Agilent M9216A PXI High Voltage Data Acquisition
Contents
1. Multiplexer Se SSS ee eS See Channel 1 e k p amp Filter pre se ka Aux11 T m0 mef Auxi2 9 wn wn eee nnmnnn Z 10 x 18 26 Aw21 8 os bh a a Oe te ee ee ee eee St ees Aux22 ee et et ee 1 jet pa Lia 2 is e amp g L z ej iw wa T te T a Ta Sa i 20 3x lets Dae p L Aux41 ST OTT Moed Lnn of Aux42 a Filter pre amp Figure 8 M9216A in Multiple Channel Measurement Mode 19 Agilent M9216A PXI High Voltage Data Acquisition 20 Step A The M9216A should already be in Multiple Channel Measurement Mode when started up if not please set the measurement mode to Multiple Channel Note that a hardware reset will occur when switching the measurement mode By default all input ports will be configured with a Record Size of 5000 points and the recording from both the 5 V and 100 V waveforms will be available Agilent M9216A DAQ Module DAR File View Utility Tools Help Set Measurement Mode Status Monitoring Measure Mode Multiple Channel 1 2 Connected Port 1 10 pa Trigger Mode Immediate Measure Range B B A Acquisition Status Select Port for Acquisition Get Acquisition Status v Channel Legend Input Connector 2 F Measure Range Aquisition Status m L Low Range 1 Idle Measure Range Both v H High Range B Busy 3 B Both Range C Completed Input Port N None T TimeOut Port Config
2. Microsoft Internet Explorer 7 or greater Windows 7 32 bit and 64 bit Starter Home Basic Home Premium Professional Ultimate or Enterprise 1 GHz 32 bit x86 or 1 GHz 64 bit x64 Itanium 64 is not supported 1 GB minimum 1 5 GB available hard disk space includes 1GB for Microsoft NET Framework 2 0 SP2 2 65 MB for Agilent I0 Libraries Suite Support for DirectX 9 graphics with 128 MB graphics memory recommended Super VGA graphics is supported Microsoft Internet Explorer 7 or greater A cPCI PXI 1 or PXIh chassis peripheral slot The Agilent M9018A chassis is recommended A PXI or PXle remote or embedded controller An Agilent M9045A ExpressCard interface for portable laptops or Agilent M9047A PCle interface for desktop PCs or equivalent PXI or PXle remote controllers running one of the above operating systems M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition Table 1 Minimum system requirements continued Embedded controller An Agilent M9021A System Interface Card or equivalent embedded controller running one of the above operating systems Note The embedded controller must be compatible with the Agilent M9018A chassis Softwares Agilent 10 Libraries Suite 16 0 and above is required Adobe Reader version 6 0 or higher is required to view the provided PDF files 1 Because of the installation procedures less memory may be required
3. or refer to the Support information on the product web page at http www agilent com find M9216A Write the following information on a tag and attach it to the malfunctioning equipment e Name and address of owner A P O box is not acceptable as a return address e Product model number for example M9216A e Product serial number for example MYXXXXXXXX The serial number label is located on the side panel of the module The serial number can also be read from the Soft Front Panel interface but only after the software is installed e Description of failure or service required Carefully pack the module in its original ESD bag and packing carton If the original carton is not available use bubble wrap or packing peanuts and place the instrument in a sealed container and mark the container FRAGILE On the shipping label write ATTENTION REPAIR DEPARTMENT and the RMA number If any correspondence is required refer to the product by its serial number and model number M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition Step 2 Verify the Shipment Contents The following items are included in the M9216A shipment e M9216A PXI High Voltage Data Acquisition Software and Product Information CD ROM M9216 10001 contains software drivers and all product documentation in PDF format e Printed copy of this document M9216A Startup Guide e Calibration certificate Every PXI modul
4. M9216A Check the manual revision on the first page of each manual e Startup Guide This manual Printed copy for outdoor use included with shipment e Agilent M9216A PXI High Voltage Data Acquisition Device Drivers and Help Available for IVI C and IVI COM and LabVIEW G drivers e Agilent M9216A PXI High Voltage Data Acquisition Soft Front Panel Software and Help e Agilent M9216A PXI High Voltage Data Acquisition Data Sheet Agilent M9216A PXI High Voltage Data Acquisition Step 1 Unpack and Inspect the Module CAUTION The M9216A is shipped in materials which prevent damage from static The module should only be removed from the packaging in an anti static area after ensuring that correct anti static precautions are taken Store all modules in anti static envelopes when not in use ESD precaution Electrostatic discharge ESD can damage or destroy electronic components All work on electronic assemblies should be performed at a static safe work station The following figure shows an example of a static safe work station using two types of ESD protection Building Ground 1 Meg Ohm Resistor Building Ground 1 Meg Ohm Resistor Floor Mat Figure 1 Static safe work station example 2 M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition Purchase acceptable ESD accessories from your local supplier e Conductive table mat and wrist strap combination e Conductive floor ma
5. for the operation than is required for the installation 2 NET Framework Runtime Components are installed by default with Windows Vista and Windows 7 Therefore you may not need this amount of available disk space M9216A Startup Guide 7 Agilent M9216A PXI High Voltage Data Acquisition Power up the controller If you are using a remote controller power up the host computer If you are using an embedded controller complete the following steps 1 Install the embedded controller module into a compatible chassis Recommended Agilent M9018A 18 slot PXIe Chassis 2 Connect your I O peripherals mouse keyboard and monitor 3 Power up the chassis Install the softwares The M9216A softwares are located on the bundled CD M9216 10001 The same softwares are also available for free download at the Agilent website http www agilent com find M9216A This installation includes the following e Agilent IO Library Suite IOLS which includes the Agilent Connection Expert e Soft Front Panel SFP device drivers IVI C and IVI COM and LabVIEW G and related user documentation for the M9216A Each PXI module has its own device driver IVI C and IVI COM and LabVIEW G and soft front panel SFP software 1 From the CD browser launch the installer 2 Follow the installer prompts to install all software and documentation for the M9216A PXI High Voltage Data Acquisition 8 M9216A Startup Guide M9216A Startup
6. resistance between the input ports and auxiliary ports For example if input port 18 of Channel 2 was switched to the auxiliary output port Aux21 input port 2 will automatically be switched to the complementary auxiliary port Aux22 25 Agilent M9216A PXI High Voltage Data Acquisition 26 M9216A Startup Guide www agilent com Contact us To obtain service warranty or technical assis tance contact us at the following phone or fax numbers United States tel 800 829 4444 fax 800 829 4433 Canada tel 877 894 4414 fax 800 746 4866 China tel 800 810 0189 fax 800 820 2816 Europe tel 31 20 547 2111 Japan tel 81 426 56 7832 fax 81 426 56 7840 Korea tel 080 7690800 fax 080 769 0900 Latin America tel 305 269 7500 Taiwan tel 0800 047 866 fax 0800 286 331 Other Asia Pacific Countries tel 65 6375 8100 fax 65 6755 0042 Or visit Agilent World Wide Web at http www agilent com find assist Product specifications and descriptions in this document are subject to change without notice Always refer to the Agilent website for the latest revision Agilent Technologies Inc 2011 First Edition June 1 2011 M9216 90001 Agilent Technologies
7. 87 or DFAR 252 227 7015 b 2 November 1995 as applicable in any technical data Safety Notices CAUTION A CAUTION notice denotes a haz ard It calls attention to an operat ing procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly per formed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated condi tions are fully understood and met The following safety precautions should be observed before using this product and any associated instrumentation This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury Read and follow all installation operation and main tenance information carefully before using the product Refer to the user documenta tion for complete product specifications M9216A Startup Guide If this product is not used as spec ified the protection provided by the equipment could be impaired This product must be used ina normal condition in which all means for protection are intact only The types of produ
8. Agilent M9216A PXI High Voltage Data Acquisition Startup Guide 2 Agilent Technologies Notices Agilent Technologies Inc 2011 No part of this manual may be reproduced in any form or by any means including elec tronic storage and retrieval or translation into a foreign language without prior agree ment and written consent from Agilent Technologies Inc as governed by United States and international copyright laws Manual Part Number M9216 90001 Edition First Edition June 1 2011 Agilent Technologies Inc 5301 Stevens Creek Blvd Santa Clara CA 95051 USA Sales and Technical Support To contact Agilent for sales and technical support refer to the support links on the following Agilent web resources wwwaagilent com find M9186A product specific information and support software and documentation updates www agilent com find assist worldwide contact information for repair and service Information on preventing damage to your Agilent equipment can be found at www agilent com find tips Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accor dance with the terms of such license Warranty The material contained in this docu ment is provided as is and is sub ject to being changed without notice in future editions Further to the max imum extent permitted by applicable law Agi
9. Guide Agilent M9216A PXI High Voltage Data Acquisition Agilent M9216 InstallShield Wizard The InstallShield Wizard will install Agilent M9216 on your computer To continue click Next The InstallShield Wizard will install Agilent M9216 on your computer To continue click Next Cancel Figure 2 InstallShield Wizard for Agilent M9216A 3 After installation is complete power down the chassis and the host PC if using the remote controller Agilent M9216A PXI High Voltage Data Acquisition Step 4 Install the Module CAUTION The PXI hardware does not support hot swapping capabilities changing modules while power is applied to the chassis Before installing the M9216A into the chassis ensure that the chassis is powered off and unplugged to prevent damage to the module 0 10 The M9216A module can be used in a chassis with a cPCI PXI 1 or PXIh chassis peripheral slot The module can be installed in any standard PXI slot marked with a peripheral slot compatibility image a circle containing the slot number The module can also be installed in any hybrid PXI slot marked with a peripheral slot compatibility image the letter H and a solid circle containing the slot number Ensure that the chassis power switch is at the Off Standby position before you unplug the PXI chassis If the chassis has multiple fan speed settings ensure that the fans are set to automatic Do not set the fan sp
10. able per channel The operation of the input multiplexer is described in the section Using the Auxiliary Output Ports in Chapter One of the M9216A Service Manual Figure 11 which is reproduced from the Service Manual shows the input multiplexer diagram for Bank 1 Table 2 shows the relationship between the primary and complementary auxiliary output ports For example when you switch input port 9 to Primary Auxiliary Port input port 25 will be connected to the Complementary Auxiliary Port M9216A Startup Guide M9216A Startup Guide Aux22 Aux21 Agilent M9216A PXI High Voltage Data Acquisition gt Digtizerl y Digter Figure 11 Input Port Multiplexer for Bank 1 Table 2 Connection logic of Bank 1 Channel 1 Aux11 Primary Aux12 Complementary Always Connected Port 1 Port 17 Port 9 Port 25 Port 17 Port 1 Port 25 Port 9 Channel 1 Aux21 Primary Aux22 Complementary Always Connected Port 2 Port 18 Port 10 Port 26 Port 18 Port 2 Port 26 Port 10 23 Agilent M9216A PXI High Voltage Data Acquisition 24 Step A As in Verifying the Digitizer Channels set the M9216A Multiple Channel measurement mode However no waveform acquisition will be initiated during this verification Step B In this example we will verify that the input ports of Channel 2 are able to be switched to the auxiliary output ports To route the input ports to auxiliary output tick
11. any unknown circuit before measuring Operators of this product must be protected from electric shock at all times The respon sible body must ensure that operators are prevented access and or insulated from every connection point In some cases con nections must be exposed to potential human contact Product operators in these circumstances must be trained to protect themselves from the risk of electric shock Before operating an instrument ensure that the line cord is connected to a prop erly grounded power receptacle Inspect the connecting cables test leads and jumpers for possible wear cracks or breaks before each use When installing equipment where access to the main power cord is restricted such as rack mounting a separate main input power disconnect device must be provided in closed proximity to the equipment and within easy reach of the operator For maximum safety do not touch the prod uct test cables or any other instruments while power is applied to the circuit under test ALWAYS remove power from the entire test system and discharge any capacitors before connecting or disconnecting cables or jumpers installing or removing switching cards or making internal changes such as installing or removing jumpers Do not touch any object that could provide a current path to the common side of the cir cuit under test or power line earth ground Always make measurements with dry hands while standing
12. ct users are Responsible body is the individual or group responsible for the use and main tenance of equipment for ensuring that the equipment is operated within its specifications and operating limits and for ensuring that operators are ade quately trained Operators use the product for its intended function They must be trained in electrical safety procedures and proper use of the instrument They must be protected from electric shock and contact with hazardous live circuits Maintenance personnel perform rou tine procedures on the product to keep it operating properly for example set ting the line voltage or replacing con sumable materials Maintenance procedures are described in the user documentation The procedures explic itly state if the operator may perform them Otherwise they should be per formed only by service personnel Service personnel are trained to work on live circuits perform safe installa tions and repair products Only properly trained service personnel may perform installation and service procedures Exercise extreme caution when a shock hazard is present Lethal voltage may be present on cable connector jacks or test fix tures The American National Standards Institute ANSI states that a shock hazard exists when voltage levels greater than 30V RMS 42 4V peak or 60VDC are present M9216A Startup Guide A good safety practice is to expect that haz ardous voltage is present in
13. e is shipped with a Software and Product Information CD ROM The M9216A CD1 option provides the M9216A Software and Product Information CD ROM M9216 10001 All of the files contained on the CD are available for free download at the Agilent website at http www agilent com find M9216A M9216A Startup Guide 5 Agilent M9216A PXI High Voltage Data Acquisition Step 3 Install the Software System requirements Table 1 Minimum system requirements Operating systems Processor speed Available memory Available disk spacel Video Browser Chassis Interface controller Remote controller Windows XP SP3 or later 32 bit Home or Professional 600 MHz or higher required 800 MHz recommended 256 MB minimum 1 GB or more recommended 1 5 GB available hard disk space includes 1GB for Microsoft NET Framework 2 0 SP2 2 65 MB for Agilent I0 Libraries Suite Super VGA 800 x 600 256 colors or more Microsoft Internet Explorer 6 0 or greater Windows Vista SP1 and SP2 or later 32 bit and 64 bit Home Basic Home Premium Business Ultimate or Enterprise 1 GHz 32 bit x86 or 1 GHz 64 bit x64 Itanium 64 is not supported 1 GB minimum 1 5 GB available hard disk space includes 1 GB for Microsoft NET Framework 2 0 SP2 2 65 MB for Agilent I0 Libraries Suite Support for DirectX 9 graphics with 128 MB graphics memory recommended Super VGA graphics is supported
14. eed to low or turn it off Position the chassis so that there is ample space between the chassis fan intake and exhaust vents Blockage by walls or obstructions affects the air flow needed for cooling Refer to the chassis documentation for more information about cooling If you are using an embedded controller proceed to step 5 If you using a remote controller skip to step 6 M9216A Startup Guide M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition Figure 3 Installing the module to the chassis 5 Hold the module by the injector ejector handle and slide it into an available PXI or hybrid slot as shown in Figure 3 e Install the module into the PXI slot of the chassis by placing the module card edges into the front module guides top and bottom e Slide the module to the rear of the chassis and assure that the injector ejector handle is pushed down in the unlatched downward position e Slide the module completely into the chassis e When you begin to feel resistance push up on the injector ejector handle to fully inject the module into the chassis If you are using a remote controller install the System Interface Card in the chassis Latch the module by pulling up on the injector ejector handle and secure the front panel to the chassis using the module front panel mounting screws Tighten the screws on the module or remote controller front panel Performance may suffer if the
15. enu and view the information of the M9216A You will be able to see something similar to Figure 6 Agilent M9216A DAQ Module File View Utility Tools Help Set Measurement Mode Measure Mode Multiple Trigger Mode Channel eB Select Port for Acquisition Channel 1 Input Connector 4 v Soft Front Panel Version 1 0 0 0 Instrument Information Serial Number 1 0 0 0 Driver Revision 1 0 Instrument Model M9216A Hardware Revision Sim1 0 0 0 Figure 6 SFP main tab 16 Status Monitoring Channel 1 Connected Port 1 B Measure Range Acquisition Status C EJ Get Acquisition Status M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition Functional verification optional Requirements The M9216A High Voltage DAQ digitizer channels are functionally verified by setting a DC voltage at the input port and measuring the voltage with the SFP The input multiplexer is verified by measuring the resistance between the input and auxiliary ports with a multimeter These procedures will verify whether the connectors relays of the input multiplexer and digitizers of the M9216A are functioning properly The SFP will be used to manually control the M9216A Required hardware To perform functional verification of the digitizer channel a stable DC source preferably with low noise is required A multimeter can also be used to provide a second verification of the voltage I
16. f you intend to verify that the M9216A meets accuracy specification a DC reference source will be required Refer to the M9216A Service Manual for steps to perform DC accuracy verification To have easy access to the pins and prevent mechanical damage to the connector pins we recommend that cables terminal blocks or connector savers be used during the verification Figure 7 shows the front panel layout and port labels for both the input and auxiliary out connectors The M9216A is capable of measuring voltages of up to 100 V Due to safety concerns Agilent does not recommend that high voltages be used for functional verification unless appropriate safety concerns are taken M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition la S O Paa eos OOCOCOCOOCOOOO ECOOCOOCOO0OOGO Figure 7 M9216A front panel layout of the input and auxiliary ports M9216A Startup Guide M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition Verifying the digitizer channels The following steps will verify that the M9216A digitizer channels are functional and are able to acquire waveforms You may repeat the steps outlined below to verify all eight digitizer channels in the M9216A For verification purpose the M9216A will be used in Multiple Channel Measurement Mode The block diagram of the M9216A in Multiple Channel Mode is reproduced from the M9216A Service Manual and shown in Figure 8
17. l an Agilent office for information No operator serviceable parts inside Refer servicing to qualified personnel To prevent electrical shock do not remove covers Front and Rear Panels Symbols The CE mark is a registered trade mark of the European Community The C Tick mark is a registered trademark of the Australian Spec mnie trum Management Agency ICES NMB 001 This symbol indicates ISM GRP 1CLASS A Product compliance with the Canadian Interfer ence Causing Equipment Standard ICES 001 It also identifies the product is an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 4 The CSA mark is a registered Ge trademark of the CSA Interna tional This symbol indicates separate pzd collection for electrical and elec wee tronic equipment mandated under EU law as of August 13 2005 All electric and electronic equipment are required to be separated from normal waste for disposal Reference WEEE Direc tive 2002 96 EC Fery This symbol indicates the time 109 period during which no hazardous or toxic substance elements are expected to leak or deteriorate during nor mal use Forty years is the expected useful life of the product Cleaning Precautions To prevent electrical shock dis connect the Agilent Technologies instrument from mains before cleaning Use a dry cloth or one slightly dampened with water to clean the external case parts Do not attempt to clean internal
18. lent disclaims all warranties either express or implied with regard to this manual and any information contained herein including but not limited to the implied warranties of merchantability and fitness for a par ticular purpose Agilent shall not be liable for errors or for incidental or consequential damages in connec tion with the furnishing use or per formance of this document or of any information contained herein Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms the warranty terms in the sep arate agreement shall control Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcon tract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995 or asa commercial item as defined in FAR 2 101 a or as Restricted computer soft ware as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication or disclo sure of Software is subject to Agilent Tech nologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will receive no greater than Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Government users will receive no greater than Limited Rights as defined in FAR 52 227 14 June 19
19. ly To clean the connectors use alcohol in a well ventilated area Allow all residual alcohol moisture to evaporate and the fumes to dissi pate prior to energizing the instru ment M9216A Startup Guide Contents Introduction 1 Related documentation 1 Step 1 Unpack and Inspect the Module 2 ESD precaution 2 Inspect the module fordamage 3 Return the module for service 4 Step 2 Verify the Shipment Contents 5 Step 3 Install the Software 6 System requirements 6 Power up the controller 8 Install the softwares 8 Step 4 Install the Module 10 Step 5 Verify the Operation of the M9216A Module 14 Functional verification optional 17 M9216A Startup Guide VI M9216A Startup Guide Introduction Agilent M9216A PXI High Voltage Data Acquisition The scope of this Startup Guide is to detail the processes of receiving and setting up the Agilent M9216A PXI High Voltage Data Acquisition installing the required software and verifying basic module operation If you have any questions after reviewing this information please contact your local Agilent Technologies Inc representative or contact us through our website at http www agilent com find M9216A Related documentation M9216A Startup Guide A softcopy of this Startup Guide and the documentation listed below can be found on the CD ROM that is shipped with this product You can also download them for free through our website at http www agilent com find
20. nnector number for any input port Chart Display a CHANNEL 1 CHANNEL 2 CHANNEL3 CHANNEL4 CHANNELS CHANNEL6 CHANNEL7 CHANNEL 8 Average 1 000 Low Range 2000 2500 3000 3500 4000 4500 5000 Sample Count High Range 2000 2500 3000 3500 4000 4500 5000 Sample Count Figure 10 Waveform capture display 21 Agilent M9216A PXI High Voltage Data Acquisition 22 Step C Press Initiate Capture Check the status of the acquisition for the channel under test in the Status Monitoring section of the SFP When the acquisition is completed for all channels bring up the waveform display window by pressing Show Chart Select the tab for the channel under verification and press FetchWaveformReal The recorded waveform of the DC signal will be displayed for both the 5 V and 100 V sub channel The mean voltage is also shown at the top left corner of each waveform display Confirm that the displayed mean voltage is sufficiently close to the expected voltage Compare the measured value to the voltage measured with a multimeter Repeat steps A and B to verify the input ports for all channels Verifying the auxiliary output ports To verify that the M9216A multiplexer is functioning the input ports are switched to the auxiliary output ports The resistance between the input port and auxiliary ports are then measured with a multimeter to check connectivity Note that there are two auxiliary ports avail
21. on a dry insulated surface capable of withstanding the voltage being measured The instrument and accessories must be used in accordance with its specifications and operating instructions or the safety of the equipment may be impaired CAUTION Do not exceed the maximum signal levels of the instruments and accessories as defined in the specifications and operating information and as shown on the instrument or test fixture panels or switching card Chassis connections must only be used as shield connections for measuring circuits NOT as safety earth ground connections If you are using a test fixture keep the lid closed while power is applied to the device under test Safe operation requires the use of a lid interlock Instrumentation and accessories shall not be connected to humans To maintain protection from electric shock and fire replacement components in mains circuits including the power transformer test leads and input jacks must be pur chased from Agilent Standard fuses with applicable national safety approvals may be used if the rating and type are the same Other components that are not safety related may be purchased from other suppliers as long as they are equivalent to the original component note that selected parts should be purchased only through Agi lent to maintain accuracy and functionality of the product If you are unsure about the applicability of a replacement component cal
22. r by clicking Start gt All Programs gt Agilent 10 Library Suite gt Agilent Connection Expert The ACE will display all modules that are connected and installed Review the configuration data and launch the M9216A Soft Front Panel SFP The M9216A SFP will provide control over the module for operational verification procedures x Connect to Instrument Select Instrument Modules Simulation Mode I M9216A PXI2 10 0 INSTR Selected Instrument PX12 10 0 INSTR Figure 5 Connect to Instrument dialog box 14 M9216A Startup Guide M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition If the M9216A does not show up on the instrument list e Verify the M9216A is correctly installed in the mainframe e If using an external host PC and PCI bus extender system verify that the mainframe power is turned on Ensure that the mainframe is powered on before the PC controller See the mainframe user s manual for additional information e Check that the bus extender card residing in the host computer is plugged in properly Agilent M9216A PXI High Voltage Data Acquisition Connectivity verification 1 Launch the SFP software For full descriptions and details on how to use the SFP please refer to the Agilent M9216A Soft Front Panel Help document When successful the M9216A SFP dialog box will appear By default the M9216A will be started in Multiple Channel Mode Click on the Help gt About m
23. screws are not tightened properly Verify that the PXI chassis fans are operable and free of dust and other contaminants that may restrict airflow Agilent M9216A PXI High Voltage Data Acquisition 10 Install all chassis covers and filler panels after installing the module Missing filler panels may disrupt necessary air circulation in the chassis 11 If you are using a remote controller connect the System Interface Card in the chassis to host computer 12 Plug in and power up the PXI chassis 13 If you are using a remote controller reboot the host PC WARNING Tighten the screws on the module front panel Protection provided by the equipment could be impaired if the screws are not tightened properly 12 M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition Module installation procedures 1 Press down the ejector 2 Slide the M9216A module into any slot until the backplane connectors touch 3 Seat the M9216A module into the mainframe by pulling up the ejector 4 Tighten the top and bottom screws to secure the M9216A module to the mainframe Figure 4 Module installation procedures M9216A Startup Guide 13 Agilent M9216A PXI High Voltage Data Acquisition Step 5 Verify the Operation of the M9216A Module The intention of this step is to verify the basic operations of the newly installed module Run the Agilent Connection Expert ACE by clicking its desktop shortcut icon o
24. t and heel strap combination Both types when used together provide a significant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate ESD protection when used alone To ensure user safety the static safe accessories must provide at least 1 of isolation from ground These techniques for a static safe work station should not be used when working on circuitry with a voltage potential greater than 500 V Inspect the module for damage CAUTION After unpacking the M9216A carefully inspect the unit for any shipping damage Report any damage to the shipping agent immediately as such damage is not covered by the warranty warranty information can be found at the beginning of this manual To avoid damage when handling a module do not touch exposed connector pins M9216A Startup Guide Information on preventing damage to your Agilent equipment can be found at http www agilent com find tips Agilent M9216A PXI High Voltage Data Acquisition Return the module for service Should it become necessary to return the M9216A for repair or service follow the steps below 1 Review the warranty information shipped with your product Contact Agilent to obtain a Return Material Authorization RMA and return address If you need assistance finding Agilent s contact information go to http www agilent com find assist worldwide contact information for repair and service
25. the check box Bank 2 Aux Out in the Auxiliary Settings To select a port select Channel 2 and input connector number in the Select Port for Acquisition section in the SFP Press Update Hardware to ensure that the relays in the M9216A are switched into position Figure 12 shows the SFP dialog window where input port 18 of Channel 2 is switched to auxiliary out M9216A Startup Guide M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition t Agilent M9216A DAQ Module TER File View Utility Tools Help Set Measurement Mode Status Monitoring Measure Mode Multiple Channel 1 _ semam Connected Port Trigger Mode Channel Measure Range Select Port for Acquisition Acquisition Status Channel O S Get Acquisition Status Input Connector Legend R Measure Range Aquisition Status senate O L Low Range 1 Idle Input Port H High Range B Busy B Both Range G2 Completed Port Configuration N None T TimeOut Record Size 5000 Auxitiary Settings Bank 1 Aux Out Bank 2 Aux Out Hysteresis 0 0001 1s Bank 3 Aux Out Slope 3 Positive Bank 4 Aux Out Trigger Level 1 000 Hold Off Count 1 Update Hardware Pre Trigger Sample 0 Initiate Capture Delay 0 FetchWaveformReal TimeOut 1 FetchWaveformint Show Chart Figure 12 Setting the auxiliary output ports Step C Use a multimeter to measure the
26. uration Auxiliary Settings C Bank 1 Aux Out C Bank 2 Aux Out C Bank 3 Aux Out Cl Bank 4 Aux Out ae Connected PXI2 10 0 INSTR No Error Record Size o0 lt Trigger Level 0 0900 L ia ady lt Hysteresis 0 0001 a Slope Positive Hold Off Count w gt wn gt Pre Trigger Sample ar a gt ab aD Delay Figure 9 Setting the M9216A for Multiple Channel acquisition M9216A Startup Guide M9216A Startup Guide Agilent M9216A PXI High Voltage Data Acquisition Step B Set the DC voltage source to 1 0 V or any suitable voltage Connect the DC source to the input port and channel under test either manually or via an external multiplexer Select the input port and digitizer channel using the SFP dialog window Press Update Hardware to ensure that the input port selection and configuration are updated to the M9216A hardware Note that the relays of the M9216A input port multiplexer require about 1 millisecond to settle After steps A and B the SFP dialog should look similar to Figure 9 In Figure 9 Input Port 10 Input Connector 2 of Channel 2 has been configured and selected for acquisition The SFP uses the nput Connector number to select the physical input port In this scheme each of the eight channels has four logical input connectors which is numbered 1 to 4 from top to bottom Use Figure 8 to help locate the corresponding input co