Home
5930 Brochure
Contents
1. KU_OTA Universal Centrifuge 3 types of biohazard proof rotor available High centrifugal force swinging bucket rotor compatible RS 3020M 3 430 3 200 xg Conforms to International Safety Standard IEC61010 2 020 m 7 rotor types available to fit your needs e 4 typesof buckets available for the RS 3020M swinging bucket rotor e High centrifugal force RS 3020M rotor 3 420 xg usable with sealing caps for centrifugal separation of acid fast bacteria e PT 745MS plate rotor up to 3 100 xg with shield covers that prevent contamination m Sample balance can be measured by eye for rotors used at 5 000rpm or less m Streamline routine work with convenient functions for easy operation e Memory flashing function for easy spin down patented automatically memorizes the duration of spin down operations ranging from 1 to 90 seconds The last flashing operation 1 90sec is automatically memorized and easily recalled simply by pressing the Flashing key e 5 available memory settings with one touch save and recall operation e Operation according to centrifugal force g aswell as stepped centrifuging and integral centrifuging g sec settings e Timer can be set up to 990 min sec When on hold the elapsed time is displayed e Optional foot switch enables hands free lid opening m Conforms to International Safety Standard IEC61010 2 020 except when RA 410M 3 rotor is used e in the event of breakage all fragments
2. will be safely retained inside the centrifuge unit e Lid lock mechanism indudes interlock and twin lock hook system right and left e interlocking parts are protected against mechanical impact and employ a two stage electrical protection circuit e Various sensors immediately detect the onset of any trouble during operation m Tachometer port complies with GMP e Easy verification of spinning state m Sample temperature is maintained at 4 C at maximum speed of rotation of all rotors at 25 C ambient temperature e Variable acceleration and deceleration function e Acceleration and deceleration curves are adjustable to best fit your samples and goals Initial acceleration and deceleration speeds can be adjusted to accommodate easily perturbed samples Density gradient centrifugation is also enabled Speed Speed c characteristic switching rotation Slow SI Rapid Super slow Rapid Ne ow Super slow Acceleration deceleration characteristics e Super slow acceleration or deceleration is available for centrifugation of especially sensitive samples to avoid resuspension e Suitable for centrifugation of easily resuspended samples density gradient methods and for blood cell cleaning e The rotational speed N when the acceleration deceleration profile changes can be Set enabling super slow acceleration and deceleration for especially sensitive samples RCF Inte
3. cting tube t5mLn 2 12 17 2 x 72 110 105 053 5310 055 0900 80 64 x 15mL 15 17 2 x 76 110 105 053 5310 055 5850 15mL 15 17 2 x 75 135 125 16 x 15 50mL aa 0 1 053 5310 055 5860 48 x 15mL Conical tube 17x 121 121 053 5310 055 4660 24 x 50mL Conical tube 30 x 117 117 053 5310 055 4610 8 x 100mL 38 46 5 x 75 120 116 3 300 055 5870 4 x 250mL 60 61 8 x 100 141 136 3 300 2 280 053 5310 055 6880 4 x 350mL 65 71 x 100 130 122 3 300 2 280 053 5310 055 6890 12x 16x20x Self standing sputum tube 0 5 Cap diam 42 9 39 931 3 800 gs 053 5310 05 RS 3012M 72 x 15mL 15 17 2 x 75 110 3 300 2 280 053 5180 055 0210 16 x 50mL 27 36 8 x 79 114 3 300 2 280 053 5180 055 0240 48 x 15mL Conical tube 055 0220 16 x 50mL Conical tube 30 x 117 3 300 2 280 053 5180 055 0230 4 x 250mL 60 61 8 x 100 141 3 300 2 280 053 5180 055 4490 4 x 350mL 65 71 x 100 130 3 300 2 280 053 5180 055 5880 4 x 500mL Conical tube 16 96 x 147 3 300 2 280 053 5180 431124 06 4 x 650mL 98 x 136 053 5180 4 x 650mL 84 86 x 100 125 053 5180 055 5890 4 x 750mL 95 97 5 x 100 135 053 5180 en 1 88 W x 134 D x 50 H 3 300 4 x Deep well plates 07 oO ap JE 92 W x 133 D x 36 H 2 000 770 ni 053 5170 02300 x Tissue culture plates 07 76 x 15mL 15 17 2 x 83 116 3 200 pi Equipped with rotor 055 0340 48 x 15mL Conical tube ll 3 400 pi Equipped with rotor 055 0300 16 x 50mL 27 35 8 x 93 117 3 310 1 Equipped with rotor 055 0330 RS 3020M 3 20 x 50mL Conical tube SO 7y Eguipped w
4. es This economical multipurpose fixed angle rotor accepts 12mL or 50mL tubes RA 410M3 Fixed angle rotor 50 15mL x 8 conical tubes This multipurpose fixed angle rotor accepts12mL or 50mL tubes Specifications Model 5930 Maximum Speed e 8 500 rpm Maximum RCF e 9 690 xg Maximum capacity e 3 000 mL Control system e Microprocessor control brushless motor Speed RCF g Time Temperature Acceleration and Deceleration 5 memory banks Alarm display e Lid open Imbalance Over speed Rotor setting condition Abnormally high temperature Detected electrical abnormality in motor inverter lid interlock speed sensor and temperature sensor Acceleration Deceleration e Three selectable rates Rapid Slow and Super Slow Speed setting e From 200 to 8 500 rpm 10 or 100 rpm increments Speed indication e Digital display from 0 to 8 900 rpm 10 rpm increments RCF setting e From 10 to 9 690 xg 10 or 100 xg increments RCF indication e Digital display from 0 to 10 620 xg 10 g increments Integrator setting and indication e Digital display from 1 00 9 99 x10 g sec Single step centrifugation e speed RCF g time temperature acceleration and deceleration 1 memory bank Timer setting and indication e Digital display with HOLD function continuous operation and electric buzzer 1 second to 100 seconds 1 sec increments 100 seconds to 990 seconds 10 sec increments 1 minute to 100 minutes 1 min increments 100 minutes to 990 minutes 10
5. grator function g sec value Identical applications of total centrifugal force are easily reproducible using the g sec function The integrator function enables identical Standard mode centrifugal effects to be applied RS 3012M i Code No 053 5180 Code No 053 5220 swinging bucket rotor Maximum capacity is 750mLx4 8 micro plates and 4 deep well As shown the rotor is fitted with bottles Various tube racks can be plates can be set This bucket has optional shield covers No 027 9210 used no center bar so plates can be A secure clip system lets you easily easily removed attach and remove the shield covers Code No 053 5170 RS 3020M gt 8 micro plates and 8 tissue culture swinging bucket rotor plates can be set As shown the rotor is fitted with optional sealing caps No 027 9300 Universal Refrigerated Centrifuge 5930 Rotor Bucket Tube Rack Table for Model 5930 Rotor Name Nominal Capacity Tube size mm diam x length Bucket Code No Maximum Speed Maximum RCF rpm xg Code No Tube Rack Adaptor Swinging bucket rotor 140 x 6mL RIA tube 10 12 3 x 65 100 95 053 5310 055 5830 80 x 5 7 mL blood collecting tube 0 2 12 13 3 x 63 110 105 053 5310 055 5000 100 x 10mL 12 14 2 x 76 110 105 053 5310 055 5840 80 64 x 5 10mL blood colle
6. ith rotor 055 0310 08 4 x 500mL Conical tube 16 96 x 147 Equipped with rotor 431124 06 4 x 650mL 98 x 136 Equipped with rotor 4 750m Plate rotor PT 21M m 86 W x 130 D x 62 H 3 100 Equipped with rotor PT 89M i ee ni 86 W x 130 D x 89 H 1 080 Equipped with rotor 055 6370 09 PT 745MS ues MICO Rie 86 W x 128 D x 90 H 3 100 Equipped with rotor 055 6380 09 4 x Deep well plates Fixed Angle rotor AT 508C angle rotor is a tool less rotor Tube size mm Nominal Capacity diam x length rom Maximum Speed Maximum RCF Maximum Speed Maximum RCF LOM Bucket Code No xg rom xg Adaptor Code No 8 x 12mL plastic g 10 8 500 9 370 055 1120 8 x 14mL 11 17 x 100 055 0550 8 x 15mL Conical tubes 17 x 121 055 1280 8 x 50mL plastic 012 26 4 28 8 x 98 115 055 1110 8 x 50mL Conical tubes 8 500 9 690 Vivaspin 2 16 7 x 129 6 000 5 270 8 500 9 530 055 1280 Sartorius Vivaspin 6 16 7 x 129 6 000 8 500 9 530 055 1280 Vivaspin 20 8 500 9 690 Milligore Amicon Ultra 4 17 x 129 6 000 8 500 9 530 055 1280 Amicon Ultra 15 30 x 121 6 000 5 350 8 500 9 690 O 1 For centrifugal force indications please refer to the instruction manual 2 Blood collecting tubes made by SEKISUI Insepack II Termo Venoject II Nipro Neotube or Beckton Dickinson Vacutenar can be used Tubes for flow cytometry can also be used 3 Figures in pare
7. ll comes out of the equipment turn off the power switch pull out the power cable plug from eYou receive a minor electrification when you touch the the plug socket and be sure to contact your nearest Kubota equipment body by a naked hand Dealer or an office of Kubota Corporation when there is no Some other abnormality or failure has been found occurring Kubota Dealer in your neighbourhood Always discontinue use when phenomena listed sonal ee at right appear KUBOTA CORPORATION http www centrifuge jp 29 9 Hongo 3 chome Bunkyo ku Tokyo 113 0033 Japan Tel 81 3 3815 1331 Fax 81 3 3814 2574 E mail f trade kubotacorp co jp Note This catalogue is not for distribution in the USA Canada Mexico and Australia as products shown are not for sale in these countries Copyright 2008 KUBOTA CORPORATION J DEC Printed in Japan NOO
8. min increments Temperature setting and indicatione digital display 20 C to 40 C 1 C increments Refrigerante R134a CFC free Power reguirements e Single phase 50 60Hz 110V 10 15A 115V 10 15A Single phase 50 60Hz 220V 10 10A 230V 10 10A Rated voltage and rated currente 110V 11A 115V 10A 220V 7 0A 230V 6 6A Power consumption and heat outpute 110 115V 990W 3 6MJ h 220 230V 1 1kW 4 0MJ h Dimensions weight e 50cm x 65cm x 85cm WxDxH 9 117kg Certificates of conformity e IEC 61010 2 020 Except when RA 410M3 rotor is used CE Mark AC220V and 230V versions 1 Not including projections ALI specifications and external appearance are subject to change without notice Use only rotors adaptors and tube racks made by KUBOTA Do not attempt to use rotors adaptors or tube racks made by other manufacturers Follow all instructions in the relevant Instruction amp Service Manual when operating centrifuges Kubota has acquired ISO 9001 and ISO 13485 certification For your safe use of the eguipments be sure to read Parts may be adversely affected by heat humidity and specimens or the instruction manual carefully before you start its deteriorated by aging resulting in functional failures or may even lose their operation safety characteristic to cause accidents Safety Precautions The rotor or bucket has been found to be damaged or corroded To prevent occurrences of functional failures or accidents A burnt sme
9. ntheses indicate speeds when using optional shield covers No 027 9210 4 175mL 200mL and 225mL conical tubes can be centrifuged if cushions are used No 352090 cushions must be used with 175 amp 225mL conical tubes made by BD Falcon No 352076 amp No 352075 No 377585 cushions must be used with Nunc 200mL bottles No 376813 5 Various sputum tube capacities can be used Contact our distributor for details D Autoclavable 121 C a PT 89M PT 21M PT 745MS Plate rotor Plate rotor Plate rotor Can do ethanol precipitation at 3 100 Accepts 8 micro plates or 4 deep 12 micro plates and 4 deep well xg well plates plates can be set Ethanol precipitation can be performed at 3 100 xg 6 Corning No 431123 tubes require No 431124 cushions O 7 Verify plate strength before centrifuging Plates in lower position may fracture 8 Optional 027 9300 sealing caps can be used except with 500mL conical tubes 9 Facilitates removing plates from buckets 10 Nunc plastic tubes No 3110 0120 and No 3117 0120 O 11 BD Falcon plastic tubes Nos 352006 352018 and 352059 u No 3118 0050 and No 3119 0050 13 Herolab botiles 650mL PPCO PC 14 Stainless bottles are available 12 Nunc plastic tubes No 3110 0500 No 3110 9500 No 3112 0050 No 3114 0050 No 3117 9500 Autoclave parameters should not be exceeded Refer to operation and service manual AT 508C Fixed angle rotor 50 15mL x 8 conical tub
Download Pdf Manuals
Related Search
Related Contents
TE200 Series Digital Card User Manual User Manual - Biomol GmbH IO テスト FITC 標識抗体 CD10 IOB5a Guide de l`utilisateur クーラー取扱説明書抜粋 AP 720STM Manuel d`utilisation de l`écran LCD 200-SL002取扱説明書 - サンワダイレクト Manuale di installazione e manutenzione Sensore allo stato Manual Primo 413 by Doro Copyright © All rights reserved.