Home
EEEA135A - Snap
Contents
1. TEEEA135A0 4 25 2005 REV S Page 25 of 37 3 CLICK ON PRINTERS 4 VERIFY THAT THE CORRECT PRINTER ICON IS THERE AND IS SET TO BE THE DEFAULT PRINTER OTHERWISE REISINSTALL THE PRINTER DRIVER USING THE OKIDATA B4200 PRINTER DRIVER CD RECEIVED WITH THE PRINTER FOR INSTALLING THE PRINTER DRIVERS PLACE THE CD IN THE DVD DRIVE WAIT FOR THE INSTALL MENU TO BE DISPLAYED ON THE SCREEN SELECT INSTALL AND FOLLOW SCREEN INSTRUCTIONS VERIFY THAT THE PRINTER IS SETUP AS THE DEFAULT PRINTER LOG OUT AS PC AND LOGIN AS OBIS AND VERIFY THAT PRINTER PRINTS THE REQUIRED REPORTS CORRECTLY NO POWER BAD POWER SUPPLY OR LOOSE e CHECK THE PRINTER POWER CORD FROM THE PRINTER DOES NOT POWER OR USB CONNECTIONS PRINTER TO THE COMPUTER AND VERIFY THAT IT INITIALIZE IS PROPERLY CONNECTED CHECK PRINTER POWER SWITCH SHOULD BE IN THE ON POSITION CHECK USB CONNECTION FROM THE PRINTER TO THE BACK OF THE COMPUTER AND VERIFY THAT IT IS CONNECTED SECURELY e REPLACE PRINTER BAR CODE SCANNER MALFUCTIONS PROBLEM CAUSE SOLUTION DOES NOT SCAN BAR CODE READER NOT e REPROGRAM THE 2D YELLOW BAR CODE SCANNER CODES PROGRAMMED CORRECTLY USING THE SETUP SHEET INCLUDED IN THE INSTALLATION INSTRUCTIONS TEEEA136A0 REV E EN pasi TOWEL TO CLEAN THE BAR CODE READER LENS BAR CODE READER NOT e VERIFY THAT THE BAR CODE READER IS CONNECTED TO CONNECTED TO THE CORRECT THE COMM Port COMM Port WRONG BAR CODE SCANNER VERIFY THE PART NUMBER FOR THE BAR C
2. gt t lt a e a lt 4 P N EAEO032L51A TO ANALYZER Figure 4 OBDII Reader Label 56 Attach the DB9 to DB25 Serial Port Adapter to the connector the rear panel labeled COM 1 57 Locate the Remote Control 7009E9321 30 Remove the rear cover from the remote control Place the two batteries in the Remote Control being careful of polarity Place the rear cover back on the Remote Control and secure with the four screws 58 Place the Remote Control in the Keyboard Drawer 59 Attach the Unit s Power Cord to the outlet on the rear of the Unit 60 Re attach the computer rear panel using the six that were removed in step 3 Lock the compartment 61 Referring to Figure 5 mount the Storage Brackets using the screws provided Figure 5 Storage Bracket Mounting HARDWARE SETUP COMPLETE TEEEA135A0 4 25 2005 REV S Page 6 of 37 BIOS SETUP Power up the unit by placing the power switch on the rear panel to the 1 position Power up the computer by pressing the On Off switch on the front of the computer While the analyzer is booting press F2 to enter the BIOS Setup If Windows is displayed then you must shut down Windows and restart the computer to try again 4 analyzer may prompt for a BIOS Password If so enter the password and press Once in the BIOS Main Menu cursor down to the Boot Sequence option and press Ensure that the Boot Sequence i
3. SETTING UP WINDOWS 2000 SOFTWARE NOTE NOTE NOTE NOTE pr se 2 Iw x FOR RE IMAGING THE HARD DISK ON THE GX 150 COMPUTER USE THE SOFTWARE INCLUDED WITH THE EAK0252L 21 Kir FOR RE IMAGING THE HARD DISK ON THE GX 260 COMPUTER USE THE SOFTWARE INCLUDED WITH THE EAK0252L22A KIT FOR RE IMAGING THE HARD DISK ON THE GX 270 COMPUTER USE THE SOFTWARE INCLUDED WITH THE EAK0252L23A KIT ENSURE THE COMMUNICATIONS BOX IS POWER UP BY OPENING THE STORAGE COMPARTMENT DOOR AND ENSURING THE FAN IS RUNNING IF IT IS NOT POWER IT UP NOW Identify the computer as a GX 150 or a GX 260 or a GX 270 before starting this procedure Turn On the analyzer Press F12 when the Dell logo appears during boot up Next you should see a Boot Device Menu Use one of the following For GX 150 insert the GX 150 Dell OBIS Re lmage Utility Floppy Disk 3 11226BUSD2 into the floppy drive and insert the GX 150 Dell OBIS Utility CD 3 11226CUSC3 Disk 1 of 2 into the DVD ROM drive For GX 260 insert the GX 260 Dell OBIS Utility floppy disk 3 35426BUSD1 into the floppy drive and insert the GX 260 Dell OBIS Utility CD 3 35426CUSC2 i Disk 1 of 2 into the DVD ROM drive For GX 270 insert the GX 270 Dell OBIS Utility Floppy Disk 3 38626BUSD 1 into the floppy drive and insert the GX 270 Dell OBIS Utility CD 3 38626EUSCA Disk 1 of 2 into the DVD ROM drive Press
4. 7 COM H Barcode Reader COM6 27 COM L OBDII Key 27 Communications Port 1 Communications Port COM2 ECP Printer Port LPT1 amp SCSI and RAID controllers lt 5 Sound video and game controllers HE J Storage volumes 2 Systern devices Universal Serial Bus controllers Figure 8 E Device Manager Action View gt m er m 03339821 H Computer 9 Disk drives H Display adapters Ez 5 DVD CD ROM drives Floppy disk controllers H E Floppy disk drives IDE ATA ATAPI controllers H Keyboards 1 9 Mice and other pointing devices 3 Modems 188 Monitors OBIS devices OBIS devices COM amp LPT C Gas Cap Tester 11 27 Dynamometer 10 7 COM H Barcode Reader 27 COM L OBDII Key COM8 E Communications Port COMI 27 ECP Printer Port LPT1 z SCSI and RAID controllers 4 Dr E RH 1 lt Sound video and game controllers Comm Port Labels should read COM C Gas Gap Tester COMXX COM E Dynamometer COMXX COM H Barcode Reader COMXX COM L OBDII Key COMXX El Figure 9 8 Write the COMXX values assigned to Gas Cap Tester Barcode Reader and OBDII Key 9 Close this dialog by clicking on the X in the upper right hand corner NOTE ONCE THE PROCEDURE IS COMPLETE STORE ALL TH
5. 2 for GX 260 or GX 150 or Press 3 for GX 270 to highlight Diskette Drive and then press ENTER When text appears on the screen press the Space Bar key each time when prompted to Strike a key when ready to advance through the license agreement Select Continue on the Power EZ Restore screen Select Yes on the Warning window to continue EZ Restore will start to load the software to the hard drive and then For GX 150 Insert media 2 containing file Y GX1500S 002 into drive Y pop up window will appear remove the GX 150 Dell OBIS Re lmage Utility CD 3 11226CUSC3 1 of 2 and insert GX 150 Dell OBIS Utility CD 3 11226CUSC4 2 of 2 into the DVD ROM Drive For GX 260 Insert media 2 containing file Y GX2600S 002 into drive Y pop up window will appear remove the GX 260 Dell OBIS Utility CD 3 35426CUSC2 1 of 2 and insert GX 260 Dell OBIS Utility CD 3 35426CUSC3 2 of 2 into the DVD ROM Drive For GX 270 Insert media 2 containing file Y 1GX27008S 002 into drive Y pop up window will appear remove the GX 270 Dell OBIS Re lmage Utility CD 3 38626EUSCA 1 of 2 and insert GX 270 Dell OBIS Re Image Utility CD 3 38626EUSC5 2 of 2 into the DVD ROM Drive 11 Select OK and the CD will continue to load to the hard drive 12 NOTE THIS WILL TAKE APPROXIMATELY 10 MINUTES TO LOAD 13 When the Reboot window or an prompt i
6. INFORMATION 11 VERIFY AND CORRECT AS NECESSARY THE VID PHONE TEEEA135A0 4 25 2005 REV S Page 30 of 37 NUMBER AND THE ANALYZER PHONE NUMBER IF BOTHE ARE CORRECT THEN PERFORM THE NEXT STEP 12 FROM THE MAIN MENU SELECT MANUFACTURER S TECHNICIAN MENU 5 13 ENTER DAILY SERVICE CODE AND PRESS F 10 14 SELECT DiAGNOSTIC MENU 2 15 FROM THE DIAGNOSTIC MENU SELECT NETWORK COMMUNICATION DIAGNOSTICS 16 FROM THE NETWORK COMMUNICATION DIAGNOSTICS SELECT MODEM DIAGNOSTICS 17 VERIFY THAT THE COMPUTER IS CONNECTED USING A TELEPHONE LINE TO A TELEPHONE JACK A SUCCESSFUL MODEM TEST WILL RETURN BACK TO NETWORK COMMUNICATION DIAGNOSTICS MENU PAGE IF THE MODEM IS BAD OR NOT WORKING COMMUNICATION ERROR WILL BE REPORTED REPLACE COMPUTER GAS CAP TESTER MALFUNCTIONS PROBLEM CAUSE SOLUTION CANNOT SOFTWARE POWER SWITCH TO VERIFY THAT THE COMM PORTS ARE SET UP CALIBRATE GAS OFF COMM PORTS NOT SET UP CORRECTLY IN SOFTWARE PERFORM THE FOLLOWING CAP TESTER CORRECTLY IN SOFTWARE OR STEPS BAD COMMUNCIATIONS PORT EXIT FROM THE OBIS PROGRAM C LOG IN AS EQUISERV RIGHT CLICK ON MY COMPUTER ICON ON WiNDOWS 2000 DESKTOP SELECT PROPERTIES FROM MENU BY LEFT CLICK OF THE MOUSE LEFT CLICK ON THE HARDWARE FOLDER TAB CLICK ON DEVICE MANAGER BUTTON EXPAND PoRTs COM amp LPT PROPERTIES BY CLICKING ON SIGN NEXT TO THE LABEL VERIFY WITH THE PICTURES BELOW FOR COMM PORT LABELS NOTE THAT THE VALUE F
7. List above Identify each piece to ensure that it is included and set aside for assembly in the next steps Once the packaging has been removed from the unit push it to the spot where you will work on it LOCK THE CASTERS Remove the six retaining screws from the computer compartment rear panel Using a 225 key unlock and remove the computer compartment rear panel and set it aside Using the key shipped with the cabinet unlock and open the front computer compartment door Standing in front of the unit locate the storage compartment just below the computer compartment Locate the ends to the computer hold down straps in this area Open the computer hold down straps so they are as big as possible but still connected Move these straps out of the way so the computer can be slide into this compartment without sliding it on top of the straps Look in the top of the computer compartment you will find a power strip Ensure all power cords are fully seated in this power strip as once the computer is in this is hard to check If not already done completely unpack the computer from its packaging Discard the power cord and modem cable that comes with the computer Locate the Product Key number on the top of the computer Write this number on the front of the Dell Computer User s Manual as it will be used later Place the computer product literature and software in the Unit s Storage Compartment Slide of the computer in from the rea
8. WINDOW SELECT COMM PORT C FOR TEST ATTACH APPROPRIATE LOOPBACK ADAPTER TO THE PORT UNDER TEST AT THE REAR CONNECTOR PANEL LOOPBACK ADAPTERS WILL ONLY FIT INTO APPROPRAITE CONNECTORS SELECT START VERIFY CORRECT LOOPBACK RESPONSE IN THE TEST STATUS WINDOW RX TX PASS RTS CTS PASS DTR DSR PASS IF THE TEST RESULTS ARE NOT AS EXPECTED PROCEED TO THE NEXT STEP OTHERWISE REPLACE THE CONNECTING CABLE REPLACE THE CONNECTING CABLE AND OR GAS CAP TESTER CHECK FOR 12 VOLTS ACROSS THE PINS OF J9 BAR CODE SCANNER POWER IF 12 VOLTS IS NOT PRESENT CHANGE THE CONTROLLER BOARD IF 12 VOLTS IS PRESENT AT THE CONTROLLER BOARD CHECK FOR THE 12 VOLTS AT THE BACK PANEL CONNECTORS COM C IF 12 VOLTS IS NOT PRESENT REPAIR OR REPLACE EFFECTED HARNESS OR TROUBLESHOOT REPLACE COMMUNCIATION BOX IF 12 VOLTS IS PRESENT REPLACE THE CONNECTING CABLE REPLACE THE CONNECTING CABLE AND OR GAS CAP TESTER COMPUTER TEST 1 Place the DELL Diagnostic CD in the CD ROM drive and reboot the computer During the initialization blue DELL screen press the F12 key to select the Boot Device Menu 3 NOTE SOME OF THE FOLLOWING STEPS HAVE TIMES IN SECONDS AT THE BEGINNING OF THE STEP THESE ARE TIMED STEPS AND A CHOICE MUST BE MADE BEFORE THE TIMER RUNS OUT OR THE DEFAULT WILL BE SELECTED 4 At the Boot Device Menu select the IDE CD ROM Device then press Enter N TEEEA135A0 4 25 2005 REV S Page 33 of 37 5 8 secon
9. in Enter the Station Number Obtained from the DMV press lt TAB gt Enter the Analyzer Serial Number press lt F10 gt The Analyzer Serial Number is entered as SZ followed by the actual unit serial number numeric digits Return to the Main Menu Select Station Menu Enter access code ST AT ON Select 2 Data File Lockout Status Refresh Contact the State to finish setting up Analyzer NC OBIS SOFTWARE SETUP COMPLETE TEEEA135A0 4 25 2005 REV S Page 22 of 37 4 Iftester has a previous version of OBIS software installed it must be removed Power Up the Analyzer and complete the following steps 5 P rior to uninstalling software a Data File Refresh should be performed to insure that no offline Inspections are stored on the tester gt o ur ID M i From the Main Menu select 3 Station Menu li Select 2 Data File Lockout Status Refresh and follow prompts Reboot to sign on screen and type Equiserv for the user name enter Equiserv for the password Note This is case sensitive Click on START in the lower left of the display Select SETTINGS and CONTROL PANEL Double click on ADD REMOVE PROGRAMS Scroll down to NC OBDII ANALYZER and select it Click on the REMOVE button and then the YES button to confirm From the CONTROL PANEL steps c and d select USERS AND PASSWORDS Select user PC and click REMOVE Select EQUISERV and click REMOVE Selec
10. the Monitor Attach the Video Data Cable coming out of the unit s top to the monitor Secure the extra monitor Video Cable with the straps below the unit s top INSTALLATION COMPLETE FOR DELL E771P AND DELL E772P COLOR MONITORS GOTO LINE 39 Locate the Monitor Mounting Bracket on the top of the unit Using a 2 5mm Allen Wrench remove the right side and left side Allen screw from the front bracket Remove the front bracket Repeat these steps for the rear bracket Locate the inner thumbscrews that are on the bottom of the front and rear brackets Unscrew these thumb screws all the way till they are removed Partially screw two thumbscrews only in the front Monitor Mounting Bracket in the inner holes from the topside of Monitor Mounting Bracket Place the balance of the six thumbscrews in a safe place in the storage cabinet Attach the rear Monitor Mounting Bracket using an Allen screw on the right side and left side using 2 5mm Allen Wrench Note There are no thumbscrews installed on the rear Monitor Mounting Bracket Place the monitor on the unit top and slide it into the cup in the rear bracket Install the front bracket using the Allen Screws Do not tighten the Allen Screws all the way Push the front bracket as far back as it will go to ensure that the monitor is snug between the two brackets Tighten both Allen Screws Locate the two inner thumbscrews Now screw the inner thumbscrews down to hold the monitor base to the unit A
11. 02 Scan Code 5 PROGRAMMING NUMERIC CODE 0 6 Set Scan Prefix Setup for Cntrl B STX 1002 Scan Code 6 PROGRAMMING NUMERIC CODE 0 7 Set Scan Prefix Setup for Cntrl B STX 1002 Scan Code 7 PROGRAMMING NUMERIC CODE 2 8 Set Scan Suffix Scan Code 8 SCAN SUFFIX TEEEA135A0 4 25 2005 REV S Page 16 of 37 9 Set Scan Suffix Setup for ETX 1003 Scan Code 9 PROGRAMMING NUMERIC CODE 1 10 Set Scan Suffix Setup for Cntrl C ETX 1003 Scan Code 10 PROGRAMMING NUMERIC CODE 0 11 Set Scan Suffix Setup for Cntrl C ETX 1003 Scan Code 11 PROGRAMMING NUMERIC CODE 0 12 Set Scan Suffix Setup for Cntrl C ETX 1003 Scan Code 12 PROGRAMMING NUMERIC CODE 3 13 Set Scan Parity Scan Code 13 EVEN PROGRAMMING CODE TEEEA135A0 4 25 2005 REV S Page 17 of 37 14 Set Scan 7 Bits Scan Code 14 SEVEN BIT PROGRAMMING CODE The following are the codes for programming the yellow 1D Bar Code Scanner P302FZY 1000 Set Scanner to Defaults Scan Code 1 Set All Defaults Set Scan Options Scan Code 2 Scan Options Set Scan lt Prefix gt lt Data gt lt Suffix gt Scan Code 3 lt Prefix gt lt Data gt lt Suffix gt Set Scan Enter Scan Code 4 TEEEA135A0 4 25 2005 REV S Page 18 of 37 Enter Set Scan Prefix Scan Code 5 Scan Prefix Set Scan Prefix Setup for Cntrl STX 1002 Sca
12. CK FOR 12 VOLTS ACROSS THE PINS OF J9 BAR CODE SCANNER POWER IF 12 VOLTS IS NOT PRESENT CHANGE THE CONTROLLER BOARD IF 12 VOLTS IS PRESENT AT THE CONTROLLER BOARD CHECK FOR THE 12 VOLTS AT THE BACK PANEL CONNECTORS COM H PINS 7 AND 25 BAR CODE SCANNER IF 12 VOLTS IS NOT PRESENT REPAIR OR REPLACE EFFECTED HARNESS OR TROUBLESHOOT REPLACE COMMUNCIATION BOX IF 12 VOLTS IS PRESENT REPLACE THE OBD II KEY AND CONNECTING CABLE VID COMMUNICATIONS MALFUCTIONS PROBLEM CAUSE SOLUTION NO NO DIALTONE BAD FROM THE MAIN MENU SELECT MANUFACTURER S COMMUNICATION TELEPHONE LINE BAD TECHNICIAN MENU 5 WITH VID TELEPHONE JACK INCORRECT ENTER DAILY SERVICE CODE AND PRESS F10 ANALYZER PHONE NUMBER SELECT DIAGNOSTIC MENU 2 INCORRECT VID PHONE _ FROM THE DIAGNOSTIC MENU SELECT NETWORK NUMBER OR BAD MODEM COMMUNICATION DIAGNOSTICS FROM THE NETWORK COMMUNICATION DIAGNOSTICS SELECT DIALTONE TEST YOU WILL HEAR A DIALTONE AND WILL RETURN BACK TO NETWORK COMMUNICATION DIAGNOSTICS MENU PAGE IF THERE IS NO DIALTONE CHECK PHONE LINE CONNECTION AND THE TELEPHONE WIRE REPLACE TELEPHONE WIRE AND OR TRY ANOTHER TELEPHONE LINE IF THE DIALTONE TEST IS OKAY VERIFY THE VID PHONE NUMBER AND ANALYZER PHONE NUMBER BY DOING THE FOLLOWING STEPS CLICK ON MANUFACTURERS TECHNICIAN MENU NUMBER 5 8 ENTER THE ACCESS CODE PRESS F10 TO CONTINUE 9 CLICK ON STATE FUNCTIONS NUMBER 3 10 CLICK ON UPDATE STATION
13. DWord Value 11 Verify the Gas Cap Tester by clicking on Gas Cap Tester and double clicking on CommPort You should see the following dialog as shown in Figure 3 Value name EemmPort Value data Base Hexadecimal Decimal Cancel Figure 3 Edit DWord Value 12 Verify OBDII Key by clicking on OBDII and double clicking on CommPort You should see the following dialog as shown in Figure 4 TEEEA135A0 4 25 2005 REV S Page 35 of 37 Figure 4 Edit DWord Value 13 Close Registry TEEEA135A0 4 25 2005 REV S Page 36 of 37 DIAGNOSTICS ESTS The Diagnostics Test is used for diagnosing and troubleshooting device related problems LOOPBACK TEST The Loopback Test is used for testing the COMM Ports on the Communication Box The test verifies that the COMM Ports are working correctly Tools needed set of 3 Loopback Adapters CPG 7 pin DE B DS 25 n SNAP ON PART EAE0030L10A SNAP ON PART EAE0027L05A SNAP ON PART EAE0027L04A 1 From the Main Menu select Manufacturer s Technician Menu 5 2 Enter daily Service Code and press lt F10 gt 3 Select Diagnostic Menu 5 4 From the Diagnostic Menu select Loopback Test 5 From the Serial Port drop down window select the desired port for test 6 Attach appropriate Loopback Adapter to the port under test at the rear Connector Panel Loopback adapters will only fit into appropriate connectors 7 Se
14. E PRODUCT LITERATURE DISKS AND CD s IN THE COMPARTMENT UNDER THE COMPUTER FROM THE WINDOWS 2000 MAIN MENU CLICK ON START THEN SHUTDOWN NEXT SELECT RESTART AND CLICK ON OK THIS WILL REBOOT THE COMPUTER WINDOWS 2000 SETUP COMPLETE TEEEA135A0 4 25 2005 REV S Page 14 of 37 BAR CODE SCANNER SETUP Once the analyzer has booted and Bar Code Scanner has power scan the following codes to program the respective yellow Bar Code Scanner For programming the and setting up the yellow Bar Code Scanner DS3408 SF20005 scan the 14 Bar Codes on page 14 in order For programming the and setting up the yellow 1D Bar Code Scanner P302FZY 1000 scan the 18 Bar Codes on page 17 in order Once all codes are scanned the Bar Code Scanner is ready for operation NOTE THE BAR CODE SCANNER WILL NOT WORK IF THE WRONG CODES ARE SCANNED IDENTIFY THE BAR CODE SCANNER AND CHOOSE THE CORRECT PROGRAMMING CODES DS3408 SF20005 P302FZY I000 The following are the codes for programming the yellow 2D Two Dimensional Bar Code Scanner DS3408 SF20005 1 Set Scanner to Defaults Scan Code 1 SET DEFAULT 2 Set Scan Prefix Data Suffix Scan Code 2 PREFIX DATA SUFFIX 3 Set Scan Prefix Scan Code 3 SCAN PREFIX TEEEA135A0 4 25 2005 REV S Page 15 of 37 4 Set Scan Prefix Setup for Cntrl B STX 1002 Scan Code 4 PROGRAMMING NUMERIC CODE 1 5 Set Scan Prefix Setup for Cntrl B STX 10
15. EQUIPMENT SERVICE ON SITE EEEA135A North Carolina OBIS Setup Instructions 1 of 37 Providing Factory Service For Automotive Service Equipment Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED EQUISERV PERSONNEL ONLY INSTALLATION OVERVIEW The following Installation Instructions will provide you with the procedures necessary to complete the final assembly of the OBIS These instructions will also provide you with a checkout procedure to ensure that the final assembly is completely functional PARTS amp ACCESSORIES LIST PART NUMBER DESCRIPTION QTY 1 12906A Screws 8 32x 38 16 3 03306A20 Printer OkiData B4250 1 6 03722A Modem Cable 1 6 04122A Cable Null Modem 1 6 04222A Cable OBDII Extension 1 8 01010A Paper 1 8 6419 Bushing 1 EAA0293E04B Unit Stand Assembly 1 EAA0293L14A Computer 1 EAE0032L52A OBDII Code Reader 1 EAS2052bE02A Bracket Scanner 1 EAS2052E07A Bracket Lead Hanger 7 70005100 Questionnaire 1 200081 02 Warranty Sheet 1 EEEH103A Bar Code Scanner 1 EESP304A Snap Link Package 1 MT2500 509A DB9 to DB25 Serial Port Adapter 1 TEEEA135A0 Installation Instructions 1 ZEEEA135A Operator s Manual North Carolina 1 REQUIRED TOOLS e 225 Key Obtained from Technical Support e 2 5mm Allen Wrench TEEEA135A0 4 25 2005 REV S Page 2 of 37 HARDWARE INSTALLATION INSTRUCTIONS 1 11 12 Carefully unpack all the items listed in the Parts amp Accessories
16. EW PRINTER CLICK ON THE CANCEL BUTTON AND CLOSE THE WINDOW THEN FOLLOW THE PROCEDURE BELOW 1 Select Start Settings Printers Double click on the ADD PRINTER icon The Welcome to the Add Printer Wizard will be displayed as shown in Figure1 Click on lt NEXT gt to continue Add Printer Wizard Welcome to the Add Printer Wizard This wizard helps you install a printer or make printer connection continue click Cancel Figure 1 Add Printer Wizard 2 The second page of the ADD PRINTER WIZARD will be displayed as shown in Figure 2 Click on LOCAL PRINTER Unclick the Automatically detect and install my Plug and Play printer Click on lt NEXT gt to continue Add Printer Wizard Local or Network Printer Is the printer attached to your computer If the printer is directly attached to your computer click Local printer If itis attached to another computer or directly to the network click Network printer C Local printer Iv Automatically detect and install my Plug and Play printer lt Back Cancel Figure 2 Local or Network Printer TEEEA135A0 4 25 2005 REV S Page 10 of 37 3 The third page of the ADD PRINTER WIZARD will be displayed as shown in Figure Click on Use the following port Next scroll down through the list of available ports until USBO001 is highlighted Then click on lt NEXT gt to continue Add Printer
17. NG STEPS EXIT FROM THE OBIS PROGRAM LOG IN AS EQUISERV RIGHT CLICK ON MY COMPUTER ICON ON WiNDOWS 2000 DESKTOP SELECT PROPERTIES FROM MENU BY LEFT CLICK OF THE MOUSE TEEEA135A0 4 25 2005 REV S Page 28 of 37 LEFT CLICK ON THE HARDWARE FOLDER TAB CLICK ON DEVICE MANAGER BUTTON EXPAND Ports COM amp LPT PROPERTIES BY CLICKING ON SIGN NEXT TO THE LABEL VERIFY WITH THE PICTURES BELOW FOR COMM PORT LABELS NOTE THAT THE VALUE FOR COM NUMBERS CAN BE DIFFERENT EXAMPLE COM L OBDII KEY COM7 COULD ALSO READ COM L OBDII KEY COM8 ENSURE THERE ARE NO YELLOW OR OR RED X CHECK MARKS ERRORS IN THE DEVICE MANAGER SEE FIGURE BELOW Device Manager Action IE gt Ea 24 03330821 m Computer ACPI Uniprocessor PC Disk drives C29 Maxtor 2B020H1 E M Sys DiskOnKey USB Device 5 Display adapters 2 SAMSUNG DYD ROM SD 616T Floppy disk controllers H E Floppy disk drives 1 52 IDE ATA ATAPI controllers 27 Dynamome ter COMS COM H Barcode Reader COM6 COM L OBDII Key Communications Port 1 ECP Printer Port LPT1 z SCSI and RAID controllers E Device Manager Action View gt 2 a D333Q821 Computer ACPI Uniprocessor Disk drives C3 Maxtor 2B020H1 M Sys DiskOnKey USB Device Display adapters Intel R Extreme Graph
18. ODE SCANNER OR CABLE AND THE CABLE REFER TO PAGE 14 FOR PART NUMBERS VERIFY THAT THE SCANNER CABLE HAS BLACK BREAKER ON IT IF NOT REPALCE THE CABLE WITH THE CORRECT ONE COMM PORTS NOT SET UP TO VERIFY THAT THE COMM PORTS ARE SET UP CORRECTLY IN SOFTWARE OR CORRECTLY IN SOFTWARE PERFORM THE FOLLOWING BAD COMMUNCIATIONS PORT STEPS H e EXIT FROM THE OBIS PROGRAM e LOGINAS EQUISERV e RIGHT CLICK ON MY COMPUTER ICON ON TEEEA135A0 4 25 2005 REV S Page 26 of 37 WINDOWS 2000 DESKTOP SELECT PROPERTIES FROM MENU BY LEFT CLICK OF THE MOUSE LEFT CLICK ON THE HARDWARE FOLDER TAB CLICK ON DEVICE MANAGER BUTTON EXPAND Ports COM amp LPT PROPERTIES BY CLICKING ON SIGN NEXT TO THE LABEL VERIFY WITH THE PICTURES BELOW FOR COMM PORT LABELS NOTE THAT THE VALUE FOR COM NUMBERS CAN BE DIFFERENT EXAMPLE COM H BARCODE READER COM6 COULD ALSO READ COM H BARCODE READER 8 ENSURE THERE ARE NO YELLOW OR OR RED X CHECK MARKS ERRORS IN THE DEVICE MANAGER SEE FIGURE BELOW Device Manager action we e gt e jm 4 03330821 J Maxtor 2B020H1 C29 M Sys DiskOnKey USB Devi 5 Display adapters 2 SAMSUNG DYD ROM SD 616T Floppy disk controllers H E Floppy disk drives 1 52 IDE ATA ATAPI controllers 41 85 Keyboards EF Intel R PRO 1000 MT Network Connection OBIS devi OBIS IR remote receiver E amp amp OBIS devi COM E Dynam
19. OR COM NUMBERS CAN BE DIFFERENT EXAMPLE COM C GAS CAP TESTER 4 COULD ALSO READ COM GAS CAP TESTER COM8 ENSURE THERE ARE NO YELLOW OR OR RED X CHECK MARKS ERRORS IN THE DEVICE MANAGER SEE FIGURE BELOW TEEEA135A0 4 25 2005 REV S Page 31 of 37 uj lt Device Manager Action View le gt gm m D333Q821 Computer ACPI Uniprocessor PC Disk drives amp Maxtor 2B020H1 M Svs DiskonKey USB Device 5 Display adapters Z SAMSUNG DVD ROM SD 616T Floppy disk controllers H E Floppy disk drives 9 52 IDE ATA ATAPI controllers odems Fe Monitors Network adapters Intel R PRO 1000 MT Network Connection COME Dy F COM H Barcode Reader COM6 27 COM L OBDII Key Communications Port 1 ECP Printer Port LPT1 SCSI and RAID controllers 2 Z Device Manager ction View B gt E Oh E 03330821 Computer ACPI Uniprocessor Disk drives amp Maxtor 2B020H1 5 5 DiskOnKey USB Device El Display adapters Intel R Extreme Graphics Controller 2 28 DVD CD ROM drives 2 SAMSUNG DVD ROM SD 616T 1 5 Floppy disk controllers 9 Floppy disk drives H IDE controllers H Keyboards fy Mice and other pointing devices Conexant HSF 92 56K Da
20. R JAM BY REMOVING THE BLINKING LAMMED PAPER TURN PAPER OVER IN TRAY NOTE ARROW ON PAPER PACKAGE INSTALL PAPER PRINT SIDE DOWN IN TRAY PAGES CURL EXCESSIVELY DUE TO HUMIDITY CAUSING PAPER JAM USE RECOMMENDED PAPER ADD PAPER AND ADJUST TRAY FOR PAPER SIZE OF 8 5X11 ADJUST TRAY FOR THE CORRECT PAPER SIZE OF 8 5X11 MAKE SURE THAT THE PAPER SIZE SETTING LOCKING MECHANISM IS NOT BROKEN OR DAMAGED AND DOES NOT MOVE AFTER IT IS SET TO THE CORRECT SIZE INSTALL TONER CARTRIDGE CORRECTLY REPLACE TONER CARTRIDGE LOW PAPER OR PAPER TRAY NOT SET TO CORRECT PAPER SIZE ERROR LIGHT BLINKING LOW TONER OR TONER CARTRIDGE NOT INSTALLED CORRECTLY PAPER TRAY NOT INSERTED PROPERLY OR FRONT COVER NOT CLOSED PROPERLY ERROR LIGHT BLINKING VERIFY THAT THE PAPER TRAY IS INSERTED ERROR LIGHT BLINKING CORRECTLY REMOVE THE PAPER TRAY AND REINSTALL IT CHECK THE FRONT COVER IF IT IS CLOSED ALL THE WAY OPEN THE FRONT COVER AND SANP IT SHUT ERROR LIGHT CAUSE UNKNOWN LOG ON AS PC BLINKING 1 DOUBLE CLICK ON THE PRINT MANANGER ICON RIGHT BOTTOM CORNER CHECK PRINTER STATUS CORRECT THE REPORTED PROBLEM IN PRINT MANAGER CLOSE ALL WINDOWS AND EXIT FROM PC LOG ON AS OBIS VERIFY THE PRINTER IS WORKING BLANK SHEETS IMAGE DRUM CARTRIDGE NOT E IMAGE DRUM CARTRIDGE PRINTED PROPERLY INSTALLED PRINTS BAD PRINTER SOFTWARE NOTSETUP e LoGINAS PC CHARACTERS AND CORRECTLY 1 CLICK ON START EXTRA PAGES 2 CLICK ON SETTINGS
21. TWARE LOG OUT AND LOGIN BACK AS OBIS FROM THE MAIN MENU SELECT SERVICE MENU 1 ENTER DAILY SERVICE CODE AND PRESS F10 SELECT DIAGNOSTIC MENU 2 SELECT LOOPBACK TEST FROM THE SERIAL PORT DROP DOWN WINDOW SELECT COMM PORT H FOR TEST ATTACH APPROPRIATE LOOPBACK ADAPTER TO THE PORT UNDER TEST AT THE REAR CONNECTOR PANEL LOOPBACK ADAPTERS WILL ONLY FIT INTO APPROPRAITE CONNECTORS SELECT START VERIFY CORRECT LOOPBACK RESPONSE IN THE TEST STATUS WINDOW RX TX PASS RTS CTS PASS DTR DSR PASS IF THE TEST RESULTS ARE NOT AS EXPECTED PROCEED TO THE NEXT STEP OTHERWISE REPLACE SCANNER CABLE AND OR SCANNER HEAD CHECK FOR 12 VOLTS ACROSS THE PINS OF J9 BAR CODE SCANNER POWER IF 12 VOLTS IS NOT PRESENT CHANGE THE CONTROLLER BOARD IF 12 VOLTS IS PRESENT AT THE CONTROLLER BOARD CHECK FOR THE 12 VOLTS AT THE BACK PANEL CONNECTORS COM H PINS 7 AND 25 BAR CODE SCANNER IF 12 VOLTS IS NOT PRESENT REPAIR OR REPLACE EFFECTED HARNESS OR TROUBLESHOOT REPLACE COMMUNCIATION BOX IF 12 VOLTS IS PRESENT REPLACE SCANNER CABLE AND OR SCANNER HEAD OBDII MALFUNCTIONS PROBLEM CAUSE SOLUTION No OBD Il WRONG OBD II KEY COMM VERIFY THE SNAP ON OBD KEY PART NUMBER THE COMMUNICATIONS PORTS NOT SET UP CORRECTLY CORRECT PART NUMBER IS EAE0032L52A IN SOFTWARE OR BAD TO VERIFY THAT THE COMM PORTS ARE SET UP COMMUNCIATIONS PORT L CORRECTLY IN SOFTWARE PERFORM THE FOLLOWI
22. ds From the Boot Menu press 2 to select Boot from the CD ROM 6 28 seconds Press 1 then Enter to select Run DELL Diagnostics f From the black and white Dell Diagnostics Menu press 1 to select Dell 32 bit Diagnostics for Resource CD for OptiPlex GX 150 or 260 or 270 8 After various modules load the following menu will be displayed MAIN MENU SERVICE TAG XXXXXX Express Test Extended Test Custom Test Symptom Test 9 Click on Express Test NOTE THE SCREEN MAY TURN BLACK FOR SHORT PERIODS DURING TESTING B THE TESTS WILL TAKE ABOUT 7 MINUTES TO COMPLETE 10 Upon completion of the tests the computer will indicate either failures or that no faults were found If one or more failures were detected the operator is prompted to select Ok to view the results 11 If a fault is detected or if no fault is detected but you still suspect a particular area you may select the option of Custom Test by clicking on the custom Test button from the Menu This will allow the user to test a individual device for more advanced testing 12 Press lt ESC gt key to exit or close the Diagnostic Menu by clicking on the box with an X in the upper right hand corner of the active window COMM PORT ASSIGNMENT VERIFICATION 1 Log into Windows as the Equiserv user 2 Inspect the current port settings by 3 Enter the system registry by clicking Start Run Type REGEDIT and press Enter Navigate to th
23. e following as shown in Figure 1 HKEY_LOCAL_MACHINE Software Snap on Diagnostics Emissions Analyzer Peripherals TEEEA135A0 4 25 2005 REV S Page 34 of 37 z Registry Editor Registry Edit View Favorites Help H Analog Devices Type Data H BYRP Software ab REG 52 value not set 9 03 Classes d REG DWORD 0x00002580 9600 2 Clients REG DWORD 0x00000006 6 Dell i REG DWORD 0 00000007 7 Dell Computer REG SZ EVEN Dell Computer Corporation REG DWORD 0x00000001 1 C Dell Computers J InstalledOptions 4 22 INTEL 4 21 Intervideo J Microsoft ODBC Okidata J Policies J Program Groups J Secure Snap on Diagnostics Emissions Analyzer J Applications 5 08 Peripherals X EParcode 5 A arcode 5canne J Gas Cap Tester J opp 1 Services J Voice Windows 3 1 Migration Status H A YAMAHA YAMAHA CORPORATION H SYSTEM J HKEY_USERS HKEY_CURRENT_CONFIG My Computer HKEY_LOCAL_MACHINE SOFTWARE Snap on Diagnostics Emissions Analyzer Peripherals Barcode Scanner Figure 1 Registry Editor 10 Verify barcode scanner by clicking on Barcode Scanner and double clicking on CommPort You should see the following dialog as shown in Figure 2 Value name EemmPort Value data Base 0 Hexadecimal Decimal Cancel Figure 2 Edit
24. ect Diagnostic Menu 5 vehicle end of the OBD II Reader to OBD II equipped vehicle Turn the ignition on From the Diagnostic Menu select OBDII Test 1 Allow a second or two for the data fields to fill in The data displayed will differ from vehicle to vehicle we are only concerned that data is appearing IF AFTER SEVERAL SECONDS THE SCREEN DISPLAYS ERROR OPENING OBD II THEN TEST ANOTHER VEHICLE OR PROCEED TO TROUBLESHOOTING OBDII TEST COMPLETE TEEEA135A0 4 25 2005 REV S
25. erv as the User ID and enter Equiserv as the password Note the User ID and Password are Case Sensitive 3 Follow the on screen prompts and the instructions in the Snap Link Manual starting on page 2 Do not change the destination folders instead let the software install with the defaults 4 After the installation is complete reboot to the OBIS Software Inspection Menu Locate the Snap Link Menu and select it When the Snap Link program appears enter the Shop Information Next enter the Registration number off the CD You must configure the COMM and Baud Rate Reference Page 7 of the Snap Link Book to set the settings as follows a SCANNER 1 li Baud Rate 4800 b VANTAGE l COM 1 c MICROVAT l COM 1 8 SNAP LINK connects to the Scanner through COMM on the rear of the OBIS using the Adapter MT2500 5094 provided 9 The MICROVAT will need an ACT IR220L and an Infrared Adapter SNAP LINK SETUP COMPLETE TEEEA135A0 4 25 2005 REV S Page 24 of 37 TROUBLESHOOTING This section addresses device issues and problems This section is developed to assist in troubleshooting external devices attached to the Analyzer PRINTER MALFUNCTIONS PROBLEM CAUSE SOLUTION VERY LIGHT PRINT TONER CARTRIDGE CHECK IF TONER IS INSTALLED CORRECTLY 2 CHECK IF THE SEALING TAPE ON THE TONER CARTRIDGE HAS BEEN REMOVED USE RECOMMENDED PAPER CLEAN LED ARRAY REPLACE TONER ERROR LIGHT PAPER JAM CLEAR THE PAPE
26. ics Controller 5 9 DVD CD ROM drives SAMSUNG DVD ROM SD 616T 1 5 Floppy disk controllers H E Floppy disk drives H IDE controllers 9 8 Keyboards 173 Mice and other pointing devices Conexant HSF 92 56K Data Fax PCI Modem Monitors Network adapters OBIS devices OBIS IR remote receiver OBIS devices gt OBIS IO module S Ports COM amp LPT 27 COM C Gas Cap Tester COMI 1 7 Dynamometer 10 7 COM H Barcode Reader COM9 27 COM L OBDII Key COMB Communications Port COM1 ECP Printer Port LPT1 K SCSI and RAID controllers lt Sound video and game controllers C29 Storage volumes System devices Universal Serial Bus controllers 2 IF THE COMM PORTS ASSIGNMENT ARE CORRECT PROCEED TO THE NEXT STEP OTHERWISE USING THE TEEEA135A0 4 25 2005 REV S Page 29 of 37 CORRECT RE IMAGE PROCEDURE AND SOFTWARE REINSTALL THE SOFTWARE LOG OUT AND LOGIN BACK AS OBIS FROM THE MAIN MENU SELECT SERVICE MENU 1 ENTER DAILY SERVICE CODE AND PRESS F10 SELECT DIAGNOSTIC MENU 2 CLICK ON OBD I COMMUNICATION TEST NUMBER 2 FOLLOW THE DIRECTIONS ON THE SCREEN ALLOW FOR THE DATA FIELDS TO FILL IN THE DATA DISPLAYED WILL DIFFER FROM VEHICLE TO VEHICLE WE ARE ONLY CONCERNED THAT DATA IS APPEARING IF IF THE TEST RESULTS ARE NOT AS EXPECTED PROCEED TO THE NEXT STEP CHE
27. k lt Next gt Follow the on screen instructions until it is completely loaded The Status Monitor can be accessed by going to Start Programs Okidata B4250 and maximizing the Status Monitor window For more information on how to use the status monitor refer to the OBIS Service Manual B4250 PRINTER INSTALLATION COMPLETE TEEEA135A0 4 25 2005 REV S Page 12 of 37 17 After Windows is done installing the drivers for the hardware it finds it should come up with a window telling you to restart your computer for the settings to take effect You should then click on Yes when it asks you Do you want to Restart your computer now 18 After Windows reboots back up click on the OK button to log on as the Administrator Do not use a password 19 Click on the START button in the bottom left hand corner of the screen 20 Next click on Programs then Accessories and then Command Prompt This will bring up a DOS Box on the screen 21 Inthe DOS Boxtypeconvert E fs NTFS asshownin Figure 6 22 The information as shown in Figure 6 will be displayed Type Y and press 23 You will now be C gt prompt Type E T andpress Command Prompt gt The type of the file system is FAT Determining disk space required for file system conversion Total disk space Free space on volume T762 Space required for conversion 2249 EKE Conve
28. k the My Computer icon Double click on the Drive D icon Double click on the OBDII folder Double click on the file setup exe Setup exe is the Icon with the computer Follow the prompts on the screen to install the software When prompted for the Serial use NC obis 2003 Reboot after installation 2 The Logon box will have OBIS as the user leave the password blank and click lt OK gt Enter OBIS as the user if it is not there 3 Setup customer After the following is complete the State will need to put the unit in Service a b C d From the Main Menu select 5 Service Menu Enter the current Widows Daily Access Code and press lt F10 gt to continue From the Service Menu Select 5 Date and Time Ensure date and time are set correct If not adjust time or date for accuracy Press lt OK gt From the Service Menu select State Audit Functions In the State Audit Functions Menu select Install New Data Disk From the Install New Data Disk screen select Initialize From the State Audit Functions select Network Initialization Comm Update Enter VID Phone Number 18662760864 press TAB Enter VID Username Obtained from DMV then press lt TAB gt Enter VID Password Obtained from DMV then press lt F10 gt From the State Audit Functions Menu select 4 Update Station and Inspector Information Enter using the drop down box the County the analyzer is located
29. le clamp at the bottom of the digital scanner and gently pull the clamp away from the bottom of the digital scanner Open the clamp and plug the interface cable modular connector into the cable interface port on the bottom of the digital scanner handle Gently tug the cable to ensure the connector is properly secured Close the clamp push it back into place and tighten the screws on the clamp to secure the cable into the bottom of the digital scanner To install the cable on the yellow 2D Bar Code Scanner P304PRO I000 or 1100 insert the cable and twist into place in the Scanner Head 51 Attach the other end of the cable to the rear panel connector port labeled COM 52 Locate the 6 Null Modem Cable 6 041224 in the kit 53 Attach one end of the Null Modem Cable to COM L Secure the cable using the screws in the connector 54 Locate the OBDII Reader EAE0032L52A in the kit Referring to figure 4 locate the label on the OBDII Reader that indicates which end connects towards the Vehicle and which end connects towards the Analyzer 55 Connect the end of the OBDII Reader labeled To Analyzer to the end of the cable installed in the step 53 56 Locate and attach the 15 OBDII Extension Cable 6 042224 to the other end of the OBDII Reader labeled To Vehicle Secure using the screws contained within the connector of the vehicle Figure 3 Scanner Bracket TEEEA135A0 4 25 2005 REV S Page 5 of 37 TO VEHICLE
30. lect Start Verify correct Loopback response in the Test Status window with the table below COM Port TXIRX RTS CTS DTR DSR 0 Status s Status nenne E Pes Pass Pass Orr Pse Pes Table 2 6 Expected Loopback Test Results NOTE IF LOOPBACK RESULTS DO NOT MATCH EXPECTED RESULTS IN THE ABOVE TABLE PROCEED TO TROUBLESHOOTING LOOPBACK TEST COMPLETE SWITCH TEST The Switch Test is used to test the Fuel Cap Tester Power Tools needed one Loopback Adapter 7 pin SNAP ON PART EAE0030L10A From the Main Menu select Manufacturer s Technician Menu 5 Enter daily Service Code and press lt F10 gt Select Diagnostic Menu 5 From the Diagnostic Menu select Switch Test Attach the 7 Pin CPC Loopback Adapter to the Fuel Cap Tester Connector C Select the Power 1 button power to port C Reselecting this button should toggle the LED on the Loopback Adapter ON and OFF CUI Fu a lS cs NOTE IF LOOPBACK RESULTS DO NOT MATCH EXPECTED RESULTS PROCEED TO TROUBLESHOOTINC SWITCH TEST COMPLETE TEEEA135A0 4 25 2005 REV S Page 37 of 37 DIALTONE TEST The Dialtone test confirms that the computer is connected to a good phone line via a good telephone cable C Ty From the Main Menu select Manufacturer s Technician Menu 5 Enter daily Service Code and press lt F10 gt Select Diagnostic Menu 5 From the Diagnostic Menu select Network C
31. n Code 6 Set Scan Prefix Setup for Cntrl B STX me Scan Code 7 0 Set Scan Prefix Setup for Cntrl B STX 1002 Scan Code 8 0 TEEEA135A0 4 25 2005 REV S Page 19 of 37 Set Scan Prefix Setup for Cntrl STX 1002 Scan Code 9 1 Set Scan Sufix Scan Code 10 Scan Suffix Set Scan Sufix Setup for Cntrl ETX 1003 Scan Code 11 oet Scan Sufix Setup for Cntrl C ETX 1003 Scan Code 12 0 Set Scan Sufix Setup for Cntrl ETX 1003 Scan Code 13 0 TEEEA135A0 4 25 2005 REV S Page 20 of 37 Set Scan Sufix Setup for Cntrl C ETX 1003 Scan Code 14 3 Set Scan Parity Even Scan Code 15 i Even Set Scan 7 Bits Scan Code 16 7 Bit Set Scan Enable No Read Scan Code 17 Enable No Read Set Scan Baud Rate 9600 Scan Code 18 Baud Rate 9500 BAR CODE SCANNER SETUP COMPLETE TEEEA135A0 4 25 2005 REV S Page 21 of 37 SETTING UP NC OBIS SOFTWARE NOTE IF THE TESTER HAS A PREVIOUS VERSION OF OBIS SOFTWARE INSTALLED CONTINUE TO STEP 4 ON PAGE 19 1 Ifthe tester does NOT have a previous version of OBIS installed initial setup Power Up the Analyzer and complete the following steps If it does skip to step 4 on page 14 a Log as Administrator Place OBIS CD ROM in drive From the desktop double clic
32. ometer COMS COM H Barcode Reader COM6 27 COM L OBDII Key 7 Communications Port COM1 ECP Printer Port LPT1 lt SCSI and RAID controllers lt 5 Sound video and game controllers E Device Manager Action a E D333Q821 Computer ACPI Uniprocessor Disk drives Maxtor 2B020H1 M Sys DiskOnKey USB Device Display adapters Intel R Extreme Graphics Controller 2 8 DVD CD ROM drives 2 SAMSUNG DVD ROM SD 616T 1 5 Floppy disk controllers amp 9 Floppy disk drives 5 IDE ATA ATAPI controllers Gg Keyboards A Mice and other pointing devices Conexant HSF v92 56K Data Fax PCI Modem Monitors 88 Network adapters OBIS devices amp OBIS IR remote receiver 15 devices gt OBIS IO module S Ports COM amp LPT 27 COM C Gas Cap Tester COMI 1 27 Dynamometer 10 7 COM H Barcode Reader COM9 27 COM L OBDII Key COMB Communications Port 1 ECP Printer Port LPT1 KS SCSI and RAID controllers lt Sound video and game controllers H E Storage volumes BN System devices 6 Universal Serial Bus controllers TEEEA135A0 4 25 2005 REV S Page 27 of 37 1 IF THE COMM PORTS ASSIGNMENT ARE CORRECT PROCEED TO THE NEXT STEP OTHERWISE USING THE CORRECT RE IMAGE PROCEDURE AND SOFTWARE REINSTALL THE SOF
33. ommunication Diagnostics From the Network Communication Diagnostics select Dialtone Check 2 You will hear a Dialtone and will return back to Network Communication Diagnostics menu page if there is no Dialtone check phone line connection and the telephone wire Replace telephone wire and or try another telephone line DIALTONE TEST COMPLETE MODEM TEST The Modem test confirms that the modem inside the Computer is functional NOTE BEFORE DOING THE MODEM TEST A DIALTONE TEST NEEDS TO BE PERFORMED 1 QUE M me S From the Main Menu select Manufacturer s Technician Menu 5 Enter daily Service Code and press lt F10 gt Select Diagnostic Menu 5 From the Diagnostic Menu select Network Communication Diagnostics From the Network Communication Diagnostics select Modem Diagnostics 1 Verify that the Computer is connected using a telephone line to a telephone jack A successful modem test will return back to Network Communication Diagnostics menu page if the modem is bad or not working communication error will be reported Replace Computer MODEM TEST COMPLETE OBDII TEST The OBDII test is used for verifying the Communication between the Analyzer and Vehicle NOTE 1 2 9 4 With the OBD II Reader connected its cable and the cable connected to Port L connect the x From the Main Menu select Manufacturer s Technician Menu 5 Enter daily Service Code and press lt F10 gt Sel
34. r of the analyzer such that the rear of the computer is facing the rear of the unit While sliding the computer in place the front and rear straps over the top of the computer Once the computer is the way in place the foam block on top of the computer with the thicker side of the block on the left if viewed from the rear about 4 from the front Once the computer is in tighten the straps To tighten the straps pull on the loose end of the strap below the computer compartment These straps do not have to be extremely tight snug is enough Referring to Figure 1 and 2 attach the following cables to the computer e Power Connector Video Connector 2 USB Connectors e Keyboard Connector Mouse Connector 9pin DB Connector to Com 1 Figure 2 Video Hookup Figure 1 Computer Hookups 13 Run 8 inches of the phone cord 6 03722A through the side of computer compartment TEEEA135A0 4 25 2005 REV S 14 15 16 17 18 19 20 21 NOTE 22 23 24 25 26 27 28 29 NOTE 30 31 32 33 34 35 36 Page 3 of 37 Place the Heyco Bushing 8 6419 on the cord at this point Using Heyco Pliers push the bushing into the hole Plug the end of the phone cord now in the computer compartment into the jack on the rear of the computer the modem card with a picture of the connector on it Not the jack with the picture of the telephone Fully extend the Keyboard Drawer by lifting
35. rting File system Conversion complete CoN Figure 5 NTFS Disk On Key 24 Right Click on the Desktop 25 Click on Properties 26 Click on the Screen Saver tab 2 Click on the Power button 28 From the Power Schemes windows select Always On 29 Click on Apply button 30 Close the Display Properties window by clicking on X located in the top right corner of the Display Properties window TEEEA135A0 4 25 2005 REV S Page 13 of 37 CHECKING THE INSTALLATION Right click on My Computer icon on Windows 2000 Desktop Click on Properties Click on the Hardware folder tab Click on Device Manager button Click on the sign next to Ports Compare your device settings with the figures 8 or 9 um De PORTS should be identical NOTE MANAGER SEE FIGURES 8 9 BELOW Device Manager Note that the COMM values might no be the same as you see in the figures 8 or 9 but the labels for the COMM ENSURE THERE ARE NO YELLOW oR OR RED X CHECK MARKS ERRORS IN THE DEVICE Action View m H Floppy disk controllers 9 Floppy disk drives 1 52 IDE controllers S Keyboards Mice and other pointing devices 3 Modems Monitors OBIS devices OBIS devices Other devices b Ports COM amp LPT S COM C Gas Cap Tester 4 7 COM E Dynamometer 5
36. s displayed remove the OBIS Re lmage Utility Floppy Disk from the flo drive and remove the OBIS Re lmage Utility CD from the DVD ROM drive TEEEA135A0 4 25 2005 REV S Page 8 of 37 14 Select Reboot or Reset the computer to reboot up to Windows 2000 15 Next click on the OK button to log on as the Administrator Do not use a password 16 If for some reason Windows Plug and Play does not automatically go through on its own you may have to select OK or Next and then select the CD ROM device or the path of CADRIVERSYOBIS DRIVERS to tell it the location of the drivers it is looking for You have to repeat this process for each driver Refer to the table below for list of drivers Devices Where to find the Driver Okidata B4200 Printer Drivers Okidata Printer Driver CD included with the Printer Rocket Port Rocket Port USB to Serial Hub Drivers to Serial Hub Drivers CADrivers OBIS Drivers Drivers OBIS Drivers Moxa 1240 USB to Serial Hub Drivers kaa sss ss Drivers OBIS Drivers or Moxa USB Serial Hub Driver Part 3 39226AUSD1 IR Port Drivers C Drivers OBIS Drivers NOTE IF YOUR UNIT HAS A B4250 PRINTER INSTALLED FOLLOW THE INSTRUCTIONS ON THE FOLLOWING PAGES IF NOT SKIP TO STEP 17 ON PAGE 12 TEEEA135A0 4 25 2005 REV S Page 9 of 37 Setting up the OKI B4250 PRINTER on OBIS Installing the B4250 Printer Driver NOTE IF WINDOWS PLUG AND PLAY FINDS THE N
37. s setup to CD ROM Hard Drive and Diskette If it is not highlight each device and press the or key to move it to the correct position Press when completed 7 back at the BIOS Main Menu use the cursor to highlight System Security and press 8 Cursor down until Chassis Intrusion is highlighted Press to set Chassis Intrusion to Enabled 9 Highlight Setup Password and press NOTE IN THE NEXT STEP ENSURE THE PROPER PASSWORD IS TYPED IN IF THE PASSWORD IS DIFFERENT AND IS NOT KNOWN THEN THE COMPUTER WILL NEED TO BE REPLACED 10 When prompted to enter a Setup Password type R Z T F 1 and press 11 To confirm the Setup Password once again type R Z T F 1 and press 12 Once back at the BIOS Main Menu highlight Power Management then AC Power Recovery and press set the AC Power Recovery to On 13 Press lt ESC gt to exit the BIOS When prompted highlight Save Changes and Exit and press 14 The analyzer will now reboot 15 Again attempt to access the computer by pressing F2 Ensure that the computer now requires you to enter the password to access the BIOS and ensure that RZTF1 works NOTE ALSO ENSURE THAT THE COMPUTER DOES NOT REQUIRE A PASSWORD TO ENTER WINDOWS IF DOES THE WRONG SECURITY PASSWORD HAS BEEN SET RETURN TO THE BIOS AND DISABLE THE SYSTEM PASSWORD BY PRESSING ENTER FOR THE PASSWORD AND SET THE SETUP PASSWORD AS INDICATED ABOVE TEEEA135A0 4 25 2005 REV S Page 7 of 37
38. t 8 Atthe Name your Printer Prompt click lt NEXT gt 9 Highlight Do Not Share this Printer and click lt NEXT gt 10 When prompted Do You Want To Print a Test Page click YES and then lt NEXT gt 11 Next click on FINISH and then lt OK gt if the page printed correctly 12 Remove the OKIDATA B4250 Installation Software CD ROM disks from the DVD ROM Drive and places it in the Unit s Storage Compartment TEEEA135A0 4 25 2005 REV S Page 11 of 37 INSTALLING THE B4250 STATUS MONITOR 1 2 3 4 10 11 12 13 First you must uninstall the B4200 status monitor by going to Start Settings Control Panel Double click on Add Remove Programs Scroll down the list of software until you get to the OKI B4200 program Click on Change Remove It will ask you if you want to confirm file deletion Click on Yes and it will uninstall Click on OK when completed Close the Add Remove Programs window by clicking on the X in the upper right hand corner of the window Next go to Start Run Browse Browse to your DVD ROM drive where the CD is inserted and double click on Install exe Click lt OK gt The License Agreement appears Click lt Next gt if you accept the terms Select your Language Then select the Printers Model number B4250 from the list and click on Continue The software Installation screen should appear Click on Status Monitor Install Shield Wizard appears Clic
39. t OBIS and click REMOVE The click OK to finish user removals From desktop double click My Computer Double click on Drive Highlight NCASDAT A by single clicking on the NCASDATA folder Delete this folder by pressing the Delete key Highlight NCWDATA by single clicking on the NCWDATA folder Delete this folder by pressing the Delete key Double click on documents and settings Highlight PC by single clicking on the PC folder Delete this folder by pressing the Delete key Highlight OBIS by single clicking on the OBIS folder Delete this folder by pressing the Delete key Highlight Equiserv by single clicking on the Equiserv folder Delete this folder by pressing the Delete key Return to the root C directory by pressing the back key Double click on the Program files If Windows doesn t display the files in this folder click on show files Highlight Snap on Diagnostics by single clicking on the Snap on Diagnostics folder Delete this folder by pressing the Delete key All previous versions and associated files should now be removed After any old version of OBIS is removed go back to instruction 1 and install the software OLD SOFTWARE REMOVAL COMPLETE PROCEED TO STEP 1 ON PAGE 21 FOR SOFTWARE INSTALL TEEEA135A0 4 25 2005 REV S Page 23 of 37 SNAP LINK SOFTWARE INSTALLATION 1 Reboot the analyzer 2 From the Windows Login screen log in as Equis
40. ta Fax PCI Modem Monitors Network adapters OBIS devices OBIS IR remote receiver OBIS devices gt OBIS IO module S Ports COM amp LPT 27 COM C Gas Cap Tester COMI 1 27 COM E Dynamometer 10 aF COM H Barcode Reader 27 COM L OBDII Key COMB F Communications Port COM1 7 ECP Printer Port LPT1 H SCSI and RAID controllers E K Sound video and game controllers 9 Storage volumes N System devices 6 Universal Serial Bus controllers e F THE COMM PORTS ASSIGNMENT ARE CORRECT PROCEED TO THE NEXT STEP OTHERWISE USING THE CORRECT RE IMAGE PROCEDURE AND SOFTWARE REINSTALL THE SOFTWARE LOG OUT AND LOGIN BACK AS OBIS FROM THE MAIN MENU SELECT MANUFACTURER S TECHNICIAN MENU 5 ENTER DAILY SERVICE CODE AND PRESS F10 SELECT DIAGNOSTIC MENU 2 FROM THE DIAGNOSTIC MENU SELECT SWITCH TEST ATTACH THE 7 PIN CPC LOOPBACK ADAPTER TO THE FUEL CAP TESTER CONNECTOR C SELECT THE POWER 1 BUTTON POWER TO PORT C RESELECTING THIS BUTTON SHOULD TOGGLE THE LED ON THE LOOPBACK ADAPTER ON AND OFF IF THE TEST TEEEA135A0 4 25 2005 REV S Page 32 of 37 FAILS REPLACE THE CONNECTING CABLE AND OR GAS CAP TESTER OTHERWISWE CONTINUE TO THE NEXT STEP FROM THE MAIN MENU SELECT SERVICE MENU 1 ENTER DAILY SERVICE CODE AND PRESS F10 SELECT DIAGNOSTIC MENU 2 SELECT LOOPBACK TEST FROM THE SERIAL PORT DROP DOWN
41. ttach the AC Power Cable coming out of the unit s top to the Monitor TEEEA135A0 4 25 2005 REV S Page 4 of 37 37 Attach the Video Data Cable coming out of the unit s top to the monitor 38 Secure the extra monitor Video Cable with the straps below the unit s top NOTE INSTALLATION COMPLETE FOR DELL E773S COLOR MONITOR GOTO LINE 39 39 Unpack the Printer 3 03306A20 if it is not already done 40 Referring to the Printer Literature install the printer s toner cartridge 41 Place the Printer s Product Literature and in the Unit s Storage Compartment Leave the CD out as it will be needed to load the printer drivers later 42 Place the Printer on the top of the unit next to the monitor 43 Attach the Printer s Power Cable coming out of the unit s top to the Printer 44 Attach the Printers USB Data Cable coming out of the unit s top to the Printer 45 Ensure the Printer s Power Switch is the on 1 position 46 Load 100 sheets of paper 8 010104 into the printer 47 Referring to Figure 3 mount the Bar Code Scanner Bracket EAS2052E02A using two screws 1 129064 48 Unpack the Bar Code Scanner 102 if it is not already done 49 Throw away all literature that comes with the Bar Code Scanner 50 Attach one end of the Bar Code Scanner Cable to the Bar Code Scanner Head To install the interface cable for the 2D Two Dimensional Bar Code Scanner DS3408 SF20005 loosen the two screws on the cab
42. up on the Drawer Latches The latches are the cone shaped silver knobs on the front top corners of the unit Place the Keyboard and Mouse in the Keyboard Drawer Attach the Keyboard and Mouse PS2 Connectors to their respective connectors on the rear of the Keyboard Drawer Unpack the Monitor if it is not already done Discard the power cord with the monitor and place the monitor product literature in the Unit s Storage Compartment Install the monitor base according to the literature with the monitor FOR INSTALLING DELL E771P AND DELL E772P COLOR MONITOR GOTO LINE 22 FOR INSTALLING DELL E773S COLOR MONITOR GOT TO LINE 30 Locate the Monitor Mounting Bracket on the top of the unit Locate the four inner thumbscrews that are on the bottom of the bracket Screw these thumb screws all the way up so all of the threads of the screw are poking through the top of the sheet metal Using a 2 5mm Allen Wrench remove the right side right Allen screw from the front bracket and loosen the left side Allen Screw Swing open the front bracket Place the monitor on the unit top and slide it into the cup in the rear bracket Slide the front bracket closed and replace the Allen Screw Push the front bracket as far back as it will go to ensure that the monitor is snug between the two brackets Tighten both Allen Screws Now screw the inner thumbscrews down to hold the monitor base to the unit Attach the AC Power Cable coming out of the unit s top to
43. wizard Selectthe Printer Port Computers cornmunicate with printers through ports Selectthe port you want your printer to use Ifthe portis notlisted you can create new port Use the following port LPT Printer Port LPT3 Printer Port COM T Serial Port 2 Serial Port COM3 Serial Port Note Most computers use the LPT1 portto communicate with a local printer C Create a new port Type lt Back Cancel Figure 3 Printer Port 4 The fourth page of the ADD PRINTER WIZARD will be displayed as shown in Figure 4 Click on HAVE DISK gt This will bring up the INSTALL FROM DISK splash screen Add Printer Wizard E Add Printer wizard manutacturer and model determine which printer to use m Selectthe manufacturer and model of your printer If your printer came with an installation disk E click Have Disk Hssaur printer is not listed consultyour printer documentation for a compatible pner Mianufacturers Printers amp AGFAAccuSet ve 3 Figure 4 Printer Manufacturer 5 Place the OKIDATA B4250 Installation Software CD ROM disk in the DVD ROM drive of the computer Wait 10 seconds for the Drive to read the disk 6 Inthe Copy manufacturer s file from field Go to Browse and click D Drivers B4250 English Win2k_xp directory and select the B42503e Inf file and click on Open 7 Inthe INSTALL FROM DISK splash screen click on lt OK g
Download Pdf Manuals
Related Search
Related Contents
Active Cabinets XSA 110 – XSA 112 – XSA 115 Manual - Prodance Kempoweld 3200, 3200W User Manual Craftsman 536.772301 Edger User Manual Manual PNT800L - Emhart Media Library Extron electronic Extron Electronics Switch RCP 2000 User's Manual コファーノ取扱説明書 [PDF:6.1MB] NOTICE D`UTILISATION INS RAM-90NP5A (SP) Copyright © All rights reserved.