Home

Operating Manual Electronic Baby Scale, M10615

image

Contents

1. requirements Furthermore Directive governing the electromagnetic compatibility 89 336 EEC is respected Use of the scale Weighing Power the scale by pressing the tilting switch underneath the base on the right hand side for min 3 seconds After start up an automatic function test is done which ends in switching into 0 00 position in kg weighing mode The scale is now ready to weigh In case of any irregularities in weighing procedure the display will show the error indication Err xxx In this case go to chapter Cleaning Maintenance and Re approval see point Service After 0 00 is displayed properly the scale can be loaded Make sure the baby does not move too much The correct weight can be read on the display Set zero By using the Zero key eventual irregularities occurred after start up the scale can be compensated by setting the display back to zero for all subsequent weighing procedures Tare function This function enables the user to weigh the baby together with other objects e g diaper vetst towel or blanket without getting any other result than just the baby s weight Start the scale by using the tilting switch underneath the base right hand side Zero the scale by pressing the Zero key if necessary The zero indicator will be seen on the display Place object e g diaper vest towel or blanket on the tray Press Tare key to come back to zero Display should show 0 00 The display
2. Operating Manual Electronic Baby Scale M10615 ADE GmbH amp Co Hammer Steindamm 27 29 22089 Hamburg GERMANY a 49 40 432776 0 Fax 49 40 432776 10 E mail info ade hamburg de Contents COMMS TAS A e EEE O O O 1 Components and Far o do o 2 Display SYMDOIS ansias o AS 2 Installaton and Use SCale naran dct nile nad adeeb a e a a a a e 3 CHECK Carton Contes aia iii R 3 Power SuppyorNeSCale ini dd ea et aaa ee di 3 POSITIONING of ING scale ica A Ii 3 A A e RT OR Ree 4 USONE scale lid A 4 A A O A A NAO 4 A E E A AS or PO UE ees eR ee eer eee egret eee ee eee he er eae eee oreo 4 Tare TUACION ni isla A E A 4 TONG URAC os 5 UNILANG ON tanane a a a teen ede ean 5 Cleaning amp Maintenant ii ed ote es ae eae ee T os ese ee ad 5 e a sadasame a eeestelog ies eie le ieee eee 5 eas eel ected Padi waar An es alacant 5 Sale y INSTUCIONS asii 5 storage and Map di 5 NM WAP A Ir PEOR A A eaG thie leanoaedee 6 CE marking and Declaration of Confor MV iii A A A A 6 Declaration of CE Cono MV casita dida 6 TOC GAGA ui a 6 1 050100 Rev000 M10615 Components and Features Attention the power switch is situated underneath the base of the scale right hand side Keys Function ZERO cisma To set scale to zero WPAN nera osos To tare any requested value HOLD sccacnncistcccasscedonnsses To fix the weighing result UNI essstossniisspibaais To change the weighing unit kg Ib OQOSS EEEE Indication of weight
3. Power Supply of the scale Any other failure messages on the display e g Err 4 Err 5 Err 6 or Err 9 please contact your local dealer or service partner or see Service Manual where instructions for authorized technical staff is available Safety instructions Do NOT use the scale e Ifthe mains adapter shows visible damages e f mains adapter is not working properly e After long storage in humid places In those cases contact your local dealer or service partner Storage and Transport Keep all original parts and pieces for an eventual sending back of the scale in order to avoid any possible damage during transport which automatically leads to no warranty Disconnect all cables before transport to avoid unnecessary damages 5 050100 Rev000 M10615 Warranty A two years warranty period from date of purchase will be guaranteed for either repair or replacement once it is proven that the defects are caused by poor material or poor workmanship please keep the receipt for presentation All moveable parts such as batteries cables plug in power supply units rechargeable batteries etc are excluded Warranty does not apply to normal appearance of usage or sign of wear or any damages caused by accidents or misuse Products which have been opened by unauthorized persons are automatically out of warranty Customers abroad are requested to contact their local dealers in the event of any warranty becoming applicable CE marking and Decla
4. otect the battery You can also identify status of battery charging by the colour of the LED control light placed in the left hand corner above the display When the scale is plugged into mains the power pack will be recharged automatically If LED is green the batteries have full charge If it is red the battery is nearly discharged and yellow indicates the battery is under charge Battery life becomes weaker if lifetime after charging becomes shorter In this case contact your local dealer or service partner Please make sure the local voltage supply corresponds to the indication printed on the adapter Positioning of the scale Place the scale on a level surface Make sure all four feet of the platform have direct contact to the surface The spirit level of the scale is an additional tool to make sure the scale is carefully positioned and offers best results when the air bubble is centred The alignment of the scale must be checked and corrected every time the location of the scale is changed 3 050100 Rev000 M10615 Quality check ADE products correspond to the applicable EC Directives and European standards to manufacture and distribute world wide weighing and measuring equipment as per the latest technical standard offering a long lifetime and continuous reliability T V ADE has been certified as per ISO 9001 2000 and fulfills the high standards for Research amp Development Manufacturing Sales and Service
5. ration of Conformity ADE products are manufactured as per the standards applicable of the actual European norms and directives to produce and offer world wide products at the latest technical standard and with a long lifetime Declaration of CE Conformit This product corresponds to the valid EC Directive 89 336 EEC for electromagnetic compatibility Products carrying this sign correspond to the standards of e Directive 73 23 EEC for low voltage Display Housing of Display Power supply Function keys Zero setting Max Capacity Graduation Dimensions WxHxD Weight Working Temperature Supplier 050100 Rev000 M10615 Technical data easy to read 20 cm LCD Display with backlight robust plastic housing Mains 4 rechargeable batteries 4 keys see chapter components 4 features automatic 20 kg 33 Ibs 1 g 0 25 oz 535 x 222 x 330 mm approx 4 5 kg 10 to 40 degrees Celsius ADE GmbH amp Co Hammer Steindamm 27 29 22089 Hamburg Germany
6. taken Murena lnea Indication that a tare value has been keyed in and is active O POERI EEE E E Indication that scale has been set to zero manually IN E A ae Indication that a stable value has been reached E tocado eb Indication that battery is low 050100 Rev000 M10615 2 Installation and use of scale Your ADE Electronic Baby Scale is a quality product and applicable for weighing in medical surroundings subject to the fact that the scale is used for statistical weight control of babies but not for determination of medical treatments or portions of medicine for which a class lll approved scale would be imperative due to national legislation It is a precision instrument and must be treated accordingly Therefore kindly read and follow the Operating Manual in all respects Check carton contents Babyscale Baby tray Mains adapter Operating Manual including Certificate of Conformity Power Supply of the scale By mains adapter 9V 800mA and rechargeable batteries power pack The battery pack is already installed in the base of the scale Charge the power pack by using the mains adapter and connect the jack firmly Complete first charging of power pack needs 24 hours The full battery life is approx 100 hours If power pack needs recharging there will be an arrow above the low battery symbol on the display Still the scale with operate for about 10 hours after which it will automatically switch off to pr
7. will show the tare indicator Place the baby on the tray The weight displayed is just baby s weight If the tarred objects remain always the same you may continue weighing another baby and the scale will only show the weight of the baby you are weighing Once the scale is shut off e g automatically in battery operating mode the stored value is cleared If the tare value is changing during operation of the scale complete unloading of the scale is necessary Additionally press zero key to return to normal status 050100 Rev000 M10615 4 Hold function Press the Hold key in case of unstable readout which might occur if for example the baby is constantly moving on the baby tray The scale will hold the result displayed After scale has been unloaded the result value is still readable and can be noted This allows taking care of the baby first Press Hold key again to return to normal status Unit function By using the Unit key you may select the weighing mode kg Ib Before weighing always make sure you are in the selected weighing mode Cleaning amp Maintenance Cleaning Before cleaning make sure the scale has been disconnected from the socket For cleaning just use a damp cloth or common disinfection products Do not use any aggressive cleaning fluids Make sure no water or cleaning fluid penetrates the scale Service Display indication Recharge the power pack by using the mains adapter see also page 3 chapter

Download Pdf Manuals

image

Related Search

Related Contents

KASPERSKY LAB - Parent Directory  I. eForm - Europa Creativa Desk    Samsung Samsung F480 คู่มือการใช้งาน  Philips 8718696411148 energy-saving lamp  ro-groover - super-ego  Tripp Lite SmartOnline 200-240V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, DB9 Serial  