Home
Badu® EcoM3 - INYOPools.com
Contents
1. 5 Hand tighten the lid to make an air tight seal Do not use any tools to tighten the lid hand tighten only Make sure all valves are open and the unions are tight 6 Once all the air has left the filter close the pressure release valve 7 Switch on power to the pump motor to start There will be a delay of six to twelve 6 to 12 seconds as the EcoM3 powers up 8 The unit will automatically run on high speed for two 2 minutes to prime the pump After the two minutes the pump will default to low speed Note If you press the medium or high button during the two 2 minute priming the pump will then run for two 2 hours on the speed you selected then default back to low 9 The pump has three 3 speed settings low medium and high High Speed Used when vacuuming the pool or operating the spa jets or some water features such as water falls Medium Speed Used for gentle spa jet action or filtration for the pool Low Speed Recommended for everyday filtration of your pool This speed will achieve the lowest operating costs with the lowest noise level 10 If the power is turned off to the pump it will repeat this process See number 6 11 Ifthe pump does not prime and all the instructions to this point have been followed check for a suction leak If there is a leak repeat Steps 2 through 6 12 For technical assistance call Soeck Pumps Technical Support at 800 223 8538 5 Service and Maintenance Routine Maint
2. BONDING AND GROUNDING 1 The motor frame must be grounded to a reliable grounding point using a solid copper conductor No 8 AWG or larger In Canada No 6 AWG or larger must be used If the pump is installed within five 5 feet of the inside walls of the swimming pool spa or hot tub the motor frame must be bonded to all metal parts of the swimming pool spa or hot tub structure and to all electrical equipment metal conduit and metal piping within five 5 feet of the inside walls of the swimming pool spa or hot tub 2 Bond the motor using the provided external lug WARNING Always disconnect the power source before working on a motor or its connected load WARNING In order to avoid the risk of property damage severe personal injury and or death make sure that the control switch time clock or control system is installed in an accessible location so that in the event of an equipment failure or loose plumbing fitting the equipment can be easily turned off CAUTION The pump must be permanently connected to a dedicated electrical circuit No other equipment lights appliances or outlets may be connected to the pump circuit with the exception of devices that may be required to operate simultaneously with the pump such as a chlorinating device or heater WARNING Motor fitted with internal auto reset May restart without warning Electrical Wiring 1 The pump motor must be securely grounded using the 10 green headed groun
3. height between the pump and water level should not be more than five 5 feet If the pump is located below water level isolation valves must be installed on both sides of the pump to prevent the back flow of pool water during any routine or required servicing The Badu EcoM3 comes equipped with unions on both the suction and discharge ports This feature simplifies installation and service and eliminates the possibility of leaks at the threaded adaptors Before starting the pump for the first time remove the see through lid Turn lid counter clockwise to remove Fill strainer tank with water until it is level with the suction inlet Replace lid making sure the o ring is not damaged Screw down hand tight Suction and discharge line should be independently supported at a point near the pump to avoid strains being placed on the pump Always use properly sized valves Use the fewest fittings as possible Each additional fitting has the effect of moving the equipment farther away from the water NOTE If more than ten 10 suction fittings are needed the pipe size must be increased Every new installation must be pressure tested according to local codes See the Pressure Testing Section on page 7 Electrical Installation 10 Electrical Installation When installing and using the motor basic safety precautions should always be followed The wiring of the motor should be done by a licensed electrician in accordance with local codes
4. workmanship for a period of twenty four 24 months from the date that the pump is originally installed 2 Not withstanding any provisions herein to the contrary the warranties and obligations hereunder shall not in any event extend for more than three 3 years beyond the date of shipment of the pump and motor from the factory in Jacksonville Florida 3 Warranty is void in the following cases damages which result in whole or in part from a careless or improper installation of the pump or the motor b improper or negligent use and maintenance of the pump or the motor c tampering with the pump or the motor by unauthorized repair personnel 4 The manufacturer s sole obligation hereunder shall be to replace or repair any defective pump or motor The manufacturer reserves the absolute right to determine whether any defective pump or motor should be replaced or repaired 5 Any customer who wishes to make a claim under this Limited Warranty shall notify the manufacturer of such claim by telephone or by mail After the customer has been authorized to return a defective pump or motor the customer must return the pump or motor to the manufacturer at 8125 Bayberry Road Jacksonville Florida 32256 Any goods returned to manufacturer without prior authorization will be returned to the shipper unopened The manufacturer shall not bear any costs or risks incurred in shipping a defective pump or motor to the manufacturer or in shippin
5. 57700 2921150700 160 1 160 2 412 1 143 101 582 894 1 595 914 1 412 5 174 2 230 433 412 2 161 2 113 914 2 554 2 721 721 1 721 amp 721 1 25 507 D pe lt A E TR A OY eat a a a a et wk ek Ce gk Se es fr 160 EL 160 1 DESCRIPTION LID LOCK RING LID O RING LID 137 x 5mm BASKET ONE PIECE CASING CAP DRAIN 3 8 WITH GASKET CASING LEGO SPACER GASKET 1 4 x 7 16 x 1 SCREW CASING HEX SLOT M7 x 48mm SS O RING DIFFUSER 90 x 5mm DIFFUSER IMPELLER ll 1 0HP S F 1 0 101 9 0mm M10 MECHANICAL SEAL 14mm O RING CASING 190 x 6mm SEAL HOUSING 14mm FLANGE BOLT FLANGE M8 x 25mm WASHER FLANGE BOLT M8 SET DISCHARGE UNION COMPLETE SET SUCTION UNION COMPLETE COMPLETE UNION SET SUCTION DISCHARGE SPANNER LID OPTIONAL SLINGER SPLASH RING 60 50 40 30 3450 RPM TOTAL HEAD IN FEET 20 10 2600 RPM 600 RPM 0 20 40 60 80 100 120 GALLONS PER MINUTE A B C and D represent California Title 20 System Curves A 117 PVC Pipe SCH40 C 2 PVC Pipe SCH40 B 114 Copper Pipe D 212 PVC Pipe SCH40 8 Limited Warranty The manufacturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and condi tions 1 The pump and motor are warranted to be free from defects in material and
6. Installation Operating and Service Manual Badu EcoM3 Swimming Pool Pump A POOL PRODUCTS INCORPORATED Technical Support Address Hours Toll Free Phone Fax Web site Speck Pumps 8125 Bayberry Road Jacksonville FL 32256 USA 8 00 am to 5 00 pm EST 800 223 8538 904 739 2626 904 737 5261 www usa speck pumps com O 2010 All Rights Reserved Speck Pumps Jacksonville Florida USA This document is subject to change without notice Date of Installation Installed By Serial Number For Service Call o 2999999978 Rev 03 2010 SAVE THESE INSTRUCTIONS Table of Contents Important Safety Instructions 1 General Description 7 Installation Information 8 Preparation Guide 8 Pump Location 8 Pipe Sizing 9 Plumbing Installation 9 Electrical Installation 9 Bonding and Grounding 10 Electrical Wiring 10 Setting Up Remote Control 11 Voltage Checks 11 Pressure Testing 11 Operation 12 Service and Maintenance 13 Routine Maintenance 13 Winterizing 14 Troubleshooting 14 Controller Warnings poa 14 General Troubleshooting Problems 15 Product Specifications 16 Replacement Parts and Exploded View 16 Performance Curves 17 Limited Warranty 17 1 Important Safety Instructions READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP READ AND FOLLOW ALL INSTRUCTIONS Important Notice This manual contains important information about the ins
7. age and void the warranty There are two options when winterizing the pump Option 1 1 Drain all the water from the pump system equipment and piping 2 Remove drain plugs Do not replace plugs Store the plugs in the empty strainer basket for winter 3 Keep the motor covered and dry Option 2 1 Drain all the water from the pump system equipment and piping 2 Remove the pump and motor from the plumbing and store indoors in a warm and dry location Note When the winter season is over the pump will need to be primed prior to start Refer to Section 4 Operation Start Up Guide CAUTION DO NOT run the pump dry If the pump is run dry the mechanical seal will be damaged and the pump will start to leak If this occurs the mechanical seal will need to be replaced ALWAYS maintain the proper water level in your pool Continued operation in this manner could cause a loss of pressure resulting in damage to the pump casing impeller and mechanical seal 6 Troubleshooting WARNING The pump must serviced by a professional service technician qualified in pool spa installation The following procedures must be followed exactly Improper installation and or operation can create dangerous electrical hazards which can cause high voltage to run through the electrical system This can cause property damage serious personal injury and or death Improper installation and or operation will void the warranty The Badu EcoM3 warnings are indi
8. cated by a flashing LED light on the control panel If the error light is on pay attention to the appropriate number of flash intervals of short or long duration then shut the pump down immediately For example if a Low Voltage warning occurs the LED will blink two times then off then blink two times This sequence is repeated until the condition is cleared Table 2 0 The Badu EcoM3 Warning Sequence Flash Rate LED Error Light Error Description Cause 1 Flash Microprocessor failure Microprocessor Start Up 2 Flashes Low voltage Voltage must exceed lt 208V AC control activates itself independently when voltage exceeds 208V for more than six 6 seconds Motor Activates 3 Flashes Temperature to high Temperature Too High gt 100 C 212 F Temperature to low Temperature Too Low lt 20 C 4 F 4 Flashes Thermal overload tripped Motor is drawing to much current amps 5 Flashes High voltage Voltage has risen gt 269V AC 6 Flashes Shaft locked Impeller or pump locked motor shaft stopped turning 7 Flashes Self test One or more self test were not completed 8 Flashes Motor Error One or more phases is disconnected General Pump Troubleshooting Problems Table 2 0 The Badu EcoM3 General Problems Problem Possible Cause Solution 1 Error Light appears during start up A Low Voltage During the initial start up 6 12 sec onds delay or momentary power dr
9. ce and maintenance 4 Protect the pump against flooding and excess moisture and event foreign objects from clogging air circulation around motor All motors generate heat that must be removed by providing proper ventilation 5 DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this pump DO NOT store pool chemicals near the pump 6 DO NOT remove any safety alert labels such as DANGER WARNING or CAUTION Keep safety labels in good condition and replace any missing or damaged labels 7 Provide access for future services by leaving a clear area around the pump Allow plenty of space above the pump to remove lid and basket for cleaning Pipe Sizing NOTE All pipe sizes are able to withstand the pressures the pump will deliver but not necessarily the flow If the pipe is too small for the pump or is elevated above water the maximum gallons per minute GPM may not be delivered If this happens the pump will develop a pocket of air cavitation that makes noise This may shorten the life of the pump SUCTION amp DISCHARGE When the pump is located up to 50 feet from the pool the recommended minimum pipe size for both the suction and discharge is 2 for 0 75 HP to 1 5 HP full rated pumps Plumbing Installation When installing the pump care should be taken to see the suction line is below water level to a point immediately beneath the pump to ensure quick priming via a flooded suction line The
10. d Drain covers must be listed certified to the latest published Hazardous suction edition of ANSI ASME A112 19 8 They must be replaced if cracked Can trap hair or body broken or missing parts causing severe injury or death Do net block suction Number of Suction Outlets Per Pump Provide at least two 2 hydraulically balanced main drains with covers as suction for each circulating pump suction line The centers of the main drains suction outlets on any one 1 suction line must be at least three 3 feet apart center to center The system must be built to include at least two 2 suction outlets drains connected to the pump whenever the pump is running However if two 2 main drains run into a single suction line the single suction line may be equipped with a valve that will shut off both main drains from the pump The system shall be constructed such that it shall not allow for separate or independent shutoff or isolation of each drain More than one 1 pump can be connected to a single suction line as long as the requirements above are met Water Velocity 7he maximum water velocity through the suction fitting or cover for any suction outlet must be 1 5 feet per second unless the outlet complies with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas Hot Tubs and Whirlpool Bathtub Applications In any case do not exceed the suction if fi
11. d screw provided inside the motor terminal box NOTE Do not connect to electric power supply until unit is permanently grounded 2 Wire size must be adequate to minimize voltage drop during the start up and operation of the pump See Table 1 for recommended wiring sizes 3 Insulate all connections carefully to prevent grounding or short circuits Sharp edges on terminals require extra protection To prevent the wire nuts from loosening tape them using suitable listed UL ETL CSA electrical insulating tape For safety and to prevent entry of contaminants reinstall all conduit and terminal box covers Do not force connections into the conduit box Table 1 0 Recommended Wire Sizes for the Badu EcoM3 Recommended Wire Sizes For The Badu EcoM3 Distance from Sub panel 0 50 Feet 50 100 Feet 100 150 Feet Voltage 208 230 VAC 208 230 VAC 208 230 VAC Minimum Wire Size 12 10 8 Setting up the remote control The Badu EcoM3 consists of an operator control panel and the system electronics that drive the motor along with a ten 10 foot remote controller cord Speeds can be changed by the controller at the top of the motor or remotely by use of a remote controller External controller not provided available through Speck Pumps This pump can also be plugged into an external controller such as a time clock to meet all existing state or local codes Figure 2 A3 Channel time clock with potential free contac
12. edium head pump uses a state of the art axial flux permanent magnet brushless DC motor controlled by advance logic electronics Providing cooler and quieter operation at a fraction of the cost of a standard PSC motor The affinity laws of hydraulics states that if you halve the speed the power reduces by 8 times The multiple speeds offered by the Badu EcoM3 enables it to run slower and consume less energy but still have the ability to run at full speed if required The Badu EcoM3 operates at a maximum system flow of 100 gallons per minute GPM This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600 2600 and 3450 RPM This allows you to select the most appropriate speed for your application The Badu EcoM3 was designed to meet the needs of today s more environmentally friendly consumer The pump parts are made of 100 recyclable environment friendly plastic The axial flux brushless DC motor has a significant reduction in greenhouse gas emissions Saving greater than 2 tonne CO per year Lower noise reduction and energy savings per year The Badu EcoM3 control panel provides manual speed con trols for the pump There are three preset speed buttons that can be selected low medium and high Controls and LEDs 1 low med and high button LED Press one of the buttons to select the desired preset pump speed The pump preset speeds are low 1600 RPM med 2600 RPM and high 3450 RPM The button green LED is on wh
13. en the selected button is pressed 2 Power LED This green LED light is on when the Badu EcoM3 pump is powered up E 3 Error LED This red LED is on whenever an error has oc Power Error curred A Figure 1 3 Installation Information Preparation Guide 1 Upon receipt of the pump check the carton for damage Open the carton and check the pump for concealed damage such as cracks dents or a bent base If damage is found contact the shipper or distributor where the pump was purchased 2 Inspect the contents of the carton and verify that all parts are included See Section 7 Parts List and Exploded View Pump Location NOTE In Canada the pump must be located a minimum of three 3 meters approximately ten 10 feet from the water CSA C22 1 1 Speck Pumps recommends to achieve better self priming install the pump as close to the pool as practical Consult local codes for minimum distance between pool and pump WARNING Some Safety Vacuum Release System SVRS devices are not compatible with the installation of check valves If the pool has an SVRS device be sure to confirm that it will continue to safely operate when the check valves are installed 2 The piping should be as direct and free from turns or bends as possible as elbows and others fittings greatly increase friction losses 3 Place pump on solid foundation which provides a rigid and vibration free support so that it is readily accessible for servi
14. enance This pump requires little or no service other than reasonable care and periodic cleaning of the strainer basket 1 Inspect the pump basket for debris by looking through the clear pump lid 2 Turn off the power to the pump If the pump is located below the water level close isolation valves on the suction and discharge sides of the pump to prevent back flow of water 3 Remove any debris because as the debris accumulates it will begin to block the flow of water through the pump Keep the basket clean and clear to improve the performance of the pump 4 Turn the lid s lock ring counter clockwise until it stops Carefully remove the lid and lock ring 5 Remove the basket and properly dispose of the debris into the trash and rinse out the basket Check basket for cracks if crack is found replace basket 6 Replace basket back into the pump align the basket properly with the suction pipe Then fill with water up to the suction pipe Clean clear cover lid o ring and sealing surface of the pump of any debris 14 Routine Maintenance continued 6 Replace lid with locking ring Hand tighten the lid to make an air tight seal Do not use any tools to tighten the lid 7 Verify that all valves have been returned to the proper position for normal operation Turn on the power to the pump Winterizing CAUTION The pump must be protected when freezing temperatures are expected Allowing the pump to freeze will cause severe dam
15. g a repaired or replaced pump or motor to a customer 6 The manufacturer will charge customers for all non warranty work which it may perform Non warranty work will not be performed until the customer has accepted the price quoted 7 EXCEPT AS SPECIFICALLY SET FORTH ABOVE NO OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE MADE BY THE MANUFACTURER IN NO EVENT WILL THE MANUFACTURER BE LIABLE FOR ANY LOSS INCLUDING TIME MONEY GOODWILL LOST PROFITS AND CONSEQUENTIAL DAMAGES BASED ON CONTRAST TORT OR OTHER LEGAL THEORY WHICH MAY ARISE HEREUNDER OR FROM THE USE OPERATION OF MODIFICATION OF THE PUMP MOTOR OR ASSOCIATED PARTS THE MAXIMUM LIABILITY OF THE MANUFACTURER HEREUNDER SHALL NOT EXCEED THE AMOUNT ACTUALLY PAID BY THE CUSTOMER FOR THE PUMP MOTOR AND ASSOCIATED PARTS 8 Some states do not permit limitations on the terms of implied warranties or on the recovery of incidental or consequential damages Accordingly the limitations contained in paragraph 7 may not apply to certain customers 9 This warranty gives customers specific legal rights Customers may have other rights which vary from state to state 17 2999999978 Rev 03 2010 v1
16. ide a properly located outlet For swimming pool pumps with or without a maximum 3 foot 0 91 m cora CAUTION This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity TO REDUCE THE RISK OF ELECTRICAL SHOCK connect ground wires to grounding screw located in the motor Use no smaller than a 12 AWG 3 3mm2 wire TO REDUCE THE RISK OF ELECTRICAL SHOCK a bonding connector is provided for bonding to metal water pipes metal rails or other metal within 5 feet of the swimming pool All local points should be bonded with a 8 AWG 8 4mm2 wire For hot tub and spa pumps CAUTION Do not install within an outer enclosure or beneath the skirt of a hot tub or spa unless so marked SAVE THESE INSTRUCTIONS 2 General Description Badu EcoM3 The Badu EcoM3 swimming pool pump is both environment friendly and cost efficient This revolutionary three speed pump provides the pool owner a simple three button control to operate the pump greatly reducing the operating cost at a reasonable investment The robust pump is based on Speck Pumps energy efficient design platform The Badu EcoM3 high performance m
17. op in which case the pump will restart itself after the voltage is above 208V for a period of six seconds 2 Pump will not prime A Suction air leak B No water in pump C Closed valves or blocked lines D Low voltage to motor Make sure see through lid and o rings are clean and properly positioned Hand tighten see through lid Tighten all pipes and fittings on suction side of pump Be sure water in pool is high enough to flow through skimmer Make sure strainer tank is full of water Open all valves in system Clean skim mer and strainer tank Open pump and check for clogging of impeller Check voltage at motor If low pump will not come up to speed 3 Motor does not turn A No power to motor B Pump jammed Check that all power switches are on Be sure fuse or circuit breaker is properly set Time set properly Check motor wiring at terminal With power off turn shaft It should spin freely If not disassemble and repair 4 Low flow A Dirty filter B Suction Leak Back wash filter when filter pressure is high or clean cartridges See Problem 2 15 16 Product Specifications PART NUMBER DRAWING NUMBER 2921116010 2921116020 2901141201 2901114300 2921110108 2901158200 2920889410 2920889420 2991000088 2920141210 2921117412 2920723101 2920143310 2921141222 2921116125 2921111300 5879120825 2991000062 2500300902 2921770001 2500300914 29211
18. stem with water air is often trapped in the system during the filling process This air will compress when the system is pressurized Should the system fail this trapped air can propel debris at a high speed and cause injury Every effort to remove trapped air must be taken including opening the bleed valve on the filter and loosening the pump basket lid while filling the pump WARNING Trapped air in the system can cause the filter lid to be blown off which can result in death serious injury or property damage Be sure all air is properly purged out of the system before operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS 11 12 Pressure Test continued WARNING When pressure testing the system with water it is very important to make sure that the pump basket and lid is completely secure STEPS 1 Fill the system with water using care to eliminate trapped air 2 Pressurize the system with water to no more than 35 PSI WARNING Do not pressure test above 35 PSI Pressure testing must be done by a trained pool professional Circulation equipment that is not tested properly might fail which would result in severe injury or property damage 3 Close the valve to trap pressurized water in the system 4 Observe the system for leaks and or pressure decay 5 If there are leaks repeat Steps 1 3 For technical support call 1 800 223 8538 4 Operation CAUTION Never run the pump without water Running
19. tallation operation and safe use of this product This information should be given to the owner and or operator of this equipment WARNING Before Installing this product read and follow all warning notices and instructions which are included Failure to follow safety warnings and instructions can result in severe injury death or property damage Call 1 800 223 8538 or visit www usa speck pumps com for additional copies of these instructions WARNING Entrapment Prevention DANGER DO NOT BLOCK SUCTION SUCTION HAZARD Can cause serious injury or death Do not use this pump for wading pools shallow pools or spas containing bottom drains unless pump is connected to at least two 2 functioning suction outlets 44 DANGER WARNING Pump suction is hazardous and can trap and drown or IL disembowel bathers Do not use or operate swimming pools spas or Hazardous suction hot tubs if a suction outlet cover is missing broken or loose Can trap hair or body parts causing severe injury or death Do not block suction The following guidelines provide information for pump installation that minimizes risk of injury to users of pools spas and hot tubs A DANG ER Entrapment Protection The pump suction system must provide protection against the hazards of suction entrapment Suction Outlet Covers A suction outlets must have correctly installed screw fastened covers in place All suction outlet drain covers must be maintaine
20. th or serious injury to pool users installers or others due to electrical shock and may also cause damage to property A WARNING seal ees aig Always disconnect power to the pool pump at the circuit breaker causa death before servicing the pump Failure to do so could result in death or Disconnect power before serious injury to serviceman pool users or others due to electric shock working on pump or motor Important Safety Precautions When installing and using this electrical equipment basic safety precautions should always be followed including the following READ AND FOLLOW ALL INSTRUCTIONS For all units WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times For cord and plug connected units WARNING Risk of Electrical Shock Connect only to a grounding type receptacle protected by a ground fault circuit interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI For cord and plug connected units WARNING Do not bury the cord Locate cord to minimize abuse from lawn mowers hedge trimmers and other equipment For cord and plug connected units WARNING To reduce the risk of electrical shock replace damaged cord immediately For cord and plug connected units WARNING To reduce the risk of electrical shock do not use extension cord to connect unit to electrical supply prov
21. the pump dry for any length of time can cause severe damage to both the pump and the motor and will void the warranty If this is a new pool installation make sure all piping is clear of construction debris and has been properly pressure tested The filter should be checked for proper installation verifying that all connections and clamps are secure according to the manufacturer s recommendations WARNING To avoid risk of property damage severe personal injury or death verify that all power is turned off before starting this procedure 1 Release all pressure from the system and open the filter pressure release valve 2 Depending on the location of the pump do one of the following If the pump is located below the water level of the pool open the filter pressure valve to prime the pump with water If the pump is located above the water level of the pool remove the lid and fill the basket with water before starting the pump DO NOT run the pump without the basket 3 Make sure pump turns freely especially after extended periods of down time Note To turn the shaft place a screwdriver into the slot at the fan end and turn it by in the direction of rotation If necessary remove the fan cover and turn the fan by hand After re starting make sure the mechanical seal does not leak 4 Prior to replacing the lid check for debris around the lid o rings seat Debris around the lid o ring seat will make it difficult to prime the pump
22. ts Also called dry contacts A device using momentary switches would also work NOTE If remote controller cable is not used the wiring needs to be isolated The ends MUST NOT TOUCH or the speeds may be affected To Connect to a Remote Controller 1 Remove power from the Badu EcoM3 by disconnecting the high voltage lines or by opening any breaker to which the pump power is connected WARNING Electrical Shock Hazard Turn off all switches and main breaker in the Badu EcoM3 electrical circuit before starting the procedure Failure to comply p Red High 3450 RPM may cause a shock hazard resulting in zs Blue Medium 2600 RPM severe personal injury or death White lt Low lt 1600 RPM 2 For technical assistance call Speck Pumps Technical Support at Black lt Common 800 223 8538 Figure 2 Voltage Checks The correct voltage as specified on the pump data plate is necessary for proper performance and long motor life Incorrect voltage will cause the error light to turn on and cause damage to the motor if not turned off immediately It is the responsibility of the electrical installer to provide data plate operating voltage to the pump by ensuring proper circuit sizes and wire sizes for this specific application CAUTION Failure to provide data plate voltage during operation will cause the motor to overheat and void the warranty Pressure Test WARNING When pressure testing a sy
23. tting s maximum designed flow rate If 100 of the pump s flow comes from the main drain system the maximum water velocity in the pump suction hydraulic system must be six 6 feet per second or less even if one 1 main drain suction outlet is completely blocked The flow through the remaining main drain s must comply with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas Hot Tubs and Whirlpool Bathtub Applications Testing and Certification Suction outlet covers must have been tested by a nationally recognized testing laboratory and found to comply with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas Hot Tubs and Whirlpool Bathtub Applications Fittings Fittings restrict flow for best efficiency use fewest possible fittings but at least two 2 suction outlets Avoid fittings that could cause an air trap Pool cleaner suction fittings must conform to applicable International Association of Plumbing and Mechanical Officials IAPMO standards WARNING Risk of Electrical Shock or Electrocution This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances Improper installation will create an electric hazard which could result in dea
Download Pdf Manuals
Related Search
Related Contents
FILTRI DEFERRIZZATORI AUTOMATICI SERIE: FDV/T ST-213取説出稿 [更新済み]-1 和訳 - 国際エネルギースタープログラム Amana AGR4230BAW Installation Instructions AEG Eclipse 10 Sierra M6-2 SAS/SATA Protocol Analyzer User Manual A Learning Model for 8051 Microcontroller Case Study on 115122-luzerne brins longs フジトップカラーECⅢ 主剤 ETUDE COMPARATIVE DE PLUSIEURS PHYTASES SUR Copyright © All rights reserved.