r-120db r-120dk r-120dr r-120dw service manual

image

Contents

1. POWER TRANSFORMER INTERLOCK RELAY SWITCH MONITOR i SWITCH RECTIFIER MAGNETRON FAN MOTOR SECONDARY INTERLOCK SWITCH Figure O 1 Oven Schematic Off Condition 6 http dc 136 4shared com doc xqap_LFD preview html 3 25 2012 120DP TXT C T FUSE SCHEMATIC NOTE CONDITION OF OVEN 1 DOOR OPENED 2 COOKING TIME PROGRAMMED 3 DOOR CLOSED 4 START MINUTE PLUS BUTTON PUSHED Page 9 of 10 R 120DB R 120DK R 120DR R 120DW MAGNETRON THERMAL CUT OUT POWER TRANSFORMER CAPACITOR DOOR SENSING SWITCH MONITOR SWITCH RECTIFIER Figure O 2 Oven Schematic Cooking Condition DESCRIPTION AND FUNCTION OF COMPONENTS DOOR OPEN MECHANISM The door is opened by pulling the door refer to the Figure D 4 p f Latch heads 7 Latch hook Ma Door sensing switch Monitor switch Secondary interlock switch Figure D 1 Door Open Mechanism DOOR SENSING AND SECONDARY INTERLOCK SWITCHES The secondary interlock switch is mounted in the lower position of the latch hook and the door sensing switch in the primary interlock system is mounted in the upper position of the latch hook They are activated by the latch heads on the door When the door is opened the switches interrupt the power to all high voltage components A cook cycle cannot take place until the door is firmly closed thereby activating both interlock switches The pri
2. and then short circuit the connection of the high voltage capacitor that is the connecting lead of the high voltage rectifier against the chassis with the use of an insulated screwdriver Whenever troubleshooting is performed the power supply must be disconnected It may in some cases be necessary to connect the power supply after the outer case has been removed in this event 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4 Disconnect the leads to the primary of the power transformer 5 Ensure that the leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedure reconnect the power supply cord http dc 136 4shared com doc xqap_LFD preview html When the testing is completed 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4 Reconnect the leads to the primary of the power transformer 5 Reinstall the outer case cabinet 6 Reconnect the power supply cord after the outer case is installed 7 Run the oven and check all functions After repairing 1 Reconnect all leads removed from components during testing 2 Reinstall the outer case cabinet 3 Reconnect the power supply cord after the outer case is installed 4 Run the oven and check all functions Microwav
3. not deformed or warped E There is no other visible damage with the oven Servicing and repair work must be carried out only by trained service personnel DANGER Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing Service personnel Do not contact the following parts while the appliance is energized High Voltage Capacitor Power Transformer Magnetron High Voltage Rectifier Assembly High Voltage Harness If provided Vent Hood Fan assembly Cooling Fan Motor Ow All the parts marked 250V on parts list are used at voltages more than Removal of the outer wrap gives access to voltage above 250V All the parts marked on parts list may cause undue microwave exposure by themselves or when they are damaged loosened or removed SHARP ELECTRONICS CORPORATION SHARP PLAZA MAHWAH NEW JERSEY 07430 2135 http dc 136 4shared com doc xqap_LFD preview html Page 5 of 10 R 120DB R 120DK R 120DR R 120DW PRODUCT DESCRIPTION GENERAL INFORMATION OPERATION TROUBLESHOOTING GUIDE AND TEST PROCEDURE TOUCH CONTROL PANEL COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE WIRING DIAGRAM PARTS LIST 3 25 2012 120DP TXT Page 6 of 10 R 120DB R 120DK R 120DR R 120DW PRODUCT DESCRIPTION SPECIFICATIONS ITEM DESCRIPTION Power Requirements 120 Volts 60 Hertz Single phase 3 wire grounded Power Consumption 1030W Appr
4. supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord Where a two pronged wall receptacle is encountered it is the personal responsibility and obligation of the customer to contact a qualified electrician and have it replaced with a properly grounded three pronged wall receptacle or have a grounding adapter properly grounded and polarized If the extension cord must be used it should be a 3 wire 15 amp or higher rated cord Do not drape over a countertop or table where it can be pulled on by children or tripped over accidentally 4 http dc 136 4shared com doc xqap_LFD preview html 3 25 2012 120DP TXT Page 7 of 10 R 120DB R 120DK R 120DR R 120DW Grounded Receptacle Box CAUTION DO NOT UNDER ANY CIRCUMSTANCES CUT OR RE MOVE THE ROUND GROUNDING PRONG FROM THIS PLUG ia Grounding Pin 3 Pronged Receptacle OVEN DIAGRAM Oven door with see through window 2 Safety door latches The oven will not operate unless the door is securely closed Door hinges Door seals and sealing surfaces Door handle Pull to the open Turntable motor shaft Removable turntable support Removable turntable Place to turntable on the turntable support securely The turntable will rotate clockwise or counterclockwise Only remove for cleaning aew g No 9 Ventilation openings Rear 10 Oven light It will light when oven is operating 11 Wave guide co
5. 120DP TXT Page 1 of 10 R 120DB R 120DK R 120DR R 120DW SHARP SERVICE MANUAL 3007R120DPW MICROWAVE OVEN moves RR 120DB R 120DK R 120DR R 120DW In the interest of user safety the oven should be restored to its original condition and only parts identical to those specified should be used WARNING TO SERVICE PERSONNEL Microwave ovens con tain circuitry capable of producing very high voltage and current contact with following parts may result in a severe possibly fatal electrical shock High Voltage Capacitor High Voltage Power Transformer Magnetron High Voltage Recti fier Assembly High Voltage Harness etc TABLE OF CONTENTS PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY INSIDE FRONT COVER BEFORE SERVICING INSIDE FRONT COVER WARNING TO SERVICE PERSONNEL MICROWAVE MEASUREMENT PROCEDURE FOREWORD AND WARNING PRODUCT SPECIFICATIONS GENERAL INFORMATION OPERATION TROUBLESHOOTING GUIDE TEST PROCEDURE TOUCH CONTROL PANEL COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE PICTORIAL DIAGRAM CONTROL PANEL CIRCUIT PRINTED WIRING BOARD PARTS LIST PACKING AND ACCESSORIES This document has been published to be used for after SHARP CORPORATION sales service only The contents are subject to change without notice http dc 136 4shared com doc xqap_LFD preview html 3 25 2012 120DP TXT Page 2 of 10 R 120DB R 120DK R 120DR
6. R 120DW PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY a Do not operate or allow the oven to be operated with the door open b Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source and make repairs as necessary 1 interlock operation 2 proper door closing 3 seal and sealing surfaces arcing wear and other damage 4 damage to or loosening of hinges and latches 5 evidence of dropping or abuse c Before turning on microwave power for any service test or inspection within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections d Any defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is released to the owner e A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner BEFORE SERVICING Before servicing an operative unit perform a microwave emission check as per the Microwave Measurement Procedure outlined in this service manual If microwave emissions level is in excess of the specified limit contact SHARP ELECTRONICS CORPORATION immedia
7. SEMBLY TURNTABLE MOTOR The turntable motor rotates the turntable located on the bottom of the oven cavity so that the food on the turntable is cooked evenly The turntable may turn in either direction COOLING FAN MOTOR The cooling fan motor drives a blade which draws external cool air This cool air is directed through the air vanes surrounding the magnetron and cools the magnetron This 3 25 2012 120DP TXT R 120DB R 120DK R 120DR R 120DW air is channelled through the oven cavity to remove steam and vapours given off from the heating foods It is then exhausted through the exhausting air vents at the oven cavity MAGNETRON THERMAL CUT OUT The thermal cut out located on the air duct is designed to prevent damage to the magnetron if an over heated condi tion develops in the tube due to cooling fan failure ob structed air guide dirty or blocked air intake etc Under normal operation the thermal cut out remains closed However when abnormally high temperatures are reached within the magnetron the thermal cut out will open at 203 F 95 C causing the oven to shut down The thermal cut out will reset automatically below approximately 167 F 75 C Page 10 of 10 C T FUSE 1 The C T fuse blows when the contacts COM NO of the primary interlock relay RY2 and secondary interlock switch remain closed with the oven door open and when the monitor switch closes 2 If the wire harness or electrical compone
8. e display will show flashing 88 88 To set any program or set the clock you must first touch the STOP CLEAR pad The display will clear and will appear COOKING CONDITION Open the door Program desired cooking time by touching the NUMBER pads And program the power level by touch ing the POWER LEVEL pad and then a Number pad When close the door and the START pad is touched the following operations occur 1 The contacts of the relays are closed and components connected to the relays are turned on as follows For details refer to Figure O 2 RELAY CONNECTED COMPONENTS RY 1 oven lamp turntable motor fan motor RY 2 power transformer 2 120 volts A C is supplied to the primary winding of the power transformer and is converted to about 3 5 volts A C output on the filament winding and approximately 2000 volts A C on the high voltage winding 3 The filament winding voltage heats the magnetron SCHEMATIC NOTE CONDITION OF OVEN 1 DOOR CLOSED 2 CLOCK APPEARS ON DISPLAY 120V AC 60 Hz OL C T FUSE 0 RY 1 4 RY 2 a E PRIMARY 1 CONTROL UNIT OVEN LAMP filament and the H V winding voltage is sent to a voltage doubler circuit 4 The microwave energy produced by the magnetron is channelled through the waveguide into the cavity feed box and then into the cavity where the food is placed to be cooked 5 Upon completion of the cooking time the power transformer oven lam
9. e ovens should not be run empty To test for the presence of microwave energy within a cavity place a cup of cold water on the oven turntable close the door and set the power to HIGH and set the microwave timer for two 2 minutes When the two minutes has elapsed timer at zero carefully check that the water is now hot If the water remains cold carry out Before Servicing procedure and re examine the connections to the component being tested When all service work is completed and the oven is fully assembled the microwave power output should be checked and a microwave leakage test should be carried out 3 25 2012 120DP TXT Page 4 of 10 R 120DB R 120DK R 120DR R 120DW MICROWAVE MEASUREMENT PROCEDURE A Requirements 1 Microwave leakage limit Power density limit The power density of microwave radiation emitted by a microwave oven should not exceed 1mW cm_ at any point 5cm or more from the external surface of the oven measured prior to acquisition by a purchaser and thereafter through the useful life of the oven 5 mW cm at any point 5cm or more from the external surface of the oven 2 Safety interlock switches Primary interlock relay and door sensing switch shall prevent microwave radiation emission in excess of the requirement as above mentioned secondary interlock switch shall prevent microwave radiation emission in excess of 5 mW cm at any point 5cm or more from the external surface of the oven B Preparati
10. mary interlock system con sists of the door sensing switch and primary interlock relay located on the control circuit board MONITOR SWITCH The monitor switch is activated the contacts opened by the latch head on the door while the door is closed The switch http dc136 4shared com doc xqap_LFD preview html is intended to render the oven inoperative by means of blowing the C T fuse when the contacts of the primary interlock relay RY2 and secondary interlock switch fail to open when the door is opened Functions 1 When the door is opened the monitor switch contacts close to the ON condition due to their being normally closed At this time the primary interlock relay RY2 and secondary interlock switch are in the OFF condition contacts open due to its being normally open contact switches 2 As the door goes to a closed position the monitor switch contacts are first opened and then the door sensing switch and secondary interlock switch contacts close 3 If the door is opened and the primary interlock relay RY2 and the secondary interlock switch contact fail to open the C T fuse blows simultaneously with closing of the monitor switch contacts CAUTION BEFORE REPLACING A BLOWN C T FUSE TEST THE DOOR SENSING SWITCH PRI MARY INTERLOCK RELAY RY2 SECOND ARY INTERLOCK SWITCH AND MONITOR SWITCH FOR PROPER OPERATION RE FER TO CHAPTER TEST PROCEDURE NOTE C T FUSE AND MONITOR SWITCH ARE REPLACED AS AN AS
11. necessary to connect the power supply cord after the outer case has been removed in this event 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4 Disconnect the leads to the primary of the power transformer 5 Ensure that the leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedure reconnect the power supply cord When the testing is completed Open the door and block it open Discharge high voltage capacitor Reinstall the outer case cabinet NOOR WD Run the oven and check all functions http dc 136 4shared com doc xqap_LFD preview html Disconnect the power supply cord and then remove outer case Reconnect all leads removed from components during testing Reconnect the power supply cord after the outer case is installed 3 25 2012
12. nts are short circuited this C T fuse blows to prevent an electric shock or fire hazard 3 The C T fuse located on the top of the oven cavity is designed to prevent damage to the oven by fire If the food load is overcooked by either error in cook time or defect in the timer the C T fuse will open Under normal operation the C T fuse remains closed However when abnormally high temperatures are reached within the oven cavity the C T fuse will open at 248 F 120 C causing the oven to shut down or when the electric currents beyond 13A flow the C T fuse will open TROUBLESHOOTING GUIDE Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected When troubleshooting the microwave oven it is helpful to follow the Sequence of Operation in performing the checks Many of the possible causes of trouble will require that a specific test be performed These tests are given a procedure letter which will be found in the Test Procedure section IMPORTANT If the oven becomes inoperative because of a blown C T fuse check the monitor switch primary interlock relay RY2 door sensing switch and secondary interlock switch before replacing the C T fuse If the C T fuse is replaced the monitor switch must also be replaced Use part FFS BA027WRKZ as an assembly IMPORTANT Whenever troubleshooting is performed with the power supply cord disconnected It may in some cases be
13. on for testing Before beginning the actual measurement of leakage proceed as follows 1 Make sure that the actual instrument is operating normally as specified in its instruction booklet Important Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for microwave ovens 21 CFR 1030 10 c 3 i must be used for testing 2 Place the oven tray in the oven cavity 3 Place the load of 275 15 ml 9 8 oz of tap water initially at 20 TRT 68 F in the center of the oven cavity The water container shall be a low form of 600 ml 20 oz beaker with an inside diameter of approx 8 5 cm 8 1 2 in and made of an electrically nonconductive material such as glass or plastic The placing of this standard load in the oven is important not only to protect the oven but also to insure that any leakage is measured accurately 4 Set the cooking control on Full Power Cooking Mode 5 Close the door and select a cook cycle of several minutes If the water begins to boil before the survey is completed replace it with 275 ml of cool water C Leakage test Closed door leakage test microwave measurement 1 Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven 2 Move the probe slowly not faster than 1 in sec 2 5 cm sec along the gap watching for the maximum indication on the meter 3 Check for leakage at the door screen
14. ox 9 Amperes Power Output 600 W nominal of RF microwave energy IEC Test procedure Operating frequency 2450 MHz Case Dimensions Width 1 4 3 8 Height 14 1 8 Depth 14 Cooking Cavity Dimensions Width 1 1 3 4 0 7 Cubic feet Height 16 Depth 11 7 8 Control Complement Touch Control System Clock 1 00 12 59 Timer 0 99 minutes 45 seconds POPCORN pad EXPRESS DEFROST pad COMPU COOK pad DOUBLE QUANTITY pad STOP CLEAR pad STOP CLEAR button CLOCK TIMER pad 10 MINUTES pad 1 MINUTE pad 15 SECONDS pad START MINUTE PLUS button Yes Safety Standard UL Listed FCC Authorized DHHS Rules CFR Title 21 Chapter 1 Subchapter J GENERAL INFORMATION GROUNDING INSTRUCTIONS This oven is equipped with a three prong grounding plug It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current WARNING Improper use of the grounding plug can result in a risk of electric shock Electrical Requirements The electrical requirements are a 115 120 volt 60 Hz AC only 15 or 20 amp fused electrical supply It is recommended that a separate circuit serving only this appliance be provided When installing this appliance observe all applicable codes and ordinances A short power
15. p etc are turned off and the generation of microwave energy is stopped The oven will revert to the OFF condition 6 When the door is opened during a cook cycle the monitor switch door sensing switch secondary interlock switch and primary interlock relay are activated with the following results The circuits to the oven lamp turntable motor the cooling fan motor and the high voltage components are de energized and the digital read out displays the time still remaining in the cook cycle when the door was opened 7 The monitor switch is electrically monitoring the operation of the secondary interlock switch and primary interlock relay RY2 and is mechanically associated with the door so that it will function in the following sequence 1 When the door opens from the closed position the secondary interlock switch door sensing switch and primary interlock relay RY2 open their contacts Then the monitor switch contacts close 2 When the door is closed from the open position the monitor switch contacts open first Then the contacts of the secondary interlock switch and door sensing switch close If the secondary interlock switch and primary interlock relay RY2 fail with the contacts closed when the door is opened the closing of the monitor switch contacts will form a short circuit through the C T fuse secondary interlock switch and primary interlock relay RY2 causing the C T fuse to blow MAGNETRON THERMAL CUT OUT
16. sheet metal seams and other accessible positions where the continuity of the metal has been breached eg around the switches indicator and vents While testing for leakage around the door pull the door away from the front of the oven as far as is permitted by the closed latch assembly 4 Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW cm and that the secondary interlock switch does turn the oven OFF before any door movement NOTE After servicing record data on service invoice and microwave leakage report http dc 136 4shared com doc xqap_LFD preview html 3 25 2012 120DP TXT SERVICE MANUAL SHARP MICROWAVE OVEN R 120DB R 120DK R 120DR R 120DW FOREWORD This Manual has been prepared to provide Sharp Electronics Corp Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVEN R 120DB R 120DK R 120DR R 120DW lt is recommended that service personnel carefully study the entire text of this manual so that they will be qualified to render satisfactory customer service Check the interlock switches and the door seal carefully Special attention should be given to avoid electrical shock and microwave radiation hazard WARNING Never operate the oven until the following points are ensured A The door is tightly closed B The door brackets and hinges are not defective C The door packing is not damaged D The door is
17. tely 1 800 237 4277 If the unit operates with the door open service person should 1 tell the user not to operate the oven and 2 contact SHARP ELECTRONICS CORPORATION and Food and Drug Administration s Center for Devices and Radiological Health immediately Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit found with emissions in excess of 4mW cm The owner of the unit should be instructed not to use the unit until the oven has been brought into compliance http dc 136 4shared com doc xqap_LFD preview html 3 25 2012 120DP TXT Page 3 of 10 R 120DB R 120DK R 120DR R 120DW WARNING TO SERVICE PERSONNEL Don t Touch Danger High Voltage Microwave ovens contain circuitry capable of pro ducing very high voltage and current contact with following parts may result in a severe possibly fatal electrical shock Example High Voltage Capacitor High Voltage Power Trans former Magnetron High Voltage Rectifier Assem bly High Voltage Harness etc Read the Service Manual carefully and follow all instructions Before Servicing 1 Disconnect the power supply cord outer case 2 Open the door and block it open 3 Discharge high voltage capacitor and then remove WARNING RISK OF ELECTRIC SHOCK DISCHARGE THE HIGH VOLTAGE CAPACITOR BEFORE SERVICING The high voltage capacitor remains charged about 60 seconds after the oven has been switched off Wait for 60 seconds
18. ver DO NOT REMOVE 12 Control panel display 13 Start Minute Plus button 14 Stop Clear button TOUCH CONTROL PANEL pup e ae oS EXPRESS COMPUCOOK GUIDE POPCORN H A R P oe 1 Pizza 1 2 slices orousel 2 Coffee Tea 1 2 cups k STOP COMPU DOUBLE i CLOCK i F CLEAR COOK QUANTITY TIMER 3 Rolls Muffins 1 2 medium size i ag i Ad 4 Casseroles 1 2 cups ON DEF LBS QTY CHECK 10 1 Z 15 5 Frozen Entree 3 6 or 8 10 ounces MINUTES MINUTE SECONDS 6 Baked Potates 1 2 medium size Control panel display Wards will light in the display to indicate feature and cooking instructions NOTE 1 Open the door to program the oven 2 The STOP CLEAR and the START MINUTE PLUS pads can be used even if the door closed 3 MINUTE PLUS feature is disabled after one minute when the oven is not in use This feature is automatically enabled when the door is opened and closed or the STOP CLEAR pad is pressed http dc 136 4shared com doc xqap_LFD preview html 3 25 2012 120DP TXT R 120DB R 120DK R 120DR R 120DW Page 8 of 10 OPERATION DESCRIPTION OF OPERATING SEQUENCE The following is a description of component functions during oven operation OFF CONDITION Closing the door activates the door sensing switch and secondary interlock switch In this condition the monitor switch contacts are opened When the oven is plugged in 120 volts A C is supplied to the control unit Figure O 1 1 Th