Home
1000-MR2 - Alto
Contents
1. Mobile Refrigerated Cart Double Compartment 1000 MR2 INSTALLATION OPERATION MAINTENANCE 22 Your Service Hotline 1 800 558 8744 W164 N9221 Water Street 450 Menomonee Falls Wisconsin 53052 0450 USA PHONE 262 251 3800 800 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY www alto shaam com PRINTED IN U S A 8411 08 13 ITEM NO 1000 MR2 MOBILE REFRIGERATED CART ALTO SHAAM e The Alto Shaam Mobile refrigerated Cart is not just refrigerator on wheels but a well designed and efficient system for storing and transferring refrigerated food products e Adjustable shelves allow for the storage of plated items pans or other items e Full perimeter stainless steel bumper transport handles heavy duty casters along with the cart s reduced height provide easy mobility e Electronic thermostat has digital display to view inside set air temperature e Non magnetic stainless steel surface resists corrosion e Environmentally safe refrigerant e All mechanical equipment is easily accessible without the use of tools for ease in servicing e Center mounted cooling coil balances and distributes air evenly e Condensate from the cooling coil is used to cool the compressor therefore it is unnecessary to have an alternate means of water disposal Double cavity model with 20 gauge non magnetic stainless steel exterior and door fu
2. www alto shaam com PRINTED IN U S A 5 DUE TO ONGOING PRODUCT IMPROVEMENT SPECIFICATIONS ARE SUBJECT CHANGE WITHOUT NOTICE 411 08 13 amp AutoQuotes 2 EE E E CN A On E M E 9 amp amp X 1 N 0 N N bw 7 N m ud rt 67 1 2 1715mm with bumper 64 1 2 1638mm 29 1 2 749mm 2 1 2 64mm 68 1 2 1740mm 55 1 2 1410mm CLEARANCE REQUIREMENTS Full perimeter bumper accommodates all clearance requirements 693 22 Ib 315 10 kg NET 557 22 lb 253 10 kg CARTON DIMENSIONS LxwxH 31 15 16 x 42 3 4 x 70 7 8 810mm x 1085mm x 1800mm ALTO SHAAM 411 08 13 1000 MR2 MOBILE REFRIGERATED CART DIMENSIONS HxWxD EXTERIOR 68 1 2 x 67 1 2 x 29 1 4 1740mm x 1715mm x 742mm INTERIOR PER COMPARTMENT 21 1 4 x 27 1 4 x 55 1 2 540mm x 692mm x 1410mm VOLTAGE PHASE CYCLE HZ AMPS kW CORD amp PLUG 220 240 6 27 1 5 TIS 166 2549 PRODUCT PAN CAPACITY 504 Ib 229 kg MAXIMUM VOLUME MAXIMUM 315 QUARTS 399 LITERS GASTRONORM 1 1 530mm x 325mm x 65mm FULL SIZE PANS Fourty two 42 20 x 12 x 2 1 2 FULL SIZE SHEET PANS Twenty six 26 18 x 26 x 1 ON WIRE SHELVES ONLY ADDITIONAL SHELVES REQUIRED INSTALLATION REQUIREMENTS Cart must be installed level Cart must not be installed in
3. INACTIVITY This unit is designed for continued use at automatically cycled intervals case of an extended shut down the food storage Activate system by electrical service cord into electrical supply source Turn power switch to the ON position With the door closed and the storage area empty of product wait for a period of 1 hour Verify correct operating temperature Begin stocking the containment The compressor should immediately come on line and the evaporator fan activate The temperature in the storage area will begin to decrease Cabinet will have reached the proper operating temperature of 36 F 3 F 2 C 1 C area when the proper compartment must be cleaned and wiped dry to minimize the potential of odor build up during shutdown operating temperature has been reached ds el gt 3 4 ERROR CODES ALARM SIGNALS MESSAGE CAUSE OUTPUTS Compressor output P1 Room probe failure 29 13 7 and Third probe failure Outputs unchanged 2 Fourth probe failure Outputs unchanged Maximum 1000 MR2 temperature alarm Outputs unchanged Minimum WHITE BUMPER LA temperature alarm Outputs unchanged e MM Condenser high It depends on the 64 31 64 163800 2 temperature Ac2 parameter It depends on the bLL parameter Compressor according to rr
4. Menomonee Falls Wisconsin 53052 0450 U S A PHONE 262 251 3800 800 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY www alto shaam com PRINTED IN U S A
5. any area where it may be affected by steam grease dripping water extreme temperatures or any other severely adverse conditions OPTIONS amp ACCESSORIES Plate Carriers CONTACT FACTORY FOR CAPACITY DUE TO ONGOING PRODUCT IMPROVEMENT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Covered C Carriers Covered EC Carriers Uncovered P Carriers Uncovered EP Carriers Shelves 26 7 8 x 19 5 8 683mm x 498mm Powder Coated www alto shaam com DC 2869 DC 23676 DC 2868 DC 23580 SH 35956 W164 N9221 Water Street P O Box 450 Menomonee Falls Wisconsin 53052 0450 U S A PHONE 262 251 3800 800 558 8744 U s A CANADA FAX 262 251 7067 800 329 8744 U S A ONLY PRINTED IN U S A 5 ALTO SHAAM MOBILE REFRIGERATED CARTS 1 0 INTRODUCTION This technical manual provides information on the installation operation maintenance and inspection of this unit A complete parts breakdown is provided 1 1 EQUIPMENT DESCRIPTION The unit consists of the following Storage compartment The insulated food storage compartment is clear storage area Included in this area are the adjustable shelves and cooling coil Doors Access to the storage compartment is through a hinged mounted insulated door Condensing unit Compartment This area contains the condensing unit along with the necessary controls Evaporator Coil The evaporator coil is located in the stora
6. INA DNISNAIGNOO SLYUVd HOIAWAS Parts Identification PRINCIPAL mm UNCONIR I SEES Cor pressi Tube amp z5 Q D gl Tube 5 25 EA Suctiog Tube B25 Compressor for MR2 SCHEMATIC WIRING DIAGRAM C S R ELECTRICAL DIAGRAM QNnOSS NVJ ONOO JOSSdHdWOO i r ZHO9 0S A0EZ MS WOO poe 2 Xlddf S m e e o AOGZv 8 0Z A3M 10H verie6 v1391 Xd oue CMIN LSVO Q31v339lJJ3M JIGOW X04 WVYOVIG 9NISIM ZHOS A0ZZ AlddN dd 1 13 14 1000 MR2 60HZ OPERATION MANUAL 708 13 TRANSPORTATION DAMAGE and CLAIMS Alto Shaam equipment is sold F O B shipping point and when accepted by the carrier such shipments become the property of the consignee Should damage occur in shipment it is a matter between the carrier and the consignee In such cases the carrier is assumed to be responsible for the safe delivery of the merchandise unless negligence can be established on the part of the shipper 1 Make an immediate inspection while the equipment is still in the truck or immediately after it is moved to the receiving area Do not wait until after the material is moved to a storage area Do not sign a delivery receipt or a freight bill until you have made a proper count and inspection of all merchandise received 2 3 Note all damage to packages directly on the carr
7. about 5 minutes Re enter the initial set point value 1000 MR2 60HZ OPERATION MANUAL 208 13 7 1 FILTER DRYER REPLACEMENT 1 Close liquid line valve and run compressor until the low side refrigeration gauge indicates 0 pounds Close suction valve 2 If the system is slightly pressurized open both manifold gauge valves and purge the service gauge lines 3 With manifold gauge valves closed start the refrigeration system 4 Attach a drum of R134A refrigerant to the suction service side of the manifold gauges and add refrigerant through the suction side until the liquid sight glass is clear of bubbles A DANGER DISCONNECT UNIT FROM POWER SOURCE BEFORE CLEANING OR SERVICING 8 14 MR2 60Hz SERVICE PARTS DESCRIPTION QTY PART NUMBER RUBBER WHEEL 5 QTY PART NUMBER 13402 191115 ROLLER BRAKE 13510 RUBBER WHEEL 5 146014 191154 FIX 1128225 COMP 220V 60Hz 1154459 O4URALTO2DB001 qM Bane ee 5 5 09 2 5 9 6 a Fa e m 2 g 2 2 2 5 15 5 5 2 5 7 Z COND COIL 1 0149 2541011 PVC Shelf 498 x 683 COND FAN MOTOR 0091041 1105009 Complete set 009147 DRAIN HOT GAS 048102 990120 Door Hing 1811 Evaporator coil 26515512 Door Latch Handle 110835 Evaporator fan motor 11009109 0 3840 Power Control Switch 1099115 08 4002CX BES BE LT 1 w
8. any cleaning agent other than Alto Shaam s Combitherm Cleaner including but not limited to damage due to chlorine or other harmful chemicals Use of Alto Shaam s Combitherm Cleaner on Combitherm ovens is highly recommended 7 Any losses or damage resulting from malfunction including loss of product food product revenue or consequential or incidental damages of any kind 8 Equipment modified in any manner from original model substitution of parts other than factory authorized parts removal of any parts including legs or addition of any parts This warranty is exclusive and is in lieu of all other warranties express or implied including the implied warranties of merchantability and fitness for a particular purpose In no event shall Alto Shaam be liable for ALT HA AM loss of use loss of revenue or profit or loss of product or for any indirect special incidental or consequential damages No person except an officer of Alto Shaam Inc is authorized to modify this warranty or to incur on behalf of Alto Shaam any other obligation or liability in connection with Alto Shaam equipment Effective November 1 2012 RECORD THE MODEL AND SERIAL NUMBER OF THE APPLIANCE FOR EASY REFERENCE ALWAYS REFER TO BOTH MODEL AND SERIAL NUMBER IN ANY CONTACT WITH ALTO SHAAM REGARDING THIS APPLIANCE Mode Datelnstadled Voltage BEDV Purchased From Serial Number W164 N9221 Water Street P O Box 450
9. d Condenser low LA2 temperature External alarm Output unchanged Serious external alarm i1F bAL Pressure switch alarm i1F PAL All outputs OFF All outputs OFF CA amp B l 074 me DANGER ENSURE POWER SOURCE MATCHES VOLTAGE STAMPED ON APPLIANCE NAMEPLATE 1000 MR2 60HZ OPERATION MANUAL 08 13 2 14 OPERATION CLEANING 4 0 OPERATING PROCEDURE The purpose of this mobile refrigerator is to maintain cold foods at proper serving temperatures The unit should the intended purpose only a Adjust the position of the shelves accommodate required storage needs b Switch the power to the ON position Pre chill the cabinet to the full factory preset temperature of 36 F 3 F 2 C d Load the refrigerator with chilled foods only Before loading use a food thermometer to make certain all products are at a temperature of 41 F 5 C maximum or less Cover foods to reduce moisture build up on the inside wall of the cabinet To maintain the proper refrigerated food temperature open the door only when necessary The mobile refrigerated door may be locked if required 5 0 CLEANING and MAINTENANCE A thorough periodic maintenance schedule is required to ensure the longest and most trouble free operation Maintenance schedules should be aimed at maximizing the efficient use of maintenance personnel reducing down time and providing the orderly acquisi
10. e 1 I e NO NO NO CO 3 lt UJ Q gt lt EE ex 5697 3 eo 5 2 i 21 o lolo o a 1000 MR2 60HZ OPERATION MANUAL 7208 13 9 14 89X86F ATAHS AVAA NATION 51 WAGGA XIA STI4HA WAGE o mu LAS ALATANOD 6005011 YOLOW NVA YaASNAGNOD TOO YWASNAGNOOD HOLV I HOLIMS IO LLNOO WAMOd 1 TV LIDIG NVA mno TOO SHO LV9IOd VAS asss oro CH09 CNIW SLYVd 32IAWAS WV 17 51 01 10c L 8 84Np ZH09 C INOg WVVHS 16102 TVANVI NVHDOIA E 107 219 WV LE L1 01 10c L 8 84p ZH09 c INOg WVVHS OLTVVCHIANELOCLHOTSIdONELOC TVANVI NVHDOIA E 107 S A KV S 5 L M oy Mes 4 N LAS ALWTId NOD 600SOTI t YUOLOW NVA WASNAGNOD WOO WASNAGNOOD 110175 HOSST HdIWOO 6srvSII NOLLdTWOS 1G SPI IN LIV d ON WALI CH09 CXNW L
11. e to the door 6 7 DOOR GASKET REPLACEMENT To install the replacement hinge NOTE It is suggested that the door be removed from the cabinet and placed face down on a work table Remove the fasteners and pull old gasket from the retainer reverse the process 6 9 POWER SWITCH REPLACEMENT 1 Disconnect the unit from the power source Clean gasket retainer and immediate 2 Remove the silicone seal around the area perimeter of the front control leader Start new gasket into retainer After panel gasket is positioned replace fasteners Remove the panel by lifting straight up 3 Using a flat blade screwdriver remove NOTE Avoid cutting the gasket if possible the cover plate with switch attached 4 Remove the wires connected to the switch 5 Unscrew the lock washer and remove the switch 6 Reverse the process to install the new switch 7 Remount the panel and reseal the 1000 MR2 60HZ OPERATION MANUAL 08 13 silicone A DANGER DISCONNECT UNIT FROM POWER SOURCE BEFORE CLEANING OR SERVICING 5 14 CORRECTIVE MAINTENANCE TROUBLE SHOOTING GUIDE Unit does not cool Bad connection at supply Check supply cord at cord outlet IIl fitting gasket Tighten strike on door latch Low refrigerant Check system for leaks and recharge Unit does not operate Control failure Adjust control or replace Incorrect voltage Supply correct voltage Bad connection at supply Replace or repair cord Fail
12. ed compressor Replace Unit runs continuously Low on Refrigerant Leak check system and recharge Control failure Adjust control or replace Restricted air flow or Rectify air flow problem dirty condenser coil and clean condenser Bad condenser fan Check and replace if motor necessary Compressor failure Replace Ineffective door seal Adjust door strike Air circulation in storage Redistribute food and restricted even air flow Low head pressure Defective compressor Replace Low refrigerant Leak check system and recharge Ambient temperature too Redistribute food for low even air flow High head pressure Blocked or dirty Clean and remove any condenser obstructions Ambient temperature too Improve room high temperature System contains air Evacuate change the filter dryer and recharge Refrigerant overcharge Reduce refrigerant in the system Short cycling Mal adjusted control e Adjust control This chart is provided for the assistance of qualified technicians only and is not intended for use by untrained or unauthorized service personnel A DANGER DISCONNECT UNIT FROM POWER SOURCE BEFORE CLEANING OR SERVICING 1000 MR2 60HZ OPERATION MANUAL 208 13 6 14 CORRECTIVE MAINTENANCE TROUBLE SHOOTING GUIDE SERVICE N using standard procedures The skill level required to perform these CAUTION repairs vary Some require specific training and are not intended for use by untrained or unauthoriz
13. ed service personnel Procedures requiring refrigerant handling require certification If your unit is not operating properly contact Alto Shaame for the nearest authorized service agent These are the only service agents the company will authorize to repair Alto Shaame units Repairs made by any other service agents without prior authorization by Alto Shaame will void the warranty on the unit FEDERAL LAWS REQUIRE PROPER HANDLING AND DISPOSAL OF REFRIGERANT CAUTION IT 15 UNLAWFUL TO VENT ANY REFRIGERANT INTO THE ATMOSPHERE Alto Shaam Inc urges all individuals responsible for training teaching or advising installation mechanics and service personnel to emphasize proper handling and charging techniques and strict adherence to limiting refrigerant charge amount to those specifically recommended by the manufacturers of refrigeration air conditioning or heat pump systems DANGER POWER SOURCE BEFORE CLEANING OR SERVICING 1000 MR2 60HZ OPERATION MANUAL 08 13 7 14 CORRECTIVE MAINTENANCE TROUBLE SHOOTING GUIDE 7 0 THERMOSTAT REPLACEMENT 1 Disconnect the unit from the power source 2 Remove the front contro panel disconnect the electrical terminals 3 exerting correct strength slide the brackets from the rear of the control panel 4 Remove the defective digital thermostat controller and replace with a new controller 5 Start the system Allow the system to operate for
14. er appears 2 To display the set point value press the SET key again The value appears on the display 3 Tochange the set point value use the UP and DOWN key within 15 seconds 6 4 CONDENSER FAN amp MOTOR REPLACEMENT 1 Disconnect all electrical power to the unit Remove the ventilation grill Remove the mounting bolts on the condensing unit base slide the refrigeration assembly out 4 Remove the protective shroud from around the motor o Remove the mounting screws at the motor base 6 Using an allen wrench loosen the set screw on the blade hub and slide blade from the shaft 7 Install the new condenser fan by reversing the process 8 Install the motor by reversing the process DANGER DISCONNECT UNIT FROM POWER SOURCE BEFORE CLEANING OR SERVICING 4 14 SCHEDULED MAINTENANCE 6 8 DOOR HINGE REPLACEMENT NOTE This procedure will require two 6 6 DOOR HANDLE REPLACEMENT NOTE may be necessary to remove the handle assembly in order to get the cabinet through a door opening Remove the three side mounting screws in latch Remove two screws in strike people One person to hold the door while the other removes the attachment screws Using a screwdriver remove the three screws which attach the butt section of the hinges to the cabinet Replace in reverse order 2 With the door detached from the cabinet remove the screws which attach the second part of the hing
15. ge compartment and is responsible for distributing the cold air associated with the refrigeration system 1 2 EQUIPMENT SUPPLIED The unit is shipped from the factory fully assembled except the adjustable shelving that will require positioning on the side racks The complete assembly is palletized and crated to reduce the possibility of damage in shipping and storage 1 3 LEADING PARTICULARS Refrigerant R134a Electrical 1000 MR2 220 240VAC 60 Hz 12 6 3 Amps TIS166 2549 Net 557522 Ib 253 10kg Shipping 693422 Ib 315 10kg 1000 MR2 60HZ OPERATION MANUAL 208 13 2 0 FUNCTIONAL DESCRIPTION This unit is self contained automatically controlled continuous duty perishable food storage system It is designed with the intent and purpose of storing cold food items The operating temperature is automatically monitored by controls that are factory set to maintain a predetermined adequate condition The unit consists of two basic assemblies a Condensing Unit Compartment which includes the condensing unit the electrical control panel with power switch and terminal box and a heated condensation evaporator b Storage Compartment which consists of the insulated clear storage area for perishable food items requiring a temperature range of 37 to 40 F 3 to 4 C The clear storage area includes adjustable shelving 2 1 SYSTEM OPERATION The primary focus for the design of the refrigerated cabinet is for t
16. he safe storage of food products which require refrigeration Considerable engineering attention was placed on the qualities of function and serviceability The refrigeration system is a closed loop system Unless the system develops a leak adding additional refrigerant is not necessary 3 0 START UP PROCEDURE The refrigeration system is completely factory assembled pre charged and ready for operation The control has been set to display temperature in degrees Fahrenheit or degree Celsius as specified on the original order To energize the system it is only necessary to locate the power supply cord and connect it to a proper electrical supply source Once the supply cord has been connected to a power source the unit can be started by switching the power control switch to the ON position 3 1 SHUT DOWN PROCEDURE To shut down place the power control in the OFF position and open the door to allow the cabinet interior temperature to equalize with the room temperature Use a mild detergent diluted in warm water to wash the interior and exterior surfaces of the cabinet 1 14 PROCEDURES START UP PROCEDURE OPERATION RESULTS CONTROL AND INDICATION NAME Thermostat Power Control Switch ON OFF LCD display TYPE Contact Points Contact Points FUNCTION Cycles the refrigeration system automatic Terminates power to the unit Indicates continuous cabinet temperature 3 3 EXTENDED PERIOD OF
17. ier s delivery receipt 4 Make certain the driver signs this receipt If he refuses to sign make a notation of this refusal on the receipt 5 If the driver refuses to allow inspection write the following on the delivery receipt Driver refuses to allow inspection of containers for visible damage 6 Telephone the carrier s office immediately upon finding damage and request an inspection Mail a written confirmation of the time date and the person called 7 Save any packages and packing material for further inspection by the carrier 8 Promptly file a written claim with the carrier and attach copies of all supporting paperwork We will continue our policy of assisting our customers in collecting claims which have been properly filed and actively pursued We cannot however file any damage claims for you assume the responsibility of any claims or accept deductions in payment for such claims LIMITED WARRANTY Alto Shaam Inc warrants to the original purchaser only that any original part that is found to be defective in material or workmanship will at Alto Shaam s option subject to provisions hereinafter stated be replaced with a new or rebuilt part The original parts warranty period is as follows For the refrigeration compressor on Alto Shaam Quickchillers five 5 years from the date of installation of appliance For the heating element on Halo Heat cooking and holding ovens as long as the original purchaser owns the ove
18. lly insulated with high density foamed in place polyurethane Doors include two 2 positive door latches with magnetic mechanical closing and cylinder door lock 22 gauge non magnetic non corrosive stainless steel interior includes four 4 removable stainless steel side racks with 50 shelf positions spaced on 1 1 4 32mm centers six 6 powder coated shelves 26 1 2 x 21 3 4 673mm x 552mm The mobile refrigerator is controlled by one 1 ON OFF switch with a factory set temperature of 36 F 2 C A LED display monitors the inside temperature Unit includes one 1 transport handle on each end of the cart and a full perimeter stainless steel bumper guard Cart is furnished with removable side racks six 6 powder coated shelves six 6 5 127mm heavy duty casters two 2 rigid and four 4 swivel with brake and rear power cord storage during transport One 1 1 3 horsepower compressor system utilizes 134a refrigerant generating 2560 BTU per hour MODEL 1000 MR2 Double compartment Mobile Refrigerated Cart FACTORY INSTALLED OPTIONS e Temperature display in Fahrenheit is standard Specify degrees Celsius on order as required e Specify voltage requirement on order as required 115V 220V ALT HAAM W164 N9221 Water Street P O Box 450 Menomonee Falls Wisconsin 53052 0450 U S A PHONE 262 251 3800 800 558 8744 U s a CANADA FAX 262 251 7067 800 329 8744 U S A ONLY
19. n This excludes holding only equipment For all other original parts one 1 year from the date of installation of appliance or fifteen 15 months from the shipping date whichever Occurs first The labor warranty period is one 1 year from the date of installation or fifteen 15 months from the shipping date whichever occurs first Alto Shaam will bear normal labor charges performed during standard business hours excluding overtime holiday rates or any additional fees To be valid a warranty claim must be asserted during the applicable warranty period This warranty is not transferable THIS WARRANTY DOES NOT APPLY TO 1 Calibration 2 Replacement of light bulbs door gaskets and or the replacement of glass due to damage of any kind 3 Equipment damage caused by accident shipping improper installation or alteration 4 Equipment used under conditions of abuse misuse carelessness or abnormal conditions including but not limited to equipment subjected to harsh or inappropriate chemicals including but not limited to compounds containing chloride or quaternary salts poor water quality or equipment with missing or altered serial numbers 5 Damage incurred as a direct result of poor water quality inadequate maintenance of steam generators and or surfaces affected by water quality Water quality and required maintenance of steam generating equipment is the responsibility of the owner operator 6 Damage caused by use of
20. rol panel to the OFF position Disconnect the unit from the power source 6 1 MONTHLY INSPECTION amp SERVICE CHECK THE INLET AND OUTLET ENDS OF THE DRAIN LINE to make certain there are no obstructions If an obstruction is found Use compressed air to unblock an obstructed drain line in a forced air evaporator model Remove the drain line at the evaporator coil and attach an air line using 60 pounds of pressure The use of chemicals to clear a clogged drain is not recommended 6 2 YEARLY INSPECTION amp SERVICE 1 INSPECT THE DOOR GASKET for cracks splits and dryness 2 INSPECT THE MOVING PARTS OF THE DOOR LATCH assembly for signs of wear Check the screw tightness on both latch and strike 3 CHECK THE HINGES by opening the door to a 90 degree angle to the cabinet With minimum pressure lift up on the outer edge of the door Replace the hinges if there is an upward movement of 1 2 inch 12 7 or more 1000 MR2 60HZ OPERATION MANUAL 208 13 6 3 THERMOSTAT ADJUSTMENT Before making any adjustment to the thermostat check the door gasket for proper seal Proper adjustment can be tested by pulling a dollar bill through the gasket seal and feeling a slight resistance If it is determined a proper seal is maintained around the full perimeter of the gasket a thermostat adjustment may be necessary 1 Access the machine status menu by pressing and quickly releasing the SET key The label of the SET fold
21. tion of spare parts support 1000 MR2 60HZ OPERATION MANUAL 08 13 5 1 CLEANING Follow appropriate state and local health hygiene regulations regarding all applicable cleaning and to sanitation requirements for food service equipment DAILY Wipe all spills at once WEEKLY a Remove the wire shelves and side rack shelf supports Clean these items separately using a mild non abrasive detergent and soft cloth b With a mild non abrasive detergent and water use a soft cloth to wipe the interior liner of the storage compartment Begin at the top and work down Wipe the gasket surrounding the storage compartment opening C Using a mild detergent and water wipe the vinyl door gasket Make certain to wipe under the gasket to remove any mildew or residue d Wipe interior surfaces with a clean cloth and sanitizing solution for use on metal and vinyl food contact surfaces This is an important step to control the build up of unwanted mildew and mold on the evaporator coil and fan e Vacuum right left and back panel grill vents to maintain maximum air flow f Wipe the interior of the unit with a mild detergent and water Always wipe with the grain of the stainless steel to prevent scratching the finish DISCONNECT UNIT FROM IPOWER SOURCE BEFORE CLEANING OR SERVICING 3 14 SCHEDULED MAINTENANCE 6 0 MAINTENANCE Remember to de energize the unit by switching the toggle switch located on the cont
Download Pdf Manuals
Related Search
Related Contents
MODE D`EMPLOI - Support Manuel d`utilisation LG 29UM67-P Philips DVD-R DR4S6Q75F Gig Rig CompACT 10 Sub/Sat Speaker System MANUEL D`UTILISATION Bedienungsanleitung P4000 (pdf, 0,81MB, deutsch, englisch) Manuale del CDE Solaris per utenti esperti e amministratori di sistema Copyright © All rights reserved.