1. A CAUTION notice denotes a haz ard It calls attention to an operat ing procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly per formed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated condi tions are fully understood and met This Note sign denotes important information It calls attention to a procedure practice or condition that is essential for the user to understand Safety Summary Terminal Adapter The following general safety precautions must be observed during all phases of operation service and repair of this instrument Failure to comply with these precautions or with specific WARNINGS given elsewhere in this manual may impair the protection provided by the equipment Such noncompliance would also violate safety standards of design manufacture and intended use of the instrument Keysight Technologies assumes no liability for the customer s failure to comply with these precautions DO NOT Operate in an Explosive Atmosphere Do not operate the instrument in the presence of inflammable gasses or fumes Operation of any elec
2. attached to the E5061B Network Analyzer Figure 1 16201A Terminal Adapter attached to E5061B Network Analyzer Terminal Adapter Introduction 1 Checking the Shipment After you receive the terminal adapter perform checking when you unpack the shipment according to the following procedure Step 1 Check that the packing box or shock absorbing material used to pack the terminal adapter has not been damaged Ifthe packing box orshock absorbing material has been damaged leave the packing box and shock absorbing material as is until other inspection items are checked as follows Step2 Check the packaged items supplied with the terminal adapter for any damage or defect Step 3 By referring to the furnished contents list check that all packaged items supplied with the terminal adapter are received as per the specified options Step 4 After checking if one of the following applies contact your nearest Keysight Technologies sales and service office 1 The packing box or shock absorbing material used to pack the terminal adapter has been damaged or the shock absorbing material has traces where extreme force has been applied 2 A packaged item supplied with the terminal adapter has mechanical damage or defects 3 A packaged item supplied with the terminal adapter is missing 4 A fault has been detected in the subsequent operation check of the terminal adapter If an abnormality is detected in step 1 contact the
3. Keysight 16207 A Terminal Adapter Operation and Service Supplemental KEYSIGHT Information TECHNOLOGIES NOTICE This document contains references to Agilent Technologies Agilent s former Test and Measurement business has become Keysight Technologies For more information go to www keysight com KEYSIGHT TECHNOLOGIES Notices O Keysight Technologies 2010 2015 No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or transla tion into a foreign language without prior agreement and written consent from Key sight Technologies as governed by United States and international copyright laws Manual Printing History The manual s printing date and part num ber indicate its current edition The printing date changes when a new edition is printed minor corrections and updates that are incorporated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated November 2010 Edition 1 February 2015 Edition 2 Manual Part Number 16201 90000 Edition Edition 2 February 2015 Printed in Malaysia Keysight Technologies 1400 Fountaingrove Parkway Santa Rosa CA 95403 USA Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Safety Notices CAUTION
4. Product maintenance agreements and other customer assistance agreements are available for Keysight Technologies products For any assistance contact your nearest Keysight Technologies Sales and Service Office Addresses are provided at the back of this manual Terminal Adapter Contents 1 Introduction Overview 10 Checking the Shipment 11 Specification 12 2 Operation amp Service Regional Sales and Support Offices Terminal Adapter Terminal Adapter KEYSIGHT TECHNOLOGIES Keysight 16201A Terminal Adapter Operation and Service Manual 1 Introduction Overview 10 Checking the Shipment 11 Specification 12 The purpose of this manual is to provide you the necessary information to use the Keysight 16201A Terminal Adapter efficiently 1 Introduction Overview 10 The Keysight 16201A Terminal Adapter converts the E5061B Network Analyzer N type connector Port 1 into a 7 mm terminal configuration As a result various Keysight test fixtures with a 7 mm terminal connector can be used with the E5061B This allows you to make an accurate and stable impedance measurement using the E5061B Option 005 Impedance Analysis The procedure of checking the shipment of 16201A Terminal Adapter is provided in Checking the Shipment The specification of the terminal adapter is listed in Table 1 The list of accessories supplied is furnished in the shipment of the 16201A Figure 1 shows the Keysight 16210A Terminal Adapter
5. acility designed by Keysight Technologies The Buyer shall prepay shipping charges to Keysight Technologies and Keysight Technologies shall pay shipping charges to return the product to the Buyer However the Buyer shall pay all shipping charges duties and taxes for products returned to Keysight Technologies from another country Keysight Technologies warrants that its software and firmware designed by Keysight Technologies for use with an instrument will execute its programming instruction when property installed on that instrument Keysight Technologies does not warrant that the operation of the instrument or software or firmware will be uninterrupted or error free Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Buyer Buyer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance No other warranty is expressed or implied Keysight Technologies specifically disclaims the implied warranties of merchantability and fitness for a particular purpose Exclusive Remedies The remedies provided herein are Buyer s sole and exclusive remedies Keysight Technologies shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any other legal theory Assistance
6. bols used on the instrument or in manuals are listed below A G PHo Instruction Manual symbol the product is marked with this symbol when it is necessary for the user to refer to the instrument manual Alternating current Direct current On Supply Off Supply In position of push button switch Out position of push button switch A chassis terminal a connection to the instrument s chassis which includes all exposed metal structure Standby Terminal Adapter Terminal Adapter Certification Keysight Technologies certifies that this product met its published specifications at the time of shipment from the factory Keysight Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology to the extent allowed by the Institution s calibration facility or by the calibration facilities of other International Standards Organization members Warranty This Keysight Technologies instrument product is warranted against defects in material and workmanship for a period of one year from the date of shipment except that in the case of certain components listed in this manual the warranty shall be for the specified period During the warranty period Keysight Technologies will at its option either repair or replace products which prove to be defective For warranty service or repair this product must be returned to a service f
7. company that transported the terminal adapter as well as your nearest Keysight Technologies sales and service office For inspection by the transport company save the packing box shock absorbing material and packaged items as you received them Terminal Adapter 11 1 Introduction Specification 12 The specification of the 16201A Terminal Adapter is as shown in Table 1 Table 1 Specification Applicable Instruments 16201A Terminal Adapter Maximum Voltage 42 V peak max AC DC Operating temp 5 C to 40 C nyiraman humidity 20 to 80 at wet bulb temperature lt 29 C non condensing Non operating temp 10 C to 60 C EIVIOMne humidity 20 to 90 at wet bulb temperature lt 40 C non condensing Dimensions 165 W X 200 D X 80 H mm Weight 930 g Only the body of 16201A Terminal Adapter KEYSIGHT TECHNOLOGIES Keysight 16201A Terminal Adapter Operation and Service Manual 2 Operation Service The operation information is described in the E5061B Network Analyzer Help under Option 005 Impedance Analysis section The E5061B Network Analyzer Help is available at the following Keysight website http www keysight com find e5061b manual The part numbers of all replaceable parts are also provided at the same site Do not attempt to disassemble any parts that is not included in the list The listed parts can be ordered from yo
8. tion 2 February 2015 KEYSIGHT WD TECHNOLOGIES 16201 90000 www keysight com
9. trical instrument in such an environment clearly constitutes a safety hazard Keep Away from Live Circuits Operators must not remove instrument covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with the power cable connected Under certain conditions dangerous voltage levels may remain even after the power cable has been disconnected To avoid injuries always disconnect the power and discharge circuits before touching them DO NOT Service or Adjust the Instrument Alone Do not attempt internal service or adjustment unless another person capable of rendering first aid and resuscitation is present DO NOT Substitute Parts or Modify the Instrument To avoid the danger of introducing additional hazards do not install substitute parts or perform unauthorized modifications to the instrument Return the instrument to a Keysight Technologies Sales and Service Office for service and repair to ensure that safety features are maintained in operational condition Dangerous Procedure Warnings Warnings such as the example below precede potentially dangerous procedures throughout this manual Instructions contained in the warnings must be followed Dangerous voltage levels capable of causing death are present in this instrument Use extreme caution when handling testing and adjusting this instrument Safety Symbols General definitions of safety sym
10. ur nearest Keysight Technologies Sales and Service Office Ordering information must include the Keysight part number and the quantity required 2 Operation amp Service 14 Terminal Adapter Regional Sales and Support Offices For more information about Keysight Technologies test and measurement products applications services and for the current sales office listing visit our web site http www keysight com find tmdir You can also contact one of the following centers and ask for a test and measurement sales representative United States Australia New Zealand Test and Measurement Call Center tel 61 3 9210 5555 Australia tel 1 800 452 4844 fax 61 3 9210 5899 fax 1 888 900 8921 tel 64 4 939 0636 New Zealand fax 64 4 972 5364 Canada Asia Pacific Test and Measurement Call Center tel 65 6375 8100 tel 1 877 894 4414 fax 65 6836 0252 fax 1 888 900 8921 E mail tm_asia keysight com China tel 800 810 0189 fax 800 820 2816 Europe tel 31 20 547 2323 fax 31 20 547 2390 Japan Call Center tel 0120 421 345 tel 81 426 56 7832 fax 81 426 56 7840 Korea tel 82 2 2004 5004 fax 82 2 2004 5115 Latin America tel 305 269 7500 fax 305 269 7599 Taiwan tel 0800 047 866 fax 0800 286 331 1 As of 21 01 04 16 Terminal Adapter This information is subject to change without notice O Keysight Technologies 2010 2015 Edi