FSH-2, FSH-2A, FSH-2A-99, FSH-2A-99W
Contents
1. LOAD CENTER CIRCUIT BREAKER SUPPLIED BY CUSTOMER SUPPLIED BY CUSTOMER APPLIANCE HOOD AND APPLIANCE CONNECTION APPLIANCE SUPPLY POWER SUPPLIED BY CUSTOMER SUPPLIED BY CUSTOMER SUPPLIED BY CUSTOMER NOTE If not using ILS option the Hood will continue to run and the Appliance will turn off when Any Filter becomes excessively dirty not allowing proper air flow through the Hood Filter is missing or not installed correctly Fire Extinguisher System is activated f using ILS option the Hood and Appliance will turn off when Any Filter becomes excessively dirty not allowing proper air flow through the Hood Filter is missing or not installed correctly Fire Extinguisher System is activated Model FSH 2 FSH 2A Installation FSH 2A 99 amp FSH 2A 99W 2 03 04 Fire Alarm Connection This connection will send a signal the Facility Fire Alarm System that the Hood Fire Extinguisher System has been activated Fire Alarm Connection Remove Cover on Fire Alarm Tie In Box and run appropriate size conduit wire from the Box to the Facility Fire Alarm System Allow enough conduit and wire so the Hood can be accessed for cleaning and servicing 2 Make appropiate connections 3 Reinstall Fire Alarm Tie In Box Cover 2 04 Fryer and Oven Limitations and clearances This section describes various limitations to th
2. ILS only 2 The Fryer underneath the Hood may now be turned on and used OFF 4 02 Hood Filters and Filter Maintenance This section describes each Filter and it s maintenance required 4 02 01 Hood Filter Table Filter i How to remove How to clean How to install Baffle Filter Clean daily Section 4 02 06 Section 4 02 07 section 4 02 08 EAC Filter Clean daily Section 4 02 08 Section 4 02 11 Section 4 02 09 Replace every 30 Never clean only Charcoal Filter days Section 4 02 12 replace Section 4 02 13 P N 30248 Section 4 02 15 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Operation 4 02 02 Baffle Filter Removal 30 Model FSH 2 FSH 2A Operation FSH 2A 99 amp FSH 2A 99W 4 02 03 Baffle Filter Installation Switch arm must be actuated by the Filter as shown 31 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Operation 4 02 04 Baffle Filter Missing If the Baffle Filter is missing or not in place correctly the Filter Missing Light RR will come on See Section 7 02 03 Baffle Filter Installation HOOD POWERED O FRYER POWERED FILTER MISSING PUSH TO STAR
3. 5 0304 ee aun obsess Oe 6 6 2 1 7 2 01 7 2 02 DOCKING WEEN 2 Electrical Requirements e xc Pu SHE T E be RP ac B Wa 2 03 01 Electrical Connections Overview 9 2 03 02 Hood Power Are s 9 2 03 03 Hood and Appliance Interlock Connection 10 2 03 04 Fire Alarm Connection 11 2 04 Fryer and Oven Limitations and clearances 11 2 04 01 Fryer Limitations under FSH 2 FSH 2A 5 2 90 11 2 04 02 Oven Limitations under FSH 2A 99W 12 2 04 03 Fryer Clearances for 5 2 13 2 04 04 Fryer Clearances FSH 2A 14 2 04 05 Fryer Clearances for 5 2 99 15 2 04 06 Oven Clearances 2 9 16 2 05 Fire Suppression 581 17 2 05 01 Fusible Links and Gas Cartridge 17
4. mmzoc 33 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W peration 4 02 09 EAC Fitler Cleaning Do not bend the fins or break the ionizer wires on the EAC as this will prevent the EAC from working properly and potentially void the warranty lonizer Wires 9 Required 1 Mix 1 2 Gallon of a mild non caustic biodegradable degreaser such as Simple Green or Clean Magic with 6 5 gallons of water in the included Soak Tank BR NOTE The mixed solution in the Soak Tank should last up to 30 days without being changed 2 Holding the contact plate on the EAC ER slowly lower the fil ter into the Soak Tank 3 After allowing the EAC to soak for 20 to 30 minutes using the con Ng tact plate lift the EAC up and down approximately 1 to 2 to helo remove the grease residue 4 Slowly remove the EAC from the tank and rinse clean in a sink using hot water 5 Allow the EAC to air dry thoroughly Do not dry the EAC either by running the hood to air dry or by running the appliance to heat dry This could potentially damage the EAC causing improper operation and voiding the warranty 34 Model FSH 2 FSH 2A Operation FSH 2A 99 amp FSH 2A 99W 4 02 10 Charcoal Filter Removal Hood Filter Cover 4 02 11 Charcoal Filter Installaton Hood Filter Cover Switch mus
5. 8 03 Parts List for Wiring Diagram FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W220 50 1 BOARD CONTACT EAC VH UNITS POWER SUPPLY W DRIVER BRD 208 240V SWITCH VACUUM HOSE BARB INDICATOR LIGHT GREEN TERMINAL BLOCK MA106 6 POLE BLOWER ASSY CF A400VH BOX 1 2 UTILITY SWITCH ROCKER 250V 20A DPST SWITCH PLUNGER 250V 15A RELAY 30A 240V 2 POLE BAFFLE FILTER SWITCH ASSY CF 400 500VH MODULE AIR FILTER ALARM AND SHUTDOWN SWITCH SNAP ACTION ROLLER TYPE SONALERT 250V CONTINUOUS BEEP SONALERT 250V INTERMITTENT SWITCH PRESSURE FIREBUTLER 40 5 LED AIR FILTER EAC SWITCH ANSUL SHUTDOWN ALARM 15A 120V CONTACTOR LOAD CENTER BRAID COPPER SHIELDING WIRENUT IDEAL BLUE INDICATOR LIGHT ORANGE INDICATOR LIGHT RED 1 2 9 4 5 6 7 57 Model FSH 2 2 FSH 2A 99 amp FSH 2A 99W Wiring Diagram Notes 58 GILES FOODSERVICE EQUIPMENT Giles Enterprises Inc P O Box 210247 2750 Gunter Park Drive West Montgomery Al 36121 0247 USA 334 272 1457 Service Hotline 1 800 554 4537 USA amp Canada Only FAX 334 272 3561 www gilesent com Form 60200 Release date 07 98 Revision date 11 28 2005 Rev C ECO1006 CSY
6. Repair EAC EAC dirty Clean EAC EAC power supply faulty Replace EAC power supply EAC wires shorted Check voltage Bad contact plate Replace contact plate EAC module faulty Replace EAC module EAC ionizer wire broken or missing Replace ionizer wire Model FSH 2 FSH 2A Parts List FSH 2A 99 amp FSH 2A 99W 7 Parts List This section lists various parts that are available for replacement on the FSH2 FSH 2A FSH 2A 99 and FSH 2A 99W 7 01 Parts Ordering and Service Information you require assistance or need repairs please contact your area developer for a service agency in your area For further assistance please contact the Giles Enterprises Inc factory at the following phone numbers IN THE UNITED STATES CANADA or MEXICO Please call 1 800 288 1555 during normal business hours 8 00AM 5 00PM Central Time Zone For emer gency equipment repair service after normal business hours call 1 800 288 1555 extension 314 IN ALL OTHER COUNTRIES Please call 1 334 272 3528 during normal business hours 8 00AM 5 00PM Central Time Zone For emer gency equipment repair service after normal business hours call 1 334 272 3528 extension 314 INTERNET Please visit our website on the world wide web at www gilesent com The goal of the Giles team of professionals is to provide you with the highest quality of service and assis tance You can help us accomplish this by
7. INCHES MILLIMETERS DOCKING OPENING WIDTH X MODEL LETTER DESIGNATION FOR OPENING INCHES MILLIMETERS FSH 2 A 609 6 FSH 2 B 20 1 8 511 2 13 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Installation 2 04 04 Fryer Clearances for FSH 2A RECOMMENDED TO CEILING Wu TO To E 40 1 16 1016 88 GI E I TTT Fusible Link P N V I i 7 3 4 197 60 2 1 2 63 50 a D cS o N O NS LO 7 11 16 195 84 15 1 4 387 84 EU ALES E N m Se E 9 eX 3 76 20 g g O w 1 0 7 64 1 8 1629 37 68 1 4 1733 84 mi 56 3 8 1431 76 Fryer Only FRONT RICHT SIDE INCHES MILLIMETERS DOCKING OPENING WIDTH X MODEL LETTER DESIGNATION FOR OPENING INCHES MILLIMETERS FSH 2A A 609 6 FSH 2A B 20 1 8 511 2 14 Model FSH 2 FSH 2A Installation FSH 2A 99 amp FSH 2A 99W 2 04 05 Fryer Clearances for FSH 2A 99 Air discharges to the Left and Right Fire Alarm Junction Box 40 1 16 1016 88 MIN TO CEILING N I Fusible Link gt LI OD gt Fire Detection Bracket ui F 2 1 2 63 50 7 13 16 198 00 7 11 16 195 84 3 76 20 98 1 2 2502 65 Fryer Only
8. 24 hours per day The system contains piping nozzles both appliance and plenum and conduit for routing the fusible link cable through the hood 2 05 01 Links and Gas Cartridge Location Fusible Link 285 Degree F Installed at Factory Fusible Link 165 Degree F Supplied amp Installed by SR Ansul SCH see Appliance Link below Appliance Fusible Link If less than 3 76 2 to cooking surface use Fusible Link 165 Degree F Supplied amp Installed by Ansul If more than or equal to 3 76 2 to cooking surface use Fusible Link 135 Degree F Supplied amp Installed by Ansul Appliance Cooking Surface 17 20 Cartridge INCHES MILLIMETERS Supplied amp Installed by Ansul 17 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Installation 2 05 02 Fire Exinguishing Nozzles and Tank Location All nozzles have been factory installed in the proper operating position DO NOT MOVE OR ADJUST Plenum Nozzle 2 Giles P N 46426 S 2 on We 2 Plenum Nozzle s Giles P N 46426 GH d x aA 678 Q P k lt d FSH 2 Appliance Nozzle Giles P N 46426 FSH 2A Appliance Nozzle Giles P N 40131 FSH 2 Appliance Nozzle Giles P N 46426 FSH 2A Appliance Nozzle 25 Giles P N 40131 Tank 1 1 2 Gallon Giles P N 39272 18 Model FSH 2 FSH 2A
9. Installation FSH 2A 99 amp FSH 2A 99W 2 05 03 Manual Pull Diagram This Hood requires use of the Ansul R 102 Standard for a Manual Pull System The Manual Pull System must be mounting a nearby wall and connect to the Hood This Manual Pull System 15 used to active the Fire Extinguisher System from a remote location The Manual Pull System is supplied and installed by Ansul The following illustration is a typical Manual Pull installation Using this basic configuration the Hood may be moved from the wall for Cleaning and Servicing without removing the Manual Pull from the wall 1 2 Conduit from Hood 90 Degree Pulley Ansul Manual Pull Assembly mounted on the wall 90 Degree Pulley 19 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Installation 2 06 Restraining Device Any Fryer placed under this Hood must be secured so that the Fryer can not move from below the Hood The following is an example of a restraining device that may be used The appropiate restaining device will vary depending on the Fryer the restaining device is not supplied with the hood Applionce Wall Spring Hook Attachments Cotterpin Use to Secure Scissor Hook Brocket Attached to Length Adjustment Brackets Scissor Hook Note Be sure to maintain minumum mum clearances see Section 2 04 02 or 2 04 03 after the Restraining Device is installed 20 Model FSH 2 FSH 2A Overview FSH 2
10. deeds 22 EAC Fiter instaladon cords s Pe ete eee 33 miele EE ou va baa mu eau eae REESEN 33 EAC Fider ns Ga E EEE eee he eae 34 Charcoal Filter Removal 25 Charcoal Filter jnstaliaton RR RR RR RR Re 05 Charcoal Filter MISSING see saamas sas gees s kh EH RE DEX S ates ERE HERE S mee 36 Charcoal Replacement Procedure 36 Klee ale 0265 056 IIT TTD 37 Viominiy interlock Cheek eves agua aed u a 37 Quarterly Hood Cleaning o7 Semi Annual Fire Suppression System 5 38 Annual Fire Suppression System Servicing 38 Twelve Year Suppression System 5 38 Maintenance and Service 39 Hood 41 soe Kee aca oe eee vee ey aes Soe SES NR eae 41 Troubleshooting 43 AIroublesnoourig PTOGSOHGS Ev ETE she 43 Parts LISE v u uc ete ee ew 9 9 eee eae R 45 Parts Ordering and Service Informati
11. for Fusible Link and Gas Cartridge Locations Inspect wire rope for wear at pulleys and detectors and replace if necessary oN Record maintenance date and maintain in a permanent file 4 03 04 Annual Fire Suppression System Servicing Same as Semi Annual but all fusible links must be replaced with new fusible links See Section 2 06 01 Fusible Link and Gas Cartridge Locations 4 03 05 Twelve Year Suppression System Servicing Same as Annual except for the following 1 Replace R 102 fire suppression chemical 2 Hydrostatically test the tank and cartridge 3 Flow test the regulator 38 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Operation 2 2 gt KN UO E 2 4 03 06 Rs 77 5 xor Filter Check 6 Fire Suppression System Initial Date Check 5 Quarterly Cleaning 2 Filter Check Fire Suppression System replace Fusible Links nspection performed by a qualified fire equipment company 39 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Notes 40 Operation Model FSH 2 FSH 2A Hood Cleaning FSH 2A 99 amp FSH 2A 99W 5 Hood Cleaning This section describes the cleaning of the hood The hood must be cleaned every 3 months 5 01 Cleaning Interior Disconnect power to the unit Remove the Filter Cover and all Filters from
12. 2 E Model FSH 2 FSH 2A Wiring Diagram FSH 2A 99 amp FSH 2A 99W 8 01 Parts List for Wiring Diagram FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W 208 240 60 1 BOARD CONTACT EAC VH UNITS POWER SUPPLY W DRIVER BRD 208 240V EAC SWITCH VACUUM HOSE BARB INDICATOR LIGHT GREEN TERMINAL BLOCK MA106 6 POLE BLOWER ASSY CF 400VH CF500VH BOX 1 2 UTILITY SWITCH ROCKER ON OFF 250V 20A DPST SWITCH PLUNGER 250V 15A RELAY 30A 240V 2 POLE BAFFLE FILTER SWITCH ASSY CF 400 500VH MODULE AIR FILTER ALARM AND SHUTDOWN SWITCH SNAP ACTION ROLLER TYPE SONALERT 250V CONTINUOUS BEEP SONALERT 250V INTERMITTENT SWITCH PRESSURE FIREBUTLER 40 5 LED AIR FILTER EAC SWITCH ANSUL SHUTDOWN ALARM 15A 120V CONTACTOR LOAD CENTER BRAID COPPER SHIELDING WIRENUT IDEAL BLUE INDICATOR LIGHT ORANGE INDICATOR LIGHT RED 1 2 B 4 3 6 7 e Loch 53 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Wiring Diagram 8 02 Wiring Diagram FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W 208 240 60 1 w ILS I O4 u I 2 I el 33802 0 2 17 05 CONTROL POWER CONTROL POWER LOAD CENTER W ILS NOTE DASHED LINES ARE FIELD WIRED INTERLOCK TIE IN BOX SIZE TO BE DETERMINED AT INS
13. 2 05 02 Fire Exinguishing Nozzles and Tank 18 2705 09 Manual PUN ee ees ose eons 19 2 06 Restraining 20 3 OvervieW 21 3 01 Filter 22 3 02 CONTO Panel 24 3 03 Accessories Included ud du x ue bbe 26 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W 4 4 01 4 02 4 02 01 4 02 02 4 02 03 4 02 04 4 02 05 4 02 06 4 02 07 4 02 08 4 02 09 4 02 10 4 02 11 4 02 12 4 02 13 4 03 4 03 01 4 03 02 4 03 03 4 03 04 4 03 05 4 03 06 5 5 01 6 01 7 01 7 02 7 03 8 01 8 02 8 03 29 OC LO 29 Hood Filters and Filter Maintenance 29 HOOG CCE Ce anu eu earn cada aspa eds eee eae ees ee 29 Barle Filter 30 Baffle Filter 21 Balile Filter MISSING e aa m HOSE 32 Baffle Filter Cleaning 22 EAC Filter UR E an
14. 60 1 4 1530 64 36 913 87 7 58 3 4 985 56 INCHES MILLIMETERS RIGHT SIDE DOCKING OPENING WIDTH X MODEL LETTER DESIGNATION FOR OPENING INCHES MILLIMETERS FSH 2A 99 A 609 6 FSH 2A 99 B 20 1 8 511 2 15 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Installation 2 04 06 Oven Clearances for FSH 2A 99W Air discharges to the Left and Right 40 1 16 1016 88 MIN CEILING Fusible Link Fire Detection Bracket 10 1253 72 2 1 2 63 50 m MIN M lt C EU Ue SZ Ke a D N eu B E B 5 L ND Ca N e 9 gt E EE OVEN ONLY s 762 00 _ o ra MAX poe 52 812 80 E 35 1216 890 30 7 5716 944 96 36 3 16 918 87 FRONT RIGHT SIDE INCHES MILLIMETERS 16 Model FSH 2 FSH 2A Installation FSH 2A 99 amp FSH 2A 99W 2 05 Fire Suppression System The fire suppression system used in your Giles Ventless Hood Fryer is an Ansul R 102 Restaurant Fire Suppression System Standard UL 197 Listed Final installation charging and testing of the system must be performed by an authorized Ansul distributor in accordance with the 5 listing The fire suppression system is designed and UL listed to provide fire protection for cooking appliances such as fryers It protects your units automatically
15. A 99 amp FSH 2A 99W 3 Overview The following section provides brief overview of the components functions and accessories of the Free Standing Hood Model FSH 2 FSH 2A FSH 2A 99 and FSH 2A 99W Please review this section carefully before proceeding any further Filter Area Figure 3 01 Control Panel Figure 3 02 Appliance Centering Bracket Fryer or Oven Area Fryer or Oven not shown 21 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Overview 3 01 Filter Area V Hr CAUTION Al Not Shown 22 Model FSH 2 FSH 2A Overview FSH 2A 99 amp FSH 2A 99W 3 01 Filter Area Item Description Function Used to access the Electronic Air Cleaner EAC and 1 Hood Filter Cover Charcoal Filters This cover must be in place and latched for the unit to operate This Filter helps to remove odors generated during cook ing This Filter should be replaced monthly NEVER attempt to clean a Charcoal Filter Keep a spare filter 2 Charcoal Filter on hand Giles 30248 for quick change out when need ed DO NOT remove the Charcoal Filter while the Hood or the Fryer is operating to prevent contact with electrical parts and avoid electrical shock The EAC Filter is an electrical device which removes grease vapor and smoke generated by the fryer during cooking Power must be turned OFF to the Hood and Fryer before removing the EAC for cleaning The EAC shou
16. EAC Filter is on or EAC Status powered Used to indicate the EAC has become excessively dirty Do WASH Indicator Light not rely upon this light as a signal for routine cleaning of the 2 EAC Status EAC Failure to clean the EAC daily will significantly decrease S the life of the charcoal filter Clean the EAC daily for best per formance CHECK Indicator Light Used to indcate the EAC Filter is no longer cleaning the air EAC Status The EAC Filter must be cleaned or repaired Hood Powered 4 Indicator Light Used to indicate the Hood 15 powered and running Fryer Powered Used to indicate power 15 available to the Fryer under the 5 Indicator Light hood Filter Missing Used to indicate the Baffle Filter or Charcoal Filter is missing Indicator Light or not correctly in place 7 Poner Suites Used to turn power on to the Hood and will allow the Fryer under the Hood to be turned on Used with ILS Interlocking Start units only Used after the Power Switch is in the position push and hold down PUSH AND HOLD TO START Button for 5 seconds allow ing the unit to start This allows the Hood and the Fryer 8 underneath to both shut down the Hood Filters become Button excessively dirty This option is required by some cities Please contact your local code officials to see if this is required in your city Not Shown 2b Model FSH 2 FSH 2A FSH 2A 99 a
17. ENING WIDTH X MODEL LETTER DESIGNATION FOR OPENING INCHES MILLIMETERS FSH 2 A 609 6 FSH 2 B 20 1 8 511 2 FSH2 18 5 8 FSH2 Dj SH E Model FSH 2 FSH 2A Introduction FSH 2A 99 8 FSH 2A 99W 1 03 04 Overall Dimensions for FSH 2A 99W Air discharges to the Left and Right Fire Alarm Junction Box 24 3 16 613 92 TN L 40 1 16 1016 88 MIN TO CEILING lt nd 1 l m A e Fire Suppression Cocked Sight gt Interlock Hole gt Tie In Leads Detection 1 Bracket i 5 d E Service 2 1 LO Se secans Pull Connection N 5 N 15 1 4 387 84 gt Air Flo N EM gt B S mM wW 00 9 s 7 i gt o S Bj gt 00 cw o 35 1 16 890 30 LO 37 3 16 944 98 36 5 16 918 87 FRONT RIGHT SIDE BACK INCHES MILLIMETERS Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Introduction 1 03 04 Regulatory Listings UL US and Canada 1 03 06 Unit Weights Weights Crated Uncrated kg Ib kg 146 327 148 271 454 206 FSH 2A 99W 635 289 480 218 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Installation 2 Installation This section provid
18. FSH 2 FSH 2A ations amp Service Manual FSH 2A 99 FSH 2A 99W Model FSH 2 Giles Enterprises Inc An ISO9001 Registered Company 2750 Gunter Park Drive West Montgomery AL 36109 USA Fax 334 272 3561 Internet www gilesent com Service Hotline Toll Free 1 800 554 4537 USA amp Canada Only FOODSERVICE EQUIPMENT Form No 60200 Release date 07 98 Revision Date 11 28 2005 Rev LIMITED WARRANTY Subject to the terms and conditions of this Limited Warranty as herein stated all Giles Enterprises Inc Foodservice Equipment and parts purchased new from an authorized Giles Enterprises Inc representative are warranted as to defects in material or workmanship for a period of 12 months from the date of installation provided however that with regard to labor costs in connection with this warranty see below All installations must be made by a qualified installing agency in accor dance with all applicable codes and or regulations in the jurisdiction in which installed Limited war ranty coverage is extended to the original owner only and is void if the unit is resold During the Limited Warranty period Giles Enterprises Inc will replace or recondition at its factory any part or parts of this unit which Giles Enterprises Inc inspectors judge defective provided the unit has been subjected to normal usage properly installed operated and serviced This Limited Warranty does not cover cosmetic d
19. FSH 2A FSH 2A 99 and FSH 2A 99W Please check the Serial Plate as shown below for the units Model Name Voltage Hertz and Phase Serial Plate 51 FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Model Wiring Diagram e e KU e eN RN lt Dy Y LL co o lt Y LL lt h Y LL d Y LL E 8 01 3SYHd 1 80 M66 YZ HS4 ee vz HS4 vZ HS4 7 6 4 WVYOVIG SNIMIM 38 OL 3215 q33 331N39 GVO1 3O19V1NOO GOOH p meses 1 Ei 0 0 O 1 3ONVMIN3 321435 3ovia8 990 1831NI 10000000021 Q3MIM 071315 34V SINN 310N VAM MOVIE VAX OZ MOTI3A 3LIHM Lor Waviv 310W3MN MOTI3A ALIHM WIRING DIAGRAM P N 323937 Movia z oN 5 clr H MOTI3A 3LIHM ONISSIA 33114 Q333MOd 3ANJ M3MOd QOOH 0399010 6 39v9 81 53 TV Q310N 5531 310N 5
20. N ALARM 15A 120V CONTACTOR LOAD CENTER SWITCH PUSHBUTTON N O MOM PLUNGER BRAID COPPER SHIELDING WIRENUT IDEAL BLUE INDICATOR LIGHT ORANGE INDICATOR LIGHT RED 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 55 FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Model Wiring Diagram LO N N 9 lt Dy Y LL o lt gu Y LL lt h Y LL d Y LL O E E 8 03 zu 06 040 66 2 54 66 VZ HS4 vZ HSJ 7 64 WVYSVIC 9NIMIM NOILVTIVISNI LV G3NINY3L30 38 OL 3215 M31N39 GVO1 YOLOVLNOD 4 NEG Ee 4 4 4 1313 34V SINN 3 5 0 310N VAM WAN OZ MOTTSA 3LIHM Q3H3MOd M3MOd QOOH aa Lor Wavy 310W33 3 0399010 MOTI3A 3LIHM SISSVHO 5 SHL 1 3Hl 9 9 S3HIM TW N33A138 03193NNO2 Q310N 3SIMM3HIO SSJINN 31ON Lem dvMIS MOTI3A N3349 V WIRING DIAGRAM P N 36306 D 56 ma Model FSH 2 FSH 2A Wiring Diagram FSH 2A 99 amp FSH 2A 99W
21. NG Fire Alarm Junction Box 40 1 16 1016 88 18 457 20 24 3 16 613 92 Air Outlet Fire Damper Suppression Sight Hole 12 304 80 Interlock Tie In Leads Fire Detection Bracket Vol Remote Fire Suppression Service Pull Connection Entrance o 5 15 1 4 387 84 m D SC N M 00 N ca d x s 5 5 37 5 8 954 98 m I 58 3 4 983 56 29 11 16 753 52 RIGHT SIDE BACK INCHES MILLIMETERS DOCKING OPENING WIDTH X MODEL LETTER DESIGNATION FOR OPENING INCHES MILLIMETERS FSH2A Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Introduction 1 03 03 Overall Dimensions for FSH 2A 99 Air discharges to the Left and Right 24 3 16 613 92 Fire Alarm Junction Box lm 40 1 16 1016 88 MIN TO CEILING Fire Suppression Cocked Sight Hole ewen p Cu co N lt Interlock Detection Bracket Remote Fire 5 ression Service Entrance 7 13 16 198 00 15 1 4 387 84 NEN 98 1 2 2502 65 99 CEILING HEIGHT 2514 60 59 5 8 1513 73 37 5 8 954 98 51 13 16 1315 73 EN um 46 3 16 1172 67 E 38 3 4 983 56 FRONT RIGHT SIDE BACK 29 11 16 753 52 INCHES MILLIMETERS DOCKING OP
22. T ON 4 02 05 Baffle Filter Cleaning Procedure The Baffle Filter should be cleaned daily Place the Baffle Filter in a sink and clean with a mild degreaser Dry thoroughly then reinstall in the unit 4 02 06 EAC Filter Removal Hood Filter ia aN 32 Model FSH 2 FSH 2A Operation FSH 2A 99 amp FSH 2A 99W 4 02 07 EAC Filter Installation Hood Filter Cover Filter must align with this pin EAC Air Flow Arrow locatated on the left or right of the EAC Handle and must point up 4 02 08 EAC Filter Status The three indicator lights on the Control Panel display the status of the EAC Filter The EAC Filter is in place and pow ered WASH The EAC Filter is becoming excessive ly dirty and must be cleaned If this light is on for more then 2 minutes an intermittent alarm will sound and power to the Fryer underneath the Hood will be turned off HOOD POWERED FRYER POWERED CHECK Filter is not operating either MISSING the filter is not properly connected to PUSH the power source or It is damaged If ON this light is on for more then 2 min utes an intermittent alarm will sound and power to the Fryer underneath OFF the Hood will be turned off
23. TALLATION 9 208 240 60 1 L1 HOOD POWER L2 HOOD POWER SERVICE ENTRANCE BOX ELECT CUTOFF REMOTE _ INTERRUPT 5 ALARM a x lt L3 m 85 SNISSIA NOTE UNLESS OTHERWISE NOTED ALL WIRES ARE 18 GAGE E 0399010 HOOD POWER O FRYER POWERED RED WHITE MANUAL PUSH TO START AFTER INTERLOCK HOOD ova Movia sf HH A I d SC Fo cj WIRING DIAGRAM FSH 2 5 2 5 2 99 FSH 2A 99W WIRING DIAGRAM P N 33802 D 54 E Model FSH 2 FSH 2A Wiring Diagram FSH 2A 99 amp FSH 2A 99W 8 02 Parts List for Wiring Diagram FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W 208 240 60 1 w ILS BOARD CONTACT EAC VH UNITS POWER SUPPLY W DRIVER BRD 208 240V EAC SWITCH VACUUM HOSE BARB INDICATOR LIGHT GREEN TERMINAL BLOCK MA106 6 POLE BLOWER ASSY CF 400VH CF500VH BOX 1 2 UTILITY SWITCH ROCKER ON OFF 250V 20A DPST SWITCH PLUNGER 250V 15A RELAY 30A 240V 2 POLE BAFFLE FILTER SWITCH ASSY CF 400 500VH MODULE AIR FILTER ALARM AND SHUTDOWN SWITCH SNAP ACTION ROLLER TYPE SONALERT 250V CONTINUOUS BEEP SONALERT 250V INTERMITTENT SWITCH PRESSURE FIREBUTLER 40 5 LED AIR FILTER EAC SWITCH ANSUL SHUTDOW
24. amage and damage due to acts of God accident misuse alter ation negligence abuse of the Giles Foodservice Equipment or the use of unorthodox repair meth ods All parts replaced under this Limited Warranty carry only the unexpired term of this Limited Warranty Limited Warranty service may be furnished only by an authorized Giles Enterprises Inc representative If Limited Warranty service is requested Giles Enterprises Inc will send factory authorized serv Ice representatives to repair recondition replace or inspect units of its manufacture with such labor being rendered without cost to owner for ninety 90 days from the date of installation Otherwise service including labor and transportation charges or other expenses in connection with the removal or installation of any part or parts supplied under this Limited Warranty are specified on the original sales contract between the purchaser and the authorized Giles Enterprises Inc represen tative Giles Enterprises Inc reserves the right to change or improve its equipment and parts in any way without obligation to alter such equipment or parts previously manufactured Giles Enterprises Inc makes no further warranties express or implied including implied warranties of merchantability or fitness for a particular purpose and has no other obligation or liability not specifically stated herein Repair or replacement as provided under this Limited Warranty is the exclusive reme
25. d Ensure the unit 15 positioned a secure safe location Consult an electrician to ensure all electrical specifications have been met and the unit is properly grounded The wiring diagrams contained in this manual should aid your electrician in the installation of your unit The electronic components of the Control Panel are impact sensitive Exercise care around the Control Panel to maintain proper operation DO NOT install the unit next to combustible walls and materials Failure to maintain safe distances may result in fire During cleaning of the unit ee DO NOT steam clean ee DO NOT use products containing chlorine ee DO NOT use abrasive products steel wool or scouring pads DO NOT modify alter add attachments to this equipment Failure to comply with these CAUTION notices may result in equipment property damage and void the warranty NOTE f the crate is damaged upon receipt immediately inspect the unit and notify the carrier of any damage to the unit To aid the electrician an electrical wiring diagram is contained in this manual Refer to the wiring diagram during installation or servicing Comply with all appropriate state and or local heath regulations regarding the cleaning and sanitation of equip ment vii Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Safety Notes viii Model FSH 2 FSH 2A Introduction FSH 2A 99 amp FSH 2A 99W 1 Introduction Congratulation
26. dy Giles Enterprises Inc shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product except to the extent prohibited by applicable law Any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this Limited Warranty Used Giles Enterprises Inc Foodservice Equipment or parts or Giles Enterprises Inc Foodservice Equipment or parts not purchased from an authorized Giles Enterprises Inc representative carry no warranties express or implied Model FSH 2 FSH 2A Table Of Contents FSH 2A 99 8 FSH 2A 99W V OVE VIEW D oe ee a hea ew Hh eh ee nee we Head Specific Safety 5 A8 vi 1 1 1 01 EE 1 1 02 Standard FESSES ease ates 1 1 03 Optional 22 4 peed bene abe ee ede haere es abe de RR P a 1 1 03 2 1 03 01 Overall Dimensions for FSH 2 1 03 02 Overall Dimensions FSH 2A 3 1 03 03 Overall Dimensions 2 99 4 1 03 04 Overall Dimensions for 2 9
27. e fryers and the oven that can be placed underneath the hoods Please note only Electic Fryers and Oven that do not exceed the following limitations and following clearances are approved to be placed under these hoods Gas Fryers Gas Ovens or any other type of appliances are not approved 2 04 01 Fryer Limitations under FSH 2 FSH 2A FSH 2A 99 These Hoods are design for Electric Fryers Only DO NOT USE ANY GAS APPLIANCES UNDER THE FSH 2 FSH 2A FSH 2A 99 Max Shortening Cooking Surface Capacity Ibs per Fryer Hood kW Input FSH 2 20 Fryers only 110 380 Sq In FSH 2A 20 Fryers only 110 380 Sg In FSH 2A 99 20 Fryers only 110 380 Sq In 11 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Installation 2 04 02 Oven Limitations under FSH 2A 99W This Hood is design for Electric Ovens Only DO NOT USE ANY GAS APPLIANCES UNDER THE FSH 2A 99W Hood kW Input Max Oven Temperature FSH 2A 99W 8 Ovens only 450F 12 Model FSH 2 FSH 2A Installation FSH 2A 99 amp FSH 2A 99W 2 04 03 Fryer Clearances for FSH 2 18 457 20 Fusible Link 12 304 80 7 11 16 195 72 6 3 4 171 62 2 1 2 63 50 3 MIN 76 20 01 137 16 2585 30 ol 85 13 16 2128 10 Y x i eO I C D LC o Fryer Only fe D 29 11 16 753 52 FRONT Fry Vat RIGHT
28. es a summary of the procedures necessary for proper installation of your unit To help pre vent personal injury or equipment damage please ensure the following steps are taken 2 01 Location NOTE decibel level of the hood when operating is approximately 65 dB s DO NOT MODIFY ALTER OR ADD ATTACHMENTS TO THIS EQUIPMENT 1 Before unpacking the unit and assembling the unit using the dimensions and clearances shown in section 2 04 03 and 2 04 06 determine the location of the unit 2 Keep the unit and the surrounding area free and clear from combustible materials di Please provide adequate room for servicing and proper operation of the unit Also provide adequate ventilation in the operating area where necessary 4 Before operating make sure the unit is in a secure position and will not move Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Installation 2 02 Unpacking Your unit may arrive enclosed by a wooden crate The Hood is secured to a wooden platform by means of high tensile strength strapping NOTE f the crate is damaged immediately inspect the unit and notify the carrier of any damage to the unit Exercise care when lifting or moving the unit Exercise care when removing the wooden crate from around the unit Failure to comply with these CAUTION notices may result in minor or moderate injury equip ment property damage and void the warranty 1 Carefully cut and re
29. late matter from the air Extinguishing System built into the hood to extinguish an accidental fire from the Fryer installed underneath the hood 1 03 Optional Feature Interlocking Start System ILS Interlocking Start System ILS This system will cause the Hood and the Appliance below the Hood to shut down when the hood filters need to be cleaned or are not properly installed ILS is required by some cities and or states Please check with your local code officials to see if this system 15 required Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Introduction 1 03 Specifications 1 03 01 Overall Dimensions for FSH 2 Fire Alarm Junction Box 24 3 16 613 92 Air Outlet Fire DP 1 64 KO LC Fire Suppression Cocked Sight Hole Fire Detection Bracket Interlock 1 Leads Remote Fire Suppression Service Pull Connection Entrance 104 13 16 2585 30 6 3 4 171 62 29 1 8 739 08 46 1 4 1174 63 X WE 36 1 4 920 20 VW 1 4 ri 29 11 16 755 52 FRONT RIGHT SIDE BACK INCHES MILLIMETERS DOCKING OPENING WIDTH X MODEL LETTER DESIGNATION FOR OPENING INCHES MILLIMETERS FSH 2 A 609 6 FSH 2 B 20 1 8 511 2 5 2 18 5 8 FSH2 Dj SH E Model FSH 2 2 Introduction FSH 2A 99 amp FSH 2A 99W 1 03 02 Overall Dimensions for 2 RECOMMENDED TO CEILI
30. ld be cleaned daily DO NOT remove the EAC Filter while the Hood or the Fryer is operating to pre vent contact with electrical parts and avoid electrical shock EAC Filter The Baffle Filter is the first stage of the grease extraction aircleaning system found on these units It is easily removed for daily cleaning DO NOT remove the Baffle Filter while the Hood or the Fryer is operating to pre vent contact with electrical parts and avoid electrical shock 4 Baffle Filter Used to hold excess grease from the hood This cup should be cleaned daily or as needed Used to hold the Grease Drip Cup place and to pre S vent the cup trom accidentally dropping Located on top of the unit Allow the recommended clearance of 18 or a minimum clearance of 12 between the top of the Exhaust Stack and the ceil Used to detect a fire the Fryer Vat Be careful not to Appliance Fusible Link hit or bump this link Doing so may inadvertently cause the Fire Extinguisher System to activate 7 Exhaust Stack Not Shown 23 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W 3 02 Control Panel POWERED FRYER POWERED FILTER MISSING 24 Model FSH 2 FSH 2A Overview FSH 2A 99 amp FSH 2A 99W 3 02 Control Panel Item Description Function 1 ON Indicator Light Used to indicate the Electronic Air Cleaner
31. liance 2 03 02 Hood Power Connection Connect Hood Power il w Install appropriate Circuit Breakers in Hood Supply Power Box Main Breaker Box See Section 2 03 for required Circuit Breakers Remove Cover on Service Entrance Box and run appropriate size conduit and wire from the Service Entrance Box to the Hood Supply Power box Main Breaker Box Allow enough conduit and wire so the unit can be accessed for cleaning and servicing Make all appropiate connections Reinstall Service Entrance Box Cover Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Installation 2 03 03 Hood Appliance interlock Connection This connection will cause the Appliance installed below the Hood to shut down of the following occurs Any Filter becomes excessively dirty not allowing proper air flow through the Hood e Any Filter is missing or not installed correnctly The Fire Extinguisher System 15 activated Interlock Hood to Appliance 1 Remove Cover on Interlock Tie In Box and run appropriate size conduit and wire from the Interlock Tie In Box to a Hood and Appliance Connection Box Supplied by Customer Allow enough conduit and wire so the Hood can be accessed for cleaning and servicing 2 Make appropiate connections See Diagram below E Reinstall Interlock Tie In Box Cover CONTROL POWER CONTROL POWER HOOD SUPPLY POWER SUPPLIED BY CUSTOMER Ir INTERLOCK RELAY IN HOOD
32. move the plastic shipping wrap and the strapping mentioned above 2 Use pliers to loosen wire hooks which secure the wooden crate around the unit Remove the wooden crate Carefully remove the unit from the shipping platform Your new 5 2 FSH 2A FSH 2A 99 FSH 2A 99W is extremely heavy see Section 1 03 04 for unit weights Great care should be taken in lift ing or moving the unit to prevent personal injury or equipment damage 2 03 Electrical Requirements Consult a qualified electrician to ensure all electrical specifications have been met and that the unit is properly grounded The unit must be adequately and properly grounded Improper grounding may result in electrical shock Always refer to your local electrical code to ensure proper grounding of this or any other electrical equipment Always consult with an electrician or other qualified service person to ensure breakers and wiring are of sufficient rating and gauge for the equipment being operated Improper installation adjustment alteration service or maintenance could result in death or serious injury equip ment property damage and void the warranty Hood Electrical Requirements Hz Phase Breaker FSH 2 208 240 FSH 2A 208 240 FSH 2A 99 208 240 FSH 2A 99W 208 240 Model FSH 2 FSH 2A Installation FSH 2A 99 amp FSH 2A 99W 2 03 01 Electrical Connections Overview Fire Alarm Tie In Box Box Connection to App
33. mp FSH 2A 99W 3 03 Accessories Included Part Description Part Number Overview Function Baffle Filter Used for removing smoke and P N 42300 contaminants from the air EAC Filter Used for removing smoke and P N 20520 contaminants from the air Charcoal Filter P N 30248 26 Used for removing odors from the air Overview 3 03 Accessories Included Part Description Part Number EAC Soak Tank P N 39327 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Function Used for cleaning EAC filter 27 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Overview Notes 28 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Operation 4 Operation This section describes the operation of and the filter maintenance for the Hood 4 01 Hood Operation This section describes how to start the Ventless Hood Make sure all the Filters are in place before operat ing the unit 1 Press the Power Switch to the ON position if ILS then press and hold the Push and Hold to Start switch for 5 seconds the following will occur EJ illuminates indicating the EAC filter is cleaning the air HOOD iu m d FRYER POWERED illuminates indicating the Hood is and powered w PUSH TO START illuminates indicating power is available to the Fryer E underneath the Hood
34. ntial per sonal injury hazards immediately preceding precautionary measures that pertain to subsequent step s Obey all safety messages that follow this symbol to avoid possible injury or death Failure to adhere to safety precautions identified by the safety alert symbol may also void the warranty ndicates an imminently hazardous situation which if not avoided will result in death or serious injury ndicates a potentially hazardous situation which if not avoided could result in death or serious injury ndicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Also used to alert against unsafe practices When used without the safety alert symbol CAUTION indicates a potentially hazardous situation which IT not avoided may result in equipment property damage and void the warranty NOTE dentifies suggested recommended or other noteworthy information Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Safety Specific Safety Precautions For your safety please observe the following precautions when operating or servicing your Giles equip ment Read the following important safety information to avoid personal injury and or damage to the equipment Turn off the unit and unplug the power cord before cleaning or performing maintenance DO NOT hose down the unit s interior or exterior with water Failure to comply with these DANGER notices will res
35. obtaining the following information and having it readily avail able when calling The information is recorded on the Serial Plate attached to the rear of the unit Serial Plate information The area below may be helpful in recording information for use as a quick reference Model Serial Number Phase Voltage 45 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Parts List 7 02 Ventless Hood Front Not shown 46 Model FSH 2 FSH 2A Parts List FSH 2A 99 amp FSH 2A 99W 7 02 Parts List for Front Ventless Hood Front IUS HOOD FILTER ACCESS PANEL ASSY FILTER ACCESS PANEL ASSY pomme o 1 Los pomme o ee eo amen Not shown Not shown and ILS only 47 Model FSH 2 2 FSH 2A 99 amp FSH 2A 99W Parts List 7 03 Ventless Hood Rear Not shown Not shown ILS only 48 Model FSH 2 FSH 2A Parts List FSH 2A 99 amp FSH 2A 99W 7 03 Parts List for Ventless Hood Rear Description Ce ee EECH 2 1 sancu Tm TO menee Not shown Not shown ILS only 49 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Notes 50 Parts List Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Wiring Diagram Wirnng Diagrams The following section contains various Wiring Diagrams for the FSH 2
36. on 45 Ventless Hood FONT 46 Veniless HOOd REI ug uos d xoi E ES XN 48 Wiring 5 51 Wiring Diagram FSH 2 FSH 2A FSH 2A 99 FSH 2A 99W 208 240 60 1 92 Wiring Diagram FSH 2 FSH 2A FSH 2A 99 FSH 2A 99W 208 240 60 1 w ILS 54 Wiring Diagram FSH 2 FSH 2A FSH 2A 99 FSH 2A 99W 220 50 1 56 Table Of Contents Model FSH 2 FSH 2A Safety FSH 2A 99 amp FSH 2A 99W Safety Overview The instructions contained this manual have been prepared to you in learning the proper procedures for installing and servicing your new unit Throughout this manual safety precautions are identified through the use of the safety alert symbol and three signal words DANGER WARNING and CAUTION All safety alert information precedes the step s to which they apply Suggested recommended or other noteworthy information is identified through the use of NOTES Additionally certain words are used to indicate a specific meaning or to add emphasis The following words are used as indicated throughout the manual Shall understood to be mandatory Should understood to be advisory May understood to be permissive Will indicates a future event condition to occur N or Used in conjunction with signal words DANGER WARNING or CAUTION to alert you of pote
37. onds to the test being performed If a problem is found call your service representative 1 Baffle Filter Check With the Power Switch in the OFF position remove the grease baffle Place the Power Switch in the ON position Check appliance power underneath the Hood the appliance should not turn on Turn the Power Switch to the OFF position and reinstall the grease baffle into the hood 2 EAC Filter Check With the Power Switch in the OFF position remove the EAC Place the Power Switch in the ON position wait two minutes Check appliance power underneath the Hood the appliance should not turn on Reinstall the EAC Si Charcoal Filter Check With the Power Switch in the OFF position remove the Charcoal Filter Place the Power Switch in the ON position Check appliance power underneath the Hood the appliance should not turn on Return the Power Switch to the OFF position Reinstall the charcoal filter A Filter Clogged Check Place the Power Switch in the ON position Place a piece of cardboard over half the Grease Baffle Filter Check appliance power underneath the Hood the appliance should not turn on A buzzer will sound in approximately two minutes if the cardboard is not removed Return Power Switch to the OFF position Remove the cardboard 4 03 02 Quarterly Hood Cleaning During cleaning of the unit ee DO NOT steam clean ee DO NOT use products containing chlorine ee DO NOT use abrasive products steel
38. r power source source Circuit breaker tripped Reset Circuit breaker Filter Missing Light on Baffle filter is not installed Install Baffle filter Charcoal filter is not installed Install charcoal filter h Ligh Check or Wash Light EAC shorted Replace or repair EAC EAC dirty Clean EAC High voltage power supply Replace high voltage power faulty supply High voltage wires shorted Correct shorted condition Bad contact plate Replace contact plate Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W 6 01 Troubleshooting Procedures Cont d Problem Fryer or Oven will not turn on e Hood Power Light on e Filter Missing Light on Fryer or Oven will not turn on e Hood Power Light on e Buzzer emitting a continuous tone e Fryer Powereq light off Fryer or Oven will not turn on e Hood Power Light on e Buzzer emitting a pulsating tone Fryer Powereq Light off 44 Probable Cause Baffle Filter missing Troubleshooting Repair Procedure Install Baffle Filter Baffle Filter not installed properly Reinstall Baffle Filter Charcoal Filter missing Charcoal Filter clogged Install Charcoal Filter Replace Charcoal Filter Baffle Filter clogged Clean Baffle Filter Vacuum switch out of adjustment Adjust Vacuum switch only Kinked vacuum line Remove vacuum line kinks Fan running slow Check voltage EAC shorted
39. s on the purchase of your new Giles Free Standing Ventless Hood Model FSH 2 FSH 2A FSH 2A 99 or FSH 2A 99W manufactured by Giles Enterprises Inc Montgomery Alabama USA here after referred to as Giles The Free Standing Ventless Hood is a product of extensive research and test ing Every unit is thoroughly inspected and tested prior to shioment Proper care and maintenance will ensure years of trouble free service The Giles Ventless Hood System is used in conjunction with various listed cooking appliances to accom plish removal of grease vapors and objectionable odors which may be generated during cooking The hood system performs this function through the use of what 15 commonly referred to as an electronic air clean EAC Electronic air cleaners use an electrical charge to remove contaminant s from the air as they pass through the EAC To help protect your investment this equipment we recommend taking a few moments to familiarize yourself with the installation cleaning and maintenance procedures contained in this manual Read these instructions before installation and use Adherence to these recommended procedures minimizes the potential for costly down time and equipment repairs Please retain this manual for future reference 1 01 Construction All of the unit s exterior parts are constructed of stainless steel 1 02 Standard Features Three Stage Filtration uses three different filters to remove particu
40. t be actuated by the Tilter 35 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Operation 4 02 12 Charcoal Filter Missing CC ETE If the Charcoal Filter is missing or not correctly in place the Filter Missing Light RR will come See Section 4 02 11 Charcoal Filter Installation HOOD POWERED O FRYER POWERED FILTER MISSING PUSH TO START ON mmzoc 4 02 13 Charcoal Replacement Procedure Never attempt to clean the Charcoal Filter Replace the Filter The reuse of a Charcoal Filter can cause damage to the unit Replace the Charcoal Filter every 30 days Use Replacement Part No 30248 36 Model FSH 2 FSH 2A Operation FSH 2A 99 amp FSH 2A 99W 4 03 Maintenance This Section describes periodic maintenance for the Ventless Hood System Performance of these proce dures will maintain the unit s efficiency over time A Maintenance and Service Log is provided in this manual see Section 4 03 06 4 03 01 Monthly Interlock Check Your Giles Ventless Hood System incorporates an Interlock System to ensure the unit is operated in a safe and effective manner Testing of the Interlock System should be conducted MONTHLY in the following man ner Use the form located in Section 4 06 06 Maintenance and Service Log place a check in the box that cor resp
41. the hood Using a soft cloth sponge or towel and a mild non caustic biodegradable degreaser clean the entire Hood Plenum area and Filter Channels Exterior remove power from the unit Using a stainless steel cleaner clean all external stainless steel parts Filters To clean and replace Filters see Section 4 02 01 Hood Filter Table 41 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Notes 42 Hood Cleaning Model FSH 2 FSH 2A Troubleshooting FSH 2A 99 amp FSH 2A 99W 6 Troubleshooting This section describes troubleshooting procedures for the FSH 2 FSH 2A FSH 2A 99 FSH 2A 99W Refer to the wiring diagrams in Section 8 for more detailed analysis Flectrical troubleshooting procedures should be performed ONLY by qualified service personnel Death or serious injury will result from contact with energized electrical components e Failure to comply with these DANGER notices will result in death or serious injury equipment property damage and void the warranty 6 01 Troubleshooting Procedures Problem Probable Cause Repair Procedure Hood will not turn on i ud ILS only Push and Hold Hold down Push and Hold button until unit remains button not held for 5 seconds running Power switch bad Replace power switch Connect to proper voltage Improper supply voltage Hood cover not closed Close hood cover Not connected to power Connect to prope
42. ult in death or serious injury equipment property damage and void the warranty Consult a qualified electrician to ensure that ee all electrical specifications and codes are met ee circuit breakers and wiring are of sufficient rating and gauge The unit must be properly grounded and all electrical specifications must be met during installation Improper installation adjustment alteration service or maintenance could result in death or serious injury equip ment property damage and void the warranty DO NOT use store gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance Failure to comply with WARNING notices could result in death or serious injury and equipment property damage and void the warranty The unit must remain in the upright vertical position Exercise care when removing the wooden crate from around the unit DO NOT operate the unit unless you fully understand the components and their intended function see Section Model FSH 2 FSH 2A Safety FSH 2A 99 amp FSH 2A 99W The unit must be adequately and properly grounded Improper grounding may result in electrical shock Always refer to your local electrical code to ensure proper grounding of this or any other electrical equip ment Always consult with an electrician or other qualified service person to ensure breakers and wiring are of sufficient rating and gauge for the equipment being operate
43. wool or scouring pads Remove power from the unit Remove the Hood Filter Cover and all Filters from the hood Using a mild degreaser clean the entire Hood Plenum and Blower Sections The hood must be cleaned every 3 months 37 Model FSH 2 FSH 2A FSH 2A 99 amp FSH 2A 99W Operation 4 03 03 Semi Annual Fire Suppression System Servicing service of the Fire Suppression System is to be conducted by qualified fire equipment personnel As a minimum field inspection of the Fire Suppression System is to be accomplished semi annually by qualified fire equipment service personnel Such maintenance shall consist of the following Consult the Giles Enterprises Design Installation Recharge and Maintenance Manual for complete servicing guidelines Place fire extinguishing system locking bar on fire system when servicing hood 1 Remove charging cartridge inspect gasket for cuts and elasticity coat gasket with extreme tempera ture grease and reinstall See Section 2 06 01 Fusible Link and Gas Cartridge Locations 2 Remove tank verify chemical is at proper level clean and coat O ring with extreme temperature grease and reinstall See Section 2 06 02 Fire Extinguisher Nozzle and Tank Locations Check all nozzles to insure they are free of cooking grease buildup Test the remote manual pull station for activation and wear Install test link and cut to simulate automatic actuation Clean and inspect fusible links See Section 2 06 01
Download Pdf Manuals
Related Search
Related Contents
Projeto Básico de Salas Limpas Craftsman 38514 Lawn Mower User Manual MooreCo 27623 Sony Memory Stick Gate User's Manual Trust Tecla Wireless Multimedia Keyboard & Mouse LG LX610 Data Sheet Öffnen - Loctite KOHLER K-T134-4D-CP Installation Guide Belkin 8820-00110ea Automobile Accessories User Manual Nissan CVT SIC0697 User's Manual Copyright © All rights reserved.