Home

am2000 air user manual am2000 mover user manual

image

Contents

1. drying applications Each model incorporates a double inlet centrifugal type fan design to provide the high static pressure and airflow required to dry water damaged facilities and equipment The EIPL Air Mover series was designed to provide you the best performance and serviceability e 25 ft Power Cord with cord grip IMPORTANT The wires in this mains lead are coloured in accordance with the following code e Internal thermal Circuit Breaker e Aerodynamic Rotationally Moulded Polythene Housing e Stack ability in the Vertical 90 Plane during both Storage and Operation e Moulded Cord wrap Facility OPERATING PROCEDURES Connect the power cord into a grounded electrical outlet and turn the power switch to the ON position If you have no power or hear any loud or abnormal noises and consult your supplier Your EIPL Air Mover is designed to operate in 4 positions to allow drying of floors walls and ceilings Your EIPL Air Mover comes with internal circuit protection for your safety When working around a wet environment we also recommend always plugging the unit into a ground fault interrupter to assure the best protection For the drying of water damaged facilities we recommend using an EIPL dehumidifier along with your air mover to provide you with more efficient drying Your air mover is designed to induce evaporation or water contained within flooded surfaces or materials Yet without a mechanism for
2. removing the moisture from the air drying will not occur It is recommended that the dehumidifier outlet is close to the air mover intake This allows for dry air to be distributed by the air mover ELECTRICAL CONNECTION If the appliance is fitted with a plug for which your socket is unsuitable then it should be cut off and an appropriate plug fitted e High Efficient 1 2 HP Motor Green Earth e Three Speed Fan Design White Neutral e 4 operating Positions 0 12 45 amp Black Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your own plug proceed as follows The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or by the Earth The wire which is coloured White must be connected to the terminal in the plug which is marked with the letter N The wire which is coloured Black must be connected to the terminal which is marked with the letter L You must dispose of the non rewireable plug once it has been removed from the flexible cord It is dangerous to attempt to insert the plug into any electrical socket elsewhere in the house If the flexible cord becomes damaged it must be replaced by an identical cord This appliance complies with the EMC Directive 2004 108 EC IF YOUR AIRMOVER FAILS TO OPERATE 1 Check that the plug is fully pushed into the socket an
3. UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd Ebac Industrial Products Inc Ebac Industrial Products Ltd St Helens Trading Estate 700 Thimble Shoals Blvd Gartenfelder Str 29 37 Bishop Auckland Suite 109 Newport News Geb ude 35 County Durham Virginia 23606 2575 D 13599 Berlin DL14 9AD USA Germany Tel 44 0 1388 664400 Tel 01 757 873 6800 Tel 49 3043 557241 Fax 44 0 1388 662590 Fax 01 757 873 3632 Fax 49 3043 557240 www eipl co uk www ebacusa com www eip ltd de sales eipl co uk sales ebacusa com sales eip ltd de AM2000 AIR MOVER USER MANUAL READ AND SAVE THESE INSTRUCTIONS Drawing No Issue Date TPC403 4 06 06 14 Electric shock hazard rotating fan hot surface hazard Unplug unit before opening covers for cleaning or servicing This machine should be serviced by qualified Ebac personnel or other persons having technical competence servicing refrigeration equipment following the instructions in the Ebac service manual Ebac service manuals and spares lists are available upon request by contacting your local Ebac distributor Never operate the unit in a bathroom or swimming pool area Do not use the machine if the power cord or case is damaged Do not poke objects into and of the grilles on the machine Do not cover or obstruct the air inlet or outlet This machine has been manufactured in the United Kingdom This appliance can be used b
4. d is switched on 2 Check with some other electrical device that the wall socket is live If it is not contact a qualified electrician 3 Check the circuit breaker on the control panel and reset as required Should none of the above remedies work then disconnect from the mains Contact your supplier DO NOT attempt to repair the unit or unscrew the outer casing
5. y children from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Not Suitable for use with solid state speed controls Ne convient pas a des r gulateurs de vitesse a semi conducteurs WARNING THIS APPLIANCE MUST BE EARTHED TECHNICAL SPECIFICATIONS AM2000 Height Width Depth Weight 115V 60Hz 1 PH 21 20 19 34lbs UNPACKING Remove the top insert and your EIPL Air Mover from its packing carton visually inspect for any signs of transit damage If there are any signs of damage do not operate your unit Call your supplier immediately for advice Do not discard the packing for it will be useful for transporting your unit in the future TRANSPORTATION A cord wrapping facility has been moulded into the plastic fan housing The power cord should be wrapped around this facility during transit Do not drop or abuse your Air Mover during Horsepower 2 Max running current 5A Fan Speeds 3 transit for risk of damage to both the motor and housing INTRODUCTION EIPL Air Movers are high performance high efficiency fan systems designed to optimize air movement and minimize operating costs for

Download Pdf Manuals

image

Related Search

Related Contents

Nokia BH-606 Headphones User Manual  Pando P-892  Philips SPC 900NC PC Camera  Sem título-1 - Eco Aquecedores  GSアンテナ 2 Beams cs DーGーTAL pdpub。  Operating Instructions  Digi-Cam Action Camcorder – what does it look like  caderno de especificações - Prefeitura Municipal de São Manuel  Montage- und Bedienungsanleitung für Saunasteuergeräte    