Home
RM4000 Data Sheet
Contents
1. Description 1 1 each 386 7420 xx PLATE MOUNTING RACKMOUNT LEFT 2 1 each 386 7421 xx PLATE MOUNTING RACKMOUNT RIGHT 3 2 each 367 0525 xx HANDLE CARRYING 0 375 AL POWDER COAT PEKING GRAY 4 1 each 386 7466 xx PLATE SUPPORT RACKMOUNT TOP 5 1 each 386 7467 XX PLATE SUPPORT RACKMOUNT BACK 6 12each 211 0722 xx SCREW MACHINE 6 32 X 0 250 PNH 410 SS PASSIVATED T 15 TORX DR 7 4 each 212 0577 xx SCREW MACHINE 10 32 X 0 625 TRH 410 SS PASSIVATE POZ 8 4 each 212 0681 xx SCREW MACHINE 10 32 X 0 25 PNH 410 SS PASSIVATE T25 TORX 9 4 each 361 1832 xx SPACER RECTANGULAR WASHER 888 X 1 000 X 225 10 1 each 351 1095 xx SLIDE ASSY PAIR W STD HARDWARE KIT AND REAR BRACKET 11 4 each 211 0734 xx SCREW MACHINE 6 32 X 0 250 FLH100 410 SS PASSIVATED T 10 TORX 1 each 071 2134 01 TECH MANUAL INSTRUCTIONS RACK MOUNT KIT TEKTRONIX 4000 SERIES RM4000 Rackmount Kit 3 Kit Description Figure 1 Rackmount kit parts part appearance may vary RM4000 Rackmount Kit Kit Description Warranted Characteristics RM4000 Rackmount Kit When the instrument is installed according to the instructions in this document the rackmounted instrument meets all warranted characteristics listed in the instrument specification except for those listed in Environmental Requirements on page 6 Instruments mounted using methods other than those described in these instruction
2. Pan head 10 32 Pan head screws 4 D E C gt screws 4 screws 4 Use two flat head screws if the cabinet rails have countersunk mounting holes otherwise use two S pan head screws Mounting Method B Mounting Method A Figure 12 Installation of slide out track assemblies in rack top view 18 RM4000 Rackmount Kit Installation Instructions 3 Mount the instrument in the rack WARNING To prevent the instrument from tipping or dropping onto the install ers two or more people should install this instrument into the rack cabinet After completing the installation procedure the installers should verify that the instrument and rack cabinet will not tip forward while the instrument is in the extended position a Install the instrument Working from the front of the rack slide the inner track of each slide out track assembly until it extends out the front of the rack Continue to slide them out until they lock Insert the left and right tracks that extend from the rear of the instrument into the ends of the tracks just extended Make sure the tracks mounted on the instrument slip inside the inner tracks extended earlier Slide the instrument backwards until it stops Push to release the button latches located on the outside of each track and continue to slide the instrument all the way into the cabinet b Level the rackmounted instrument RM4000 Rackmount Kit Tighten the four screws that we
3. holes that mount the rear bracket so that the flange to flange distance matches the distance between the front rail and rear rail measured in step a c Using a screwdriver with a number two PoziDriv tip secure the rear bracket to the right slide out track using two screws 10 32 and a bar nut as illustrated Leave the screws loose so that the overall length of the slide out track assembly can be adjusted when installing it in the rack d Repeat steps b and c to assemble the left slide out track assembly 15 Installation Instructions 2 Mount the slide out track assemblies using the slide drawer hardware listed in the kit parts list Figure 1 10 a Select the mounting position in rack Select two 0 5 inch spaced holes in the front rail Verify that the 4 36 inch and 10 500 inch clearances exist relative to those mounting holes See Figure 11 on page 17 Rear flange mounts to rear rail of rack Flange to Flange 514 4 mm 20 25 in minimum to 673 1 mm 26 50 in maximum Rear bracket Right slide out track assembly Outer track Round cut out Front flange mounts to front rail of rack a Inner track Left slide out track assembly Figure 10 Assembly of slide out track assemblies 16 RM4000 Rackmount Kit Installation Instructions A Securing holes 76 2 mm tapped for 3 000 in DS 2 10 32 screws LE 221 488 mm 12 7 mm 0 50 in 8 720 in for correct position of s
4. mounting gt ra J plate k T Oe Figure 5 Installing the left and right mounting plates 2 Install the two handles using four 10 32 x 0 25 inch pan head T 25 TORX drive screws tightened to 16 in Ib Handles should curve towards the sides of the instrument See Figure 6 3 Fasten the back support plate to the left and right mounting plates with four 6 32 x 0 250 inch pan head T 15 TORX drive screws lining up the dimples RM4000 Rackmount Kit 11 Installation Instructions in the back support plate with the slots in the mounting plates Tighten screws to 8 in lb See Figure 6 NOTE The back support plate and top support plate have holes to facilitate mounting optional accessories For example Figure 6 shows the TEK USB 488 GPIB to USB Adapter mounted to the back support with screws You can also use nylon straps to mount accessories 4 Install the top support plate on the left and right mounting plates using four 6 32 x 0 250 inch flathead T 10 TORX drive screws tightened to 8 in Ib See Figure 6 Top support plate Flathead gt o screws 4 Optional accessory Handle 2 Back support plate R Screws 4 Fe se R S K Le ioe LT Screws 4 K Figure 6 Installing the handles top and back support 12 RM4000 Rackmount Kit Installation Instructions 5 Remove the front section of each of the two tr
5. Instructions Tektronix 7 RM4000 Tektronix 4000 Series Rackmount Kit 071 2134 01 Warning The servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless you are qualified to do so Refer to all safety summaries prior to performing service www tektronix com Te NT 071213401 Copyright Tektronix All rights reserved Licensed software products are owned by Tektronix or its subsidiaries or suppliers and are protected by national copyright laws and international treaty provisions Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc Contacting Tektronix Tektronix Inc 14200 SW Karl Braun Drive P O Box 500 Beaverton OR 97077 USA For product information sales service and technical support m In North America call 1 800 833 9200 m Worldwide visit www tektronix com to find contacts in your area SS a Service Safety Summary RM4000 Rackmount Kit Only qualified personnel should perform service procedures Read this Service Safety Summary and the General Safety Summary in the product service manual or the instruction manual Do Not Service Alone Do not perform internal service or adjustments of this product unless a
6. acks See Figure 7 Remove this sectio from each track Figure 7 Prepare tracks for mounting 6 Install the front left and right side track sections on the instrument using four 6 32 x 0 250 inch pan head T 15 TORX drive screws tightened to 8 in Ib See Figure 8 Left side rack mount a Screws 4 Figure 8 Installing the left and right side track sections RM4000 Rackmount Kit 13 Installation Instructions 14 A WARNING To ensure that the rackmount track locks make sure the track button latches are oriented correctly the right side latch is located toward the bottom of the rackmount panel and the left side latch is located toward the top of the rackmount panel Refer to Figure 9 If the button latches are not oriented correctly the instrument could slide from the rack which could cause injury or damage to the instrument Note Button latch is located near the bottom edge of right side track top edge for left side track Mount the tracks on the sides of the instrument Figure 9 Track orientation This completes the installation of the rack adapter hardware to the instrument To complete the installation do the following procedure Rackmount the Rack Adapted Instrument RM4000 Rackmount Kit Installation Instructions Rackmount the Rack Adapted Instrument A Install Track Assembly and Instrument into the Rack RM4000 Rackmount Kit This procedur
7. e assembles and installs the slide out tracks in the equipment rack and then installs the rack adapted instrument in the rack The slide out tracks permit the rack adapted instrument to be extended out of the rack for rear panel and connector maintenance without removing the instrument from the rack WARNING To prevent the rackmounted instrument from tipping forward onto the operator install the instrument so that the operator will be able to access all of its rear devices without pushing down on the instrument Verify that the rack does not become unstable with the instrument fully extended Do not leave the instrument extended when finished accessing the rear panel Equipment Required One screwdriver handle one number two PoziDriv tip and one torque driver NOTE The rack hardware kit contains hardware for mounting the instrument in several configurations Not all of the hardware in the kit will be needed A standard equipment rack has rails with universal hole spacing If you use a rack with other than universal hole spacing you may have to drill additional mounting holes in the rack Procedure 1 Assemble the slide out track a Measure the distance between the front and rear rail of the equipment rack b Align the rear bracket to the right slide out track as shown in Figure 10 Note that the rear bracket has multiple pairs of mount through holes When aligning the bracket and track be sure to select a pair of
8. ecuring holes 111 125 mm 4 375 in NN gt Figure 11 Vertical clearances for rack installation left front rail shown RM4000 Rackmount Kit 17 Installation Instructions b Select mounting method according to rack type To mount the slide out tracks with their front and rear flanges outside of the front and rear rails use the mounting method A shown in Figure 12 when doing substep c Add a bar nut to the installation only if the rails have untapped holes To mount with front and rear flanges inside of rails use the mounting method B outlined in Figure 12 This mounting method assumes untapped holes c Install in rack Using the method and hardware determined from substep b secure the right slide out track assembly to its front and rear rails The screws should be fully but lightly seated so mounting can be adjusted later d Fix the length of the slide out track assembly Tighten the screws applying 28 inch lb of torque left loose in step 1 substep c to fix the front to rear flange spacing of the slide out track assembly e Mount the left slide out track assembly Repeat substeps c through d to mount the left slide out track assembly Outer track N Outer track Use a bar nut if front rails are not tapped Use a bar nut Front flange Front flange Left front l Left front rack rail English Metric rack rail 12 10 M6 M5 10 32 Flat head 10 32
9. he mains power before removing the cover Failure to do so could result in injury or death Installation Instructions Remove Equipment Required Screwdriver handle with T 15 tip This procedure prepares the instrument for installation of the rackmount parts NOTE Retain all parts removed from the instrument for later use Some of those parts will be reinstalled as you perform this rack conversion store the remain der in case reconversion to a standard instrument configuration is desired at a later time 1 Disconnect the power cord from the rear of the instrument 2 Remove the four T 15 TORX screws that secure the rear cover to the front case assembly See Figure 4 3 Remove the rear cover Remove 4 screws Se Pe A QS Front case assembly Rear case cover S Figure 4 Removal of rear case cover 10 RM4000 Rackmount Kit Installation Instructions Install Equipment Required Torque driver with T 15 and T 25 tips This section describes mounting the rackmount parts to the instrument NOTE Rackmount part appearance may vary from the illustrations 1 Install the left and right mounting plates on the instrument using four 6 32 x 0 250 inch pan head T 15 TORX drive screws tightened to 8 in Ib See Figure 5 Front case assembly Left mounting Right
10. he rack adapted instrument into a standard equipment cabinet All tools are standard tools that are readily available Table 3 Tools required for rackmount installation Name Description Screwdriver handle magnetic Accepts 1 4 inch hexagonal head driver tips No 2 Phillips or PoziDriv tip Phillips or PoziDriv driver tip for number 2 size screw heads T 10 TORX tip TORX driver tip for T 10 size screw heads flathead T 15 TORX tip TORX driver tip for T 15 size screw heads T 25 TORX tip TORX driver tip for T 25 size screw heads 1 4 inch wrench Wrench or nut driver can be used to install slides Torque driver 6 5 in long shaft accepts 1 4 inch hexagonal head driver tips These instructions are for qualified service personnel who are familiar with servicing the product If you need further details for disassembling or reassem bling the product refer to the appropriate product manual Contact your nearest Tektronix Service Center or Tektronix Factory Service for installation assistance WARNING To prevent the rackmounted instrument from tipping forward onto the operator install the instrument so that the operator will be able to access all of its rear panel connectors without pushing down on the instrument Verify that the rack does not become unstable with the instrument fully extended Do not leave the instrument extended when finished accessing the rear panel WARNING To avoid electric shock disconnect the power cord from t
11. nother person capable of rendering first aid and resuscitation is present To prevent the instrument and rack from falling onto the operator two or more installers should install the instrument into the rack cabinet After completing the installation procedure the installers should verify that the instrument and rack cabinet will not tip forward while the instrument is in the extended position Disconnect Power To avoid electric shock switch off the instrument power then disconnect the power cord from the mains power Use Care When Servicing With Power On Dangerous voltages or currents may exist in this product Disconnect power and disconnect test leads before removing protective panels soldering or replacing components To avoid electric shock do not touch exposed connections Service Safety Summary 2 RM4000 Rackmount Kit ERE T Kit Description This introduction describes the installation of the rackmount kit to your standard bench top instrument The rackmount kit is a collection of parts that once installed configure the instrument for mounting into a standard 19 inch equipment rack This document supports Tektronix modification ECR31404 Products DPO4000 Series All Serial Numbers MSO4000 Series All Serial Numbers Kit Parts List Table 1 lists the parts included in this rackmount kit The parts are shown in Figure 1 Table 1 RM4000 Rackmount kit see figure 1 on page 4 Item Quantity Partnumber
12. re left loose at the rear of the rack when you did step 2 substep c and then pull the instrument part way out of the rack Be sure that the four screws that were left loose at the front of the rack are loose enough to allow the slide out track assemblies to seek their normal positions Retighten the four screws and push the instrument all the way into the rack If the tracks do not slide smoothly readjust the level using the method just detailed When leveling is completed tighten the 10 32 screws using 28 inch Ib of torque 19 Installation Instructions Finishing the Installation It is recommended that you secure the instrument to the rack WARNING To prevent the rackmounted instrument from sliding forward and A N causing personal injury or instrument damage always secure the instrument to the rack if the rack is moved for example if the rack is repositioned or relocated to another room 4 Secure the instrument to the rack a Secure the instrument in the rack using four 10 32 x 0 625 in screws and rectangular washer spacers as shown in Figure 13 Rectangular washer spacer 4 Figure 13 Securing the instrument to the rack 85 End of document 5 20 RM4000 Rackmount Kit
13. s may not meet their warranted characteristics See the specifications for your instrument model for tables of the warranted characteristics Cooling air enters on the bottom and right sides as shown in Figure 2 You must provide adequate cool air to meet the ambient temperature requirements listed in Table 2 Q A A A o 9 S Hot air out rear gt S o O S a oO Ol 5 Ono JO SE 0 D SI pa ee DISO O O D S G Gr O OLO L o G OOO Measure C input air O 2 SES SSS gt fol fol fol fo o c O temperature o A A o 0 A L 0 S G Cool air in 2 0 G ED es S O Q O 2 o 2 o Figure 2 Instrument cooling Kit Description Environmental The following environmental characteristics supercede those listed in the Requirements specifications and performance verification sections of the manual for your instrument Table 2 Warranted characteristics Characteristic Description Temperature Inside Rack Cabinet Operating 10 C to 45 C 50 F to 113 F Nonoperating 22 C to 60 C 7 6 F to 140 F Shock Operating and Non operating 20 g 11 ms half sine each axis 3 drops each Clearance Requirements The rack in which the rack adapted instrument is mounted must provide the following clearance requirements m A minimum of 8 75 in 222 25 mm of vertical
14. space A minimum width of 17 72 in 450 09 mm between the left and right front rails in the rack A minimum depth of 12 75 in 323 85 mm CAUTION Adhering to these clearance requirements provides the rack mounted A N instrument with sufficient clearance for air circulation and accommodation of the power cord and mounting hardware Failure to provide these clearances can result in overheating and can cause instrument faults or failure 6 RM4000 Rackmount Kit Kit Description 429 51 mm 16 910 in A 559 56 mm 22 030 in 1 b 179 32mm 57 84 mm 7 060 in o o oo oo oo oo 2 277 in m a gt 486 03 mm 19 135 in 480 37 mm 18 912 in a 26 77 mm 1 054 in oO O conn OJ T D oo El S J 177 80 mm O AA OS 218 36 mm el LD 7 00 in Boo 8 597 in D 000084 S pa PRE I L e 465 02mm 18 308 in Figure 3 Instrument with rack adapter installed RM4000 Rackmount Kit Kit Description 8 RM4000 Rackmount Kit Py 4a eee Installation Instructions This section contains the procedures needed to rackmount a DPO4000 or an MSO4000 series instrument Minimum Tool and Equipment List A RM4000 Rackmount Kit The following tools are required to attach the rack adapter kit hardware install cabling hardware and mount t
Download Pdf Manuals
Related Search
Related Contents
71913 - S500-Touch DFE.indd HydraVision User`s Guide JA木曽平成25年度人事異動報告 ODYS Pro Q8+ GUÍA DE INICIO RÁPIDO Pill Assisted Living (PAL) 取扱説明書 (1.79 MB/PDF) Spectraflex Installation & User Manual Télécharger la fiche RGE Mode d`emploi 平成24年度のパンフレット Copyright © All rights reserved.
Failed to retrieve file