Home

Side-by-Side Refrigerator

image

Contents

1. ro REF FOUNTAIN O H mye ER Il GMT FZ DOOR HARNESS REF LINER HARNESS D P sviten HEATER SOLENOID 1 4 9 a TFE COMM S sl 2 LO SUPER RO WH D RD WH z HHE LONER REF LIGHT E 16 SPLICE DISPLAY HARNESS REF LIGHTS m HARNESS CONTROL BOARD 1 SPORTS FILL A el SWITCH age 7 Pi Bk CONTROL HARNESS ER HJ 3 2 LV SWITCH HARNESS EE GN YL GN YL GN YL aisle DOOR PAN DOOR PAN es SOLENOID NON FOAM 5 E 5 N Y AUGER MOTOR zlalsl l le 88 an DOOR IHINGE HARNESS EN emjx 2 o we ae E AUGER UPPER UPPER MTR c C FREEZER C FREEZER 1 zd LIGHT C LIGHT afaj 111551 ewrhE m L EN SIE x 2 gt AR zlzl lalz iz P gt 5 Mai EHE G TT ATT MOTORIZED DAMPER Sets F Eli FZ LINER HARNESS L 5 RD gt Fars SE m EE BERG WH BU WH BU L AUTOMATIC 7177 WH YL vr HS CONNECTOR MAKER eepe RUE 515 GN YL GN YL apa WH BU RD ee EE gp cAn 414 eg EL wou HH WH OR sleeve E 5 E CAPACITOR WH WH F2 THERMISTOR pr F2 H LITE Hts
2. NOTE By pushing Actuator pad you can control state of Crusher dispenser without opening Ice Chute door Service Test 163 Water Dispenser if equipped e Display shows the state of the Water Dispenser ON or OFF NOTE By pushing Actuator pad or Bottle fill you can control state of Water dispenser February 2006 5 16026985 2006 Maytag Services Service Specifications 4 amp amp WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization Service Test 164 Ice Chute Dispenser if equipped e Display shows the state of the Ice Chute dispenser ON or OFF NOTE By pushing Actuator Pad you can control state of Ice Chute Dispenser Service Test 165 Dispenser Lamp if equipped e Display shows the state of the Dispenser Lamp ON or OFF NOTE By pushing Actuator Pad or Bottle Fill you can control state of dispenser lamp Service Test 171 Actuator Pad if equipped e Display shows the state of the Actuator Pad ON OFF Service Test 172 Sports Fill if equipped e Display shows the state of the Sports Fill ON or OFF Service Test 173 Ambient Light if equipped e Display shows light sensor measurement Hi or Lo Nig
3. and Down Keypad force to dEF default factory settings closed February 2006 7 16026985 2006 Maytag Services Wiring Diagram 4 amp amp WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization
4. 1 2 12 VDC SPDT NO NC 125 250 VAC 1010hms 10 16026985 2 February 2006 2006 Maytag Services Service Specifications 4 amp amp WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization Programming Mode NOTE The Program Code is located on the Serial Plate on this unit after the word Code Door Open the Fresh Food door and press and hold the Door Alarm Keypad dm 2 Press and hold Freezer Temperature Down Keypad 3 Release the Door Alarm Keypad and wait 3 seconds 4 The control will display PE to indicate the programming mode Freezer H Order Replace Bons o 1 Alarm Refrigerator BESS c sy CF a 5 Entry is confirmed by pressing the Freezer Temperature Down Keypad C once more 6 The control will display the current Program CODE This value should be validated with the Program CODE NOTE If the Program CODE is correct the Programming Mode is exited by closing the Refrigerator door s 7 Press the Refrigerator Temperature Up Keypad CI or Refrigerator Down Keypad to change the digit value with each key press 8 The decimal point indicates the selected digit
5. Press the Freezer Temperature Up Keypad Cp to select the next digit 9 Once the desired Program CODE is displayed press and hold the Freezer Temperature Down Keypad until the Program CODE begins flashing indicating it has been saved NOTE If you attempt to enter an invalid Program CODE the control will not save the new code but will beep The unit will NOT run with a Program CODE of 0000 Once the Program CODE has been saved the Programming Mode is exited by closing the Refrigerator door s If the new code is incorrect this process should be repeated after closing the Refrigerator door s The Programming mode can be exited at any time by closing the Refrigerator Door s or will exit if unattended for four minutes Defrost Operation The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the length of time the defrost heater is on After initial power up defrost interval is 4 hours compressor run time Defrost occurs immediately after the 4 hours February 2006 3 16026985 2006 Maytag Services Service Specifications 4 amp amp WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure grounding polarization
6. Forced Defrost Mode The forced defrost function is performed using the Freezer display and Refrigerator keypad Enter the Forced Defrost Mode by performing the following sequence of events 1 Open the Fresh Food door and press and hold the Door Alarm Keypad 2 Press and hold Refrigerator Temperate Down Keypad Door N 3 Release the Door Alarm Keypad NER d and wait 3 seconds Fd appears in left display Refrigerator p 190291 ama 4 Press the Refrigerator Down Keypad E again SH appears in right display 5 Press again to force defrost Fd and SH will flash in display indicating unit is in defrost Service Test Mode The service test functions are performed using the refrigerator display and keypad Enter the Service Test Mode by performing the following sequence of events Door 1 Open the Fresh Food door and press and hold the Door Alarm Keypad 2 Press and hold Refrigerator Temperature Up Keypad Door Alarm 2 Release the Door Alarm and wait 3 seconds Order Replac Refrigerator noe jacation Temp Boor Max gt ode Aet Com Goal 4 Press the F frigariorb Down Keypad Pa again 5 Display will show 001 in left display and numeric or dashes in right display 6 Press Freezer Up Keypad CIS and Freezer Down Keypad to toggle through Service Test numbers Service Test 101 Defrost Heater amp Defr
7. SWITCH GN YL rt OR BK 5 1 Nc 2 SPLICE Low 5 RD Y T JE SPLICE R YL gk 919 DEFROST HEATER x BK GN DEFROST ad lt Sa z e OR WH BR eN YL SPLICE C GN YL Nc 11 EVAPORATOR FAN OR BK WH Spo 2 SPLICE m m 5 52 5 5 cer e s sese HARNESS HPEII LOWER FREEZER LIGHT w o x xJo zJol a BU 3 SSS Ssss Harness HARRE x z WH l m COMP z GROUND a e BASE PAN amp 2 2 x gt ele x x ws GROUND 1 gt a AT BU 3 zi 55558 Sel 2 5 gt gt gt gt 5 aS 5 2 o Te r o I To e r e o leu CAES e Ais elei ojo Sg SNAN Q 8 en AUN WH SPa ANF BERIEED LES 5 a 2222 zc COMP mo zz 2 2fusrab 8 OVERLOAD CONDENSER wou z ZEEES 8 sf HEE nege 382g PTC RELAY FAN MOTOR Sr 18 5 sez 7 22482 Yz mS oo E ress 2 58 MC HARNESS Ej 13013303 PRINTED IN U S A 16026985 8 February 2006 2006 Maytag Services
8. Side by Side Refrigerator Technical Information JCD2292KT JCD2292KT 2 JCD2295KE JCD2295KE 2 JCD2297KE JCD2297KE 2 JSD2695KES JSD2695KES2 JSD2695KG JSD2695KG 0 JSD2697KE JSD2697KE 2 MSD2660KEG MSD2660KEG MSD2660KES MSD2660KESO CAUTION Due to a possibility of personal injury or property damage always contact an authorized technician for service or repair of this refrigerator All safety information must be followed as provided in Service Manual 16025628 4 WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless testing is required Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization No Load Performance Controls in Normal Position Refrigerator Center Compartment Average Freezer Percent Run Time Cycles 24 hr Food Temperature Compartme
9. grounding and polarization Component Specifications all parts 115VAC 60HZ unless noted Compressor run capacitor Compressor Current Full load Resistance Run windings Resistance Start windings Electric damper control Thermistor 220 VAC 15 ufd 10 905 BTUH 60 Hz 153 watts 19 0 amps 15 1 26 amps 15 3 33 ohms 15 4 28 ohms x 15 8 seconds 20 F 110 F Resistance 10 000 ohms 1 8 29 500 ohms 1 0 86 300 ohms 1 8 Condenser motor Evaporator fan motor on shaft to achieve proper airflow Ult trip amps 158 F 70 C Close temperature Open temperature Short time trip seconds Overload Relay Short time trip amps 77 F 25 C Thermostat Defrost Evaporator heater 22 amp 26 cu ft Evaporator heater 23 cu ft Control board Auger Motor Water Valve Super Cool Fan Light switch Interlock Solenoid Ice Chute Clockwise 1120 RPM 3 4 watts 15 115VAC 0 085 amps 15 115VAC Clockwise 2800 RPM 6 0 15 watts 115 VAC 2 40 amps 15 140 F 10 230 F 5 17 seconds 5 12 amps 2amps 120 240 VAC 475 watts 10 5 amps Closed 115 VAC 450 5 watts 115VAC 29 5 ohms 115 VAC 350 5 watts 115VAC 37 8 5 ohms 120VAC 60 HZ See Control board troubleshooting section Power to blue and white is clockwise Power to orange and white is counterclockwise 17 3 RPM Brown side 35w Yellow side 20w Counterclockwise 1530 250
10. ht light will turn on if light sensor measures Lo By changing the sensor s exposure to ambient light you can control the sensor measurement Service Test 174 Water Actuator Bottom Mount Internal Dispenser if equipped e Display shows the state of the Water Valve ON or OFF NOTE By pushing Water Actuator you can control state of Water Valve On or Off Service Test 175 Dispenser Line if equipped e Display shows the state of the Dispenser Line ON or OFF NOTE By pushing Actuator pad or Bottle fill you can change state of Dispenser Line Service Test 181 Keypad Operation e Display shows a numeric or letter display indicating the last key pressed NOTE Refrigerator Up Down keypads have no effect when pressed and Freezer Up Down keypads remain operational Service Test 182 LED Indicator Operation Press the Refrigerator Up Keypad L2 to show operation of LED Indicators All LED Indicators will flash Press twice and LED will stop flashing Service Test 191 Ice Maker Water Valve e Display shows the state of the Ice Maker Water Valve ON or OFF 16026985 6 February 2006 2006 Maytag Services Service Specifications 4 amp amp WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced
11. ning or closing it will not allow you to toggle damper and beep Display will show state CL or OP if Damper is in the process of closing or opening Service Test 131 3 Door Bottom Freezer Mullion Heater e Press the Refrigerator Up Keypad CES and Refrigerator Down Keypad gt toggle Mullion Heater Off and On Service Test 141 Fresh Food Thermistor e Will Show Fresh Food Temperature or OP for open thermistor or SH for shorted thermistor Service Test 142 Freezer Thermistor e Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor Service Test 143 Machine Compartment Thermistor e Will Show Machine Compartment Temperature or OP for open thermistor or SH for shorted thermistor Service Test 151 Fresh Food Door State e Will show state of Fresh Food Door OP open CL closed NOTE By pushing fresh food door switch you can toggle state from OP open to CL closed Service Test 152 Freezer Food Door State e Will show state of Freezer Door OP open CL closed NOTE By pushing freezer door switch you can toggle state from OP open to CL closed Service Test 161 Cube Dispenser if equipped e Display shows the state of the Cube Dispenser ON or OFF NOTE By pushing Actuator pad you can control state of cube dispenser without opening Ice Chute door Service Test 162 Crusher Dispenser if equipped e Display shows the state of the Crusher Dispenser ON or OFF
12. nt Kw 24 hr x0 4 10 25 3 F Average Food Temperature 3 F Ambient F 70 90 110 70 90 110 70 90 110 70 90 110 70 90 110 22 cu ft 1 2 1 85 2 6 35 55 75 24 24 19 37 39 42 0 0 2 23 cu ft 1 2 1 85 2 6 35 55 75 24 24 19 37 39 42 0 0 2 26 cu ft 1 2 1 85 2 6 35 55 75 24 24 19 37 39 42 0 0 2 Temperature Relationship Test Chart Suction Evaporator Evaporator Suction Line Average Total Pressure Head Pressure Outlet Inlet 7 F Wattage 10 2 PSIG 5 PSIG 3 F 3 F Ambient F 70 90 70 90 70 90 70 90 70 90 70 90 22 cu ft 15 15 16 16 72 98 132 138 6 Vac 0 87 137 23 cu ft 19 15 20 16 72 98 132 138 6 Vac 0 95 137 26 cu ft 15 15 16 16 72 98 132 138 6 Vac 0 87 137 Sw 1 T t I LE E le ME Be EINER 3 aig firm CERE ME s l 3 1 s 1 r E REC 5 NE zi 8 I ee r1 CE qnis 1 RM ble 3 ad rd ss eig 1 En i CZJ i TEE i 8 5 Sii E M B Lae EE February 2006 1 16026985 2006 Maytag Services Component Specifications WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper
13. on correct terminals to ensure proper grounding and polarization Service Test 201 Mullion Heater Override if equipped e Press the Refrigerator Up Keypad Hor Refrigerator Down Keypad SS to change Mullion Heater from cycling on with compressor Off position to 100 operation On Position Service Test 202 Default Defrost Operation e Press the Refrigerator Up Keypad Hor Refrigerator Down Keypad to change Defrost Operation from normal adaptive defrost Off position to minimum time between defrosts On position Service Test 203 Show Temperature Set points e Press the Refrigerator Up Keypad Yor Refrigerator Down Keypad to change from showing actual temperature Off position to show temperature set points only On position Service Test 211 Fresh Food Temperature Adjustment e Press the Refrigerator Up Keypad Mor Down Keypad CD to change calibration of Fresh Food Temperature plus or minus in 1 F increments up to 6 NOTE Temperature will read in Fahrenheit regardless of what current temperature scale is being used Service Test 212 Freezer Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Freezer Temperature plus or minus 1 in increments up to 6 F NOTE Temperature will read in Fahrenheit regardless of what current temperature scale is being used Service Test 221 Reset Default Settings Press the Refrigerator Up Keypad lt
14. ost Circuit e Press the Refrigerator Up Keypad and Refrigerator Down keypad CC to energize or de energize the Defrost circuit The display will read OFF when de energized OP when energized with open defrost thermostat and CL when energized with closed defrost thermostat Service Test 102 Compressor Condenser Fan e Press the Refrigerator Up keypad Refrigerator Down keypad C to toggle Compressor Condenser fan On and Off Service Test 111 Fresh Food Fan if equipped e Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Fresh Food Fan On and Off NOTE Display will show state OFF or DC voltage 16026985 4 February 2006 2006 Maytag Services Service Specifications 4 amp amp WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization Service Test 112 Freezer Fan e Press the Refrigerator Up Keypad Refrigerator Down keypad So toggle Freezer Fan On and Off NOTE Display will show state OFF or DC voltage Service Test 121 Damper Operation e Press the Refrigerator Up Keypad and Down keypad E to toggle Damper OP open and CL closed NOTE If damper is ope