Home
REMOTE GSM SWITCH GRM-10
Contents
1. The device is designed for single phase installation and must be installed in accordance with standards valid in a particular country The device should CAUTION be connected according to the details included in this operating manual Installation connection and control should be car ried out by a qualified electrician staff who act in accordance with the service manual and the device functions In case of casing dismantling an electric shock may occur and the guarantee is lost then Before installation make sure the connection cables are not under voltage The cruciform head screw driver 3 5 mm should be used to instal the device Improper transport storage and use of the device influence its wrong functioning It is not advisable to instal the device in the following cases if any device part is missing or the device is damaged or deformed In case of improper functioning of the de vice contact the producer The symbol means selective collecting of electrical and electronic equipment It is forbidden to put the used equipment together with other waste A TECHNICAL PARAMETERS GRM 10 Nominal input rated voltage Input voltage tolerance Nominal power consumption GSM frequency Operating range Supply voltage optical signalling GSM status signalling Output number Output status signalling Output relays parameters Input number Input type Interfaces RS485 transmission signa
2. EF RESET Deleting the control command table for EXTA FREE system RESET CONFIG Restore the default settings it does not refer to EXTA FREE commands CONFIGURATION MODE COMMAND The command makes the GRM 10 device enters from the normal operation mode into the remote configuration mode The active com mand is only for the numbers included in the ADMIN list by means of ADMIN command or the PC application The enter into the con figuration mode is indicated by a flashing LED diodes LEDP1 and LEDP2 CONFIGURATION MODE END COMMAND The command allows the the GRM 10 device to go out from the configuration mode to normal operation The active command is only for the numbers included in the ADMIN list by means of ADMIN command or the PC application The command is inactive during local configuration ADD NUM COMMAND The command adds a telephone number numbers to the authorised list of numbers used to control CLIP including the control in the gate mode 6 telephone numbers maximally can be added by one command at each time The command refers to the local and remote configuration ADD NUM lt 48tel_1 gt lt 48tel_2 gt lt 48tel_n gt tel_1 tel_n successively entered phone numbers preceded by 48 The maximum of numbers available n 6 Examples of commands Command Description Number 48602360938 is added to the authorised list of numbers ADD NUM 48602360338 used to c
3. Example EF K1 K2 K3 SALON OFF Due to the queuing prioritisation of text messages in the GSM network some delays related to sending the control command and its realisation are possible for example the adjustment of the GRM 10 outputs or EXTA FREE receivers The delays can be from several to tens o seconds Due to the representation of the text message content the configuration and control of the GRM 10 device is not possible by means of SMS gateways that are provided by the GSM operators In case of operators using other resources of the GSM network it is not possible to choose the operator manually The logging procedure is automatical the operator with the strongest signal is chosen Successful login of the GRM 10 device to the GSM network is indicated by a flashing LED GSM STATUS diode with a frequency of 1 s Make sure that the device is mounted in areas with the GSM network reception Operation on the reception border can have a negative influence on a proper operation of the GRM 10 device and other devices in cooperation It is important to switch off the PIN code or adjust the code to 1111 before installing the SIM card in the GRM 10 device e It is recommended to switch of the VOICEMAIL service on the card installed in the GRM 10 DEVICE
4. IN1 IN2 inputs are not configurated in the gate mode The inputs have the following default settings e The appearance of a short pulse in the IN1 input results in switching on the OUT1 output for the time lt TIME1 gt that is adjusted during the gate mode configuration e The appearance of a short pulse in the IN2 input results in switching on the OUT2 output for the time lt TIME2 gt that is adjusted during the gate mode configuration Examples of commands Command Description GATE 2 15 RING 2 time1 2 s time2 15 s setting the CLIP after 2 rings GATE 2 10 RING 2 AUTO 350 time1 2 s time2 10s setting the CLIP after 2 rings automatically generat ing pulse to close the gate after time3 350 s GATE 2 100 time1 2 s time2 100 s control only by means of tex messages GATE 0 60 Pulse generation only to open the doorway latch operation time 60 s GATE 20 Pulse generation only to open the gate pulse time 2 s Manual control of the gateway L N MCM Manual control GRM 10 of the doorway A B C 14 24 C lt time1 gt GATE lt time3 gt CONTROLLER Tee if the parameter AUTO is set ELECTRIC LATCH OF THE DOORWAY The GRM 10 connection diagram in the gate mode TASK IN 1 TASK IN 2 COMMAND TASK IN1 lt LO HI gt RELAY1 lt ON OFF gt or TASK IN2 lt LO HI gt RELAY2 lt ON OFF gt TASK IN1 lt LO HI gt RELAY1 TIME lt t1 gt or TASK IN2 lt LO HI gt RELAY
5. If the AUTO parameter is adjusted for the gate mode the pulse to close the gate is automatically generated after time lt TIME3 gt is finished Times lt TIME1 gt lt TIME2 gt and lt TIME3 gt are adjusted during the gate mode configuration Output control in the gate mode Switching on the OUT1 output for time lt t1 gt and the OUT2 out put for time lt t2 gt The lt t1 gt parameter is adjusted in the range of 0 10 and the lt t2 gt parameter GATE lt t1 gt lt t2 gt in the range of 0 360 If the AUTO parameter is adjusted for the gate mode the pulse to close GATE 2 120 the gate is automatically generated after time lt TIME3 gt is finished Time lt TIME3 gt is adjusted during the gate mode configuration STATUS Checking the output input status section GRM 10 DEVICE REPLY TO STATUS COMMAND CAUTION If the PASS parameter password to a text message was adjusted during configuration in the CONFIG command then the adjusted password must be typed during the text message control at the beginning Example adjusted password Zamel camel RELAY1 ON Zamel RELAY2 OFF Zamel RELAY1 TIME 10 Zamel GATE Zamel GATE 2 20 RELAY1 TIME lt t gt RELAY2 TIME lt t gt GRM 10 DEVICE REPLY TO STATUS COMMAND A full GRM 10 device reply to STATUS command RELAY1 lt ON OFF current OUT1 output status gt TIME lt Time left to measure for OUT1 output
6. in a single point the shield line The resistors terminators of 120 Ohm should be placed at the beginning and at the end of the line he following points should also be carried out 1 Connect the RXM 01 device to a PC An appropriate adapter RS232 RS485 or USB 485 depending on the computers output should be used 2 Using the PC application that is dedicated to configure the GRM 10 device particular control commands and responding number of push buttons shall I be defined in the EXTA fREE section For each command specify The RXM i GRM 10 01 address for the MODBUS bus should be defined The default address is D eee 0x01 The address is important for a larger number of RXM 01 operating independently on a single object Following the description of the PC add programme particular push but tons sent by the RXM 01 device to appropriate EXTA FREE system receiv ers After programming the receivers use the PC application to check their ap propriateness Adjust the GRM 10 device into a normal operation mode and check the operation by sending defined control commands to the GRM 10 device the proper communication between RXM 01 and GRM 10 after sending a con trol command is indicated by the LED diode RS485 it switches on IN1 C IN2 If in the EXTA FREE control command several push buttons are defined the codes are sent to RXM 01 device with a defined address in a sequence one after another and with an interval of 1 sec
7. switched on permanently or only for lt t1 gt lt t2 gt time It can be switched off by means of a CLIP or a TEXT MESSAGE any time In case of MEM parameter adjustment in RELAY1 RELAY2 configuration commands for a selected output the adjustment remembered for inputs in the time mode is the status before activation of the lt t1 gt lt t2 gt TASK IN1 lt LO HI gt NONE MESSAGE lt text message content up to 30 signs gt TASK IN2 lt LO HI gt NONE MESSAGE lt text message content up to 30 signs gt MESSAGE A keyword it defines the text message content to be sent by the GRM 10 device to its receivers Their telephone numbers are configured in the INFO command The text message can include up to 30 signs The occurrence of a specific status lt LO HI gt in the input results in sending a text message TASK INx lt LO HI gt RELAYx lt ON OFF TIME gt lt tx gt MESSAGE lt text message content up to 30 signs gt The command makes the connection between the specific status occurrence LO HI in the IN1 IN2 input with an appropriate activation of the OUT1 OUT2 output and sending a text message MESSAGE with a defined content X number of an input output 1 input output IN1 OUT1 2 input output IN2 OUT2 lt tx gt f the output must be active for a period of time TIME then the parameter defines time for the time mode This parameter is config ured in the range of 1 to 3600 Examples of commands Command Description TASK IN
8. telephone number included on the ADMIN list By receiving the above text message the GRM 10 device will send back a reply CONFIG MODE OK and will enter the configuration mode which is indicated by flashing red LED diodes LEDP1 and LEDP2 Carry out the device configuration in accordance with the CONFIGURATION COMMANDS Send a TEXT MESSAGE with the CONFIG MODE END content to leave the remote configuration mode By receiving the above text message the GRM 10 device will send back a reply CONFIG MODE END OK and will enter a usual operation mode When entering leaving the remote configuration mode the outputs status remains unchanged Configuration by means of the PC application via an MIC RO USB interface NOTE Every time before making any changes in the configuration settings by means of the PC application first read the current configu ration of the GRM 10 device It is necessary not to overwrite or lose the configuration settings implicated by the telephone text message 1 Start the GRM 10 application on PC 2 Switch off the power supply to connect the MICRO USB to the GRM 10 device Wait until the GRM 10 device appears in the operating system to install properly READ CURRENT GRM 10 DEVICE CONFIGURATION Carry out change the configuration adjustments by means of the PC application In order to save the current configuration of the GRM 10 device press the ZAPISZ DO URZ DZENIA push button Press shortly
9. 1 LO RELAY1 ON After LO status appears in IN1 input the OUT1 output switches on TASK IN1 HI RELAY2 OFF After HI status appears in IN2 input the OUT2 output switches off After LO status appears in IN2 input the OUT1 output status changes for 30 sec After HI status appears in IN1 input the OUT2 output status changes for 10 sec TASK IN1 LO NONE After LO status appears in IN1 input no GRM 10 reaction TASK IN2 HI NONE After HI status appears in IN2 input no GRM 10 reaction TASK IN1 LO NONE MESSAGE After LO status appears in IN1 input the WODA W POMIESZCZENIU mes WODA W POMIESZCZENIU sage is sent TASK IN1 HI NONE MESSAGE After HI status appears in IN1 input only the WODA WYPOMPOWANA WODA WYPOMPOWANA message is sent TASK IN1 LO RELAY1 ON MESSAGE After LO status appears in IN1 input the OUT1 output switches on and a text STAN NISKI NA IN1 message STAN NISKI NA IN1 is sent TASK IN2 LO RELAY2 TIME 60 MESSAGE After LO status appears in IN2 input the OUT2 output changes for time t 60 ODLICZANIE CZASU sec a text message ODLICZANIE CZASU is sent TASK IN2 LO RELAY1 TIME 30 TASK IN1 HI RELAY2 TIME 10 J WARRANTY CARD There is 24 months guarantee on the product 1 ZAMEL Sp z 0 0 assures 24 months guarantee for the product a 2 The manufacturer s guarantee does not cover any of the following actions a mechanical damage during transport loading unloading or
10. 2 TIME lt t2 gt TASK IN1 lt LO HI gt NONE or TASK IN2 lt LO HI gt NONE KEYWORDS TASKI IN1 TASK IN2 defines the output the configuration refers to RELAY 1 RELAY2 defines the output that must be activated after a given status occurance in the input TIME defines that after an occurrence of the lt LO HI gt status in IN1 IN2 input the OUT1 OUT2 output changes its status for a time limited by lt t1 gt lt t2 gt parameters NONE defines that after an occurrence of the lt LO HI gt status in IN1 IN2 input the GRM 10 device avoids the status it does not re spond PARAMETERS lt LO HI gt A parameter for the keyword TASK IN1 TASK IN2 defining the level of the input IN1 IN2 that activates a specific output oc currence The normal status of the IN1 IN2 inputs is the high state HI The low status is achieved by linking the selected input to terminal C lt ON OFF gt A parameter for the RELAY1 RELAY2 keyword it defines the output status ON the output is on OFF the output is off lt t1 gt Time s of the OUT1 OUT2 output after a defined status occurred in IN1 input This parameter is configured in the range of 1 to 3600 lt t2 gt Time s of the OUT1 OUT2 output after a defined status occurred in IN1 input This parameter is configured in the range of 1 to 3600 CLIP or TEXT MESSAGE control have a higher priority than inputs It means that if a specific status occurs in IN1 IN2 inputs the OUT1 OUT2 output is
11. REMOTE GSM SWITCH GRM 10 MANUAL INSTRUCTION exta free A XX ZAMEL Sp z 0 0 ul Zielona 27 43 200 Pszczyna Poland Tel 48 32 210 46 65 Fax 48 32 210 80 04 www zamelcet com e mail marketing zamel pl za MeL DESCRIPTION The GRM 10 device is designed to realise simple control and notice opera tions The operations are carried out by means of the GSM network The control ler has two independent outputs with a maximum load capacity of 16 A 250 V AC Two digital inputs allow for a link with the alarm control panels The RS485 in terface in connection with the RXM 01 translator gives a possibility to control EXTA FREE system receivers with the help of a mobile phone and messages that are defined by the user The number of operation modes and configuration options make the GRM 10 a very useful device for simple home automation and industrial systems The GRM 10 device is made in a three MOD casing and is designed for mounting in switchboards on a TH35 rail S Remote control of the electrical de vices by means of commands in coming phone connection text mes sage sent from a mobile phone Comfortable control of difficult ac cess devices air conditioning heat ing etc Two relay outputs with the load ca pacity of 16 A Operation is optically signalled pow er supply relay status GSM modem status Low power consumption a possibility of continuous operation
12. ROLETY DOL address to press a 0x0 4 push button It results in closing the roller blind connected to SRP 02 with this code A text message with the content ALL ON results in switching on the light and opening the roller blinds it is equivalent to sending codes by RXM 01 with the 0x0 1 address to receivers to press 0x0 1 EF 1 K1 OSWIETLENIE ON EF 1 K2 OSWIETLENIE OFF EF 2 K3 SCHODY ON EF 2 K4 SCHODY OFF EF 1 K1 K3 ALL ON example of a stage Salesman stamp and signature date of sale otherwise are not affected by this warranty J iy and 0x0 3 push buttons Ne OUTPUT CONTROL COMMANDS S Command Description Przyk ad RELAY1 ON Switch on OUT1 output RELAY1 OFF Switch off OUT1 output RELAY2 ON Switch on OUT2 output RELAY2 OFF Switch off OUT2 output RELAY1 TIME Change of OUT1 output status for time t1 s adjusted during configuration RELAY2 TIME Change of OUT2 output status for time t2 s adjusted during configuration Change of OUT1 output status for time lt t gt given in the control command lt t gt parameter is ad RELAY1 TIME 60 justed in the range of 1 3600 Change of OUT2 output status for time lt t gt given in the control command lt t gt parameter is ad RELAY2 TIME 10 justed in the range of 1 3600 Output control in the gate mode Switching on the OUT1 output for the default time lt TIME1 gt and the OUT2 output for the default time lt TIME2 gt
13. The confirming text messages are sent only if the ACK parameter is set in the CONFIG command Sending the INFO command with new telephone numbers results in deleting the previous numbers and writing the new ones Examples of commands Command Description Text messages will be sent to the following numbers 48602360938 INFO 48602360938 48600915257 48600915257 confirming the realization of a specified control command or occurences on inputs Text messages will be sent to the following numbers 48602360938 INFO 48602360938 48600915257 48600500800 48600915257 48600500800 confirming the realization of a specified control command or occurences on inputs XR a RELAY1 RELAY 2 COMMAND RELAY1 lt ON OFF MEM gt lt mode gt lt t1 gt RING lt y gt RELAY2 lt ON OFF MEM gt lt mode gt lt t2 gt RING lt y gt lt ON OFF MEM gt The parameter defines the output status OUT1 OUT2 after switching on power supply from the mains ON Output switched on OFF Output switched off MEM GRM 10 remembers the output status when the power supply is switched off and then switched on again the output has the same status as it was before the power supply switch off The parameter is not adjusted for the TIME mode lt mode gt A parameter that defines the operating mode of OUT1 OUT2 outputs it is default for CLIP control ONOFF Bistable mode Switch on switch off TIME Time mode lt t1 gt lt t2 gt A paramet
14. able in the range of 0 to 10 OUT1 task is to generate a pulse to the gateway controller If this parameter is set to 0 then OUT1 output is inactive lt TIME 2 gt A parameter that defines the default time s of the OUT2 output configurable from 0 to 360 The OUT2 output task is to pro vide voltage supply to the electric latch If this parameter is set to 0 then the OUT2 output is inactive RING A keyword that defines the number of rings to control outputs in the gate mode by means of a CLIP lt y gt A parameter that defines the number of rings to control outputs in the gate mode by means of a CLIP This parameter is con figured in the range of 2 to 6 If it is not set the control is carried out only by means of text messages AUTO Akeyword to configure the AUTO mode In the AUTO mode after lt TIME 3 gt finishes a gate controller s pulse is au tomatically generated for a defined lt TIME1 gt time This impulse is to automatically close the door If the AUTO mode is ac tivated the gate remains open till the GATE command is activated till the next CLIP a till the next pulse in IN1 input or till another pressing of the PK1 push button lt TIME3 gt A parameter that defines the time s during which the gate remains open The time is measured after lt TIME1 gt finishes It is configured in the range from 1 to 600 While adjusting lt TIME3 gt it is necessary to take into consideration the time taken to open the gate
15. dded to the text message during control The password is added at the beginning of the message No parameter means a free access for any number during text message control ACK Keyword it specifies whether the GRM 10 device must send a confirming text message every time after a specified command is realised REL1 confirmation only for CH1 channel REL2 confirmation only for CH2 channel REL12 confirmation for channels CH1 and CH2 lt gt No parameter means no confirmation for channels CH1 and CH2 Examples of commands Command Description Numbers 48602360938 48600915257 globally released to CONFIG 48602360938 48600915257 control CLIP no password for text message control no confirma tions for OUT1 and OUT2 outputs Numbers 48602360938 48600915257 globally released to CONFIG 48602360938 48600915257 ACK REL1 control CLIP no password for text message control confirmations only for OUT1 output Numbers 48602360938 48600915257 globally released to CONFIG 48602360938 48600915257 ACK REL2 control CLIP no password for text message control confirmations only for OUT2 output Numbers 48602360938 48600915257 globally released to CONFIG 48602360938 48600915257 ACK REL12 control CLIP no password for text message control confirmations for OUT1 and OUT2 outputs Numbers 48602360938 48600915257 globally released to CONFIG 48602360938 48600915257 PASS ZAMEL ACK REL1 control CLIP ZAMEL password for text m
16. ed in the range of 1 to 247 lt K1 Kn gt The parameter defines the the number of push buttons used to control EXTA FREE system receivers possible numbers from 1 to 127 In one EF command up to 15 numbers of push buttons can be configured The push buttons refer to a single control text message for example in order to adjust several EXTA FREE system receivers by means of one text message lt control text message content gt The control command is adjusted by a user the maximum number of signs is 32 The user can define 127 independent control commands The commands can not be repeated if the command including a given content already exists the GRM 10 device will display ERROR as a response to this configuration text message A similar message is given by the PC application The control commands generated by the EF command are grouped in a table Commands generated as text mes sages are placed at the end of the table and from a PC at the beginning It should be helpful for the user to add new commands by means of a telephone The maximum number of EF commands that can be configured is 127 The EF commands table can be completely deleted by sending a EF RESET command in the configuration mode The user can configure the EF command in such a way as to adjust simultaneously several up to 15 EXTA FREE LEDIX system receiv ers which are located within RXM 01 range It is very important in creation the so called scenes or for example in the con
17. er that defines default times s for the time mode possible value from 1 to 3600 RING A keyword defining the number of ring signals to control CLIP lt y gt A parameter defining the number of rings to control CLIP The parameter is adjusted in the range of 2 to 12 NS If the RING keyword and lt y gt parameter is not adjusted the control is carried out only by sending text messages OUT1 OUT2 outputs are independently configurable Examples of commands Command Description RELAY1 ON ONOFF RING 3 OUT1 output is switched on bistable mode adjustment after three rings OUT1 output in the status before power supply switch off bistable mode acti vation after two rings OUT1 output is switched off time mode time 60 seconds adjustment after 4 rings RELAY2 OFF ONOFF e output is switched off bistable mode control only by means of text mes RELAY2 ON TIME 10 RING 2 Ta is switched on time mode time 10 seconds adjustment after A RELAY1 MEM ONOFF RING 2 RELAY1 OFF TIME 60 RING 4 MODBUSCONFIG COMMAND Default MODBUS protocol configuration in GRM 10 device allows for a direct connection with EXTA FREE translator RS 485 RXM 01 type GRM 10 device in such a connection is only a MASTER on the MODBUS bus it receives control text messages and by means of RS 485 bus it sends appropriate commands to the RXM 01 device A default configuration Protocol MODBUS RTU 8 bits of data Parit
18. essage control confir mations only for OUT1 output NOTE If there is a need to add more authorised numbers to control the CLIP including control in the gate mode it can be done by means of the PC application telephone section or the ADD NUM command in configuration mode It is possible to enter up to 500 numbers In order to delete the selected telephone number use the PC application or the DEL NUM command in configuration mode p Deleting a number s from the list of telephone numbers authorized to control the CLIP Every time by DEL NUM s means of one command up to six numbers may be deleted It refers to local and remote configuration ADMIN Configuration of telephone numbers authorized to a remote configuration Configuration of telephone numbers the text messages will be sent to it refers to the outputs status INFO and occurrences on IN1 IN2 inputs RELAY1 Operation mode configuration for CH1 output Operation mode configuration of CH1 output after power supply voltage is switched off Operation mode configuration for CH2 output REFAYZ Operation mode configuration of CH2 output after power supply voltage is switched off MODBUSCONFIG Configuration of RS485 transmission parameters for MODBUS protocol GATE Gate mode configuration TASK IN1 IN1 input configuration TASK IN2 IN2 input configuration XX EF Control command configuration for EXTA FREE system
19. essage with a control command to the device Times for the TIME and GATE modes are adjusted during configuration with a possibility of changing the text in the control text message ON OFF bistable mode change of the CH1 or CH2 output status to the opposite TIME time mode change of the CH1 or CH2 output status to the opposite and appropriately through time t1 for CH1 output and time t2 for CH2 output GATE gate mode change of the CH1 and or CH2 into times defined for the gate mode EXTA FREE control control of EXTAFREE system wireless receivers by means of RXM 01 device RXM 01 connected with the GRM 10 device CONFIGURATION COMMANDS A Command Description Configuration of telephone numbers authorized to control the CLIP CONFIG Configuration of the optional password for controlling text messages Configuration of confirmation CONFIG MODE Adjusting the device for the remote configuration mode CONFIG MODE END Deleting the remote configuration mode Entering additional phone numbers to the list of numbers authorised to control the CLIP By means of ADD NUM one commend maximum six numbers can be added every time Applies to local and remote configura tion CONFIG COMMAND CONFIG lt 48tel_1 gt lt 48tel_n gt PASS lt password from 5 to 8 signs gt ACK lt REL1 REL2 REL12 gt The maximum of numbers available n 6 PASS Keyword it specifies the password a
20. evice makes the local and remote configuration possible The remote configura tion allows to manage the settings of the already working GRM 10 device without a physical access to it for example to a device that is installed in the building The configuration can be done as follows a by means of a mobile phone via text massage local and remote configuration b by means of the PC application via the Micro USB interface only the local configuration Local configuration by means of a mobile phone 1 Press the PK2 push button on the front panel 2 Switch on the power supply and keep the PK2 push button pressed 3 Hold the PK2 push button as long as the LED red diodes LEDP1 and LEDP2 start flashing 4 Wait until the GRM 10 device logs into the GSM network LED yellow diode GSM flashes 5 Adjust the configuration parameters by sending appropriate text messages see CONFIGURATION COMMANDS 6 Switch off the power supply from the mains Remote configuration by means of a mobile phone The remote configuration is available only for these telephone numbers that have been added to the so called administrative numbers list by means of the configuration command ADMIN see CONFIGURATION COMMANDS during the local configuration by means of a text message or a PC application The remote configuration is possible during a usual device operation if it is logged in to the GSM network Send a text message with a CONFIG MODE content from a
21. gt RELAY2 lt ON OFF current OUT2 output status gt TIME lt Time left to measure for OUT2 output gt IN1 lt LO HI current IN1 input status gt IN2 lt LO HI current IN2 input status gt Example RELAY1 ON TIME 30 RELAY2 OFF TIME 100 IN1 LO IN2 HI If times for OUT1 OUT2 outputs are currently not measured the reply to the STATUS command is RELAY1 lt ON OFF current OUT1 status gt RELAY2 lt ON OFF current OUT2 status gt IN1 lt LO HI current IN1 status gt IN2 lt LO HI current IN2 status gt or RELAY1 lt ON OFF current OUT1 status gt TIME lt 0 gt RELAY2 lt ON OFF current OUT2 status gt TIME lt 0 gt IN1 lt LO HI current IN1 status gt IN2 lt LO HI current IN2 status gt Example RELAY 1 ON RELAY 2 OFF IN1LO IN2HI RELAY 1 ON TIME 0 RELAY 2 OFF TIME 0 IN1LO IN2HI CONTROL OF EXTA FREE SYSEM RECEIVERS The GRM 10 device by receiving certain commands text messages can control the wireless EXTA FREE system receivers It is neces sary to connect the GRM 10 device with RXM 01 translator using the RS 485 interface The GRM 10 device has such a default setting that allows for a direct cooperation with RXM 01 If the transmission parameters change is necessary standard transmission rate parity between GRM 10 and RXM 01 use the MODBUSCONFIG command CAUTION The transmission line between the GRM 10 device and the RXM 01 device is a two wire shielded twisted pair cable it is recommended to earth
22. le phase installation must be done in accord ance with standards valid in a particular country The device should be connected according to the details included in this operating manual Installation con nection and control should be carried out by a quali fied electrician staff who act in accordance with the service manual and the device functions Disconnect power supply by the phase fuse the cir cuit breaker or the switch disconnector combined to GRM 10 01 the proper circuit A BC 14 240C Check if there is no voltage on connection cables by means of a special measure equipment Connect the GRM 10 device to 230 V AC power sup ply Connect the remaining cables with the appropriate terminals of the GRM 10 controller according to the installing diagram Insert into the SIM input the active SIM card with funds available Before installing switch off the PIN code or adjust it choosing 1111 It is recom Optional element mended to switch off the voice mail to control Carry out a proper device configuration see DEVICE EXTA FREE CONFIGURATION receivers Switch on the power supply from the mains Wait until the proper GSM network log in Check the correctness of the operation gt IN1 C IN2 DEVICE CONFIGURATION GRM 10 has a default factory settings Before use carefully read the manual instruction and make a proper device configuration In order to freely manage the configuration settings the GRM 10 d
23. lling Position on RS485 bus 230 V AC 50 60 Hz 15 10 1 5W 900 1800 1900 MHz restricted by the GSM network LED diode green LED diode yellow 2 2 x LED diode 2 x NO 16 A 250 V AC AC1 4000 VA 2 Digital potential 4 V RS485 MODBUS A B C terminals USB PK1 PK2 push buttons LED diode only MASTER Ambient temperature range Operating position Casing mounting Casing protection degree Protection class Overvoltage category Pollution degree Dimensions Weight 10 55 C free TH35 rail IP20 PN EN 60529 Il Il 2 3 modular casing 163g Reference standard PN EN 60950 1 2007 PN EN 55024 2000 PN EN 61000 4 4 APPEARANCE GSM range signalling SIM card input GSM antenna Power supply terminals Input terminals Power supply signalling MEE E E L N MCN Relay 1 LEDP1 status signalling Ps Relay 2 LEDP2 status signalling RS 485 transmission signalling kZ MICRO USB input PK1 PK2 push buttons C E47 Output terminals RS485 Interface J plik inst_ext_pl_grm 10_gb modyfikacja 03 06 2013 SOFTWARE UPGRADE The GRM 10 user has the ability to upgrade the software using the Micro USB interface It may be necessary in case of an upgrade The upgrade is carried out by the GRM 10 application on the PC 1 After switching off the po
24. ontrol by means of CLIP calling signals Numbers 48603360928 48600915257 48600500800 are add ADD NUM 48603360928 48600915257 48600500800 ed to the authorised list of numbers used to control by means of CLIP calling signals A DEL NUM COMMAND The command deletes a telephone number numbers from the authorised list of numbers used to control CLIP including the control in the gate mode 6 telephone numbers maximally can be deleted by one command at each time The command refers to the local and remote configuration DEL NUM lt 48tel_1 gt lt 48tel_2 gt lt 48tel_n gt tel_1 tel_n successively entered phone numbers preceded by 48 The maximum of numbers available n 6 Examples of commands Command Description Number 48602360938 is deleted from the authorised list of num DELNUM 48602360338 bers used to control by means of CLIP calling signals Numbers 48603360928 48600915257 48600500800 are de DEL NUM 48603360928 48600915257 48600500800 leted from the authorised list of numbers used to control by means of CLIP calling signals INFO COMMAND INFO lt 48tel_1 gt lt 48tel_2 gt lt 48tel_n gt tel_1 tel_n successively entered phone numbers preceded by 48 The text messages will be sent to these numbers The confirma tions refer to the changed output status and occurences on IN1 IN2 inputs The maximum of numbers available n 6
25. the PK1 push button on the front panel of the GRM 10 device LED yellow diode RS485 switches on for a moment If the configuration is correct the application sends back a message CONFIGURATION OK Otherwise the message CONFIGURA TION ERROR displays 9 Disconnect the MICRO USB cable from the GRM 10 device Saving the configuration to zml file The current configuration can be saved to a zml file In order to do it by means of the application press the ZAPISZ DO PLIKU push button and select the proper file place to save it Reading the configuration from the zml file The current configuration can be read from the zm file In order to do it by means of the application press the WCZYTAJ Z PLIKU 4 DEVICE CONTROL Type of control Possible control types Remarks MANUAL Bistable ON OFF By means of PK1 PK2 push buttons on Time TIME the front panel Gate GATE Times for TIME and GATE modes are adjusted during con figuration Times for TIME and GATE modes are adjusted during con figuration The number of signals specified during configuration in ON OFF and TIME modes the user must disconnect after certain number of signals in the GATE mode the discon nection is automatical CLIP Bistable ON OFF By calling to the device Time TIME specified number of signals Gate GATE Bistable ON OFF Time TIME Gate GATE EXTA FREE control TEXT MESSAGE By sending a specified m
26. trol of central roller blind drives The next push buttons codes are sent in a one by one sequence with an interval of 1 second The cooperation of GRM 10 device with RXM 01 device is fully described in the EXTA FREE CONTROL section by means of GSM Examples of commands Command Description A text message with the content OSWIETLENIE ON results in sending a code by RXM 01 with the 0x0 1 address to press a 0x0 1 push button The result is that the receiver with this code is switched on A text message with the content OSWIETLENIE OFF results in sending a code by RXM 01 with the 0x0 1 address to press a 0x0 2 push button The result is that the receiver with this code is switched off A text message with the content SCHODY ON results in sending a code by RXM 01 with the 0x0 2 address to press a 0x0 3 push button The result is that the receiver with this code is switched on A text message with the content SCHODY OFF results in sending a code by RXM 01 with the 0x0 2 address to press a 0x0 4 push button The result is that the receiver with this code is switched on A text message with the content ROLETY GORA results in sending a code by RXM 01 with the 0x0 1 EF 1 K3 ROLETY GORA address to press a 0x0 3 push button It results in opening the roller blind connected to SRP 02 with this code A text message with the content ROLETY DOt results in sending a code by RXM 01 with the 0x0 1 EF 1 K4
27. under other circumstances b damage caused by incorrect product mounting or misuse c damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices needed for the product functioning d damage caused by Act of God or any other incidents independent of the manufacturer ZAMEL Sp z 0 0 e power source batteries in the device during sale if any 3 The PURCHASER shall lay any claims in writing to the dealer or ZAMEL Sp z 0 0 4 ZAMEL Sp z 0 0 is liable for processing any claim according to current Polish legislation 5 ZAMEL Sp z 0 0 shall process the claim at its own discretion product repair replacement or money return 6 The manufacturer s guarantee is valid in the Republic of Poland 7 The PURCHASER s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or A he command allows to configure text messages used to control EXTA FREE system wireless receivers and selected LED lighting fittings and controllers of intelligent lighting Ledix series system The control is possible only when the GRM 10 device is connected with the RXM 01 translator www extafree pl by means of RS 485 bus EF lt address gt lt K1 Kn gt lt control text message content gt lt address gt This parameter defines the RXM 01 translator address on MODBUS bus that the specific control command refers to This parameter is configur
28. wer supply voltage connect the GRM 10 device to the PC by means of a USB Micro B USB cable and pressing the PK2 push button 2 Start the GRM 10 application and select the UPGRADE window 3 Select Software Upgrade and then select the latest version of the GRM 10 software the ZMS from a specific location 4 If the software is successfully updated the application will show a comment The software has been updated 5 Press OK 6 Disconnect the USB Micro B USB A cable 7 Switch on the power supply release by the producer Information on the current software can be found on the product website http Awww zamelcet com pl 263 4537 sterownik_gsm_modulowy_2kanalowy_grm10 html Konfiguracja Upgrade Instrukcja Stan urz dzenia Tryb upgrade dysk E Wybierz plik oprogramowania Szukajw Prezenca a eade 21 Aplikacja GRM 10_ 5 04 zms Moje biezace BERTAS dokumenty ate X Moje dokumenty M j komputer Moje miejsca Nazwa pliku GRM 10_ 5 05 v sieciowe Pliki typu Pliki oprogramowania GRM 10 zms X E GRM 10 Konfiguracja _ Upgrade m GRM 10 2R Oprogramowanie zosta o zaktualizowane eee e Stan urz dzenia Tryb upgrade dysk E push button next choose the correct file place to read it CONNECTION AND INSTALLING DIAGRAM CAUTION The GRM 10 controller connection to a sing
29. y Parity bit stop bit Transmission rate 9600 kbps Address on the bus ox01 MODBUSCONFIG lt address gt lt rate gt PARITY lt parity options gt lt address gt A parameter defining address on the bus 1 247 lt rate gt A parameter defining transmission rate on the RS 485 bus 2400 2400 kbps 4800 4800 kbps 9600 9600 kbps 19200 19200 kbps PARITY A keyword defining parity options Selection possibilities NO no parity ODD odd test EVEN parity test Examples of commands Command Description MODBUSCONFIG 1 9600 PARITY EVEN Address 0x01 transmission rate 9600kbps parity test MODBUSCONMFIG 1 2400 PARITY ODD Address 0x01 transmission rate 2400kbps odd test GATE COMMAND GATE MODE In the gate mode the settings are as follow OUT1 it cooperates with the existing gate controller that controls the gateway OUT2 it cooperates with the electric latch opening the entry gate to the possession The number of telephones authorized to control in the gate mode by means of a ring CLIP are adjusted in the CONFIG configuration mode up to 6 numbers or by means of e the ADD NUM command in the configuration mode e the PC application in the Telephones section CLIP up to 500 numbers in the configuration mode GATE lt TIME 1 gt lt TIME2 gt RING lt y gt AUTO lt TIME3 gt lt TIME 1 gt Aparameter that defines the default time s of the OUT1 output configur