 2 20 Addendum 2A CMT Image Receptor Installation CMT Image Receptor Installation Addendum 2A 1 Mounting digital receptor to wallstand Addendum 2A 2 Wallstand Receptor Balancing Addendum 2A 5 Addendum 2B Canon 40 Image Receptor Installation Canon 40EG Image Receptor Installation Addendum 2B 1 Mounting digital receptor to wallstand Addendum 2B 2 Wallstand Receptor Balancing Addendum 2B 5 Addendum 2C Canon 50 Image Receptor Installation Canon 50G Image Receptor Wallstand Installation Addendum 2C 1 Wallstand Receptor Balancing Addendum 2C 2 Addendum 2D Varian Paxscan 4343R Image Receptor Installation Varian Paxscan 4343R Image Receptor Wallstand Jnstallation s e cbe x tau e aue Addendum 2D 1 Addendum 2E Toshiba FDX 4343R Image Receptor Installation Toshiba FDX 4343R Image Receptor Wallstand Installation snai cw eem RUPEE pee Addendum 2E 1 Chapter 3 Operation 3 1 Safety Precautions iios Re RE RR ERRARE EE EARN 3 1 3 2 Sp cifications 2 P1 dud Radar OO ces e POUR ee cedet Node AO
139. part number is the Del Medical part number used to identify the part for ordering The part description column lists each part name and the quantity column lists the quantity of that part used in that particular assembly Illustrations are shown before the parts list for each assembly Some assembly illustrations require more than one page 9 2 How to Use This Parts List VS 200 Wallstand Installation Operation amp Service Manual 9 3 Commonly Ordered Parts Part Description VS 200 Wallstand Installation Operation amp Maintenance Manual Part number 8000 VS200NM Screw HHMS 10 32 X 1 4 Screw SHSSCP 10 32 X 3 8 Screw PPNHMS SEMS 6 32 Screw PPNHMS 10 32 X 5 16 Standoff 6 32 9 16 LG M F Decal Del Medical Logo Brake Cam RH 250 5006P1 Brake Cam LH 250 5006P2 Counterweight Cable 403 5003P1 PBL Connector Receptacle 1417 0602 Wallstand Cable Assembly Internal 126 5088G1 Wallstand Cable Assembly External 126 5089G1 Loose Parts Kit Consisting of 112 5188G1 Middle Cover 210 5013P1 Bottom Cover 210 5015P1 Top Cover 214 5012P1 Trim Bar Spacer 210 5008P1 Trim Bar 240 5009P1 Front Panel 5500 0494P2 Wallstand Cable Assembly External 126 5089G1 Cover Mounting Bracket 202 5003P1 Top Cover Spacer 232 5001P2 Screw Trim 10 32 X 3 8 100012P3 Screw Trim 6 32 X 1 2 100012P7 751 02 19102511 757 41 19103810 760 22 14205011 760 22 19103111 642 0018P10 408 5099P2
140. pe B 6 X 3 8 1 17 46 170012P35 Nut HEX KEPS 6 32 X 1 4 2 23 46 170015P16 Screw BHMS SEMS 10 32 X 3 8 25 4463 0100 Lubriplate Auto Lube 26 4455 0123 Terminal AMP 52949 6 Spade 12 27 46 170686P2 Sealant Loctite 242 28 203 0305P2 Retainer 1 29 762 20 14206211 Screw PFHMS 6 32 X 5 8 2 30 126 0005G1 Jumper 3 Table 9 9 PBL Tray Bracket Assembly PBL Tray Bracket Assembly 5500 2855 9 21 VS 200 Wallstand Installation Operation amp Service Manual 9 12 Mounting Frame CMT Digital Receptor 112 5402G1 We Figure 9 9 Mounting Frame CMT Digital Receptor 9 22 Mounting Frame CMT Digital Receptor 112 5402G1 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 1 100012P3 Trim Screw 10 32x3 8 2 100012P6 Trim Screw 6 32x5 16 3 203 5150P1 Left Bracket 1 4 203 5150P2 MNL Right Bracket 1 5 203 5151P1 Side Plate 1 6 203 5152P1 Bottom Plate 1 7 203 5153P1 Top Cover 1 8 703 00 05001000 MNL Screw SHCS M5x10 6 9 784 12 19100011 MNL Nut Hex Keps 10 32 2 10 786 50 19000011 Washer SPLITLK STD 10 6 11 720 00 05000001 MNL Nut Hex M5 6 Table 9 10 Mounting Frame CMT Digital Receptor Mounting Frame CMT Digital Receptor 112 5402G1 9 23 VS 200 Wallstand Installation Operation amp Service Manual 9 13 Mounting Frame Canon 40 Digital Receptor 112 5403G1
141. ppermost position it will also increases the minimum required floor to ceiling dimension see Dimensions on page 1 5 for details 1 14 Overhead Lateral Hand Grip Option VS 200 Wallstand Installation Operation amp Service Manual 1 10 Installation of Optional Kits Optional kits are shipped with separate installation instructions Incorporate these installation instructions into this manual for future reference Chapter 9 Illustrated Parts List lists the part numbers for the kit installation instructions should you need a copy Installation of Optional Kits 1 15 VS 200 Wallstand Installation Operation amp Service Manual 1 16 Installation of Optional Kits Installation 2 1 Pre installation Pre planning 2 1 1 Tools required Installation of digital imaging receptors may require electronic equipment and tools not listed here See the digital receptor documentation for additional list of tools diagonal cutters side cutters four anchor inserts and bolts for mounting base to floor size determined by installer medium phillips screwdriver pencil power drill and masonry bit size determined by installer set of hex wrenches set of open end wrenches small flat square or rectangular mirror e small flat tip screwdriver Note Two people are required to perform wallstand installation procedures This procedure assumes that your overhead crane or tubestand is already installed and its collimator can
142. r Y pattern ion chambers commonly used in medical radiographic equipment with sensing fields located at the lung and center spine positions The operator selects the field s desired and positions the anatomy of interest in front of the selected field s Note that for Y pattern ion chambers the two lung fields act together as field A Calibration Test Set Up Select the center field of the ion chamber Set the generator for 100 kVp and maximum backup time For 100 kVp use 8 to 10 inches 20 to 25 cm of water or plastic for a phantom Metals such as copper aluminum or lead are not suitable for use as phantoms Make sure the phantom is homogeneous and completely covers all fields equally Center the x ray beam on the center field Collimate the x ray beam so that it completely covers all three fields but does not extend beyond the limits of the phantom Adjustment Potentiometers TOP TURN GAIN POTS Expos AID AUTOMATIC EXPOSURE CONTROL EJE Cs ADVANCED INSTRUMENT DEVELOPMENT INC gt O IONI N 25TH AVE C MASTER GAIN rei MELROSE PARK IL 60160 U S A N Q O C MASTER GAIN SIDE TURN GAIN POTS All necessary adjustment potentiometers are accessible through the pre amp chassis cover There is no need to open the pre amp cover during normal calibration procedures Master Gain Adjustment Typically the master gain adjustment is the only adjustment needed when installing
143. ration External Heat Generation None Classification Class 1 Type B Aluminum Equivalent Beam Attenuation of the wallstands front panel is 0 7 mm Alu minum Equivalent or Less Temperature Limits Transit Storage Operating 40 F to 158 F 50 F to 95 F 40 C to 70 C 10 C to 35 C Relative Humidity Limits Transit Storage 10 to 100 Operating 10 80 Non Condensing Atmospheric Limits 14 5 inHg to 30 74 inHg 500 hPa to 1060 hPA Weight 200 Ibs 91 Kg Degree of protection against the ingress Ordinary of water Certifications ER C 0120 Classified To UL 60601 1 IEC60601 1 EN60601 1 IEC 60601 2 32 EN60601 2 32 IEC60601 1 3 EN60601 1 3 EN60601 1 2 2000 Certified To CAN CSA C22 2 NO 601 1 Equipment not suitable for use in the presence of flammable anesthetic mixtures with air oxygen or nitrous oxide No user serviceable parts Table 3 1 Specifications Refer to the Digital Image Receptor Documentation for specifications on that portion of the VS 200 Wallstand System 3 2 Specifications VS 200 Wallstand Installation Operation amp Service Manual 3 3 Controls This section describes the controls of the wallstand with regular bucky Figure 3 1 below shows the controls of the wallstand Cassette Tray Holder Cassette Tray Handle Release Brake Handle Figure 3 1 Wallstand Controls 3 3 1 Cassette Tray Handle regular bucky Pull
144. ration amp Service Manual 12 Cutall cable ties 1 in Figure Addendum D 9 on sensor cable 13 Remove screws 2 4 4 Figure Addendum D 9 Grid Sensor Addendum D 6 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 14 Remove screws 1 in Figure Addendum D 10 and remove cover 2 Figure Addendum D 10 Handle Front Cover Removal 15 Remove screws 1 in Figure Addendum D 11 and remove cover 2 Figure Addendum D 11 Handle Side Cover Removal Varian Paxscan 4343R Image Receptor Installation Addendum D 7 VS 200 Wallstand Installation Operation amp Service Manual 16 Remove screws 1 in Figure Addendum D 12 and remove cover 2 Figure Addendum D 12 Side Cover Removal 17 Remove standoffs 1 in Figure Addendum D 13 Figure Addendum D 13 Standoff Removal Addendum D 8 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 18 Unscrew four bottom cover screws 1 in Figure Addendum D 14 and remove bottom cover 2 7 NT Figure Addendum D 14 Bottom Cover Screws Varian Paxscan 4343R Image Receptor Installation Addendum D 9 VS 200 Wallstand Installation Operation amp Service Manual 19 Remove screws 1 in Figure Addendum D 15 and frame 2 Figure Addendum D 15 Frame Removal Addendum D 10 Varian Paxscan 4343R Image Receptor Instal
145. rces are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Remove the wallstand s wall and floor mounting screws 2 Carefully lay wallstand face down on a soft rug or other soft surface 3 Unscrew four back cover nuts 1 in Figure 6 4 and remove back cover Figure 6 4 Back Cover 6 4 Replacing Counterweight Cable VS 200 Wallstand Installation Operation amp Service Manual Figure 6 5 Cable End Disks 5 Unscrew top cover screws 1 in Figure 6 6 and remove top cover 2 Figure 6 6 Top Cover Replacing Counterweight Cable 6 5 VS 200 Wallstand Installation Operation amp Service Manual 6 Remove retaining ring 1 in Figure 6 7 shaft 2 and pulley 3 Figure 6 7 Shaft amp Pulley 7 Unscrew two nuts 1 in Figure 6 8 and remove bracket 2 Figure 6 8 Pulley Bracket 8 Put on work gloves AN Caution Wear work gloves when pulling cable You may injure your hands on a frayed cable if you do not 6 6 Replacing Counterweight Cable VS 200 Wallstand Installation Operation amp Service Manual 9 Pull on cable 1 in Figure 6 9 to drag the counterweight 2 to top of column as shown below 10 Unscrew two nuts 3 and remove screw 4 11 Discard old cable 12 Connect new cable to cou
146. refer to digital imaging receptor components in the CMT receptor housing Our terminology for digital imaging receptors is digital receptor with the associated digital receptor housing It is suggested that you perform the following CMT digital imaging receptor installation procedure while all parts remain horizontal on the floor or workbench An exploded view of a VS 200 Wallstand Vertical Carriage assembly is shown below Figure Addendum 2A 1 Exploded view of the VS 200 Wallstand Vertical Carriage CMT Image Receptor Installation Addendum 2A 1 VS 200 Wallstand Installation Operation amp Service Manual Mounting digital receptor to wallstand 1 Referto the SmartRAD manual Main Cable Connection for mounting positions access to the receptor housing and how to install power and signal wiring 2 Remove and retain left and right cover brackets from the Vertical Carriage assembly They will later be used to mount the CMT receptor housing on the Vertical Carriage Assembly 3 Preassemble the CMT digital receptor and its housing with all internal wiring connected and install all covers See the CMT SmartRAD manual to connect and route internal wiring 4 Using six M5 Allen screws assemble the left and right cover brackets to the CMT housing rear panel keeping the appropriate left right bracket orientation as planned Figure Addendum 2A 2 shows the CMT receptor mounting using six M5 Allen screws
147. reka Linear IV VS200 034 5077S25 0 CPI OTC 3 Crane Eureka Linear II VS200 034 5077S26 Indico 100 Apollo Table 8 2 Configuration Schematic Match Table 8 4 Configuration Schematic Match Table APX 525 X RAY GENERATOR H V TANK CATHODE ANODE JUMPER CONNECTOR PCB 650 0115 3 000R NRK 2 COLLIM INTRLK COMMON XS x COLORS SHOWN FOR TOSHIBA WHTX X RAY TUBE 182 l I f XL l I il I 1 PHASE 2 WAN 3 COMMON 4 THERMAL SW 5 THERM SW COM 1 WALL SELECT 2 WALL FEEDBACK DC 4 CKT COMMON 5 YI7VAC COM K860 FLOOR CEILING MOUNTED TUBESTAND 40 HSID TE HSID 6 1 TABLE SELECT 2 TABLE FEEDBACK 3 TUVAC 4 CKT COMMON 117VAC_COM GRN YEL GRN YEL 40 VSID GROUND STUD SID CABLE 126 520961 PELLE LR ce SUPPLIED W TABLE AEC CARD PCB 124 0126G2 WALL STAND VS 200 BIZI B272 BLK T77SUURCE T6 GRN VETTSZCRUSS 3 Te In IUN CHAMBER 24VDC POWER SUPPLY CABLE COLLIMATOR LINEAR II 8 OVER TABLE COLLIMATOR K COLLIMATOR POWER SUPPLY HEAD Ce LOGIC PS 120 24 RSA Ba YE SA 82 WALL TABLE BOWER GR 2 aer BUCKY 120 230 BREE d 2 P4VDC Y MOTHER PCB dodo 124 0106S 4442 4 24 VACR ATA SI ca al
148. rts VS 200 Wallstand Installation Operation amp Service Manual Problem Possible Cause Remedy Exposure very light very dark Technique not set up cor Make sure that technique is or intermittently poor rectly setup correctly and that proper AEC field is selected ION chamber cable is not Make sure that lon chamber connected securely cable is securely connected to wallstand and generator lon chamber not properly Check for proper voltages at the adjusted ION chamber Refer to the lon chamber manual This manual is included in Chapter 8 of this manual Also make sure that field selection on control panel matches field actuation on chamber If it doesn t reconfig ure the switches on the lon chamber board according to the lon Chamber manual If voltage is absent check the cables between the generator and the ION chamber for conti nuity The pin numbers on each end of each cable match Jump two pins on the female end of each cable and test correspond ing pins on the other end to check continuity AEC control on generator is Troubleshoot according to gen bad erator manual Instructions for replacing the ION chamber are in Section Replacing ION Chamber on page 6 11 Troubleshooting Index amp Charts 7 5 VS 200 Wallstand Installation Operation amp Service Manual 7 3 Schematic Troubleshooting The schematic diagram below can be used to troubleshoot electrical problems with the wal
149. rvice Manual 1 7 Optical fiber components Some of the equipment built in into this X ray system may use optical fiber cables and connections for signal transmission AN Caution Fiber optic components are very delicate Improper handling may cause costly interruptions in operation of the system AN Warning To prevent eye damage never look directly into a fiber optic cable connector or mating adapter Never assume laser power is turned off or the fiber is disconnected at the other end Considering the fact that an optical fiber is a strand of glass about the same diameter as a human hair fiber optic patch cords and connectors are remarkably durable However careful handling will ensure continued high performance and long life Do not pull or kink patch cords as the glass strand in the middle might become damaged or broken Even if the fiber is not permanently damaged a sharp bend will cause excessive signal loss Fiber optic cables work by bending the light signal as it travels But the light can only tolerate so much bending Keep patch cord bend radius no less than an inch Never use tie wraps as you would with electrical cables If there is need for routing connecting and or disconnecting fiber optic cables follow the handling procedures below to minimize the time and expense associated with broken component fibers 1 7 1 How to handle fiber optic components Wear finger cots or gloves Your hands may look clean but
150. rvicing wallstand The components inside of wallstand have power sources outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not AN Warning Do not operate the wallstand in an explosive atmosphere such as anesthetic gas Doing so can cause an explosion or fire hazard causing serious injury AN Warning All of the movable assemblies and patts of this equipment should be operated with care and routinely inspected in accordance with the manufacturer s recommendations contained in this manual Only properly trained and qualified personnel should be permitted access to any internal parts Live electrical terminals are deadly be sure line disconnect switches are opened and other appropriate precautions are taken before opening access doors removing enclosure panels or attaching accessories Do not remove flexible high tension cables from X ray tube housing or high tension generator and or access covers from X ray generator until the main and auxiliary power supplies have been disconnected For all components of the equipment protective earthing means must be provided in compliance with the national regulations i 6 Equipment Safety Guidelines VS 200 Wallstand Installation Operation amp Service Manual AN Warning This wallstand is intended to be used as part of a system for the intended generation of X rays for medical diagnosis X rays generate a potentia
151. screws 1 in Figure Addendum D 3 and remove ION cover 2 Figure Addendum D 3 ION Chamber Cover Screws Addendum D 2 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 4 Unscrew cable clamp nuts 1 in Figure Addendum D 4 and remove clamp 2 5 Unscrew two connector screws 3 and unplug connector 4 Figure Addendum D 4 ION Chamber Screws 6 Unscrew ion chamber mounting screws 1 in Figure Addendum D 5 Figure Addendum D 5 lon Chamber Mounting Screws Varian Paxscan 4343R Image Receptor Installation Addendum D 3 VS 200 Wallstand Installation Operation amp Service Manual 7 Slide ion chamber out as shown below Figure Addendum D 6 Ion Chamber Removal 8 Remove grid tray 1 in Figure Addendum D 7 Figure Addendum D 7 Grid Removal Addendum D 4 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 9 Remove and save bag 1 in Figure Addendum D 8 10 Unscrew nuts 2 and remove handles 3 Save nuts and handles 11 The camp handle 4 can be mounted on the left or right side of the wall stand If it is mounted in the desired position go to step 35 If it is not mounted in the desired position for your application go to the next step Figure Addendum D 8 Handle Removal Varian Paxscan 4343R Image Receptor Installation Addendum D 5 VS 200 Wallstand Installation Ope
152. se Remedy Bucky does not work Bucky fuse is blown Bucky cable is bad or not connected securely Other Check and if necessary replace fuse according to Section Replacing Fuses on page 6 2 Make sure that bucky cable is securely connected to wallstand and generator Check for voltage presence at bucky terminals and ground Refer to Figure 7 3 on page 7 8 If necessary replace cable Consult bucky manual for further troubleshooting instructions The schematics for the bucky are included in Chapter 8 of THIS manual Cassette size sensing does not work Cassette is not fully inserted into holder Collimator not properly cali brated PBL cable is bad or not con nected securely PBL connector is bad Cassette is bad Make sure cassette is fully inserted Make sure that collimator is cali brated according to its manual Make sure that PBL cable is securely connected to wallstand and generator Make sure that cassette is fully inserted into wallstand Then disconnect PBL cable from wall stand Then on PBL cable to wallstand test for and open cir cuit across the following wires BLK WHT RED WHT GRN WHT If an open circuit is found replace connector on PBL bracket according to Section Replacing PBL Connector on page 6 14 Replace cassette Refer to Sec tion Completely Removing the Cassette Tray on page 3 9 7 4 Troubleshooting Index amp Cha
153. stallation Operation amp Service Manual 53 Connect cooling fan cable wires 1 in Figure Addendum D 38 to terminals on TB1 2 The red wire connects to 24VDC on TB1 The black wire connects to 24VDC COM Figure Addendum D 38 Cooling Fan Cable Hookup Addendum D 26 Varian Paxscan 4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 54 Connect sensor cable wires 1 in Figure Addendum D 39 to terminals on TB1 2 Each wire is tagged with corresponding terminal connection Figure Addendum D 39 Sensor Cable Hookup Varian Paxscan 4343R Image Receptor Installation Addendum D 27 VS 200 Wallstand Installation Operation amp Service Manual 55 Reattach junction box cover 1 in Figure Addendum D 40 Figure Addendum D 40 Junction Box Cover 56 Proceed with alignment of the wallstand and receptor per Installation Instructions step 5 Chapter 2 page 2 5 Addendum D 28 Varian Paxscan 4343R Image Receptor Installation Addendum Image Receptor Installation Toshiba FDX4343R Image Receptor Installation This Addendum describes the Toshiba FDX4343R Digital Imaging Receptor installation on the VS 200 Wallstand Tools Required 3 16 Nut Driver 11 32 Nut Driver Diagonal Side Cutters Medium Phillips Tip Screwdriver Metric Hex Wrench Set 1 Unscrew top cover screws 1 in Figure Addendum E 1 and remove top cover 2 Figure Addendum E 1 Top Cover Remova
154. tc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources other outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Unscrew two top cover screws 1 in Figure 6 14 and remove top cover 2 Figure 6 14 Top Cover Screws Replacing ION Chamber 6 11 VS 200 Wallstand Installation Operation amp Service Manual 2 Unscrew four cover screws 1 in Figure 6 11 and remove ION cover Figure 6 15 ION Chamber Cover Screws 3 Unscrew cable clamp nuts 1 in Figure 6 16 and remove clamp 2 4 Unscrew two connector screws 3 and unplug connector 4 Figure 6 16 ION Chamber Screws 6 12 Replacing ION Chamber VS 200 Wallstand Installation Operation amp Service Manual 5 Unscrew ION chamber mounting screws 1 in Figure 6 17 and lift ION chamber 2 out of cabinet 6 Reverse steps to reassemble Figure 6 17 ION Chamber Mounting Screws Replacing ION Chamber 6 13 VS 200 Wallstand Installation Operation amp Service Manual 6 6 Replacing PBL Connector Tools Required 11 32 nut driver diagonal cutters medium phillips head screwdriver small flat tip screwdriver AN Warning Turn off all electrical power to wallstand and all it s peripheral equipment genera
155. te If this wallstand is being equipped with the VS200 Auto Tracking Kit proceed with the installation instruction enclosed with the VS200 Auto Tracking Kit before continuing 10 When all parts are assembled on the wallstand raise the entire wallstand receptor and main cable to the vertical mounting position to allow balancing Lifting the combined assembled unit requires two people Addendum 2B 4 Canon 40EG Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual Wallstand Receptor Balancing The VS 200 wallstand Canon 40EG configuration is shipped with ten steel plate weights installed in a pocket on the carriage When the grid and CXDI 40EG digital receptor and its housing is fully installed adjustments may be needed in the number of weights to achieve smooth movements 1 Snugly install a cable tie on release brake handle to hold it in the released position to allow easy movement 2 Remove and retain two screws 1 in Figure Addendum 2B 4 holding the Vertical Carriage and Frame top cover 2 to access the weight holding pocket 3 See Figure Addendum 2B 4 L Figure Addendum 2B 4 Vertical Carriage Assembly Showing Weight cover 3 Add or remove counterweights to achieve smooth movement 4 Re install Carriage and Frame Assembly top cover with two screws removed in step two 5 Remove the cable tie from the release brake handle 6 Re check for proper brake operation when all covers
156. th Ave Melrose Park IL 60160 U S A Phone 708 343 7777 www aidxray com Fax 708 343 7795 Trex Medical Continental Keithley Ratheon Xonics Compatible jumper configuration Switch Setting Defeat Power Supply Isolation SW1 1 ON Enable Alternate Field Selection SW1 2 OFF Low Active Commands SW1 3 OFF Start Integrate amp Field Selects SW1 4 ON Field Configuration A 1 B 2 C 3 SW2 2 3 4 6 amp 7 OFF SW3 2 OFF Trex Medical Bennett Health Care Manufacturing Compatible jumper configuration Switch Setting Defeat Power Supply Isolation SW1 1 ON Enable Alternate Field Selection SW1 2 OFF Low Active Commands Start Integrate amp Field Selects SW1 4 ON Field Configuration SW2 1 5 amp 8 ON SW3 2 ON Picker Compatible jumper configuration Switch Setting Defeat Power Supply Isolation SW1 1 ON Enable Alternate Field Selection SW1 2 OFF Low Active Commands SW1 3 OFF Start Integrate amp Field Selects SW1 4 ON Field uu A 2 B SW2 1 3 5 6 amp 7 OFF SW3 2 ON 61154 Caibration Instructions P N 69329 REV 17 March 2005 Page 7 2005 Advanced Instrument Development Inc Illustrated Parts List 9 1 Ordering Parts For your convenience replacement parts and accessories can be ordered from Del Medical Systems by fax 24 hours a day Please have the following information available to ensure quick easy and accurate service Your name and telephone number Your P O Purc
157. that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Unscrew four bottom cover screws 1 in Figure 6 1 and remove bottom cover 2 Figure 6 1 Bottom Cover Screws 6 2 Replacing Fuses VS 200 Wallstand Installation Operation amp Service Manual 2 Remove bucky fuse caps 1 in Figure 6 2 or Figure 6 3 and check fuses Replace as necessary n P o 3 1 120 Jo S S S G GS S S S e LL 2 C JO Q Figure 6 3 Potter Villa Bucky Fuse Caps 3 Reverse steps to reassemble Replacing Fuses 6 3 VS 200 Wallstand Installation Operation amp Service Manual 6 3 Replacing Counterweight Cable Tools Required broom stick min 4 1 5 Mi medium phillips head screwdriver retaining ring pliers rug or soft surface to lay wallstand down on set of nut drivers set of open end wrenches work gloves AN Warning Turn off all electrical power to wallstand and all its peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sou
158. tical Frame amp Carriage Assembly 112 5017G1 Sheet 2 of 2 12 9 52 Figure 9 6 Vertical Carriage amp Frame Assembly Sheet 2 of 2 9 14 Vertical Frame amp Carriage Assembly 112 5017G1 Sheet 2 of 2 VS 200 Wallstand Installation Operation amp Service Manual Fig ref Part number Description Qty 4 100012P6 Screw Trim 6 32 X 5 16 1 5 300 5005P1 Handle Lock Release 1 6 114 5013P1 Tie Link 1 7 126 5088G1 Input Cable Assembly 1 8 201 5006P1 Mounting Angle 1 9 201 5096P1 Bumper Bracket 1 10 201 5008P1 Spring Anchor Bracket 2 11 203 5004P1 Frame 1 12 203 5005P1 Lever Guide 1 13 203 5011P1 Trim Weight Cover 1 14 210 5007P1 Mid Cover 1 16 230 5003P1 Bushing Lever Pivot 1 17 236 5010P1 Block Bearing Mounting 1 18 236 5014P1 Plate LK Cable Clamp 1 19 236 5014P2 Plate LK Cable Clamp THRD 1 21 236 5050P1 Handle Stationary 1 22 236 5017P1 Bar Pulley Mounting 1 28 280 5001P1 Lever 1 31 303 0011P2 Cable Clamp Painted 1 32 405 5001P1 Spring Extension 2 33 401 0005P1 Bumper 1 34 403 5001P1 Cable Assembly LK Release 1 35 425 5002P1 Pulley Delrin 1 39 753 40 19103810 Screw SHCS 10 32 X 3 8 3 40 753 40 19106210 Screw SHCS 10 32 X 5 8 2 42 758 40 31203810 Screw Shoulder 5 16 18 X 3 8 1 44 760 22 19103811 Screw PPNHMS 10 32 X 3 8 11 SEMS 46 78
159. tor tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have power sources other outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Manually pull cassette tray out as far as it will go 2 While firmly pressing on limit button 1 in Figure 6 18 pull the cassette tray completely out of the bucky Figure 6 18 Cassette Tray Removal 6 14 Replacing PBL Connector VS 200 Wallstand Installation Operation amp Service Manual 3 Unscrew two top cover screws 1 in Figure 6 19 and remove top cover 2 Figure 6 19 Top Cover Screws 4 Unscrew four bottom cover screws 1 in Figure 6 20 and remove bottom cover 2 7 No Figure 6 20 Bottom Cover Screws Replacing PBL Connector 6 15 VS 200 Wallstand Installation Operation amp Service Manual 5 Slide the front panel 1 in Figure 6 21 straight up and off wallstand 6 Unscrew two side cover screws 2 and remove side cover 3 Figure 6 21 Side Panel amp Front Panel 7 Cutcabletie 1 in Figure 6 22 8 Disconnect wires 2 from terminal 3 9 Unscrew connector screws 4 10 Unscrew four PBL bracket screws 5 and separate bracket 6 from cassette holder Figure 6 22 PBL Bracket Screws 6 16 Replacing PBL C
160. tor clamping plate All wiring must be secured to the auxiliary base along with the optional photo timer cable and then routed through the Stand Cable Cover 5 Use cable tie s to secure all internal and external wiring Sensor cable Ready Lamp cable and Photo timer cable where these wires cables would be separated Addendum 2B 2 Canon 40EG Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 6 See Figure Addendum 2B 2 for wiring routing orientation for a wallstand installation Figure Addendum 2B 2 Universal Imaging cable exit point 7 Remove and retain Vertical Carriage s Left and Right side cover brackets 8 Using the four M6 Allen screws screw the Vertical Carriage s Left and Right side cover brackets 1 in Figure Addendum 2B 3 to the back of the Canon housing 2 in the grid door and brake orientation that you have planned Figure Addendum 2B 3 Canon 40 Left and Right Corner Bracket Mounting Canon 40EG Image Receptor Installation Addendum 2B 3 VS 200 Wallstand Installation Operation amp Service Manual 9 Slide the Left and Right brackets and Canon 40 onto the Carriage assembly Secure with screws removed previously Note If this wallstand is being installed as a free standing wallstand installing with no support from a back wall proceed with the installation instruction enclosed with the VS200 Floor Mount Kit step 4 on page 1 5 before continuing No
161. w to reverse receptor door and grid positions if possible Pre installation Pre planning VS 200 Wallstand Installation Operation amp Service Manual 2 1 5 Uncrating Shipment Checking 1 Use diagonal cutters to cut steel straps 1 in Figure 2 1 Remove straps and top cover 2 Figure 2 1 Steel Shipping Straps Figure 2 2 Unpacking Crate Pre installation Pre planning 2 3 VS 200 Wallstand Installation Operation amp Service Manual 2 2 Installation 2 4 Installation 1 Move wallstand pallet to approximate position where wallstand will be installed AN Caution Wallstand is heavy 200 Ibs 91 kg Two people are required to lift wallstand 2 Lift wallstand 1 in Figure 2 2 out of crate and lean it a against the wall where you intend to install it 3 Remove shrink wrap plastic from wallstand Note If this wallstand is being installed as a free standing wallstand installing with no support from a back wall proceed with the installation instruction enclosed with the VS200 Floor Mount Kit before continuing 4 Remove accessories box 2 in Figure 2 2 from crate The crate contains the manuals and the bucky cable for film based systems The digital receptor system is packaged separately Note If you are installing a digital receptor to the wallstand see the addendum corresponding to your digital receptor before proceeding The addendums listed in Table 2 1 are to be found at the end of t
162. wallstand have power sources outside the wallstand That s why all peripheral equipment must be turned off You could get seriously injured if you do not 1 Unscrew two top cover screws 1 in Figure 6 10 and remove top cover 2 Figure 6 10 Top Cover Screws 6 8 Replacing Grid VS 200 Wallstand Installation Operation amp Service Manual 2 Unscrew four bottom cover screws 1 in Figure 6 11 and remove bottom cover 2 Figure 6 11 Bottom Cover Screws 3 Slide the front panel 1 in Figure 6 12 straight up and off wallstand 4 Unscrew two side cover screws 2 and remove side cover 3 Figure 6 12 Side Panel amp Front Panel Replacing Grid 6 9 VS 200 Wallstand Installation Operation amp Service Manual 5 Unscrew grid clamp screws 1 in Figure 6 13 and remove clamps 2 and grid 3 6 Reverse steps to reassemble Be sure to orient new grid so that etched center line is vertical Figure 6 13 Grid 6 10 Replacing Grid VS 200 Wallstand Installation Operation amp Service Manual 6 5 Replacing ION Chamber For wallstands with digital receptor refer to the manufacturer s specifications and installation manuals for instructions on how to replace ION chamber if applicable Tools Required 5 16 nut driver medium phillips head screwdriver small flat tip screwdriver AN Warning Turn off all electrical power to wallstand and all it s peripheral equipment generator tubestand e
163. ws 2 Figure Addendum E 20 Handle Front Cover Installation Toshiba FD X4343R Image Receptor Installation Addendum E 13 VS 200 Wallstand Installation Operation amp Service Manual AN Caution Handle receptor with great care in the following steps It is very fragile and very expensive 28 Mount plate 1 in Figure Addendum E 21 on receptor 2 with screws 3 Figure Addendum E 21 Mounting Handles on Receptor 29 Mount handles 1 in Figure Addendum E 22 on plate 2 with screws and nuts 3 Figure Addendum E 22 Mounting Handles on Receptor Addendum E 14 Toshiba FD X4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 30 Unscrew screws 1 in Figure Addendum E 23 and remove bar 2 essa Ee T S Figure Addendum E 23 Bar Removal Toshiba FD X4343R Image Receptor Installation Addendum E 15 VS 200 Wallstand Installation Operation amp Service Manual 31 Very carefully lift receptor by handles and place it on studs on wallstand Secure in place with eight nuts 1 in Figure Addendum E 24 32 Remove handles 2 33 Reattached grid bar 3 Figure Addendum E 24 Receptor Mounting Addendum E 16 Toshiba FD X4343R Image Receptor Installation VS 200 Wallstand Installation Operation amp Service Manual 34 For optional ion chamber install it as shown below Figure Addendum E 25 Ion Chamber Installation 35 For optional ion chamber s
164. ws 1 4 Recheck brake function If brake or motion of cassette holder is too tight when pressing the release brake handle reloosen the two screws Insert screwdriver in one screw and use the screwdriver to push the brake screw assembly back out slightly Then retighten the screws Figure 5 1 Brake Assembly Adjustment Screws Adjusting Brake Cams 5 3 VS 200 Wallstand Installation Operation amp Service Manual 5 4 Converting Left Right Right Left Configurations The VS 200 wallstand Vertical Carriage and Frame assembly rear panels are designed symmetrically mirrored to allow reversal of left right orientation of the brake handle The brake handle and grid door opening should be on the same side for the convenience of the operator For wallstands with digital receptor refer to the manufacturer s specifications and installation manuals for instructions on how to reverse receptor door and grid positions if possible Tools Required 3 8 nut driver diagonal cutters medium phillips head screwdriver rug or soft surface to lay wallstand down on set of hex wrenches small flat tip screwdriver AN Warning Turn off all electrical power to wallstand and all its peripheral equipment generator tubestand etc at power sources before servicing wallstand Also make sure that power sources are locked out and tagged Equipment Being Serviced before servicing wallstand The components inside of wallstand have
165. y 112 5501 GRID SHOWN FOR REF ONLY SEE SALES ORDER FOR GRID SPEC SECTION A A SCALE 1 1 APPLY ELECTRICAL TAPE TO BOTTOM OF CLAMP 4PL Figure 9 13 Varian Cabinet Grid Tray Assembly Fig ref Part number Description Qty 1 210 5088P1 Tray Grid 1 2 203 5212P1 Clamp Grid 4 3 201 5168P1 Stop Tray 1 4 763 20 11202511 Screw PFHMSUC 4 40 X 1 4 8 5 762 20 14210011 Screw PFHMS 6 32 X 3 8 2 6 410 5005P1 Threadlocker 242 Blue 1 Table 9 14 Varian Cabinet Grid Tray Assembly 9 30 Varian Cabinet Grid Tray Assembly 112 5501 VS 200 Wallstand Installation Operation amp Service Manual 9 17 Grid Detection Switch Assembly 112 5503 Figure 9 14 Grid Detection Switch Assembly Fig ref Part number Description Qty 1 203 5215P1 Bracker Switch Mounting 1 2 632 0013P1 Switch Limit 2 3 203 5216P1 Bracket Tray Stop 1 4 760 22 1620511 Screw PPNHMS SEMS 8 32 X 1 4 2 5 412 5005P1 Magnetic Strip 3 X 1 8 1 6 760 22 11205011 Screw PPNHMS SEMS 4 40 X 1 2 4 Table 9 15 Grid Detection Switch Assembly Grid Detection Switch Assembly 112 5503 9 31 VS 200 Wallstand Installation Operation amp Service Manual 9 18 Varian Cabinet Loose Parts Kit 112 5504 Figure 9 15 Varian Cabinet Loose Parts Kit 9 32 Varian Cabinet Loose Parts Kit 112 5504