Home

ARUF**14 - Goodman

image

Contents

1. EM__ EVAPORATOR MOTOR RC__ RUN CAPACITOR SR STRAIN RELIEF RELAY EBTDR ELECTRONIC BLOWER TIME NOTES DELAY RELAY 1 RED WIRES TO BE ON TRANSFORMER TERMINAL 3 FOR 240 VOLTS AND ON TERMINAL 2 FOR 208 VOLTS 2 SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS TR TRANSFORMER PLF__ FEMALE PLUG CONNECTOR PLM MALE PLUG CONNECTOR FL __ FUSE LINK THERMAL LIMIT __ HEAT ELEMENTS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS 3 CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION IF SPEED TAP NEEDS TO BE CHANGED CONNECT APPROPRIATE MOTOR WIRE RED FOR LOW BLUE FOR MEDIUM AND BLACK FOR HIGH SPEED ON COM CONNECTION OF THE EBTDR INACTIVE MOTOR WIRES SHOULD BE CONNECTED TO M1 OR M2 ON EBTDR 4 BROWN AND WHITE WIRES ARE USED WITH HEAT KITS ONLY 5 EBTDR HAS A 7 SECOND ON DELAY WHEN G IS ENERGIZED AND A 65 SECOND OFF DELAY WHEN G IS DE ENERGIZED 0140A00058 B Wiring is subject to change Always refer to the wiring diagram on the unit for the most up to date wiring 11
2. oa 05 06 07 ARUF18B14 ARUF24B14 Low High 1145 1085 1020 950 900 845 765 ARUF30B14 Medi 580 345 ARUF36C14 Low ARUF42C14 Low ARUF48D14 Low ARUF60D14 AIRFLOW DATA CFM ARUF 14 Notes Airflow data indicated is at 230V without air filter in place The chart is for information only For satisfactory operation external static pressure must not exceed value shown on rating plate The shaded area indicates ranges in excess of maximum design external static pressure Use the CFM adjustment factors of 0 98 for horizontal left and 0 96 for horizontal right amp downflow orientations 10 WIRING DIAGRAMS HIGH VOLTAGE A warnine ARPT 14 ARUF 14 DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH PLE BK 226 RD Li 12 ONE 1 ELEMENT ROWS Mt R RD ES TWO 2 ELEMENT ROWS C C C Q THREE 3 ELEMENT ROWS FOUR 4 ELEMENT ROWS Lt 12 NOTE WHEN INSTALLING HEATER KIT ENSURE SPEED TAP IS NOT BELOW COMBINATI
3. 24B14 A 30B14 A 36C14 A 42C14 A 48D14 A 60D14 A maose x x x x x x x Hexe x x x x x x x x x x x x x x x x x x x x scosse x x x x x scoe x x x x x x x meaoc x x x x x x x a mene 2011 1 gt lt gt lt gt lt gt lt gt lt gt lt gt x gt lt gt lt gt lt gt lt gt lt gt lt gt lt x gt lt gt lt gt x x gt x gt lt gt lt gt lt gt lt gt lt gt x gt lt gt lt gt x gt lt gt lt gt lt gt lt gt lt x gt lt gt lt gt lt gt lt gt lt gt lt gt lt gt lt gt lt gt gt gt gt gt lt gt lt gt gt gt gt gt lt gt lt gt gt gt gt gt lt gt lt gt lt HKSC20DA HKSC20DB Revision level that may or may not be designated Refer to the minimum airflow requirements for each of the heat kits 1 ARUF HE ATER kW aur 10 15 19 20 25 o 24 75 75 75 2 so 55 vo Ca pom om oes ome 5 51 01 0 om om no vo 010 Las ase oem oem me m 6 ome o e
4. e oem eo ns 176 75 Minimum CFM required for Heater Kits ARPT 14 ARUF 14 PRODUCT DIMENSIONS M3IA 3015 1 MIIA LNOUS 0971 131NI 2 wo A3 NI 450 8769 S 6L 4 8111 3 1IV L3G LYOd 33S 1 1973 Nou ons un LZ NOILV2O1 0901 H3AOO 8 9 2 SF 0 82 6 2 5 wo 425 i61 GL PRODUCT DIMENSIONS ARPT 14 ARUF 14 Dimensions are in inches a s 5 r e Dimensions are in inches PRODUCT SPECIFICATIONS ARPT 14 ARPT ARPT ARPT ARPT ARPT ARPT 30B14 36C14 36D14 42D14 48D14 60D14 ARPT ARPT 18B14 24B14 Nominal Ratings e ing h 18 000 24 000 48 000 60 000 Airflow Rate CFM High 1065 1020 1445 1705 1810 2080 Med 825 775 1300 1485 1555 1865 Low 560 565 1175 1140 1350 1505 o z e 3 3 4 3 4 3 4 11 15 E 11 15 T Width 10 10 Coil Drain Connect 3 4 3 4 Refrigerant Line Connection Size Liquid 2 2 Suction Electrical Data 208 230 208 230 208 230 208 230 208 230 208 230 208 230 208 230 15 15 15 15 15 15 15 15 15 15 197 253 197 253 197 253
5. ARUF36C14 ARUF48D14 ARUF24B14 ARUF42C14 ARUF60D14 ARPT36C14 ARPT36D14 ARP T42D14 ARP T48D14 ARP T60D14 ARUF30B14 ARPT 18B14 ARPT24B14 ARPT30B14 This kit is used to prevent sweating on the vertical drain pan ARPT and ARUF air handlers are multi position multi speed with direct drive motors They are available in 1 1 2 to 5 ton sizes with optional 3 kW to 21kW electric heat kits available for field installation See following note NOTE Factory sealed to achieve a 2 or less leakage rate at 1 0 water gauge external duct static pressure Complies with the Factory sealed Air Handling Credit as listed inthe 2001 Florida Building Code Chapter 13 Section 610 2 A 2 1 HKS HEAT KITS Heat Kit Applications ARPT Te GN vee mote smn ec oes soe X X X x X X x X X X X X X X X ANSCSEXE X X X x x x x gt x HKuXC X x x x gt HK X X x X X X 5 5 X x X X 5 9 HG x x X Hc 1 41 j x x x Revision level that may or may not be designated Refer to the minimum airflow requirements for each of the heat kits Type model 18B14 A
6. 197 253 197 253 197 253 19 19 19 35 3 3 5 4 46 105 155 167 Voltage 95 Min Circuit Ampacity 5 5 6 6 Max Overcurrent Device amps 15 15 Min Max VAC ot x 79 Ship Weight 165 a N Airflow rate 9 3 static PRODUCT SPECIFICATIONS ARUF 14 ARUF ARUF ARUF ARUF ARUF ARUF ARUF 18B14 24B14 30B14 36C14 42C14 48D14 60D14 Cooling Btu h 18 000 24 000 30 000 36 000 42 000 48 000 60 000 Airflow rate CFM High 1045 1020 1385 1465 1810 2125 ds 835 1235 1290 1555 1885 565 980 1000 1350 1455 d Drain Connect FPT Drain Connect FPT LO MN Line aT Size Beam o gt m m L poe Airflow rate 9 3 static BLOWER PERFORMANCE DATA ARPT 14 ARUF 14 Blower Static Pressure in w c Speed 01 02 04 05 06 07 High 1185 1125 1065 1010 985 910 780 ARPT18B14 Medium 900 850 825 785 715 670 610 High 1185 1125 1065 1010 985 910 780 ARPT24B14 Medium 900 850 825 785 715 670 610 High 1145 1085 1020 950 900 845 765 ARPT30B14 ARPT36C14 ARPT36D14 ARPT42D14 ARPT48D14 Low 1895 1340 1280 1220 1150 1090 1020 ARPT60D14 AIRFLOW DATA CFM ARPT 14 Blower Static Pressure in w c Speed 02
7. ON ON THIS UNITS SERIAL PLATE AFTER INST ALLING OPTIONAL HEAT KIT MARK A X IN THE NUMBER OF HEATER ELEMENT ROWS INSTALLED NO MARK INDICATES NO HEAT KIT INSTALLED 5 ELEMENT ROWS DATA SUPPLIED WITH HEATER KIT NIMUM BLOWER SPEED MBS SPECIFIED FOR THE AIR HANDLER HEATER KIT PROVIDED ABOVE MARK ACCORDING TO THE SEE NOTE 2 TERMINAL BLOCK SHOWN L1 L2 FOR 50HZ MODELS ONLY 6 BL GR WH BR EQUIPMENT GROUND USE COPPER WIRE GRD BK RD 7 SR PLF 9 0 PLM 8 SEE NOTE 4 208 240 VOLTS BR WH SEE NOTE 5 SEE NOTE 1 EBTDR 240 COPPER POWER SUPPLY SEE RATING PLATE USE MIN 75 C FIELD WIRE PU SEE NOTE 3 IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE THREE SPEED MOTOR WIRING SELECT MODELS ONLY com RD LOW M2 BL MEDIUM BK HIGH TR 1 PU EBTDR EBTDR 4 24 5 RD WH BR BL GR COLOR CODE WIRING CODE BK_BLACK GR_GREEN FACTORY WIRING RD_ RED PU_ PURPLE HIGH VOLTAGE YL BR_BROWN LOW VOLTAGE BL_ BLUE WH_ WHITE FIELD WIRING HIGH VOLTAGE COMPONENT CODE LOW VOLTAGE
8. TECHNICAL MANUAL ARUF 14 8 ARPT 14 Air Handlers Refer to Service Manual RS6200006 for installation operation amp troubleshooting information All safety information must be followed as provided the Service Manual Refer to the appropriate Parts Catalog for part number information Models listed on page 3 This manual is to be used by qualified professionally trained HVAC technicians only Goodman RT6121003 does not assume any responsibility for property damage or personal injury due to improper April 2012 Service procedures or services performed by an unqualified person p Copyright 2012 Goodman Company L P PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing Please use this number when requesting service or parts information EXPANSION PRODUCT DEVICE TYPE F Flowrater A Air Handler T TXV Expansion Device REFRIGERANT CHARGE 4 R 410A only CABINET FINISH P Painted U Unpainted APPLICATION R Multi Position PSC Motor ELECTRICAL 1 208 230V 1ph 60Hz CABINET WIDTH B 17 5 C 21 D 24 5 NOMINAL CAPACITY RANGE 18 1 1 2 Tons 24 2 Tons 30 2 1 2 Tons 36 3 Tons 42 3 1 2 Tons 48 4 Tons 60 5 Tons All Airhandlers use DIRECT DRIVE MOTORS Power supply is AC 208 230v 60 hz 1 phase HIGH VOLTAGE A WARNING Disconnect ALL power before servicing or installing this uni
9. ations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise contact your local EPA office Do not connect or use any device A WARNING that is not design certified by Goodman for use with this unit Serious property damage personal injury reduced unit performance and or hazardous conditions may result from the use of such non approved devices A WARNING To prevent the risk of property damage personal injury or death do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance When installing or servicing this equipment safety clothing in cluding hand and eye protec tion is strongly advised If installing this equip ment in an area that has special safety require ments hard hats etc observe these requirements To protect the unit when brazing close to the painted surfaces the use of a quenching cloth is strongly advised to prevent scorching or marring of the equipment finish A WARNING The unit MUST have an uninter rupted unbroken electrical ground to minimize the possibility of personal in jury if an electrical fault should occur The electri cal ground circuit may consist of an appropriately sized electrical wire connecting the ground lug in the unit control box to the building electrical ser vice panel Other methods of grounding are per mitted if perfor
10. med in accordance with the National Electric Code NEC American National Standards Institute ANSI National Fire Protection Associa tion NFPA 70 and local state codes In Canada electrical grounding is to be in accordance with the Canadian Electric Code CSA C22 1 Failure to ob serve this warning can result in electrical shock that can cause personal injury or death PRODUCT DESIGN If this appliance is installed in A WARNING an enclosed area such as a garage or utility room with any carbon monoxide CO producing appliance i e automobile furnace water heaters etc ensure the area is properly ventilated A WARNING HIGH VOLTAGE Disconnect ALL power before servicing or installing this unit Mul tiple power sources may be present Failure to do so may cause property damage per sonal injury or death AIR HANDLERS See Air Handler Specification Sheet for Proper Combinations ALL AIR HANDLERS USE DIRECT DRIVE MO TORS POWER SUPPLY IS 208 230 V 60 HZ 1 PHASE Installation Before installing this appliance insure that it is properly sized and adequate power is available This appliance can be installed in the vertical or right horizon tal position without modification The horizontal left and downflow positions require product modification This product is designed for zero inches 0 inches clear ance however adequate access for service or replacement must be considered without removing
11. permanent structure This unit can be installed on a platform when deemed neces sary In an attic installation a secondary drain pan must be pro vided by the installer and placed under the entire unit with a separate drain line properly sloped and terminated in an area visible to the owner This secondary drain pan is required in the event that there is a leak or main drain blockage Closed cell insulation should be applied to the drain lines in uncondi tioned spaces where sweating may occur Appliances installed in garages warehouses or other areas where they may be subjected to mechanical damage must be suitably guarded against such damage by installing be hind protective barriers being elevated or located out of the normal path of vehicles When installed on a base the base must also be protected by similar means Heating and cooling equipment located in garages which may generate a glow spark or flame capable of igniting flam mable vapors must be installed with the ignition source at least 18 46cm above the floor level When more than one appliance is installed in a building it shall be permanently identified as to the area or space ser viced by the equipment When this product is installed in the downflow installation in an unconditioned space remove the horizontal drain pan and install the following insulation kit MODEL LIST FOR DRAIN PAN INSULATION KITS Insulation Kit Insulation Kit Insulation Kit ARUF18B14
12. t Multiple power sources may be present Failure to do so may cause property damage personal injury or death Installation and repair of this unit WARNING should be performed ONLY by in dividuals meeting the require A WARNING Goodman will not be responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you assume responsibility for any personal injury or property damage which may result Many jurisdictions require a license to install or service heating and air conditioning equipment ments of an entry level technician at a minimum as specified by the Air Conditioning Heating and Refrigera tion Institute AHRI Attempting to install or repair this unit without such background may result in product damage personal injury or death PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing Please use this number when requesting service or parts information ARPT18B14 ARPT24B14 ARPT30B14 ARPT36C14 ARPT36D14 ARPT42D14 ARPTA48D14 ARPT60D14 ARUF18B14 ARUF24B14 ARUF30B14 ARUF36C14 ARUF42D14 ARUF48D14 ARUF60D14 A WARNING The United States Environmental Protection Agency EPA has issued various regulations re garding the introduction and disposal of refrigerants introduced into this unit Failure to follow these regul

Download Pdf Manuals

image

Related Search

Related Contents

Muvit MUSLI0610 mobile phone case  Siemens M35 User's Manual  Jasco 17453 Instruction Manual  Samsung BD-J5500 Curved 3D Blu-ray Player  L`association Espoir, Sport, Culture, Insertion Jeunes  一取扱説明書 - ご家庭のお客さま/大阪ガス  4 - SEW-Eurodrive  Xerox 50 LP/ST User's Manual  Tran:3512 DSU/CSU User`s Manual:AppC:Worksheets  Sharp LC-42XD1EA 42" Full HD Black LCD TV  